Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
RFO UPF ; 19(1): 48-56, abr. 2014.
Artigo em Português | LILACS-Express | LILACS | ID: lil-726459

RESUMO

As ligas de NiTi são amplamente utilizadas em disposi-tivos da área odontológica, como na Implantodontia, devido as suas propriedades de biocompatibilidade, memória de forma e superelasticidade. Objetivo: Ava-liar a bioatividade e as características morfológicas de liga de NiTi (45,3% de Ni e 54,7% de Ti), tratadas a laser com e sem recobrimento de apatita. Materiais e método: As ligas de NiTi foram obtidas pela técnica Plasma Skull Push Pull, tratadas superficialmente. As amostras foram tratadas a laser (Yb:YAG) e pelo método biomimético em SBF-0 e SBF-6 (Simulated Body Fluid), ambas a 1,5M. A análise de bioatividade foi realizada por meio da pesagem, espectroscopia por energia dis-persiva de raios X (EDS) e microscopia eletrônica de varredura (MEV). Resultados: As espectroscopias reve-laram aumento na concentração de oxigênio e carbono após a ablação, favorecendo a difusão de átomos de oxigênio e formação de óxidos de titânio. Após a de-posição da apatita pelo método biomimético em SBF-0 e 6, o recobrimento apresentou uma razão molar de Ca/P de aproximadamente 1,0, caracterizando a forma-ção de apatitas de baixa cristalinidade. Conclusão: A associação da irradiação a laser e deposição química de apatitas pelo método biomimético em SBF-6, embo-ra tenha demonstrado um melhor desempenho quanto à bioatividade e topografia das ligas, o ganho de massa não foi estatisticamente significativo ao nível de 5%. Tais propriedades podem contribuir para maior inte-ração do biomaterial com o meio biológico e possível redução no tempo de osseointegração.

2.
RFO UPF ; 16(2)maio-ago. 2011.
Artigo em Português | LILACS | ID: lil-611994

RESUMO

Objetivo: O objetivo deste trabalho foi avaliar a melhora nutricional e a qualidade de vida dos pacientes reabilitados com implantes. Metodologia: Participaram deste estudo 19 indivíduos dos gêneros feminino e masculino, com idade entre 31 e 81 anos, reabilitados por próteses sobre implante. Para a coleta dos dados utilizou-se o questionário MNA- Mini Nutritional Assessment®, focalizando questões relativas à nutrição. Resultados: Ante-riormente aos implantes, 26,3% dos pacientes referiram diminuição na ingesta de alimentos em virtude de dificuldades de mastigação e deglutição, perda do apetite ou problemas digestivos. Esse percentual foi pratica-mente abolido após a reabilitação por implantes, o qual ficou em 5,3%. O teste exato de Fisher foi sugestivo de significância (p = 0,089), entretanto não houve diferença significativa no número de refeições, na frequência de ingestão adequada de leite, legumes e carnes, con-sumo de vegetais e frutas e na ingesta de água antes e depois da instalação das próteses sobre implante. Conclusão: Conclui-se que os pacientes apresentaram uma melhora na sua capacidade mastigatória, porém não alteraram seus hábitos alimentares.

3.
Rev. odontol. Univ. Cid. Sao Paulo ; 22(2): 122-133, maio-ago. 2010. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-563878

RESUMO

Introdução: O objetivo deste estudo é avaliar in vitro a transmissão de forças do sistema de retenção do tipo barra-clipe para overdenture, quando duas posições de implantes são simuladas, utilizando-se para isso as técnicas da análise fotoelástica. Métodos: Assim, duas mandíbulas fotoelásticas foram confeccionadas com dois implantes, posicionados na região interforaminal a 22mm de distância: modelo 1 - AFIP, modelo fotoelástico com implantes paralelos e orientados verticalmente; e modelo 2 - AFII, modelo fotoelástico com implantes angulados 10º em relação à linha média da mandíbula. Sobre os implantes foram instalados o sistema de retenção barra-clipe e uma prótese overdenture. Para simulação da mucosa oral, foi interposta, entre a prótese overdenture e a mandíbula fotoelástica, uma camada de 2mm de silicone. Cargas de 0,5; 1,0; 1,5; 2,0; e 3 bars foram aplicadas e as imagens analisadas. Resultados: Os resultados mostraram que não houve semelhança nas áreas de tensão entre os modelos de resina fotoelástica, quando avaliada a angulação dos implantes. Já o modelo1 AFIP apresentou maior concentração no ápice dos implantes e o modelo 2 AFII apresentou maior concentração na face mesial dos implantes. Conclusão: Considerando-se as limitações deste trabalho, concluiu-se que o método de análise fotoelástica é de grande valia para a obtenção de informação em relação à biomecânica referente a esse tipo de prótese e sistema de retenção.


Introduction: The main objective of this study is to appraise in vitro the load transmission in bar-clip retention system for overdenture when 2 implant position are simulated, using for this purpose the photoelastic analysis technique. Methods: Therefore, 2 photoelastic mandibles were manufactured with 2 implants each one, positioned in interforaminal region within 22 mm of distance: model 1 AFIP, photoelastic model with parallel and vertically oriented implants; and model 2 û AFII, photoelastic model with 10º angled implants in relation to mandible midline. A bar-clip retention system and an overdenture were fixed over both implants. To simulate oral mucosa were added a 2 mm silicon layer between overdenture prosthesis and photoelastic mandible. 0.5; 1.0; 1.5; 2.0 and 3.0 bars loads were applied and correspondent images were analyzed. Results: Results evidenced that: there is no similarity in loaded areas between photoelastic resin models, when the implant angle is appraised. Since in the model 1 - AFIP, the concentration area of tension was at implant apex and in the model 2 û AFII was at the distal face. Conclusion: Considering the limitations of this study, it was concluded that photoelastic analysis has a high potential value for obtaining information concerning the biomechanics of this kind of prosthesis and retention system.


Assuntos
Implantação Dentária Endóssea , Implantação Dentária Endo-Óssea Endodôntica , Mandíbula/fisiologia
4.
Innov. implant. j., biomater. esthet. (Impr.) ; 4(2): 26-30, maio-ago. 2009. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-561081

RESUMO

O objetivo deste estudo foi avaliar a fixação biomecânica de superfície de implante tratada com biocerâmica absorvível e ataque ácido (NanossTM - experimento) comparando com uma superfície tratada por duplo ataque ácido (controle) em cães. Métodos: o modelo animal compreendeu a instalação de 24 implantes na porção proximal da tíbia de 6 cães (12 por superfície, 2 por membro), que permaneceram por 2 e 4 semanas de experimentação in vivo. Após a eutanásia os espécimes foram destinados ao teste biomecânico (torque para fratura interfacial). ANOVA com 95% de intervalo de confiança e o teste Tukey para comparações múltiplas foram utilizados. Foi encontrada diferença significativa nos valores do teste biomecânico entre os grupos NanossTM (p < 0,03) e controle. Conclusão: de acordo com o teste biomecânico, os períodos iniciais da osseointegração foram afetados positivamente pela superfície NanossTM, quando comparados ao grupo controle.


The objective of this study was to analyses the biomechanical fixation of a bioceramic grit-blasted and acid-etched surface (NanossTM, test), versus a dual acid-etched implant surface (control) in a dog model. Methods: the animal model comprised the placement of 24 implants along the proximal tibiae of 6 dogs (12 per surface, 2 per limb), which remained for 2 and 4 weeks implantation time. After euthanization specimens were biomechanically tested (torque to facial fracture). ANOVA at 95% level of confidence and Tukey post-hoc test was utilized for multiple comparisons. Results: Significantly higher removal torque was observed for the NanossTM group compared to control one (p < 0.03). Conclusion: according to the biomechanical results, early biomechanical fixation was positively affected by the NanossTM surface compared to the dual-acid etched surface.


Assuntos
Cães , Fenômenos Biomecânicos , Implantes Dentários , Osseointegração
5.
Innov. implant. j., biomater. esthet. (Impr.) ; 4(1): 69-74, jan.-abr. 2009. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-561076

RESUMO

O tratamento de pacientes com anomalias, traumas e defeitos decorrentes da ressecção de tecidos acometidos por processo tumoral são considerados verdadeiros desafios para as equipes de reabilitação oral. Dentre as possibilidades de enxerto para o tratamento de defeitos ósseos em mandíbula, estão os enxertos de crista ilíaca, escápula, osso radial do antebraço e de fíbula. O enxerto de fíbula vem sendo utilizado na reconstrução de mandíbula devido às suas características favoráveis como volume ósseo e espessura de cortical. A instalação de implantes dentais nos enxertos de fíbula, assim como as próteses instaladas sobre os mesmos, vêm sendo realizadas com sucesso. Este relato de caso clínico descreve a reabilitação oral de paciente submetido a transplante autógeno de fíbula, devido à ressecção parcial de mandíbula para remoção de um tumor, diagnosticado como sarcoma indiferenciado. Foram instalados 5 implantes dentais (SIN - Sistema de Implante, São Paulo, SP, Brasil) na mandíbula e confeccionada prótese implantossuportada, propiciando restabelecimento da função mastigatória e recuperação da qualidade de vida do paciente.


The treatment of patients compromised in with anomalies, trauma, and defects due to the resection of cancerous tissues considerably challenges restorative dental teams. Among the possibilities of grafts to the treatment of mandibular bone defects, the iliac flap , the scapula flap, the radial forearm flap and the fibula flap are available. Fibular bone graft has being used in the mandibular reconstructions due its favorable conditions, such as volume and width of its cortical bone. Dental implants placement in fibula grafts and subsequent implant-supported prosthetic rehabilitation have been successfully used. This case report describes the oral rehabilitation of patient subimitted to reconstruction with autogenous fibular graft, following ablation for tumor (undifferentiated sarcoma), and partial mandibular resection. Five dental implants (SIN - Sistema de Implante, São Paulo, SP, Brazil) were placed in mandibular bone, reestablishing chewing function and recovering the patient’s quality of life.


Assuntos
Masculino , Adulto , Pessoa de Meia-Idade , Implantes Dentários/métodos , Mandíbula/anormalidades , Sarcoma , Prótese Dentária Fixada por Implante
6.
Araçatuba; s.n; 2009. 110 p. ilus.
Tese em Português | BBO - Odontologia | ID: biblio-865257

RESUMO

Os aspectos biomecânicos do implante osseointegrado são fundamentalmente diferentes daqueles do dente natural, que é circundado pelo ligamento periodontal. A possibilidade de transferência de sobrecarga ao implante, e deste ao osso, pode exceder o limite fisiológico e provocar falha da reabilitação ou até mesmo a perda da osseointegração. Portanto, é essencial otimizar a distribuição da carga mastigatória através das próteses e destas para os implantes e osso suporte. A avaliação biomecânica da geometria do implante e do sistema de retenção protético torna-se fundamental, visto que os implantes foram desenvolvidos para suportarem forças durante sua função. O estudo das tensões entre as estruturas de suporte e implantes tem sido realizado para prevenir falhas da estrutura protética ou do próprio implante. Assim, nosso trabalho teve como objetivo a realização de dois capítulos, sendo que o primeiro capítulo analisa a distribuição das tensões nos diferentes tipos de implantes, hexágono externo, hexágono interno e cone-morse, em relação aos sistemas de retenção protética, parafusadas ou cimentadas, em próteses parciais fixas implantossuportadas de três elementos. O segundo capítulo aborda a distribuição de tensões nas próteses parciais fixas implantossuportadas unitárias e de três elementos, usando implantes de hexágono externo, interno e cone-morse. Foram construídos modelos fotoelásticos em resina PL-2 (Vishay Measurements Group, Inc Raleigh, N.C. USA), com implantes de 4,00 x 10 mm (Conexão Sistema de Prótese Ltda- São Paulo- SP - Brasil). A saber foram construídos para: 1) próteses parciais fixas implantossuportadas de três elementos com dois implantes, situados na região segundo pré-molar e segundo molar, e 2) modelos com implantes unitários. As próteses foram construídas de forma padronizada e em liga de Ni-Cr (Fit Cast –SB Plus -sem Berílio, Talladium do Brasil, Curitiba- PR-Brasil). Foi utilizado um polariscópio circular e aplicado cargas axial e oblíqua...


The biomechanical aspects of an implant are fundamentally different from those of a natural tooth, which is surrounded by a periodontal ligament. The possibility of transferring the overload to the implant, and then to the bone, may exceed the physiological limit and cause failure of rehabilitation or even loss of osseointegration. Therefore, it is essential to optimize the distribution of the chewing load through the prostheses and from them to the implants and support bone. The biomechanical evaluation of the implant’s geometry and prosthetic retained system becomes essential, since the implants were developed to withstand forces during their function. The study of the stress between the structures of support and implants have been done to prevent failures of the prosthesis structure or of the implant. Thus, our work aimed at the achievement of two studies, being the first chapter the analysis of stress distribution on different types of implants: external hexagon, internal hexagon and morse taper, compared to retained prosthesis systems: screwed and cemented in 3-FDP. The second chapter discusses the distribution of stress between dental implant single tooth and 3-FDP, taking into account the different types of connection of the implant. Photoelastic models were built in PL-2 resin (Vishay Measurements Group, Inc Raleigh, NC USA) with 4.00 x 10 mm implants (Conexao Sistema de Protese Ltda- Sao Paulo- SP - Brazil). Models were built for: 1.) fixed partial dentures of three elements with two implants, located in the second pre-molar and on the region of the second molar, and 2) models with dental implants single tooth. The prostheses were constructed in a standardized way with Ni-Cr alloy (Fit Cast-SB Plus - without Beryllium, Talladium do Brasil, Curitiba-PR-Brazil). A circular polariscopy was used and a Universal Testing Machine (EMIC DL-3000) applied axial and oblique loads of 100N in a 45o angle. The stress was analyzed from a qualitative point of view...


Assuntos
Prótese Dentária Fixada por Implante , Prótese Parcial Fixa , Implantes Dentários
7.
Araraquara; s.n; 2009. 134 p. ilus, tab.
Tese em Português | BBO - Odontologia, LILACS | ID: biblio-865420

RESUMO

A proposta deste estudo in vitro foi avaliar 3 técnicas de moldagem (Cônico, Hélice e Unido com barra) para próteses implantossuportadas. Materiais e métodos: Um modelo mandibular em latão contendo 4 análogos de implantes e uma estrutura metálica foram confeccionados. Foram utilizados 2 materiais de moldagem: Silicona de polimerização por adição (Express STD, 3M ESPE) e Silicona de polimerização por condensação (Zetaplus/Oranwash, Zermack). Seis grupos foram formados pela combinação entre cada material e técnica de moldagem. Um total de 30 modelos foram fabricados (5 modelos por grupo) e 120 valores de fendas foram analisados (1 valor de fenda para cada análogo de implante). Resultados: Para o material Express, os valores médios de fenda foram: 164,40 μm (Cônico), 97,90 μm (Hélice) e 127,79 μm (Unido). Para o material Zetaplus/Oranwash, os valores médios de fenda foram: 219,37 μm (Cônico), 118,57 μm (Hélice) e 78,50 μm (Unido). Houve uma diferença estatística significante entre o Cônico e a Hélice para o material Express (p<.05). Quando o material avaliado foi o Zetaplus/Oranwash, todos os grupos foram diferentes estatisticamente entre si (p<.05). Conclusões: Os melhores resultados foram alcançados para a Hélice e para Unido quando o material avaliado foi o Express. Para o Zetaplus/Oranwash, a melhor técnica foi o Unido, seguida da Hélice e do Cônico.


The purpose of this in vitro study was to evaluate 3 impression techniques (tapered impression copings, squared modified impression copings, and squared impression copings splinted with bur and acrylic resin) for implant-supported prosthesis. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutments analogs and a framework were fabricated. Addition silicone – Express – and condensation silicone – Zetaplus/Oranwash - impression materials were tested. Six groups were formed by combining each material and impression technique. Five casts were made per group for a total of 30 casts and 120 gap values (1 gap value for each implant-abutment analog). Results: With the Express impression material, the mean gap values were 164.40 μm for the tapered group, 97.90 μm for squared modified group and 127.79 μm for squared splinted group. With the Zetaplus/Oranwash impression materials, the mean gap values were 219.37 μm for the tapered group, 118.57 μm for squared modified group and 78.50 μm for squared splinted group. There was significantly difference between tapered impression technique and squared modified impression technique (P<.05), when the material was Express. When the material was the condensation silicone, all groups had significantly difference among themselves (P<.05). Conclusions: The best results were achieved for squared modified impression technique and squared splinted impression techniques, when the impression material was Express. For condensation silicone, the best technique was squared splinted group, followed by squared modified group, and tapered group.


Assuntos
Técnicas In Vitro , Técnica de Moldagem Odontológica , Implantes Dentários , Materiais para Moldagem Odontológica , Reabilitação Bucal
8.
Araçatuba; s.n; 2008. 144 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-865239

RESUMO

O objetivo deste trabalho foi analisar o reparo ósseo peri-implantar de implantes instalados sobre raízes dentárias reimplantadas tardiamente, apresentando processo de anquilose e reabsorção por substituição. Foram utilizados os terceiros e quartos pré-molares inferiores de 4 cães machos (Beagle). Os dentes foram seccionados, e as raízes mesiais extraídas e mantidas durante 1 hora em temperatura ambiente. Após a remoção do ligamento periodontal necrótico e tratamento endodôntico, imergiram-se em fluoreto de sódio por 5 minutos e reimplantou a porção no alvéolo esplintando nas porções distais. Nestas foram realizadas pulpotomia e restauração. Decorridos 30 dias, as porções mesiais tiveram suas coroas seccionadas. Após 5 meses, cinco implantes foram instalados em osso reparado, grupo I, (Controle); nove foram instalados nos alvéolos frescos pós-exodônticos das porções distais (Grupo II – Imediato) e doze implantes foram instalados sobre as raízes mesiais em processo de reabsorção radicular externa (Grupo III – experimental). Decorridos 120 dias, os resultados foram analisados pelo contato osso implante da superfície do implante sem roscas e das três primeiras roscas. Foi avaliada, também, a área de tecido ósseo presente nos espaços internos das três primeiras roscas e da área espelho correspondente. O contato osso implante foi de 55% no grupo controle, 48% no imediato e 40% no grupo experimental. A área de tecido ósseo foi, respectivamente, 71%, 61% e 55%, e a área espelho de tecido ósseo foi de 62%, 60% e 58%. Conclui-se que o reparo ósseo perimplantar de implantes instalados sobre raízes apresentou um pequeno em relação aos outros dois grupos


The purpose of this study was to analyze the peri-implant bone repair of dental implants placed on delayed reimplated roots, with process of ankylosis and reabsorption by substitution. The lower third and fourth pre-molar of four male dogs (Beagle) was used. The teeth were cut, and the mesial roots were extracted and kept out for 1 hour at ambient temperature. After removal of necrotic periodontal ligament and endodontic treatment, the root was immersed in sodium fluoride for 5 minutes. Then it was reimplanted in the correspondent alveolar bone and splinted in distal portion. A pulpotomy and a crown restoration were conducted on the distal portion. After 30 days, the mesial portions had their crowns cut (decoronation).Moreover, 5 months later, five implants were installed in bone repair, Group I (Control), and nine were installed in the fresh socket of the distal portions, which were extracted (Group II - Immediate). Finally, twelve implants were installed on the mesial roots, with process of external resorption (Group III - experimental). After 120 days, the results were analyzed by bone implant contact, from the surface of the implant without threads to the first three threads. It was also evaluated the area of the bone tissue located in the internal spaces of the first three threads and the corresponding mirror area. The bone implant contact was 55% in the control group, 48% in the immediate group and 40% in the experimental group. The area of bone tissue in the internal threads area was respectively 71%, 61% and 55%, and the mirror area of bone tissue had the following results: 62%, 60% and 58%. It was concluded that peri-implant bone repair of the implant put on the roots with an external resorption showed delay compared to the other two groups


Assuntos
Animais , Masculino , Cães , Anquilose Dental , Reimplante
9.
Araçatuba; s.n; 2008. 144 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-563702

RESUMO

O objetivo deste trabalho foi analisar o reparo ósseo peri-implantar de implantes instalados sobre raízes dentárias reimplantadas tardiamente, apresentando processo de anquilose e reabsorção por substituição. Foram utilizados os terceiros e quartos pré-molares inferiores de 4 cães machos (Beagle). Os dentes foram seccionados, e as raízes mesiais extraídas e mantidas durante 1 hora em temperatura ambiente. Após a remoção do ligamento periodontal necrótico e tratamento endodôntico, imergiram-se em fluoreto de sódio por 5 minutos e reimplantou a porção no alvéolo esplintando nas porções distais. Nestas foram realizadas pulpotomia e restauração. Decorridos 30 dias, as porções mesiais tiveram suas coroas seccionadas. Após 5 meses, cinco implantes foram instalados em osso reparado, grupo I, (Controle); nove foram instalados nos alvéolos frescos pós-exodônticos das porções distais (Grupo II – Imediato) e doze implantes foram instalados sobre as raízes mesiais em processo de reabsorção radicular externa (Grupo III – experimental). Decorridos 120 dias, os resultados foram analisados pelo contato osso implante da superfície do implante sem roscas e das três primeiras roscas. Foi avaliada, também, a área de tecido ósseo presente nos espaços internos das três primeiras roscas e da área espelho correspondente. O contato osso implante foi de 55% no grupo controle, 48% no imediato e 40% no grupo experimental. A área de tecido ósseo foi, respectivamente, 71%, 61% e 55%, e a área espelho de tecido ósseo foi de 62%, 60% e 58%. Conclui-se que o reparo ósseo perimplantar de implantes instalados sobre raízes apresentou um pequeno em relação aos outros dois grupos.


The purpose of this study was to analyze the peri-implant bone repair of dental implants placed on delayed reimplated roots, with process of ankylosis and reabsorption by substitution. The lower third and fourth pre-molar of four male dogs (Beagle) was used. The teeth were cut, and the mesial roots were extracted and kept out for 1 hour at ambient temperature. After removal of necrotic periodontal ligament and endodontic treatment, the root was immersed in sodium fluoride for 5 minutes. Then it was reimplanted in the correspondent alveolar bone and splinted in distal portion. A pulpotomy and a crown restoration were conducted on the distal portion. After 30 days, the mesial portions had their crowns cut (decoronation).Moreover, 5 months later, five implants were installed in bone repair, Group I (Control), and nine were installed in the fresh socket of the distal portions, which were extracted (Group II - Immediate). Finally, twelve implants were installed on the mesial roots, with process of external resorption (Group III - experimental). After 120 days, the results were analyzed by bone implant contact, from the surface of the implant without threads to the first three threads. It was also evaluated the area of the bone tissue located in the internal spaces of the first three threads and the corresponding mirror area. The bone implant contact was 55% in the control group, 48% in the immediate group and 40% in the experimental group. The area of bone tissue in the internal threads area was respectively 71%, 61% and 55%, and the mirror area of bone tissue had the following results: 62%, 60% and 58%. It was concluded that peri-implant bone repair of the implant put on the roots with an external resorption showed delay compared to the other two groups.


Assuntos
Animais , Masculino , Cães , Implantação Dentária Endóssea , Anquilose Dental , Reimplante
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA