Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Orofac Orthop ; 85(Suppl 2): 155-164, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38180483

RESUMO

OBJECTIVE: The aim of this study is to assess the microbial contamination of three different brands of esthetic elastomeric ligatures. MATERIALS AND METHODS: Different brands of esthetic ligatures (Unistick Pearl [American Orthodontics, Sheboygan, WI, USA], Power Sticks Pearl [Ortho Technology, Tampa, FL, USA], and Ease [Obscure, 3M Unitek, Monrovia, CA, USA]) were randomly assigned to permanent canines of 25 patients (aged 11-18 years) undergoing corrective orthodontic treatment. After 30 days, the ligatures were removed, processed, and the biofilm composition was analyzed by checkerboard DNA-DNA hybridization for 40 bacterial species. The microbiological data were analyzed using a nonparametric mixed model. RESULTS: The ligatures presented intense microbial contamination after 30 days, but no statistically significant differences were observed among the three groups (p > 0.05). The levels of the evaluated individual species and proportions of the microbial complexes showed no statistically significant differences among the ligature groups (p > 0.05). CONCLUSIONS: Esthetic elastomeric ligatures became multicolonized by several bacterial species after 30 days of exposure to the oral cavity. However, no relevant differences were observed among the biofilm composition formed on the different ligature brands.


Assuntos
Elastômeros , Humanos , Criança , Adolescente , Feminino , Masculino , Hibridização de Ácido Nucleico , Contaminação de Equipamentos , Aparelhos Ortodônticos/microbiologia
2.
Ortho Sci., Orthod. sci. pract ; 17(65): 74-83, 2024. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-1556301

RESUMO

A cada ano que passa a procura por tratamentos ortodônticos está mais frequente, e isso se dá pelo fato da valorização do sorriso e da estética facial estar cada vez mais perceptível perante a sociedade. As modalidades de tratamento são diversas, e com o avanço da tecnologia, estão cada vez mais modernas, confortáveis e objetivas para suprir a necessidade do paciente. Dentre elas, podemos citar a aparatologia ortodôntica fixa que é o sistema mais antigo e os alinhadores estéticos que são os aparelhos mais modernos na ortodontia digital. Esse estudo tem como objetivo relatar dois casos clínicos e revisar a literatura científica existente acerca do tratamento ortodôntico utilizando aparelhos fixos comparados aos alinhadores removíveis, evidenciando suas vantagens e desvantagens, indicações e limitações (AU)


With each passing year the search for orthodontic treatments is more frequent, and this is due to the fact that the appreciation of smile and facial aesthetics is increasingly noticeable before society. The treatment modalities are diverse, and with the advancement of technology, are increasingly modern, comfortable, and objective in view of the needs of the patient. Among them, we can mention the fixed orthodontic aparatology, which is the oldest system, and the aesthetic aligners that are the most modern devices in the face of digital orthodontics. This study aims to report clinical cases and review the existing scientific literature on orthodontic treatment using fixed devices compared to removable aligners, evidencing its advantages and disadvantages indications, and limitations.(AU)


Assuntos
Humanos , Adulto , Aparelhos Ortodônticos Removíveis , Ortodontia , Aparelhos Ortodônticos Fixos
3.
Dental press j. orthod. (Impr.) ; 29(3): e2423159, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1564448

RESUMO

ABSTRACT Introduction: Extraction vs. non-extraction is a crucial decision in orthodontic therapy. Objective: The aim of the present study was to investigate the changes in the dental arch width and buccal corridor after orthodontic treatment using extraction and non-extraction therapy with Damon self-ligating system. Material and Methods: This retrospective study consisted of 35 patients (20 female and 15 male patients with median age of 12.5 years), treated by extracting 4 or 2 premolars, and 37 patients (16 female and 21 male patients with the median age of 12.8 years), treated without premolar extraction. Both groups were treated with Damon self-ligating system. Plaster models before (T0) and after (T1) treatment were measured, and the arch width values were determined at the level of the first molars, second premolars, canines and palatal rugae. Buccal corridor width was measured using the extraoral images at T0 and T1. Paired t-test was used for the analysis of the normally distributed data, and Wilcoxon Mann-Whitney U test was used for the data with non-normal distribution. Values of p<0.05 were set as statistically significant. Results: The upper intercanine width increased significantly in both groups (p<0.01). In the non-extraction group, the arch width increased significantly in the maxillary second premolar and first molar region (p<0.01) as well as in the region of the canines (p=0.04), second premolars (p=0.01) and first molars (p<0.01) of the mandible. The buccal corridor decreased significantly in the non-extraction group (p<0.01). Conclusion: Premolar extraction in combination with Damon self-ligating system did not lead to reduction of the dental arch width in the maxilla, nor did it increase the size of the buccal corridors.


RESUMO Introdução: Extrair ou não extrair dentes é uma decisão crucial no tratamento ortodôntico. Objetivo: O objetivo do presente estudo foi investigar as alterações na largura da arcada dentária e no corredor bucal após o tratamento ortodôntico com extração e o tratamento sem extração com o sistema autoligável Damon. Material e Métodos: Esse estudo retrospectivo consistiu de 35 pacientes (20 do sexo feminino e 15 do sexo masculino, com idade média de 12,5 anos), tratados com extração de 4 ou 2 pré-molares; e 37 pacientes (16 do sexo feminino e 21 do sexo masculino, com idade média de 12,8 anos), tratados sem extração de pré-molares. Ambos os grupos foram tratados com o sistema autoligável Damon. Os modelos de gesso antes (T0) e depois (T1) do tratamento foram medidos, e os valores de largura da arcada foram determinados ao nível dos primeiros molares, segundos pré-molares, caninos e rugas palatinas. A largura do corredor bucal foi medida usando as imagens extrabucais em T0 e T1. O teste t pareado foi usado para a análise dos dados com distribuição normal, e o teste U de Wilcoxon Mann-Whitney foi usado para os dados com distribuição não normal. Valores de p < 0,05 foram considerados estatisticamente significativos. Resultados: A distância intercaninos superiores aumentou significativamente em ambos os grupos (p<0,01). No grupo sem extração, a largura da arcada aumentou significativamente na região dos segundos pré-molares e primeiros molares superiores (p<0,01), bem como na região dos caninos (p=0,04), segundos pré-molares (p=0,01) e primeiros molares (p<0,01) inferiores. O corredor bucal diminuiu significativamente no grupo sem extração (p<0,01). Conclusão: A extração de pré-molares em combinação com o sistema autoligável Damon não levou à redução na largura da arcada dentária superior, nem aumentou o tamanho dos corredores bucais.

4.
J. oral res. (Impresa) ; 11(4): 1-16, jul. 21, 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1427359

RESUMO

Aim: The aim of this review was to systematically assess and report the effectiveness of chlorhexidine (CHX) mouthwash in preventing plaque accumulation and gingivitis in patients undergoing orthodontic treatment. Material and Methods: The review was prepared according to the Preferred Reporting Items for Systematic Reviews (PRISMA) guidelines and registered under PROSPERO database (CRD42020170776). Four electronic databases were systematically searched along with a complimentary manual search of orthodontic journals until June 2022. Only Randomized Control Trials (RCTs) reporting on antiplaque and antigingivitis efficacy of Chlorhexidine mouthwash compared with placebo or control in orthodontic patients were included. Risk of bias assessment was done using Cochrane ROB-2. Quantitative analysis (Random-Effects Model and Standard Mean Difference (SMD)) with 95 % confidence interval was used. Results: Six RCTs were included for qualitative analysis and four were included for quantitative analysis with a total of 211 participants. Out of six studies, 3 were judged to have a low risk of bias, two had some concerns and one of them had high risk of bias. Random effects meta-analysis performed for anti-plaque effect reported a significant reduction of -1.2 SMD for CHX at 4 to 6 weeks with low heterogeneity (I2-35%). The anti-gingivitis effect at 4 to 6 weeks was significant for CHX with a SMD of -1.03 and a moderate heterogeneity (I2-65%). Conclusion: On analyzing the available evidence a moderate level of certainty supports a short-term reduction in plaque accumulation and gingivitis in orthodontic patients subjected to rinsing with chlorhexidine oral rinse.


Objetivo: El objetivo de esta revisión fue evaluar e informar sistemáticamente la efectividad del enjuague bucal con clorhexidina (CHX) para prevenir la acumulación de placa y la gingivitis en pacientes que reciben tratamiento de ortodoncia. Material y Métodos: La revisión se preparó de acuerdo con las pautas de Preferred Reporting Items for Systematic Reviews (PRISMA) y se registró en la base de datos PROSPERO (CRD42020170776). Se realizaron búsquedas sistemáticas en cuatro bases de datos electrónicas junto con una búsqueda manual gratuita de revistas de ortodoncia hasta junio de 2022. Solo se incluyeron ensayos controlados aleatorios (ECA) que informaron sobre la eficacia antiplaca y antigingivitis del enjuague bucal con clorhexidina en comparación con placebo o control en pacientes de ortodoncia. La evaluación del riesgo de sesgo se realizó mediante Cochrane ROB-2. Se utilizó un análisis cuantitativo (modelo de efectos aleatorios y diferencia de medias estándar (SMD)) con un intervalo de confianza del 95 %. Resultados: Se incluyeron seis ECA para el análisis cualitativo y cuatro para el análisis cuantitativo con un total de 211 participantes. De los seis estudios, se consideró que tres tenían un bajo riesgo de sesgo, dos tenían algunas preocupaciones y uno de ellos tenía un alto riesgo de sesgo. El metanálisis de efectos aleatorios realizado para el efecto antiplaca informó una reducción significativa de -1,2 SMD para CHX a las 4 a 6 semanas con baja heterogeneidad (I2-35%). El efecto antigingivitis a las 4 a 6 semanas fue significativo para CHX con una SMD de -1,03 y una heterogeneidad moderada (I2-65%). Conclusión: Al analizar la evidencia disponible, un nivel de certeza moderado apoya una reducción a corto plazo en la acumulación de placa y gingivitis en pacientes ortodóncicos sometidos a enjuague con enjuague bucal con clorhexidina.


Assuntos
Humanos , Placa Dentária/prevenção & controle , Gengivite/prevenção & controle , Ortodontia , Clorexidina/uso terapêutico , Aparelhos Ortodônticos Fixos , Antissépticos Bucais/uso terapêutico
5.
Arch. méd. Camaguey ; 26: e8336, 2022. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1403276

RESUMO

RESUMEN Introducción: En sus inicios la mayoría de los aparatos funcionales fueron removibles, pero cada día más se incrementan los fijos. Su combinación puede incrementar la eficacia en el tratamiento del retrognatimo mandibular. Objetivo: Presentar los resultados del tratamiento con el botón de Nance modificado en una paciente con retrognatismo mandibular. Caso clínico: Paciente femenina de 13 años de edad, que presenta perfil convexo, disfunción neuromuscular, dentición permanente en ambos maxilares con presencia de ligero apiñamiento anterior, relación molar bilateral de distoclusión de ½ unidad, resalte y sobrepase incisivos de 6 mm, mala relación intermaxilar causada por retrognatismo de la mandíbula y escaso remanente de crecimiento mandibular activo. La primera etapa del tratamiento, incluyó psicoterapia, mioterapia y avance mandibular con un aparato funcional fijo (botón de Nance modificado para la propulsión mandibular). A los nueve meses de iniciar el tratamiento se comprobó el cambio en las relaciones intermaxilares en sentido antero-posterior, con disminución del ángulo ANB hasta 20 e incremento del SNB a 78, como reflejo de una buena relación de las bases ósea por crecimiento mandibular. Conclusiones: El tratamiento realizado a la paciente con el botón de Nance modificado para la propulsión mandibular, permitió la obtención de relaciones intermaxilares favorables.


ABSTRACT Introduction: In the beginning, most of the functional appliances were removable, but the fixed ones are increasing every day. Their combination can increase the effectiveness in the treatment of mandibular retrognathymus. Objective: To present the results of the treatment of a patient with mandibular retrognathism treated with the modified Nance button. Case report: A 13-year-old female patient with convex profile, neuromuscular dysfunction, permanent dentition in both jaws with the presence of slight anterior crowding, bilateral distoclusion molar ratio of ½ unit, incisor protrusion and overhang of 6 mm, poor intermaxillary relationship caused by retrognathism of the mandible and little remnant of active mandibular growth. The first stage of treatment included psychotherapy, myotherapy and mandibular advancement with a fixed functional appliance (modified Nance button for mandibular propulsion). Nine months after starting the treatment, the change in the intermaxillary relationships in the anteroposterior direction was verified, with a decrease in the ANB angle to 20 and an increase in the SNB to 78, as a reflection of a good relationship of the bone bases due to mandibular growth. Conclusions: One year after treatment with the modified Nance button for mandibular propulsion, a correct relationship of the patient's bone bases was achieved.

6.
Gac. méd. espirit ; 23(3): [13], dic. 2021.
Artigo em Espanhol | LILACS | ID: biblio-1404881

RESUMO

RESUMEN Fundamento: El estudio sobre los aparatos actuales de la ortopedia funcional de los maxilares puede aportar nuevos conocimientos para el perfeccionamiento del tratamiento de pacientes con retrognatismo mandibular. Objetivo: Profundizar en los nuevos aparatos de la ortopedia funcional de los maxilares para el tratamiento de pacientes con retrognatismo mandibular. Desarrollo: Se realizó una revisión bibliográfica en las bases de datos SciELO, PubMed, Ebsco, Cumed y Lilacs. En la búsqueda se revisaron 37 artículos, de ellos más del 80 % son de los últimos cinco años. Se identificaron bases teóricas de la ortopedia funcional de los maxilares en el tratamiento de pacientes con retrognatismo mandibular y los aparatos que se utilizan en la actualidad. Conclusiones: Existen nuevas opciones de aparatos funcionales, en su mayoría fijos y clasificados como dentosoportados pasivos, para el tratamiento de pacientes con retrognatismo mandibular.


ABSTRACT Background: The study of the current jaw functional orthopedic appliances can provide new knowledge for the improvement of the patients' treatment with mandibular retrognathia. Objective: To study deeply the current jaw functional orthopedic appliances for the patients' treatment with mandibular retrognathia. Development: A bibliographic review was conducted in the SciELO, PubMed, Ebsco, Cumed and Lilacs databases. A total of 37 articles were reviewed, more than 80 % from the last five years. Theoretical bases on the jaw functional orthopedics in the patients' treatment with mandibular retrognathia and current appliances in use were identified. Conclusions: New functional appliance options, mostly fixed and classified as passive dent supportive, are available for the patients' treatment with mandibular retrognathia.


Assuntos
Aparelhos Ortodônticos , Retrognatismo , Aparelhos Ativadores , Avanço Mandibular , Aparelhos Ortodônticos Fixos
7.
Rev. Nav. Odontol. On Line ; 48(2): 70-79, 20 nov. 2021.
Artigo em Português, Inglês | LILACS-Express | LILACS | ID: biblio-1519254

RESUMO

Com intuito de pontuar os paralelos entre as técnicas ortodônticas com aparelhagem fixa e alinhadores transparentes, este estudo propôs revisar a literatura científica sobre alinhadores ortodônticos removíveis versus aparelhos ortodônticos fixos. Foram selecionados artigos de 2005 a 2021, utilizando as bases de dados PubMed, Scopus, Web of Science, Cochrane Library, Clinical Trials e Opengrey. Os artigos abordavam temáticas como sensação dolorosa, saúde periodontal, higiene, microbiota, reabsorção radicular, qualidade de vida e efetividade do tratamento. Os alinhadores apresentaram maior aceitabilidade pelos pacientes e vantagens claras em relação à dor, higiene, qualidade de vida, reabsorção radicular e saúde periodontal, sendo inferior aos aparelhos ortodônticos fixos na efetividade do tratamento e na interferência na fala.


In order to point out the parallels between orthodontic techniques with fixed appliances and transparent aligners, this study proposed to review the scientific literature on removable orthodontic aligners versus fixed orthodontic appliances. Articles from 2005 to 2021 were selected, using the PubMed, Scopus, Web of Science, Cochrane Library, Clinical Trials and OpenGrey databases. The articles addressed issues such as pain, periodontal health, hygiene, microbiota, root resorption, quality of life and treatment effectiveness. Aligners showed greater acceptability by patients and clear advantages in relation to pain, hygiene, quality of life, root resorption and periodontal health, being inferior to fixed orthodontic appliances in terms of effectiveness and speech capacity.

8.
J. oral res. (Impresa) ; 10(3): 1-10, jun. 30, 2021. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1390974

RESUMO

Introduction: Dental malocclusion is a public health problem and orthodontics is the specialty in charge of diagnosing and treating it, aesthetic brackets are an alternative, the costs are varied, which makes its precision doubtful. Objective: Evaluate the measurement and geometry of the slot of three brands of aesthetic brackets and verify their precision. Material and Methods: Twenty-four aesthetic Roth prescription 0.022" slot polycrystalline ceramic brackets were evaluated in three brands: American Orthodontics (United States), Morelli (Brazil) and Class One (China). Eight samples were measured per group in a specialized laboratory certified in measurement and calibration, the measurements of internal and external height were verified, per mesial and distal; and the parallelism of the slot of each bracket. The results were processed with SPSS 22 and tests of variance (ANOVA), Tukey and Student's t were used. Results:The measurements of the brackets' grooves do not correspond to the measurements announced by the manufacturers, these are greater, however, American Orthodontics is within the tolerance range (p<0.01); the slots in the mesio-distal direction and the lingual vestibule are not parallel in Morelli and Class One. Conclusion: The results of this study indicate that the slots of the supports are oversized, their geometry is not precise and varies greatly between brands and prices. The three-dimensional control of the tooth could be compromised.


Introducción: La maloclusión dental es un problema de salud pública y la ortodoncia es la especialidad encargada de diagnosticarla y tratarla, los brackets estéticos son una alternativa, los costos son variados lo que hace dudar su precisión. Objetivo: Evaluar la medida y geometría de la ranura de tres marcas de brackets estéticos y corroborar su precisión. Material y Métodos: Se evaluaron 24 brackets estéticos cerámicos policristalinos de ranura 0,022" prescripción Roth en tres marcas: American Orthodontics (Estados Unidos), Morelli (Brasil) y Class One (China). Se midieron ocho muestras por grupo en un laboratorio especializado y certificado en medición y calibración, se verificaron las medidas de altura interna y externa, por mesial y distal; y el paralelismo de la ranura de cada brackets. Los resultados fueron procesados con SPSS 22 y se utilizaron pruebas de varianza (ANOVA), Tukey y t de Student. Resultados: Las medidas de las ranuras de los brackets no se corresponden con la medida anunciada por los fabricantes, estas son mayores, sin embargo, American Orthodontics y Morelli se encuentra dentro del rango de tolerancia (p<0,01); las ranuras en sentido mesio distal y vestíbulo lingual no son paralelas estadísticamente en Morelli y Class One. Conclusión: Los resultados de este estudio indican que las ranuras de los soportes se encuentran sobredimensionadas, su geometría no es precisa y varía mucho entre marcas y precios. El control tridimensional del diente se podría ver comprometido.


Assuntos
Humanos , Ortodontia Corretiva/métodos , Braquetes Ortodônticos , Desenho de Aparelho Ortodôntico , Cerâmica , Estudos Transversais , Má Oclusão
9.
Rio de Janeiro; s.n; 2021. 62 p. tab, ilus.
Tese em Português | BBO - Odontologia | ID: biblio-1428389

RESUMO

Objetivou-se neste estudo, avaliar o conteúdo de vídeos do YouTube publicados por brasileiros que abordam a experiência do uso de aparelho fixo, sinalizando a percepção de aspectos estéticos, psicoemocionais e sociais relacionados ao tratamento ortodôntico, avaliando o perfil dos autores e veracidade das informações apresentadas. Foi gerada uma lista de vídeos a partir do termo "tirei meu aparelho", e selecionados 100 canais do YouTube que abordassem a experiência ortodôntica vivenciada pelos youtubers. Foram excluídos vídeos que não apresentassem uso de aparelho fixo e casos em que o aparelho foi removido antes do tempo preconizado. As variáveis avaliadas incluíam a percepção estética dentária antes, durante e após o uso do aparelho, dor, dificuldade de alimentação e higienização bem como relação com o profissional e informações dadas pelo youtuber. Os 10 vídeos mais vistos, ultrapassaram 7,5 milhões de visualizações. Observou-se maior prevalência de vídeos postados por mulheres (85%), adolescentes entre 11 e 18 anos (55%), utilizando aparelho fixo metálico (92%). Quanto à percepção estética prévia, 72% relataram estar insatisfeitos, após o tratamento, 86% ficaram satisfeitos. Quanto a alimentação e higienização 51% e 35% respectivamente tiveram percepção negativa. Presença de dor por ulceração foi relatada em 57% dos casos e por movimentação em 35% dos casos. Apenas 3 casos mencionaram insatisfação com o profissional. Informações quanto à aparelhos autoligados e extrações dentárias divergiam da ciência baseada em evidência. Com base nos resultados obtidos observou-se relatos de dor, dificuldade de alimentação e higienização foram temas recorrentes, bem como bom relacionamento com profissional, insatisfação estética anterior ao tratamento e satisfação estética após tratamento. Houve predomínio de vídeos postados por mulheres, adolescentes. Informações sem base científica referente à aparelhos autoligados e extrações dentárias foram encontradas. (AU)


The objective of this study was to investigate the content of YouTube videos published by Brazilians that address the experience of using a fixed appliance, signaling the perception of aesthetic, psychoemotional and social aspects related to orthodontic treatment, evaluating the profile of the authors and the veracity of the information presented. The analyzed sample was obtained through the search results of the phrase "tirei meu aparelho" ("I took off my appliance"), from which 100 YouTube channels were selected that addressed the orthodontic experience experienced by youtubers. Videos that did not show the use of a fixed appliance and cases in which the appliance was removed before the recommended time were excluded. The analyzed variables were the dental aesthetic perception before, during and after the use of the appliance, pain, difficulty of feeding and cleaning, as well as the relationship with the professional and accuracy of the technical information provided by the youtuber. The most 10 viewed videos surpassed 7.5 million views. There was a higher prevalence of videos posted by women (85%), adolescents between 11 and 18 years old (55%) using fixed metallic braces (92%). As for aesthetic perception, 72% reported being dissatisfied before the treatment and 86% were satisfied after the treatment. As for feed and sanitation, 51% and 35% had a negative perception, respectively. Presence of pain due to ulceration was reported in 57% of cases, whereas pain due to movement in 35% of cases. Only 3 cases mentioned dissatisfaction with the professional. Technical information on self-ligating and tooth extractions diverged from evidence-based Science. Based on the results obtained, there is a greater tendency of reports by female adolescents using metallic braces, expressing pain, feeding and hygiene difficulties, with good relationship with the professional, esthetic dissatisfaction before treatment and esthetic satisfaction after treatment were observed. Unscientific information regarding self-ligating appliances and tooth extractions was found. (AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Percepção , Satisfação Pessoal , Recursos Audiovisuais , Rede Social , Aparelhos Ortodônticos Fixos , Dor , Estética Dentária/psicologia
10.
Pesqui. bras. odontopediatria clín. integr ; 21(supl.1): e0032, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1351223

RESUMO

ABSTRACT Objective: To investigate the effectiveness of Suresmile® lingual therapy on torque, tip, and rotations measures through digital evaluation of planning and post-treatment digital models. Material and Methods: A sample of 12 Caucasian adult patients (4 men; mean age 30.6 years ± 3.9 and 8 women; mean age 31.4 years ± 4.5) treated with the Suresmile® lingual orthodontic technique was retrospectively selected, regardless of the type of malocclusion. Digital planning was performed with Suresmile® software, while lingual therapy was accomplished with interactive self-ligating lingual brackets and customized Suresmile® arches. First, digital models of planning and post-treatment digital models were compared using VAM software (and the discrepancies were analyzed through MANOVA and four multivariate. Then, Tukey and Bonferroni's post-hoc tests are performed. Results: The accuracy average values are 60.11 ± 27.67% for torque, 53.52 ± 27.37% for tip and 59.19 ± 26.42% for rotation, while for inaccuracy values are 2.72° ± 2.23° for torque, 2.98° ± 2.16°for tip and 3.58° ± 3.29° for rotation. No significant differences have been recorded evaluating different sectors of both arches. Conclusion: This retrospective preliminary study highlight how overcorrections, especially in the Suresmile lingual technique, should be performed during orthodontic planning. Moreover, the study gets bases for further, more structured future studies that should involve larger and more homogeneous samples.


Assuntos
Humanos , Feminino , Adulto , Braquetes Ortodônticos , Oclusão Dentária , Estética Dentária , Aparelhos Ortodônticos Fixos , Má Oclusão , Projetos Piloto , Análise Multivariada , Estudos Retrospectivos , Estatísticas não Paramétricas , Itália
11.
Rev. Ateneo Argent. Odontol ; 63(2): 34-38, nov. 2020. ilus
Artigo em Espanhol | LILACS | ID: biblio-1150681

RESUMO

La evolución de la ortodoncia, desde sus inicios, ha demostrado hechos destacables como el surgimiento de la técnica de arco recto, el desarrollo de prescripciones variadas, el uso de ranuras con diferentes dimensiones, sistemas de anclaje esquelético, tomografía... A pesar de ello, los diseños y las características que presentaban los brackets eran siempre los mismos y limitados. La historia de las grandes ideas es vasta, pero debían estar unidas en una sola pieza. Esto es lo que hicieron los autores de este artículo, al desarrollar un nuevo diseño de bracket que cuenta con dos slots centrales y cada una con diferentes dimensiones, un slot tiene dimensiones de 0.018 "X 0.030" y el otro 0.022 "X 0.028", abriéndse una gama de posibilidades. A partir de ahora contamos con una herramienta de trabajo con varios recursos, que genera grandes beneficios para profesionales y pacientes, y que gana cada día más seguidores (AU)


The evolution of orthodontics, since its beginnings, has demonstrated remarkable events such as the appearance of the straight wire technique, the development of varied prescriptions, the use of slots with different dimensions, skeletal anchoring systems, tomography ... Despite this, the designs and the features that the brackets presented were always the same and limited. The history of great ideas is vast, but they needed to be united in one piece. This is what the authors of this article did, when developing a new bracket design that features two central slots and each with different dimensions, one slot has dimensions of 0.018 "X 0.030" and the other 0.022 "X 0.028" with a fan of possibilities is being opened. Now, a work tool with several resources, which generates great benefits for professionals and patients is gaining more followers every day (AU)


Assuntos
Humanos , Ortodontia Corretiva , Braquetes Ortodônticos , Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos Fixos
12.
Rev. Nav. Odontol. On Line ; 47(1): 45-53, 12 jun. 2020.
Artigo em Português, Inglês | LILACS-Express | LILACS | ID: biblio-1363521

RESUMO

Com o intuito de obter resultados clínicos cada vez mais precisos nos tratamentos ortodônticos, as novas tecnologias de colagem in- direta têm assumido um papel relevante na Ortodontia. Com o desenvolvimento dos meios de obtenção e manipulação das imagens digitais, surgiu a possibilidade de realizar o planejamento ortodôntico no ambiente virtual, simulando o resultado desejado, bem como o melhor posicionamento dos acessórios ortodônticos nos dentes para atingir esse objetivo. A possibilidade de impressão tridimensional a partir da tecnologia CAD/CAM permitiu que a guia para a transferência dos bráquetes, na colagem indireta, fosse confeccionada diretamente no software após planejamento digital da posição dos mesmos. Atualmente, algumas empresas têm disponibilizado pro- gramas ou ofertado a possibilidade de executar planejamento digital, bráquetes customizados, arcos personalizados e guias para a colagem indireta. Este artigo tem o objetivo de realizar uma revisão de literatura reunindo informações recentes sobre colagem indireta utilizando o sistema CAD/CAM em relação à precisão de colagem e tempo do tratamento ortodôntico. Conclui-se que a colagem indireta por meio de sistemas CAD-CAM apresenta confiabilidade em relação à precisão do posicionamento dos bráquetes.Em relação ao tempo de tratamento, diversos estudos sugerem que este foi reduzido com o método, porém, a variedade de técnicas e softwares existentes, além da diversidade dos métodos científicos, indicam a necessidade de mais investigações. Apesar disso, a colagem indireta digital tem se mostrado uma opção interessante a ser incorporada ao tratamento ortodôntico.


New indirect bonding technologies have assumed an important role in Orthodontics to obtain increasingly accurate clinical results in orthodontic treatments. With the development of means of obtaining and manipulating digital images, the possibility to carry out orthodontic planning in the virtual environment arose, simulating the desired result, as well as the best positioning of orthodontic accessories on teeth to achieve this goal. The possibility of three-dimensional printing using CAD/CAM technology allowed the guide for the transfer of brackets, in indirect bonding, to be made directly in the software after digital planning of their position. Currently, some companies have made programs available or offered the possibility of executing digital planning, customized brackets, personalized arches and guides for indirect bonding. This article aims to perform a literature review, gathering recent information on indirect bonding using the CAD/CAM system in relation to bonding accuracy and time of orthodontic treatment. It is concluded that the indirect bonding using CAD/CAM systems presents reliability in relation to the precision of the positioning of brackets. Regarding the treatment time, several studies suggest that it was reduced with the method, however, the variety of existing techniques and software, in addition to the diversity of scientific methods, indicate the need for further investigations. Despite this, indirect digital bonding has proved to be an interesting option to be incorporated into orthodontic treatment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA