1.
Rev. latinoam. enferm. (Online) ; 32: e4209, 2024. graf
Artigo em Inglês | LILACS, BDENF - Enfermagem | ID: biblio-1565568

RESUMO

Objective: to analyze the integrity of N95/PFF2 masks in relation to fiber morphology, porosity, cracks and micro holes, as well as identify visible damage to their structure and components, after seven- and fifteen-day reuse protocols. Method: cross-sectional study. Structural and morphological characteristics of a new N95/PFF2 mask were analyzed in comparison with N95/PFF2 masks (n=10) used in seven- and fifteen-day protocols, through visual inspection and scanning electron microscopy. Results: upon visual inspection, following the seven-day protocol, 40% and 60% of the N95/PFF2 masks showed, respectively, personal identification marks and external and internal dirt. Additionally, 20% exhibited loosening and/or tearing of the straps, while 100% showed some type of damage to the nose clips. In the fifteen-day protocol, all N95/PFF2 masks had dirt, loose straps and damaged nose clips, and 80% had folds. Electronic microscopy revealed an increase in pores and loosening in the weaves from seven days onwards, extending up to fifteen days, with the presence of micro holes and residues. Conclusion: the reuse of N95/PFF2 masks affects their structural and morphological integrity. It is crucial to carry out tests to measure the impact of this practice on the safety of health professionals.


Objetivo: analizar la integridad de mascarillas N95/PFF2 con relación a la morfología de las fibras, porosidad, grietas y microagujeros, así como identificar daños visibles en su estructura y componentes, luego de protocolos de reutilización de siete y quince días. Método: estudio transversal. Se analizaron las características estructurales y morfológicas de una mascarilla N95/PFF2 nueva en comparación con las mascarillas N95/PFF2 (n=10) utilizadas en protocolos de siete y quince días, mediante inspección visual y microscopía electrónica de barrido. Resultados: tras la inspección visual, siguiendo el protocolo de siete días, el 40% y el 60% de las mascarillas N95/PFF2 mostraron, respectivamente, marcas de identificación personal y suciedad externa e interna. Además, el 20% presentó aflojamiento y/o desgarro de las correas de sujeción, mientras que el 100% presentó algún tipo de daño en los clips nasales. En el protocolo de quince días, todas las mascarillas N95/PFF2 tenían suciedad, correas de sujeción sueltas y clips nasales dañados, y el 80% tenía pliegues. La microscopía electrónica reveló un aumento de poros y aflojamiento en las tramas a partir de los siete días, extendiéndose hasta los quince días, con presencia de microagujeros y residuos. Conclusión: la reutilización de las mascarillas N95/PFF2 compromete su integridad estructural y morfológica. Es crucial realizar pruebas para medir el impacto de esta práctica en la seguridad de los profesionales de la salud.


Objetivo: analisar a integridade das máscaras N95/PFF2 em relação à morfologia das fibras, porosidade, fissuras e micro furos, bem como identificar danos visíveis em sua estrutura e componentes, após protocolos de reutilização de sete e quinze dias. Método: estudo transversal. Características estruturais e morfológicas de uma máscara N95/PFF2 nova foram analisadas em comparação com máscaras N95/PFF2 (n=10) utilizadas em protocolos de sete e quinze dias, por meio da inspeção visual e microscopia eletrônica de varredura. Resultados: na inspeção visual, seguindo o protocolo de sete dias, 40% e 60% das máscaras N95/PFF2 apresentaram, respectivamente, marcas de identificação pessoal e sujidades externas e internas. Além disso, 20% exibiram afrouxamento e/ou rompimento das tiras de fixação, enquanto 100% mostraram algum tipo de dano nos clipes nasais. No protocolo de quinze dias, todas as máscaras N95/PFF2 apresentavam sujidade, tiras de fixação frouxas e clipes nasais comprometidos; 80% possuíam dobras. A microscopia eletrônica revelou aumento dos poros e afrouxamento nas tramas a partir de sete dias, ampliando-se até quinze dias, com presença de micro furos e detritos. Conclusão: a reutilização das máscaras N95/PFF2 compromete a integridade estrutural e morfológica. É crucial realizar testes para mensurar o impacto dessa prática na segurança dos profissionais de saúde.


Assuntos
Microscopia Eletrônica de Varredura , Saúde Ocupacional , Pessoal de Saúde , Reutilização de Equipamento , Equipamento de Proteção Individual , Respiradores N95
2.
Braz. j. oral sci ; 23: e241938, 2024. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1532506

RESUMO

Aim: To evaluate changes in the surface roughness and morphology of a nanofilled composite following toothbrushing with a whitening (WT) or regular toothpaste (RT), alone or combined with 35% hydrogen peroxide bleaching (HP). Methods: Seventy disc-shaped nanofilled composite (Filtek Z350XT) specimens were randomly divided into groups (n=10): WT, RT, TB (without toothpaste ­ control) or the combinations WT/ HP, RT/HP, TB/HP and HP. All groups underwent toothbrushing simulation (60,000 cycles) and bleaching treatment (4 sessions). Mean surface roughness (Ra, µm) was measured before (T0) and after treatments (TB). Surface morphology was assessed by scanning electron microscopy (SEM) at TB. Mean Ra was analyzed using general mixed models and multiple comparisons by the Tukey-Kramer test (α=5%). Results: HP caused no surface roughness changes on the nanofilled composite after treatment (p>0.05). RT toothbrushing, combined or not with HP, increased the surface roughness (p<0.05). WT and WT/ HP protocols had no effect on the surface roughness of the composite (p>0.05). The nanofilled composite submitted to RT toothbrushing combined with HP (RT/HP) presented substantial surface alterations under SEM, showing deep depressions and round-shaped defects. Toothbrushing with RT combined with the bleaching agent increased exposure of the inorganic fillers. Conclusion: WT toothbrushing, regardless of HP combination, or the single HP protocol had no effect on the surface roughness of the nanofilled composite. However, RT combined with HP negatively affected surface roughness and presented the most noticeable surface changes among groups


Assuntos
Clareamento Dental , Cremes Dentais , Microscopia Eletrônica de Varredura , Resinas Compostas , Peróxido de Hidrogênio
3.
Acta cir. bras ; Acta cir. bras;39: e392224, 2024. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1556673

RESUMO

Purpose: To evaluate, by quantitative and qualitative methods, the glomerular ultrastructure in Wistar rats fed a cafeteria diet. Methods: Male Wistar rats were divided into two groups at 21 days of age: control (C, n = 10) and cafeteria diet (CAF, n = 8). The animals were followed up until 5 months of age, followed by euthanasia. The blood, kidneys, and fat deposits­­epididymal, retroperitoneal, and subcutaneous­­were extracted and analyzed. Data were analyzed by Student's t test, and p < 0.05 was considered statistically significant. Results: The cafeteria diet promoted glucose intolerance, hyperglycemia (p < 0.0001), and deposition of retroperitoneal fat (p < 0.005). Scanning electron microscopy revealed that the length of the foot process was similar in both groups. The quantitative analyses by transmission electron microscopy revealed that the cafeteria diet reduced the thickness of the glomerular basement membrane (p < 0.05). Conclusions: The intake of lipids and simple carbohydrates were found to be associated with alteration in the glomerular ultrastructure. However, more studies are needed to evaluate not only the effects of high-protein and high-fat diets on components of the glomerular filtration barrier, but also renal physiology.


Assuntos
Animais , Ratos , Microscopia Eletrônica de Varredura , Ratos Wistar , Dieta , Rim
4.
5.
São Paulo med. j ; São Paulo med. j;141(6): e2022508, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1442191

RESUMO

ABSTRACT BACKGROUND: Primary ciliary dyskinesia (PCD) is a rare and heterogeneous disease that is difficult to diagnose and requires complex and expensive diagnostic tools. The saccharin transit time test is a simple and inexpensive tool that may assist in screening patients with PCD. OBJECTIVES: This study aimed to compare changes in the electron microscopy findings with clinical variables and saccharin tests in individuals diagnosed with clinical PCD (cPCD) and a control group. DESIGN AND SETTING: An observational cross-sectional study was conducted in an otorhinolaryngology outpatient clinic from August 2012 to April 2021. METHOD: Patients with cPCD underwent clinical screening questionnaires, nasal endoscopy, the saccharin transit time test, and nasal biopsy for transmission electron microscopy. RESULTS: Thirty-four patients with cPCD were evaluated. The most prevalent clinical comorbidities in the cPCD group were recurrent pneumonia, bronchiectasis, and chronic rhinosinusitis. Electron microscopy confirmed the clinical diagnosis of PCD in 16 of the 34 (47.1%) patients. CONCLUSION: The saccharin test could assist in screening patients with PCD due to its association with clinical alterations related to PCD.

7.
Braz. j. oral sci ; 21: e224013, jan.-dez. 2022. ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1354702

RESUMO

Aim: The aim of the study was to evaluate the cleaning of mandibular incisors with WaveOne Gold® (WO) under different preparation techniques. Methods: A total of 210 human mandibular incisors were selected and divided into seven groups (n = 30), prepared by WO single-files (Small 20/.07 ­ WOS; Primary 25/.07 ­ WOP; Medium 35/.06 ­ WOM; or Large 45/.05 - WOL) and sequential-file techniques (WOS to WOP; WOS to WOM; and WOS to WOL). Further subdivision was made according to irrigation protocol: control group (manual irrigation - CON), E1 Irrisonic® - EIR, and EDDY® - EDD. Debris removal and the smear layer were evaluated by scanning electron microscopy. Data were analyzed by using Spearman's correlation test. The significance level was set at 5%. Results: For debris and smear layer removal, WOS and WOP, EIR differed from CON and EDD (p <0.05). Conclusion: Regardless of the instrumentation used, the agitation of the irrigant solution provided better cleanability. These findings reinforce the need for agitation techniques as adjuvants in cleaning root canal systems in mandibular incisors


Assuntos
Irrigantes do Canal Radicular , Microscopia Eletrônica de Varredura , Preparo de Canal Radicular , Endodontia
8.
J Dent ; 127: 104348, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36280006

RESUMO

OBJECTIVES: This in vitro study aimed to evaluate the effect of different times and concentrations of hydrofluoric acid etching on the surface of indirect restorative materials obtained from blocks used in CAD-CAM technology. METHODS: Specimens (4 mm × 4 mm × 0.8 mm) were obtained for each indirect restorative material: zirconia-reinforced lithium monosilicate ceramic (Celtra Duo), nanoceramic resin (Lava Ultimate), and polymer-infiltrated ceramic network material (Vita Enamic). The materials were submitted to etching with 5% or 10% hydrofluoric acid for 20, 40, 60, or 90 s. A control group for each material was evaluated without any surface treatment, totaling nine experimental groups for each material (n = 10). The specimens were evaluated for surface roughness (Ra and Rz), confocal optical microscopy, the contact angle (θ), surface free energy (γs), total free interaction energy (∆G) using a goniometer, and microshear bond strength to resin cement. Specimen images were obtained using scanning electron microscopy, confocal optical microscopy, and atomic force microscopy. Data on the surface roughness, the contact angle, surface free energy, total free interaction energy, and bond strength were subjected to two-way ANOVA and Tukey´s test (α=0.05). RESULTS: In general, Celtra Duo showed better results after etching with 10% hydrofluoric acid for 40 or 60 s. Lava Ultimate showed better performance after etching with 10% hydrofluoric acid for 20 or 40 s, whereas Vita Enamic showed better results after etching with 5% hydrofluoric acid for 90 s. CONCLUSION: Each material showed different characteristics after etching with hydrofluoric acid. Knowledge of the proper protocol for each material is essential to ensure improvements in the adhesion process and durability of indirect restorations. In general, Celtra Duo presented mechanical properties superior to those of Lava Ultimate and Vita Enamic. CLINICAL SIGNIFICANCE: Specific etching protocols must be recommended for each indirect material because longer exposure to hydrofluoric acid can jeopardize the surface, thus affecting the mechanical and bond strength properties.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Ácido Fluorídrico/química , Porcelana Dentária/química , Teste de Materiais , Propriedades de Superfície , Materiais Dentários/química , Cimentos de Resina/química , Cerâmica/química , Desenho Assistido por Computador
9.
An. bras. dermatol ; An. bras. dermatol;97(2): 240-242, Mar.-Apr. 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1374243

RESUMO

Abstract Panitumumab is a monoclonal antibody against the epidermal growth factor receptor used in metastatic colorectal cancer; in addition to tumor cells, it acts on epidermal keratinocytes and on the outer root sheath and presents skin toxicity in up to 90% of cases. A scanning electron microscope was used to examine the eyelashes and hairs of a 65-year-old patient with eyelash trichomegaly, curly hair, and paronychia undergoing treatment with panitumumab. Grooving in the hair shafts were identified, which were more evident in the eyelashes. Similar to oral epidermal growth factor inhibitors (erlotinib and gefitinib), panitumumab can cause acquired pili canaliculi.

10.
An Bras Dermatol ; 97(2): 240-242, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35042642

RESUMO

Panitumumab is a monoclonal antibody against the epidermal growth factor receptor used in metastatic colorectal cancer; in addition to tumor cells, it acts on epidermal keratinocytes and on the outer root sheath and presents skin toxicity in up to 90% of cases. A scanning electron microscope was used to examine the eyelashes and hairs of a 65-year-old patient with eyelash trichomegaly, curly hair, and paronychia undergoing treatment with panitumumab. Grooving in the hair shafts were identified, which were more evident in the eyelashes. Similar to oral epidermal growth factor inhibitors (erlotinib and gefitinib), panitumumab can cause acquired pili canaliculi.


Assuntos
Pestanas , Doenças do Cabelo , Idoso , Pestanas/patologia , Cabelo/patologia , Doenças do Cabelo/induzido quimicamente , Doenças do Cabelo/patologia , Humanos , Microscopia Eletrônica de Varredura , Panitumumabe/efeitos adversos
11.
An Bras Dermatol ; 97(1): 58-62, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34839987

RESUMO

McCune - Albright syndrome is a genetic disease with cutaneous mosaicism caused by post-zygotic activating mutations in GNAS locus, it has a triad of fibrous bone dysplasia, café-au-lait macules and precocious puberty. We examined a 22-year-old female patient with café au lait spot in right side of the abdomen, with a chessboard - like distribution, extending to right thigh with geographical contours, she has also an ovarian cyst, scoliosis and truncal obesity. Biopsies were taken from the hyperpigmented area and processed for light microscopy and for transmission electron microscopy. Light microscopy showed increased melanin pigment with HE staining. Immunohistochemistry with melanocytic markers (HMB-45 and Melan-A) revealed a normal number of melanocytes. Transmission electron microscopy demonstrated normal epidermal structures, such as desmosomes, cytokeratin filaments and hemidesmosomes. With high magnifications an irregular melanossomal contour was seen, with some indentations in their outline.


Assuntos
Displasia Fibrosa Óssea , Displasia Fibrosa Poliostótica , Puberdade Precoce , Adulto , Manchas Café com Leite , Feminino , Displasia Fibrosa Poliostótica/diagnóstico , Humanos , Microscopia Eletrônica de Transmissão , Adulto Jovem
12.
Perfusion ; 37(2): 144-151, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33570010

RESUMO

INTRODUCTION: Arterial filter is the part of the cardiopulmonary bypass circuit where blood cells are exposed to high mechanical stress and where cellular aggregates may fasten in large quantities. The aim of this study was to analyse blood cell adhesiveness in the arterial filter through scanning electron microscopy and real-time PCR assay. METHODS: Prospective, clinical and observational study performed on 28 patients undergoing cardiac surgery with cardiopulmonary bypass. Arterial filters were analysed by scanning electron microscopy. Real-time PCR assay was performed in extracted material from the arterial filters for analysis of platelet GPIb and CD45 leucocyte gene expression. Blood coagulation was analysed during cardiopulmonary bypass. Patients were followed until hospital discharge or 28 days after surgery. RESULTS: All studied arterial filters used in the subject patients showed a degree of adhesion from blood elements at scanning electron microscopy. All studied filters were positive for platelets GPIb gene expression and 15% had CD45 leucocyte gene expression. The GPIb platelet gene expression in blood lowered at the end of cardiopulmonary bypass (p = 0.019). There was negative correlation between blood GPIb platelet gene expression and Clot SR (HEPSCREEN2 ReoRox®) (rho = 0.635; p = 0.027). The filter fields count was correlated to the D-dimer dosage (rho = 0.828; p < 0.001). CONCLUSION: There was adhesion of blood elements, especially nucleated platelets, on all arterial filters studied. Although the arterial filter worked as a safety device, that possibly prevented arterial embolisation, it may also have caused greater hyperfibrinolysis during cardiopulmonary bypass.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Células Sanguíneas , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Adesão Celular , Humanos , Microscopia Eletrônica de Varredura , Estudos Prospectivos , Reação em Cadeia da Polimerase em Tempo Real
13.
Rev. Esc. Enferm. USP ; Rev. Esc. Enferm. USP;56: e20210552, 2022. graf
Artigo em Inglês, Português | LILACS, BDENF - Enfermagem | ID: biblio-1365410

RESUMO

ABSTRACT Objective: To analyze the microbiological and microstructural part of indwelling urinary catheters and their association with urinary tract infection prevention. Method: This is a cross-sectional study, from June to December 2020, in which 42 indwelling urinary catheter tips and sterile urine samples were collected for analysis of crystals in optical microscopy and biofilms in scanning electron microscopy. Culture analysis and specification of the type of bacteria were performed. Results: It was found that 35.71% of the samples had mature biofilm adhered to the catheter tip. Biofilms of Proteus mirabilis, Enterococcus faecalis, Staphylococcus epidermidis, Enterococcus faecium and Enterobacter cloacae stood out. The presence of magnesium-ammonium-phosphate crystal was associated with the presence of urinary tract infection and with Proteus mirabilis. There was a significant association (p = 0.001) between the use of prophylactic antibiotics versus urine culture >105 CFU/mL. Conclusion: The analyzes contributed to clinical practice, as it reinforces the development of effective and monitored strategies on cultures and urinary tract infection prevention associated with indwelling urinary catheters.


RESUMEN Objetivo: Analizar la parte microbiológica y microestructural de los catéteres urinarios permanentes y su asociación con la prevención de la infección del tracto urinario. Método: Transversal, de junio a diciembre de 2020, en el que se recolectaron 42 puntas de sonda urinaria permanente y muestras de orina estéril para análisis de cristales en microscopía óptica y biopelículas en microscopía electrónica de barrido. Se realizaron análisis de cultivo y especificación del tipo de bacteria. Resultados: Se encontró que el 35,71% de las muestras presentaban biopelícula madura adherida a la punta del catéter. Se destacaron las biopelículas de Proteus mirabilis, Enterococcus faecalis, Staphylococcus epidermidis, Enterococcus faecium y Enterobacter cloacae. La presencia de cristales de fosfato de magnesio-amonio se asoció con la presencia de infección del tracto urinario y con Proteus mirabilis. Hubo una asociación significativa (p = 0,001) entre el uso de antibióticos profilácticos versus urocultivo >105 UFC/mL. Conclusión: Los análisis contribuyeron a la práctica clínica, ya que refuerzan el desarrollo de estrategias efectivas y monitoreadas sobre cultivos y prevención de la infección del tracto urinario asociada a los catéteres urinarios permanentes.


RESUMO Objetivo: Analisar a parte microbiológica e microestrutural dos cateteres vesicais de demora e sua associação com a prevenção de infecção do trato urinário. Método: Transversal, entre junho e dezembro de 2020, em que foram coletadas 42 pontas cateteres vesicais de demora e amostras de urina estéril para análise de cristais em microscopia óptica e de biofilmes em microscopia eletrônica de varredura. Fez-se analise de cultura e especificação do tipo de bactérias. Resultados: Verificou-se que 35,71% das amostras apresentaram o biofilme maduro aderido à ponta do cateter. Destacaram-se biofilmes de Proteus mirabilis, Enterococcus faecalis, Staphylococcus epidermidis, Enterococcus faecium e Enterobacter cloacae. A presença do cristal magnésio-amônio-fosfato foi associada à presença de infecção do trato urinário e ao Proteus mirabilis. Verificou-se associação significativa (p = 0,001) entre o uso de antibiótico profilático versus a urocultura >105 UFC/mL. Conclusão: As análises contribuíram para a prática clínica, pois reforçam a elaboração de estratégias efetivas e monitoradas sobre culturas e prevenção de infecção do trato urinário associada ao cateter vesical de demora.


Assuntos
Infecções Urinárias , Cateteres Urinários , Microscopia Eletrônica de Varredura , Saúde Pública , Vigilância em Saúde Pública
14.
Braz. oral res. (Online) ; 36: e115, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1403967

RESUMO

Abstract This study evaluate shaping ability of heat-treated NiTi-alloy instruments associated with different final irrigation protocols in flattened root canals. Thirty human mandibular incisors with flattened root canals were divided into 5 groups (n = 10): (XP) Original Protocol XP-endo Shaper; (XP-WT) Original Protocol XP-endo Shaper with working time variation; (XP-K) XP-endo Shaper with kinematics variation; (XP-WTK) XP-endo Shaper with kinematics and working time variations; (Hyflex) Hyflex CM. For the variation in working time protocols the same sample of the XP-endo Shaper groups with and without kinematic variation were used. To evaluate final irrigation protocols, groups 1, 3 and 5 were submitted to 3 protocols: (NI) No irrigation (n = 2); (CI) conventional irrigation (n = 4), and (EndoVac) irrigation (n = 4). The samples were scanned by microcomputed tomography and prepared for scanning electron microscopy evaluation. Quantitative data were evaluated using the parametric ANOVA test, with statistical significance level set at 5%, and qualitative data obtained were compared to establish the agreement between examiners through the Kappa test. It was observed that in the analysis of XP-endo Shaper protocols, the additional working time did not cause difference in any of parameters evaluated (p > 0.05) in relation to time recommended by manufacturer. Compared to Hyflex, XP-K showed highest mean volume increase (p < 0.05) and lowest percentage of untouched walls (p < 0.05). In the qualitative evaluation, final irrigation protocol with EndoVac provided the best cleaning results when associated with XP-K and with Hyflex. Thus, supplementary techniques are effective tools to enhance cleaning and to promote higher touch of walls during root canal preparation.

15.
An. bras. dermatol ; An. bras. dermatol;96(6): 730-734, Nov.-Dec. 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1355621

RESUMO

Abstract Lipoid proteinosis is a rare autosomal recessive disease, characterized by hyaline deposits of PAS-positive material in tissues due to mutations in the ECM1 gene. This study evaluated the ultrastructure of the skin of a 6-year-old child affected by this condition. The light microscopy identified PAS-positive hyaline deposits, which were more intense in the papillary dermis. Scanning electron microscopy of the dermis showed a compact papillary dermis and fibrillar deposits in the middle dermis. Transmission electron microscopy clearly showed the deposition of fibrillar material in the dermis, forming clusters adherent to elastic fibers, between the collagen bundles and the collagen fibers, and also filling up the cytoplasm of dermal fibroblasts.


Assuntos
Humanos , Criança , Proteinose Lipoide de Urbach e Wiethe , Pele , Proteínas da Matriz Extracelular , Colágeno , Hialina , Microscopia
16.
Braz. j. oral sci ; 20: e214873, jan.-dez. 2021. ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1254742

RESUMO

Aim: To compare the marginal fit of lithium disilicate CAD/CAM crowns and heat-pressed crowns fabricated using milled wax patterns, and evaluate its effect on stress distribution in implantsupported rehabilitation. Methods: A CAD model of a mandibular first molar was designed, and 16 lithium disilicate crowns (8/group) were obtained. The crown-prosthetic abutment set was evaluated in a scanning electron microscopy. The mean misfit for each group was recorded and evaluated using Student's t-test. For in silico analysis, a virtual cement thickness was designed for the two misfit values found previously, and the CAD model was assembled on an implant-abutment set. A load of 100 N was applied at 30° on the central fossa, and the equivalent stress was calculated for the crown, titanium components, bone, and resin cement layer. Results: The CAD/CAM group presented a significantly (p=0.0068) higher misfit (64.99±18.73 µm) than the heat-pressed group (37.64±15.66 µm). In silico results showed that the heat-pressed group presented a decrease in stress concentration of 61% in the crown and 21% in the cement. In addition, a decrease of 14.5% and an increase of 7.8% in the stress for the prosthetic abutment and implant, respectively, was recorded. For the cortical and cancellous bone, a slight increase in stress occurred with an increase in the cement layer thickness of 5.9% and 5.7%, respectively. Conclusion: The milling of wax patterns for subsequent inclusion and obtaining heat-pressed crowns is an option to obtain restorations with an excellent marginal fit and better stress distribution throughout the implant-abutment set


Assuntos
Microscopia Eletrônica de Varredura , Desenho Assistido por Computador , Adaptação Marginal Dentária , Prótese Dentária Fixada por Implante , Análise de Elementos Finitos , Materiais Dentários
17.
Autops Case Rep ; 11: e2021328, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34604122

RESUMO

BACKGROUND: Acute tubulointerstitial nephritis (ATIN) is a very rare paraneoplastic manifestation in patients with multiple myeloma (MM). It is an uncommon pattern of renal disease in such patients. CASE PRESENTATION: We report a case of an 82-year-old male who was admitted with acute kidney injury. Renal biopsy showed typical findings of light chain-associated ATIN with scattered inflammatory cells in the interstitium and associated active tubulitis. No other common manifestations of MM were present at the time of presentation, including hypercalcemia, hyperuricemia, proteinuria, bone pain or lytic bone lesions. Subsequent immunoassays revealed significant serum lambda light chain burden and Bence Jones protein in urine. Immunofluorescence demonstrated linear tubular basement membranes with positive staining for lambda light chain (3+). Electron microscopy (EM) further showed interstitial edema and inflammation. All the aforementioned findings are consistent with ATIN and supported the diagnosis of MM. CONCLUSIONS: In conclusion, light chain-associated ATIN should be considered in the differential diagnosis of acute interstitial nephritis. Henceforth, serum free light chains as well as serum and urine protein electrophoresis should be included in the workup of such patients.

18.
An Bras Dermatol ; 96(6): 730-734, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34544637

RESUMO

Lipoid proteinosis is a rare autosomal recessive disease, characterized by hyaline deposits of PAS-positive material in tissues due to mutations in the ECM1 gene. This study evaluated the ultrastructure of the skin of a 6-year-old child affected by this condition. The light microscopy identified PAS-positive hyaline deposits, which were more intense in the papillary dermis. Scanning electron microscopy of the dermis showed a compact papillary dermis and fibrillar deposits in the middle dermis. Transmission electron microscopy clearly showed the deposition of fibrillar material in the dermis, forming clusters adherent to elastic fibers, between the collagen bundles and the collagen fibers, and also filling up the cytoplasm of dermal fibroblasts.


Assuntos
Proteinose Lipoide de Urbach e Wiethe , Criança , Colágeno , Proteínas da Matriz Extracelular , Humanos , Hialina , Microscopia , Pele
19.
An. bras. dermatol ; An. bras. dermatol;96(3): 328-331, May-June 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1285053

RESUMO

Abstract Cutis rhomboidalis nuchae was assessed in a 65-year-old patient. Optical microscopy showed basophilic agglomerations in the reticular dermis with decreased elastic fibers. Trans- mission electron microscopy showed elongated, curved and fragmented structures, and in their interior the presence of electron-dense lumps was reduced and irregular, similar to modified elastic fibers, whereas the collagen fibers had a normal aspect. Scanning electron microscopy showed deposits between the bundles of collagen, resembling pebbles or stones. These findings demonstrate that, at one stage of the disease, the collagen remains normal and the alterations are seen in the elastic tissue.


Assuntos
Humanos , Idoso , Dermatopatias , Microscopia Eletrônica de Varredura , Derme , Microscopia Eletrônica de Transmissão , Tecido Elástico
20.
An Bras Dermatol ; 96(3): 328-331, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33775482

RESUMO

Cutis rhomboidalis nuchae was assessed in a 65-year-old patient. Optical microscopy showed basophilic agglomerations in the reticular dermis with decreased elastic fibers. Transmission electron microscopy showed elongated, curved and fragmented structures, and in their interior the presence of electron-dense lumps was reduced and irregular, similar to modified elastic fibers, whereas the collagen fibers had a normal aspect. Scanning electron microscopy showed deposits between the bundles of collagen, resembling pebbles or stones. These findings demonstrate that, at one stage of the disease, the collagen remains normal and the alterations are seen in the elastic tissue.


Assuntos
Dermatopatias , Idoso , Derme , Tecido Elástico , Humanos , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão