Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Microsc Res Tech ; 86(12): 1635-1641, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37587834

RESUMO

This study evaluated the cyclic and torsional fatigue resistance of a new nickel-titanium (Flat File 25.04) instrument on the continuous and reciprocating motion. Sixty instruments of the ProDesign Logic2 25.03 and 25.05 (Easy Equipamentos Odontológicos, Belo Horizonte, Brazil), and MK Flat File 25.04 (n = 20) (MK Life, Porto Alegre, Brazil) were used. For the cyclic fatigue test, an artificial stainless steel simulated canal with an angle of 60° and a radius of curvature of 5 mm located 5 mm from its tip was used. The torque and rotation angle at the instruments' failure on the torsional fatigue test was based on the ISO 3630-1 protocol, in which the 3 mm tip of each instrument was fixed and connected to an electric motor and a load cell. The fractured surface of each fragment was examined by scanning electron microscopy. Data were analyzed using a 1-way analysis of variance and Tukey's test with a significance level of 5%. Flat File 25.04 had lower cyclic fatigue in both kinematics than the Logic instruments (p < .05). Reciprocating motion improved the cyclic fatigue of the tested instruments (p < .05). Flat File 25.04 had similar torque to Logic2 25.05 (p > .05), and both were superior to Logic2 25.03 (p < .05). The angular deflection values were different for the three tested instruments (p < .05), in the decreasing order: Logic2 25.03, 25.05, and Flat File 25.04. Flat File presented good resistance to cyclic and torsional fatigue resistance. Reciprocating motion improved the cyclic fatigue resistance of the instruments and can be considered when using programmable motors. RESEARCH HIGHLIGHTS: Scanning electron microscopy evaluation of different endodontic rotary file and fatigue resistance tests.

2.
Sensors (Basel) ; 22(20)2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36298397

RESUMO

Shape memory alloy (SMA) micro cables have a wide potential for attenuation of vibrations and structural health monitoring due to energy dissipation. This work evaluates the effect of SMA thermomechanical coupling during dynamic cycling and the fatigue life of NiTi SMA micro cables submitted to tensile loadings at frequencies from 0.25 Hz to 10 Hz. The thermomechanical coupling was characterized using a previously developed methodology that identifies the self-heating frequency. When dynamically loaded above this frequency, the micro cable response is dominated by the self-heating, stiffening significantly during cycling. Once above the self-heating frequency, structural and functional fatigues of the micro cable were evaluated as a function of the loading frequency for the failure of each individual wire. All tests were performed on a single wire with equal cross-section area for comparison purposes. We observed that the micro cable's functional properties regarding energy dissipation capacity decreased throughout the cycles with increasing frequency. Due to the additional friction between the filaments of the micro cable, this dissipation capacity is superior to that of the single wire. Although its fatigue life is shorter, its delayed failure compared to a single wire makes it a more reliable sensor for structural health monitoring.


Assuntos
Ligas de Memória da Forma , Titânio , Humanos , Teste de Materiais , Estresse Mecânico , Titânio/química , Fadiga
3.
Braz. dent. j ; Braz. dent. j;33(4): 47-53, July-Aug. 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1394087

RESUMO

Resumo O presente estudo teve como objetivo realizar dois tratamentos térmicos diferentes em instrumentos de NiTi austenítico ProFile e comparar o desempenho mecânico de instrumentos originais e tratados termicamente. O tratamento térmico dos instrumentos ProFile (tamanho de ponta 25 e conicidade 0.06) foi realizado em um forno em atmosfera de argônio usando uma taxa de aquecimento de 10°C/min. Após atingir as temperaturas programadas de 450 ºC ou 500 ºC o sistema permaneceu em temperatura constante por 10 minutos; seguido de resfriamento em água à temperatura ambiente. Em seguida; os três grupos de instrumentos (n=30 por grupo) foram comparados quanto à fadiga cíclica (n=10 por grupo); flexão (n=10 por grupo) e resistência à flambagem (n=10 por grupo). Após testes de fadiga cíclica; um microscópio eletrônico de varredura foi utilizado para analisar as superfícies de fratura e observar o modo de fratura. A análise estatística foi realizada por meio dos testes de One-way ANOVA e teste de Student-Newman-Keuls; com erro de tipo alfa fixado em 0.05. Coloração amarelada e azulada foi observada nos instrumentos ProFile após tratamentos térmicos a 450 ºC ou 500 ºC; respectivamente. Os instrumentos ProFile originais apresentaram menor fadiga cíclica e maior resistência à flexão e flambagem (P<0.05). Em contraste; os instrumentos ProFile azulados (tratados termicamente a 500°C) apresentaram maior fadiga cíclica e menor resistência à flexão e flambagem (P>0.05). Pode-se concluir que os diferentes tratamentos térmicos realizados nos instrumentos ProFile aumentaram sua resistência à fadiga cíclica e melhoraram a flexibilidade e resistência à flambagem.


Abstract The present study aimed to perform two different heat-treatments in an austenitic NiTi ProFile instrument and to compare the mechanical performance of original and heat-treated instruments. Heat treatment of ProFile (tip size 25 and 0.06 taper) instruments were carried out in a furnace in argon atmosphere using a heating rate of 10° C/min. After reaching the programmed temperatures of 450 ºC or 500 ºC the system remained at a constant temperature for 10 minutes; followed by cooling in water at room temperature. Afterwards; the three groups (n=30 per group) of instruments were compared regarding their cyclic fatigue (n=10 per group); bending (n=10 per group); and buckling resistance (n=10 per group). After cyclic fatigue tests; a scanning electron microscope was used to analyze the fracture surfaces and observe the fracture mode. Statistical analysis was performed using One-way ANOVA and Student-Newman-Keuls test; with an alpha type error set at 0.05. Yellowish and blueish coloration was observed in the ProFile instruments after 450 ºC or 500 ºC heat treatments; respectively. Conventional ProFile instruments showed the lower cyclic fatigue; and the higher bending and buckling resistance (P<0.05). In contrast; yellowish ProFile instruments (heat treated at 500° C) showed the higher cyclic fatigue; and the lower bending and buckling resistance (P>0.05). It can be concluded that the different heat treatments performed on ProFile instruments increased its cyclic fatigue resistance and improved the flexibility and buckling resistance.

4.
J Vet Dent ; 39(3): 257-268, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35585702

RESUMO

This article reviews the historical development, properties, and trends of nickel titanium rotary instrumentation use for the veterinary endodontist.


Assuntos
Preparo de Canal Radicular , Titânio , Ligas , Animais , Desenho de Equipamento/veterinária , Preparo de Canal Radicular/veterinária
5.
Clin Oral Investig ; 26(5): 3939-3947, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35039941

RESUMO

OBJECTIVES: This study aims to evaluate the effects of cyclic loading on the bending moments and the developed stress state of austenitic and R-phase endodontic files through finite element analysis. MATERIALS AND METHODS: The mechanical properties of two groups of NiTi wires, austenite and R-phase, were measured in samples at two different conditions: uncycled and cycled. The cycled condition was achieved by subjecting samples of the two groups to 80% of the corresponding fatigue life under rotating bending efforts. The measured mechanical properties were then used in the finite element analysis, where the boundary and loading conditions were set to replicate a standard bending test. RESULTS: The results showed that mechanical cycling leads to decreasing stress levels and bending moments in the simulated files, especially in the austenitic ones. In comparison with austenite, R-phase presented a more stable mechanical behavior during cycling. CONCLUSIONS: The results show that the moment and stress calculated for an instrument under bending can be considerably decreased after some cyclic work. CLINICAL RELEVANCE: The fatigue related to the clinical use of an endodontic file decreases the moment (as well as the forces) imposed by the instrument during the shaping of a curved root canal. This decrease is directly related to the type of atomic array present in the alloy.


Assuntos
Ligas Dentárias , Titânio , Desenho de Equipamento , Fadiga , Análise de Elementos Finitos , Humanos , Teste de Materiais , Preparo de Canal Radicular , Estresse Mecânico
6.
Sensors (Basel) ; 21(21)2021 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-34770446

RESUMO

The mechanical loading frequency affects the functional properties of shape memory alloys (SMA). Thus, it is crucial to study its effect for the successful use of these materials in dynamic applications. Based on the superelastic cyclic behavior, this work presents an experimental methodology for the determination of the critical frequency of the self-heating of a NiTi Belleville conical spring. For this, cyclic compressive tests were carried out using a universal testing machine with loading frequencies ranging from 0.5 Hz to 10 Hz. The temperature variation during the cyclic tests was monitored using a micro thermocouple glued to the NiTi Belleville spring. Numerical simulations of the spring under quasi-static loadings were performed to assist the analysis. From the experimental methodology applied to the Belleville spring, a self-heating frequency of 1.7 Hz was identified. The self-heating is caused by the latent heat accumulation generated by successive cycles of stress-induced phase transformation in the material. At 2.0 Hz, an increase of 1.2 °C in the average temperature of the SMA device was verified between 1st and 128th superelastic cycles. At 10 Hz, the average temperature increase reached 7.9 °C and caused a 10% increase in the stiffness and 25% decrease in the viscous damping factor. Finally, predicted results of the force as a function of the loading frequency were obtained.


Assuntos
Calefação , Níquel , Ligas , Elasticidade , Teste de Materiais , Temperatura , Titânio
7.
Clin Oral Investig ; 25(6): 3691-3698, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33219876

RESUMO

INTRODUCTION: The aim of the present study was to compare the cyclic fatigue resistance of Reciproc R25 (R25) and Reciproc Blue R25 (R25B) instruments, after simulated clinical use in traditional (TradAC) and ultraconservative (UltraAC) endodontic access cavities. METHODS: Forty mandibular molars were randomly assigned into the following groups, according to the type of access and instrument to be used: TradAC and R25, TradAC and R25B, UltraAC and R25, and UltraAC and R25B. Teeth were accessed accordingly, and the root canals were prepared using "RECIPROC ALL" kinematics. The cyclic fatigue resistance of the forty used instruments was obtained measuring the time to fracture in an artificial stainless-steel canal. Ten brand new R25 and R25B were used as control groups. The fracture surfaces and the side cutting edges of the instruments were examined with a scanning electron microscope. Data were statistically analyzed using one-way ANOVA and post hoc Tukey tests with a significance level of P < 0.05. RESULTS: R25B instruments showed significantly higher cyclic fatigue resistance than R25, regardless of the access cavity type (P < 0.05). No differences were observed in the cyclic fatigue resistance between instruments without simulated clinical use and used in TradAC (P > 0.05). R25 and R25B used in UltraAC showed significantly lower cyclic fatigue resistance compared with the instruments used in TradAC and without simulated clinical use (P < 0.05). CONCLUSIONS: R25B files showed improved cyclic fatigue resistance than R25. The use of R25B and R25 files in mandibular molars with UltraACs decreased their cyclic fatigue resistance, compared with TradAC. CLINICAL RELEVANCE: The use of Reciproc and Reciproc Blue files in mandibular molars with ultra-conservative endodontic access cavities reduced their cyclic fatigue resistance. Clinicians should be aware about the reduced cyclic fatigue resistance of these files when used in mandibular molars with UltraAC, due to the synergistic effect of access angulation and severe curvature induced in the endodontic files.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Aço Inoxidável , Titânio
8.
Aust Endod J ; 47(2): 265-272, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33296137

RESUMO

This study investigated the cyclic fatigue, bending, torsional resistance and angular deflection of Pro-R 25.08, Logic RT 25.08, MK Retreatment 25.08 (MK RT) and ProTaper Retreatment D2 instruments. Cyclic fatigue test was performed until fracture in a custom stainless-steel device with water bath equipment to simulate body temperature. Fracture time was recorded. A number of cycles were calculated. Resistance to bending at 45°, torsional resistance and angular deflection were evaluated. The fracture surfaces were examined by scanning electron microscopy. Statistical analysis was performed with one-way ANOVA and Tukey and Kruskal-Wallis and Dunn tests. Pro-R and Logic RT presented the highest cyclic fatigue (P < 0.05). D2 had higher strength to bend than Pro-R and Logic RT (P < 0.05). Logic RT showed the highest torque and angular deflection (P < 0.05), without differences when compared to D2 (P > 0.05). Instrument performances were dependent on their geometrical features and heat treatments.


Assuntos
Níquel , Titânio , Ligas Dentárias , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Retratamento , Preparo de Canal Radicular , Estresse Mecânico , Torção Mecânica
9.
Belo Horizonte; s.n; 2021. 60 p. ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1392046

RESUMO

O objetivo deste trabalho foi avaliar a resistência à fadiga e a resistência à corrosão em instrumentos endodônticos de NiTi dos sistemas HyFlex EDM, Hyflex CM, e RaCe, além de relacionar estes resultados às características físicas, químicas e estruturais destes instrumentos. Para tal, instrumentos 25/.~ do sistema HyFlex EDM (EDM), instrumentos 30/.06 do sistema HyFlex CM (CM) e RaCe (RC) foram utilizados. A composição química foi determinada por espectroscopia dispersiva de raios-X, as fases presentes nos materiais foram determinadas por difratometria de raios-X (DRX) e as temperaturas de transformação de fases por calorimetria exploratória diferencial (DSC). A análise da rugosidade superficial dos instrumentos foi realizada por microscopia de força atômica (AFM) e a caracterização dimensional dos instrumentos foi realizada através da mensuração do diâmetro a 3mm da ponta. Ensaios de fadiga até a ruptura foram realizados nos três grupos (n=10) e o tempo médio até a fratura determinado. Instrumentos novos foram subdivididos em grupos controle e experimental para cada sistema. Os grupos experimentais foram submetidos à ensaios de fadiga, até 3/4 do tempo médio para a ruptura e posteriormente a testes de corrosão (potencial de circuito aberto e polarização). Os grupos controle foram diretamente submetidos aos mesmos testes de corrosão. A análise de Weibull foi aplicada para avaliação da probabilidade de falha em relação ao tempo nos instrumentos testados em fadiga até a ruptura. Análise de variância com índice de significância de 0,05% foi adotada para os resultados de composição química, temperatura de transformação de fases, diâmetro, rugosidade e testes de corrosão. A composição química foi praticamente equiatomica em instrumentos RaCe, com presença de Níquel e Titânio. Já instrumentos EDM e CM apresentaram, além destes elementos, Oxigênio na composição. A caracterização estrutural evidenciou maiores temperaturas de transformação de fase Af (austenite finish) para os grupos tratados termicamente (CM e EDM), este dado foi comprovado pelos resultados da difratometria de raios-X com a presença de fase-R e austenita (fase ß) à temperatura ambiente para ambos. O grupo RC, apresentou menores temperaturas Af (p<.05), além de apenas austenita na análise por DRX. As medidas de diâmetro apresentaram-se sem diferenças estatisticamente significativas entre os grupos CM e RC, ambos significativamente maiores que EDM. Os testes de fadiga flexural apresentaram tempo até a fratura sem diferença entre EDM e CM (p>0,05) e ambos foram superiores em relação à RC (p<0.05). Por outro lado, a análise de Weibull apresentou melhores parâmetros de confiabilidade para RC e CM. Os ensaios de corrosão apresentaram diferenças significativas entre os sistemas analisados, mas não entre instrumentos novos e ciclados. Os grupos CM apresentaram maior resistência à corrosão, seguido de EDM e RC. A rugosidade superficial foi maior em instrumentos CM, seguidos de EDM e RC. De acordo com os resultados a microestrutura dos instrumentos tratados termicamente melhora a resistência à fadiga e resistência à corrosão, independentemente do tipo de usinagem.


The aim of this study was to assess the fatigue and corrosion resistance of NiTi endodontic instruments. HyFlex EDM 25 /. ~, HyFlex CM 30/.06 and RaCe 30/.06 were used. Chemical composition was determined by energy-dispersive X-ray spectroscopy, phase constitution by X-ray diffraction and transformation temperatures by differential scanning calorimetry. Surface roughness was analyzed by atomic microscopic force (AFM) and the geometric characterization of the instruments was performed by measuring the diameter at 3mm from the tip. Initially, 10 instruments from each group were tested until rupture in the flexural fatigue bench to obtain the mean time until fracture. Then, new instruments were subdivided into control and experimental groups for each system. Experimental groups were subjected to fatigue tests, up to 3/4 of the mean time to rupture and subsequently to corrosion tests. Control groups were directly subjected to the same corrosion tests. Weibull analysis was applied to assess the reliability in the tested instruments to failure. Analysis of variance with a significance of 0.05% was adopted for the results of chemical composition, phase transformation temperature, diameter, roughness, and corrosion tests. The chemical composition was near equiatomic in RaCe instruments, with the presence of Nickel and Titanium. On the other hand, EDM and CM instruments presented, in addition to these elements, Oxygen in the composition. The structural characterization showed higher Af phase transformation temperatures (austenite finish) for the heat-treated groups (CM and EDM), this data was confirmed by the results of X-ray diffractometry with the presence of R-phase and austenite (phase ß) at room temperature for both. The RC group had lower temperatures Af (p<.05), in addition to only austenite in the XRD analysis. Diameter measurements showed no statistically significant differences between the CM and RC groups, both significantly larger than EDM. Flexural fatigue tests showed time to fracture with no difference between EDM and CM (p>0.05) and both were superior to RC (p<0.05). However, the Weibull analysis showed better reliability parameters for RC and CM. The corrosion tests showed significant differences between the analyzed systems, but not between new and cycled instruments. The CM groups showed greater resistance to corrosion, followed by EDM and RC. Surface roughness was higher in CM instruments, followed by EDM and RC. According to the results, the microstructure of the thermally treated instruments improves fatigue resistance and corrosion resistance, regardless of the type of machining.


Assuntos
Teste de Materiais , Corrosão , Instrumentos Odontológicos , Fadiga
10.
Braz. dent. sci ; 24(4): 1-6, 2021. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1337597

RESUMO

Objective: Aim of the present study is to evaluate mechanical properties of a newly developed rotary file, AF Rotary (Fanta Dental, Shanghai, China), and to compare these features with a worldwide spread rotary file, Protaper Gold F2 (PTG F2; Dentsply Maillefer, Ballaigues, Switzerland). Material and Methods: 60 AF Rotary 25.06 and 60 PTG F2 were divided in three groups of 20 files each. A group underwent to cyclic fatigue resistance tests, second group underwent to torsional resistance tests, third group underwent to bending tests. The statistical analysis was performed using t student test with significance level set at 95% (p < 0.05). Results: AF Rotary showed significantly higher torsional resistance and cyclic fatigue resistance (p < 0.05) when compared to the PTG F2. AF Rotary also showed significantly lower bending resistance (p < 0.05) when compared to the PTG F2. Conclusion: Therefore, within the limitations of this study, the results show better performances for AF Rotary compared to PTG F2 regarding the cyclic fatigue test, the torsional test and the bending test. Since the PTG F2 is a commonly used and widely investigated instrument it could be possible to state that the AF Rotary exhibits remarkable in vitro performances. (AU)


Objetivo: O objetivo do presente estudo é avaliar as propriedades mecânicas de uma lima rotativa recém-desenvolvida, AF Rotary (Fanta Dental, Shanghai, China), e comparar essas características com uma lima rotativa mundialmente difundida, Protaper Gold F2 (PTG F2; Dentsply Maillefer, Ballaigues, Suíça). Material e Métodos: 60 AF Rotary 25.06 e 60 PTG F2 foram divididos em três grupos de 20 arquivos cada. Um grupo foi submetido a testes de resistência à fadiga cíclica, o segundo grupo foi submetido a testes de resistência à torção, o terceiro grupo foi submetido a testes de flexão. A análise estatística foi realizada por meio do teste t student com nível de significância de 95% (p <0,05). Resultados: AF Rotary apresentou resistência torcional e resistência à fadiga cíclica significativamente maiores (p <0,05) quando comparado ao PTG F2. AF Rotary também apresentou resistência à flexão significativamente menor (p <0,05) quando comparado ao PTG F2. Conclusão: Portanto, dentro das limitações deste estudo, os resultados mostram melhores desempenhos do AF Rotary em relação ao PTG F2 no que diz respeito ao teste de fadiga cíclica, ao teste de torção e ao teste de flexão. Uma vez que o PTG F2 é um instrumento comumente usado e amplamente investigado, pode-se afirmar que o AF Rotary exibe desempenhos in vitro notáveis. (AU)


Assuntos
Resistência à Flexão , Testes Mecânicos
11.
Dental press j. orthod. (Impr.) ; 26(2): e212020, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1249707

RESUMO

ABSTRACT Introduction: After debonding, white spot may appear on the area below the bracket, which is the early clinical sign of carious lesion. There is increased caries risk underneath and adjacent to orthodontic bands and brackets, which call for maximum use of caries preventive procedures using various fluoride application methods. Objective: The aim of the study was to evaluate alterations in the mechanical properties (modulus of elasticity and yield strength) in loading and unloading phases for different orthodontic archwires (nickel-titanium [NiTi] and copper-nickel-titanium [CuNiTi]) when exposed routinely to fluoride prophylactic agents for a predetermined period of time. Methods: Preformed rectangular NiTi and CuNiTi wires were immersed in fluoride solution and artificial saliva (control) for 90 minutes at 37ºC. After immersion, specimens were tested using a 3-point bend test on a universal testing machine. Results: There is a significant reduction in the unloading yield strength when the NiTi and CuNiTi wires were exposed to APF gel. Conclusion: The result suggests that use of topical fluoride agents affect the mechanical properties of the wires, leading to increase in treatment duration. Fluoride prophylactic agents must be used with caution in patients undergoing orthodontic treatment. Injudicious use of these agents may cause corrosive effects on the orthodontic wire surfaces, with alteration in their mechanical properties.


RESUMO Introdução: Após a remoção dos braquetes, manchas brancas podem aparecer na área embaixo deles, as quais são o sinal clínico inicial da lesão cariosa. Existe um maior risco de cáries embaixo e ao redor das bandas e braquetes ortodônticos, o que exige a máxima utilização de procedimentos preventivos de cárie, usando diferentes métodos com aplicação de flúor. Objetivo: O objetivo do presente estudo foi avaliar alterações nas propriedades mecânicas (módulo de elasticidade e resistência ao escoamento), nas fases de carregamento e descarregamento de diferentes fios ortodônticos (níquel-titânio [NiTi] e níquel-titânio com adição de cobre [CuNiTi]), quando expostos rotineiramente a agentes profiláticos fluoretados, utilizados durante um período de tempo predeterminado. Métodos: Os fios pré-contornados retangulares de NiTi e CuNiTi foram imersos em solução fluoretada e saliva artificial (controle) durante 90 minutos a 37°C. Após a imersão, as amostras foram testadas utilizando-se um teste de flexão em três pontos, em uma máquina universal de testes. Resultados: Houve uma redução significativa na resistência ao escoamento na fase de descarregamento quando os fios de NiTi e CuNiTi foram expostos ao gel fluoretado. Conclusão: O resultado sugere que o uso tópico de agentes fluoretados afeta as propriedades mecânicas dos fios, levando a um aumento na duração do tratamento. Os agentes profiláticos fluoretados devem ser utilizados com cautela em pacientes submetidos a tratamento ortodôntico. O uso indiscriminado desses agentes pode causar efeitos corrosivos na superfície dos fios ortodônticos e consequente alteração das suas propriedades mecânicas.


Assuntos
Humanos , Fios Ortodônticos , Cobre , Ligas Dentárias , Fluoretos , Níquel , Propriedades de Superfície , Titânio , Teste de Materiais , Níquel/efeitos adversos
12.
J Mech Behav Biomed Mater ; 112: 104015, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32861064

RESUMO

Shape memory and super elastic alloys are commonly used in biomedical and engineering areas, due to their higher elastic deformation characteristics and low elastic module when in martensitic state. For biomaterial applications, the alloy must exhibit adequate corrosion resistance and biocompatibility, especially in chloride environments. The addition of ternary elements in NiTi alloys aim to improve the mechanical properties. Addition of Co increases the elastic limit and reduce the transformation temperature while Cr additions increase the yield strength. However, it was demonstrated that this modification can affect the corrosion resistance of the raw materials. This study aims to assess the corrosion and strain induced corrosion resistance of NiTi alloys modified by Co and Cr additions in the presence of 0.9% NaCl solution. Ternary alloys were compared to NiTi binary alloys, when unstrained and strained within the elastic regime where martensitic transformation is induced. Electrochemical impedance spectroscopy (EIS) and anodic polarization tests were performed on both conditions. Straining electrode corrosion tests were performed under constant electrochemical potential being the electrochemical response registered. Tests using wire samples as straining working electrodes permitted the assessment of the correlation between deformation and the anodic current of the alloys immersed in 0.9% NaCl solution. It was concluded that, despite the mechanical benefits provided by the addition of ternary elements, these additions increased the susceptibility to localized corrosion and the pitting corrosion susceptibility enhanced by stress and corresponding strain.


Assuntos
Ligas , Solução Salina , Materiais Biocompatíveis , Corrosão , Ligas Dentárias , Módulo de Elasticidade , Teste de Materiais , Propriedades de Superfície , Titânio
13.
Rev. cient. odontol ; 8(2): e018, mayo-ago. 2020. ilus, tab
Artigo em Espanhol | LIPECS, LILACS | ID: biblio-1119296

RESUMO

Antecedentes: Las limas rotatorias de níquel-titanio con tratamiento termomecánico se desarrollaron para permitir una mayor flexibilidad al instrumentar los conductos radiculares. Los instrumentos permitieron a los operadores tratar las curvaturas de los conductos con mayor facilidad. Los fabricantes están tratando de producir limas que funcionen de manera más eficiente y segura. Conocer las propiedades de las limas comercializadas es especialmente importante porque ayuda a elegir un sistema de lima apropiado. El objetivo de este estudio fue evaluar la flexibilidad de tres limas diferentes de níquel-titanio (NiTi) con tratamiento termomecánico en dos puntos diferentes. Materiales y métodos: Se midió la flexibilidad de tres limas NiTi con tratamiento termomecánico (ProTaper Gold, 2Shape y V-Taper Fanta Gold). Cada lima fue sujetada a 3 mm y 7 mm (n = 10/longitud/lima) y se utilizó una máquina de ensayo universal para doblarla a una fuerza máxima. Todos los datos fueron analizados estadísticamente por análisis de varianza de una vía y prueba de Tukey post hoc (p = 0,05) para determinar cualquier diferencia significativa. Resultados: Se halló diferencias estadísticamente significativas (p < 0,05). En general, V-Taper Fanta Gold fue la más rígida, ProTaper Gold mostró los mayores valores de fuerza y su deformación fue significativamente más flexible. Conclusión: Las limas ProTaper Gold mostraron una mayor flexibilidad en comparación con las otras limas estudiadas. (AU)


Background: Nickel-titanium rotary files with thermomechanical treatment were developed to allow greater flexibility when instrumenting the root canals. The instruments allowed operators to deal with duct curvatures more easily. Manufacturers are trying to produce files that work better efficiently and safely. Knowing the properties of marketed files is especially important in helping you choose an appropriate file system. The objective of this study was to evaluate the flexibility of three different nickel-titanium (NiTi) files with thermomechanical treatment at two different points along the file. Materials and methods: The flexibility of three NiTi files with thermomechanical treatment (Protaper Gold, 2Shape and V-Taper Fanta Gold) was measured. Each file was clamped at 3 mm and 7 mm (n = 10 / length / file) and a universal testing machine was used to bend the files to a maximum strength. All data were statistically analyzed by one-way analysis of variance and post-hoc Tukey test (P = 0.05) to determine any significant differences. Results: There were statistically significant differences (P <0.05). In general, V-Taper Fanta Gold was the most rigid, Protaper Gold showed the highest values of force and deformation was significantly more flexible. Conclusión: Protaper Gold files showed greater flexibility compared to the other files studied. (AU)


Assuntos
Titânio , Maleabilidade , Instrumentos Odontológicos , Ligas , Níquel
14.
Dental press j. orthod. (Impr.) ; 25(4): 51-58, July-Aug. 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1133680

RESUMO

ABSTRACT Objective: To investigate the effect of ZnO nanocoating on mechanical properties of NiTi orthodontic wires and antibacterial activity. Methods: 0.016 x 0.022-in NiTi orthodontic wires were coated with ZnO nanoparticles using an electrochemical deposition method with three electrodes system in 0.1M Zn(NO3)2. Mechanical properties and frictional resistance of the coated wires were investigated using an universal testing machine. Antibacterial effect of ZnO coating was also investigated. Results: A stable adhered ZnO nanocoating on NiTi wires was obtained. The coated wires have a significant antibacterial activity against S. aureus, S. pyogens and E. coli, and a reduction of frictional forces by 34%. Conclusion: ZnO nanocoating may improve the antibacterial effects of NiTi wires and reduce the frictional resistance. Coating may be implanted in orthodontic practice for faster and safer treatment.


RESUMO Objetivos: Avaliar o efeito do nanorrevestimento de óxido de zinco (ZnO) sobre as propriedades mecânicas e propriedades antibacterianas de fios ortodônticos de NiTi. Métodos: Fios 0,016" x 0,022" de NiTi foram revestidos com nanopartículas de ZnO por meio de um método de deposição eletroquímica com um sistema de três eletrodos a 0,1M Zn(NO3)2. Uma máquina universal de testes foi utilizada para avaliar as propriedades mecânicas e a resistência friccional dos fios revestidos. Além disso, também foram analisadas as propriedades antibacterianas do revestimento de ZnO. Resultados: Obteve-se uma aderência estável das nanopartículas de ZnO sobre os fios NiTi. Os fios revestidos apresentaram atividade antibacteriana significativa contra S. aureus, S. pyogens e E. coli, e apresentaram uma redução de 34% na força de atrito. Conclusão: O revestimento com nanopartículas de óxido de zinco pode melhorar as propriedades antibacterianas e reduzir a resistência friccional dos fios de NiTi. Assim, o revestimento dos fios pode ser utilizado na Ortodontia visando tratamentos mais rápidos e seguros.


Assuntos
Óxido de Zinco/farmacologia , Fios Ortodônticos , Staphylococcus aureus , Propriedades de Superfície , Titânio/farmacologia , Zinco , Teste de Materiais , Ligas Dentárias , Escherichia coli , Antibacterianos/farmacologia , Níquel
15.
Restor Dent Endod ; 45(2): e25, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32483542

RESUMO

OBJECTIVES: This systematic review evaluated the influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium (NiTi) instruments. MATERIALS AND METHODS: A systematic search without restrictions was conducted in the following electronic databases: PubMed, Scopus, Web of Science, ScienceDirect, Cochrane, and Open Grey. The hand search was also performed in the main endodontic journals. The eligible studies were submitted to the methodological assessment and data extraction. RESULTS: From 203 abstracts, a total of 10 articles matched the eligible criteria. After reading the full articles, 2 were excluded because of the absence of the heat-treated instruments in the experimental design and 3 due to the lack of a control group using heat-treated instruments without autoclave sterilization. From the 5 included studies, 1 presented a low risk of bias, 3 presented moderate and 1 high risk. It was observed heterogeneous findings in the included studies, with autoclave sterilization cycles increasing, decreasing or not affecting the cyclic fatigue life of heat-treated NiTi instruments. However, the retrieved studies evaluating the cyclic fatigue resistance of endodontic instruments presented different protocols and assessing outcomes, this variability makes the findings less comparable within and also between groups and preclude the establishment of an unbiased scientific evidence base. CONCLUSIONS: Considering the little scientific evidence and considerable risk of bias, it is still possible to conclude that autoclave sterilization procedures appear to influence the cyclic fatigue resistance of heat-treated NiTi instruments.

16.
Iran Endod J ; 15(3): 124-139, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-36703804

RESUMO

Introduction: Irregularities and defects on NiTi endodontic instruments originating from the manufacturing process can lead to the structural collapse and fracture of these instruments during treatment. To assess the cause of instrument wear and fracture, as well as increasing fracture incidence, destructive and non-destructive methods have been used for the analysis of surfaces and internal structures of new and used NiTi instruments. The aim of this systematic review was to undertake a detailed analysis of the methods used to evaluate the surface and internal microstructure of endodontic instruments. Methods and Materials: The scientific literature was comprehensively and systematically searched in the MEDLINE (PubMed), Web of Science, Cochrane Library, Scopus, and LILACS/BBO databases for studies published up to June 9, 2019. The eligibility criteria was based on the PICO (Patient, Intervention, Comparison, and Outcome) strategy with the question "What is the best method for structural analysis of endodontic files?" Two aspects were considered for inclusion in this study: (i) endodontic instruments and (ii) methods for structural analysis of NiTi instruments. . The systematic review was performed according to the PRISMA statement. Results: Based on the inclusion criteria, 94 articles were selected. The results showed that although specific methods have been used for qualitative and/or quantitative structural analysis of NiTi instruments, no study addressed both the surface and internal structure of the instruments at the same time. According to this review, the need to compare the methodologies used in the selected articles has been identified; however, each type of method used has its own limitation on the analysis of both the surface and the internal structure of the instruments. Conclusions: The comparison between the different types of methodologies used in the studies revealed the reliability and the limitations of the methods employed for structural analysis of endodontic instruments; thus assisting us in determining their validity.

17.
Belo Horizonte; s.n; 2020. 83 p. ilus, tab.
Tese em Português | BBO - Odontologia, LILACS | ID: biblio-1253965

RESUMO

As características geométricas e técnicas de fabricação das limas endodônticas afetam o desempenho clínico e sua resistência à fratura, flexibilidade e outras propriedades. Um parâmetro muito explorado na Endodontia é a utilização de tratamentos térmicos, que promovem um aumento na resistência à fadiga e flexibilidade destes materiais. Neste estudo pretendeu-se avaliar o efeito de diferentes processos de tratamento térmico/usinagem nas propriedades físicas, flexibilidade, resistência torcional e à fadiga flexural dos instrumentos Prodesign Logic (PDL), verificando se a sequência de processamento dos instrumentos levaria a comportamentos mecânicos diferentes. Este sistema é fabricado a partir de um método inovador que envolve a realização do tratamento térmico para obtenção de memória de forma no fio NiTi anteriormente à usinagem. A hipótese nula a ser testada é que o momento de aplicação dos procedimentos de tratamento térmico e usinagem não afetariam as propriedades físicas e mecânicas de instrumentos endodônticos de NiTi. Para grupos de comparação, foram utilizados protótipos de instrumentos com as mesmas características geométricas e dimensionais, sendo um grupo de instrumentos sem tratamento térmico aplicado (SEP) e outro com o tratamento térmico realizado de forma convencional, após a usinagem do instrumento (HTP). Foram realizadas caracterização física e microestrutural com ensaios de calorimetria exploratória diferencial (DSC) e testes de difratometria de Raios-X (DRX), além de ensaios mecânicos divididos em testes de torção, dobramento em 45 e resistência à fadiga flexural. Os resultados mostraram que macroscopicamente não houve nenhuma alteração importante nas características dos três grupos de instrumentos, exceto mudanças de cor devido a diferentes sequências de processamento. Os resultados de DSC mostraram que à temperatura ambiente a liga é principalmente austenítica no grupo SEP e que após o tratamento térmico realizado nos grupos PDL e HTP, houve uma mudança nas temperaturas de transformação, com um aumento da temperatura de Af e predominância da liga NiTi em fase R. Os resultados de XDR confirmaram os achados do DSC. As diferenças nos parâmetros medidos entre diferentes tipos de instrumentos nos ensaios de resistência torcional, dobramento a 45º e fadiga flexural foi sempre considerada com um nível de significância de 95%. Os resultados para os ensaios de flexão mostraram que o grupo HTP mostrou-se o mais flexível, com os mais baixos valores de momento de dobramento, seguido por PDL e SEP. Nos resultados dos ensaios de torção foi possível observar que SEP apresentou valores mais altos de torque seguido por PDL e HTP (p<.05). Os ensaios de resistência à fadiga mostraram valores médios de NCF maiores para HTP, seguido por PDL e SEP. Entretanto, um pior comportamento do PDL só seria evidenciado clinicamente se os instrumentos fossem usados um número de vezes maior do que o recomendado pelo fabricante. Pode-se concluir que alterar o processo de fabricação dos instrumentos endodônticos, invertendo-se as etapas de usinagem e tratamento térmico, levou, de fato, a uma mudança no comportamento mecânico de instrumentos Prodesign Logic em relação aos prótótipos.


The geometric characteristics and manufacturing techniques of endodontic instruments affect clinical performance, fracture resistance, flexibility and other properties. A parameter widely explored in Endodontics is the use of heat treatments, which promote an increase in the resistance to fatigue and flexibility of these materials. This study aimed to evaluate the effect of different heat treatment / machining processes on the physical properties, flexibility, torsional strength and flexural fatigue of Prodesign Logic (PDL) instruments, verifying whether the processing sequence of the instruments would lead to different mechanical behaviors. This system is manufactured using an innovative method that involves performing thermal treatment to obtain shape memory in the NiTi wire prior to machining. The null hypothesis to be tested is that the moment of application of the heat treatment and machining procedures would not affect the physical and mechanical properties of NiTi endodontic instruments. For comparison groups, instrument prototypes with the same geometric and dimensional characteristics were used, being one group of instruments without thermal treatment applied (SEP) and another with thermal treatment carried out in a conventional manner, after machining the instrument (HTP). Physical and microstructural characterization were performed with differential scanning calorimetry (DSC) tests and X-ray diffractometry (XRD) tests, in addition to mechanical tests divided into torsion tests, 45° bending and resistance to flexural fatigue. The results showed that macroscopically there were no major change in the characteristics of the three groups of instruments, except for color changes due to different processing sequences. The DSC results showed that at room temperature the alloy is mainly austenitic in the SEP group and that after the heat treatment carried out in the PDL and HTP groups, there was a change in the transformation temperatures, with an increase in the Af temperature and predominance of the NiTi alloy in phase R. The XRD results confirmed the DSC findings. Differences in the parameters measured between different types of instruments in the tests of torsional resistance, bending at 45º and flexural fatigue were always considered with a significance level of 95%. The results for the flexibility tests showed that the HTP group proved to be the most flexible, with the lowest values, followed by PDL and SEP. In the results of the torsion tests it was possible to observe that SEP presented higher values of torque followed by PDL and HTP (p <.05). Fatigue resistance tests showed higher mean NCF values for HTP, followed by PDL and SEP. However, a worse behavior of the PDL would only be evidenced clinically if the instruments were used several times greater than that recommended by the manufacturer. It can be concluded that changing the manufacturing process of endodontic instruments, inverting the machining and heat treatment steps, led, in fact, to a change in the mechanical behavior of Prodesign Logic instruments in relation to the prototypes.


Assuntos
Calorimetria , Instrumentos Odontológicos , Endodontia/instrumentação , Resistência à Tração , Maleabilidade
18.
J Contemp Dent Pract ; 20(12): 1380-1383, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-32381836

RESUMO

AIM: The aim of this study was to evaluate the force-release behavior of closed coil nickel-titanium springs of three different commercial brands available on the market, as well those from different batches, tested over multiple distances, according to the number of deactivations. MATERIALS AND METHODS: For this in vitro analysis, closed coil nickel-titanium springs of the following numbers and brands: eight, 3 mm GAC® springs; eight, 3 mm springs from TP Orthodontics® and eight, 5 mm springs from MORELLI® were standardized at 200 gf force. Two batches of all three brands were tested and compared. All springs were evaluated on a test machine and extended to a distance of five times beyond their original length. The springs were extended, and the distances of force released were measured and marked at every 20% of the total spring length, during their deactivation, and the process was repeated five times for each spring. RESULTS: The intraclass correlation coefficients showed that the value of 200 gf indicated by the manufacturers was poorly reproduced. The springs did not change their force release after successive extensions. All springs presented higher deactivation force values as their stretching increased. CONCLUSION: All springs presented the greater release of force as their stretch was increased, but the GAC® brand springs presented a more uniform pattern. TP Orthodontics® springs exhibited an acceptable force release pattern, but MORELLI® springs proved to be far below expected strength. CLINICAL SIGNIFICANCE: As a clinical consideration of the study, the results obtained in the present research are relevant to the use of nickel-titanium closed springs with regard to the quantity of force released during the mechanics of space closure after extraction (main application of nickel-titanium closed springs), and to the pattern of forces released by springs in view of the real context of gradual closure of spaces after tooth extractions.


Assuntos
Níquel , Titânio , Ligas Dentárias , Análise do Estresse Dentário , Desenho de Aparelho Ortodôntico , Fios Ortodônticos
19.
Rev. Cient. CRO-RJ (Online) ; 3(2): 32-36, May-Aug. 2018.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1021859

RESUMO

Objective: to assess the accuracy of the nominal initial diameter of ProTaper Universal® finishing files and their respective gutta-percha cones. Method : ProTaper Universal® finishing files, F1, F2, F3, F4 and F5 and corresponding ProTaper cones were used (10 of each). A Profile Projector was used to evaluate the initial diameter of files and cones. All measurements were repeated twice and performed by a single trained operator. A descriptive analysis of the files' initial diameters was performed considering the tolerance limit established by the ADA number 101. According to this standard, the files F1, F2 and F3 have a tolerance limit of ± 0.025 mm and the files F4 and F5 ± 0.05 mm. The same tolerance limit was used to evaluate the cones. The initial diameters of the instruments and cones studied were compared with the nominal values given by the manufacturer through Student's T test (pd"0.05). Results: No finishing file group showed adequate accuracy (pd"0.05). Accuracy was verified only from the F5 ProTaper cone group (p> 0.05). It was verified that 30% (n=15) of the finishing files and 20% (n = 10) of the cones exceeded the tolerance limits. Conclusion : Accuracy was not observed for any file and it was identified only in the F5 ProTaper Universal® cone. Most files and cones were within the tolerance limits established by the ADA.


Objetivo: Analisar a acurácia do diâmetro inicial dos instrumentos de acabamento do sistema ProTaper Universal® e seus respectivos cones de guta-percha. Método: Foram utilizados instrumentos de acabamento do sistema ProTaper Universal® F1, F2, F3, F4 e F5 e cones de guta-percha ProTaper correspondentes (10 de cada). O projetor de perfil foi usado para avaliar o diâmetro inicial dos instrumentos e cones. Todas as medições foram feitas duas vezes por um único operador treinado. Uma análise descritiva do diâmetro inicial dos instrumentos foi realizada considerando o limite de tolerância proposto pela ADA número 101. De acordo com essa norma, os instrumentos F1, F2 e F3 tem um limite de tolerância de ± 0.025 mm e os instrumentos F4 e F5 ± 0.05 mm. O mesmo limite de tolerância foi utilizado para avaliar os cones. Os diâmetros iniciais dos instrumentos e cones estudados foram comparados com os valores nominais dados pelo fabricante através do teste T (pd"0.05). Resultados: Foi verificada acurácia somente do cone de guta-percha ProTaper do grupo F5 (p>0,05). Nenhum grupo de instrumento de acabamento apresentou acurácia (pd"0,05). Foi verificado que 30% (n=15) dos instrumentos de acabamento e 20% (n=10) dos cones excederam o limite de tolerância. Conclusão: Acurácia não foi verificada em nenhum instrumento ProTaper Universal® e somente o cone F5 apresentou acurácia. A maioria dos instrumentos e cones estavam dentro do limite de tolerância proposto pela ADA.


Assuntos
Endodontia , Tratamento do Canal Radicular , Precisão da Medição Dimensional , Guta-Percha
20.
Int Endod J ; 51(11): 1271-1278, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29637579

RESUMO

AIM: To evaluate the presence and propagation of defects and their effects on surfaces of nickel-titanium (NiTi) instruments using noncontact, three-dimensional optical profilometry, and to assess the accuracy of this method of investigation. METHODOLOGY: The flute surface areas of instruments from two commercial instrumentation systems, namely Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were assessed and compared before and after performing two instrumentation cycles in simulated root canals in clear resin blocks. All the analyses were conducted on areas measuring 211 × 211 µm, located 3 mm from the tips of the instruments. A quantitative analysis was conducted before and after the first and second instrumentation cycles, using the Sa (average roughness over the measurement field), Sq (root mean square roughness) and Sz (average height over the measurement field) amplitude parameters. All the data were submitted to statistical analysis at a 5% level of significance. RESULTS: There was a significant increase (P = 0.007) in wear in both groups, especially between baseline and the second instrumentation cycle, with significantly higher wear values being observed on WaveOne instruments (Sz median values = 33.68 and 2.89 µm, respectively, for WO and RP groups). A significant increase in surface roughness (P = 0.016 and P = 0.008, respectively, for Sa and Sq) was observed in both groups from the first to the second instrumentation cycle, mostly in WaveOne specimens. Qualitative analysis revealed a greater number of defects on the flute topography of all the instruments after use. CONCLUSIONS: More defects were identified in WaveOne Primary instruments compared to Reciproc R25, irrespective of the evaluation stage. The investigation method provided an accurate, repeatable and reproducible assessment of NiTi instruments at different time-points.


Assuntos
Níquel/química , Preparo de Canal Radicular/instrumentação , Tratamento do Canal Radicular/instrumentação , Titânio/química , Ligas Dentárias/química , Instrumentos Odontológicos , Cavidade Pulpar , Endodontia/instrumentação , Desenho de Equipamento , Falha de Equipamento , Humanos , Imageamento Tridimensional/métodos , Teste de Materiais , Reprodutibilidade dos Testes , Rotação , Propriedades de Superfície , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA