Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz. dent. j ; Braz. dent. j;32(1): 91-97, Jan.-Feb. 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1180719

RESUMO

Abstract This study investigated the effects of oxygen inhibition and finishing/polishing procedures on the composite resin properties. One bulk-fill and two conventional composite resins (nanoparticle and microhybrid) were evaluated. Specimens were prepared using 4 surface treatments: control, no treatment; Gly, oxygen inhibition with glycerin; FP, finishing and polishing; Gly + FP, glycerin followed by finishing and polishing. The degree of conversion (DC) was measured using Fourier Transformed Infrared Spectroscopy (FTIR) immediately and after 15 days (n=5). Color stability (ΔEab, and ΔE00) and opacity were evaluated using a spectrophotometer after 15 days of immersion in coffee, using the CIELAB system (n=5). Data were analyzed by two-way ANOVA and Tukey tests (α=0.05) and opacity by two-way repeated-measures ANOVA. Glycerin usage increased significantly the DC however had no influence on the ΔEab, ΔE00 and, opacity values. Finishing and polishing reduced ΔEab and ΔE00 values, regardless of composite resins. Microhybrid showed higher opacity, followed by the nanoparticle and bulk fill, regardless of surface treatment. Post-polymerization polishing procedures resulted in lower conversion than using an oxygen inhibitor agent (Gly condition), but similar staining caused by coffee.


Resumo Este estudo investigou os efeitos da inibição de oxigênio e dos procedimentos de acabamento/polimento nas propriedades das resinas compostas. Foram avaliadas uma resina composta bulk fill e duas resinas convencionais (nanoparticulada e microhíbrida). Os espécimes foram confeccionados, variando o tratamento de superfície: controle, sem tratamento; glicerina (inibidor de oxigênio); acabamento e polimento; glicerina + acabamento e polimento. O grau de conversão (GC) foi medido pela Espectroscopia de Infravermelho Transformada de Fourier (FTIR) imediatamente e após 15 dias da confecção dos espécimes (n=5). Os índices de alteração de cor ΔEab, ΔE00 e opacidade foram avaliados por meio de espectrofotômetro, após 15 dias de imersão no café, utilizando o sistema CIELAB (n=5). Os dados da alteração da cor foram analisados pelos testes ANOVA de dois fatores e Tukey (α=0,05) e a opacidade por ANOVA de medidas repetidas. O uso de glicerina aumentou significativamente o GC, no entanto, não teve influência sobre os valores ΔEab e ΔE00. O acabamento e o polimento reduziram os valores de ΔEab e ΔE00, independentemente da resina composta. A resina microhíbrida apresentou maior opacidade, seguida pela nanoparticula e bulk-fill, independentemente do tratamento de superfície. O acabamento e polimento resultou em menor grau de conversão das resinas compostas se comparado ao uso de um agente inibidor de oxigênio (glicerina), porém apresenta resultados similares para a pigmentação pelo café.


Assuntos
Oxigênio , Resinas Compostas , Propriedades de Superfície , Teste de Materiais , Cor , Materiais Dentários , Polimento Dentário
2.
Appl Radiat Isot ; 150: 43-52, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31121487

RESUMO

Currently, advanced dosimeters like polymer gels are capable of obtaining reliable and accurate 3D dose distributions from correlations with the different polymerization degrees induced by incident radiation. Samples of polymer gel dosimeters are commonly read out using magnetic resonance imaging or optical methods like visible light transmission or laser computed tomography. Alternatively, this work proposes and evaluates the implementation of Raman spectroscopy to provide direct information on the effect of oxygen permeating through the walls of phantoms on the polymerization initiated by irradiation in three types of polymer gel dosimeters, namely NIPAM, ITABIS and PAGAT. The aim of the present study is to provide better and complete interpretations using three different containers, adequate for integral, 2D and 3D dose mapping. Moreover, Raman spectroscopy has been used to analyze the well-known effect of oxygen inhibition on the different polymer gel dosimeters remarking the importance of avoiding air exposition during sample storage and readout. Dose-response curves for different polymer gels were obtained in terms of measurements with a calibrated ionization chamber. Additionally, dedicated Monte Carlo simulations were performed aimed at characterizing dose for different X-ray irradiation setups, providing also suitable information to evaluate oxygen diffusion through the sample wall. The obtained results were contrasted with optical transmission readout as well as Monte Carlo simulations attaining very good agreements for all dosimeter types.

3.
Eur J Dent ; 8(3): 366-372, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25202218

RESUMO

OBJECTIVES: The objective of the following study is to evaluate the interaction between the resin materials used in immediate dentin sealing (IDS) techniques and impression materials with two different techniques to eliminate the oxygen-inhibition layer. MATERIALS AND METHODS: The occlusal dentin surface of 35 human molars was exposed. The teeth were used in two Groups: Group 1 - Impression with Express XT; Group 2 - Impression with Impregum. Groups 1 and 2 were divided into 14 subgroups: Groups 1a and 2a - Control groups; 1b and 2b - IDS with Clearfil SE Bond (CSE); 1c and 2c - IDS with CSE + additional polymerization with glycerin jelly; 1d and 2d - IDS with CSE + alcohol; 1e and 2e - IDS with CSE and Protect Liner F (PLF); 1f and 2f - IDS with CSE and PLF + additional polymerization with glycerin jelly; and 1g and 2g - IDS with CSE and PLF + alcohol. Five teeth were used in each experimental group, and the tooth surface was photographed using a digital camera. RESULTS: Small quantity of unpolymerized impression material remained attached to the CSE or to the PLF in Groups 1b and 1e. Groups 1c and 1d prevented the interaction. Small quantity of polymerized impression material remained attached to the CSE or to the PLF for Groups 2b and 2e. The same interaction was observed for Groups 2c and 2d. For Groups 2c and 2f, no interactions were observed. CONCLUSION: Resin materials interacted with impression materials. The application of glycerin jelly and alcohol prevented the interaction of CSE with Express XT and PLF with Impregum; however, these treatments were not completely effective in preventing the interaction of CSE with Impregum and PLF with Express XT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA