1.
Talanta ; 125: 196-203, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24840433

RESUMO

A new headspace solid-phase micro-extraction (HS-SPME) method followed by gas chromatography with pulsed flame photometric detection (GC-PFPD) analysis has been developed for the simultaneous determination of 11 organotin compounds, including methyl-, butyl-, phenyl- and octyltin derivates, in human urine. The methodology has been validated by the analysis of urine samples fortified with all analytes at different concentration levels, and recovery rates above 87% and relative precisions between 2% and 7% were obtained. Additionally, an experimental-design approach has been used to model the storage stability of organotin compounds in human urine, demonstrating that organotins are highly degraded in this medium, although their stability is satisfactory during the first 4 days of storage at 4 °C and pH=4. Finally, this methodology was applied to urine samples collected from harbor workers exposed to antifouling paints; methyl- and butyltins were detected, confirming human exposure in this type of work environment.


Assuntos
Cromatografia Gasosa , Compostos Orgânicos de Estanho/urina , Microextração em Fase Sólida , Urinálise/instrumentação , Urinálise/métodos , Humanos , Fotometria , Reprodutibilidade dos Testes , Extração em Fase Sólida , Temperatura , Volatilização , Poluentes Químicos da Água/análise