RESUMO
It has been advocated that total hip arthroplasty (THA) is probably the most successful surgical intervention performed in Medicine. In the 1960s, Sir John Charnley not only introduced, but also modified and improved the technique of cemented arthroplasties. The concepts on biological fixation established by Pillar and Galante served as the foundation for the development of uncemented implants that are now used worldwide. Currently, THA is a worldwide widespread surgery performed on millions of people. However, keeping abreast of the large number of information available on these procedures, especially on implant fixation, designs, different tribological pairings, and the long-term results can be challenging at times. This article is a brief update on the main aspects of THA.
A artroplastia total do quadril (ATQ) é uma das cirurgias de maior sucesso na história da medicina. Nos anos 1960, Sir John Charnley introduziu e aperfeiçoou as artroplastias cimentadas. Pillar e Galante estabeleceram os conceitos da fixação biológica, base para o desenvolvimento das artroplastias não cimentadas. Atualmente, a ATQ é uma cirurgia mundialmente difundida e feita em milhões de pessoas. No entanto, o grande número de informações disponíveis sobre as artroplastias, especialmente quanto à forma de fixação do implante ao osso, aos diferentes designs das hastes e dos acetábulos, aos diferentes pares tribológicos e aos resultados no longo prazo por vezes dificulta a tomada de decisão. Este artigo é uma breve atualização sobre os principais aspectos da ATQ.
RESUMO
OBJECTIVE: To prove the accuracy of a customized guide developed according to our method. METHODS: This customized guide was developed from a three-dimensional model of proximal femur reconstructed using computed tomography data. Based on the new technique, the position of the guide pin insertion was selected and adjusted using the reference of the anatomical femoral neck axis. The customized guide consists of a hemispheric covering designed to fit the posterior part of the femoral neck. The performance of the customized guide was tested in eight patients scheduled for total hip arthroplasty. The stability of the customized guide was assessed by orthopedic surgeons. An intraoperative image intensifier was used to assess the accuracy. RESULTS: The customized guide was stabilized with full contact and was fixed in place in all patients. The mean angular deviations in relation to the what was planned in anteroposterior and lateral hip radiographs were 0.5º ± 1.8º in valgus and 1.0º ± 2.4º in retroversion, respectively. CONCLUSION: From this pilot test, the authors suggest that the proposed technique could be applied as a customized guide to the positioning device for hip resurfacing arthroplasty with acceptable accuracy and user-friendly interface. Level of Evidence IV, Cases Series.
OBJETIVO: Comprovar a precisão de uma guia personalizada desenvolvida a partir de nosso método. MÉTODOS: Esta guia personalizada foi desenvolvida a partir do modelo tridimensional da parte proximal do fêmur reconstruída usando dados de tomografia computadorizada. Com base na nova técnica, a posição de inserção do pino da guia foi selecionada e ajustada usando a referência do eixo anatômico do colo do fêmur. A guia personalizada consiste em um revestimento hemisférico projetado para encaixar na parte posterior do colo do fêmur. O desempenho da guia personalizada foi testado em oito pacientes que seriam submetidos à artroplastia total do quadril. A estabilidade da guia personalizada foi avaliada por cirurgiões ortopedistas. Para avaliar a precisão, usou-se um intensificador de imagem intraoperatório. RESULTADOS: A guia personalizada foi estabilizada com contato total e foi fixada em todos os pacientes. Os desvios angulares médios com relação ao planejado nas radiografias anteroposteriores e laterais do quadril foram de 0,5º ± 1,8º em valgo e 1,0º ± 2,4º em retroversão, respectivamente. CONCLUSÃO: A partir deste teste piloto, os autores sugerem que a técnica proposta poderia ser aplicada como guia personalizada para o dispositivo de posicionamento para resurfacing em artroplastia de quadril com aceitável precisão e interface amigável. Nível de Evidência IV, Série de Casos .
RESUMO
ABSTRACT Objective: To prove the accuracy of a customized guide developed according to our method. Methods: This customized guide was developed from a three-dimensional model of proximal femur reconstructed using computed tomography data. Based on the new technique, the position of the guide pin insertion was selected and adjusted using the reference of the anatomical femoral neck axis. The customized guide consists of a hemispheric covering designed to fit the posterior part of the femoral neck. The performance of the customized guide was tested in eight patients scheduled for total hip arthroplasty. The stability of the customized guide was assessed by orthopedic surgeons. An intraoperative image intensifier was used to assess the accuracy. Results: The customized guide was stabilized with full contact and was fixed in place in all patients. The mean angular deviations in relation to the what was planned in anteroposterior and lateral hip radiographs were 0.5º ± 1.8º in valgus and 1.0º ± 2.4º in retroversion, respectively. Conclusion: From this pilot test, the authors suggest that the proposed technique could be applied as a customized guide to the positioning device for hip resurfacing arthroplasty with acceptable accuracy and user-friendly interface. Level of Evidence IV, Cases Series.
RESUMO Objetivo: Comprovar a precisão de uma guia personalizada desenvolvida a partir de nosso método. Métodos: Esta guia personalizada foi desenvolvida a partir do modelo tridimensional da parte proximal do fêmur reconstruída usando dados de tomografia computadorizada. Com base na nova técnica, a posição de inserção do pino da guia foi selecionada e ajustada usando a referência do eixo anatômico do colo do fêmur. A guia personalizada consiste em um revestimento hemisférico projetado para encaixar na parte posterior do colo do fêmur. O desempenho da guia personalizada foi testado em oito pacientes que seriam submetidos à artroplastia total do quadril. A estabilidade da guia personalizada foi avaliada por cirurgiões ortopedistas. Para avaliar a precisão, usou-se um intensificador de imagem intraoperatório. Resultados: A guia personalizada foi estabilizada com contato total e foi fixada em todos os pacientes. Os desvios angulares médios com relação ao planejado nas radiografias anteroposteriores e laterais do quadril foram de 0,5º ± 1,8º em valgo e 1,0º ± 2,4º em retroversão, respectivamente. Conclusão: A partir deste teste piloto, os autores sugerem que a técnica proposta poderia ser aplicada como guia personalizada para o dispositivo de posicionamento para resurfacing em artroplastia de quadril com aceitável precisão e interface amigável. Nível de Evidência IV, Série de Casos .
RESUMO
ABSTRACT It has been advocated that total hip arthroplasty (THA) is probably the most successful surgical intervention performed in Medicine. In the 1960s, Sir John Charnley not only introduced, but also modified and improved the technique of cemented arthroplasties. The concepts on biological , fixation established by Pillar and Galante served as the foundation for the development of uncemented implants that are now used worldwide. Currently, THA is a worldwide widespread surgery performed on millions of people. However, keeping abreast of the large number of information available on these procedures, especially on implant fixation, designs, different tribological pairings, and the long-term results can be challenging at times. This article is a brief update on the main aspects of THA.
RESUMO A artroplastia total do quadril (ATQ) é uma das cirurgias de maior sucesso na história da medicina. Nos anos 1960,SirJohn Charnley introduziu e aperfeiçoou as artroplastias cimentadas. Pillar e Galante estabeleceram os conceitos da fixação biológica, base para o desenvolvimento das artroplastias não cimentadas. Atualmente, a ATQ é uma cirurgia mundialmente difundida e feita em milhões de pessoas. No entanto, o grande número de informações disponíveis sobre as artroplastias, especialmente quanto à forma de fixação do implante ao osso, aos diferentesdesignsdas hastes e dos acetábulos, aos diferentes pares tribológicos e aos resultados no longo prazo por vezes dificulta a tomada de decisão. Este artigo é uma breve atualização sobre os principais aspectos da ATQ.