Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Eur Spine J ; 29(11): 2723-2733, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32865650

RESUMO

PURPOSE: Cervical disc arthroplasty (CDA) has become an increasingly popular treatment for cervical degenerative disc disease. One potential complication is osteolysis. However, current literature on this topic appears limited. The purpose of this study is to elucidate the incidence, aetiology, consequence, and subsequent treatment of this complication. METHODS: A systematic literature review was performed according to the PRISMA guidelines. Studies discussing the causes, incidence and management of osteolysis after a CA were included. RESULTS: A total of nine studies were included. We divided these studies into two groups: (1) large case series in which an active radiological evaluation for osteolysis was performed (total = six studies), (2) case report studies, which discussed symptomatic cases of osteolysis (total = three). The incidence of asymptomatic osteolysis ranged from 8 to 64%; however, only one study reported an incidence of < 10% and when this case was excluded the incidence ranged from 44 to 64%. Severe asymptomatic bone loss (exposure of the implant) was found in less than 4% of patients. Bone loss from osteolysis appeared to occur early (< 1 year) after surgery and late (> 1 year) as well. Symptomatic patients with osteolysis often required revision surgery. These patients required removal of implant and conversion to fusion in the majority of the cases. CONCLUSIONS: Osteolysis after CDA is common; however, the majority of cases have only mild or asymptomatic presentations that do not require revision surgery. The timing of osteolysis varies significantly. This may be due to differences in the aetiology of osteolysis.


Assuntos
Degeneração do Disco Intervertebral , Osteólise , Fusão Vertebral , Substituição Total de Disco , Artroplastia/efeitos adversos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Discotomia , Humanos , Degeneração do Disco Intervertebral/cirurgia , Osteólise/diagnóstico por imagem , Osteólise/epidemiologia , Osteólise/etiologia , Resultado do Tratamento
2.
Coluna/Columna ; 10(2): 144-147, 2011. graf, tab
Artigo em Português | LILACS | ID: lil-595889

RESUMO

OBJETIVO: Substitutos de enxerto ósseo autólogo foram desenvolvidos para evitar as complicações da retirada de enxerto ósseo autólogo. SiCaP (Actifuse, ApaTech EUA, Reino Unido) é um enxerto ósseo composto de cálcio-fosfato com um substituição de silicato na estrutura química, com uma estrutura tridimensional que parece osso natural. MÉTODOS: 19 pacientes foram submetidos à fusão óssea cervical e analisados retrospectivamente. A avaliação radiográfica e avaliação clínica foram realizadas utilizando o questionário Neck Disability Index e a escala análoga da dor (VAS) pré- e pós-operação. RESULTADOS: O período médio de acompanhamento pós-operatório foi de 14 meses ± 5 meses (7-30 meses). 11 pacientes foram submetidos à fusão via anterior; 5 pacientes via posterior e 3 pacientes via anterior e posterior. A revisão radiográfica mostrou 19/19 (100 por cento) de fusão óssea, nenhum caso apresentou subsidência, quebra ou soltura de material de implante ou movimento nos níveis fusionados. Nenhum exemplo de ossificação heterotópica ou de crescimento ósseo intracanal foi observado. Clinicamente, os escores médios do Neck Disability decresceram 13,3 pontos (media pré-op. de 34,5, pós-op. de 21,2, melhora de 39 por cento), a média da VAS para dor cervical decresceu 2 pontos (2,7 pré-op para 0,7 pós-op.; melhora de 74,1 por cento). Não foram observadas complicações como infecção, osteólise ou edema excessivo das partes moles. CONCLUSÃO: Os resultados preliminares obtidos nesta série foram encorajadores com o uso do SICaP como enxerto ósseo, com sólida fusão óssea obtida em todos os casos e sem formação de ossificação heterotópica ou crescimento de osso intracanal. SIcaP demonstra ser um substituto confiável para o enxerto ósseo autólogo na coluna cervical.


OBJECTIVE: Bone graft substitutes have been developed to obviate the need for autograft from the iliac crest and its resultant complications. SiCaP (Actifuse, ApaTech US, UK) is a calcium phosphate bone graft substitute with selective controlled silicate substitution in a patented 3-dimensional structure resembling natural bone. METHODS: 19 patients who underwent cervical spine fusion were retrospectively reviewed. Radiographic evaluation and clinical evaluation were performed using Neck Disability Index questionnaire and Visual Analog Scale (VAS) pre- and post-operatively. RESULTS: The mean post-operative follow-up was 14 ± 5 months, range 7-30 months. Eleven patients had an anterior approach, five patients had a posterior approach, and 3 had combined anterior-posterior approaches. Radiographic review showed 19/19 (100 percent) patients were considered fused, with no subsidence, hardware breakage, or hardware loosening. No instances of heterotopic bone formation or intracanal boney ingrowths were observed. Clinically, average Neck Disability scores decreased 13.3 points (pre-op 34.5, post-op 21.2, a 39 percent improvement); average VAS neck pain scores decreased 2.2 points (4.9 pre-op to 1.9 post-op; a 44.9 percent improvement; average VAS arm pain decreased 2.0 points (2.7 pre-op to 0.7 post-op, a 74.1 percent improvement). There were no complications such as infection, osteolysis, or abnormal swelling of soft tissues. CONCLUSIONS: Preliminary results from this series with the use of SiCaP bone graft substitute were encouraging, with solid fusion occurring in all subjects, and no heterotopic bone formation or intracanal bone ingrowths. SiCaP seems to be a reliable alternative to autograft on cervical spine fusion achieving solid fusion with no complications.


OBJETIVO: Sustitutos de injerto óseo autólogo fueron desarrollados para evitar las complicaciones de la recogida de injerto óseo autólogo. SiCaP (Actifuse, ApaTech EE.UU, Reino Unido) es un injerto óseo compuesto de calcio-fosfato con una sustitución de silicato en la estructura química, con una estructura tridimensional que parece hueso natural. MÉTODOS: 19 pacientes fueron sometidos a fusión ósea cervical y analizados retrospectivamente. La evaluación radiográfica y la evaluación clínica fueron realizadas utilizandose el cuestionario Neck Disability Index y la escala análoga del dolor (VAS) pre y postoperación. RESULTADOS: El período promedio de seguimiento postoperatorio fue de 14 meses ± 5 meses (7-30 meses). Once pacientes fueron sometidos a fusión vía anterior; 5 pacientes vía posterior y 3 pacientes vía anterior y posterior. La revisión radiográfica mostró 19/19 (100 por ciento) de fusión ósea, ningún caso presentó subsidencia, rotura o soltura de material de implante o movimiento en los niveles fusionados. Ningún ejemplo de osificación heterotópica o de crecimiento óseo intracanal fue observado. Clínicamente, el promedio de las puntuaciones del Neck Disability disminuyeron 13,3 puntos (promedio preop. de 34,5, postop. de 21,2, mejora de 39 por ciento), el promedio de VAS para dolor cervical disminuyó 2 puntos (2,7 preop. para 0,7 postop.; mejora de 74,1 por ciento). No fueron observadas complicaciones como infección, osteólisis o edema excesivo de las partes blandas. CONCLUSIÓN: Los resultados preliminares obtenidos en esta serie feuron estimulantes con el uso de SICaP como injerto óseo, con sólida fusión ósea obtenida en todos los casos y sin formación de osificación heterotópica o crecimiento de hueso intracanal. SIcaP demuestra ser un sustituto confiable para el injerto óseo autólogo en la columna cervical.


Assuntos
Humanos , Substitutos Ósseos , Cerâmica , Fusão Vertebral , Coluna Vertebral , Transplantes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA