Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 434
Filtrar
1.
Front Physiol ; 15: 1438089, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39129756

RESUMO

Background: The microgravity environment has a direct impact on the cardiovascular system due to the fluid shift and weightlessness that results in cardiac dysfunction, vascular remodeling, and altered Cardiovascular autonomic modulation (CAM), deconditioning and poor performance on space activities, ultimately endangering the health of astronauts. Objective: This study aimed to identify the acute and chronic effects of microgravity and Earth analogues on cardiovascular anatomy and function and CAM. Methods: CINAHL, Cochrane Library, Scopus, Science Direct, PubMed, and Web of Science databases were searched. Outcomes were grouped into cardiovascular anatomic, functional, and autonomic alterations, and vascular remodeling. Studies were categorized as Spaceflight (SF), Chronic Simulation (CS), or Acute Simulation (AS) based on the weightlessness conditions. Meta-analysis was performed for the most frequent outcomes. Weightlessness and control groups were compared. Results: 62 articles were included with a total of 963 participants involved. The meta-analysis showed that heart rate increased in SF [Mean difference (MD) = 3.44; p = 0.01] and in CS (MD = 4.98; p < 0.0001), whereas cardiac output and stroke volume decreased in CS (MD = -0.49; p = 0.03; and MD = -12.95; p < 0.0001, respectively), and systolic arterial pressure decreased in AS (MD = -5.20; p = 0.03). According to the qualitative synthesis, jugular vein cross-sectional area (CSA) and volume were greater in all conditions, and SF had increased carotid artery CSA. Heart rate variability and baroreflex sensitivity, in general, decreased in SF and CS, whereas both increased in AS. Conclusion: This review indicates that weightlessness impairs the health of astronauts during and after spaceflight, similarly to the effects of aging and immobility, potentially increasing the risk of cardiovascular diseases. Systematic Review Registration: https://www.crd.york.ac.uk/prospero/, identifier CRD42020215515.

2.
Respir Care ; 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39013568

RESUMO

BACKGROUND: PEEP is a cornerstone treatment for children with pediatric ARDS. Unfortunately, its titration is often performed solely by evaluating oxygen saturation, which can lead to inadequate PEEP level settings and consequent adverse effects. This study aimed to assess the impact of increasing PEEP on hemodynamics, respiratory system mechanics, and oxygenation in children with ARDS. METHODS: Children receiving mechanical ventilation and on pressure-controlled volume-guaranteed mode were prospectively assessed for inclusion. PEEP was sequentially changed to 5, 12, 10, 8 cm H2O, and again to 5 cm H2O. After 10 min at each PEEP level, hemodynamic, ventilatory, and oxygenation variables were collected. RESULTS: A total of 31 subjects were included, with median age and weight of 6 months and 6.3 kg, respectively. The main reasons for pediatric ICU admission were respiratory failure caused by acute viral bronchiolitis (45%) and community-acquired pneumonia (32%). Most subjects had mild or moderate ARDS (45% and 42%, respectively), with a median (interquartile range) oxygenation index of 8.4 (5.8-12.7). Oxygen saturation improved significantly when PEEP was increased. However, although no significant changes in blood pressure were observed, the median cardiac index at PEEP of 12 cm H2O was significantly lower than that observed at any other PEEP level (P = .001). Fourteen participants (45%) experienced a reduction in cardiac index of > 10% when PEEP was increased to 12 cm H2O. Also, the estimated oxygen delivery was significantly lower, at 12 cm H2O PEEP. Finally, respiratory system compliance significantly reduced when PEEP was increased. At a PEEP of 12 cm H2O, static compliance had a median reduction of 25% in relation to the initial assessment (PEEP of 5 cm H2O). CONCLUSIONS: Although it may improve arterial oxygen saturation, inappropriately high PEEP levels may reduce cardiac output, oxygen delivery, and respiratory system compliance in pediatric subjects with ARDS with low potential for lung recruitability.

3.
Braz J Cardiovasc Surg ; 39(4): e20230155, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39038084

RESUMO

OBJECTIVE: This study aimed to compare hemodynamic performances and clinical outcomes of patients with small aortic annulus (SAA) who underwent aortic valve replacement by means of sutureless aortic valve replacement (SUAVR) or transcatheter aortic valve implantation (TAVI). METHODS: From 2015 to 2020, 622 consecutive patients with SAA underwent either SUAVR or TAVI. Through a 1:1 propensity score matching analysis, two homogeneous groups of 146 patients were formed. Primary endpoint: all cause-death at 36 months. Secondary endpoints: incidence of moderate to severe patient-prosthesis mismatch (PPM) and incidence of major adverse cardiovascular and cerebrovascular events (MACCEs). RESULTS: All-cause death at three years was higher in the TAVI group (SUAVR 12.2% vs. TAVI 21.0%, P=0.058). Perioperatively, comparable hemodynamic performances were recorded in terms of indexed effective orifice area (SUAVR 1.12 ± 0.23 cm2/m2 vs. TAVI 1.17 ± 0.28 cm2/m2, P=0.265), mean transvalvular gradients (SUAVR 12.9 ± 5.3 mmHg vs. TAVI 12.2 ± 6.2 mmHg, P=0.332), and moderate-to-severe PPM (SUAVR 4.1% vs. TAVI 8.9%, P=0.096). TAVI group showed a higher cumulative incidence of MACCEs at 36 months (SUAVR 18.1% vs. TAVI 32.6%, P<0.001). Pacemaker implantation (PMI) and perivalvular leak ≥ 2 were significantly higher in TAVI group and identified as independent predictors of mortality (PMI: hazard ratio [HR] 3.05, 95% confidence interval [CI] 1.34-6.94, P=0.008; PPM: HR 2.72, 95% CI 1.25-5.94, P=0.012). CONCLUSION: In patients with SAA, SUAVR and TAVI showed comparable hemodynamic performances. Moreover, all-cause death and incidence of MACCEs at follow-up were significantly higher in TAVI group.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Hemodinâmica , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Hemodinâmica/fisiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Resultado do Tratamento , Procedimentos Cirúrgicos sem Sutura/métodos , Próteses Valvulares Cardíacas , Estudos Retrospectivos , Complicações Pós-Operatórias , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
4.
Rev. Enferm. Cent.-Oeste Min. ; 14: 4998, jun. 2024.
Artigo em Português | LILACS, BDENF - Enfermagem | ID: biblio-1566367

RESUMO

ResumoObjetivo: Avaliar a dificuldade na visibilidade e palpação da rede venosa periférica em adultos e idosos admitidos em uma unidade de intervenção hemodinâmica. Método:Trata-se de um estudo observacional e prospectivo com abordagem quantitativa. Realizado com 105 participantes, dentre adultos e idosos, admitidos em unidade de intervenção hemodinâmica, em um hospital geral público e de ensino. Os dados foram coletados por meio de instrumento estruturado contendo variáveis demográficas e clínicas, com observação da punção intravenosa periférica. Realizou-se a análise descritiva, calculando as proporções. Resultados: A dificuldade durante a palpação e a visualização da veia foram de 11,4% e 16,2%, respectivamente. Entre os participantes que apresentaram dificuldade para visualização da veia, 60% tiveram insucesso na primeira tentativa de punção. Conclusão: A punção periférica em veias que possuem maior dificuldade para visibilidade e palpação contribuem para o insucesso na primeira tentativa.


AbstractObjective: To evaluate the difficulty in visibility and palpation of the peripheral venous network in adults and older adults admitted to a hemodynamic intervention unit. Method: An observational prospective study was conducted with 105 adults and older adults admitted to a hemodynamic intervention unit, in a public general teaching hospital. Data were collected by means of a structured instrument consisting of demographic and clinical variables, with observation of peripheral intravenous puncture from October to December 2022. Descriptive analysis was performed, calculating proportions. Results: Results show a difficulty during palpation and visualization of the vein of 11.4% and 16.2%, respectively. Among those who had difficulty visualizing the vein, 60% were unsuccessful in the first puncture attempt. Conclusion: Peripheral puncture in veins with greater visibility and palpation difficulty contribute to failure in the first attempt


ResumenObjetivo: Evaluar la dificultad de visibilidad y de palpación de la red venosa periférica en adultos y ancianos ingresados en una unidad de intervención hemodinámica. Método: Se trata de un estudio observacional y prospectivo con enfoque cuantitativo. Participaron 105 adultos y ancianos ingresados en una unidad de intervención hemodinámica, en un hospital general público y universitario. Los datos se recolectaron mediante un instrumento estructurado, que contiene variables demográficas y clínicas, con observación de punción intravenosa periférica, durante los meses de octubre a diciembre de 2022. Se realizó un análisis descriptivo en el cual se calculó las proporciones. Resultados: La dificultad reportada durante la palpación y la visualización de la vena fue del 11,4% y el 16,2%, respectivamente. Entre los participantes que tuvieron dificultades en la visualización de la vena, el 60% falló en el primer intento de punción. Conclusión:La punción de venas periféricas que presentan mayores dificultades en la visibilidad y la palpación tiene tendencia a fallar en el primer intento


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Palpação , Cateterismo Periférico , Enfermagem , Adulto , Hemodinâmica
5.
Sci Rep ; 14(1): 13178, 2024 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-38849403

RESUMO

Cardiovascular diseases can be an emerging complication in cystic fibrosis (CF), as the median life expectancy has improved considerably. The objective of this study was to compare vascular, hemodynamic parameters and arterial stiffness in adult CF patients with healthy participants pared by sex and age, and to assess the factors associated with arterial stiffness in the CF group. This is a cross-sectional observational study. The evaluation of cardiovascular parameters was performed non-invasively using Mobil-O-Graph. 36 individuals with CF and 35 controls were evaluated. The mean arterial pressure (96.71 ± 10.98 versus 88.61 ± 7.40 mmHg, p = 0.0005), cardiac output (4.86 ± 0.57 versus 4.48 ± 0.44 L/min, p = 0.002) and systolic volume (64.30 ± 11.91 versus 49.02 ± 9.31 ml, p < 0.0001) were significantly lower in the CF group. The heart rate was higher in the CF when compared to the control (77.18 ± 10.47 versus 93.56 ± 14.57 bpm, p < 0.0001). The augmentation index (AIx@75) was higher in the CF than control (29.94 ± 9.37 versus 16.52 ± 7.179%, p < 0.0001). In the multivariate model controlled by body mass index and Forced Expiratory Volume in the first second, central systolic blood pressure and reflection coefficient directly related to AIx@75. Negatively related to AIx@75 were age and systolic volume. The adjusted determination coefficient was 87.40%. Individuals with CF presented lower arterial blood pressures and changes in cardiac function with lower stroke volume and cardiac output. The AIx@75, an indirect index of arterial stiffness and direct index of left ventricular overload, is increased in this population. The subclinical findings suggest the need for earlier cardiovascular assessment in this population due to increased risks of cardiovascular disease.


Assuntos
Fibrose Cística , Hemodinâmica , Rigidez Vascular , Humanos , Fibrose Cística/fisiopatologia , Masculino , Feminino , Adulto , Estudos Transversais , Adulto Jovem , Pressão Sanguínea , Doenças Cardiovasculares/fisiopatologia , Doenças Cardiovasculares/etiologia , Frequência Cardíaca , Débito Cardíaco/fisiologia
6.
Comput Biol Med ; 178: 108706, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38879935

RESUMO

BACKGROUND: Physics-informed neural networks (PINNs) have emerged as a powerful tool for solving inverse problems, especially in cases where no complete information about the system is known and scatter measurements are available. This is especially useful in hemodynamics since the boundary information is often difficult to model, and high-quality blood flow measurements are generally hard to obtain. METHODS: In this work, we use the PINNs methodology for estimating reduced-order model parameters and the full velocity field from scatter 2D noisy measurements in the aorta. Two different flow regimes, stationary and transient were studied. RESULTS: We show robust and relatively accurate parameter estimations when using the method with simulated data, while the velocity reconstruction accuracy shows dependence on the measurement quality and the flow pattern complexity. Comparison with a Kalman filter approach shows similar results when the number of parameters to be estimated is low to medium. For a higher number of parameters, only PINNs were capable of achieving good results. CONCLUSION: The method opens a door to deep-learning-driven methods in the simulations of complex coupled physical systems.


Assuntos
Modelos Cardiovasculares , Redes Neurais de Computação , Humanos , Velocidade do Fluxo Sanguíneo/fisiologia , Hemodinâmica/fisiologia , Aorta/fisiologia , Simulação por Computador
7.
Physiol Rep ; 12(13): e16131, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38942728

RESUMO

The hemodynamic response during the transition from the supine to standing position in idiopathic atrial fibrillation (AF) patients is not completely understood. This study aimed to analyze the hemodynamic changes that occur during the head-up tilt test in idiopathic AF patients. We investigated the hemodynamic changes during the head-up tilt test with impedance cardiography in 40 AF patients (12 with AF rhythm-AFr and 28 with sinus rhythm-AFsr) and 38 non-AF controls. Patients with AFr had attenuated SVI decrease after standing when compared to AFsr and non-AF [ΔSVI in mL/m2: -1.3 (-3.4 to 1.7) vs. -6.4 (-17.3 to -0.1) vs. -11.8 (-18.7 to -8.0), respectively; p < 0.001]. PVRI decreased in AFr but increased in AFsr and non-AF [ΔPVRI in dyne.seg.m2/cm5: -477 (-1148 to 82.5) vs. 131 (-525 to 887) vs. 357 (-29 to 681), respectively; p < 0.01]. Similarly, compared with non-AF patients, AFr patients also had a greater HR and greater CI increase after standing. The haemodynamic response to orthostatic challenge suggests differential adaptations between patients with AF rhythm and those reverted to sinus rhythm or healthy controls. Characterizing the hemodynamic phenotype may be relevant for the individualized treatment of AF patients.


Assuntos
Adaptação Fisiológica , Fibrilação Atrial , Hemodinâmica , Teste da Mesa Inclinada , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Teste da Mesa Inclinada/métodos , Pessoa de Meia-Idade , Idoso , Cardiografia de Impedância/métodos , Frequência Cardíaca
8.
Neurocrit Care ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38886326

RESUMO

BACKGROUND: Head elevation is recommended as a tier zero measure to decrease high intracranial pressure (ICP) in neurocritical patients. However, its quantitative effects on cerebral perfusion pressure (CPP), jugular bulb oxygen saturation (SjvO2), brain tissue partial pressure of oxygen (PbtO2), and arteriovenous difference of oxygen (AVDO2) are uncertain. Our objective was to evaluate the effects of head elevation on ICP, CPP, SjvO2, PbtO2, and AVDO2 among patients with acute brain injury. METHODS: We conducted a systematic review and meta-analysis on PubMed, Scopus, and Cochrane Library of studies comparing the effects of different degrees of head elevation on ICP, CPP, SjvO2, PbtO2, and AVDO2. RESULTS: A total of 25 articles were included in the systematic review. Of these, 16 provided quantitative data regarding outcomes of interest and underwent meta-analyses. The mean ICP of patients with acute brain injury was lower in group with 30° of head elevation than in the supine position group (mean difference [MD] - 5.58 mm Hg; 95% confidence interval [CI] - 6.74 to - 4.41 mm Hg; p < 0.00001). The only comparison in which a greater degree of head elevation did not significantly reduce the ICP was 45° vs. 30°. The mean CPP remained similar between 30° of head elevation and supine position (MD - 2.48 mm Hg; 95% CI - 5.69 to 0.73 mm Hg; p = 0.13). Similar findings were observed in all other comparisons. The mean SjvO2 was similar between the 30° of head elevation and supine position groups (MD 0.32%; 95% CI - 1.67% to 2.32%; p = 0.75), as was the mean PbtO2 (MD - 1.50 mm Hg; 95% CI - 4.62 to 1.62 mm Hg; p = 0.36), and the mean AVDO2 (MD 0.06 µmol/L; 95% CI - 0.20 to 0.32 µmol/L; p = 0.65).The mean ICP of patients with traumatic brain injury was also lower with 30° of head elevation when compared to the supine position. There was no difference in the mean values of mean arterial pressure, CPP, SjvO2, and PbtO2 between these groups. CONCLUSIONS: Increasing degrees of head elevation were associated, in general, with a lower ICP, whereas CPP and brain oxygenation parameters remained unchanged. The severe traumatic brain injury subanalysis found similar results.

9.
J Clin Monit Comput ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844603

RESUMO

Neurocritical patients frequently exhibit abnormalities in cerebral hemodynamics (CH) and/or intracranial compliance (ICC), all of which significantly impact their clinical outcomes. Transcranial Doppler (TCD) and the cranial micro-deformation sensor (B4C) are valuable techniques for assessing CH and ICC, respectively. However, there is a scarcity of data regarding the predictive value of these techniques in determining patient outcomes. We prospectively included neurocritical patients undergoing intracranial pressure (ICP) monitoring within the first 5 days of hospital admission for TCD and B4C assessments. Comprehensive clinical data were collected alongside parameters obtained from TCD (including the estimated ICP [eICP] and estimated cerebral perfusion pressure [eCPP]) and B4C (measured as the P2/P1 ratio). These parameters were evaluated individually as well as in combination. The short-term outcomes (STO) of interest were the therapy intensity levels (TIL) for ICP management recommended by the Seattle International Brain Injury Consensus Conference, as TIL 0 (STO 1), TIL 1-3 (STO 2) and death (STO 3), at the seventh day after last data collection. The dataset was randomly separated in test and training samples, area under the curve (AUC) was used to represent the noninvasive techniques ability on the STO prediction and association with ICP. A total of 98 patients were included, with 67% having experienced severe traumatic brain injury and 15% subarachnoid hemorrhage, whilst the remaining patients had ischemic or hemorrhagic stroke. ICP, P2/P1, and eCPP demonstrated the highest ability to predict early mortality (p = 0.02, p = 0.02, and p = 0.006, respectively). P2/P1 was the only parameter significant for the prediction of STO 1 (p = 0.03). Combining B4C and TCD parameters, the highest AUC was 0.85 to predict death (STO 3), using P2/P1 + eCPP, whereas AUC was 0.72 to identify ICP > 20 mmHg using P2/P1 + eICP. The combined noninvasive neuromonitoring approach using eCPP and P2/P1 ratio demonstrated improved performance in predicting outcomes during the early phase after acute brain injury. The correlation with intracranial hypertension was moderate, by means of eICP and P2/P1 ratio. These results support the need for interpretation of this information in the ICU and warrant further investigations for the definition of therapy strategies using ancillary tests.

10.
Physiol Meas ; 45(5)2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38749458

RESUMO

Objective.Diagnosis of incipient acute hypovolemia is challenging as vital signs are typically normal and patients remain asymptomatic at early stages. The early identification of this entity would affect patients' outcome if physicians were able to treat it precociously. Thus, the development of a noninvasive, continuous bedside monitoring tool to detect occult hypovolemia before patients become hemodynamically unstable is clinically relevant. We hypothesize that pulse oximeter's alternant (AC) and continuous (DC) components of the infrared light are sensitive to acute and small changes in patient's volemia. We aimed to test this hypothesis in a cohort of healthy blood donors as a model of slight hypovolemia.Approach.We planned to prospectively study blood donor volunteers removing 450 ml of blood in supine position. Noninvasive arterial blood pressure, heart rate, and finger pulse oximetry were recorded. Data was analyzed before donation, after donation and during blood auto-transfusion generated by the passive leg-rising (PLR) maneuver.Main results.Sixty-six volunteers (44% women) accomplished the protocol successfully. No clinical symptoms of hypovolemia, arterial hypotension (systolic pressure < 90 mmHg), brady-tachycardia (heart rate <60 and >100 beats-per-minute) or hypoxemia (SpO2< 90%) were observed during donation. The AC signal before donation (median 0.21 and interquartile range 0.17 a.u.) increased after donation [0.26(0.19) a.u;p< 0.001]. The DC signal before donation [94.05(3.63) a.u] increased after blood extraction [94.65(3.49) a.u;p< 0.001]. When the legs' blood was auto-transfused during the PLR, the AC [0.21(0.13) a.u.;p= 0.54] and the DC [94.25(3.94) a.u.;p= 0.19] returned to pre-donation levels.Significance.The AC and DC components of finger pulse oximetry changed during blood donation in asymptomatic volunteers. The continuous monitoring of these signals could be helpful in detecting occult acute hypovolemia. New pulse oximeters should be developed combining the AC/DC signals with a functional hemodynamic monitoring of fluid responsiveness to define which patient needs fluid administration.


Assuntos
Doadores de Sangue , Dedos , Fotopletismografia , Humanos , Projetos Piloto , Feminino , Masculino , Adulto , Dedos/irrigação sanguínea , Hemorragia/diagnóstico , Pessoa de Meia-Idade , Hipovolemia/diagnóstico , Hipovolemia/fisiopatologia , Oximetria , Doença Aguda , Adulto Jovem , Frequência Cardíaca
11.
J Clin Monit Comput ; 38(4): 783-789, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38381360

RESUMO

Perfusion Computed Tomography (PCT) is an alternative tool to assess cerebral hemodynamics during trauma. As acute traumatic subdural hematomas (ASH) is a severe primary injury associated with poor outcomes, the aim of this study was to evaluate the cerebral hemodynamics in this context. Five adult patients with moderate and severe traumatic brain injury (TBI) and ASH were included. All individuals were indicated for surgical evacuation. Before and after surgery, PCT was performed and cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) were evaluated. These parameters were associated with the outcome at 6 months post-trauma with the extended Glasgow Outcome Scale (GOSE). Mean age of population was 46 years (SD: 8.1). Mean post-resuscitation Glasgow coma scale (GCS) was 10 (SD: 3.4). Mean preoperative midline brain shift was 10.1 mm (SD: 1.8). Preoperative CBF and MTT were 23.9 ml/100 g/min (SD: 6.1) and 7.3 s (1.3) respectively. After surgery, CBF increase to 30.7 ml/100 g/min (SD: 5.1), and MTT decrease to 5.8s (SD:1.0), however, both changes don't achieve statistically significance (p = 0.06). Additionally, CBV increase after surgery, from 2.34 (SD: 0.67) to 2.63 ml/100 g (SD: 1.10), (p = 0.31). Spearman correlation test of postoperative and preoperative CBF ratio with outcome at 6 months was 0.94 (p = 0.054). One patient died with the highest preoperative MTT (9.97 s) and CBV (4.51 ml/100 g). CBF seems to increase after surgery, especially when evaluated together with the MTT values. It is suggested that the improvement in postoperative brain hemodynamics correlates to favorable outcome.


Assuntos
Lesões Encefálicas Traumáticas , Circulação Cerebrovascular , Escala de Coma de Glasgow , Hematoma Subdural Agudo , Tomografia Computadorizada por Raios X , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Adulto , Hematoma Subdural Agudo/diagnóstico por imagem , Hematoma Subdural Agudo/cirurgia , Tomografia Computadorizada por Raios X/métodos , Lesões Encefálicas Traumáticas/diagnóstico por imagem , Lesões Encefálicas Traumáticas/cirurgia , Seguimentos , Hemodinâmica , Escala de Resultado de Glasgow , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Resultado do Tratamento , Volume Sanguíneo Cerebral , Imagem de Perfusão/métodos , Perfusão
13.
J Dairy Sci ; 107(6): 4017-4032, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38246540

RESUMO

Holstein cattle carrying a prolactin receptor gene mutation (SLICK) exhibit short and sleek hair coats (short-haired Holstein [SLK]) enhancing thermotolerance and productivity compared with wild type-haired Holstein (WT) under tropical conditions. The objectives were to unravel the physiological and molecular mechanisms that confer an advantage to this slick genotype in Puerto Rico and determine potential correlations between metabolites and physiological variables. At 160 ± 3 DIM we compared vaginal temperatures (VT) and voluntary solar radiation exposure (VSRE) during 48 h between 9 SLK and 9 WT Holsteins, whereas a subsample of 7 SLK and 7 WT were used to assess udder skin temperature, mammary gland hemodynamics and transcriptomics, and blood plasma untargeted metabolomics at a single time point. The SLK cattle showed lower VT throughout the day and greater VSRE at 1000 h and 1100 h compared with their WT counterparts. Total mammary blood flow (MBF) was greater in SLK Holsteins compared with WT. The metabolite 9-nitrooctadecenoic acid was identified as a potential biomarker for MBF; moreover, SLK cattle had greater amounts of this metabolite in their plasma. Prostaglandin D2 synthase (PTGS) was upregulated in the slick mammary gland, while plasma prostaglandin D2 was positively correlated with milk yield and increased in SLK Holsteins compared with WT. Interestingly, the arachidonic acid metabolism pathway was enriched in the mammary gland transcriptome and perturbed in the blood metabolome in the SLK Holsteins. In conclusion, SLK Holsteins exhibited lower body temperatures, greater VSRE, enhanced blood supply to the mammary gland, and alterations in genes and metabolites involved in arachidonic acid metabolism at the mammary gland and blood plasma. The usage of the SLK Holstein cattle genetics in dairy operations could be a feasible alternative to mitigate the adverse consequences of heat stress.


Assuntos
Lactação , Glândulas Mamárias Animais , Animais , Bovinos , Feminino , Glândulas Mamárias Animais/metabolismo , Porto Rico , Hemodinâmica , Transcriptoma , Metabolômica
14.
Arq. bras. cardiol ; Arq. bras. cardiol;121(5): e20230678, 2024. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1557054

RESUMO

Resumo Fundamento Estudos prévios têm sido inconsistentes em demonstrar efeitos cardiovasculares benéficos da suplementação de vitamina D. Objetivo Avaliar efeitos da suplementação de vitamina D3 sobre parâmetros hemodinâmicos centrais e atividade autonômica em indivíduos obesos/sobrepeso e baixos níveis de vitamina D (<30ng/dl). Métodos Ensaio clínico prospectivo, randomizado, duplo-cego (NCT 05689632), adultos 40-65 anos com índice de massa corporal ≥25<40 kg/m2. Hemodinâmica central avaliada por método oscilométrico (Mobil-O-Graph®), variabilidade da frequência cardíaca utilizando frequencímetro Polar (software Kubios®). Os pacientes (n=53) receberam placebo no grupo controle (CO, n=25) ou vitamina D3 (VD, n=28) 7000 UI/dia, avaliados antes (S0) e após 8 semanas (S8) com nível de significância de 0,05. Resultados Os grupos foram homogêneos na idade (51±6 vs. 52±6 anos, p=0,509) e níveis de vitamina D (22,8±4,9 vs. 21,7±4,5ng/ml, p=0,590). Na S8, o grupo VD apresentou níveis significativamente maiores de vitamina D (22,5 vs. 35,6ng/ml, p<0,001). Apenas o grupo VD mostrou redução significativa da pressão arterial sistólica (PAS; 123±15 vs. 119±14mmHg, p=0,019) e fosfatase alcalina (213±55 vs. 202±55mg/dl, p=0,012). O grupo CO mostrou elevação da pressão de aumento (AP: 9 vs. 12mmHg, p=0,028) e do índice de incremento (Aix: 26 vs. 35%, p=0,020), o que não foi observado no grupo VD (AP: 8 vs. 8mmHg, Aix: 26 vs. 25%, p>0,05). Grupo VD apresentou aumento no índice do sistema nervoso (iSN) parassimpático (-0,64±0,94 vs. -0,16±1,10, p=0,028) e no intervalo R-R (866±138 vs. 924±161ms, p=0,026). Conclusão Nesta amostra, a suplementação diária de vitamina D durante oito semanas resultou em melhora dos níveis pressóricos, parâmetros hemodinâmicos centrais e do equilíbrio autonômico.


Abstract Background Previous studies have been inconsistent in demonstrating beneficial cardiovascular effects of vitamin D supplementation. Objective To evaluate the effects of vitamin D3 supplementation on central hemodynamic parameters and autonomic activity in obese/overweight individuals with low vitamin D levels (<30ng/dl). Methods Adults 40-65 years old with body mass index ≥25<40 kg/m2 were enrolled in this prospective, randomized, double-blind clinical trial (NCT 05689632). Central hemodynamics was assessed using the oscillometric method (Mobil-O-Graph®), and heart rate variability using a Polar heart rate monitor (Kubios® software). Patients (n=53) received a placebo in the control group (CO, n=25) or vitamin D3 (VD, n=28) 7000 IU/day, and were evaluated before (W0) and after 8 weeks (W8) with a significance level of 0.05. Results The groups were homogeneous regarding age (51±6 vs 52±6 years, p=0.509) and vitamin D levels (22.8±4.9 vs 21.7±4.5ng/ml, p=0.590). At W8, the VD group had significantly higher levels of vitamin D (22.5 vs 35.6ng/ml, p<0.001). Only the VD group showed a significant reduction in systolic blood pressure (SBP; 123±15 vs 119±14mmHg, p=0.019) and alkaline phosphatase (213±55 vs 202±55mg/dl, p=0.012). The CO group showed an increase in augmentation pressure (AP: 9 vs 12 mmHg, p=0.028) and augmentation index (AIx: 26 vs 35%, p=0.020), which was not observed in the VD group (AP: 8 vs 8 mmHg, AIx: 26 vs 25%, p>0.05). VD group showed an increase in the parasympathetic nervous system index (PNSi) (-0.64±0.94 vs -0.16±1.10, p=0.028) and the R-R interval (866±138 vs 924±161 ms, p= 0.026). Conclusion In this sample, eight weeks of daily vitamin D supplementation resulted in an improvement in blood pressure levels and autonomic balance.

15.
Braz. j. anesth ; 74(1): 744230, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1557224

RESUMO

Abstract Background and objective: Anesthesia induction can produce severe propofol dose-dependent hypotension. Fentanyl coadministration reduces the catecholaminergic response to orotracheal intubation allowing propofol dose reduction. The aim of this study is to determine whether the hemodynamic response is improved by increasing the time between fentanyl and propofol administration and reducing the dose of the latter without increasing the time to achieve optimal hypnosis. Methods: After approval by the Research Ethics Committee, patients undergoing non-cardiac surgery with endotracheal intubation were randomized by a computer-generated table into six time-dose groups (1 or 2 minutes/1, 1.5, or 2mg.kg-1 of propofol). Patients with high bronchoaspiration risk, a difficult airway, hemodynamic instability, or anesthetic allergies were excluded. After giving intravenous fentanyl (2 μg.kg-1 ), each group received different doses of propofol after 1 or 2 minutes. Non-invasive blood pressure (BP) and heart rate (HR) were measured at pre-induction, pre-intubation, and post-intubation. Time to hypnosis (bispectral index < 60) was also recorded. Results: Of the 192 recruited patients, 186 completed the study (1 min group n = 94; 2 min group n = 92). It was observed that HR and BP decreased after propofol administration and increased after intubation in all groups (p<0.0001). In patients over 55 years, the 2 min - 2 mg.kg-1 group showed the greatest systolic BP reduction (36 ± 12%) at pre-intubation, while the 1 min - 1.5 mg.kg-1 group showed the least hemodynamic alteration between pre- and post-intubation (-4 ± 13%). No significant differences were found in younger patients or in the time to reach hypnosis between the six groups. While no cases of severe bradycardia were recorded, 5,4% of the sample required vasopressors. Conclusion: Increasing the time between the administration of fentanyl and propofol by up to two minutes results in greater hypotension in patients over 55 years.

16.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;39(4): e20230155, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1569616

RESUMO

ABSTRACT Objective: This study aimed to compare hemodynamic performances and clinical outcomes of patients with small aortic annulus (SAA) who underwent aortic valve replacement by means of sutureless aortic valve replacement (SUAVR) or transcatheter aortic valve implantation (TAVI). Methods: From 2015 to 2020, 622 consecutive patients with SAA underwent either SUAVR or TAVI. Through a 1:1 propensity score matching analysis, two homogeneous groups of 146 patients were formed. Primary endpoint: all cause-death at 36 months. Secondary endpoints: incidence of moderate to severe patient-prosthesis mismatch (PPM) and incidence of major adverse cardiovascular and cerebrovascular events (MACCEs) Results: All-cause death at three years was higher in the TAVI group (SUAVR 12.2% vs. TAVI 21.0%, P=0.058). Perioperatively, comparable hemodynamic performances were recorded in terms of indexed effective orifice area (SUAVR 1.12 ± 0.23 cm2/m2 vs. TAVI 1.17 ± 0.28 cm2/m2, P=0.265), mean transvalvular gradients (SUAVR 12.9 ± 5.3 mmHg vs. TAVI 12.2 ± 6.2 mmHg, P=0.332), and moderate-to-severe PPM (SUAVR 4.1% vs. TAVI 8.9%, P=0.096). TAVI group showed a higher cumulative incidence of MACCEs at 36 months (SUAVR 18.1% vs. TAVI 32.6%, P<0.001). Pacemaker implantation (PMI) and perivalvular leak ≥ 2 were significantly higher in TAVI group and identified as independent predictors of mortality (PMI: hazard ratio [HR] 3.05, 95% confidence interval [CI] 1.34-6.94, P=0.008; PPM: HR 2.72, 95% CI 1.25-5.94, P=0.012). Conclusion: In patients with SAA, SUAVR and TAVI showed comparable hemodynamic performances. Moreover, all-cause death and incidence of MACCEs at follow-up were significantly higher in TAVI group.

17.
Clinics (Sao Paulo) ; 78: 100308, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38041986

RESUMO

OBJECTIVES: Traumatic hemorrhagic shock is a major death-related factor contributing to mortality in emergencies and can be effectively handled by the Limited Fluid Resuscitation (LFR) method. In the current investigation, the authors analyzed the influence of different administrating blood pressure on the treatment outcomes of LFR. METHODS: 276 participants were enrolled in the current study retrospectively from January 2016 to December 2021 and were divided into three groups based on the administrating blood pressure of LFR. The difference among the three groups regarding serum levels of cytokines as well as blood hemodynamics parameters was analyzed. RESULTS: The results showed after the T2 stage treatment, cytokine levels in the three groups were all significantly influenced by different LFR strategies with medium MAP showing the strongest effects on the expression of all cytokine genes. Moreover, the MAP value was in positive correlation with IL-6, IL-10, and TNF-α levels, but showed no clear relation with IL-4 level in all three groups. Regarding the effects on hemodynamics parameters, the levels of CVP, CO, and CI were slightly increased by the different LFR administrating strategies, and the effect of medium and high MAP was statistically stronger than that of low MAP. CONCLUSION: The present results showed that LFR would influence serum inflammatory levels by improving blood hemodynamics parameters. Medium MAP showed the strongest improving effects with the least side effects, which can be employed as the optimal administrating strategy for LFR in the future.


Assuntos
Choque Hemorrágico , Humanos , Choque Hemorrágico/terapia , Estudos Retrospectivos , Hemodinâmica , Citocinas , Resultado do Tratamento , Hidratação/métodos , Ressuscitação/métodos
18.
Arq. bras. cardiol ; Arq. bras. cardiol;120(12): e20230087, dez. 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1527797

RESUMO

Resumo Fundamento O Teste de Caminhada de seis Minutos (TC6M) é comumente usado para avaliar pacientes com insuficiência cardíaca. No entanto, vários fatores clínicos podem influenciar a distância percorrida pelos pacientes no teste. A cardiografia de impedância (CI) na avaliação morfológica é uma ferramenta útil para avaliar a hemodinâmica cardíaca de maneira não invasiva. Objetivo Este estudo teve como objetivo comparar as respostas de aceleração e desaceleração do Débito Cardíaco (DC), da Frequência Cardíaca (FC), e do Volume Sistólico (VS) ao TC6M de indivíduos com insuficiência cardíaca e fração de ejeção reduzida (ICFEr) com as de controles sadios. Métodos Este é um estudo transversal observacional. O DC, a FC, o VS e o Índice Cardíaco (IC) foram avaliados antes, durante e após o TC6M por CI. O nível de significância adotado na análise estatística foi 5%. Resultados Foram incluídos 27 participantes (13 com ICFEr e 14 controles sadios). A aceleração do DC e da FC foi significativamente diferente entre os grupos (p<0,01 e p=0,039, respectivamente). Encontramos diferenças significativas no VS, no DC e no IC entre os grupos (p<0,01). A regressão linear mostrou uma contribuição deficiente do VS à mudança no DC no grupo com ICFEr (22,9% versus 57,4%). Conclusão O principal resultado deste estudo foi o fato de que indivíduos com ICFEr apresentaram valores mais baixos de aceleração do DC e da FC durante o teste de exercício submáximo em comparação a controles sadios. Isso pode indicar um desequilíbrio na resposta autonômica ao exercício nessa condição.


Abstract Background The six-minute walk test (6MWT) is commonly used to evaluate heart failure (HF) patients. However, several clinical factors can influence the distance walked in the test. Signal-morphology impedance cardiography (SM-ICG) is a useful tool to noninvasively assess hemodynamics. Objective This study aimed to compare cardiac output (CO), heart rate (HR), and stroke volume (SV) acceleration and deceleration responses to 6MWT in individuals with HF and reduced ejection fraction (HFrEF) and healthy controls. Methods This is a cross-sectional observational study. CO, HR, SV and cardiac index (CI) were evaluated before, during, and after the 6MWT assessed by SM-ICG. The level of significance adopted in the statistical analysis was 5%. Results Twenty-seven participants were included (13 HFrEF and 14 healthy controls). CO and HR acceleration significantly differed between groups (p<0.01; p=0.039, respectively). We found significant differences in SV, CO and CI between groups (p<0.01). Linear regression showed an impaired SV contribution to CO change in HFrEF group (22.9% versus 57.4%). Conclusion The main finding of the study was that individuals with HFrEF showed lower CO and HR acceleration values during the submaximal exercise test compared to healthy controls. This may indicate an imbalance in the autonomic response to exercise in this condition.

19.
Rev. argent. cardiol ; 91(5): 345-351, dic. 2023. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1550698

RESUMO

RESUMEN Introducción: la preeclampsia (PE) es la principal causa de morbimortalidad materno-fetal en nuestro país. Alteraciones hemodinámicas precoces durante el embarazo podrían predecir la evolución a PE. El machine learning (ML) permite el hallazgo de patrones ocultos que podrían detectar precozmente el desarrollo de PE. Objetivos: desarrollar un árbol de clasificación con variables de hemodinamia no invasiva para predecir precozmente desarrollo de PE. Material y métodos: estudio observacional prospectivo con embarazadas de alto riesgo (n=1155) derivadas del servicio de Obstetricia desde enero 2016 a octubre 2022 para el muestreo de entrenamiento por ML con árbol de clasificación j48. Se seleccionaron 112 embarazadas entre semanas 10 a 16, sin tratamiento farmacológico y que completaron el seguimiento con el término de su embarazo con evento final combinado (PE): preeclampsia, eclampsia y síndrome HELLP. Se evaluaron simultáneamente con cardiografía de impedancia y velocidad de onda del pulso y con monitoreo ambulatorio de presión arterial de 24 hs (MAPA). Resultados: presentaron PE 17 pacientes (15,18%). Se generó un árbol de clasificación predictivo con las siguientes variables: índice de complacencia arterial (ICA), índice cardíaco (IC), índice de trabajo sistólico (ITS), cociente de tiempos eyectivos (CTE), índice de Heather (IH). Se clasificaron correctamente el 93,75%; coeficiente Kappa 0,70, valor predictivo positivo (VPP) 0,94 y negativo (VPN) 0,35. Precisión 0,94, área bajo la curva ROC 0,93. Conclusión: las variables ICA, IC, ITS, CTE e IH predijeron en nuestra muestra el desarrollo de PE con excelente discriminación y precisión, de forma precoz, no invasiva, segura y con bajo costo.


ABSTRACT Background: Preeclampsia (PE) is the main cause of maternal-fetal morbidity and mortality in our country. Early hemodynamic changes during pregnancy could predict progression to PE. Machine learning (ML) enables the discovery of hidden patterns that could early detect PE development. Objectives: The aim of this study was to build a classification tree with non-invasive hemodynamic variables for the early prediction of PE occurrence. Results: Seventeen patients (15.18%) presented PE. A predictive classification tree was generated with arterial compliance index (ACI), cardiac index (CI), cardiac work index (CWI), ejective time ratio (ETR), and Heather index (HI). A total of 93.75% patients were correctly classified (Kappa 0.70, positive predictive value 0.94 and negative predictive value 0.35; accuracy 0.94, and area under the ROC curve 0.93). Conclusion: ACI, CI, CWI, ETR and HI variables predicted the early development of PE in our sample with excellent discrimination and accuracy, non-invasively, safely and at low cost.

20.
Int. j. morphol ; 41(6): 1751-1757, dic. 2023. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1528791

RESUMO

SUMMARY: To observe the effect of sevoflurane combined with brachial plexus block (BPB) in children with humeral fracture surgery and its effect on hemodynamics. 84 children who received surgical treatment of humeral fracture in our hospital from September 2019 to September 2022 were selected. According to different anesthesia methods, the children were divided into control group and study group. The control group only received laryngeal mask sevoflurane; the study group received laryngeal mask sevoflurane combined with BPB. The operation situation, hemodynamic indexes, stress level, pain and adverse reactions of children was observed. The postoperative awakening time in the study group was lower than control group, the postoperative pain onset time in the study group was higher than control group (P0.05). Postoperative 2h, the levels of serum cortisol, b-endorpin, norepinephrine and epinephrine in the study group were lower than control group (P0.05). Sevoflurane combined with BPB is helpful to shorten the postoperative awakening time of children with humeral fracture, reduce the degree of postoperative pain, improve hemodynamics, and reduce stress response, and has good safety.


El objetivo fue observar el efecto del sevoflurano combinado con bloqueo del plexo braquial (BPB) en niños con cirugía de fractura de húmero y su efecto sobre la hemodinámica. Se seleccionaron 84 niños que recibieron tratamiento quirúrgico de fractura de húmero en nuestro hospital desde septiembre de 2019 hasta septiembre de 2022. Según diferentes métodos de anestesia, los niños se dividieron en grupo control y grupo de estudio. El grupo control solo recibió sevoflurano en mascarilla laríngea; el grupo de estudio recibió sevoflurano con mascarilla laríngea combinado con BPB. Se observó la situación operatoria, índices hemodinámicos, nivel de estrés, dolor y reacciones adversas de los niños. El tiempo hasta el despertar postoperatorio en el grupo de estudio fue menor que el del grupo control, el tiempo de aparición del dolor postoperatorio en el grupo de estudio fue mayor que el del grupo control (P0,05). A las 2 horas postoperatorias, los niveles séricos de cortisol, β-endorfina, norepinefrina y epinefrina en el grupo de estudio fueron más bajos que los del grupo control (P 0,05). El sevoflurano combinado con BPB es útil para acortar el tiempo de despertar del posoperatorio de los niños con fractura de húmero, reduce el grado de dolor postoperatorio, mejora la hemodinámica y reduce la respuesta al estrés, además de tener buena seguridad.


Assuntos
Humanos , Masculino , Feminino , Criança , Bloqueio do Plexo Braquial , Sevoflurano/administração & dosagem , Fraturas do Úmero/cirurgia , Anestésicos Inalatórios , Hemodinâmica/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA