1.
Forensic Toxicol ; 42(1): 18-30, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37505359

RESUMO

PURPOSE: We developed and validated a method for quantitative analysis of ten synthetic cathinones in oral fluid (OF) samples, using microextraction by packed sorbent (MEPS) for sample preparation followed by liquid chromatography‒tandem mass spectrometry (LC‒MS/MS). METHOD: OF samples were collected with a Quantisal™ device and 200 µL was extracted using a C18 MEPS cartridge installed on a semi-automated pipette and then analyzed using LC‒M/SMS. RESULTS: Linearity was achieved between 0.1 and 25 ng/mL, with a limit of detection (LOD) of 0.05 ng/mL and a limit of quantification (LOQ) of 0.1 ng/mL. Imprecision (% relative standard deviation) and bias (%) were better than 11.6% and 7.5%, respectively. The method had good specificity and selectivity against 9 different blank OF samples (from different donors) and 68 pharmaceutical and drugs of abuse with concentrations varying between 400 and 10,000 ng/mL. No evidence of carryover was observed. The analytes were stable after three freeze/thaw cycles and when kept in the autosampler (10 °C) for up to 24 h. The method was successfully applied to quantify 41 authentic positive samples. Methylone (mean 0.6 ng/mL, median 0.2 ng/mL), N-ethylpentylone (mean 16.7 ng/mL, median 0.35 ng/mL), eutylone (mean 39.1 ng/mL, median 3.6 ng/mL), mephedrone (mean 0.5 ng/mL, median 0.5 ng/mL), and 4-chloroethcathinone (8.1 ng/mL) were quantified in these samples. CONCLUSION: MEPS was an efficient technique for Green Analytical Toxicology purposes, which required only 650 µL organic solvent and 200 µL sodium hydroxide, and the BIN cartridge had a lifespan of 100 sample extractions.


Assuntos
Catinona Sintética , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Microextração em Fase Sólida/métodos , Limite de Detecção
2.
Anal Bioanal Chem ; 414(1): 413-423, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33763748

RESUMO

This paper describes the synthesis, characterization, and use of ionic liquids supported on silica, functionalized with graphene oxide through covalent bonding (ILz/Si@GO), as sorbents for microextraction by packed sorbent (MEPS). Seven selected pesticides (diazinon, heptachlor, aldrin, endrin, dieldrin, endosulfan, and methoxychlor), used for the prevention of pests in coffee crops, and endosulfan sulfate-an endosulfan metabolite-were selected for this study as model compounds for evaluating the sorbent performance of the synthesized materials in the MEPS device. The cycles of each of the stages were previously optimized through univariate experiments to carry out the extraction. The ILz/Si@GO phase was compared to other sorbents used in MEPS (GO, DVB-MMA, C4/SiO2, C8/SiO2, ILz/SiO2, and bare silica) and also with graphene functionalized through other methodologies, where ILz/Si@GO showed the best results. The material was characterized using a range of techniques. The selectivity of the sorbent material and its adsorption capacity were evaluated by gas chromatography coupled with tandem mass spectrometry. The precision and accuracy of the method showed a relative standard deviation lower than 10% and recoveries from 35 to 97%. Finally, the proposed method was employed for the determination of pesticide residues in coffee samples.


Assuntos
Grafite , Líquidos Iônicos , Praguicidas , Café , Cromatografia Gasosa-Espectrometria de Massas , Grafite/química , Líquidos Iônicos/análise , Limite de Detecção , Praguicidas/análise , Dióxido de Silício/química , Microextração em Fase Sólida/métodos
3.
Talanta ; 219: 121185, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32887103

RESUMO

An original, selective and automated method, for the microextraction by packed sorbent (MEPS) of Δ9-tetrahydrocannabinol (THC), 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH), and 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) from human urine, was developed by using (i) a catechin-molded molecularly imprinted polymer (MIP), (ii) a new lab-made MEPS device easily repackable with any commercial or lab-made sorbent, and (iii) a lab-made multi syringe autosampler. Analyses were performed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the developed method proved to be precise, accurate and showed good linearity. Determination coefficients ranged from 0.96 to 0.99, in the range of 5-250 ng mL-1. Limits of detection and quantification ranged between 1.0 and 5.0 ng mL-1 and 5.0 and 20.0 ng mL-1. The method was successfully applied in the analysis of real urine samples. The same packed syringe was effectively used over 90 consecutive extractions without carry-over effects.


Assuntos
Canabinoides , Polímeros Molecularmente Impressos , Canabinoides/análise , Cromatografia Líquida , Humanos , Limite de Detecção , Espectrometria de Massas em Tandem
4.
J Chromatogr A ; 1487: 64-71, 2017 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-28143664

RESUMO

This paper describes the synthesis, characterization and use of graphene supported on aminopropyl silica through covalent bonds (Si-G) as a sorbent for microextraction by packed sorbent (MEPS). Five parabens (methyl, ethyl, propyl, butyl and benzyl) present in water matrices were used as model compounds for this evaluation. The Si-G phase was compared to other sorbents used in MEPS (C18 and Strata™-X) and also with graphene supported on primary-secondary amine (PSA) silica, where Si-G showed better results. After this, the MEPS experimental parameters were optimized using the Si-G sorbent. The following variables were optimized through univariate experiments: pH (4,7 and 10), desorption solvent (ACN:MeOH (50:50), ACN:H2O (40:60), MeOH and ACN) and ionic strength (0, 10 and 20% of NaCl). A factorial design 26-2 was then employed to evaluate other variables, such as the sample volume, desorption volume, sampling cycles, wash cycles and desorption cycles, as well as the influence of NaCl% on the extraction performance. The optimized method achieved a linear range of 0.2-20µg/L for most parabens; weighted calibration models were employed during the linearity evaluation to reduce the absolute sum of the residue values and improve R2, which ranged from 0.9753 to 0.9849. The method's accuracy was 82.3-119.2%; precision, evaluated as the coefficient of variance for intraday and interday analysis, ranged from 1.5 to 19.2%. After evaluation of the figures of merit, the method was applied to the determination of parabens in water samples.


Assuntos
Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Parabenos/isolamento & purificação , Dióxido de Silício/química , Microextração em Fase Sólida/instrumentação , Grafite/química , Parabenos/análise , Sensibilidade e Especificidade , Solventes/química , Água/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação