Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Arq. bras. med. vet. zootec. (Online) ; 75(4): 571-590, July-Aug. 2023. tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1447355

RESUMO

The present study aimed to evaluate and compare the palmar and plantar digital arteries of 10 horses and 10 mules through B-mode and spectral Doppler ultrasound. Likewise, compare the plantar arteries of the pelvic limbs with the palmar arteries of the thoracic limbs, in addition to verifying the differences of the digital arteries in the contralateral limbs (right and left) in horses and mules using B-mode and spectral Doppler ultrasonography. The evaluated parameters were the diameter and the intima-media thickness (IMT), resistivity index (RI), pulsatility index (PI), peak of systolic velocity (pSV), final diastolic velocity (fDV) and mean velocity (MV) of the lateral and medial palmar and plantar arteries digital in healthy horses and mules. The horses presented higher diameters values, IMT, pSV, fDV and MV in comparison to the mules. The variables RI and PI also presented differences between horses and mules. Also, both species showed higher values in the variables of B-mode and Doppler ultrasonography in the thoracic limbs. Differences were also detected in the comparison between the limb sides (right and left) in the two modalities. The B-Mode and spectral Doppler ultrasound techniques are viable tools to identify differences in the palmar and plantar digital arteries in healthy horses and mules, highlight the differences between the thoracic and pelvic limbs and their respective sides (right and left) as well.


O presente estudo teve como objetivo avaliar e comparar as artérias digitais palmares e plantares de 10 equinos e 10 muares, por meio de ultrassom modo B e Doppler espectral. Da mesma forma, buscou-se comparar as artérias plantares dos membros pélvicos com as artérias palmares dos membros torácicos, além de se verificarem as diferenças das artérias digitais nos membros contralaterais (direito e esquerdo) em equinos e mulas, por meio de ultrassonografia modo B e Doppler espectral. Os parâmetros avaliados foram o diâmetro e a espessura médio-intimal (EMI), o índice de resistividade (IR), o índice de pulsatilidade (IP), o pico de velocidade sistólica (pVS), a velocidade diastólica final (VDf) e a velocidade média (VM) das artérias palmares e plantares lateral e medial digitais em equinos e muares sadios. Os equinos apresentaram maiores valores de diâmetros, EMI, pVS, VDf e VM em comparação aos muares. As variáveis IR e IP também apresentaram diferenças entre equinos e muares. Cavalos e mulas apresentaram maiores valores nas variáveis de ultrassonografia modo B e Doppler nos membros torácicos. Também foram detectadas diferenças na comparação entre os lados dos membros (direito e esquerdo) nas duas modalidades. As técnicas de ultrassom modo-B e Doppler espectral são ferramentas viáveis para identificar diferenças nas artérias digitais palmares e plantares em equinos e muares saudáveis, bem como para destacar as diferenças entre os membros torácicos e pélvicos e seus respectivos lados (direito e esquerdo).


Assuntos
Animais , Artérias , Ultrassonografia Doppler/veterinária , Cavalos , Locomoção
2.
Pesqui. vet. bras ; 43: e07212, 2023. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1507030

RESUMO

Mammary neoplasia represents the most frequently diagnosed type of neoplasia in bitches. Although surgical removal is the procedure of choice for therapeutic management, chemotherapy protocols appear as important allies and adjuvants. Despite the great advances that have occurred in the field of cancer therapy, the systemic repercussions of these drugs still impose important limitations on their use. In this sense, the development of increasingly targeted therapeutic protocols and preventive monitoring of patients represent important strategies to avoid possible complications - among them, Acute Kidney Injury (AKI). Routinely, ultrasound evaluation is used to identify morphological or metastatic variations in abdominal cavity organs. Acting complementary to the B-mode evaluation, Doppler mapping proves to be efficient in recognizing alterations in vascular hemodynamics. Therefore, the objective of the present study was to evaluate the use of B-mode and Doppler ultrasound to identify renal morphological and hemodynamic alterations in bitches with mammary neoplasia submitted to adjuvant chemotherapy protocols that associate gemcitabine with carboplatin. Thirteen bitches were included, without distinction of breed and between seven and 13 years of age. The animals were evaluated ultrasonographically at two different times during three consecutive chemotherapy cycles: before (T0) and one and a half hours after each cycle (T1), for 42 days. No morphological changes were observed in B-mode throughout the chemotherapy protocol. However, the Doppler velocimetry indices demonstrated statistical differences before (T0) and after (T1) the administration of the drugs. It was concluded that Doppler ultrasound could be used as a complementary method for monitoring the renal response of patients exposed to nephrotoxic drugs and potentially causing renal injury.


As neoplasias mamárias representam o tipo de neoplasma mais frequentemente diagnosticado em fêmeas da espécie canina. Embora a remoção cirúrgica seja o procedimento de eleição para a conduta terapêutica, os protocolos quimioterápicos aparecem como importantes aliados e adjuvantes. Apesar dos grandes avanços ocorridos na área da terapia oncológica, as repercussões sistêmicas destes fármacos ainda impõem importantes limitações ao seu uso. Neste sentido, o desenvolvimento de protocolos terapêuticos cada vez mais direcionados e o monitoramento preventivo dos pacientes representam estratégias importantes para evitar possíveis complicações - dentre elas, a injúria renal aguda (IRA). Rotineiramente, a avaliação ultrassonográfica é utilizada para identificação de variações morfológicas ou metastáticas em órgãos da cavidade abdominal. Atuando de forma complementar à avaliação em modo-B, o mapeamento Doppler mostra-se eficiente no reconhecimento de alterações na hemodinâmica vascular. Portanto, o objetivo do presente estudo foi avaliar a utilização da ultrassonografia modo-B e Doppler como método para identificação de alterações morfológicas e hemodinâmicas renais em cadelas com neoplasias mamárias submetidas a protocolos quimioterápicos adjuvantes que associam a gencitabina à carboplatina. Foram incluídas 13 fêmeas caninas, sem distinção quanto a raça e com idades entre sete e 13 anos. Os animais foram avaliados ultrassonograficamente em dois momentos distintos durante três ciclos quimioterápicos consecutivos: antes (T0) e uma hora e meia após a realização de cada ciclo (T1), totalizando 42 dias. Não foram observadas alterações morfológicas em modo-B ao longo do protocolo quimioterápico. Entretanto, os índices dopplervelocimétricos demonstraram diferenças estatísticas antes (T0) e após (T1) a administração dos fármacos. Concluiu-se que a ultrassonografia Doppler pode ser utilizada como método complementar para o monitoramento da resposta renal de pacientes expostos a fármacos nefrotóxicos e potencialmente causadores de injúrias renais.


Assuntos
Animais , Feminino , Cães , Neoplasias Mamárias Animais/complicações , Quimioterapia Adjuvante/efeitos adversos , Quimioterapia Adjuvante/veterinária , Doenças do Cão , Injúria Renal Aguda/veterinária , Injúria Renal Aguda/diagnóstico por imagem , Carboplatina , Ultrassonografia Doppler/veterinária , Gencitabina
3.
Pesqui. vet. bras ; Pesqui. vet. bras;41: e06655, 2021. tab, graf
Artigo em Inglês | VETINDEX, LILACS | ID: biblio-1287514

RESUMO

The aim of this study was to verify the applicability and accuracy of B-mode ultrasonography in detecting malignancy in dog cutaneous neoplasms. Forty-two neoplasms (12 benign and 30 malignant) of mesenchymal, round cells, epithelial and melanocytic origins from 24 dogs of different breeds and ages were included. The ultrasound evaluation was performed with a linear multi-frequency transducer (7.0 to 12MHz), with frequency dependent on the mass dimension. Ultrasonographic characteristics of echogenicity (hypo/hyperechogenic), echotexture (homogeneous/heterogeneous), regularity, invasiveness in adjacent tissues were classified. Dimensions were also measured to calculate the depth/width ratio. Neoplasms were classified as malignant or benign after cytological and/or histopathological analysis and the results were associated with ultrasound characteristics. There was a significant association (P<0.05) between malignancy and echogenicity, echotexture and invasiveness in adjacent tissues, so that 84.6% of hypoechogenic neoplasms, 76.9% of heterogeneous masses and 88.2% of invasive neoplasms were classified as malignant. However, for all these associations, moderate predictive values were obtained, which may be due to the small experimental number included in this study. Therefore, although it has been observed that hypoechogenic, heterogeneous and invasive neoplasms were more prone to malignancy, these findings should be used with caution until new studies are developed with a greater number and variety of cutaneous neoplasms in dogs.(AU)


O objetivo deste estudo foi verificar a aplicabilidade e acurácia da ultrassonografia modo-B na detecção de malignidade em neoplasmas cutâneos de cães. Foram incluídos 42 neoplasmas (12 benignos e 30 malignos) de origens mesenquimal, células redondas, epitelial e melanocítica provenientes de 24 cães de diferentes raças e idades. O exame ultrassonográfico foi realizado com transdutor linear multifrequencial (7.0 a 12MHz), com frequência dependente da dimensão da massa. Foram classificadas características ultrassonográficas de ecogenicidade (hipo/hiperecogênicos), ecotextura (homogêneos/heterogêneos), regularidade, invasividade em tecidos adjacentes. As dimensões foram mensuradas para cálculo da razão profundidade/largura. Os neoplasmas foram classificados como malignos ou benignos após análise cito e/ou histopatológica e os resultados foram associados com as características ultrassonográficas. Verificou-se associação significativa (P<0.05) entre malignidade e ecogenicidade, ecotextura e invasividade em tecidos adjacentes, de forma que 84.6% dos neoplasmas hipoecogênicos, 76.9% das massas heterogêneas e 88.2% dos neoplasmas invasivos foram classificados como malignos. Entretanto, para todas essas associações, foram obtidos valores preditivos moderados, que podem ser decorrentes do baixo número experimental incluso neste estudo. Sendo assim, embora tenha sido observado que os neoplasmas hipoecogênicos, heterogêneos e invasivos tiveram maior propensão à malignidade, esses achados devem ser utilizados com cautela até novos trabalhos sejam desenvolvidos com maior número e variedade de neoplasmas cutâneos de cães.(AU)


Assuntos
Animais , Cães , Morbidade , Ultrassonografia , Dente Canino , Neoplasias
4.
Pesqui. vet. bras ; Pesqui. vet. bras;412021.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1487651

RESUMO

ABSTRACT: The aim of this study was to verify the applicability and accuracy of B-mode ultrasonography in detecting malignancy in dog cutaneous neoplasms. Forty-two neoplasms (12 benign and 30 malignant) of mesenchymal, round cells, epithelial and melanocytic origins from 24 dogs of different breeds and ages were included. The ultrasound evaluation was performed with a linear multi-frequency transducer (7.0 to 12MHz), with frequency dependent on the mass dimension. Ultrasonographic characteristics of echogenicity (hypo/hyperechogenic), echotexture (homogeneous/heterogeneous), regularity, invasiveness in adjacent tissues were classified. Dimensions were also measured to calculate the depth/width ratio. Neoplasms were classified as malignant or benign after cytological and/or histopathological analysis and the results were associated with ultrasound characteristics. There was a significant association (P 0.05) between malignancy and echogenicity, echotexture and invasiveness in adjacent tissues, so that 84.6% of hypoechogenic neoplasms, 76.9% of heterogeneous masses and 88.2% of invasive neoplasms were classified as malignant. However, for all these associations, moderate predictive values were obtained, which may be due to the small experimental number included in this study. Therefore, although it has been observed that hypoechogenic, heterogeneous and invasive neoplasms were more prone to malignancy, these findings should be used with caution until new studies are developed with a greater number and variety of cutaneous neoplasms in dogs.


RESUMO: O objetivo deste estudo foi verificar a aplicabilidade e acurácia da ultrassonografia modo-B na detecção de malignidade em neoplasmas cutâneos de cães. Foram incluídos 42 neoplasmas (12 benignos e 30 malignos) de origens mesenquimal, células redondas, epitelial e melanocítica provenientes de 24 cães de diferentes raças e idades. O exame ultrassonográfico foi realizado com transdutor linear multifrequencial (7.0 a 12MHz), com frequência dependente da dimensão da massa. Foram classificadas características ultrassonográficas de ecogenicidade (hipo/hiperecogênicos), ecotextura (homogêneos/heterogêneos), regularidade, invasividade em tecidos adjacentes. As dimensões foram mensuradas para cálculo da razão profundidade/largura. Os neoplasmas foram classificados como malignos ou benignos após análise cito e/ou histopatológica e os resultados foram associados com as características ultrassonográficas. Verificou-se associação significativa (P 0.05) entre malignidade e ecogenicidade, ecotextura e invasividade em tecidos adjacentes, de forma que 84.6% dos neoplasmas hipoecogênicos, 76.9% das massas heterogêneas e 88.2% dos neoplasmas invasivos foram classificados como malignos. Entretanto, para todas essas associações, foram obtidos valores preditivos moderados, que podem ser decorrentes do baixo número experimental incluso neste estudo. Sendo assim, embora tenha sido observado que os neoplasmas hipoecogênicos, heterogêneos e invasivos tiveram maior propensão à malignidade, esses achados devem ser utilizados com cautela até novos trabalhos sejam desenvolvidos com maior número e variedade de neoplasmas cutâneos de cães.

5.
Pesqui. vet. bras ; Pesqui. vet. bras;412021.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1487655

RESUMO

ABSTRACT: The objective of this study was to verify the applicability of B-mode ultrasonography, ARFI elastography and CEUS in the diagnosis of chronic kidney disease and its Stages in dogs. 24 healthy dogs and 28 with CKD were included. In B-mode, the echogenicity, echotexture and cortico-medullary ratio of the kidneys were verified. By elastography, the shear-wave velocity of the cortical (SWVcort) and medullary (SWVmed) regions were determined and tissue deformity was evaluated. Wash-in, wash-out and peak enhancement (TPic) of the contrast in the renal parenchyma were calculated and homogeneity, presence of filling gaps and distinction of filling phases were evaluated by CEUS. Changes in echogenicity, echotexture and cortico-medullary ratio were observed only in sick patients. There was an increase in SWVcort in CKD, with a cutoff point >2.91m/s. Healthy kidneys were non-deformable and 25% had changes in gray scales. There was an increase in wash-in and TPic, changes in filling characteristics, filling failures and difficulty in distinguishing between the Stages in CEUS in CKD. It was found that dogs with CKD 2, 3 and 4 had greater SWVcort and wash-in values than CKD 1. Elastographic and CEUS changes were observed in dogs with CKD, demonstrating the applicability of ultrasonographic techniques in their diagnosis.


RESUMO: O objetivo deste estudo foi verificar a aplicabilidade da ultrassonografia modo-B, elastografia ARFI e CEUS no diagnóstico da doença renal crônica e seus estágios em cães. Foram incluídos 24 cães saudáveis e 28 com DRC. Pelo modo-B, verificou-se ecogenicidade, ecotextura e relação córtico-medular dos rins. Pela elastografia, foram determinadas as velocidades de cisalhamento das regiões cortical (SWVcort) e medular (SWVmed) e foi avaliada a deformidade tecidual. Calculou-se os temos de wash-in, wash-out e pico de intensidade (TPic) do parênquima renal e avaliou-se homogeneidade, presença de falhas e distinção das fases de preenchimento por contraste por meio de CEUS. Alterações em ecogenicidade, ecotextura e relação córtico-medular foram observadas somente em pacientes doentes. Houve aumento da SWVcort na DRC, com ponto de corte >2.91m/s. Rins saudáveis foram não-deformáveis e 25% apresentou alterações nas escalas de cinza. Houve aumento do wash-in e TPic, alterações nas características de preenchimento, falhas e dificuldade para distinguir as fases de preenchimento do contraste nos rins com DRC. Verificou-se que cães com DRC graus 2, 3 e 4 tiveram valores de SWVcort e wash-in maiores que cães com DRC grau 1. Foram obsrervadas alterações elastográfica e de CEUS em cães com DRC, demonstrando a aplicabilidade destas técnicas ultrassonográficas no seu diagnóstico.

6.
Pesqui. vet. bras ; Pesqui. vet. bras;41: e06785, 2021. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1250490

RESUMO

The objective of this study was to verify the applicability of B-mode ultrasonography, ARFI elastography and CEUS in the diagnosis of chronic kidney disease and its Stages in dogs. 24 healthy dogs and 28 with CKD were included. In B-mode, the echogenicity, echotexture and cortico-medullary ratio of the kidneys were verified. By elastography, the shear-wave velocity of the cortical (SWVcort) and medullary (SWVmed) regions were determined and tissue deformity was evaluated. Wash-in, wash-out and peak enhancement (TPic) of the contrast in the renal parenchyma were calculated and homogeneity, presence of filling gaps and distinction of filling phases were evaluated by CEUS. Changes in echogenicity, echotexture and cortico-medullary ratio were observed only in sick patients. There was an increase in SWVcort in CKD, with a cutoff point >2.91m/s. Healthy kidneys were non-deformable and 25% had changes in gray scales. There was an increase in wash-in and TPic, changes in filling characteristics, filling failures and difficulty in distinguishing between the Stages in CEUS in CKD. It was found that dogs with CKD 2, 3 and 4 had greater SWVcort and wash-in values than CKD 1. Elastographic and CEUS changes were observed in dogs with CKD, demonstrating the applicability of ultrasonographic techniques in their diagnosis.(AU)


O objetivo deste estudo foi verificar a aplicabilidade da ultrassonografia modo-B, elastografia ARFI e CEUS no diagnóstico da doença renal crônica e seus estágios em cães. Foram incluídos 24 cães saudáveis e 28 com DRC. Pelo modo-B, verificou-se ecogenicidade, ecotextura e relação córtico-medular dos rins. Pela elastografia, foram determinadas as velocidades de cisalhamento das regiões cortical (SWVcort) e medular (SWVmed) e foi avaliada a deformidade tecidual. Calculou-se os temos de wash-in, wash-out e pico de intensidade (TPic) do parênquima renal e avaliou-se homogeneidade, presença de falhas e distinção das fases de preenchimento por contraste por meio de CEUS. Alterações em ecogenicidade, ecotextura e relação córtico-medular foram observadas somente em pacientes doentes. Houve aumento da SWVcort na DRC, com ponto de corte >2.91m/s. Rins saudáveis foram não-deformáveis e 25% apresentou alterações nas escalas de cinza. Houve aumento do wash-in e TPic, alterações nas características de preenchimento, falhas e dificuldade para distinguir as fases de preenchimento do contraste nos rins com DRC. Verificou-se que cães com DRC graus 2, 3 e 4 tiveram valores de SWVcort e wash-in maiores que cães com DRC grau 1. Foram obsrervadas alterações elastográfica e de CEUS em cães com DRC, demonstrando a aplicabilidade destas técnicas ultrassonográficas no seu diagnóstico.(AU)


Assuntos
Animais , Cães , Anormalidades Congênitas , Ultrassonografia , Insuficiência Renal Crônica , Técnicas de Imagem por Elasticidade , Perfusão , Rim
7.
Pesqui. vet. bras ; 41: e06655, 2021. tab, graf
Artigo em Inglês | VETINDEX | ID: vti-33339

RESUMO

The aim of this study was to verify the applicability and accuracy of B-mode ultrasonography in detecting malignancy in dog cutaneous neoplasms. Forty-two neoplasms (12 benign and 30 malignant) of mesenchymal, round cells, epithelial and melanocytic origins from 24 dogs of different breeds and ages were included. The ultrasound evaluation was performed with a linear multi-frequency transducer (7.0 to 12MHz), with frequency dependent on the mass dimension. Ultrasonographic characteristics of echogenicity (hypo/hyperechogenic), echotexture (homogeneous/heterogeneous), regularity, invasiveness in adjacent tissues were classified. Dimensions were also measured to calculate the depth/width ratio. Neoplasms were classified as malignant or benign after cytological and/or histopathological analysis and the results were associated with ultrasound characteristics. There was a significant association (P<0.05) between malignancy and echogenicity, echotexture and invasiveness in adjacent tissues, so that 84.6% of hypoechogenic neoplasms, 76.9% of heterogeneous masses and 88.2% of invasive neoplasms were classified as malignant. However, for all these associations, moderate predictive values were obtained, which may be due to the small experimental number included in this study. Therefore, although it has been observed that hypoechogenic, heterogeneous and invasive neoplasms were more prone to malignancy, these findings should be used with caution until new studies are developed with a greater number and variety of cutaneous neoplasms in dogs.(AU)


O objetivo deste estudo foi verificar a aplicabilidade e acurácia da ultrassonografia modo-B na detecção de malignidade em neoplasmas cutâneos de cães. Foram incluídos 42 neoplasmas (12 benignos e 30 malignos) de origens mesenquimal, células redondas, epitelial e melanocítica provenientes de 24 cães de diferentes raças e idades. O exame ultrassonográfico foi realizado com transdutor linear multifrequencial (7.0 a 12MHz), com frequência dependente da dimensão da massa. Foram classificadas características ultrassonográficas de ecogenicidade (hipo/hiperecogênicos), ecotextura (homogêneos/heterogêneos), regularidade, invasividade em tecidos adjacentes. As dimensões foram mensuradas para cálculo da razão profundidade/largura. Os neoplasmas foram classificados como malignos ou benignos após análise cito e/ou histopatológica e os resultados foram associados com as características ultrassonográficas. Verificou-se associação significativa (P<0.05) entre malignidade e ecogenicidade, ecotextura e invasividade em tecidos adjacentes, de forma que 84.6% dos neoplasmas hipoecogênicos, 76.9% das massas heterogêneas e 88.2% dos neoplasmas invasivos foram classificados como malignos. Entretanto, para todas essas associações, foram obtidos valores preditivos moderados, que podem ser decorrentes do baixo número experimental incluso neste estudo. Sendo assim, embora tenha sido observado que os neoplasmas hipoecogênicos, heterogêneos e invasivos tiveram maior propensão à malignidade, esses achados devem ser utilizados com cautela até novos trabalhos sejam desenvolvidos com maior número e variedade de neoplasmas cutâneos de cães.(AU)


Assuntos
Animais , Cães , Morbidade , Ultrassonografia , Dente Canino , Neoplasias
8.
Pesqui. vet. bras ; 41: e06785, 2021. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-32489

RESUMO

The objective of this study was to verify the applicability of B-mode ultrasonography, ARFI elastography and CEUS in the diagnosis of chronic kidney disease and its Stages in dogs. 24 healthy dogs and 28 with CKD were included. In B-mode, the echogenicity, echotexture and cortico-medullary ratio of the kidneys were verified. By elastography, the shear-wave velocity of the cortical (SWVcort) and medullary (SWVmed) regions were determined and tissue deformity was evaluated. Wash-in, wash-out and peak enhancement (TPic) of the contrast in the renal parenchyma were calculated and homogeneity, presence of filling gaps and distinction of filling phases were evaluated by CEUS. Changes in echogenicity, echotexture and cortico-medullary ratio were observed only in sick patients. There was an increase in SWVcort in CKD, with a cutoff point >2.91m/s. Healthy kidneys were non-deformable and 25% had changes in gray scales. There was an increase in wash-in and TPic, changes in filling characteristics, filling failures and difficulty in distinguishing between the Stages in CEUS in CKD. It was found that dogs with CKD 2, 3 and 4 had greater SWVcort and wash-in values than CKD 1. Elastographic and CEUS changes were observed in dogs with CKD, demonstrating the applicability of ultrasonographic techniques in their diagnosis.(AU)


O objetivo deste estudo foi verificar a aplicabilidade da ultrassonografia modo-B, elastografia ARFI e CEUS no diagnóstico da doença renal crônica e seus estágios em cães. Foram incluídos 24 cães saudáveis e 28 com DRC. Pelo modo-B, verificou-se ecogenicidade, ecotextura e relação córtico-medular dos rins. Pela elastografia, foram determinadas as velocidades de cisalhamento das regiões cortical (SWVcort) e medular (SWVmed) e foi avaliada a deformidade tecidual. Calculou-se os temos de wash-in, wash-out e pico de intensidade (TPic) do parênquima renal e avaliou-se homogeneidade, presença de falhas e distinção das fases de preenchimento por contraste por meio de CEUS. Alterações em ecogenicidade, ecotextura e relação córtico-medular foram observadas somente em pacientes doentes. Houve aumento da SWVcort na DRC, com ponto de corte >2.91m/s. Rins saudáveis foram não-deformáveis e 25% apresentou alterações nas escalas de cinza. Houve aumento do wash-in e TPic, alterações nas características de preenchimento, falhas e dificuldade para distinguir as fases de preenchimento do contraste nos rins com DRC. Verificou-se que cães com DRC graus 2, 3 e 4 tiveram valores de SWVcort e wash-in maiores que cães com DRC grau 1. Foram obsrervadas alterações elastográfica e de CEUS em cães com DRC, demonstrando a aplicabilidade destas técnicas ultrassonográficas no seu diagnóstico.(AU)


Assuntos
Animais , Cães , Anormalidades Congênitas , Ultrassonografia , Insuficiência Renal Crônica , Técnicas de Imagem por Elasticidade , Perfusão , Rim
9.
R. bras. Reprod. Anim. ; 44(3): 95-99, jul.-set. 2020.
Artigo em Inglês | VETINDEX | ID: vti-761990

RESUMO

Puerpério é o período após a finalização do parto e acontece em escala logarítmica decrescente, especialmente durante a primeira semana após o parto, quando o útero passa por marcado remodelamento durante sua involução. No entanto, não estão totalmente elucidados os mecanismos hormonais, celulares e moleculares que regulam esse processo. Considerando a necessidade de estabelecer métodos diagnósticos precoces para a avaliação das mudanças no puerpério em ovelhas e a escassez no número de estudos sobre involução uterina, o monitoramento desse período é essencial para evitar declínio na eficiência reprodutiva, sendo que o intervalo de partos está diretamente relacionado à velocidade da involução uterina e ao retorno à atividade reprodutiva das fêmeas. Para isso, o entendimento do processo de recuperação do trato reprodutivo no pós-parto dessa espécie é de grande importância para o sucesso do sistema de produção em ovinos. Neste trabalho, revisamos o período puerperal, os mecanismos subjacentes à reprodução normal dos ovinos e a ultrassonografia para avaliar esse período na ovelha como modelo experimental ou para aplicação em Medicina Veterinária.(AU)


Puerperium is the period after the completion of delivery and occurs on a decreasing logarithmic scale, especially during the first week after delivery, when uterus undergoes marked remodeling. However, hormonal, cellular, and molecular mechanisms that regulate this process are not fully understood. Considering the need to establish early diagnostic methods to evaluate changes during sheeps puerperium and the scarce number of studies on uterine involution, monitoring this period is essential to avoid declining in reproductive efficiency, as calving interval is directly related to the speed of uterine involution and the return to female reproductive activity. Therefore, understanding the postpartum reproductive tract recovery process of this species is of great importance for the success of sheep production systems. We review the puerperal period, the mechanisms underlying the normal reproduction of sheep and ultrasonography to evaluate this period as an experimental model or for application in Veterinary Medicine.(AU)


Assuntos
Animais , Feminino , Ovinos , Ultrassonografia/veterinária , Período Pós-Parto , Técnicas Reprodutivas
10.
Rev. bras. reprod. anim ; 44(3): 95-99, jul.-set. 2020.
Artigo em Inglês | VETINDEX | ID: biblio-1492621

RESUMO

Puerpério é o período após a finalização do parto e acontece em escala logarítmica decrescente, especialmente durante a primeira semana após o parto, quando o útero passa por marcado remodelamento durante sua involução. No entanto, não estão totalmente elucidados os mecanismos hormonais, celulares e moleculares que regulam esse processo. Considerando a necessidade de estabelecer métodos diagnósticos precoces para a avaliação das mudanças no puerpério em ovelhas e a escassez no número de estudos sobre involução uterina, o monitoramento desse período é essencial para evitar declínio na eficiência reprodutiva, sendo que o intervalo de partos está diretamente relacionado à velocidade da involução uterina e ao retorno à atividade reprodutiva das fêmeas. Para isso, o entendimento do processo de recuperação do trato reprodutivo no pós-parto dessa espécie é de grande importância para o sucesso do sistema de produção em ovinos. Neste trabalho, revisamos o período puerperal, os mecanismos subjacentes à reprodução normal dos ovinos e a ultrassonografia para avaliar esse período na ovelha como modelo experimental ou para aplicação em Medicina Veterinária.


Puerperium is the period after the completion of delivery and occurs on a decreasing logarithmic scale, especially during the first week after delivery, when uterus undergoes marked remodeling. However, hormonal, cellular, and molecular mechanisms that regulate this process are not fully understood. Considering the need to establish early diagnostic methods to evaluate changes during sheep’s puerperium and the scarce number of studies on uterine involution, monitoring this period is essential to avoid declining in reproductive efficiency, as calving interval is directly related to the speed of uterine involution and the return to female reproductive activity. Therefore, understanding the postpartum reproductive tract recovery process of this species is of great importance for the success of sheep production systems. We review the puerperal period, the mechanisms underlying the normal reproduction of sheep and ultrasonography to evaluate this period as an experimental model or for application in Veterinary Medicine.


Assuntos
Feminino , Animais , Ovinos , Período Pós-Parto , Técnicas Reprodutivas , Ultrassonografia/veterinária
11.
Pesqui. vet. bras ; Pesqui. vet. bras;39(8): 663-667, Aug. 2019. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1040733

RESUMO

The gray scale histogram (GSH) makes it possible to measure the amount and distribution of gray shade frequencies, providing quantitative information on both echogenicity and echotexture of tissues. There is a need to diminish the subjectivity of the ultrasound images of the nuchal ligament (NL). This work proposes to evaluate the NL by ultrasound B-mode GSH images in different ages of Quarter horses. It used 15 healthy Quarter horses, which were classified by age into three different groups: "baby" (1), "sobreano" (2) and "adult" (3). The animals were submitted to chemical restraint for the ultrasound examination. Subsequently, the GSH tool was used in each image for statistical analysis. There was a significant difference between Mean and Mode between groups. Group 1 differed significantly when compared to Group 2 and 3. Group 2 presented superior echogenicity to Group 1 and 3. The height of the NL did not vary considerably between groups. GSH indicated that the echogenicity of NL in Quarter horses varies with age.(AU)


O histograma em escala de cinza (HEC) possibilita a mensuração da quantidade e distribuição da frequência de tonalidades de cinza, fornecendo informações quantitativas, tanto sobre a ecogenicidade quanto a ecotextura dos tecidos. Havendo a necessidade de diminuir a subjetividade das imagens ultrassonográficas do ligamento nucal (LN), esse trabalho propôs avaliar o LN por imagens ultrassonográficas modo-B pelo HEC em diferentes idades de cavalos da raça Quarto de Milha. Utilizou 15 cavalos da raça Quarto de Milha saudáveis os quais foram classificados por idade em três grupos diferentes: "baby" (1), "sobreano" (2) e "adulto" (3). Os animais foram submetidos a contenção química para a realização do exame ultrassonográfico. Posteriormente, a ferramenta HEC foi empregada em cada imagem para análise estatística. Houve diferença significativa entre as variáveis "Mean" e "Mode" entre os grupos. O Grupo 1 diferenciou significativamente quando comparado ao Grupo 2 e 3. O Grupo 2 apresentou ecogenicidade superior ao Grupo 1 e 3. Quanto à altura do LN não teve variação considerável entre os grupos. O HEC indicou que a ecogenicidade do LN em cavalos Quarto de Milha varia conforme a idade.(AU)


Assuntos
Animais , Vértebras Cervicais/diagnóstico por imagem , Ultrassonografia/veterinária , Cavalos
12.
Pesqui. vet. bras ; 39(8): 663-667, Aug. 2019. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-25185

RESUMO

The gray scale histogram (GSH) makes it possible to measure the amount and distribution of gray shade frequencies, providing quantitative information on both echogenicity and echotexture of tissues. There is a need to diminish the subjectivity of the ultrasound images of the nuchal ligament (NL). This work proposes to evaluate the NL by ultrasound B-mode GSH images in different ages of Quarter horses. It used 15 healthy Quarter horses, which were classified by age into three different groups: "baby" (1), "sobreano" (2) and "adult" (3). The animals were submitted to chemical restraint for the ultrasound examination. Subsequently, the GSH tool was used in each image for statistical analysis. There was a significant difference between Mean and Mode between groups. Group 1 differed significantly when compared to Group 2 and 3. Group 2 presented superior echogenicity to Group 1 and 3. The height of the NL did not vary considerably between groups. GSH indicated that the echogenicity of NL in Quarter horses varies with age.(AU)


O histograma em escala de cinza (HEC) possibilita a mensuração da quantidade e distribuição da frequência de tonalidades de cinza, fornecendo informações quantitativas, tanto sobre a ecogenicidade quanto a ecotextura dos tecidos. Havendo a necessidade de diminuir a subjetividade das imagens ultrassonográficas do ligamento nucal (LN), esse trabalho propôs avaliar o LN por imagens ultrassonográficas modo-B pelo HEC em diferentes idades de cavalos da raça Quarto de Milha. Utilizou 15 cavalos da raça Quarto de Milha saudáveis os quais foram classificados por idade em três grupos diferentes: "baby" (1), "sobreano" (2) e "adulto" (3). Os animais foram submetidos a contenção química para a realização do exame ultrassonográfico. Posteriormente, a ferramenta HEC foi empregada em cada imagem para análise estatística. Houve diferença significativa entre as variáveis "Mean" e "Mode" entre os grupos. O Grupo 1 diferenciou significativamente quando comparado ao Grupo 2 e 3. O Grupo 2 apresentou ecogenicidade superior ao Grupo 1 e 3. Quanto à altura do LN não teve variação considerável entre os grupos. O HEC indicou que a ecogenicidade do LN em cavalos Quarto de Milha varia conforme a idade.(AU)


Assuntos
Animais , Vértebras Cervicais/diagnóstico por imagem , Ultrassonografia/veterinária , Cavalos
13.
Pesqui. vet. bras ; 39(1): 75-84, jan. 2019. tab, ilus
Artigo em Inglês | VETINDEX | ID: vti-22371

RESUMO

As age increases, changes in cardiovascular anatomy and physiology occur, even in the absence of disease. Thus, studies of vessel hemodynamics are considered primordial to detect any cardiovascular changes. The objective of this study has been to describe the parameters of B-mode and spectral Doppler ultrasonography in the evaluation of the common carotid arteries of 11 equine and 11 mules, and correlate with age, body mass and neck circumferences. The diameters, intima - media thickness (IMT), resistivity index (RI), pulsatility index (PI), systolic velocity (SV), diastolic velocity (DV), maximum velocity (MV), vascular flow index (VFI), body mass, age, circumference and neck length. Ultrasonographic variables were evaluated in three different region called cranial, middle and caudal. Equine females presented higher values regarding the body mass, age and neck length, as compared to the neck circumferences of the animals, those of the mules were superior. The age of the mules had a positive correlation with the body mass, diameter and neck circumferences, it has a negative correlation between age and vessel diameters. The body mass of the mules had a positive correlation with age and vessel diameters, and with vessel diameters and neck circumferences in equine females. The RI and PI variables had a positive correlation with body mass for mules, and with age for equine females. The DV had a negative correlation with body mass for both equine and mule females. Regarding the variables MV and VFI, age correlated negatively for mules, while it was not significant for equine females. It found a difference between equine females and mules in the correlations performed, with body mass, age, neck circumferences and between B-mode and Doppler ultrasonography variables.(AU)


Com o aumento da idade ocorrem alterações na anatomia e fisiologia cardiovascular, mesmo na ausência de doenças. Assim, os estudos da hemodinâmica dos vasos são considerados primordiais para detectar quaisquer alterações cardiovasculares. Esse trabalho tem como objetivo descrever as variáveis de ultrassonografia modo-B e Doppler espectral na avaliação das artérias carótidas comuns de 11 fêmeas equinas e 11 muares, e correlacionar com idade, massa corpórea e circunferências dos pescoços. Para tais procedimentos foram avaliados os diâmetros, espessura da camada íntima média (EIM), índice de resistividade (IR), índice de pulsatilidade (IP), velocidade sistólica (VS), velocidade diastólica (VD), velocidade máxima (VM), índice de vascularização de fluxo (IVF), massa corpórea, idade, circunferências e comprimentos dos pescoços. As variáveis ultrassonográficas foram avaliadas em três regiões diferentes denominados de crania médio e caudal. As fêmeas equinas apresentaram valores maiores referente ao massa corpórea, idade e comprimento dos pescoços, já em relação às circunferências dos pescoços dos animais, as dos muares foram superiores. A idade dos muares possuiu correlação positiva com a massa corpórea, diâmetro e com as circunferências dos pescoços, com as fêmeas equinas, possui correlação negativa entre idade e os diâmetros dos vasos. A massa corpórea dos muares teve correlação positiva com idade e diâmetros dos vasos, já às fêmeas equinas com diâmetros dos vasos e as circunferências dos pescoços. As variáveis IR e IP tiveram correlação positiva com a massa corpórea para os muares, e com idade para fêmeas equinas. O VD teve correlação negativa com a massa corpórea tanto para as fêmeas equinas quanto nos muares. Já as variáveis VM e IVF, a idade correlacionou negativamente para os muares, enquanto não foi significativo para as fêmeas equinas. Averiguou diferença entre fêmeas equinas e muares nas correlações realizadas, com a massa corpórea, idade, circunferências dos pescoços e entre as variáveis da ultrassonografia modo-B e Doppler.(AU)


Assuntos
Animais , Artérias Carótidas/anatomia & histologia , Artérias Carótidas/fisiologia , Artérias Carótidas/diagnóstico por imagem , Equidae/anatomia & histologia , Equidae/fisiologia , Ultrassonografia/veterinária , Ultrassonografia Doppler/veterinária
14.
Pesqui. vet. bras ; Pesqui. vet. bras;39(1): 75-84, Jan. 2019. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-990231

RESUMO

As age increases, changes in cardiovascular anatomy and physiology occur, even in the absence of disease. Thus, studies of vessel hemodynamics are considered primordial to detect any cardiovascular changes. The objective of this study has been to describe the parameters of B-mode and spectral Doppler ultrasonography in the evaluation of the common carotid arteries of 11 equine and 11 mules, and correlate with age, body mass and neck circumferences. The diameters, intima - media thickness (IMT), resistivity index (RI), pulsatility index (PI), systolic velocity (SV), diastolic velocity (DV), maximum velocity (MV), vascular flow index (VFI), body mass, age, circumference and neck length. Ultrasonographic variables were evaluated in three different region called cranial, middle and caudal. Equine females presented higher values regarding the body mass, age and neck length, as compared to the neck circumferences of the animals, those of the mules were superior. The age of the mules had a positive correlation with the body mass, diameter and neck circumferences, it has a negative correlation between age and vessel diameters. The body mass of the mules had a positive correlation with age and vessel diameters, and with vessel diameters and neck circumferences in equine females. The RI and PI variables had a positive correlation with body mass for mules, and with age for equine females. The DV had a negative correlation with body mass for both equine and mule females. Regarding the variables MV and VFI, age correlated negatively for mules, while it was not significant for equine females. It found a difference between equine females and mules in the correlations performed, with body mass, age, neck circumferences and between B-mode and Doppler ultrasonography variables.(AU)


Com o aumento da idade ocorrem alterações na anatomia e fisiologia cardiovascular, mesmo na ausência de doenças. Assim, os estudos da hemodinâmica dos vasos são considerados primordiais para detectar quaisquer alterações cardiovasculares. Esse trabalho tem como objetivo descrever as variáveis de ultrassonografia modo-B e Doppler espectral na avaliação das artérias carótidas comuns de 11 fêmeas equinas e 11 muares, e correlacionar com idade, massa corpórea e circunferências dos pescoços. Para tais procedimentos foram avaliados os diâmetros, espessura da camada íntima média (EIM), índice de resistividade (IR), índice de pulsatilidade (IP), velocidade sistólica (VS), velocidade diastólica (VD), velocidade máxima (VM), índice de vascularização de fluxo (IVF), massa corpórea, idade, circunferências e comprimentos dos pescoços. As variáveis ultrassonográficas foram avaliadas em três regiões diferentes denominados de crania médio e caudal. As fêmeas equinas apresentaram valores maiores referente ao massa corpórea, idade e comprimento dos pescoços, já em relação às circunferências dos pescoços dos animais, as dos muares foram superiores. A idade dos muares possuiu correlação positiva com a massa corpórea, diâmetro e com as circunferências dos pescoços, com as fêmeas equinas, possui correlação negativa entre idade e os diâmetros dos vasos. A massa corpórea dos muares teve correlação positiva com idade e diâmetros dos vasos, já às fêmeas equinas com diâmetros dos vasos e as circunferências dos pescoços. As variáveis IR e IP tiveram correlação positiva com a massa corpórea para os muares, e com idade para fêmeas equinas. O VD teve correlação negativa com a massa corpórea tanto para as fêmeas equinas quanto nos muares. Já as variáveis VM e IVF, a idade correlacionou negativamente para os muares, enquanto não foi significativo para as fêmeas equinas. Averiguou diferença entre fêmeas equinas e muares nas correlações realizadas, com a massa corpórea, idade, circunferências dos pescoços e entre as variáveis da ultrassonografia modo-B e Doppler.(AU)


Assuntos
Animais , Artérias Carótidas/anatomia & histologia , Artérias Carótidas/fisiologia , Artérias Carótidas/diagnóstico por imagem , Equidae/anatomia & histologia , Equidae/fisiologia , Ultrassonografia/veterinária , Ultrassonografia Doppler/veterinária
15.
Rev. bras. reprod. anim ; 43(2): 137-146, abr.-jun. 2019. ilus, graf
Artigo em Português | VETINDEX | ID: biblio-1492562

RESUMO

A ultrassonografia (USG) é uma técnica de imagem em tempo real e pouco invasiva. Na produção de ovinos e caprinos, a USG vem sendo utilizada como uma ferramenta auxiliar no manejo reprodutivo, assim como no diagnóstico clínico-reprodutivo de doenças ginecológicas, obstétricas e andrológicas. Por meio da USG é possível a realização de exames em série para monitorar a progressão de uma anormalidade, resposta ao tratamento ou a funcionalidade e morfologia do órgão. Assim, por meio da USG são fornecidas informações substanciais ao profissional do campo e da pesquisa auxiliando na definição de prognósticos, tratamentos, descarte zootécnico e, ainda, na aquisição de reprodutores e matrizes sem distúrbios reprodutivos adquiridos ou congênitos.


Ultrasonography (USG) is a less invasive, real-time imaging modality. In the sheep and goat farming, USG has been used as an auxiliary tool in the reproductive management, as well as in the clinical-reproductive diagnosis of gynecological, obstetric and andrological disorders. Through the USG, it is possible to perform successive evaluations to monitor the progression of an abnormality, response to treatment or organ function and morphology. Therefore, through USG are provide substantial information to the practical and research veterinarian and assists in the definition of prognostics, treatments, culling and on the acquisition of breeding males and females without acquired or congenital reproductive disorders.


Assuntos
Animais , Cisto Folicular/diagnóstico , Cisto Folicular/veterinária , Ovinos/anormalidades , Ruminantes/anormalidades , Ultrassonografia Doppler/veterinária
16.
R. bras. Reprod. Anim. ; 43(2): 137-146, abr.-jun. 2019. ilus, graf
Artigo em Português | VETINDEX | ID: vti-21852

RESUMO

A ultrassonografia (USG) é uma técnica de imagem em tempo real e pouco invasiva. Na produção de ovinos e caprinos, a USG vem sendo utilizada como uma ferramenta auxiliar no manejo reprodutivo, assim como no diagnóstico clínico-reprodutivo de doenças ginecológicas, obstétricas e andrológicas. Por meio da USG é possível a realização de exames em série para monitorar a progressão de uma anormalidade, resposta ao tratamento ou a funcionalidade e morfologia do órgão. Assim, por meio da USG são fornecidas informações substanciais ao profissional do campo e da pesquisa auxiliando na definição de prognósticos, tratamentos, descarte zootécnico e, ainda, na aquisição de reprodutores e matrizes sem distúrbios reprodutivos adquiridos ou congênitos.(AU)


Ultrasonography (USG) is a less invasive, real-time imaging modality. In the sheep and goat farming, USG has been used as an auxiliary tool in the reproductive management, as well as in the clinical-reproductive diagnosis of gynecological, obstetric and andrological disorders. Through the USG, it is possible to perform successive evaluations to monitor the progression of an abnormality, response to treatment or organ function and morphology. Therefore, through USG are provide substantial information to the practical and research veterinarian and assists in the definition of prognostics, treatments, culling and on the acquisition of breeding males and females without acquired or congenital reproductive disorders.(AU)


Assuntos
Animais , Ruminantes/anormalidades , Ultrassonografia Doppler/veterinária , Cisto Folicular/diagnóstico , Cisto Folicular/veterinária , Ovinos/anormalidades
17.
Pesqui. vet. bras ; 39(8)2019.
Artigo em Inglês | VETINDEX | ID: vti-744294

RESUMO

ABSTRACT: The gray scale histogram (GSH) makes it possible to measure the amount and distribution of gray shade frequencies, providing quantitative information on both echogenicity and echotexture of tissues. There is a need to diminish the subjectivity of the ultrasound images of the nuchal ligament (NL). This work proposes to evaluate the NL by ultrasound B-mode GSH images in different ages of Quarter horses. It used 15 healthy Quarter horses, which were classified by age into three different groups: baby (1), sobreano (2) and adult (3). The animals were submitted to chemical restraint for the ultrasound examination. Subsequently, the GSH tool was used in each image for statistical analysis. There was a significant difference between Mean and Mode between groups. Group 1 differed significantly when compared to Group 2 and 3. Group 2 presented superior echogenicity to Group 1 and 3. The height of the NL did not vary considerably between groups. GSH indicated that the echogenicity of NL in Quarter horses varies with age.


RESUMO: O histograma em escala de cinza (HEC) possibilita a mensuração da quantidade e distribuição da frequência de tonalidades de cinza, fornecendo informações quantitativas, tanto sobre a ecogenicidade quanto a ecotextura dos tecidos. Havendo a necessidade de diminuir a subjetividade das imagens ultrassonográficas do ligamento nucal (LN), esse trabalho propôs avaliar o LN por imagens ultrassonograficas modo-B pelo HEC em diferentes idades de cavalos da raça Quarto de Milha. Utilizou 15 cavalos da raça Quarto de Milha saudáveis os quais foram classificados por idade em três grupos diferentes: baby (1), sobreano (2) e adulto (3). Os animais foram submetidos a contenção química para a realização do exame ultrassonográfico. Posteriormente, a ferramenta HEC foi empregada em cada imagem para análise estatística. Houve diferença significativa entre as variáveis Mean e Mode entre os grupos. O Grupo 1 diferenciou significativamente quando comparado ao Grupo 2 e 3. O Grupo 2 apresentou ecogenicidade superior ao Grupo 1 e 3. Quanto à altura do LN não teve variação considerável entre os grupos. O HEC indicou que a ecogenicidade do LN em cavalos Quarto de Milha varia conforme a idade.

18.
Rev. MVZ Córdoba ; 23(1): 6552-6563, Jan.-Apr. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-957352

RESUMO

ABSTRACT This study describes the ultrasonographic techniques currently used in the evaluation of the canine pancreas. Ultrasonography was the first method to enable direct visualization of the pancreas in humans and it has been subsequently applied to animals. Currently, it is the method of choice for pancreatic evaluation and is essential as a diagnostic tool in the detection of abnormalities, especially tumors. Innovative equipment technology has led to the emergence of techniques complementary to B-mode ultrasound; such as Doppler, elastography, and contrast-enhanced ultrasonography, which have enabled more accurate diagnosis. Doppler provides information on vascular architecture and the hemodynamic aspect of blood vessels in multiple organs. ARFI elastography provides detailed images of the alterations detected by conventional examination (qualitative method) and assists in differentiating between benign and malignant processes (quantitative method). Microbubble contrast agents determine parameters related to homogeneous and heterogeneous filling of organs with microbubbles, mainly nodular areas, thus defining high and low intensity patterns.


RESUMEN Este estudio describe las técnicas ecográficas frecuentemente utilizadas para evaluar el pancreas del perro. La ecografía fue el primer método que permitió la visualización directa del páncreas en seres humanos y que luego se aplicó en animales. Es actualmente el método de elección para la evaluación del páncreas y es esencial como herramienta diagnóstica en la detección de anomalías, especialmente tumores. La tecnología innovadora de los equipos, llevó a la aparición de técnicas complementarias al modo B, tales como Doppler, elastografía, ecografía de contraste, que han permitido realizar diagnósticos más precisos. El Doppler proporciona información sobre la arquitectura vascular y aspectos hemodinámicos de los vasos sanguíneos en múltiples órganos. La elastografía ARFI ofrece imágenes detalladas de las alteraciones detectadas en exámenes convencionales (método cualitativo) y ayuda a diferenciar entre procesos benignos y malignos (método cuantitativo). Los agentes de contraste con microburbujas permiten determinar parámetros relacionados con el llenado homogéneo o heterogéneo de los órganos, principalmente áreas nodulares, definiendo, por tanto, patrones de alta o baja intensidad.

19.
Pesqui. vet. bras ; Pesqui. vet. bras;38(4): 785-793, abr. 2018. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-955376

RESUMO

Agoutis are small-sized wild animals whose body weight can reach up to 4kg, and are found throughout Brazil. They are considered important seed dispersers, especially for big trees and there are species that rely almost exclusively on these animals for their territorial distribution. The objective of the present study was B scan and Doppler ultrasound characterization of the abdominal organs of healthy agoutis reared in captivity. Fifteen agoutis, chemically restrained, were used from the Nucleus for Wild Animal Studies and Conservation (Núcleo de Estudos e Preservação de Animais Silvestres - NEPAS), CCA-UFPI, submitted to B scan and Doppler ultrasound examination. The urinary bladder wall was hyperechogenic, thin, smooth and regular throughout its anatomic path, with 0.09±0.03cm mean thickness. The kidneys showed fine and homogeneous echotexture, preserved global echogenicity, hyperechogenic in relation to the spleen and isoechogenic or discreetly hyperechogenic in relation to the liver. The spectral Doppler trace showed systolic and diastolic peaks, wide and thread-like, with low flow resistance and a continuous and full diastolic portion that decreased gradually during the diastole (75.83±1.42cm/s, for the right kidney and 80.43±1.22cm/s, for the left kidney). The right adrenal gland was 0.61-1.18cm long and 0.17-0.32cm in diameter, while the left adrenal gland was 0.62-1.16 long with 0.14-0.25cm diameter. The agouti spleen was filiform in shape, with pointed poles and 1.02±0.18cm in diameter. The agouti liver occupied all the abdominal cavity cranial space in direct contact with the diaphragm. The intrahepatic vascular flow allowed individualization of the portal vein (PV) and hepatic vein (HV). The portal veins were distinguished from the hepatic veins mainly by their wall echogenic pattern. The pancreas was 0.51±0.1 cm thick and the pancreatic duct measured 0.12±0.02cm. The stomach was placed to the left the spleen and to the right of the proximal intestine and the transversal colon and the walls were 0.16±0.05cm thick. The abdominal aorta was 0.43±0.04cm in diameter and showed 95.2±2.16cm/s vascular flow. This study characterized agouti organs and abdominal blood vessels by B scan and Doppler ultrasound, that permitted definition of the size, shape, position, echogenicity and echotexture of the anatomic constituents and established reference values for the vascular network and blood flow in the species.(AU)


As cutias são animais silvestres de pequeno porte, cujo peso corpóreo pode chegar até 4kg, e existem em todo território brasileiro. São considerados importantes dispersores de sementes, especialmente para árvores de grande porte, existindo espécies que dependem quase que exclusivamente destas para sua distribuição territorial. Este trabalho teve por objetivo a caracterização ultrassonográfica modo B e Doppler dos órgãos abdominais de cutias hígidas criadas em cativeiro. Foram utilizadas 15 cutias, contidas quimicamente, oriundas do Núcleo de Estudos e Preservação de Animais Silvestres - NEPAS, CCA-UFPI, submetidas a exame ultrassonográfico em modo B e Doppler. A parede da vesícula urinária presentou-se hiperecogênica, fina, lisa e regular em todo seu trajeto anatômico, com espessura média de 0,09±0,03cm. Os rins demonstraram ecotextura fina e homogênea, ecogenicidade global preservada, hipoecogênico em relação ao baço e isoecogênico ou discretamente hipoecogênico em relação ao fígado. O traçado em Doppler espectral mostrou pico sistólico e diastólico, amplo e afilado, exibindo baixa resistência de fluxo, com uma porção diastólica contínua e cheia, que diminui gradativamente no decorrer da diástole (75,83±1,42cm/s para o rim direito e 80,43±1,22 cm/s para o esquerdo. A adrenal direita apresentou uma variação de comprimento entre 0,61 a 1,18cm e diâmetro variando entre 0,17 a 0,32cm, enquanto a adrenal esquerda evidenciou comprimento de 0,62 a 1,16 e diâmetro de 0,14 a 0,25cm. O baço das cutias mostrou formato filiforme, com polos pontiagudos e diâmetro de 1,02±0,18cm. O fígado da cutia ocupa todo o espaço cranial da cavidade abdominal, em contato direto com o diafragma. O fluxo vascular intrahepático permitiu individualizar as veias porta (VP) e veias hepáticas (VH). As veias porta foram distinguidas, particularmente pelo padrão ecogênico de suas paredes, quando comparadas com as veias hepáticas. A espessura do pâncreas foi de 0,51±0,1cm e o ducto pancreático mediu 0,12±0,02cm. O estômago relaciona-se à esquerda com o baço e a direita com o duodeno proximal e colón transverso. Sua espessura de parede mensurada foi de 0,16±0,05cm. A aorta abdominal possui diâmetro de 0,43±0,04cm e fluxo vascular de 95,2±2,16cm/s. Este estudo caracterizou os órgãos e vasos sanguíneos abdominais de cutias, por meio de ultrassonografia modo B e Doppler, o que permitiu definir o tamanho, formato, posição, ecogenicidade, ecotextura dos constituintes anatômicos, além de estabelecer valores de referência para a rede vascular e fluxo sanguíneo na espécie.(AU)


Assuntos
Animais , Ultrassonografia/estatística & dados numéricos , Ultrassonografia/veterinária , Dasyproctidae/anatomia & histologia
20.
Pesqui. vet. bras ; 38(4): 785-793, abr. 2018. tab, graf, ilus
Artigo em Inglês | VETINDEX | ID: vti-19481

RESUMO

Agoutis are small-sized wild animals whose body weight can reach up to 4kg, and are found throughout Brazil. They are considered important seed dispersers, especially for big trees and there are species that rely almost exclusively on these animals for their territorial distribution. The objective of the present study was B scan and Doppler ultrasound characterization of the abdominal organs of healthy agoutis reared in captivity. Fifteen agoutis, chemically restrained, were used from the Nucleus for Wild Animal Studies and Conservation (Núcleo de Estudos e Preservação de Animais Silvestres - NEPAS), CCA-UFPI, submitted to B scan and Doppler ultrasound examination. The urinary bladder wall was hyperechogenic, thin, smooth and regular throughout its anatomic path, with 0.09±0.03cm mean thickness. The kidneys showed fine and homogeneous echotexture, preserved global echogenicity, hyperechogenic in relation to the spleen and isoechogenic or discreetly hyperechogenic in relation to the liver. The spectral Doppler trace showed systolic and diastolic peaks, wide and thread-like, with low flow resistance and a continuous and full diastolic portion that decreased gradually during the diastole (75.83±1.42cm/s, for the right kidney and 80.43±1.22cm/s, for the left kidney). The right adrenal gland was 0.61-1.18cm long and 0.17-0.32cm in diameter, while the left adrenal gland was 0.62-1.16 long with 0.14-0.25cm diameter. The agouti spleen was filiform in shape, with pointed poles and 1.02±0.18cm in diameter. The agouti liver occupied all the abdominal cavity cranial space in direct contact with the diaphragm. The intrahepatic vascular flow allowed individualization of the portal vein (PV) and hepatic vein (HV). The portal veins were distinguished from the hepatic veins mainly by their wall echogenic pattern. The pancreas was 0.51±0.1 cm thick and the pancreatic duct measured 0.12±0.02cm...(AU)


As cutias são animais silvestres de pequeno porte, cujo peso corpóreo pode chegar até 4kg, e existem em todo território brasileiro. São considerados importantes dispersores de sementes, especialmente para árvores de grande porte, existindo espécies que dependem quase que exclusivamente destas para sua distribuição territorial. Este trabalho teve por objetivo a caracterização ultrassonográfica modo B e Doppler dos órgãos abdominais de cutias hígidas criadas em cativeiro. Foram utilizadas 15 cutias, contidas quimicamente, oriundas do Núcleo de Estudos e Preservação de Animais Silvestres - NEPAS, CCA-UFPI, submetidas a exame ultrassonográfico em modo B e Doppler. A parede da vesícula urinária presentou-se hiperecogênica, fina, lisa e regular em todo seu trajeto anatômico, com espessura média de 0,09±0,03cm. Os rins demonstraram ecotextura fina e homogênea, ecogenicidade global preservada, hipoecogênico em relação ao baço e isoecogênico ou discretamente hipoecogênico em relação ao fígado. O traçado em Doppler espectral mostrou pico sistólico e diastólico, amplo e afilado, exibindo baixa resistência de fluxo, com uma porção diastólica contínua e cheia, que diminui gradativamente no decorrer da diástole (75,83±1,42cm/s para o rim direito e 80,43±1,22 cm/s para o esquerdo. A adrenal direita apresentou uma variação de comprimento entre 0,61 a 1,18cm e diâmetro variando entre 0,17 a 0,32cm, enquanto a adrenal esquerda evidenciou comprimento de 0,62 a 1,16 e diâmetro de 0,14 a 0,25cm. O baço das cutias mostrou formato filiforme, com polos pontiagudos e diâmetro de 1,02±0,18cm. O fígado da cutia ocupa todo o espaço cranial da cavidade abdominal, em contato direto com o diafragma. O fluxo vascular intrahepático permitiu individualizar as veias porta (VP) e veias hepáticas (VH). As veias porta foram distinguidas, particularmente pelo padrão ecogênico de suas paredes, quando comparadas com as veias hepáticas...(AU)


Assuntos
Animais , Ultrassonografia , Ultrassonografia/veterinária , Dasyproctidae/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA