1.
Dental press j. orthod. (Impr.) ; 29(1): e2423285, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1534313

RESUMO

ABSTRACT Objective: This study aimed to evaluate occlusion development after premature loss or extraction of deciduous anterior teeth, by means of a prospective cohort study. Methods: Fifteen infants and children aged 1 to 5 years old were longitudinally assessed (with loss or extraction of deciduous anterior teeth [n = 9], and without tooth losses [n = 6]). Photographs and dental casts at the baseline and after 24 months of follow-up were performed. Dental casts were scanned, and linear measurements were made on the digitalized models (missing tooth space, arch perimeter, arch length, arch width, intercanine length and intercanine width). The t-test was used for groups comparisons (α = 0.05). Results: Individuals' mean age at baseline was 2.93 (± 1.18) years. No statistically significant differences were observed in the missing tooth space in the group with tooth loss during the 24 months of follow-up (p > 0.05). Arch perimeter, arch length, arch width, intercanine length and intercanine width did not show differences between the groups (p > 0.05). Qualitative photographic evaluation revealed other changes in the dental arches and occlusion, such as exfoliation and eruption of deciduous teeth, eruption of permanent teeth, self-correction or establishment of malocclusion, among others. Conclusion: The results suggest that the premature loss of deciduous anterior teeth does not affect the perimeter, length and width of the dental arches; however, other alterations that lead to malocclusion could be established.


RESUMO Objetivo: Este estudo teve como objetivo avaliar o desenvolvimento da oclusão após perda prematura ou extração de dentes decíduos anteriores, por meio de um estudo de coorte prospectivo. Métodos: Quinze bebês e crianças de 1 a 5 anos foram avaliados longitudinalmente (com perda ou extração de dentes anteriores decíduos [n = 9] e sem perdas dentárias [n = 6]). Foram realizadas fotografias e modelos dentais no início e após 24 meses de acompanhamento. Os modelos dentários foram escaneados e medidas lineares foram feitas nos modelos digitalizados (espaço dentário perdido, perímetro da arcada, comprimento da arcada, largura da arcada, comprimento intercaninos e largura intercaninos). O teste t foi utilizado para comparações entre grupos (α = 0,05). Resultados: A média de idade dos indivíduos no início do estudo foi de 2,93 (± 1,18) anos. Não foram observadas diferenças estatisticamente significativas no espaço dentário perdido no grupo com perda dentária durante os 24 meses de acompanhamento (p > 0,05). O perímetro da arcada, comprimento da arcada, largura da arcada, comprimento intercaninos e largura intercaninos não apresentaram diferenças entre os grupos (p> 0,05). A avaliação fotográfica qualitativa revelou alterações nas arcadas dentárias e na oclusão, como: esfoliação e erupção de dentes decíduos, erupção de dentes permanentes, autocorreção ou estabelecimento de má oclusão, entre outras. Conclusão: Os resultados sugerem que a perda prematura de dentes anteriores decíduos não afeta o perímetro, comprimento e largura das arcadas dentárias; entretanto, outras alterações que levam à má oclusão poderiam ser estabelecidas.

2.
Rev. ABENO ; 23(1): 2064, mar. 2023. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-1524936

RESUMO

O objetivo deste relato de experiência foi integrar os componentes curriculares Escultura Dental e Prótese Parcial Removível por meio da confecção de macromodelos com nichos em dentes anteriores e posteriores a serem usados como material didático auxiliar.A metodologia teve abordagem descritiva. Foram confeccionados macromodelos em cera dos seguintes elementos dentários: caninos superiores e inferiores, pré-molar superior e molares superiores e inferiores. Em seguida, nichos foram preparados nos elementos,reproduzindo as características da etapa de Preparo de Boca Tipo II ou Protético. Macromodelos com as características individuais de nichos oclusais simples e duplo (interdental) em dentes posteriores foram obtidos, bem como com nichos em cíngulos, tanto confecionados por desgaste como por acréscimo. Diante do conhecimento da anatomia dental e a habilidade manual desenvolvidos na Escultura Dental, os macromodelos confeccionados permitiram uma melhor visualização das características morfológicas dos nichos,sendo considerado um recurso complementar no processo ensino-aprendizagem em Prótese Parcial Removível (AU).


El objetivo de este relato de experiencia fue integrar los componentes curriculares Escultura Dental y Prótesis Parcial Removible mediante la creación de macromodelos con nichos en dientes anteriores y posteriores para ser utilizados como material didáctico auxiliar. La metodología tuvo un enfoque descriptivo. Se realizaron macromodelos en cera de los siguientes dientes: caninos superiores e inferiores, premolares superiores y molares superiores e inferiores. A continuación, se prepararon nichos en los elementos, reproduciendo las características de la etapa de Preparación de la Boca Tipo II o Prótesis. Se obtuvieron macromodelos con las características individuales de nichos oclusales simples y dobles (interdentales) en dientes posteriores, así comonichos en cingulados, ambos creados por desgaste y adición. Dado el conocimiento de la anatomía dental y la habilidad manual desarrollada en la Escultura Dental, los macromodelos realizados permitieron una mejor visualización de las características morfológicas de los nichos, considerándose un recurso complementario en el proceso de enseñanza-aprendizaje en Prótesis Parcial Removible (AU).


The objective of this experience report was to integrate the curricular components of Dental Sculpture and Removable Partial Dentures through the creation of macromodels with rest seat in anterior and posterior teeth to be used as auxiliary teaching material. The methodology had a descriptive approach. Wax macromodels were made of the following teeth: upper and lower canines, upper premolar and upper and lower molars. Next, rest seats were prepared in the elements, reproducing the characteristics of the Type II or Prosthetic Mouth Preparation stage. Macromodels with the individual characteristics of single and double (interdental) occlusal rest seats in posterior teeth were obtained, as well as rest seats in cingulum, both created by wear and with composites. Given the knowledge of dental anatomy and the manual skill developed in Dental Sculpture, the macromodels made enabled better visualization of the morphological characteristics of the rest seats, being considered a complementary resource in the teaching-learning process in Removable Partial Prosthesis (AU).


Assuntos
Modelos Dentários , Prótese Parcial Removível , Educação em Odontologia , Moldagem de Cera para Incrustações
3.
J. health sci. (Londrina) ; 25(1): 02-09, 20230330.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1510041

RESUMO

Esse estudo propectivo teve como objetivo realizar a avaliação das alterações dentoalveolares em modelos digitais de pacientes cuja mordida aberta anterior foi tratada seguindo dois protocolos distintos: esporão lingual e mentoneira. A amostra foi composta por 41 pacientes (27 do sexo feminino e 14 do sexo masculino) com idades entre 7-10 anos (média de idade de 8.37 anos), dentição mista com diagnóstico de mordida aberta anterior (média de -3.43mm) e tratados ao longo de um ano. Os pacientes foram aleatoriamente dividiso em dois grupos de acordo com a terapia realizada: Grupo 1 (n=23) tratados com esporão lingual, e Grupo 2 (n=18) tratados com mentoneira pré-fabricada. Os modelos de gesso foram escaneados, gerando uma imagem tridimensionao em qual as medidas foram realizadas em 2 tempos distintos: T1 (imediatamente antes do tratamento) e T2 (um ano após o início do tratamento). Alteraçnoes transversais, comprimento e perímetro dos arcos dentários superior e inferior, trespasse horizontal e vertical, assim como inclinação dos incisivos centrais foram avaliadas. O Coeficiente de Correlação Interclasse (CCI) e o método Bland-Altman foram aplicados para verificar o erro intra examinador. Os resultados foram analisados através do Teste T pareado e independente adotando uma significância de 5%. Após um ano de tratamento, observou-se alerações estatisticamente significantes em todas as variáveis, exceto perímetro e comprimento dos arcos superio e inferior, inclinação do incisivo central superior e trespasse horizontal. As alterações enre os grupos (T2-T1) apresentaram resultados similares. Concluiu-se que ambos os protocolos apresentaram mudanças semelhantes na mordiada aberta anterior após um ano de tratamento.(AU)

4.
RGO (Porto Alegre) ; 71: e20230002, 2023. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1422498

RESUMO

ABSTRACT Context: Digital study models have become a safe and advantageous alternative for diagnosis and planning in dentistry. Despite the superior characteristics in comparison with traditional plaster models, professionals seem to resist the use of new technologies. Aims: To assess the level of knowledge and the use of digital models through a questionnaire applied to dental professionals. Methods: A questionnaire with 12 multiple-choice questions about plaster models, digital, and use of the 3Shape - 3D viewer software was answered by 76 orthodontists (42 women and 34 men; mean age =37.82 years (SD ± 7.60)) and 30 general dental surgeons (18 women and 12 men; mean age of 33.93 years (SD ± 8.45)) in Aracaju, Sergipe, Brazil. Data were tabulated in Excel spreadsheets and then analyzed using the SPSS statistical software version 20. An absolute analysis of frequency and percentage of responses was performed. Results: Most professionals reported using plaster models and claimed their low cost as justification for their use (P = 0.001). Aware of the benefits of digital models, professionals of both classes highlighted the facilitated storage and search for information as the main advantages, the cost and infrastructure as the main disadvantages. Regarding the use of the 3Shape - 3D viewer software, orthodontists showed better utilization of this resource than general dental surgeons (P = 0.0198). Conclusion: It verified that most professionals make use of plaster models. However, despite knowing the advantages of digital models, their cost is sees as a limiting factor for adherence to this technology.


RESUMO Contexto: Os modelos digitais de estudo têm se tornado uma alternativa segura e vantajosa para o diagnóstico e planejamento em odontologia. Apesar das características superiores em comparação aos modelos tradicionais de gesso, os profissionais parecem resistir ao uso de novas tecnologias. Objetivos: Avaliar o nível de conhecimento e a utilização de modelos digitais por meio de questionário aplicado a profissionais da área odontológica. Material e Métodos: Questionário com 12 questões de múltipla escolha sobre modelos de gesso, digitais e uso do software 3Shape - 3D viewer foi respondido por 76 ortodontistas (42 mulheres e 34 homens; idade média = 37,82 anos (DP = ± 7,60) ) e 30 cirurgiões-dentistas gerais (18 mulheres e 12 homens; média de idade de 33,93 anos (DP = ± 8,45)) em Aracaju, Sergipe, Brasil. Os dados foram tabulados em planilhas do Excel e posteriormente analisados no software estatístico SPSS versão 20. Foi realizada uma análise absoluta de frequência e percentual de respostas. Resultados: A maioria dos profissionais relatou utilizar modelos de gesso e alegou seu baixo custo como justificativa para seu uso (P = 0,001). Cientes dos benefícios dos modelos digitais, os profissionais de ambas as classes destacaram o armazenamento facilitado e a busca de informações como as principais vantagens, o custo e a infraestrutura como as principais desvantagens. Em relação à utilização do software 3Shape - 3D viewer, os ortodontistas apresentaram melhor aproveitamento desse recurso do que os cirurgiões-dentistas gerais (P = 0,0198). Conclusões: Verificou-se que a maioria dos profissionais faz uso de modelos de gesso. Porém, apesar de conhecer as vantagens dos modelos digitais, seu custo é visto como um fator limitante para a adesão a essa tecnologia.

5.
Natal; s.n; 25 fev. 2022. 36 p. tab, ilus, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1532963

RESUMO

O objetivo deste estudo laboratorial foi avaliar a acurácia dos modelos digitais obtidos por duas técnicas de escaneamento (escâner intraoral - Itero 5d Element® - e escâner de bancada -Straumann ®) de um modelo experimental (Nacional Ossos ®) da arcada superior confeccionada em poliuretano e do modelo de gesso obtido desta arcada. Os pontos A ­ 3mm acima do elemento 17; B ­ 3mm acima do elemento 14; C ­ 3mm acima do elemento 24; D ­ 3mm acima do elemento 27; E ­ cúspide mesiovestibular do elemento 16; F - ponto de contato mais incisal entre os elementos 11 e 21; G - Cúspide mesiovestibular do elemento 26 foram utilizados como referência para as medidas realizadas. As medidas foram realizadas em um software (Geomagic®) de simulação cirúrgica e analisadas quanto a validade e precisão das técnicas de escaneamento utilizadas em todos os grupos (1 a 5). O grupo 1 corresponde ao grupo padrão-ouro; o 2 ao grupo do escaneamento com escâner intraoral do modelo de poliuretano; o 3 ao escaneamento de bancada do modelo; o 4 ao escaneamento com escâner intraoral do modelo de gesso; e 5 ao escaneamento de bancada do modelo de gesso. Na análise da validação, todas as técnicas apresentaram-se válidas quando comparadas ao grupo controle com exceção da medida FG que apresentou diferenças estatisticamente significativas (p<0,05) entre os grupos 1 e 2. A precisão foi avaliada através do índice de correlação intraclasse (CCI) e todas as técnicas apresentaram-se altamente precisas com (CCI) próximo de 1. Desta forma, conclui-se que o escâner intraoral e o escâner de bancada utilizados neste estudo foram confiáveis quando comparados ao grupo controle e que os dois modelos de escâner utilizados se apresentaram com alta precisão (AU).


The objective of this experimental study was to evaluate the accuracy of digital models generated by two scanning techniques (intraoral scanner - Itero 5d Element® - and desktop scanner -Straumann ®) of an experimental model of the upper arch (Nacional Ossos ®) made of polyurethane and the plaster model obtained from this arch. Points A ­ 3mm above element 17; B ­ 3mm above element 14; C ­ 3mm above element 24; D ­ 3mm above element 27; E ­ mesiobuccal cusp of element 16; F - most incisal point of contact between elements 11 and 21; G - Mesiobuccal cusp of element 26 were used as a reference for the measurements performed. The measurements were performed in a surgical simulation software (Geomagic ®) and analyzed for the validity and precision of the scanning techniques used in all groups (1 to 5). Group 1 corresponds to the gold standard group; 2 to the scanning group with intraoral scanner of the polyurethane model; 3 to the desktop scan of the model; 4 to intraoral scanner scanning of the plaster model; and 5 to the desktop scan of the plaster model. In the validation analysis, all techniques showed to be valid compared to the control group, except the FG measure, which showed statistically significant differences (p<0.05) between groups 1 and 2. Precision was assessed using the intraclass correlation(ICC) index, and all techniques were highly accurate with an ICC close to 1. Thus, it is concluded that the intraoral scanner and the bench scanner used in this study were reliable compared to the control group and that the two scanner models used presented themselves with high precision (AU).


Assuntos
Imageamento Tridimensional/instrumentação , Modelos Dentários/tendências , Cirurgia Ortognática , Precisão da Medição Dimensional , Estatísticas não Paramétricas , Técnicas de Laboratório Clínico
6.
Belo Horizonte; s.n; 2022. 90 p. ilus.
Tese em Português | BBO - Odontologia | ID: biblio-1425469

RESUMO

O uso de alinhadores transparentes tem se tornado um fenômeno mundial na clínica ortodôntica e muitos esforços e recursos têm sido consumidos para que o resultado do tratamento seja o mais acurado possível. Em 2021 a Invisalgn® lançou protocolo G8 prometendo melhor previsibilidade no tratamento. É através da sobreposição de imagens que estes resultados podem ser avaliados. Na literatura, encontram-se relatos de diversos métodos e softwares que buscam confiabilidade para sobreposição de modelos tridimensionais (3D), entretanto não há consenso sobre estes métodos. Desta forma, os objetivos deste estudo foram: (1) Desenvolver novo método de sobreposição de modelos 3D com Autodesk Inventor®, (2) avaliar a reprodutibilidade do Autodesk Inventor® utilizando o sistema de coordenadas universais (UCS) associado a único ponto para sobreposição de modelos ortodônticos 3D da mandíbula e maxila, (3) avaliar a reprodutibilidade do Autodesk Inventor® na sobreposição de modelo ortodôntico 3D da maxila e mandíbula, (4) Comparar a acurácia do protocolo G8 através do resultado previsto pelo ClinCheck® com o resultado real obtido nos movimentos de intrusão e expansão dentária posterior. Para responder os objetivos 1, 2 e 3, foram selecionados 11 pares de modelos em STL (estereolitografia) de ambos os arcos exportados pelo software My Itero® e tratados com Invisalign® em dois tempos: início (T0) e refinamento (T1). As sobreposições foram realizadas utilizando os softwares Slicer® (versão 4.1) e Autodesk Inventor® usando como referência os planos dos 3 eixos cartesianos UCS (X, Y e Z) associado a um ponto na segunda ruga palatina na maxila e, na mandíbula, um ponto na linha muco gengival lingual. Após a sobreposição os movimentos de translação buco-lingual dos caninos, pré-molares e molares superiores e inferiores, intrusão, rotação dos caninos e incisivos mandibulares foram analisados por dois examinadores calibrados. Para responder o objetivo 4, a acurácia foi comparada nos movimentos alcançados e previstos pelo ClinCheck® entre três casos em que o protocolo G8 foi ativado e 8 casos em que não foi ativado para a expansão posterior maxila e mandíbula, intrusão de caninos e incisivos inferiores. Os resultados do objetivo 1, 2 e 3 foram coeficientes de correlação intraclasse (ICC) maior que 0,90 em todas as medidas, não foi observado erro sistemático avaliado pela fórmula de Dahlberg. Nos resultados do objetivo 4 não foram observadas diferenças estatísticas significativas entre os grupos. A acurácia no grupo G8 quando comparada ao grupo não G8 para expansão posterior na mandíbula e maxila aumentou 12.7% e 7,8% respectivamente, mas não houve diferenças estatísticas significante. Para o movimento de intrusão, a acurácia do grupo G8 foi 7,7% maior que a do grupo não G8 sem diferença estatística entre eles. Não foram observadas diferenças estatísticas significativas nos movimentos dos dentes dos grupos G8 e não G8. Concluiu-se que o método desenvolvido se mostrou reprodutível para sobreposição de modelos tridimensionais. O protocolo G8, quando ativado, não apresenta maior acurácia para o tratamento com Invisalign®.


The use of clear aligners has become a worldwide phenomenon in orthodontic practice and much effort and resources have been expended to ensure that the treatment outcome is as accurate as possible. In 2021 Invisalgn® released the G8 protocol promises better treatment predictability. It is through image superimposition that these results can be evaluated. In the literature, there are reports of various methods and software that seek reliability for superimposing three-dimensional (3D) models, but there is no consensus on these methods. Thus, the objectives of this study were: (1) Develop a new method for superimposing 3D models with Autodesk Inventor®, (2) evaluate the reproducibility of Autodesk Inventor® using the universal coordinate system (UCS) associated with a single point for superimposing 3D orthodontic models of the mandible and maxilla (3) Evaluate the reproducibility of Autodesk Inventor® in superimposing orthodontic 3D models of the maxilla and mandible, (4) Compare the accuracy of the G8 protocol through the result predicted by ClinCheck® with the actual result obtained in intrusion movements and posterior dental expansion. To answer the objectives 1, 2 and 3, 11 pairs of STL (Stereo- lithography) models of both arches exported by My Itero® software and treated with Invisalign® were selected at two times: initial (T0) and refinement (T1). The superpositions were performed using the Slicer® (version 4.1) and Autodesk Inventor® software using as reference the planes of the three Cartesian axes (X, Y and Z) associated with a point on the second palatal crease in the maxilla and, in the mandible, a point on the lingual mucous gingival line. After superimposition, the bucco-lingual translation movements of the canines, premolars and upper and lower molars, intrusion, rotation of the canines and mandibular incisors were analyzed by two calibrated examiners. To answer the objective 4, the accuracy was compared in the movements achieved and predicted by ClinCheck® between three cases in which the G8 protocol was activated and 8 cases in which it was not activated for maxillary and mandibular posterior expansion, canine and mandibular incisor intrusion. The results of objectives 1, 2 and 3 were intraclass correlation coefficients (ICC) greater than 0.90 in all measurements, no systematic error evaluated by the Dahlberg formula was observed. In the results of objective 4, no statistically significant differences were observed between the groups. The accuracy in the G8 group when compared to the non-G8 group for posterior expansion in the mandible and maxilla increased by 12.7% and 7.8% respectively but without statistically significant differences. For intrusion movement, the accuracy of the G8 group was 7.7% higher than the non G8 group with no statistical difference between groups. No statistically significant differences were observed in the tooth movements of the G8 and non-G8 groups. It was concluded that the developed method proved reproducible for three- dimensional model superimposition. The G8 protocol, when activated, does not present greater accuracy for treatment with Invisalign®


Assuntos
Aparelhos Ortodônticos Removíveis , Técnicas de Movimentação Dentária , Reprodutibilidade dos Testes , Imageamento Tridimensional , Modelos Dentários
7.
Ortho Sci., Orthod. sci. pract ; 15(59): 71-76, 2022. tab, ilus
Artigo em Português | BBO - Odontologia | ID: biblio-1401110

RESUMO

Resumo Objetivo: Esse estudo teve como objetivo comparar a acurácia de mensurações lineares realizadas, de acordo com o método de Moyers, em modelos de gesso pelo método manual com paquímetro em modelos digitais 3D digitalizados por scanner de mesa e em modelos digitais 3D obtidos por Tomografia Computadorizada Multislice com protocolo CTdBem. Método: Um único operador selecionou 90 modelos de gesso da arcada inferior para análise de dentição mista. Os métodos testados e o método manual foram comparados usando o teste-t pareado. Para avaliar o acordo entre os métodos, a correlação de Pearson foi utilizada. O gráfico de Bland-Altman foi construído para avaliar a diferença entre as medidas de cada amostra. Resultados: Não houve diferenças significativas entre as medidas do scanner e da Tomografia Computadorizada Multislice, quando comparadas com as medidas do método manual (p>0.05). Ambos os métodos digitais apresentaram correlação alta e significativa com o método manual com coeficientes de 0,98 e 0,97 para o scanner e a Tomografia Computadorizada Multislice, respectivamente (p<0.01). Conclusão: Os modelos digitais obtidos por scanner de mesa e por Tomografia Computadorizada Multislice com protocolo CTdBem produziram medidas lineares e com boa acurácia, compatíveis com as medidas manuais realizadas em modelo de gesso. (AU)


Abstract Aim: This study has aimed to compare the accuracy of linear measurements made, according to the Moyers method, on plaster casts by the manual method using a pachymeter in digital 3D models digitalized by a desktop scanner and in 3D digital models scanned by Multislice Computed Tomography using the CTdBem protocol. Method: A single operator has selected 90 plaster casts of the mandibular arch for analysis of mixed dentition. The methods tested and manual method were compared by using the paired t-test. To assess the agreement between the methods, Pearson's correlation was performed. The Bland-Altman plot was built to evaluate the difference among the measurements for each sample. Results: There were no significant differences between scanner and Multislice CT measurements when compared to the manual method measurements (p> 0.05). Both digital methods have had a high and significant correlation with the manual method with coefficients of 0.98 and 0.97 for the scanner and Multislice CT method, respectively (p<0.01). Conclusions: The digital models obtained by means of the desktop scanner and Multislice Computed Tomography by means of CTdBem protocol produced linear measurement and with good accuracy, compatible with the manual measurements made on plaster casts (AU)


Assuntos
Imageamento Tridimensional , Modelos Dentários , Dentição Mista , Tomografia Computadorizada Multidetectores
8.
Dental press j. orthod. (Impr.) ; 27(1): e2219388, 2022. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1364782

RESUMO

ABSTRACT Introduction: Currently, no method is considered effective for the evaluation of digital models in the Certification Examination of the Brazilian Board of Orthodontics (BBO), considering the parameters of the currently used manual method. Objective: Thus, the aim of this study is to verify the reliability of an evaluation method for digital models that could be used in the BBO exam, compared to the gold standard. Methods: Measurements were performed by five previously calibrated examiners. Samples of ten sets of plaster models of the final phase of orthodontic treatment were measured using a manual method (Objective Grading System, OGS). These models were digitized using a 3D scanner and exported to Geomagic Qualify software, in which the measurements were made with the proposed digital method. These measurements were repeated using five models, after fifteen days. The intra-examiner performance with this method was analyzed with a paired t-test, whereas the inter-examiner analysis was carried out with analysis of variance and Tukey's test. To compare the manual and digital methods, a paired t-test and Pearson's correlation analysis were performed. Results: A statistically significant difference was found. The results showed that, when compared to the manual method, the digital method was effective in measuring the OGS in four of the seven variables studied: Marginal Ridge, Overjet, Occlusal Contact, and Interproximal Contact. The variables Alignment, BL inclination, and Occlusal Relationship showed a great amount of dispersion in the findings. Conclusion: Further studies are needed to develop an adequate digital methodology that can be used for all OGS variables.


RESUMO Introdução: Ainda não há um método considerado eficaz para análise dos modelos digitais no exame do Board Brasileiro de Ortodontia (BBO), considerando-se os parâmetros do método manual atual. Objetivo: Assim, o presente estudo objetiva verificar a confiabilidade de um método de avaliação em modelos digitais para o exame do BBO, comparando com o padrão-ouro. Métodos: As medições foram realizadas por 5 examinadores, previamente calibrados. A amostra de 10 pares de modelos de gesso da fase final do tratamento ortodôntico foi medida no método manual (Sistema Objetivo de Avaliação, SOA). Os modelos foram digitalizados por meio de um scanner 3D e exportados para o software Geomagic Qualify, onde foram feitas as medidas no método digital proposto. As medidas foram refeitas em 5 modelos após 15 dias. A análise intraexaminador desse método foi realizada por meio do teste t pareado; já a interexaminadores, feita com ANOVA e teste de Tukey, sendo encontrada diferença estatisticamente significativa. Para a comparação dos métodos manual e digital, foram utilizados o teste t pareado e a correlação de Pearson. Resultados: Uma diferença estatisticamente significativa foi encontrada. Os resultados mostraram que, comparada ao método manual, a metodologia digital mostrou-se eficaz para medição do SOA em quatro das sete variáveis estudadas: Margem interproximal, Sobressaliência, Contato oclusal e Contato interproximal. As variáveis Alinhamento, Inclinação V-L e Relação oclusal mostraram muita dispersão nos achados. Conclusão: Mais estudos são necessários para o desenvolvimento de uma metodologia digital adequada em todas as variáveis do SOA.


Assuntos
Ortodontia , Software , Projetos Piloto , Reprodutibilidade dos Testes , Modelos Dentários
9.
Rio de Janeiro; s.n; 2021. 63 p. tab.
Tese em Português | BBO - Odontologia | ID: biblio-1401033

RESUMO

A tecnologia vem ganhando espaço de maneira acelerada em todas as áreas do conhecimento, não sendo diferente na Odontologia. Na Ortodontia, o correto planejamento exige a utilização de exames complementares, como radiografias, fotografias intra e extraorais, traçados cefalométricos e modelos das arcadas dentárias. Tradicionalmente, os modelos são confeccionados em gesso e obtidos através de uma moldagem com alginato de toda a arcada do paciente. Contudo, a substituição de modelos em gesso por modelos digitais é uma realidade na Odontologia contemporânea, especialmente por possuir vantagens como facilidade de acesso, armazenamento e transferência, e precisão da captura de imagens técnicas. Trata-se de um estudo observacional transversal, que avaliou a acurácia de mensurações lineares, realizadas por ortodontistas, em modelos digitais obtidos por meio de escaneamento direito e imagens de tomografia computadorizada de feixe cônico (TCFC). Alterações clínicas simuladas, com a presença de objetos metálicos, foram realizadas para verificar uma possível interferência nas mensurações e, além disso, foi testada a eficácia da ferramenta de redução de artefatos metálicos (RAM), presente no exame de TCFC. A amostra foi composta por 15 ortodontistas que atuaram como examinadores do estudo, sendo responsáveis pela realização das mensurações nos modelos. Dois crânios secos, com os dentes íntegros, foram utilizados para obtenção dos modelos digitais. Foram utilizados o teste t pareado, para a análise comparativa das mensurações entre examinadores e padrão-ouro, assim como para correlação intraclasse, e o Modelo de Equações de Estimativas Generalizada (Modelo GEE) para verificar se a experiência dos examinadores e uso rotineiro dos modelos digitais interferia na acurácia das mensurações. Os dados obtidos foram tabulados e analisados utilizando o programa SPSS, com o nível de significância 5%. Os ortodontistas apresentaram alta correlação intra-examinador para praticamente todas as variáveis testadas (média de 0,88), exceto nos parâmetros "distâncias intermolares" (média de 0,37) e "discrepância de Bolton" (média de 0,31). Quando as mensurações foram comparadas com o padrão-ouro, os valores encontrados pelos examinadores diferiram estatisticamente em todos os parâmetros testados, em pelo menos um dos modelos obtidos, porém essas diferenças não apresentaram relevância clínica. Nos quesitos tempo de experiência e uso rotineiro de modelos digitais, os grupos estudados não apresentaram diferenças na maioria dos parâmetros avaliados. Além disso, não foram encontradas diferenças nas mensurações realizadas em modelos com metal, com e sem a utilização da ferramenta RAM. Conclui-se que os ortodontistas são capazes de realizar mensurações acuradas em modelos digitais, independente da prática rotineira com essa tecnologia, e o tempo de experiência na especialidade favorece a realização de mensurações mais precisas. As alterações clínicas simuladas com a presença de objetos metálicos, não prejudicaram a análise acurada dos modelos. No entanto, a ferramenta RAM não facilitou a realização das mensurações nos modelos extraídos da TCFC que possuíam objetos metálicos. (AU)


Technology has been gaining ground in an accelerated way in all areas of knowledge, being no different in Dentistry. In Orthodontics, correct planning requires the use of complementary exams such as radiographs, intra and extraoral photographs, cephalometric tracings, and dental arch models. Traditionally, the models are made in plaster and escape through the molding with alginate of all the patient's arch. However, the replacement of plaster models by digital models is a reality in contemporary Dentistry, especially for having advantages such as ease of access, storage and transfer, and precision in capturing technical images. This is a cross-sectional observational study, which evaluated the accuracy of linear measurements performed by orthodontists, in digital models used through straight scanning and cone beam computed tomography (CBCT) images. Simulated clinical alterations, with the presence of metallic objects, were carried out to verify a possible interference in the measurements and, in addition, the metallic artifact reduction tool (MAR), present in the CBCT exam, was tested. The sample consisted of 15 orthodontists who acted as examiners for the study, being performed by carrying out measurements in the models. Two dry skulls, with intact teeth, were used to obtain the digital models. The paired t-test was used for a comparative analysis of measurements between examiners and the gold standard, as well as for intraclass correlation, and the Generalized Estimating Equation Model (GEE Model) to verify whether the experience of examinations and routine use of digital models interfered with the accuracy of the measurements. The data gathered were tabulated and the SPSS program used throughout with a 5% significance level. The independent orthodontists had high intra-examiner correlation for practically all variables tested (mean of 0.88), except for the parameters "intermolar distances" (mean of 0.37) and "Bolton discrepancy" (mean of 0.31). When the measurements were compared with the gold standard, the values found by the examiners differed statistically in all tested parameters, in at least one of the required models, but these differences did not parallel clinically. In terms of experience time (years) and routine use of digital models, the studied groups did not differ in most of the parameters adopted. Furthermore, no differences were found in the measurements performed on metal models, with and without the use of the MAR tool. It is concluded that orthodontists can perform accurate measurements on digital models, regardless of their routine practice with this technology, and the length of experience in the specialty favors the performance of more accurate measurements. The clinical changes simulated with the presence of metallic objects did not affect the accurate analysis of the models. However, a MAR tool did not facilitate the performance of measurements in models extracted from CBCT that had metallic objects. (AU)


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Precisão da Medição Dimensional , Modelos Anatômicos , Ortodontia , Modelos Dentários/tendências
10.
Dental press j. orthod. (Impr.) ; 26(3): e2119148, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1286208

RESUMO

ABSTRACT Objective: The objectives of the present study were to develop a method for longitudinally measuring tooth rotation, inclination and angulation on digital models, and to test the method validity and reliability. Methods: The initial and final planned models of 14 patients treated with Invisalign® (386 teeth) were exported from ClinCheck®. The rotation, inclination and angulation values were assessed for the incisors, canines, premolars and molars, in both models, using trigonometry. An application was developed in Python 2.7 to automate the measurements. The ∆planned (variation in the position between the initial and final planned models) was obtained for each tooth and each type of movement. To test the validity, the degree of agreement between the ∆planned and the values available in the Invisalign® Table of Movements was assessed using the Intraclass Correlation Coefficient (ICC) and Bland-Altman analysis. For intra and inter-rater reliabilities, the ∆planned was obtained again. Results: Excellent ICCs (> 0.9) and limits of agreement with narrow and clinically acceptable discrepancies were obtained for the rotation of all teeth (except maxillary canines, which had broader limits: -3.47 - 5.43) and for the inclination of premolars and molars. The inclination of anterior teeth and angulation of all teeth had ICCs and limits that were not indicative of great agreement. The reliability was high for the three movements (discrepancy <2°). Conclusions: The method developed is reliable and suitable for longitudinally measuring inclination (posterior teeth) and rotation (except maxillary canines). It has limited value for the other movements measurements.


RESUMO Objetivo: Os objetivos do presente estudo foram desenvolver um método para medir longitudinalmente a rotação, inclinação e angulação dentárias em modelos digitais, e testar sua validade e reprodutibilidade. Material e Métodos: Os modelos inicial e final planejado de 14 pacientes tratados com Invisalign® (386 dentes) foram exportados do ClinCheck®. Os valores de rotação, inclinação e angulação foram calculados para incisivos, caninos, pré-molares e molares, em ambos os modelos, por meio de trigonometria. Um aplicativo desenvolvido em Python 2.7 foi utilizado para automatização das medidas. O ∆planejado (variação na posição entre os modelos inicial e final planejado) foi obtido para os movimentos descritos, nos diferentes grupos de dentes. A validade do método foi verificada pelo grau de concordância entre o ∆planejado e os valores disponíveis na Tabela de Movimentos do Invisalign®, utilizando-se o Coeficiente de Correlação Intraclasse (ICC) e a análise de Bland-Altman. O ∆planejado foi novamente calculado para análise da reprodutibilidade intra e interexaminadores. Resultados: Excelentes ICCs (> 0,9) e limites de concordância com discrepâncias reduzidas e clinicamente aceitáveis foram obtidos para a rotação de todos os dentes (exceto os caninos superiores, que expressaram limites mais amplos: -3,47 - 5,43) e para a inclinação de pré-molares e molares. A inclinação dos dentes anteriores e a angulação de todos os dentes apresentaram ICCs e limites não representativos de boa concordância. A reprodutibilidade foi alta para os três movimentos (discrepância < 2°). Conclusões: O método desenvolvido é reprodutível e se mostrou adequado para mensuração longitudinal da inclinação de dentes posteriores e rotação de todos os dentes, exceto caninos superiores. Apresenta valor limitado para as demais mensurações.


Assuntos
Humanos , Técnicas de Movimentação Dentária , Dente Canino , Dente Pré-Molar , Reprodutibilidade dos Testes , Incisivo
11.
Acta odontol. latinoam ; Acta odontol. latinoam;33(3): 221-227, Dec. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1278208

RESUMO

ABSTRACT The aim of this study was to evaluate the precision and accuracy of molds made with four commercial brands of alginate scanned at different times using digital model analysis. Eighty molds of a standard Typodont were made using 4 types of alginate (CCC: Cavex Color Change; IA: Identic Alginate; HY5: Hydrogum 5 and JP: Jeltrate Plus). The molds were scanned at four times: immediately (T1), 24h (T2), 72h (T3) and 120h (T4) after molding. Measurements were taken in three dimensions: anteroposterior, transverse and vertical. Significant differences in dimensional changes were noted between the materials over time (p <0.05). Anteroposterior dimensional variation was noted between times, especially for IA and JP. For transverse and vertical variables, a difference was found between the groups, especially at 24 h, 72 h and 120 h. CCC presented significant dimensional shrinkage only at T120 (transverse). IA and JP presented larger dimensional distortions in the vertical measurements. The molding materials used were not dimensionally stable when evaluated after 120 hours of molding. However, such evidence suggests that alginates with longer storage time, such as Cavex Color Change, are more accurate than conventional alginates.


RESUMO O objetivo do presente estudo foi avaliar a precisao e acurácia por meio de análise de modelos digitais de moldes digitalizados obtidos com quatro marcas comerciais de alginato em diferentes tempos. Oitenta moldes de um Typodont padrao foram obtidos utilizando 4 tipos de alginato (CCC: Cavex Color Change; IA: Identic Alginate; HY5: Hydrogum 5 e JP: Jeltrate Plus). Os moldes foram escaneados em quatro tempos: mediatamente (T1), 24h (T2), 72h (T3) e 120h (T4) após a moldagem. As medidas foram feitas em très dimensoes: ântero-posterior, transversal e vertical. Diferenças significativas nas mudanças dimensionais foram observadas entre os materiais ao longo do tempo (p <0,05). Variação dimensional ântero-posterior foi observada entre os tempos, principalmente para IA e JP. Para as variáveis transversal e vertical houve diferenga entre os grupos, principalmente em 24h, 72h e 120h. CCC apresentou contração dimensional significativa apenas em T120 (transversal). IA e JP apresentaram maiores distorções dimensionais na vertical. Os materiais de moldagem utilizados nao foram dimensionalmente estáveis quando avaliados após 120 horas de moldagem. No entanto, tais evidencias sugerem que os alginatos com maior tempo de armazenamento, como Cavex Color Change, sao mais precisos do que os alginatos convencionais.


Assuntos
Humanos , Materiais para Moldagem Odontológica/química , Modelos Dentários , Alginatos/química , Teste de Materiais , Técnica de Moldagem Odontológica
12.
Acta odontol. latinoam ; Acta odontol. latinoam;33(1): 3-5, June 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1130725

RESUMO

ABSTRACT The aim of this study was to compare the accuracy and precision of 3D printers used to obtain models of fixed dental prostheses. A fixed dental prosthesis preparation was scanned and reproduced by four 3D printers: RapidShape P40, Asiga MAX, Varseo, and Photon. The impressions were scanned again, and the dataset was compared to the original dataset. Mean discrepancies (μm) were 52.97±20.48 (RapidShape P40), 68.27±43.53 (Asiga MAX), 62.22±56.21 (Varseo), and 80.03±28.67 (Photon). There was no difference (p=0.314) in accuracy; however, the precision differed (p=0.015) among the 3D printers. The printers had distinct precision but did not differ in accuracy.


RESUMO O objetivo desse trabalho foi comparar a acurácia e a precisão de impressoras 3D utilizadas para a obtenção de modelos para prótese fixa. Um preparo para prótese fixa foi escaneado e reproduzido por 4 impressoras 3D: RapidShape 3D, Asiga MAX, Varseo e Photon. As impressões foram novamente escaneadas, e o dataset escaneado foi comparado ao original. Os esca neamentos foram sobrepostos digitalmente e determinada a discrepância entre os modelos original e impresso. A discre pância média (μm) entre os modelos foi de foi 52,97±20,48 (RapidShape 3D), 68,27±43,53 (Asiga MAX), 62,22±56,21 (Varseo) e 80,03±28,67 (Photon). Não houve diferença (p=0,314) entre os valores médios, os quais representam a acurácia; entretanto, o desvio padrão dessas foi diferente (0,015), indicando diferença na precisão das impressoras 3D.


Assuntos
Humanos , Prótese Dentária , Modelos Dentários , Impressão Tridimensional/normas
13.
Dental press j. orthod. (Impr.) ; 24(1): 37e1-37e9, Jan.-Feb. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-989688

RESUMO

ABSTRACT Introduction: Palatal rugae complete its development during early intrauterine life, whereas dental malocclusions in permanent dentition establishes several years into the post-natal life. Objective: The objective of present study was to determine if there is an association between the palatal rugae pattern and Angle's classes of malocclusion. Methods: A cross-sectional study was conducted on pretreatment dental casts of 184 patients. The sample was divided into the following groups: Class I, Class II div. 1, Class II div. 2, and Class III. The number of palatal rugae was recorded, bilaterally. The length, pattern and orientation of three anterior-most primary rugae on both sides were recorded. Results: The mean age of the study sample was 17.8 ± 5.4 years. The mean number of the palatal rugae was 11.18 ± 2.5, with significant differences among different malocclusion groups. The length of the first rugae on left side and third rugae on both sides varied significantly among the groups (p< 0.05). Similarly, the pattern of palatal rugae was also found to be significantly different among the malocclusion groups. The right sided rugae did not have any significant difference in the orientation in different malocclusion groups; however, the left sided rugae showed significant differences among the four malocclusion groups (p< 0.001). Conclusions: The current study showed subtle differences in the palatal rugae pattern among the Angle's classes of malocclusion. Similarly, the length and orientation of some rugae were also found to be significantly different between malocclusion groups.


RESUMO Introdução: as rugas palatinas completam seu desenvolvimento ainda no início da vida intrauterina, enquanto as más oclusões dentárias na dentição permanente se estabelecem após vários anos de vida pós-natal. Objetivos: o presente estudo foi planejado para determinar se há associação entre o padrão das rugas palatinas e as más oclusões, segundo a classificação Angle. Métodos: um estudo transversal foi conduzido a partir dos modelos dentários pré-tratamento de 184 pacientes. A amostra foi dividida em quatro grupos: Classe I; Classe II, divisão 1; Classe II, divisão 2 e Classe III. O número de rugas palatinas foi registrado bilateralmente. O comprimento, padrão e a orientação das três rugas primárias mais anteriores de ambos os lados foram registrados. Resultados: a idade média da amostra desse estudo foi de 17,8 ± 5,4 anos. O número médio de rugas palatinas foi de 11,18 ± 2,5, com diferenças significativas entre os grupos de más oclusões. O comprimento da primeira ruga do lado esquerdo e da terceira ruga em ambos os lados variou significativamente entre os grupos (p< 0,05). De forma semelhante, o padrão das rugas palatinas também mostrou diferença significativa entre os grupos com diferentes má oclusões. As rugas do lado direito não apresentaram nenhuma diferença significativa de orientação nos diferentes grupos; no entanto, as rugas do lado esquerdo apresentaram diferenças significativas nos grupos estudados (p< 0,001). Conclusões: o presente estudo demonstrou diferenças sutis quanto ao padrão das rugas palatinas entre as classes de má oclusão definidas por Angle. Do mesmo modo, o comprimento e a orientação de algumas rugas também se apresentaram consideravelmente diferentes entre os grupos com diferentes má oclusões.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Adulto Jovem , Palato Duro/anatomia & histologia , Má Oclusão , Mucosa Bucal/anatomia & histologia , Estudos Transversais
14.
Ortho Sci., Orthod. sci. pract ; 12(48): 113-119, 2019. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-1048713

RESUMO

Resumo Introdução: Os sistemas CAD/CAM auxiliam ortodontistas na confecção de alinhadores estéticos e na colagem indireta (posicionamento virtual de bráquetes) em modelos digitais tridimensionais. Este estudo avaliou a precisão e validade do software eXceedTM. Métodos: Vinte modelos de gesso de pacientes foram digitalizados utilizando um escâner de mesa e os arquivos obtidos foram convertidos em estereolitografia pelo software OrthoAnalyserTM. Utilizando os modelos de gesso e digital, seis medidas foram aferidas: Largura Intermolares (LM), Largura Intercaninos (LC), Comprimento do Arco posterior (CA), Diâmetro da Coroa do Pré-Molar (DP), Altura da Coroa do Canino (AC) e Overjet (OJ). Os erros sistemáticos e aleatórios foram avaliados em análises das réplicas das mensurações. As diferenças foram avaliadas usando o teste t de Student. Os erros aleatórios foram quantificados usando o erro do método (V(Sd2/2n) e o Coeficiente de Correlação Intraclasse (ICC). Resultados: Duas das medidas das réplicas em modelos digitais (CA) e de gesso (LC) demostraram erros sistemáticos estatisticamente significativos. O ICC variou de 0,916 a 0,997. Os erros do método foram todos inferiores a 0,41 mm (0,22 mm). Os gráficos de Bland-Altman mostraram que as diferenças de repetitividade entre os dois métodos estavam dentro dos limites de concordância. Os valores DP (0,253 mm), LC (0,396 mm), AC (0,314 mm) e CA (0,359 mm) foram maiores em modelos de gesso do que nos modelos digitais. Conclusão: As medidas realizadas em ambos os métodos foram confiáveis e reprodutíveis, e as medidas dos modelos de gesso foram ligeiramente maiores do que os dos modelos digitais correspondentes (AU)


Abstract Introduction: CAD/CAM systems help orthodontists in the production of aesthetic aligners and in indirect bonding (virtual bracket positioning) in three-dimensional digital models. This study evaluated the accuracy and validity of the eXceedTM 3D software (Roosikrantsi, Tallinn, Estonia). Methods: Twenty patient plaster models were digitized by a desktop scanner, and the files obtained were converted to stereolithography by OrthoAnalyserTM software. Using the cast and digital models, six measurements were performed: Intermolar Width (LM); Intercanine Width (LC); Posterior Arch Length (CA); Premolar Crown Diameter (DP); Canine Crown Hight (AC) and Overjet (OJ). Intra-observer systematic differences between the replicates were described with mean absolute differences and standard errors (SE); differences were assessed using a paired Students t test. Random errors were quantified using the method error statistic (V[Sd2/2n]) and Intraclass Correlation Coefficient (ICC). Differences between methods was evaluated using Students t test. Results: Two of the measurements of the replicas in the digital model (CA) and in the plaster model (LC) showed statistically significant systematic errors. The ICC ranged from 0.916 to 0.997. The method errors were all less than 0.41 mm (0.22 mm). Bland-Altman plots showed that the differences of repeatability between the two methods were within the limits of agreement. The values DP (0.253 mm), LC (0.396 mm), AC (0.314 mm) and CA (0.359 mm) were higher in plaster models than in digital models. Conclusion: The measurements performed in both methods were reliable and reproducible, and plaster models measurements were slightly higher than those of the corresponding digital models. (AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Ortodontia , Tecnologia Odontológica , Desenho Assistido por Computador , Modelos Dentários , Precisão da Medição Dimensional
15.
J. health sci. (Londrina) ; 20(2)30/06/2018.
Artigo em Inglês | LILACS | ID: biblio-909318

RESUMO

Alginate is among the most used materials in dentistry to create teeth negative printing and reproduction. The goal of this study was to compare dimensional changes of alginate scanned impression materials. Thirty impressions of a standard typodont were performed using three types of alginate (Hydrogum 5; Jeltrate Plus and Avagel). The impressions were scanned by the scanner 3Shape R700T and scans were performed immediately after molding. The analysis of digital models were performed at OrthoAnalyzer ™ 3D software. Measurements were carried out in relation to the transverse dimension (intercanine, interpremolares and intermolar). Method error was evaluated through the Intraclass Correlation Coefficient (ICC) and Bland-Altman. One-way ANOVA, Dunnet Post-test were used to compare the different groups in relation to Typodont (gold standard) for the different outcome variables. The data were tabulated in Statistical Package for Social Sciences version 20.0 and Minitab 17.0 softwares to compare groups. The significance level was 5%. The posterior transverse variables (D1PM, D2PM and DM) presented a statistically significant difference regarding the gold standard (Typodont) for the plaster models performed after the Avagel molding. In the digital models performed just after molding, only in DM, the Avagel material group presented values statistically higher than the control group. The alginates Hydrogum 5 and Jeltrate Plus presented dimensions closer to the gold standard.(AU).


O alginato está entre os materiais de moldagem mais utilizados na Odontologia para criar impressão e reprodução negativa dos dentes. O objetivo desse trabalho foi comparar alterações transversais de três marcas comerciais de alginato (Hydrogum, Jeltrate e Avagel) em moldes de alginatos. Trinta moldes de um Typodont padrão foram realizados, utilizando três tipos de alginato (Hydrogum 5; Jeltrate Plus e Avagel). Os moldes foram escaneados por meio do scanner 3Shape R700T e os escaneamentos realizados logo após a moldagem e logo após a obtenção dos modelos de gesso. As análises dos modelos digitais foram realizadas no software OrthoAnalyzer™ 3D. Foram realizadas mensurações em relação à discrepância transversal (inter-caninos, inter-primeiro pré-molar, inter-segundo pré-molar e inter-molares). O erro do método foi avaliado por meio do Coeficiente de Correlação Intraclasse (CCI) e Bland-Altman. Utilizou-se Análise de Variância (one-way ANOVA, Pós-teste Dunnet) para comparação dos diferentes grupos em relação ao typodont (padrão-ouro) para as diferentes variáveis de desfecho. A análise estatística foi realizada nos programas Statistical Package for Social Sciences versão 20.0 e no programa Minitab 17.0 para comparação dos grupos. O nível de significância foi de 5%. As variáveis transversais posteriores (D1PM; D2PM e DM) apresentaram diferença estatisticamente significante em relação ao padrão-ouro (manequim) para os modelos de gesso realizados após a moldagem com Avagel. Nos modelos digitais realizados logo após a moldagem, apenas na DM, o grupo do material Avagel apresentou valores estatisticamente maiores do que o grupo controle. Os alginatos Hydrogum 5 e Jeltrate Plus apresentaram dimensões mais próximas do padrão-ouro.(AU).

16.
HU Rev. (Online) ; 44(1): 97-113, 2018.
Artigo em Português | LILACS | ID: biblio-986572

RESUMO

Introdução: Os modelos ortodônticos digitais são alternativas ao uso de modelos ortodônticos em gesso. Devido sua importância no diagnóstico, faz-se necessário averiguar a precisão dos softwares de modelos ortodônticos digitais disponíveis no mercado. Objetivo: Evidenciar qual software de modelos ortodônticos digitais possui maior confiabilidade. Material e métodos: Foi realizada busca sistemática nas seguintes bases de dados eletrônicas: Scopus, PubMed, Web of Science, Embase e Cochrane, Grey Literature e Clinical Trials, sem limitações quanto ao ano de publicação ou idioma. Foram incluídos estudos laboratoriais que utilizaram softwares destinados a geração de modelos ortodônticos digitais, comparando-os com modelos ortodônticos em gesso. Após seleção por título e resumo, os artigos potencialmente elegíveis foram lidos na íntegra. A qualidade metodológica e o risco de viés dos artigos incluídos foram avaliados de acordo com as descrições dos modelos, técnicas de medição e análises estatísticas. A qualidade metodológica foi classificada em alta, moderada ou baixa. Resultados: 13.333 artigos foram encontrados nas bases de dados utilizadas. Após a aplicação dos critérios de elegibilidade e remoção de duplicações, restaram apenas 41 artigos. 29 foram considerados de qualidade moderada e 12 de alta qualidade. A classificação quanto à confiabilidade variou de menos confiaveis, equivalentes e a mais confiaveis. Apresentando diferenças estatisticas em suas mensurações (p<0,05); sem significância clínica. Conclusão: os modelos ortodônticos digitais apresentaram mensurações acuradas, reprodutíveis e confiáveis quando comparado ao método convencional utilizando modelos de gesso.


Introduction: Digital models are an alternative for the use of orthodontic models in plaster. Due to its importance in the orthodontic dignified, it is necessary to ascertain the accuracy of the software of digital orthodontic models available in the market. Objective: To show which software of digital orthodontic models has greater reliability. Material and methods: A systematic search was performed in the following electronic databases: Scopus, PubMed, Web of Science, Embase and Cochrane, Gray Literature and Clinical Trials, with no limitations on year of publication or language. We included laboratory studies using digital orthodontic models, comparing them with orthodontic models of plaster through the evaluation of reliability through measurement techniques. After selection by title and abstract, potentially eligible articles have been read in full. The methodological quality and risk of bias of the included articles were evaluated according to the descriptions of the models, measurement techniques and statistical analyzes. The methodological quality was classified as high, moderate or low. Results: 13,333 articles were found in the databases used. After applying the eligibility criteria and removing duplicates, only 41 articles remained. 29 were considered of moderate quality and 12 of high quality. The ranking of digital models for reliability ranged from less reliable, equivalent, and more reliable. Presenting statistical differences in their measurements (p <0.05), without clinical significance. Conclusion: The measurements made in digital models can be as accurate, reproducible and reliable as the conventional method using plaster models.


Assuntos
Ortodontia , Modelos Dentários , Software , Imageamento Tridimensional
17.
Bauru; s.n; 2018. 62 p. ilus, tab.
Tese em Inglês | LILACS, BBO - Odontologia | ID: biblio-905295

RESUMO

This study aimed to present two papers that show the alterations in the dental arch dimensions of children with cleft lip and palate before and after the primary surgeries. The first study aimed to evaluate the dimensional alterations of the dental arches of neonates with unilateral complete cleft lip and palate before and after two different primary plastic surgeries. The sample was composed of 114 dental casts of 57 children, divided into two groups: Group 1 ­ 26 neonates whose lip closure was accomplished at 3 months of life by Millard´s technique and the anterior and posterior palate closure by von Langenback's technique (VL); Group 2 ­ 31 neonates whose lip closure, nose's ala correction, and anterior palate closure were accomplished of life by Millard´s technique, Mcomb's or Skoog's technique, and vomer's flap, respectively at 3 months of life; posterior palate closure was accomplished by VL at 12 months of life. The dental casts were analyzed at two phases: (T1) pre-cheiloplasty and (T2) one year after palatoplasty. The second study aimed to evaluate morphometrically and longitudinally the alterations of the dental arch dimensions of children with cleft lip and palate. The sample was composed by digital dental casts of children with complete cleft lip (Group 1), complete cleft lip and palate (Group 2), and complete cleft palate (Group 3), obtained at pre-cheiloplasty (T1), pre-palatoplasty (T2), and one year after palatoplasty (T3). The measurements of the dental arch dimensions of both studies were performed directly on the digitized models and analyzed by Appliance Designer software. The following dimensions were obtained: intercanine distance, inter-tuberosity distance, anterior arch length, and total arch length. A previously trained and calibrated examiner performed the assessments of both studies. To verify the alterations among groups, t test and ANOVA followed by Tukey was applied. In the first study, no statistically significant differences occurred at pre-cheiloplasty. At one year after palatoplasty, Group 1 had statistically significant greater anterior-posterior arch length (P=0.002) than Group 2. This suggested that the outcomes of the different surgical techniques may cause alterations in the dental arch growth and development of neonates with cleft lip and palate. In the second study, in Group 1, the distances C-C', T-T', and I-TT' were statistically greater at T2 than at T1. In Group 2, the distances C-C' and I-CC' were smaller at T3. T-T' distance decreased and I-TT' distance increased at all phases. In Group 3, the C-C', T-T', and I-TT' distances were statistically greater at T3. The intergroup comparisons showed that C-C' and T-T' distances were statistically greater in Group 1; C-C' and I-CC' distances were statistically smaller in Group 2; and I-TT' distance was statistically greater in Group 3. The longitudinal evaluation of the changes occurred in the dental arches of children with different oral cleft types showed that cheiloplasty and palatoplasty caused the most alterations in the growth and development of the maxillary dimensions of children with complete cleft lip and palate.(AU)


O propósito deste estudo foi apresentar dois artigos que mostram as alterações das dimensões dos arcos dentários de crianças com fissura labiopalatina antes e depois das cirurgias primárias. O primeiro estudo foi proposto para avaliar as alterações dimensionais dos arcos dentários de neonatos com fissura labiopalatina antes e após a realização de duas técnicas distintas de cirurgias plásticas primárias. A amostra foi composta de 114 modelos dentários em gesso de 57 crianças, divididos em dois grupos: Grupo I ­ 26 neonatos, fechamento do lábio realizado aos 3 meses de vida pela técnica de Millard e palato total aos 12 meses, pela técnica de von Langenback (VL); Grupo II ­ 31 neonatos, fechamento do lábio pela técnica de Millard aos 3 meses de vida, correção de asa nasal (técnicas de Mcomb ou Skoog) e palatoplastia anterior com retalho de vômer aos 3 meses. A palatoplastia posterior foi realizada aos 12 meses pela técnica VL. Os modelos foram analisados em 2 fases: (F1) pré-queiloplastia e (F2) 1 ano pós-palatoplastia. No segundo estudo o objetivo foi realizar uma avaliação longitudinal das alterações das dimensões dos arcos dentários de crianças com fissura labiopalatina. A amostra foi composta de modelos digitais de crianças com fissura completa de lábio (Grupo 1), completa de lábio e palato (Grupo 2), e completa de palato (Grupo 3), obtidos nas fases de pré-queiloplastia (Fase 1), pré-palatoplastia (Fase 2), 1 ano póspalatoplastia (Fase 3). As medidas das dimensões dos arcos dentários nos dois estudos foram realizadas nos modelos digitalizados e analisados utilizando software Appliance Designer. As seguintes dimensões foram obtidas: distância intercaninos, distância intertuberosidade, comprimento anterior do arco dentário e comprimento total do arco. Um avaliador previamente calibrado e treinado realizou as avaliações para os dois estudos. Foi aplicado o Teste t e a Análise de Variância, seguida do Teste de Tukey. Para o primeiro estudo não houve diferença estatisticamente significante na fase pré-queiloplastia entre os grupos. Na fase 1 ano pós-palatoplastia houve diferença para o comprimento anteroposterior do arco dentário (p=0,002), entre os grupos, com valores maiores para o grupo I. Para o segundo estudo, no Grupo 1, as distâncias C-C', T-T' e I-TT' apresentaram diferença estatisticamente significante entre a F1 e F2, com aumento na F2. Para o Grupo 2, houve diferença estatisticamente significante em todas as fases avaliadas. As distâncias C-C' e I-CC' apresentaram menor valor na F3, T-T' diminuiu em todas as fases, e I-TT' aumentou em todas as fases. No Grupo 3, as distâncias C-C', T-T' e I-TT' mostraram diferença estatisticamente significante com aumento na F3. Quando avaliadas as medidas entre os grupos e fases, C-C' e T-T' mostraram um valor maior para o Grupo 1. A comparação entre F2 e F3 mostraram para as distâncias C-C' e I-CC' valor menor para o Grupo 2, e I-TT' foi maior para o Grupo 3. As avaliações longitudinais nos arcos dentários mostraram que a queiloplastia e palatoplastia causam maiores alterações de crescimento e desenvolvimento maxilares de pacientes com fissura completa de lábio e palato.(AU)


Assuntos
Humanos , Animais , Masculino , Lactente , Pré-Escolar , Fenda Labial/patologia , Fissura Palatina/patologia , Arco Dental/patologia , Pontos de Referência Anatômicos , Fenda Labial/cirurgia , Fissura Palatina/cirurgia , Modelos Dentários , Imageamento Tridimensional , Estudos Longitudinais , Valores de Referência , Fatores Sexuais
18.
Dental press j. orthod. (Impr.) ; 22(6): 68-73, Nov.-Dec. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-891114

RESUMO

ABSTRACT Introduction: Plaster dental casts are routinely used during clinical practice to access maxillary dental arch form and assist on fabrication of individualized orthodontic archwires. Recently introduced, digital model technology may offer a limitation for the obtainment of a dental physical record. In this context, a tool for dental arch form assessment for chairside use is necessary when employing digital models. In this regard, paper print of the dental arch seems thus to be useful. Methods: In the present study, 37 lower arch models were used. Intercanine and intermolar widths and dental arch length measurements were performed and compared using plaster dental casts, digital models and paper print image of the models. Ortho Insight 3D scanner was employed for model digitalization. Results: No statistically significant differences were noted regarding the measurements performed on the plaster or digital models (p> 0.05). Paper print images, however, showed subestimated values for intercanine and intermolar widths and overestimated values for dental arch length. Despite being statistically significant (p< 0.001), the differences were considered clinically negligible. Conclusion: The present study suggests that paper print images obtained from digital models are clinically accurate and can be used as a tool for dental arch form assessment for fabrication of individualized orthodontic archwires.


RESUMO Introdução: os modelos de gesso são usados rotineiramente, durante a prática clínica, para avaliação da forma da arcada inferior e para auxiliar na confecção de arcos ortodônticos individualizados. A tecnologia dos modelos digitais, introduzida recentemente, pode oferecer uma limitação na obtenção de um registro físico da arcada dentária. Assim, quando se utilizam modelos digitais, faz-se necessária uma ferramenta clínica para obtenção da forma da arcada. Com essa finalidade, poderia-se imprimir, em papel, uma imagem da arcada dentária obtida a partir do modelo de gesso. Métodos: nesse estudo, 37 modelos da arcada inferior foram utilizados, nos quais foram realizadas medições das distâncias intercaninos, intermolares e comprimento da arcada; sendo, então, comparadas entre modelos de gesso, modelos digitalizados com um scanner Ortho Insight 3D e imagens impressas em folha de papel A4. Resultados: não foram encontradas diferenças estatisticamente significativas nas medidas realizadas nos modelos de gesso e modelos digitais (p > 0,05). As imagens impressas, contudo, mostraram valores subestimados para as distâncias intercaninos e intermolares, e superestimados para o comprimento da arcada. Apesar de serem estatisticamente significativas (p< 0,001), as diferenças foram consideradas clinicamente insignificantes. Conclusão: o presente estudo sugere que as imagens obtidas por meio dos modelos digitais e impressas em papel são clinicamente acuradas e podem ser utilizadas como uma ferramenta auxiliar na confecção dos arcos ortodônticos individualizados.


Assuntos
Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Arco Dental/anatomia & histologia , Arco Dental/diagnóstico por imagem , Modelos Dentários , Mandíbula/anatomia & histologia , Ortodontia/instrumentação , Ortodontia/métodos , Software , Moldes Cirúrgicos , Reprodutibilidade dos Testes , Análise de Variância , Técnica de Moldagem Odontológica , Tecnologia Odontológica , Processos de Cópia , Impressão Tridimensional , Mandíbula/diagnóstico por imagem , Modelos Anatômicos
19.
Rev. Odontol. Araçatuba (Impr.) ; 38(3): 27-33, set.-dez. 2017. tab, graf, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-881656

RESUMO

Este é um estudo cuja finalidade foi demonstrar as possíveis deformações que podem ocorrer nos modelos obtidos de moldes de alginato, dependentes da forma de vazamento. Foram obtidos 20 moldes de alginato da marca Hydrogum 5 (Zhermack, Badia Polesine, Italy), através de um modelo de resina acrílica previamente preparado, divididos em dois grupos de 10: com vazamento invertido e não invertido. Os modelos foram analisados por fotografias, mensurados por um programa de computação (Corel Draw X3 Graphics Suíte (Corel Corporation ­ USA) e comparados com o modelo padrão. Os resultados mostraram que os vazamentos invertidos e não invertidos apresentaram valores clínicos diferentes do modelo padrão, mas que na comparação entre as técnicas, dos quatro segmentos analisados, apenas um apresentou diferença estatística significante(AU)


This is a study whose purpose was to demonstrate the possible deformations that may occur in the models obtained from alginate molds, depending on the form of flow. 20 alginate molds of Hydrogum 5 (Zhermack, Badia Polesine, Italy) were obtained through a previously prepared acrylic resin model, divided into two groups of 10: with inverted and non inverted casting. The models were analyzed by photographs, measured by a computer program (Corel Draw X3 Graphics Suite (Corel Corporation - USA) and compared with the standard model.The results showed that inverted and non inverted flow presented clinical values different from the standard model, But that in the comparison between the techniques, of the four analyzed segments, only one presented significant statistical difference(AU)


Assuntos
Materiais para Moldagem Odontológica , Alginatos
20.
Ortho Sci., Orthod. sci. pract ; 10(38): 45-48, 2017.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-837357

RESUMO

Modelos de estudo propiciam uma avaliação tridimensional dos arcos dentários superior e inferior, bem como da relação oclusal, sendo fundamentais ao diagnóstico e plano de tratamento de pacientes. Com o avanço da tecnologia e devido algumas desvantagens encontradas nos modelos tradicionais, a Ortodontia passou a empregar modelos digitais em que as análises antes realizadas com paquímetros são agora obtidas através de softwares. O presente estudo teve como objetivo avaliar a confiabilidade da análise de Bolton e da discrepância de modelos realizadas em modelos digitais. Quinze pares de modelos de gesso de pacientes foram selecionados e mesurados através de um paquímetro digital (Kingtools, São Paulo, Brasil, 150 mm, precisão 0,01 mm/.0005'). Posteriormente, os modelos foram escaneados pelo scanner Go Digital (Open Technologies, Itália). Para os respectivos modelos digitais obtidos, o software Maslab (Istituto di Scienza e Tecnologie de'll Informazione, Pisa, Itália) foi utilizado para medição. Todas as medidas e análises foram realizadas por um único examinador. Conduziu-se a análise estatística pelo software Graph Pad Prism 5.2 (GraphPad Software, Inc. Califórnia), e aplicou-se o teste de Mann Whitney, com intervalo de confiança de 95% e significância estabelecida em p<0,05.(AU)


Dental models provide a three-dimensional view of the upper and lower arches and the occlusal relationship, they are essential tools for the diagnosis and patient treatment plan. Due to technology advancement and some disadvantages found in traditional models, orthodontics started to use digital models (emodels) in which the analysis previously performed with calipers are now obtained through softwares. This study aimed to evaluate the reliability of Bolton analysis and the discrepancy of models performed in digital models. Fifteen pairs of patients plaster models were selected and measured with a digital caliper (Kingtools, São Paulo, Brazil, 150 mm, precision of 0,01 mm/.0005). The models were then scanned by Go Digital Scanner (Open Technologies, Italy). For the respective digital models obtained, Maslab software (Istituto di Scienza e Tecnologie de'll Informazione, Pisa, Italy) was used for measuring. All measurements and analyses were performed by a single examiner. The statistical analysis was conducted through the software Graph Pad Prism 5.2 (GraphPad Software, Inc. California) and the Mann-Whitney test was applied, with confidence interval of 95% and significance level of p<0,05. (AU)


Assuntos
Modelos Dentários , Diagnóstico por Computador , Ortodontia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA