RESUMO
Abstract Mirror foot is a rare congenital anomaly within the spectrum of complex polydactyly of the foot. It can occur alone or with other malformations or genetic syndromes. It is a little described topic in the literature, with few publications on its treatment. We report the case of a 4-year-old female patient who presented eight fingers on her left foot and no other associated deformities. Her complaints included the impossibility of wearing closed shoes and social stigma. Radiography revealed eight metatarsals with their respective phalanges, five cuneiform bones, and the absence of bone deformities in the hindfoot. We opted for a surgical approach aiming at functional and esthetic improvement, in addition to better adaptation to closed shoes, as desired by the patient and her family. We performed a dorsal and plantar "V" incision and resected three supernumerary rays, including three central metatarsals with their nine corresponding phalanges, two cuneiform bones, tendons, and excess digital nerves. Next, we sutured the intermetatarsal ligaments, preserving the fingers with a normal appearance, reducing the width of the foot, and preserving adequate support. Kirschner wires maintained the reduction by transmetatarsal fixation. During the postoperative period, the patient wore a boot splint with zero load with no complications. We removed the Kirschner wires and allowed load on the limb after 12 weeks.
Resumo O pé em espelho é uma anomalia congênita rara, pertencente ao espectro das polidactilias complexas dos pés. Pode ocorrer isoladamente ou associado a outras malformações ou síndromes genéticas. Trata-se de um tema pouco descrito na literatura, com escassas publicações acerca do seu tratamento. Relatamos o caso de uma paciente do sexo feminino, de 4 anos de idade, que apresentava pé esquerdo com 8 dedos, sem outras deformidades associadas, cuja queixa incluía impossibilidade do uso de calçados fechados e estigma social. Radiograficamente, verificou-se a presença de oito metatarsos com suas respectivas falanges, cinco ossos cuneiformes e ausência de deformidades ósseas no retropé. Optou-se pela abordagem cirúrgica visando uma melhoria funcional e estética, bem como melhor adaptação ao uso de calçados fechados, conforme desejo da paciente e de sua família. Foi realizada incisão em "V" dorsal e plantar com ressecção de três raios supranumerários, incluindo três metatarsos centrais com suas nove falanges correspondentes, dois ossos cuneiformes, tendões e nervos digitais excedentes, seguida da sutura dos ligamentos intermeta-tarsais, com preservação dos dedos com aparência normal, diminuição da largura do pé e manutenção do seu apoio adequado. A redução foi mantida por fixação transmetatarsal com fios de Kirschner. O pós-operatório seguiu com o uso de tala bota e carga zero, sem intercorrências; os fios de Kirschner foram retirados, e a carga no membro foi liberada após 12 semanas.
RESUMO
Abstract The most frequent skeletal injuries are hand fractures, which constitute around 20% of all fractures. Fractures of the phalanx are usual, comprising 6% of all fractures. Proximal phalanx fractures arise more often. The main goals of the care are to repair the anatomy, reduce the damage to soft tissue, and mobilize the damaged fingers as soon as stabilization of the fracture allows it. The present report is intended to examine the clinical and radiation effects of proximal phalanx fractures in patients treated with intramedullary screw fixation who underwent closed reduction. We report three consecutive cases of proximal phalanx fracture: two basal fractures and one simple shaft fracture. They were treated surgically with closed reduction with intramedullary headless compression screws. The preoperative magnitude of the angulation of the proximal phalanx averaged 30.3° (range: 13° to 42°). Two patients presented rotational deformity. The clinical findings were measured using the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (Quick-DASH) questionnaire, and the range of motion and functional results were assessed. Complications were observed over a span of at least 3 months. The patients displayed complete active flexion-extension proximal interphalangeal joint and flexion-extension metacarpophalangeal joint without rotative deformity. The scores on the QuickDASH were satisfactory (mean: 2.3; range: 0 to 4.5). No secondary surgeries were performed, and complications were not observed. Intramedullary fixation of proximal phalanx fractures with cannulated tension screws has been shown to be a safe operation, resulting in outstanding functional performance and an early recovery. The fracture is minimized and properly consolidated by the patients.
Resumo As lesões esqueléticas mais frequentes são as fraturas que ocorrem nas mãos, que representam aproximadamente 20% de todas as fraturas. As mais comuns são as fraturas falangeanas, que abrangem 6% de todas as fraturas. As fraturas da falange proximal aparecem com mais frequência. O principal objetivo do atendimento é corrigir a anatomia, reduzir os danos aos tecidos moles, e mobilizar os dedos atingidos assim que a estabilização da fratura permitir. Este relato tem como objetivo examinar os efeitos clínicos e da radiação nas fraturas da falange proximal, em pacientes infectados com a fixação de parafuso intramedular que foram submetidos a redução fechada. Este é o relato de três casos consecutivos de fratura da falange: duas fraturas da base e uma fratura simples da diáfise. Todos foram submetidos a redução fechada com parafuso intramedular de compressão sem cabeça. A magnitude pré-operatória da angulação da falange proximal foi em média 30,3° (variação de 13° a 42°). Dois pacientes apresentaram deformidade rotacional. Os achados clínicos foram medidos com a versão abreviada do questionário de Disfunções do Braço, Ombro e Mão (Quick Disabilities of the Arm, Shoulder and Hand, QuickDash, em inglês), em que foram avaliados a amplitude de movimento e os resultados funcionais. Complicações foram observadas em um período mínimo de 3 meses. Os pacientes apresentavam flexo-extensão ativa total na articulação interfalangiana proximal e na articulação metacarpofalangiana de flexo-extensão sem deformidade rotacional. A pontuação no Quick-DASH foi satisfatória (média: 2,3; variação: 0 a 4,5). Não houve cirurgias secundárias, e não se observaram complicações. A fixação intramedular das fraturas da falange proximal com o parafuso de tensão canulado tem se mostrado uma cirurgia segura, com excelente desempenho funcional e recuperação precoce. A fratura é minimizada e consolidada adequadamente pelos pacientes.
RESUMO
Abstract Objective To compare the use of cannulated screws and smooth Kirschner wires in terms of reducing the presence of exuberant callus and complications in pediatric displaced fractures of the lateral humeral condyle. Methods An analytical cross-sectional study of consecutive cases was conducted from May to October 2021 with 30 children with displaced external humeral condyle fractures. The functional results regarding pain and range of motion were stratified using the Dhillon grading system. Results A total of 19 patients underwent Kirschner wire fixation, and 11 underwent cannulated screw fixation. Closed fixation was performed in 14 cases (47%), and open fixation, in 16 (53%). Of the cases included, there was no loss to follow-up. Te sample was composed of 21 (70%) male patients, and the age ranged from 5 to 15 years, with a mean of 6.96 years. The most frequent cause of fracture was fall from height (50%), which was related to greater displacement on baseline radiographs. Complications that were not related to the reduction approach or the implant used were observed in 12 (40%) cases. Conclusion The present study shows no benefits in relation to the use of smooth pins or cannulated screws to reduce the presence of exuberant callus in the consolidation of the fracture. We see that the complications that arise are related to the severity of the injury, and benefits cannot be identified in the choice of one implant over another. We could see that the Weiss classification helps to define the behavior in favor of open or closed reduction without interfering in kindness of the smooth pin or the cannulated screw for fracture fixation.
Resumo Objetivo Comparar o uso de parafusos canulados e de fios de Kirschner lisos em termos da redução da presença de calo exuberante e de complicações em fraturas pediátricas deslocadas do côndilo lateral do úmero. Métodos Um estudo analítico transversal de casos consecutivos foi realizado de maio a outubro de 2021 com 30 crianças com fraturas deslocadas de côndilo umeral externo. Os resultados funcionais para dor e amplitude de movimento foram estratificados utilizando o sistema de classificação Dhillon. Resultados Ao todo, 19 pacientes foram submetidos à fixação de fio Kirschner, e 11 à fixação de parafusos canulados. A fixação realizada foi fechada em 14 casos (47%) e aberta em 16 (53%). Dos casos incluídos, não houve perda no acompanhamento. A amostra continha 21 (70%) pacientes do sexo masculino, e a idade variou de 5 a 15 anos, com média de 6,96 anos. A causa mais frequente de fratura foi queda de altura (50%), e esteve relacionada ao maior deslocamento nas radiografias da linha de base. Complicações que não estavam relacionadas à abordagem de redução ou ao implante utilizado foram observadas em 12 (40%) casos. Conclusão Este estudo não mostra benefícios em relação ao uso de pinos lisos ou de parafusos canulados para reduzir a presença de calo exuberante na consolidação da fratura. Vemos que as complicações que surgem estão relacionadas à gravidade da lesão, e não é possível identificar benefícios na escolha de um implante ou outro. Pudemos ver que a classificação de Weiss ajuda a definir o comportamento em favor da redução aberta ou fechada sem dar preferência ao pino liso ou ao parafuso canulado para a fixação da fratura.
Assuntos
Humanos , Criança , Adolescente , Parafusos Ósseos , Fios Ortopédicos , Lesões no Cotovelo , Fraturas do Úmero/cirurgiaRESUMO
ABSTRACT Introduction Fractures of the distal third of the forearm are common in the pediatric population. Conservative treatment of an ipsilateral fracture of the distal ulna metaphysis is one of the risk factors for loss of reduction. Percutaneous fixation of the fracture with K-wires is recommended. This study aims to evaluate the outcome of percutaneous fixation of both bones performed as the primary treatment. Materials and Methods A randomized, open, prospective, clinical trial was conducted, including skeletally immature patients who underwent surgery for fractures of the distal radius and ulna. They were randomized into two groups, one with fixation only of the radius fracture and the other with fixation of both the radius and the ulna fractures, and they were followed clinically and radiologically for up to 12 weeks postoperatively. Results Sixteen children were selected. In the intraoperative period, fluoroscopy was activated for a longer time when fixing the ulna (p = 0.011) and the surgical time was longer in this group (p = 0.014). In the postoperative evaluations, the group whose surgery involved the fixation of both bones had a lower postoperative pain score (p <0.001) and less time away from school (p <0.001). Conclusions In this study, postoperative pain and absence from school were both less when fixation of the radius and ulna was performed. Evidence Level II; Randomized Controlled Study.
RESUMO Introdução As fraturas do terço distal do antebraço são comuns na população pediátrica. O tratamento conservador da fratura ipsilateral da metáfise distal da ulna é um dos fatores de risco para a perda da redução. Recomenda-se a fixação percutânea da fratura com fios K. Este estudo tem como objetivo avaliar o resultado da fixação percutânea de ambos os ossos realizada como tratamento primário. Materiais e Métodos Foi realizado um estudo clínico randomizado, aberto e prospectivo, que incluiu pacientes com esqueleto imaturo que foram submetidos à cirurgia para fraturas da parte distal do rádio e a ulna. Os participantes foram randomizados em dois grupos, um com fixação apenas da fratura do rádio e outro com fixação das fraturas do rádio e da ulna, e foram acompanhados clínica e radiologicamente por até 12 semanas de pós-operatório. Resultados Dezesseis crianças foram selecionadas. No intraoperatório, a fluoroscopia foi ativada por mais tempo na fixação da ulna (p = 0,011) e o tempo cirúrgico foi maior nesse grupo (p = 0,014). Nas avaliações pós-operatórias, o grupo cuja cirurgia envolveu a fixação de ambos os ossos teve escore de dor menor depois da cirurgia (p < 0,001) e menos tempo de afastamento da escola (p < 0,001). Conclusões Neste estudo, a dor pós-operatória e o afastamento da escola foram menores quando se realizou fixação do rádio e da ulna. Nível de Evidência II; Estudo randomizado controlado.
RESUMO
ABSTRACT Objective: To compare the outcomes of the fixation of complete and displaced supracondylar humeral fractures in children with two different Kirschner wire configurations. Methods: The type of fixation was randomized to either crossed (19 cases), or two divergent lateral Kirschner wires (24 cases). The comparison was made six months later between the two treated groups and each group with the non-fractured elbow (clinical alignment, range of motion, Baumann angle, and lateral humeral capitellar angle). Results: 43 children were evaluated (65% boys) with a mean age of six years and five months. The carrying angle (p = 0.94), extension (p = 0.89), and the Flynn´s criteria (p = 0.56) were similar between the groups. The flexion was slightly smaller for the crossed wire group (p = 0.04), but similar to the uninjured side. The Baumann angle was not different between the two fixations (p = 0.79) and the contralateral side (p = 0.1). The lateral humeral capitellar angle was slightly greater for the lateral pinning (p = 0.08), but with no difference with the uninjured elbow (p = 0.62). No iatrogenic injuries were observed. Conclusion: Both fixations presented similar outcomes that did not significantly affect the carrying angle in relation to the non-fractured side. Level of evidence II, Therapeutic study - Investigating the results of treatment.
RESUMO Objetivo: Comparar os resultados da fixação das fraturas supracondilianas completas e desviadas do úmero de crianças com dois tipos de configuração de fios de Kirschner. Método: O tipo de fixação foi aleatorizado para fixação com dois fios de Kirchner cruzados ou laterais divergentes. Depois de seis meses foi feita a comparação entre os dois grupos fixados entre si e cada um deles com o lado não fraturado do mesmo paciente (alinhamento clínico, arco de movimento, critérios de Flynn, ângulos de Baumann e capituloumeral). Resultados: Participaram do estudo 43 crianças (65% meninos), com idade média de seis anos e cinco meses. A extensão (p = 0,89), o ângulo de carregamento (p = 0,94) e os critérios de Flynn (p = 0,56) foram semelhantes entre os dois grupos, sem ocorrência de lesões iatrogênicas. A flexão foi discretamente menor no grupo com fios cruzados (p = 0,04), mas próximo do cotovelo normal. O ângulo de Baumann não apresentou diferença entre as duas fixações (p = 0,79), bem como com o lado não fraturado (p = 0,01). O ângulo capituloumeral foi ligeiramente maior (p = 0,08) nos fios laterais, mas sem diferença em relação lado normal (p = 0,62). Conclusão: As duas fixações apresentaram resultados similares e não alteraram significativamente o ângulo frontal do cotovelo em relação ao lado não fraturado. Nível de evidência II, Estudo terapêutico - Investigação dos resultados do tratamento.
RESUMO
Abstract The use of metal wires, called Kirschner wires, is a simple and effective fixation method for the correction of shoulder fractures and of dislocations in orthopedic surgery.Wire migration during the postoperative follow-up is a possible complication of the procedure. The authors present the case of a 48-year-old male patient, a business administrator, who suffered a fall from his own height during a soccer match resulting in right shoulder trauma. The patient was treated at a specialized orthopedics and trauma hospital and was diagnosed with a grade V acromioclavicular dislocation. Four days after the trauma, the acromioclavicular dislocation was surgically treated using ligatures with anchor wires, coracoacromial ligament transfer, and fixation with Kirshner wires from the acromion to the clavicle. At the follow-up, 12 days after the surgical procedure, migration of the Kirschner wire to the acromion edge was identified. The patient was oriented to undergo another surgery to remove the Kirshner wire, due to the possibility of further migration; nonetheless, he refused the surgery. Nine months after the surgical treatment, the patient complained of pain on the left shoulder (contralateral side), difficulty tomobilize the shoulder, ecchymosis, and protrusion. Bilateral radiographs demonstrated that the Kirschner wire, originally from the right shoulder, was on the left side. The patient then underwent a successful surgery to remove the implant.
Resumo O uso dos fios metálicos, denominados fios de Kirschner, é um método de fixação simples e eficaz para a correção de fraturas e luxações do ombro na cirurgia ortopédica. Uma das possíveis complicações é a migração do fio durante o acompanhamento pósoperatório. Os autores apresentam um caso de um paciente masculino de 48 anos, administrador, que sofreu uma queda de mesmo nível com trauma em ombro direito durante uma partida de futebol. Atendido emumhospital de referência de ortopedia e traumatologia, foi diagnosticada luxação acromioclavicular grau V. Quatro dias após o trauma, fez-se o tratamento cirúrgico da luxação acromioclavicular com amarrilhos com fios de âncora, transferência do ligamento coracoacromial e fixação com fio de Kirchner do acrômio à clavícula. No retorno, 12 dias após o procedimento cirúrgico, identificou-se amigração do fio de Kirschner do bordo do acrômio. Apesar de orientado a se submeter a cirurgia para remoção do fio, o paciente se recusou.Novemeses após o tratamento cirúrgico, o paciente apresentou dores no ombro esquerdo (lado contralateral), dificuldade para mobilizar o ombro, equimose e saliência. Foram feitas radiografias bilaterais e foi constatado que o fio de Kirschner, originalmente no ombro direito, estava no ombro contralateral. Fez-se então cirurgia para remoção do implante, com sucesso.
Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Luxação do Ombro , Articulação do Ombro , Articulação Acromioclavicular , Fios Ortopédicos , Migração de Corpo EstranhoRESUMO
Abstract Humeral shaft fractures combined with elbow dislocation and fracture of the distal third of the bones of the forearm are uncommon. No description of this simultaneous association has been found in the same patient. Some studies report the association of these two lesions; however, no reports on the three ipsilateral lesions have been found at the PubMed, Lilacs and Bireme databases. The present report describes a case that occurred in a 13-yearold boywho suffered a fall froma height of approximately threemeters andwas admitted to a trauma hospital. Radiographs showed an ipsilateral humeral shaft fracture combinedwith elbowdislocation anda fracture of thedistal-third of thebonesof the forearm.Undergeneral anesthesia, the injurieswere readily reduced by closedmanipulation, obtaininga satisfactory reduction of the injuries. Following this, an antebrachiopalmar splint and a commercial Velpeau shoulder immobilizer for the treatment of the humerus diaphyseal fracture were used. After 1 week, the patient presented non-alignment of the diaphyseal fracture of the humerus and was submitted to surgical treatment with flexible retrograde intramedullary nailing, antebrachiopalmar cast, and a commercial Velpeau shoulder immobilizer.
Resumo A fratura da diáfise do úmero associada a luxação posterolateral do cotovelo e fratura de terço distal dos ossos do antebraço é uma lesão rara, não relatada na literatura pesquisada. Alguns estudos reportam a associação de duas dessas lesões, porém não foram encontrados relatos com as três ipsilateralmente nas bases PubMed, Lilacs e Bireme. Os autores apresentam o caso de um paciente de 13 anos, do sexo masculino, comhistória de queda de aproximadamente três metros de altura. Foi atendido em um hospital terciário de referência em traumatologia com diagnóstico de fratura diafisária do úmero associada a luxação do cotovelo, lesão da placa fisária do rádio e fratura de terço distal da ulna ipisilateral esquerda. O paciente foi submetido a redução incruenta de todas as lesões sob sedação anestésica; posteriormente à redução, optou-se pelo uso de tala antebraquiopalmar e tipoia comercial tipo Velpeau como tratamento da fratura diafisária de úmero. Após uma semana, o paciente apresentou desvio da fratura diafisária do úmero, foi submetido a tratamento cirúrgico com hastes flexíveis de forma retrógrada, gesso antebraquiopalmar e tipoia comercial do tipo Velpeau.
Assuntos
Humanos , Masculino , Adolescente , Pinos Ortopédicos , Cotovelo , Fixação Interna de Fraturas , Fraturas do ÚmeroRESUMO
ABSTRACT OBJECTIVE: To define the best technique for the surgical treatment of supracondylar fracture of the humerus (SFH) in children, evaluating percutaneous pinning with side wires vs. cross-pinning. METHODS: Randomized controlled trials using the Medline, CAPES, and BIREME. The criteria for inclusion of articles criteria were: (1) randomized controlled trials (RCTs) comparing percutaneous wire fixation techniques, (2) SFH Gartland II B, III, and IV, and (3) children aged 1-14 years. The following were used as main variables: incidence of iatrogenic injury to the ulnar nerve and loss reduction. RESULTS: Eight studies were selected (521 patients) comparing surgical treatment with pinning in supracondylar fracture of the humerus in children Gartland II type B, III or IV. Iatrogenic injury to the ulnar nerve was greater with the cross-pinning technique, with RR 0.28 and p= 0.03, while the mini-open technique presented RR 0.14 and p= 0.2. A statistically significant greater loss of reduction in the lateral pinning was observed in FSU Gartland III and IV(p= 0.04). CONCLUSION: Based upon this meta-analysis of prospective randomized clinical trials, the following is recommended: (1) percutaneous pinning with lateral wires in supracondylar fractures of the humerus in children classified as Gartland II type B; (2) use of crossed wires for Gartland type III or IV, using the mini-open technique for the medial wire.
RESUMO OBJETIVO: Definir a melhor técnica para o tratamento cirúrgico da fratura supracondilar do úmero (FSU) nas crianças e avaliar a pinagem percutânea com fios laterais vs. cruzados. MÉTODOS: Revisão de ensaios clínicos randomizados nas bases de dados Medline, Capes, Bireme. Os critérios de inclusão dos artigos foram: (1) Ensaios clínicos randomizados que comparam técnicas de fixação percutânea com fios, (2) FSU Gartland II tipo B, III e IV e (3) Crianças com um a 14 anos. Usamos como principais variáveis: incidência de lesão iatrogênica do nervo ulnar e perda da redução. RESULTADOS: Foram selecionados oito estudos (521 pacientes) que comparam tratamento cirúrgico com pinagem em fratura supracondilar do úmero em crianças classificadas como Gartland II tipo B, III ou IV. A lesão iatrogênica do nervo ulnar foi maior com a técnica de pinagem cruzada, apresentou RR 0,28 e p = 0,03, enquanto que na técnica de mini-open encontraram-se RR 0,14 e p = 0,2. Em casos de FSU Gartland III e IV, evidenciou-se maior perda da redução na pinagem lateral, com significância estatística (p = 0,04). CONCLUSÃO: Embasado em nossa metanálise com ensaios clínicos randomizados prospectivos, recomendamos: (1) pinagem percutânea com fios laterais em fraturas supracondilar do úmero em crianças classificadas como Gartland II tipo B (2) Uso de fios cruzados para fraturas Gartland tipo III ou IV, com a técnica de mini-open para o fio medial.
Assuntos
Feminino , Lactente , Pré-Escolar , Criança , Adolescente , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas do ÚmeroRESUMO
ABSTRACT CONTEXT: Hardware breakage during hip surgery can pose challenging and difficult problems for orthopedic surgeons. Apart from technical difficulties relating to retrieval of the broken hardware, complications such as adjacent joint arthritis and damage to neurovascular structures and major viscera can occur. Complications occurring during the perioperative period must be informed to the patient and proper documentation is essential. The treatment options must be discussed with the patient and relatives and the implant company must be informed about this untoward incident. CASE REPORT: We report a case of complete removal of the implant and then removal of the broken guidewire using a combination of techniques, including a cannulated drill bit, pituitary forceps and Kerrison rongeur. CONCLUSIONS: We suggest some treatment options and recommendations for preventing an avoidable surgical catastrophe.
RESUMO CONTEXTO: Ruptura de material de síntese durante a cirurgia de quadril pode representar problemas desafiadores e difíceis para cirurgiões ortopédicos. Além de dificuldades técnicas com recuperação do material quebrado, complicações como artrite na articulação adjacente, danos às estruturas neurovasculares e às principais vísceras podem ocorrer. A complicação durante o período perioperatório deve ser informada ao paciente e documentação apropriada é essencial. As opções de tratamento devem ser discutidas com o paciente e seus familiares e a empresa do implante deve ser informada sobre este incidente desagradável. RELATO DE CASO: Nós relatamos um caso da remoção completa do implante e, em seguida, a remoção do fio-guia quebrado usando uma combinação de técnicas, incluindo uma broca canulada, fórceps da hipófise e rongeur de Kerrison. CONCLUSÕES: Sugerimos algumas opções de tratamento e recomendações para prevenir uma evitável catástrofe cirúrgica.
Assuntos
Idoso , Feminino , Humanos , Fios Ortopédicos , Remoção de Dispositivo/métodos , Fraturas do Quadril/cirurgia , Articulação do Quadril/cirurgia , Complicações Intraoperatórias/cirurgia , Pinos Ortopédicos , Parafusos Ósseos , Falha de Equipamento , Complicações Intraoperatórias/prevenção & controle , Falha de TratamentoRESUMO
OBJECTIVE: to demonstrate a surgical technique for treating neck fractures of the fifth metacarpal, by means of reduction through intra-focal manipulation and percutaneous fixation using Kirschner wires, with the aims of making it easier to achieve and maintain the reduction during the operation and enabling reduction of these fractures even if a fibrous callus has formed. METHODS: a series of ten patients with neck fractures of the fifth metacarpal presenting palmar angles greater than 30◦ underwent the surgical technique described, as examples, and their results were evaluated through postoperative radiographs and clinical examinations. RESULTS: all the patients achieved reductions that were close to anatomical and evolved to consolidation of the fracture in the position obtained. CONCLUSION: the surgical technique described is effective, easy to carry out, minimally invasive and low-cost, thereby enabling adequate clinical and radiographic reduction, even in subacute fractures already presenting a fibrous callus...
OBJETIVO: demonstrar uma técnica cirúrgica para o tratamento das fraturas do colo do quinto metacarpo por meio de redução por manipulação intrafocal e fixação percutânea com fios de Kirschner, visando a facilitar a obtenção e manutenção da redução no intraoperatório e possibilitar a redução dessas fraturas, ainda que com calo fibroso formado. MÉTODOS: dez pacientes portadores de fratura do colo do quinto metacarpo com angulação palmar superior a 30◦ foram submetidos, como exemplos, à técnica cirúrgica descrita. Os resultados foram avaliados por meio de radiografias e exame clínico pós-operatório. RESULTADOS: todos os pacientes obtiveram redução próxima da anatômica e evoluíram para consolidação da fratura na posição obtida. CONCLUSÃO: a técnica cirúrgica descrita é eficaz, de simples execução, minimamente invasiva, de baixo custo e permite redução clínica e radiográfica adequadas, mesmo em fraturas subagudas com calo fibroso formado...
Assuntos
Humanos , Masculino , Adolescente , Adulto Jovem , Fraturas Ósseas , Fios Ortopédicos , Metacarpo/cirurgia , Metacarpo/lesões , Extremidade SuperiorRESUMO
As fraturas de platô tibial são relativamente raras e representam, aproximadamente, 1,2% de todas as fraturas. A tíbia, por sua localização subcutânea e pobre cobertura muscular, está exposta a sofrer grandes quantidades de traumatismos, que não são somente fraturas, mas também lesões por achatamento, contusões severas, entre outras que, em um determinado momento, podem causar no enfermo a síndrome compartimental. É relatado o caso de um paciente de 58 anos que, após fratura de platô tibial, apresentou síndrome compartimental de perna e foi submetido à fasciotomia descompressiva dos quatro compartimentos direitos. Após osteossíntese com fixação interna de platô tibial com placa em L, evoluiu com nova síndrome compartimental.
Fractures of the tibial plateau are relatively rare, representing around 1.2% of all fractures. The tibia, due to its subcutaneous location and poor muscle coverage, is exposed and suffers large numbers of traumas, not only fractures, but also crush injuries and severe bruising, among others, which at any given moment, could lead compartment syndrome in the patient. The case is reported of a 58-year-old patient who, following a tibial plateau fracture, presented compartment syndrome of the leg and was submitted to decompressive fasciotomy of the four right compartments. After osteosynthesis with internal fixation of the tibial plateau using an L-plate, the patient again developed compartment syndrome.
Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas da TíbiaRESUMO
OBJETIVO: Analisar e apresentar os resultados de fraturas supracondilianas instáveis de úmero em crianças, tratadas cirurgicamente com redução e fixação percutânea com dois fios de Kirschner cruzados. MÉTODOS: Foi realizado estudo transversal com 20 crianças, considerando sexo, idade na época da fratura e no momento da análise, lateralidade, tipo e mecanismo de fratura, complicações pós-operatórias, variáveis radiográficas e clínicas. RESULTADOS: Observaram-se 10 fraturas à esquerda e 10 à direita. A idade na fratura variou de dois a 13 anos (média 5,9 anos ± 2,48). Três fraturas foram classificadas como tipo II e 17 do tipo III. O tempo de seguimento variou de quatro meses a três anos. O ângulo de Baumann variou de 69 a 100 (média 78,3), sendo observada a presença de cúbito varo em quatro pacientes (com valores variando de 84 a 100). Segundo os critérios de Flynn modificados, obtiveram-se 20 casos satisfatórios, 17 excelentes (85%), dois bons (10%) e um regular (5%). Dois pacientes apresentaram déficit da amplitude de movimento, dois parestesia no território cubital e uma criança apresentou neuropraxia transitória do nervo ulnar por seis semanas. CONCLUSÃO: A fixação percutânea com dois fios de Kirschner cruzados, quando realizada com visualização direta e isolamento do nervo ulnar, permite bons resultados.
OBJECTIVE: To analyze and present the surgical results from unstable supracondylar fractures of the humerus in children, treated by means of reduction and percutaneous fixation using two crossed Kirschner wires. METHODS: A cross-sectional study was conducted on 20 children, taking into consideration sex, age at the time of the fracture, age at the time of the assessment, side affected, type and mechanism of trauma, postoperative complications and radiographic and clinic variables. RESULTS: Ten fractures were observed in the left arm and ten in the right arm. The age at the time of the fracture ranged from 2 to 13 years (mean: 5.9 ± 2.48 years). Three fractures were classified as type II and 17 as type III. The length of follow-up ranged from four months to three years. Baumann's angle ranged from 69 to 100 (mean: 78.3) and cubitus varus was observed in four patients (values ranging from 84 to 100). According to the modified Flynn's criteria, 20 cases presented satisfactory outcomes: 17 excellent (85%), two good (10%) and one regular (5%). Two patients presented limited range of motion, two had paresthesia in the cubital region and one had transient neuropraxia of the ulnar nerve for six weeks. CONCLUSION: Percutaneous fixation with two crossed Kirschner wires leads to good results when carried out under direct viewing and with isolation of the ulnar nerve.
Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Fios Ortopédicos , Fixação de Fratura , Fraturas do Úmero/cirurgiaRESUMO
A migração de pinos e hastes metálicas ortopédicos para a cavidade torácica é rara e pouco descrita na literatura médica, embora seja potencialmente fatal, principalmente quando atingem o coração ou grandes vasos intratorácicos. Reportamos um caso de migração de fio de Kirschner, implantado na clavícula direita há 10 anos, transfixando a aorta torácica em sua porção ascendente, sendo retirado por toracotomia póstero-lateral esquerda.
The orthopedic metallic pins and wires migration for the chest cavity is uncommon and rarely reported in medical literature although it is potentially lethal, especially when they reach the heart or mediastinum great vessels. We reported a case of Kirschner wire withdrawal, for right postero-lateral thoracotomy, which were transfixanting ascendent thoracic aorta artery, in its due to its migration of left clavicle, where it was placed to fix an occurred fracture 10 years before.
Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Fios Ortopédicos , Migração de Corpo Estranho/complicações , Fixação Interna de Fraturas/instrumentação , Artérias Torácicas/lesões , Clavícula/lesões , Migração de Corpo Estranho/cirurgia , Fraturas Ósseas/cirurgia , Artérias Torácicas/cirurgiaRESUMO
OBJETIVOS: Durante o tratamento de fraturas fechadas do colo do metacarpo do dedo mínimo (fraturas do boxeador) usando fixação percutânea com fio K transversal e outros procedimentos, pode ocorrer lesão iatrogênica do ramo digital dorsal do dedo mínimo (RDDDM) do ramo dorsal do nervo ulnar (RDNU). Neste estudo, visamos descrever a relação do RDDDM do RDNU e os pontos de inserção na face lateral do quinto metacarpo durante fixação percutânea com fio K transversal de fraturas subcapitais. MÉTODOS: Foram realizadas dissecações e medições desse ramo depois de colocação de pino transversal percutâneo na parte distal do quinto osso do metacarpo em dez mãos de cadáveres fixadas em formalina. RESULTADOS: Os resultados desse estudo confirmam a grande proximidade da trajetória do pino e desse ramo, e demonstram sua possível lesão iatrogênica durante a fixação do fio K no quinto metacarpo. CONCLUSÕES: Para evitar a penetração desse nervo e limitar as chances de lesão iatrogênica, é importante conhecer o trajeto desse nervo. Os autores descrevem os pontos de inserção anatômica e acreditam que com uso do conhecimento da anatomia das fraturas subcapitais do quinto metacarpo, elas podem ser tratadas sem risco de déficits sensoriais futuros.
OBJECTIVES: When treating closed fractures of the neck of the little finger metacarpal (boxer fractures) with percutaneous transverse K-wire fixation and other procedures, there may be iatrogenic injury to the dorsal digital branch to the little finger (DDBLF) of the dorsal branch of the ulnar nerve (DBUN . In this study we aimed to describe the relationship of the DDBLF of the DBUN and the insertion points on the external side of the fifth metacarpal during percutaneous transverse K-wire fixation of subcapital fractures. METHODS: Dissections and measurements regarding this branch were performed after percutaneous transverse pinning to distal part of fifth metacarpal bones in ten cadaver hands formalin fixed. RESULTS: The results of this study confirm the close proximity of the trajectory of the with this branch and demonstrate its potential iatrogenic injury during K-wire fixation of the fifth metacarpal. CONCLUSIONS: To avoid penetration of this nerve and limit the chances of iatrogenic injury it is important to know its course. The authors describe the anatomical insertion points and believe that using the anatomical knowledge, subcapital fifth metacarpal fractures can be treated without risk of sensory deficits.
Assuntos
Humanos , Pessoa de Meia-Idade , Pinos Ortopédicos , Fraturas Ósseas , Fixação Intramedular de Fraturas/métodos , Metacarpo/lesões , Cadáver , Traumatismos da MãoRESUMO
OBJETIVO: Demonstrar uma opção simples e eficaz para o tratamento das fraturas da extremidade distal do rádio com o uso de fios de Kirschner. MÉTODOS: No período de setembro de 2008 a abril de 2009, foram tratados, cirurgicamente, 48 pacientes com fraturas da extremidade distal do rádio classificadas como A3 pela classificação AO, usando uma modificação da técnica de Kapandji. RESULTADOS: Dos 48 punhos operados, 42 (87,5 por cento) apresentaram mensurações pós-operatórias dentro dos limites considerados adequados. Utilizamos os parâmetros de McQuenn e Caspers, que consideram uma angulação radial maior que 19º e uma angulação volar menor que -12º. Todas as medidas de inclinação volar do rádio pós-operatórias estiveram abaixo de -3º. O valor da inclinação radial pré-operatória média era de 13,14º e a medida pós-operatória foi de 21,18º. O valor médio da inclinação volar pré-operatória era 28,75º e a mensuração da inclinação volar pós-operatória era 3,31º. A média da altura radial pré-operatória era 5,25mm e a medida pós-operatória foi 9,48mm. CONCLUSÃO: A técnica descrita tem excelente estabilidade para o tratamento das fraturas da extremidade distal do rádio classificadas como A3, é de fácil execução, minimamente invasiva, com mínimas complicações cirúrgicas e é de baixo custo.
OBJECTIVE: To demonstrate a simple and efficacious option for treating fractures of the distal extremity of the radius using Kirschner wires. METHODS: Between September 2008 and April 2009, 48 patients with fractures of the distal extremity of the radius, classified as A3 according to the AO classification, were treated surgically using a modification of the Kapandji technique. RESULTS: Out of the 48 wrists operated, 42 (87.5 percent) presented postoperative measurements within the acceptable limits. We used the parameters of McQuenn and Caspers who considered that the radial angulation should be wider than 19° and the volar angulation should be narrower than -12°. All the postoperative volar inclination measurements were narrower than -3°. The mean preoperative radial inclination was 13.14° and the mean postoperative value was 21.18°. The mean preoperative volar inclination was 28.75° and the mean postoperative value was 3.31°. The mean preoperative radial height was 5.25 mm and the mean postoperative value was 9.48 mm. CONCLUSION: The technique described here had excellent stability for treating fractures of the distal extremity of the radius classified as A3. It was easy to implement and minimally invasive, with minimal surgical complications, and it was inexpensive.
Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Fios Ortopédicos , Fraturas do Rádio/cirurgia , Fraturas do RádioRESUMO
OBJETIVO: Avaliar a relação entre lesões abdominais e a introdução de fios guia em ensaios cirúrgicos do quadril, propor um sistema de escorização e conduta médica em função da distância percorrida pelo fio guia a partir da placa quadrilátera e a estrutura anatômica lesionada. MATERIAL E MÉTODOS: Utilizou-se 18 quadris de cadáveres, um fio de Steimann de 3.2 x 300 mm, um perfurador elétrico e um paquímetro. Introduziu-se o fio no centro do colo femoral por via de acesso lateral no quadril sob visualização direta. Por via de acesso abdominal mediana longitudinal estendida à região pélvica, observou-se a placa quadrilátera até o fio a transfixar. A partir deste ponto, prolongou-se a inserção por mais 140 mm, a fim de observar seu trajeto abdominal e descrever as lesões apresentadas em função da distância percorrida. RESULTADOS: Houve cinco (27 por cento) lesões de cólon sigmóide e uma (5 por cento) lesão transfixante do nervo obturador. Artérias e veias ilíacas comuns contra laterais ao quadril fixado não foram lesionadas. CONCLUSÃO: O fio guia não deve ultrapassar a placa quadrilátera. Medidas de prevenção são importantes no pré e intra-operatório e o escore e a conduta médica propostos neste estudo devem ser criteriosamente observados nos casos de lesão comprovada.
OBJECTIVES: Evaluate the relationship between abdominal injuries and the introduction of guide wire in experimental hip surgery, to propose a scoring system and a medical management based on the distance traveled by the guide wire from the quadrilateral plate until the damaged anatomical structure. MATERIAL AND METHODS: 18 cadaveric hips, a Steimann pin of 3.2 x 300mm, an electric drill and a caliper were used. The wire was inserted in the center of the femoral neck through a lateral approach in the hip under direct visualization. Via median abdominal extended approach to the pelvic region, the quadrilateral plate was observed until the wire crossed it. From this point the wire was further inserted 140 mm in order to observe its abdominal path and describe the lesions presented based on the distance traveled. RESULTS: There were five lesions (27 percent) in the sigmoid colon, and one transfixing injury (5 percent) of the obturator nerve. The common iliac arteries and veins from the contralateral hip were not injured. CONCLUSION: The guide wire must not exceed the quadrilateral plate. Preventive measures are important in the pre- and intra-operatory stages and the score and medical management proposed in this study should be carefully observed in cases of injury.
Assuntos
Humanos , Adulto , Fios Ortopédicos , Colo Sigmoide/lesões , Fios Ortopédicos/efeitos adversos , Fraturas do Quadril , Nervo Obturador , Traumatismos Abdominais/etiologia , Traumatismos Abdominais , Cadáver , Traumatismos Abdominais/reabilitaçãoRESUMO
OBJETIVO: Analisar a resistência final suportada por dois tipos de fio e pela interface âncora-fio em três diferentes implantes tipo âncora submetidos à tração contínua, com o propósito de indicar o mais apropriado para sutura de estruturas como o manguito rotador do ombro. MÉTODOS: Os testes foram feitos em três grupos: grupo 1 - parafuso âncora de titânio com fio Ethibond® #2; grupo 2 - parafuso âncora de titânio com fio Fiber Wire® #2; e grupo 3 - parafuso âncora de titânio 5,0mm Corkscrew®. RESULTADOS: No grupo 1, a carga máxima média até a soltura foi de 124,5 newtons (N), sendo a mínima de 105N e a máxima de 180N, com variação de 75N entre os dois extremos e desvio-padrão de 23,03N. No grupo 2, a carga máxima média até a soltura foi de 298N, mínima de 230N, máxima de 375N, com variação de 145N e desvio-padrão de 44,73N. No grupo 3, foi obtida a maior carga máxima média, sendo esta de 272N, a mínima de 205N e a máxima de 340N, com variação de 135N. A análise estatística demonstrou diferença significativa entre as médias de cargas resistidas entre os grupos 1 x 2 e 1 x 3 (p < 0,001). CONCLUSÃO: Observou-se semelhança na resistência final obtida com o fio Fiber Wire® independentemente da âncora usada. O fio Ethibond #2 apresentou resistência inferior, menor que a desejada para a sutura de estruturas como do manguito rotador do ombro.
OBJECTIVE: To analyze the final strength withstood by two types of suture threads and by the anchor-suture interface in three different anchor implants submitted to continuous traction for the purpose of choosing the most appropriate to suture structures such as the shoulder rotator cuff. METHOD: Tests were performed in three groups: Group 1 - titanium anchor screw with Ethibond® #2 suture, Group 2 - titanium anchor screw with Fiber Wire® #2 suture, and Group 3 - Corkscrew® 5.0 mm anchor screw. RESULTS: In Group 1, mean maximum load till loosening was 124.5 124,5 Newtons (N), the minimum load was 105 N, and the maximum load was 180 N, with a range of 75 N between the two extremes, and standard deviation of 23.03 N. In Group 2, the mean maximum load till loosening was 298 N, the minimum load was 230 N, the maximum load was 375 N, with a range of 145 N, and standard deviation of 44.73 N. In Group 3, the highest mean maximum load was measured, of 272 N, the minimum load was 205 N, and the maximum load of 340 N, with a range of 135 N. Statistical analysis showed a significant difference between the mean loads withstood between groups 1 and 2, and between groups 1 and 3, (p < 0.001). CONCLUSION: Final strength was similar with Fiber Wire® suture irrespective of the anchor used. Ethibond #2 suture showed lower strength, lower than that desired to suture structures such as the shoulder rotator cuff.
Assuntos
Humanos , Fios Ortopédicos , Manguito Rotador/cirurgia , Técnicas de SuturaRESUMO
OBJETIVO: Determinar o risco de lesão do nervo sensitivo radial após fixação percutânea na região distal do rádio em cadáveres. MÉTODOS: Foram utilizados 24 membros superiores de 12 cadáveres esqueleticamente maduros, 10 do sexo masculino e dois do feminino, com média de idade estimada de 50 anos. Um fio de Kirschner foi introduzido no processo estilóide do rádio para determinar: a distância entre o fio e o nervo sensitivo radial, entre o fio e o ramo do nervo dorsal mais próximo, entre o fio e os tendões do primeiro túnel osteofibroso e, finalmente, o número de ramos do nervo sensitivo radial. RESULTADOS: A distância do ponto de emergência do nervo sensitivo radial, entre os tendões e o fio de Kirschner aplicado no processo do rádio, foi em média de 5,09cm, com desvio-padrão de 0,75cm. A distância entre o fio de Kirschner e o primeiro ramo dorsal foi em média de 4,33cm, variando entre zero e 10cm. O número de ramos nervosos foi em média de quatro, variando entre dois a oito ramos. CONCLUSÃO: Os resultados deste estudo experimental indicaram que, quando o fio é introduzido no processo estilóide do rádio, o risco de lesão do nervo sensitivo radial é pequeno. Esse risco está diretamente relacionado com o número de ramos nervosos e a angulação dos fios durante sua introdução na extremidade distal do rádio.
OBJECTIVE: To establish the risk of lesion to the radial sensory nerve after percutaneous fixation in the distal radius region of cadavers. METHODS: The authors used 24 upper limbs of 12 skeletally mature cadavers, 10 male, and 2 female, mean age estimated as 50 years. A Kirschner wire was introduced in the styloid process of the radius to make the following determinations: distance between the wire and the radial sensory nerve, between the wire and the closest dorsal nerve branch, between the wire and the tendons of the first osteofibrous tunnel, and, finally, the number of branches of the radial sensory nerve. RESULTS: The site were the nerve appeared, between the two tendons and the Kirschner wire in the radial styloid process was a mean 5.09 cm, with a standard deviation of 0.75 cm. The distance between the Kirschner wire and the first dorsal branch was a mean 4.33 cm, ranging from zero to 10 cm. The number of nervous branches was a mean of four, ranging from two to eight branches. CONCLUSION: Results of this experimental study showed that when the wire is introduced in the styloid process of the radius, the risk of lesioning the radial sensory nerve is not a big risk. This risk is directly related to the number of nervous branches and to the angles of the wires while they are being introduced in the distal end of the radius.