Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
Iran Endod J ; 19(3): 189-192, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39086711

RESUMO

Introduction: Ultrasonic vibration for metallic post removal seems to be a unanimous choice between endodontists and general practitioners for providing the best results and having the highest safety. This study compared the time required by ultrasonic vibration for removing metallic post (MP) when 1 or 2 ultrasonics devices are used. Materials and Methods: One hundred and fifteen teeth with MPs from 105 patients, indicated for nonsurgical endodontic retreatment were divided into 2 groups according to the number of ultrasonic devices used (G1-1 device) and (G2-2 devices). In G1, the MP was worn with a transmetal bur, alongside the wear of the cement line (around 2 mm deep). Then, an ultrasonic tip attached to an ultrasonic unit, with a power of 100% was activated at the level of the post, with constant water spray at a level of 1 mm above the axial surface of the tooth. The position of the tip was changed between buccal and lingual surfaces every 10 seconds until the MP was removed. In G2 the same procedures were performed as described in G1, but two ultrasonic tips were activated simultaneously at buccal and lingual surfaces until the MP was removed. The vibration time necessary for removing each MP was recorded using a chronometer. Results: The mean time was 131.10±29.68 seconds (mean±standard error of the mean) for MP removal using one ultrasonic device, and 24.86±6.88 seconds for two devices. The time required for MP removal using two ultrasonic devices was significantly less than when using one ultrasonic device (P<0.001). Conclusion: The technique with 2 ultrasonic devices proved to be more efficient than the one using only 1 ultrasonic device.

2.
Prim Dent J ; 13(2): 53-57, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38888075

RESUMO

A technique is outlined for utilising a polymeric composite reinforced with glass fibres in a three-dimensional mesh as a post-core in aesthetic cases. The clinical procedure involves obtaining an impression of the root canal space, scanning the definitive cast, and milling a fibre-reinforced composite post-core. Subsequently, the intra-radicular post-core is cemented using an adhesive resin cement. The use of custom-made computer-aided design-computer-aided manufacturing (CAD-CAM) fibre-reinforced composite post-core facilitates repairability, provides better adaptation to the root canal space, avoids uneven cement thickness, ensures chemical adhesion to resin cement, and promotes favourable aesthetics when combined with all-ceramic crowns.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Vidro , Técnica para Retentor Intrarradicular , Humanos , Resinas Compostas/química , Vidro/química , Cimentos de Resina/química , Coroas , Estética Dentária , Retenção em Prótese Dentária , Materiais Dentários/química , Cimentação
3.
J Esthet Restor Dent ; 36(9): 1281-1300, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38563466

RESUMO

OBJECTIVE: This systematic review aimed to analyze the clinical (survival rate, failure risk, or fracture) and laboratory performance (fracture mode or failure) of rehabilitations of endodontically treated teeth, with and without posts. MATERIALS AND METHODS: A systematic search was conducted in the Pubmed, Scopus, Web of Science, Embase, Cochrane Library, and OpenGrey databases up to March 2023, according to PRISMA guidelines. In vitro and clinical studies that compared the clinical and laboratory performance of endodontically treated teeth with and without intraradicular posts were included. Studies selection, data extraction, and risk of bias analysis were performed. RESULTS: Thirty-one in vitro and 7 clinical studies were included. For in vitro studies, fiberglass post (n = 24) was the most mentioned. The follow-up time of the clinical studies ranged from 1 to 17 years, with the fiber-reinforced composite post (n = 3) being the most evaluated, and only failure risk proved to be more favorable for using intraradicular posts. CONCLUSION: Rehabilitations of endodontically treated teeth with and without intraradicular retainers showed no difference in fracture resistance and failure mode, evaluated by in vitro studies. Clinical studies showed no difference in survival rate, but failure risk proved to be more favorable for the use of posts. CLINICAL SIGNIFICANCE: This analysis revealed significant variability between results, however, most laboratory and clinical studies revealed no difference with using the post. Furthermore, it is important to emphasize the need to evaluate the coronary remnant and the general characteristics of the tooth in each situation.


Assuntos
Dente não Vital , Humanos , Técnica para Retentor Intrarradicular , Falha de Restauração Dentária , Fraturas dos Dentes
4.
J Esthet Restor Dent ; 36(2): 303-323, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37571973

RESUMO

OBJECTIVE: To assess and compare, through a systematic review of the literature, the biomechanical performance of endocrowns and traditional core-crowns (with and without intracanal post) for the rehabilitation of endodontically treated teeth with severe coronal structure damage. MATERIALS AND METHODS: A systematic search was performed in MEDLINE/PubMed, Scopus, and Web of Science databases. In-vitro studies comparing endocrowns with (post-)core-crown restorations were selected and screened by two independent reviewers. The included studies were submitted to the risk of bias analysis using the RoBDEMAT tool and the biomechanical outcomes were collected for qualitative analysis. The extracted data were presented based on comparative analyses among the included studies. RESULTS: Thirty-one studies were included: 9 studies evaluated restorations of molars, 14 for premolars, and 8 studies evaluated anterior restorations. For the majority of the studies, endocrowns showed either similar or greater survival rates under fatigue and monotonic load than (post-)core-crown restorations, irrespectively of the tooth. The endocrowns showed more favorable failure patterns than (post-)core-crowns, irrespectively of the tooth. Endocrowns produced lower stresses in the restorative material for molars and premolars and in the luting material for premolars than (post-)core-crown restorations. The included studies presented adequate information for most items of the RoBDEMAT risk of bias tool. CONCLUSION: Endocrowns showed similar or greater biomechanical performance than the traditional (post-)core-crown restorations in most of the evaluated studies. CLINICAL SIGNIFICANCE: This systematic review showed that endocrowns present either similar or greater biomechanical performance than core-crown restorations for anterior and posterior endodontically treated teeth with severe structural damage.


Assuntos
Coroas , Dente não Vital , Humanos , Materiais Dentários , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Dente não Vital/terapia , Prostodontia/métodos
5.
Braz. dent. sci ; 27(1): 1-11, 2024. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1537767

RESUMO

Objective: This systematic review aims to compare the clinical longevity of metallic and fiberglass intraradicular posts in teeth with severely compromised crowns, utilizing randomized clinical trials and case reports published in the last eleven years. Material and Methods: The research was conducted on PubMed, Medline, Lilacs, and BBO databases using the first search strategy with the descriptors 'dental posts,' 'longevity,' 'fiberglass-reinforced posts' or 'metallic posts.' The second search strategy involved analyzing the references of articles identified by the first search. Both studies were carried out with stringent inclusion and exclusion criteria. Results: No statistically significant and clinically relevant differences in longevity were observed between metallic and fiberglass posts. Conclusion: The clinical success and durability of the restorative procedure using intraradicular posts primarily depend on the remaining amount around the post (ferrule), the type and position of the tooth in the arch (impacting the masticatory forces exerted on the restored tooth), and the correct application of the cementation technique. It is noteworthy that fiberglass posts offer substantial advantages by presenting a modulus of elasticity similar to dental structure, ensuring a more homogeneous distribution of masticatory forces and reducing the risk of fractures. These findings have practical implications for material selection in restorative procedures involving intraradicular posts.(AU)


Objetivo: Esta revisão sistemática visa comparar a longevidade clínica de pinos intrarradiculares metálicos e de fibra de vidro em dentes com coroas severamente comprometidas, através de estudos clínicos randomizados e relatos de casos, publicados nos últimos onze anos. Material e Métodos: A pesquisa foi conduzida nas bases de dados PubMed, Medline, Lilacs e BBO, utilizando a primeira estratégia de busca com os s 'pinos dentais' e 'longevidade' e 'pinos reforçados com fibra de vidro' ou 'pinos metálicos'. A segunda estratégia de busca consistiu na análise das referências dos artigos identificados pela primeira estratégia. Ambos os estudos foram delineados com critérios rigorosos de inclusão e exclusão. Resultados: Não se constataram diferenças estatisticamente significativas e clinicamente relevantes na longevidade entre pinos metálicos e de fibra de vidro. Conclusão: O êxito clínico e a durabilidade do procedimento restaurador empregando pinos intrarradiculares dependem primordialmente da quantidade de remanescente ao redor do pino (férula), do tipo e posição do dente na arcada (o que impacta nas forças mastigatórias exercidas sobre o dente restaurado) e da aplicação correta da técnica de cimentação.Destaca-se que o pino de fibra de vidro oferece vantagens substanciais ao apresentar módulo de elasticidade similar à estrutura dentária, assegurando uma distribuição mais homogênea das forças mastigatórias e reduzindo o risco de fraturas (AU)


Assuntos
Materiais Dentários , Pinos Dentários
6.
J. appl. oral sci ; J. appl. oral sci;32: e20230439, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558238

RESUMO

Abstract Objective To evaluate the effect of the labiolingual diameter and construction of an endodontically treated (ET) anterior tooth with crown restoration on stress distribution and biomechanical safety under occlusal loading. Methodology Three-dimensional finite element models were generated for maxillary central incisors with all-ceramic crown restorations. The labiolingual diameters of the tooth, defined as the horizontal distance between the protrusion of the labial and lingual surfaces, were changed as follows: (D1) 6.85 mm, (D2) 6.35 mm, and (D3) 5.85 mm. The model was constructed as follows: (S0) vital pulp tooth; (S1) ET tooth; (S2) ET tooth with a 2 mm ferrule, restored with a fiber post and composite resin core; (S3) ET tooth without a ferrule, restored with a fiber post and composite resin core. A total of 12 models were developed. In total, two force loads (100 N) were applied to the crown's incisal edge and palatal surface at a 45° oblique angle to the longitudinal axis of the teeth. The Von Mises stress distribution and maximum stress of the models were analyzed. Results Regardless of the loading location, stress concentration and maximum stress (34.07~66.78MPa) in all models occurred in the labial cervical 1/3 of each root. Both labiolingual diameter and construction influenced the maximum stress of the residual tooth tissue, with the impact of the labiolingual diameter being greater. A reduction in labiolingual diameter led to increased maximum stress throughout the tooth. The ferrule reduced the maximum stress of the core of S2 models (7.15~10.69 MPa), which is lower compared with that of S3 models (19.45~43.67 MPa). Conclusion The labiolingual diameter exerts a greater impact on the biomechanical characteristics of ET anterior teeth with crown restoration, surpassing the influence of the construction. The ferrule can reduce the maximum stress of the core and maintain the uniformity of stress distribution.

7.
Braz. dent. j ; Braz. dent. j;35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1564090

RESUMO

Abstract This study aimed to evaluate the bond strength between relined fiberglass posts with different composite resin opacities in different thirds of the intraradicular dentin. Thirty single-rooted premolars were endodontically treated and divided into three groups (n=10): fiberglass posts relined with translucent composite resin, fiberglass posts relined with opaque composite resin, and fiberglass posts without relining. After cementation of the posts, the specimens were cut perpendicular to the long axis of the tooth in slices of approximately 1.3 mm of each third to be analyzed (cervical, middle, and apical) and then subjected to the push-out test. The bond strength (MPa) data were subjected to Shapiro-Wilk normality tests and two-way repeated measures analysis of variance, considering the experimental groups and different regions as study factors. Tukey's post-hoc test (p<.05) was applied for comparisons between the groups. In the cervical third, higher values of bond strength were found for the group relined with translucent resin, with a statistically significant difference for the other groups. In the other regions, both opaque and translucent resins showed similar results, but both showed higher values of bond strength compared to fiberglass posts without relining. The bond strength of fiberglass posts to different thirds of intraradicular dentin is influenced by composite resin relining as well as the opacity of the resin. The use of translucent composite resin is a more effective alternative for fiberglass posts relining.


Resumo Este estudo teve como objetivo avaliar a resistência de união entre pinos de fibra de vidro anatomizados com resinas compostas de diferentes opacidades em diferentes terços da dentina intrarradicular. Trinta pré-molares uniradiculares foram tratados endodonticamente e divididos em três grupos (n=10): pinos de fibra de vidro anatomizados com resina composta translúcida, pinos de fibra de vidro anatomizados com resina composta opaca e pinos de fibra de vidro sem anatomização. Após a cimentação dos pinos, os corpos de prova foram cortados perpendicularmente ao longo eixo do dente em fatias de aproximadamente 1,3 mm de cada terço a ser analisado (cervical, médio e apical) e posteriormente submetidos ao teste de push-out. Os dados de resistência de união (MPa) foram submetidos a testes de normalidade de Shapiro-Wilk e ANOVA dois fatores para análises repetidas, considerando os grupos experimentais e diferentes regiões como fatores de estudo. O teste post-hoc de Tukey (p=0,05) foi aplicado para comparações entre os grupos. No terço cervical foram encontrados maiores valores de resistência de união no grupo com anatomização com resina translúcida, com diferença estatisticamente significativa para os demais grupos. Nas demais regiões, tanto as resinas opacas quanto as translúcidas apresentaram resultados semelhantes, mas ambas apresentaram valores de resistência de união superiores aos pinos de fibra de vidro sem anatomização. A resistência de união dos pinos de fibra de vidro aos diferentes terços da dentina intrarradicular é influenciada pela anatomização da resina composta, bem como pela opacidade da resina. A utilização de resina composta translúcida é uma alternativa mais eficaz para a anatomização de pinos de fibra de vidro.

8.
Aust Dent J ; 2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37888911

RESUMO

BACKGROUND: Medium-term evaluate the bond strength and tag formation in root dentin using self-adhesive cements Maxcem Elite (MCE), Relyx U200 (RU2), SeT PP (SPP) and Megalink (MGL) compared to conventional cement Relyx ARC (ARC) for glass fibre post cementation. MATERIALS AND METHODS: One hundred bovine incisors roots were endodontically treated and divided into 5 groups (n = 20) according to the cementation system: MCE, RU2, SPP, MGL and ARC. All cementation systems were evaluated at 24 h (1) and 12 months (2) after post cementation. Specimens from the cervical, middle and apical thirds of the root were submitted to push-out bond strength test and confocal laser microscopy to verify the dentin penetration. The adhesive failure mode was classified as adhesive, cohesive and mixed. Data were analysed by one-way ANOVA and Tukey tests (α = 5%). RESULTS: ARC-1 and ARC-12 showed the highest bond strength (P < 0.05). ARC showed the greatest tag extension, regardless of the third (P < 0.05). The most frequent failure mode in the 24-h analysis was cohesive, regardless of the cement used. For the 12-month analysis, mixed failure was the most frequent. CONCLUSION: Conventional cement (ARC) showed the highest bond strength and tag extension, regardless of the evaluation period. In all cementation systems, the bond strength decreased after 12 months. © 2023 Australian Dental Association.

9.
J Esthet Restor Dent ; 35(4): 677-686, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36602235

RESUMO

OBJETIVE: This study evaluated the influence of alveolar bone height and post type on compressive force resistance, fracture pattern, and stress distribution in endodontically treated teeth. MATERIALS AND METHODS: Bovine roots were endodontically treated and divided into eight groups (n = 10) according to alveolar bone height (normal alveolar bone and alveolar bone loss - 2 and 5 mm from the margin of the crown, respectively) and post type (prefabricated glass fiber post, anatomic glass fiber post, customized milled glass fiber post-and-core and customized milled polyetheretherketone (PEEK) post-and-core). Mechanical fatigue was simulated (300.000 cycles/50 N/1.2 Hz). Compression force resistance (N) was analyzed by two-way ANOVA and Tukey test (α = 0.05). Fracture patterns were described as percentages. Stress distribution was analyzed by finite element analysis. RESULTS: Significant diferences were found for alveolar bone height (P < 0.0001): normal alveolar bone groups showed higher mean values of compression force resistance compared to alveolar bone loss groups, while no significant differences were found for post type (P = 0.4551), and there was no double interaction between them (P = 0.5837). Reparable fractures were more predominant in normal alveolar bone groups, especially in the milled glass fiber and PEEK post-and-core groups. Stress distribution was similar in groups with prefabricated glass fiber posts and milled PEEK posts-and-cores, and the alveolar bone loss condition significantly increased stress concentration and strain values, mainly on apical dentin. CONCLUSIONS: Alveolar bone loss due to physiological aging and/or periodontal disease may lead to increased risk of restored tooth failure, although milled glass fiber and PEEK posts-and-cores provide more reparable fractures. CLINICAL SIGNIFICANCE: Custom-made glass fiber and PEEK post-and-cores are interesting options, since they enable clinicians to work with a single-body post-and-core system that avoid several materials interfaces and fits well in the root canal provided promising results to improve the failure behavior of restored roots, as they offer more reparable fractures even in situations of alveolar bone loss.


Assuntos
Perda do Osso Alveolar , Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Animais , Bovinos , Materiais Dentários , Fraturas dos Dentes/prevenção & controle
10.
J Prosthodont ; 32(9): 807-814, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36482016

RESUMO

PURPOSE: To evaluate the influence of post type and mechanical aging on compression force resistance, fracture pattern, and stress distribution in weakened roots. MATERIALS AND METHODS: Bovine roots were endodontically treated and widened-and randomly divided into 8 groups (n = 10) according to post type (prefabricated glass fiber post and customized anatomic glass fiber post, milled glass fiber post-and-core, and milled polyetheretherketone post-and-core) and mechanical aging (without and with mechanical aging). Three hundred thousand cycles of mechanical fatigue were performed and compression force resistance (N) was analyzed by two-way ANOVA and Tukey test (α = 0.05). Fracture patterns were reported and stress distribution was analyzed by finite elements analysis. RESULTS: There was a significant effect of post type (p = 0.032) and mechanical aging (p = 0.009), but no double interaction (p = 0.879). Higher values were recorded in the milled glass fiber and polyetheretherketone post-and-core groups compared to the prefabricated glass fiber post groups, and no significant difference was found among anatomic glass fiber post groups and other groups. Reparable fractures were predominant in the milled glass fiber and polyetheretherketone post-and-core groups. Prefabricated glass fiber posts and milled polyetheretherketone post-and-cores showed similar stress distribution. CONCLUSIONS: Post type and mechanical aging influence the compression force resistance and fracture pattern of weakened roots. Milled glass fiber and polyetheretherketone post-and-cores exhibited higher compression force resistance and more reparable fractures compared to prefabricated glass fiber posts. Prefabricated glass fiber posts and milled polyetheretherketone post-and-cores showed similar stress distribution.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Animais , Bovinos , Resinas Compostas , Materiais Dentários , Análise do Estresse Dentário , Vidro , Teste de Materiais , Dente não Vital/terapia
11.
Braz. oral res. (Online) ; 37: e42, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1430032

RESUMO

Abstract The purpose of this study was to evaluate the effect of dentin moisture (moist and dry) on the bonding of fiber posts to root dentin with different adhesive strategies (etch-and-rinse, self-etch, and self-adhesive). Seventy-two extracted single-rooted human teeth were endodontically treated and divided into six groups (n = 12) according to the moisture of dentin surface and adhesive systems as follows: a) etch-and-rinse/moist, b) etch-and-rinse/dry, c) self-etch/moist, d) self-etch/dry, e) self-adhesive/moist, and 6) self-adhesive/dry. The specimens were sectioned into six slices for push-out bond strength (BS), nanoleakage (NL) by SEM, and Vickers microhardness (VHN) of the resin cement. A universal testing machine (AG-I, Shimadzu Autograph) was used at a crosshead speed of 0.5 mm/min until post extrusion, with a load cell of 50 kg for evaluation of the push-out strength. Data on BS, NL, and VHN were evaluated by two-way ANOVA and Tukey's test (α = 0.05). Dentin moisture as the main factor was not significantly different for the push-out test. However, higher BS values can be observed for the etch-and-rinse group. A lower percentage of NL was found in the dry dentin groups. The moisture pattern was not significant in the hardness values for the pre-etching groups. Additional moisture did not increase the evaluated properties.

12.
J. appl. oral sci ; J. appl. oral sci;31: e20230241, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1521079

RESUMO

Abstract Objective The use of a fiber glass post (FGP) type and choice of FGP diameter to restore endodontically treated incisors without ferrule is controversial. This study evaluated survival rate and failure mode of severely compromised central incisors without ferrule rehabilitated using resin-based composite (RBC) with or without FGP with different diameters. Methodology A total of 60 decoronated bovine incisors without a ferrule were endodontically treated and prepared for 1.4, 1.6, and 1.8 mm diameter FGPs (Whitepost System DC 0.5, Fit 0.4, and DCE 0.5; FGM). Half of the teeth received FGPs cemented using dual-cure resin cement (Allcem Core; FGM), the other half were filled using only bulk-fill RBC (OPUS Bulk Fill; FGM). The crowns were directly restored with RBC. The roots were embedded in polystyrene resin and the periodontal ligament was simulated with polyether impression material. Fatigue testing was conducted under 5 Hz cyclic loading at 30 degrees to the incisal edge, beginning at 50 N (5,000 cycles) as a warmup. After, the load was increased 100 N every 15,000 cycles until fracture occurred. All specimens were subjected to transillumination, micro-CT analysis, and digital radiography before and after fatigue testing. Fracture mode was classified according to severity and repair potential. Data were analyzed with Kaplan-Meier survival test and post hoc log-rank test (α=0.05) for pairwise comparisons. Results Using FGP significantly increased the number of cycles to failure, irrespective of FGP diameters (p=0.001). The FGP diameters had no statistically significant effect on cycles to failure or failure mode. Conclusion Using FGP without ferrule improved survival rate of structurally severely compromised central incisors compared with rehabilitation without FGP. The diameter of the FGPs had no effect on the survival rate and failure mode.

13.
J Mech Behav Biomed Mater ; 135: 105486, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36182677

RESUMO

Chemical composition of temporary cements interferes in the bond strength and quality of the bond interface of glass fiber posts to root dentin. The aim of the present study was to evaluate the influence of different temporary cements on the bond strength of fiberglass posts and resin cement. Thirty-two maxillary central incisor roots were standardized at 15 mm length. The root canals were prepared with Reciproc R50 and filled with a R50 single cone and AH Plus. Ten mm of filling material was removed with a heated Schilder condenser, leaving 5 mm of apical filling material. The roots were randomly distributed into 4 groups (n = 8). In the control group, the root canal was prepared with a standard drill according to the post diameter (DC #1, FGM, Joinville, Brazil), irrigated with 5 mL of distilled water and immediately received the fiberglass post cemented with self-adhesive resin cement. For the other groups, cores were made with temporary intraradicular retainers cemented with different temporary cements: methacrylate-based resin (Bifix Temp - Voco), calcium hydroxide-based (Provicol - Voco) and zinc oxide-based - eugenol-free (Relyx Temp NE - 3M). After 7 days, mechanical removal of the temporary retainers, preparation, irrigation of the root canal and cementation of the fiberglass post were performed, following the same protocol that had been performed in the control group. The roots were sectioned to obtain 3 slices per root third. The most cervical section of each third was used for the push-out test and failure pattern analysis, while the most apical section was subjected to analysis of the adhesive interface by scanning electron microscopy (SEM). The BS data were compared between groups using the two-way ANOVA and Tukey post-test. The failure pattern results were expressed in percentage and compared between groups using the chi-square test and the material adaptation data at the bond interface were evaluated using the Kruskal-Wallis and Dwass-Steel-Critchlow-Fligner tests. The results showed higher BS in the cervical third, with a higher value in the control group (10.8 ± 0.94) and Bifix Temp group (9.78 ± 0.71), with no statistically significant difference between these groups (P > .05). The middle and apical thirds showed no statistically significant difference (P > .05). As regards the type of failure, a higher percentage of mixed adhesive failures was observed for all groups. Analysis of the adhesive interface by SEM showed that the temporary cement Bifix Temp showed greater adaptation at the bond interface. It was concluded that the methacrylate-based resin temporary cement showed the highest bond strength values and best adaptation to root dentin than the zinc oxide-based and calcium hydroxide-based temporary cements.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Óxido de Zinco , Hidróxido de Cálcio , Cimentação/métodos , Análise do Estresse Dentário , Dentina , Vidro/química , Hidroxibenzoatos , Teste de Materiais , Metacrilatos , Nitrofuranos , Cimentos de Resina/química , Aço , Água
14.
Rev. estomatol. Hered ; 32(4): 371-380, oct.-dic. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1559988

RESUMO

RESUMEN Objetivo: Evaluar las propiedades de flexión y topografía de los postes de fibra tratados superficialmente. Material y Métodos : Experimental, In vitro. Las muestras fueron divididas en dos grupos, se evaluó la flexibilidad de 40 postes de fibra de vidrio de 2 casas comerciales para cada procedimiento de acondicionamiento P1: FGM White Post DC; P2: MAQUIRA Fiber Post. Las técnicas de acondicionamiento fueron: T1: control T2: Ácido Fluorhídrico 10% 15 segundos T3: Peróxido de Hidrógeno 24% 60 segundos T4: oxido de aluminio 50 µm y se sometieron a la máquina universal de ensayos, para la prueba de flexión de 3 puntos. Se observó la superficie topográfica de los postes de fibra de vidrio utilizando un microscopio electrónico de barrido. Resultados : La deflexión (mm) se evidenció diferencia significativa comparando los grupos control y los grupos acondicionados con un valor máximo promedio de 0,59mm ±0,04 y un valor mínimo de 0,51mm ±0,06. En la fuerza máxima (N) se evidenció diferencia significativa comparando los grupos control y los grupos acondicionados, con un valor máximo de 133,68 ±11,42 N y un valor mínimo de 103,48 ±17,79 N. Conclusiones : No se encontró efectos adversos sobre las propiedades de flexión para ambos grupos de postes de fibra de vidrio después del acondicionamiento de superficie con los diferentes protocolos.


ABSTRACT Objectives: To evaluate the bending and topography properties of surface treated fiber posts. Material and Methods : Experimental, In vitro. The samples were divided into two groups, the flexibility of 40 fiberglass posts from 2 commercial houses was evaluated for each conditioning procedure P1: FGM White Post DC; P2: MAQUIRA Fiber Post. The conditioning techniques were: T1: control T2: Hydrofluoric Acid 10% 15 seconds T3: Hydrogen Peroxide 24% 60 seconds T4: aluminum oxide 50 µm and were subjected to the universal testing machine, for the bending test of 3 points. The topographic surface of the fiberglass posts was observed using a scanning electron microscope. Results : The deflection (mm) showed a significant difference comparing the control groups and the conditioned groups with an average maximum value of 0.59mm ±0.04 and a minimum value of 0.51mm ±0.06. In the maximum force (N), a significant difference was observed when comparing the control groups and the conditioned groups, with a maximum value of 133.68 ±11.42 N and a minimum value of 103.48 ±17.79 N. Conclusions : No adverse effects on bending properties were found for both groups of fiberglass posts after surface conditioning with the different protocols.

15.
J Contemp Dent Pract ; 23(4): 388-392, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35945830

RESUMO

AIM: To assess dentin-post bond strength and mode of failure through tensile strength testing of two endodontic post systems: CAD/CAM custom-milled fiber posts vs Splendor SAP. MATERIALS AND METHODS: Thirty extracted single-rooted mandibular premolars were sectioned 2 mm coronal to the cementoenamel junction. Root length was standardized at 15 mm, and the root canals were instrumented with #20 K-files followed by 30/0.03 and 30/0.05 ProDesign Logic rotary files, under irrigation with 2.5% NaOCl, and then submitted to final irrigation with 17% EDTA. Canals were filled with gutta-percha and AH PLUS sealer. After 24 hours, the teeth were prepared for post placement to a depth of 10 mm and randomly allocated into two experimental groups (n = 15): CAD/CAM (CC) and Splendor SAP (SS). All posts were cemented with RelyX U200 dual-cure self-adhesive resin cement. The roots were embedded in acrylic resin, and the specimens were stored for 7 days in moist heat (37°C). Tensile strength testing until failure was then performed in a universal testing machine using a crosshead speed of 0.5 mm/minute. The final failure load was tabulated for statistical analysis, and the G test was used to compare the failure modes observed under light microscopy (5× magnification). RESULTS: There was no significant difference between groups regarding tensile bond strength to root dentin (p = 0.325). Conversely, failure mode differed significantly between groups (p = 0.037). CONCLUSION: The tensile bond strength observed for the CAD/CAM and Splendor SAP post systems was similar. Adhesive failure was predominant in both groups; however, the CAD/CAM custom-milled fiber posts failed predominantly at the dentin-resin cement interface, whereas Splendor SAP posts failed mostly at the post-resin cement interface. CLINICAL SIGNIFICANCE: A strong post-dentin bond is a key to the success of dental restorations and prosthetic rehabilitation. In teeth with severe coronal decay and wide canals, both of the tested systems would be able to achieve good cervical fit.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Desenho Assistido por Computador , Cavidade Pulpar , Análise do Estresse Dentário , Dentina , Teste de Materiais , Cimentos de Resina/química
16.
Eur J Oral Sci ; 130(4): e12881, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35673777

RESUMO

Systematic review and network meta-analyses were performed to answer the question: Do intraradicular chemical pretreatments affect the bond strength of the adhesive interface between dentine and fiber post cements? A literature search was performed in PubMed, Scopus, Web of Science, LILACS, BBO, and Cochrane Library in October 2018 (updated September 2021). In vitro studies that compared the bond strength assessed by push-out tests following at least two dentine chemical treatments prior to fiber post cementation were included. Risk of bias was evaluated. A random-effects Bayesian-mixed treatment comparison model was used to compare push-out bond strength of different chemical pretreatments. SUCRA (surface area under the cumulative ranking) analysis was performed to rank the pretreatments. After removing duplicates and screening titles and abstracts, 61 studies remained. SUCRA analysis showed that the best bond strength values for self-etch, etch-and-rinse, and self-adhesive cements were ethyl acetate (SUCRA: 99.8%), low concentration NaOCl (SUCRA: 83.4%), and grape seed extract (SUCRA: 97.6%), respectively. According to the SUCRA rankings, ethanol was in a good position for all adhesive strategies (SUCRA: 78.6%). The use of chemical pretreatments in intraradicular dentine of endodontically treated teeth depends on the adhesive and cementation strategy. The pretreatment generally associated with the highest bond strength was ethanol.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Teorema de Bayes , Cimentos Dentários/farmacologia , Dentina , Etanol/química , Etanol/farmacologia , Teste de Materiais , Metanálise em Rede , Cimentos de Resina/química
17.
Clin Oral Investig ; 26(1): 781-787, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34231058

RESUMO

OBJECTIVES: This prospective study assessed the effect of post type used to restore endodontically treated teeth in the onset, progression, and remission of periapical lesions. MATERIALS AND METHODS: One hundred and forty teeth (92 patients) were endodontically treated and received a glass fiber post or a cast metal post and a final restoration at a University Clinic by undergraduate students. All patients were followed up for a mean period of 5.1 ± 2.2 years. Periapical Index (PAI) was used for endodontic assessment. Two calibrated and blind examiners assessed the radiographs. The longevity of the endodontic treatment was analyzed using Kaplan-Meier statistics. RESULTS: Of the included teeth, 67.1% received glass fiber posts while 32.9% received cast metal posts. There were 4 endodontic failures, two glass fiber posts with a PAI = 3 in the baseline and PAI = 4 in the last follow-up, and one PAI = 4 in baseline and last follow-up. One cast metal post-failure was PAI = 4 in the baseline and the last follow-up. After 9.4 years, the overall success rate of the endodontic treatment was 97.1% (p = 0.7). CONCLUSIONS: The tested posts presented similar endodontic healing. Precautions taken during endodontic therapy, post cementation, and final restoration are more likely to be responsible for the success of endodontic treatment rather than a specific type of post. Clinical relevance The type of post is not related to the success of the endodontic treatment.


Assuntos
Técnica para Retentor Intrarradicular , Dente não Vital , Brasil , Cimentação , Vidro , Humanos , Estudos Prospectivos , Dente não Vital/terapia
18.
Braz. dent. sci ; 25(4): 1-14, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1395942

RESUMO

The current review aimed to compare the mechanical properties and clinical behavior of fiberglass and cast metal posts. It included in-vitro studies, finite element analysis, clinical studies, and systematic reviews that evaluated fiberglass and metal posts with reliable methodologies. The reports in the literature diverge on tooth failure modes and stress distributions in the root according to different posts. Investigations suggest that fiberglass posts are preferable because their elastic modulus is similar to dentin. Other studies mention that the flexibility of fiber posts may damage the interface. The fracture load values of different studies could not be compared. The presence of a ferrule seems beneficial. Cast metal posts provide higher characteristic strength to the set but with more unfavorable failures. Intraradicular posts with a lower elastic modulus produce more stress between the cement layer and dentin. In conclusion, fiberglass and cast metal posts can be used with a ferrule. Cast metal posts seem more appropriate for weakened teeth. The presence of a ferrule benefits the system. Weakened teeth tolerate higher loads when restored with cast metal posts, but when these posts fail, the only solution is tooth extraction. Clinical follow-ups cannot yet detect differences between the survival rates of intraradicular fiberglass and cast metal posts (AU)


O objetivo da presente revisão foi comparar as propriedades mecânicas e o comportamento clínico de pinos de fibra de vidro e núcleos metálicos fundidos. Estudos laboratoriais, analise por elementos finitos, estudos clínicos e revisões sistemáticas que avaliaram pinos de fibra de vidro e metálicos, com metodologia confiável foram selecionados. A literatura mostra-se bastante controversa sobre os modos de falha do dente e a distribuição de tensões na raiz de acordo com diferentes tipos de pinos. Algumas investigações sugerem que pinos de fibra de vidro são preferíveis porque seu módulo de elasticidade é semelhante ao da dentina, enquanto outras mencionam que a flexibilidade do pino de fibra pode ser prejudicial à interface adesiva. Os valores de carga de fratura em diferentes estudos não podem ser comparados. A presença de férula é benéfica. O núcleo metálico fundido resulta em maior resistência característica do conjunto, mas falhas mais desfavoráveis. Também, pinos com menor módulo geram mais tensão entre a camada de cimento e a dentina. Em conclusão, verificou-se que tanto pino de fibra de vidro como núcleo metálico fundido podem ser utilizados quando a férula está presente. Os núcleos metálicos fundidos parecem ser mais indicados para dentes fragilizados. É evidente que a presença de férula é benéfica para o sistema. Dentes fragilizados toleram cargas maiores quando restaurados com núcleos metálicos fundidos; porém, quando falham, a única solução é a extração do dente. Os acompanhamentos clínicos ainda não são capazes de detectar diferença entre as taxas de sobrevivência dos pinos de fibra de vidro e núcleos metálicos (AU)


Assuntos
Prostodontia , Prótese Dentária , Análise de Elementos Finitos , Pinos Dentários
19.
São José dos Campos; s.n; 2022. 111 p. tab, ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1410402

RESUMO

O presente estudo teve por objetivo avaliar a resistência à flexão de um pino experimental de fibra de vidro vazado, e a resistência adesiva entre este pino experimental à dentina radicular, associando a utilização de um dispositivo iluminador em fibra óptica, sob o processo de envelhecimento, além de determinar a distribuição de tensão pela Análise de Elementos Finitos (FEA). O pino experimental e o dispositivo iluminador de fibra óptica têm por finalidade aumentar a efetividade de fotoativação dos cimentos resinosos nos terços médios e apicais dos canais radiculares. Para o teste de flexão de 3 pontos, estritamente do pino de fibra de vidro, as amostras foram divididas em 4 grupos (n=10): pino convencional (pc), pino experimental sem preenchimento (pp), com preenchimento de cimento resinoso (ppc) e com preenchimento de fibra óptica (ppf). Para o teste de resistência adesiva Pull-out, 100 raízes de dentes bovinos foram restauradas com retentores intrarradiculares e coroas de resina composta, distribuídos em 10 grupos (n=10), tendo como variáveis: o tipo de pino de fibra de vidro [convencional (C) ou perfurado (P)], o sistema de fotoativação [com ou sem o iluminador de fibra óptica (O)], o tipo de cimento resinoso [fotoativado (F) ou polimerização dual (D)] e o envelhecimento das amostras [com e sem ciclagem mecânica (C)]. O processo de envelhecimento foi realizado através da ciclagem mecânica e as amostras foram submetidas ao teste de resistência adesiva Pull-out. A análise do modo de falha foi realizada em Estereomicroscópio. A Análise em Elementos Finitos avaliou a distribuição de tensão pela análise de von Mises, deformação total e tensão máxima principal no Software Ansys 19.3. A análise estatística foi constituída pelo teste de normalidade Shapiro-Wilk, análise de variância (ANOVA) 1, 2 e 3 fatores e teste Tukey 5%. As médias e desvios padrão de resistência à flexão foram (MPa): pc = 677 ± 81,1; ppc = 419 ± 23,2; ppf = 200 ± 32,5 e pp = 177 ± 32,8. As médias e desvios padrão de resistência adesiva foram (MPa): CD = 12,2 ± 1,21; PD = 11,1 ± 1,32; PF = 10,9 ± 1,29; POD = 13,7 ± 1,16; POF = 11,9 ± 1,48; CDC = 10,1 ± 1,33; PDC = 9,25 ± 1,11; PFC = 8,37 ± 1,25; PODC = 10,8 ± 0,95 e POFC = 9,82 ± 1,02. Os resultados do modo de falha foram: adesiva entre pino e cimento (56%), mista predominantemente adesiva entre cimento e dentina (22%), adesiva entre cimento e dentina (14%) e a mista predominantemente adesiva entre pino e cimento (8%). Concluiu-se que entre os pinos experimentais, o grupo do pino perfurado preenchido com cimento resinoso obteve o maior valor de resistência à flexão, a utilização do dispositivo iluminador aumentou os resultados de resistência adesiva nos grupos dos pinos perfurados e não houve diferença na distribuição de tensões entre os grupos. (AU)


The present study aimed to evaluate the flexural strength of an experimental hollow glass fiber post, and the bond strength between this experimental post and root dentin, associating the use of an optical fiber illuminating device, under the aging process, in addition to determine the stress distribution by Finite Element Analysis (FEA). The experimental post and optical fiber illuminating device are intended to increase the polymerization effectiveness of resin cements in the middle and apical regions of root canals. For the 3-point bending test, strictly of the fiber post, the samples were divided into 4 groups (n=10): conventional post (pc), experimental post without filling (pp), with resin cement filling (ppc) and with optical fiber filling (ppf). For the Pull-out test, 100 roots of bovine teeth were restored with intraradicular retainers and composite resin crowns, distributed into 10 groups (n=10), with the following variables: glass fiber post type [conventional (C) or hollow (P)], the photocuring system [with or without the optical fiber illuminating device (O)], the type of resin cement [light cured (F) or dual cured (D)] and aging of the samples [with and without mechanical cycling (C)]. The aging process was performed by mechanical cycling and the samples were submitted to the Pull-out bond strength test. Failure mode analysis was performed using a stereomicroscope. Finite Element Analysis evaluated the stress distribution by von Mises analysis, total strain and maximum principal stress in Ansys Software 19.3. Statistical analysis consisted of the Shapiro-Wilk normality test, 1-, 2- and 3-way analysis of variance (ANOVA) and Tukey test 5%. The means and standard deviations of flexural strength were (MPa): pc = 677 ± 81.1; ppc = 419 ± 23.2; ppf = 200 ± 32.5 and pp = 177 ± 32.8. The means and standard deviations of bond strength were (MPa): CD = 12.2 ± 1.21; PD = 11.1 ± 1.32; PF = 10.9 ± 1.29; POD = 13.7 ± 1.16; POF = 11.9 ± 1.48; CDC = 10.1 ± 1.33; PDC = 9.25 ± 1.11; PFC = 8.37 ± 1.25; PODC = 10.8 ± 0.95 and POFC = 9.82 ± 1.02. The failure mode results were: adhesive between post and cement (56%), mixed predominantly adhesive between cement and dentin (22%), adhesive between cement and dentin (14%) and mixed predominantly adhesive between post and cement (8 %). It was concluded that among the experimental posts, the hollow post group filled with resin cement obtained the highest flexural strength value, the use of the illuminating device increased the results of bond strength in the hollow post groups and there was no difference in the stress distribution among the groups (AU)


Assuntos
Teste de Materiais , Técnica para Retentor Intrarradicular , Cimentos de Resina , Análise de Elementos Finitos , Lâmpadas de Polimerização Dentária
20.
Saudi Dent J ; 33(8): 917-922, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34916764

RESUMO

PURPOSE: To evaluate the push-out bond strength (PBS) and failure mode of single adjustable (SAP) and customized (CP) posts cemented to root canal dentin using conventional (RelyX Ultimate) or self-adhesive (RelyX U200) dual-cure resin cements. METHODS: Herein, 40 bovine mandibular incisors were divided into four groups (n = 10): SAP cemented with RelyX Ultimate (SAP-UT), SAP cemented with RelyX U200 (SAP-U2), CP cemented with RelyX Ultimate (CP-UT), and CP cemented with RelyX U200 (CP-U2). PBS and failure modes were analyzed. Three-way repeated measures ANOVA test followed by Tukey's test and Fisher-Freeman-Halton exact test were used for data analysis (α = 5%). RESULTS: The PBS values for SAP (p < .05) were higher than those for CP and were not influenced by the root third and resin cement (p > .05). When conventional resin cement was used, the SAP showed significant differences compared to CP (p < .05). When cemented with RelyX Ultimate, a higher prevalence of mixed and adhesive failures for SAP and CP, respectively, was observed (p < .05). For the self-adhesive resin cement, the failures were mostly adhesive (p < .05). CONCLUSION: SAP showed better performance than CP. The root third and resin cements did not influence the PBS. The most prevalent failures were adhesive and mixed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA