Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
1.
Odontology ; 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39240393

RESUMO

To evaluate the effect of build direction, post-polymerization time, and aging on the fracture resistance, failure mode, margin quality and Marginal (MD) and Internal Discrepancies (ID), and degree of conversion of tridimensional (3D) printed provisional crowns using the liquid crystal display technique (LCD). A left mandibular first molar was prepared and scanned. After, a full crown was designed (ExoCad) and exported to the LCD-printer software. One hundred and eighty crowns were printed at two build directions (30°, 90°) and post-polymerized for different periods (15, 30, 45 min). Half of the samples were aged (ST) in distilled water (37 °C/90 days). The marginal quality of the crowns was evaluated by the Schriwer method under a stereomicroscope (40x). The replica technique was used to measure the MD and ID and measured under a stereomicroscope (10x), through 20 reference points defined in 5 regions: Occlusal (O), Cusp (CP), Axial (AX), Chamfer (CH), and Finish Line (F). After, the crowns were cemented onto the respective dies using temporary cement and submitted to compression test (ISO150, 1 mm/min, 100 kgf).The failure mode was classified by Burke's fracture mode. The degree of conversion was evaluated through Fourier Transform Infrared Spectroscopy. The data (µm) of MD and ID and fracture resistance (N) were subjected to ANOVA (3 factors) and Tukey's test (5%); Weibull analysis was also performed for fracture resistance data (N). For MD, ID and fracture resistance ANOVA revealed that all factors (P < .001) were significant. For aged groups, the crowns printed at 30° showed lower MD (Tukey). The O_90_30 min (172.13A µm) and O_90_15 min (170.20A µm) groups showed the highest ID values. Higher resistance values were observed for the 30_45 min (844.30A N), 30_30 min (835.35A N), and 90_30 min (820.62A N) groups (Tukey). In the margin analysis, 98.6% of the crowns printed at 30° showed smooth margins without defects. The most prevalent fracture mode (41.7%) was Burke type 5. The degree of conversion (DC) increased with increasing post-polymerization time and aging. Printing provisional crowns at 30° provided lower crown MD and ID, as well as higher fracture resistance. A post-polymerization time of 30 min resulted in higher crown fracture resistance, while aging reduced the resistance of the crowns.

3.
Saudi Dent J ; 36(6): 887-893, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38883896

RESUMO

Purpose: This prospective study evaluated the effects of the metal-free crowns on the periodontal tissues of abutment teeth during a 12-month follow-up. Materials and Methods: A sample of 24 patients (N = 32 abutment teeth) who needed a single-tooth restoration were enrolled to receive either a metal-ceramic (n = 21) or lithium disilicate (n = 11). The single-unit crowns were evaluated at baseline, 3-and 12-month follow-up. The periodontal parameters were evaluated: plaque index (PI), gingival bleeding index (GBI), bleeding on probing (BOP), probing depth (PD), clinical attachment loss (CAL), radiographically and clinical crown fitting, bone resorption, and marginal finish lines. Statistical analyses were performed using the Exact Fisher and Mann-Whitney tests, and the Wilcoxon signed-rank test as a post hoc test for Friedman (95 % confidence interval). Results: The marginal finish line showed a statistical difference with a biomaterial type (p =.004). After a 12-months, a significant increase was observed in PI and mean PD for abutment teeth of metal-ceramic crowns. The metal-free crowns presented higher values for GBI and CAL (p2 < 0.05). Only distal cervical evaluation and dental biofilm formation in the abutment teeth showed a statistical difference between the groups at the 12-month follow-up. The supragingival margin metal-ceramic group revealed higher PI values (p2 = 0.005) between the period and the subgingival margin of both biomaterials showed greater GBI scores (p2 < 0.05). Conclusions: Metal-free crowns showed better periodontal outcomes compared to metal-ceramic crowns. Single-unit crown marginal location affects the periodontal tissue condition of the abutment teeth. The marginal fit was not changed regarding the biomaterial type.

4.
Entropy (Basel) ; 26(6)2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38920519

RESUMO

Ensuring that the proposed probabilistic model accurately represents the problem is a critical step in statistical modeling, as choosing a poorly fitting model can have significant repercussions on the decision-making process. The primary objective of statistical modeling often revolves around predicting new observations, highlighting the importance of assessing the model's accuracy. However, current methods for evaluating predictive ability typically involve model comparison, which may not guarantee a good model selection. This work presents an accuracy measure designed for evaluating a model's predictive capability. This measure, which is straightforward and easy to understand, includes a decision criterion for model rejection. The development of this proposal adopts a Bayesian perspective of inference, elucidating the underlying concepts and outlining the necessary procedures for application. To illustrate its utility, the proposed methodology was applied to real-world data, facilitating an assessment of its practicality in real-world scenarios.

5.
Cir Cir ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467075

RESUMO

Objective: Screening is an effective tool for detecting colorectal lesions in asymptomatic subjects. There is a positive correlation between fecal immunochemical test (FIT) values and the size of tumors. Despite the efficacy of screening, the detection of colorectal cancer (CRC) remains low. The primary objective was to evaluate the best FIT cutoff value for detecting advanced adenomas and CRC among individuals at average risk in a country with a high incidence and morbidity from CRC. Methods: This observational and prospective study analyzed consecutive cases in 1461 asymptomatic subjects with a positive FIT (≥ 100 ng hemoglobin [Hb]/mL) referred for colonoscopy (2012-2015) at a tertiary center in Uruguay. Results: Colorectal lesions were detected in 35.3% (516/1461) of cases, with a mean age of 62.8 ± 8.3 years. About 53.2% were men and 65.1% of the tumors were located in the left side of the colon. The size of the lesion and FIT values (p = 0.001) were positively correlated. Laterally spreading tumors predominated in the right colon (586 ng Hb/mL; 95% Confidence interval [CI] 443.4-760). One hundred and thirty-five (26%) lesions were advanced adenomas (15 ± 6.7 mm); 694.6 ng/mL; 95% CI 632.4-756.9). The highest diagnostic yield (0.5112) for advanced adenomas was at a FIT level of 400 ng Hb/mL (accuracy 88.6%). There were significant differences in FIT values early and advanced CRC (927 ng/mL; [95% CI: 637-1082] vs. 1453 [95% CI: 1352-1594; p = 0.001]). Conclusion: A FIT value of 400 ng Hb/mL was the best diagnostic yield to detect advanced adenomas and CRC. This value is useful during the COVID-19 pandemic as it allows prioritization of colonoscopy to those most at risk of significant disease, thus reducing risks to both patients and healthcare workers.


Objetivo: El cribado es una herramienta eficaz para detectar lesiones colorrectales en sujetos asintomáticos. Existe una correlación positiva entre los valores de la prueba inmunoquímica fecal (FIT) y el tamaño de los tumores. A pesar de la eficacia del cribado, la detección del cáncer colorrectal (CCR) sigue siendo baja. El objetivo principal fue evaluar el mejor valor de corte FIT para detectar adenomas avanzados y CCR entre personas con riesgo promedio en un país con alta incidencia y morbilidad por CCR. Métodos: Este estudio observacional y prospectivo analizó 1461 sujetos asintomáticos con FIT positivo (≥ 100 ng de hemoglobina [Hb]/mL) remitidos para colonoscopia (2012-2015) en un centro terciario en Uruguay. Resultados: Se detectaron lesiones colorrectales en el 35,3% (516/1461) de los casos, con una edad media de 62,8 ± 8,3 años. Alrededor del 53,2% eran hombres y el 65,1% de los tumores estaban ubicados en el lado izquierdo del colon. El tamaño de la lesión y los valores FIT (p = 0,001) se correlacionaron positivamente. Los tumores con extensión lateral predominaron en el colon derecho (586 ng Hb/mL; intervalo de confianza [IC] del 95%: 443,4-760). Ciento treinta y cinco (26%) lesiones fueron adenomas avanzados (15 ± 6,7 mm); 694,6 ng/ml; IC 95% 632,4-756,9). El rendimiento diagnóstico más alto (0,5112) para los adenomas avanzados se obtuvo con un nivel FIT de 400 ng Hb/ml (precisión del 88,6%). Hubo diferencias significativas en los valores de FIT de CCR temprano y avanzado (927 ng/mL; [IC 95%: 637-1082] vs. 1453 [IC 95%: 1352-1594; p = 0,001]). Conclusión: Un valor FIT de 400 ng Hb/mL fue el mejor rendimiento diagnóstico para detectar adenomas avanzados y CCR. Este valor es útil durante la pandemia de COVID-19, ya que permite priorizar la colonoscopia a aquellos con mayor riesgo de padecer una enfermedad importante, reduciendo así los riesgos tanto para los pacientes como para los trabajadores de la salud.

6.
Rev. Asoc. Odontol. Argent ; 111(3): 3-3, dic. 2023. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1550643

RESUMO

Resumen Objetivo Comparar dos procedimientos de soldadura convencionales empleando una aleación de Cr-Co, para conectar barras coladas seccionadas a ser fijadas sobre implantes. Materiales y métodos A partir de un modelo maestro que representa un maxilar desdentado con cuatro implantes, se confeccionaron veinte (n=20) probetas seccionadas en tres partes. Se conformaron dos grupos, cada uno con diez (n=10) ejemplares. Una vez acondicionadas, fueron atornilladas al modelo maestro. Su desajuste inicial se analizó utilizando una lupa estereoscópica, con una cámara incorporada y un software. Las partes fueron soldadas empleando un procedimiento diferente para cada grupo. Las correspondientes al Grupo I se invistieron en un block refractario a base de sílico-fosfato. Las del Grupo II se montaron en una estructura metálica Clever Spider. El desajuste fue mensurado y los resultados procesados estadísticamente. El nivel de significación fue establecido en p<0,05. Resultados El Grupo I tuvo un desajuste inicial de 97,30±13,81μm y el Grupo II de 98,53±11,24μm. Luego de la soldadura, el Grupo I registró 98,53±17,17μm, 1,23μm mayor respecto al inicial. En el Grupo II se observó 103,13±17,61μm, 4,60μm por encima del original. Se analizaron mediante prueba t de Student; en ambos casos el resultado fue de p>0,05. Al comparar entre sí los grupos I y II, por medio de la prueba t y de comprobación no paramétrica de Mann-Whitney, se observaron diferencias no significativas, p=0,41 y p=0,38 respectivamente. Conclusiones Bajo las condiciones de este estudio, se observó que los dos métodos de soldadura analizados fueron confiables para unir supraestructurasos metálicas sin que se afecte su ajuste final.


Abstract Aim Compare two conventional welding procedures using a Cr-Co alloy, to connect sectioned cast bars to be fixed on implants. Materials and methods From a master model representing a toothless jaw with four implants, twenty (n=20) specimens sectioned into three parts were made. Two groups were formed, each with ten (n=10) specimens. Once conditioned, they were screwed to the master model. Its initial mismatch was analyzed using a stereoscopic magnifier, with a built-in camera and a software. The parts were welded using a different procedure for each group. Those corresponding to Group I were invested in a refractory block based on silyl-phosphate. Those of Group II were mounted on a Clever Spider metal structure. The mismatch was measured, and the results processed statistically. The level of significance was established at p<0.05. Results Group I had an initial mismatch of 97.30 ±13.81μm, and Group II of 98.53±11.24μm. After welding, Group I registered 98.53±17.17μm, 1.23μm higher than the initial one. In Group II, 103.13±17.61μm was observed, 4.60μm above the original. They were analyzed using Student's t test; in both cases the result was p>0.05. When comparing groups I and II, using the t-test and the Mann-Whitney nonparametric verification, non-significant differences were observed, p=0.41 and p=0.38 respectively. Conclusions Under the conditions of this study, it was observed that the two welding methods analyzed were reliable for joining metallic superstructures without affecting their final fit.

7.
Rev. Asoc. Odontol. Argent ; 111(3): 2-2, dic. 2023. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1550642

RESUMO

Resumen Objetivo Comparar dos procedimientos de soldadura convencionales empleando una aleación de Cr-Co, para conectar barras coladas seccionadas a ser fijadas sobre implantes. Materiales y métodos A partir de un modelo maestro que representa un maxilar desdentado con cuatro implantes, se confeccionaron veinte (n=20) probetas seccionadas en tres partes. Se conformaron dos grupos, cada uno con diez (n=10) ejemplares. Una vez acondicionadas, fueron atornilladas al modelo maestro. Su desajuste inicial se analizó utilizando una lupa estereoscópica, con una cámara incorporada y un software. Las partes fueron soldadas empleando un procedimiento diferente para cada grupo. Las correspondientes al Grupo I se invistieron en un block refractario a base de sílico-fosfato. Las del Grupo II se montaron en una estructura metálica Clever Spider. El desajuste fue mensurado y los resultados procesados estadísticamente. El nivel de significación fue establecido en p<0,05. Resultados El Grupo I tuvo un desajuste inicial de 97,30±13,81μm y el Grupo II de 98,53±11,24μm. Luego de la soldadura, el Grupo I registró 98,53±17,17μm, 1,23μm mayor respecto al inicial. En el Grupo II se observó 103,13±17,61μm, 4,60μm por encima del original. Se analizaron mediante prueba t de Student; en ambos casos el resultado fue de p>0,05. Al comparar entre sí los grupos I y II, por medio de la prueba t y de comprobación no paramétrica de Mann-Whitney, se observaron diferencias no significativas, p=0,41 y p=0,38 respectivamente. Conclusiones Bajo las condiciones de este estudio, se observó que los dos métodos de soldadura analizados fueron confiables para unir supraestructurasos metálicas sin que se afecte su ajuste final.


Abstract Aim Compare two conventional welding procedures using a Cr-Co alloy, to connect sectioned cast bars to be fixed on implants. Materials and methods From a master model representing a toothless jaw with four implants, twenty (n=20) specimens sectioned into three parts were made. Two groups were formed, each with ten (n=10) specimens. Once conditioned, they were screwed to the master model. Its initial mismatch was analyzed using a stereoscopic magnifier, with a built-in camera and a software. The parts were welded using a different procedure for each group. Those corresponding to Group I were invested in a refractory block based on silyl-phosphate. Those of Group II were mounted on a Clever Spider metal structure. The mismatch was measured, and the results processed statistically. The level of significance was established at p<0.05. Results Group I had an initial mismatch of 97.30 ±13.81μm, and Group II of 98.53±11.24μm. After welding, Group I registered 98.53±17.17μm, 1.23μm higher than the initial one. In Group II, 103.13±17.61μm was observed, 4.60μm above the original. They were analyzed using Student's t test; in both cases the result was p>0.05. When comparing groups I and II, using the t-test and the Mann-Whitney nonparametric verification, non-significant differences were observed, p=0.41 and p=0.38 respectively. Conclusions Under the conditions of this study, it was observed that the two welding methods analyzed were reliable for joining metallic superstructures without affecting their final fit.

8.
Rev. Asoc. Odontol. Argent ; 111(3): 1111212, sept.-dic. 2023. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1554482

RESUMO

Objetivo: Comparar dos procedimientos de soldadura convencionales empleando una aleación de Cr-Co, para co- nectar barras coladas seccionadas a ser fijadas sobre implantes. Materiales y métodos: A partir de un modelo maes- tro que representa un maxilar desdentado con cuatro implan- tes, se confeccionaron veinte (n=20) probetas seccionadas en tres partes. Se conformaron dos grupos, cada uno con diez (n=10) ejemplares. Una vez acondicionadas, fueron atornilla- das al modelo maestro. Su desajuste inicial se analizó utili- zando una lupa estereoscópica, con una cámara incorporada y un software. Las partes fueron soldadas empleando un pro- cedimiento diferente para cada grupo. Las correspondientes al Grupo I se invistieron en un block refractario a base de sílico-fosfato. Las del Grupo II se montaron en una estructu- ra metálica Clever Spider. El desajuste fue mensurado y los resultados procesados estadísticamente. El nivel de significa- ción fue establecido en p<0,05. Resultados: El Grupo I tuvo un desajuste inicial de 97,30±13,81µm y el Grupo II de 98,53±11,24µm. Luego de la soldadura, el Grupo I registró 98,53±17,17µm, 1,23µm mayor respecto al inicial. En el Grupo II se observó 103,13±17,61µm, 4,60µm por encima del original. Se analizaron mediante prue- ba t de Student; en ambos casos el resultado fue de p>0,05. Al comparar entre sí los grupos I y II, por medio de la prueba t y de comprobación no paramétrica de Mann-Whitney, se ob- servaron diferencias no significativas, p=0,41 y p=0,38 res- pectivamente (AU)


Aim: Compare two conventional welding procedures us- ing a Cr-Co alloy, to connect sectioned cast bars to be fixed on implants. Materials and methods: From a master model representing a toothless jaw with four implants, twenty (n=20) specimens sectioned into three parts were made. Two groups were formed, each with ten (n=10) specimens. Once conditioned, they were screwed to the master mod- el. Its initial mismatch was analyzed using a stereoscop- ic magnifier, with a built-in camera and a software. The parts were welded using a different procedure for each group. Those corresponding to Group I were invested in a refractory block based on silyl-phosphate. Those of Group II were mounted on a Clever Spider metal structure. The mismatch was measured, and the results processed statisti- cally. The level of significance was established at p<0.05. Results: Group I had an initial mismatch of 97.30 ±13.81µm, and Group II of 98.53±11.24µm. After welding, Group I registered 98.53±17.17µm, 1.23µm higher than the initial one. In Group II, 103.13±17.61µm was observed, 4.60µm above the original. They were analyzed using Stu- dent's t test; in both cases the result was p>0.05. When com- paring groups I and II, using the t-test and the Mann-Whitney nonparametric verification, non-significant differences were observed, p=0.41 and p=0.38 respectively. Conclusions: Under the conditions of this study, it was ob- served that the two welding methods analyzed were reliable for joining metallic superstructures without affecting their final fit (AU)


Assuntos
Soldagem em Odontologia , Retenção em Prótese Dentária/métodos , Ajuste de Prótese/métodos , Prótese Dentária Fixada por Implante/métodos , Interpretação Estatística de Dados , Ligas de Cromo/síntese química , Revestimento de Dentadura
9.
Artigo em Inglês | MEDLINE | ID: mdl-37623201

RESUMO

BACKGROUND: The COVID-19 pandemic has promoted a shortage of filtering facepiece respirators (FFRs) and the emergence of new FFRs brands. We aimed to determine the fit provided by in-use FFRs in Peruvian healthcare workers (HCWs) during the COVID-19 pandemic. METHODS: We enrolled 279 HCWs from 37 primary healthcare centers with highest burden of care for TB in Peru, of which 263 were assessed using quantitative fit tests (QNFT). Results were expressed as real-time fit factor (rt-FF) and overall fit factor (overall-FF), which was categorized as ≥100 (optimal result), 50-99, and <50. RESULTS: We identified 3M 1860 FFRs (33.1%), Xiantao Zhong Yi ZYB-11 FFRs (24.6%) and Makrite 9500 FFRs (20.5%), mainly. Eighty-seven FFRs (33.1%) had an optimal overall-FF, 27 (10.3%) between 50-99, and 149 (56.6%) less than 50. Of the 87 FFRs with optimal overall-FF, 73 (83.9%) were 3M 1860 FFRs. Of the 27 FFRs with overall-FF between 50-99, 7 (25.9%) were Makrite 9500, while of the 149 with overall-FF less than 50, 58 (38.9%), and 47 (31.5%) were Xiantao Zhong Yi ZYB-11 and Makrite 9500, respectively. CONCLUSION: Xiantao Zhong Yi and Makrite FFRs do not adapt adequately to the face of Peruvian HCWs, most having fit factors less than 50.


Assuntos
COVID-19 , Tuberculose , Humanos , Peru/epidemiologia , Pandemias/prevenção & controle , Pessoal de Saúde , Ventiladores Mecânicos
10.
J Prosthodont ; 2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37470305

RESUMO

PURPOSE: To evaluate the vertical misfit, stress distribution around dental implants, and cantilever fracture strength of 3-unit implant-supported cantilever fixed partial dentures (FPDs) using frameworks made from different materials and manufacturing techniques. MATERIALS AND METHODS: Forty FPDs were fabricated and divided into 5 groups (n = 8) based on the framework material used: LAS Co-Cr (Conventional casting-laser welding); TIG Co-Cr (Conventional casting -TIG welding); OP Co-Cr (Conventional casting-one-piece); CAD Co-Cr (CAD-CAM); and CAD Zr (CAD-CAM ZrO2 ). The vertical misfit was evaluated before porcelain application (T1) and before (T2), and after thermomechanical cycling (T3) by stereomicroscopy. Cantilever fracture strength was tested with a 50 kN (5000 kgf) load cell at a crosshead speed of 0.5 mm/min. Qualitative and quantitative photoelastic analysis was performed to evaluate stress distribution at seven specific points in five FPDs (n = 1/group) subjected to occlusal loading. RESULTS: Only the molar showed interaction among the three factors (G × S × T; F(20.932) = 1.630; p = 0.044). Thermomechanical cycling (T2 vs. T3) had a significant effect on intra-group vertical misfit in molar, especially in LAS Co-Cr (Δ = 5.87; p = 0.018) and OP Co-Cr (Δ = 5.39; p = 0.007), with no significant effect in premolar (p > 0.05). Ceramic application combined with thermomechanical cycling (T1 vs. T3) caused a significant intra-group increase in vertical misfit in all groups, both in the molar and premolar (p < 0.05). OP Co-Cr was associated with greater vertical misfit and stress concentration. Frameworks manufactured by the CAD-CAM system exhibited lower vertical misfit and better stress distribution. FPDs with metal frameworks (>410.83 ± 72.26 N) showed significantly higher fracture strength (p < 0.05) than zirconia (277.47 ± 39.10 N), and the first signs of ceramic veneering fracture were observed around 900 N. CONCLUSIONS: FPDs with frameworks manufactured using a CAD-CAM system appear to be associated with lower vertical misfit and better stress distribution, although the section of the frameworks followed by welding may be a viable alternative. In addition, metal frameworks exhibit high fracture strength.

11.
Plant Biol (Stuttg) ; 25(5): 671-680, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37164339

RESUMO

Flower morphology is considered an important factor in species diversification because it may influence the efficiency of pollination in different ways (e.g. attraction and mechanical fit with different groups of pollinators). In the present study, we quantified the variation in flower morphology (i.e. shape and size) of the diverse South American genus Jaborosa Juss. (Solanaceae) in relation to contrasting pollination modes: rewarding pollination either by moths or by generalist small insects versus brood-site deceptive pollination by saprophilous flies. We examined variations of flower morphology in frontal (pollinator attraction) and sagittal (functional fit with pollinators) views in 12 Jaborosa species using geometric morphometric methods and comparative approaches to infer whether flower shape evolution, not attributable to flower allometry or phylogenetic relationship, is associated with shifts in pollination modes. We found remarkable variation in flower morphology among both Jaborosa species and pollination modes, largely in sagittal view. Evolutionary trends in shape of fly-pollinated flowers were mainly attributable to changes in developmental trajectories. Variation in flower architecture facilitated differential pollen placement - on the proboscis of moths, and either on the back or ventral region of saprophilous flies - promoting diversification of the genus. Diversification of shape, independent of size, in most of the studied Jaborosa species would indicate adaptation to contrasting pollination modes.


Assuntos
Dípteros , Mariposas , Solanaceae , Animais , Filogenia , Evolução Biológica , Polinização , Flores/anatomia & histologia
12.
Front Psychol ; 14: 1088183, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36910791

RESUMO

The objective of this study was to understand how gig-workers interpret the effects of their laboral activity on their wellbeing. We developed a grounded theory based on interviews with 57 Brazilian gig-workers. The results show that (1) workers and gig-work organizations have preferences for work relationships with more autonomy or security; (2) when there is a congruence of preferences, the worker experiences greater wellbeing, and when the preferences diverge, there are episodes of preference violations that, when repeated, reduce worker wellbeing; and (3) however, not everything is a matter of fit: when both individuals and organizations have the same preference (for example, for more autonomy and less security), worker wellbeing may be vulnerable to abuse, for example, in terms of an unsustainable workload. Our study draws attention to an integrated discussion of the benefits and harms of algorithmic management, which allows overcoming a polarized view in which it would be seen only as beneficial or harmful to workers.

13.
Anticancer Res ; 43(4): 1569-1580, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36974786

RESUMO

BACKGROUND/AIM: This study assessed the diagnostic accuracy (DA) of fecal immunochemical test (FIT) ColonView (CV) and guaiac-based fecal occult blood test (HemoccultSENSA) among bleed-positive (history or signs of intestinal bleeding) and bleed-negative participants (no history or signs of intestinal bleeding) (n=5,090) in colorectal neoplasia (CRN) screening in Brazil. PATIENTS AND METHODS: The eligible patients for the study (n=506) collected three consecutive stool samples, to be analyzed by both assays (CV, SENSA). Finally, 421/5090 (8.3%) patients returned both samples, which were subjected to final analysis. Receiver operating characteristic (ROC) analysis with different cut-offs was performed to assess the DA. RESULTS: The area under curve (AUC) values for i) visually analyzed (VA) CV for bleed-positive CRC, ii) automatically analyzed (AA) CV for bleed-positive CRC, iii) VA CV for bleed-negative CRC, and iv) AA CV for bleed-negative CRC as endpoints were as follows: i) AUC=0.864, ii) AUC=0.933, iii) AUC=0.836, and iv) AUC=0.892. In roccomp analysis, the differences in AUC values were: between i) and ii) p=0.068; between i) and iii) p=0.497; between i) and iv) p=0.488; between ii) and iii) p=0.0058; between ii) and iv) p=0.229; and between iii) and iv) p=0.138. CONCLUSION: This is the first investigation where two modes of CV test, VA, and AA, for bleed-positive and bleed-negative CRC patients were used as the endpoint. The AA reading of the CV test showed higher DA in bleed-positive than in bleed-negative CRC patients.


Assuntos
Neoplasias Colorretais , Sangue Oculto , Humanos , Brasil , Detecção Precoce de Câncer , Neoplasias Colorretais/complicações , Neoplasias Colorretais/diagnóstico , Fezes , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Colonoscopia
14.
Neuroscience ; 511: 39-52, 2023 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-36156289

RESUMO

Cannabinoids regulate analgesia, which has aroused much interest in identifying new pharmacological therapies in the management of refractory pain. Voltage-gated Na+ channels (Navs) play an important role in inflammatory and neuropathic pain. In particular, Nav1.9 is involved in nociception and the understanding of its pharmacology has lagged behind because it is difficult to express in heterologous systems. Here, we utilized the chimeric channel hNav1.9_C4, that comprises the extracellular and transmembrane domains of hNav1.9, co-expressed with the ß1 subunit on CHO-K1 cells to characterize the electrophysiological effects of ACEA, a synthetic surrogate of the endogenous cannabinoid anandamide. ACEA induced a tonic block, decelerated the fast inactivation, markedly shifted steady-state inactivation in the hyperpolarized direction, decreasing the window current and showed use-dependent block, with a high affinity for the inactivated state (ki = 0.84 µM). Thus, we argue that ACEA possess a local anaesthetic-like profile. To provide a mechanistic understanding of its mode of action at the molecular level, we combined induced fit docking with Monte Carlo simulations and electrostatic complementarity. In agreement with the experimental evidence, our computer simulations revealed that ACEA binds Tyr1599 of the local anaesthetics binding site of the hNav1.9, contacting residues that bind cannabinol (CBD) in the NavMs channel. ACEA adopted a conformation remarkably similar to the crystallographic conformation of anandamide on a non-homologous protein, obstructing the Na+ permeation pathway below the selectivity filter to occupy a highly conserved binding pocket at the intracellular side. These results describe a mechanism of action, possibly involved in cannabinoid analgesia.


Assuntos
Ácidos Araquidônicos , Canabinoides , Humanos , Ácidos Araquidônicos/farmacologia , Canais de Sódio , Dor , Anestésicos Locais , Bloqueadores dos Canais de Sódio/farmacologia
15.
Braz. dent. j ; Braz. dent. j;34(6): 91-99, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1528030

RESUMO

Abstract The purpose of this study was to evaluate and measure the microleakage inhibiting quality of provisional restorations manufactured using computer-aided manufacturing, 3D printing, and chairside molded provisional restorative materials. Fifteen provisional restorations each from 3D printed, milled, and chairside molded were manufactured. All restorations were cemented onto sintered zirconia abutment dies and adhered with zinc-oxide non-eugenol temporary cement. Artificial aging was conducted by thermocycling for 800 cycles to simulate 1 month of clinical use. All specimens were submerged in 2% (w/w) methylene blue for 24 hours at 37°C, sectioned, and analyzed digitally for the distance of dye penetration through image analysis. The data were analyzed using the Kruskal-Wallis test with Dunn-Bonferroni post-hoc. Significant differences in dye penetration depth were observed between all groups except milled vs chairside molded. Light microscopy revealed differences in mean cement thickness for 3D printed, milled, and chairside molded of 83.6 µm (1σ = 31.9 µm), 149.1 µm (1σ = 88.7 µm) and 137.9 µm (1σ = 67.2 µm) respectively. Conclusion: 3D printed provisional restorations were found to have the least amount of microleakage compared to milled and chairside molded provisional restorations.


Resumo O objetivo deste estudo foi avaliar e medir a qualidade de inibição de microinfiltração de restaurações provisórias fabricadas usando manufatura assistida por computador, impressão 3D e materiais de restauração provisória moldados no consultório. Foram fabricadas 15 restaurações provisórias impressas em 3D, fresadas e moldadas em consultório. Todas as restaurações foram cimentadas em matrizes de pilar de zircônia sinterizada e aderidas com cimento temporário de óxido de zinco sem eugenol. O envelhecimento artificial foi conduzido por termociclagem por 800 ciclos para simular 1 mês de uso clínico. Todos os espécimes foram submersos em azul de metileno a 2% (p/p) por 24 horas a 37°C, seccionados e analisados digitalmente quanto à distância de penetração do corante por meio de análise de imagem. Os dados foram analisados usando o teste de Kruskal-Wallis com post-hoc de Dunn-Bonferroni. Foram observadas diferenças significativas na profundidade de penetração do corante entre todos os grupos, exceto entre fresado e moldado na cadeira. A microscopia óptica revelou diferenças na espessura média do cimento para as restaurações impressas em 3D, fresadas e moldadas em cadeira de 83,6 µm (1σ = 31,9 µm), 149,1 µm (1σ = 88,7 µm) e 137,9 µm (1σ = 67,2 µm), respectivamente. Conclusão: As restaurações provisórias impressas em 3D apresentaram a menor quantidade de microinfiltração em comparação com as restaurações provisórias fresadas e moldadas no consultório.

16.
Saudi Dent J ; 34(8): 708-714, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36570575

RESUMO

Objective: This study aimed to investigate the influence of periodontal status, clinical data, and serum markers on salivary leptin levels in patients with systemic lupus erythematosus (SLE). Methods: A case-control study was conducted with 38 patients with SLE and 29 healthy controls. Periodontal data included periodontal probing depth (PPD), clinical attachment level (CAL), and gingival bleeding on probing (BOP). Stimulated saliva samples were collected to analyze salivary leptin levels. Clinical and serum data were collected from the SLE group. Statistical analysis included the t-test, Mann-Whitney test, Spearman correlation coefficient, and a structural equation model. Results: The SLE group had a lower salivary leptin level than the control group (P = 0.002). The model revealed that SLE had an inverse and independent effect on salivary leptin (standardized estimate =  - 0.289, P = 0.023). Moreover, salivary leptin level negatively correlated with the serum levels of triglyceride, creatinine, and leukocytes, positively correlated with the serum total cholesterol, but was not significantly correlated with the periodontal status. Conclusion: These findings suggest that patients with SLE have a lower salivary leptin level. In addition, the level of salivary leptin does not appear to be related to periodontal status in patients with SLE.

17.
Rev. CES psicol ; 15(3): 154-165, sep.-dic. 2022. tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1406723

RESUMO

Resumen La fusión de identidad consiste en un sentimiento de unión con un grupo, en el que el individuo experimenta una mezcla entre su identidad personal y la social; y es un buen predictor de la conducta extrema progrupo. El presente estudio analizó la estructura factorial de la Escala verbal de fusión de identidad elaborada por Gómez et al. (2011), en una muestra chilena. Se utilizó una muestra universitaria seleccionada por conveniencia de 411 participantes (66% mujeres) con una edad media de 24.45 años (DT = 5.89). Se analizó el ajuste unifactorial y bifactorial de la Escala a través del análisis factorial, y las respectivas confiabilidades. Los resultados indicaron un buen y mejor ajuste del modelo bifactorial (χ 2/gl = 3.34, p < .001, CFI = .975, TLI = .957, SRMR = .030, y RMSEA = .085), por sobre el unifactorial, que no mostró un buen ajuste (χ 2/gl = 5.26, p < .001, CFI = .946, TLI = .919, SRMR = .042, y RMSEA = .116). Ambos modelos contaron con altas confiabilidades (> .800). Se discutió sobre el mejor ajuste de la estructura bifactorial en relación con estudios realizados en Estados Unidos, España y población inmigrante en Chile. Se proyecta la necesidad de futuros estudios que incorporen otros análisis de validez y superen la limitación del presente estudio asociada al uso de una muestra no representativa.


Abstract Identity fusion consists in a form alignment with a group and is a significant predictor of extreme pro-group behavior. The present study analyzed the factor structure of the verbal scale of identity fusion developed by Gómez et al. (2011), in a Chilean sample. A Chilean university sample by convenience of 411 participants (66% women) with a mean age of 24.45 years (SD = 5.89) was used. One-factor and two-factor fit of the scale was analyzed through factor analysis, and the respective reliabilities. The results indicated a good and better fit of the two-factor (χ2/gl = 3.34, p < .001, CFI = .975, TLI = .957, SRMR = .030, and RMSEA = .085), than the one-factor model, which did not show a good fit (χ2/gl = 5.26, p < .001, CFI = .946, TLI = .919, SRMR = .042, and RMSEA = .116). Both models had high reliabilities (> .800). The better fit of the two-factor structure was discussed in relation to studies conducted in the United States, Spain, and an immigrant population in Chile. The need for future studies incorporating other validity analyses and overcoming the limitation of the present study associated with the use of a non-representative sample is projected.

18.
Suma psicol ; 29(2)dic. 2022.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1536886

RESUMO

Introduction: The COVID-19 pandemic has had a very negative impact on people's overall mental health and psychosocial well-being, but the study of available social support to cope with such an adverse situation has received hardly any attention. Objective: To examine the psychometric properties of the MOS Perceived Social Support Questionnaire among the Mexican population in the context of the COVID-19 pandemic. Method: Non-experimental cross-sectional study. A sociodemographic questionnaire and the Medical Outcomes Study were applied in a non-probabilistic sample. A total of 898 people from different regions in Mexico, 258 males and 640 females, participated in the study in the context of the COVID-19 pandemic. Results: The analysis yielded a bi-factor model with two factors, Emotional/informational support and Tangible support, with satisfactory goodness of fit indices. Reliability was adequate with a high hierarchical omega coefficient, as well as in the factors. Likewise, the H coefficient was adequate in the general factor and its dimensions. Conclusions: Results showed that the scale is a valid and reliable measure of perceived social support among the Mexican population.


Introducción: La pandemia de COVID-19 ha tenido un impacto muy negativo en la salud mental y el bienestar psicosocial general de las personas, pero el estudio del apoyo social disponible para hacer frente a una situación tan adversa como esta ha recibido muy poca atención. Objetivo: Examinar las propiedades psicométricas del Cuestionario MOS de Apoyo Social Percibido en población mexicana en contexto de pandemia por COVID-19. Método: Diseño no experimental transversal. Se aplicó un cuestionario sociodemográfico y el Medical Outcomes Study en una muestra no probabilística por conveniencia. Participaron 898 personas de diferentes regiones de México, 258 hombres y 640 mujeres, durante el contexto de la pandemia por COVID-19. Resultados: El análisis arrojó un modelo Bi-factor de dos factores Apoyo emocional/ informacional y Apoyo tangible, con índices de bondad que se ajustaron a los datos. La fiabilidad fue adecuada con un coeficiente de omega jerárquico alto, así como en los factores. Asimismo, el coeficiente H fue adecuado en el factor general y sus dimensiones. Conclusiones: La escala presenta validez y confiabilidad para medir el apoyo social percibido en población mexicana.

19.
Odovtos (En línea) ; 24(3)dic. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1406160

RESUMO

Abstract A 3-dimensional (3D) printed custom-frame can improve the peripheral seal of readily available surgical/medical masks. This study aimed to assess the acceptance of a 3D-printed custom-frame with the American Society for Testing and Materials (ASTM) surgical/medical masks and the use of a face shield. A total of 206 subjects from a dental school participated, who answered a multiple-choice questionnaire. Participants received an invitation through the institutional email of the school via Qualtrics platform. 3D printed custom-frames were fabricated for each participant. According to their response, participants were divided into 4 groups: mask only (M), mask and frame (MF), mask and face shield (MFS), and all 3 personal protective equipment (MFFS). Data was analyzed in absolute and relative frequency. The acceptance of a 3D-printed custom-frame in the group MFFS varied between ''poor''/''very poor'' (44.7%). It allowed ''good'' performance of routine procedures (40.3%), but ''poor'' visual quality (48.1%). Musculoskeletal tolerance and ease to perform movements were adequate. There was no interference in olfactory sensitivity (44.7%) or in the ability to breathe (34.5%). Finally, it showed "moderate pain" (48.1%) on the ear and "no pain" (38.9%) on the head. The 3D-printed custom-frame adapted to ASTM surgical/medical face masks showed reasonable tolerance. Side effects of ear pain ranging in degrees were noted. Further research is indicated to evaluate safety, comfort, compliance, side effects, and occupational hazards of long-term use of enhanced PPE recommendations.Avoiding the recurrent outbreaks of COVID-19, the use of PPE by the public is necessary. Improper PPE use is a major source of concern for human and environmental health. Preventing such activities can be done by following steps involved in PPE disposals or by getting a new way to re-use such as improving peripherical sealing. Our work highlights that a custom-frame can improve protection, without adverse effects.


Resumen El sellado periférico de las máscaras médicas/quirúrgicas puede ser mejorado fácilmente mediante un marco personalizado impreso en 3 dimensiones (3D). Este estudio tuvo como objetivo evaluar la aceptación de un marco personalizado impreso en 3D cuando usado en combinacion con máscaras médicas/quirúrgicas de la Sociedad Estadounidense para Pruebas y Materiales (ASTM) asi como con el uso de protector facial. Participaron un total de 206 sujetos de una facultad de odontología, quienes respondieron un cuestionario de opción múltiple. Los participantes recibieron una invitación a través del correo institucional de la escuela a través de la plataforma Qualtrics. Se fabricaron marcos personalizados impresos en 3D para cada participante. Según su respuesta, los participantes se dividieron en 4 grupos: solo máscara (M), máscara y marco (MF), máscara y protector facial (MFS) y los 3 equipos de protección personal (MFFS). Los datos se analizaron en frecuencia absoluta y relativa. La aceptación de un marco personalizado impreso en 3D en el grupo MFFS varió entre ''pobre''/''muy pobre'' (44,7%). Permitió un ''buen'' desempeño de los procedimientos de rutina (40,3%), pero una ''mala'' calidad visual (48,1%). La tolerancia musculoesquelética y la facilidad para realizar movimientos fueron adecuadas. No hubo interferencia en la sensibilidad olfativa (44,7%) ni en la capacidad de respirar (34,5%). Finalmente, mostró "dolor moderado" (48,1%) en el oído y "sin dolor" (38,9%) en la cabeza. El marco personalizado impreso en 3D adaptado a las máscaras faciales quirúrgicas/ médicas de ASTM mostró una tolerancia razonable. Se observaron efectos secundarios de dolor de oído que variaron en grados. Estudios futuros deben evaluar la seguridad, la comodidad, efectos secundarios y los riesgos laborales del uso a largo plazo para este tipo de combinación. Para evitar los brotes recurrentes de COVID-19, es necesario el uso de equipamento personal de protección (EPP) por parte del público. El uso inadecuado de EPP es una fuente importante de preocupación para la salud humana y ambiental. La prevención de tales actividades se puede hacer siguiendo los pasos involucrados en la eliminación de EPP o obteniendo una nueva forma de reutilización, como mejorar el sellado periférico. Nuestro trabajo resalta que un marco personalizado puede mejorar la proteccion, sin afectos adversos.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Impressão Tridimensional/instrumentação , Equipamento de Proteção Individual , Máscaras , COVID-19/prevenção & controle
20.
Braz. dent. j ; Braz. dent. j;33(6): 121-128, Nov.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1420554

RESUMO

Abstract This study aimed to evaluate the internal adaptation of three different computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic crowns. The internal adaptation of a polymer-infiltrated ceramic network material (Vita Enamic [VE]) was compared to two machinable glass-ceramics; Zirconia-reinforced lithium silicate (Vita Suprinity [VS]) and a lithium disilicate glass-ceramic (IPS e.max. CAD). Thirty human premolars of average size were prepared (n=10 each group) by computer numerical control to fulfill the criteria of all-ceramic crown design. Optical impressions were taken for each tooth preparation using the CAD/CAM scanner. Thirty crowns were fabricated using CAD/CAM system and divided into three groups (IPS e.max, VE, and VS). To assess the internal fit of tested crowns, the gap between the intaglio of each crown and the corresponding tooth surface was evaluated using a 3D digital scanner using the Triple-scan Protocol. One-way ANOVA followed by Tukey Post Hoc statistical tests were used to statistically analyze results of the internal fit. There was a statistically significant difference for all groups at the four axial walls (p = 0.000002). For total internal fit between groups, comparisons showed a statistically significant difference between all tested groups (p=0.000002). When each pair of groups was statistically compared with each other, all pair comparisons showed a statistically significant difference. IPS e.max CAD had the best internal fit, followed by Vita Enamic, then Vita Suprinity. For all ceramics tested, values of internal fit of all ceramics tested were within the clinically acceptable range.


Resumo Este estudo teve como objetivo avaliar a adaptação interna de três diferentes coroas cerâmicas CAD/CAM (Computer-aided design/computer-aided manufacturing). A adaptação interna de um material cerâmico de rede com infiltração de polímero (Vita Enamic [VE]) foi comparada com duas cerâmicas de vidro maquináveis; silicato de lítio reforçado com zircónio (Vita Suprinity [VS]) e uma cerâmica-vidro de dissilicato de lítio (IPS e.max. CAD). Trinta dentes pré-molares humanos de tamanho médio foram preparados (n=10 cada grupo) por controle numérico computadorizado para preencher os critérios de desenho de coroa em cerâmica pura. Foram tiradas impressões ópticas para cada preparação dentária utilizando o scanner CAD/CAM. Trinta coroas foram fabricadas usando o sistema CAD/CAM e divididas em três grupos (IPS e.max, VE, e VS). Para avaliar o ajuste interno das coroas testadas, o espaço entre o entalhe de cada coroa e a superfície dentária correspondente foi avaliado usando um scanner digital 3D usando o Protocolo Triple-scan. Para analisar estatisticamente os resultados do ajuste interno, utilizou-se a ANOVA unidirecional seguida dos testes estatísticos Tukey Post Hoc. Houve uma diferença estatisticamente significativa para todos os grupos nas quatro paredes axiais (p = 0,000002). Para o ajuste interno total entre grupos, as comparações mostraram uma diferença estatisticamente significativa entre todos os grupos testados (p=0,000002). Quando cada par de grupos foi comparado estatisticamente uns com os outros, todas as comparações de pares mostraram uma diferença estatisticamente significativa. IPS e.max CAD teve o melhor ajuste interno, seguido por Vita Enamic, depois Vita Suprinity. Para todas as cerâmicas testadas, os valores de ajuste interno de todas as cerâmicas testadas encontravam-se dentro da gama clinicamente aceitável.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA