Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(9)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38732959

RESUMO

For most patients admitted to a hospital, it is a requirement to continuously monitor their vital signs. Among these are the waveforms from ECG and the pulmonary arterial pulse. At present, there are several electronic devices that can measure the arterial pulse waveform. However, they can be affected by electromagnetic wave radiation, and the fabrication of electronic sensors is complicated and contributes to the e-waste, among other problems. In this paper, we propose an optical method to measure arterial pulse based on a Fabry-Perot interferometer composed of two mirrors. A pulse sensor formed by an acrylic cell with a thin membrane is used to gather the vasodilatation of the wrist, forming an air pulse that is enacted by means of a tube to a metallic cell containing a mirror that is glued to a thin silicone membrane. When the air pulse arrives, a displacement of the mirror takes place and produces a shift of the interference pattern fringes given by the Fabry-Perot. A detector samples the fringe intensity. With this method, an arterial pulse waveform is obtained. We characterize this optical device as a test of concept, and its application to measuring artery pulse is presented. The optical device is compared to other electronic devices.

2.
Sensors (Basel) ; 23(21)2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37960484

RESUMO

The finite element method (FEM) was used to investigate the optical-mechanical behavior of a Fabry-Perot Interferometer (FPI) composed of a capillary segment spliced between two sections of standard optical fiber. The developed FEM model was validated by comparing it with theory and with previously published experimental data. The model was then used to show that the absolute strain on the host substrate is usually smaller than the strain measurement obtained with the sensor. Finally, the FEM model was used to propose a cavity geometry that can be produced with repeatability and that yields the correct absolute strain experienced by the host substrate, without requiring previous strain calibration.

3.
Sensors (Basel) ; 23(14)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37514786

RESUMO

This paper describes the use of an optical instrument, the Fabry-Perot interferometer, adapted to measure very low pressures. The interferometer consists of two high-reflectance flat mirrors placed one in front of another. In addition, a metallic chamber contains air or a gas. In one of the faces of the chamber, a flexible thin silicone membrane is attached and, over it, one of the mirrors is glued. The other mirror rests in a fixed mechanical mounting. Light crosses both mirrors and, when it leaves them, forms an interference pattern consisting of concentric circular fringes. When the pressure is increased/decreased within the chamber, a displacement of the fringes is observed due to the movement of the glued mirror. By measuring the fringe displacement and knowing the pressure, a calibration plot can be made. Minimum pressure measurements of about tens of Pascals were achieved.

4.
Polymers (Basel) ; 15(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38231976

RESUMO

Temperature measuring is a daily procedure carried out worldwide in practically all environments of human activity, but it takes particular relevance in industrial, scientific, medical, and food processing and production areas. The characteristics and performance of the temperature sensors required for such a large universe of applications have opened the opportunity for a comprehensive range of technologies and architectures capable of fulfilling the sensitivity, resolution, dynamic range, and response time demanded. In this work, a highly sensitive fiber optic temperature sensor based on a double-cavity Fabry-Perot interferometer (DCFPI) is proposed and demonstrated. Taking advantage of the Vernier effect, we demonstrate that it is possible to improve the temperature sensitivity exhibited by the polymer-capped fiber Fabry-Perot interferometer (PCFPI) up to 39.8 nm/°C. The DCFPI is sturdy, reconfigured, and simple to fabricate, consisting of a semi-spherical polymer cap added to the surface of the ferrule of a commercial single-mode fiber connector (SMF FC/PC) placed in front of a mirror at a proper distance. The length of the air cavity (Lair) was adjusted to equal the thickness of the polymer cap (Lpol) plus a distance δ to generate the most convenient Vernier effect spectrum. The DCFPI was packaged in a machined, movable mount that allows the adjustment of the air cavity length easily but also protects the polymer cap and simplifies the manipulation of the sensor head.

5.
Sensors (Basel) ; 22(17)2022 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-36080789

RESUMO

This work presents a novel methodology to implement a fuzzy inference system (FIS) to overcome the measurement ambiguity that is typically observed in interferometric sensors. This ambiguity occurs when the measurand is determined by tracing the wavelength position of a peak or dip of a spectral fringe. Consequently, the sensor measurement range is typically limited to the equivalent of 1 free spectral range (FSR). Here, it is demonstrated that by using the proposed methodology, the measurement range of this type of sensor can be widened several times by overcoming the ambiguity over some FSR periods. Furthermore, in order to support the viability of the methodology, it was applied to a couple of temperature interferometric sensors. Finally, experimental results demonstrated that it was possible to quintuple the measurement range of one of the tested sensors with a mean absolute error of MAE = 0.0045 °C, while for the second sensor, the measurement range was doubled with an MAE = 0.0073 °C.

6.
Sensors (Basel) ; 20(2)2020 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-31941162

RESUMO

Interferometry sensors are frequently analyzed by applying the Fourier transform because the transformation separates all frequency components of its signal, making its study on a complex plane feasible. In this work, we study the relation between the optical path difference (OPD) and poles location theoretically and experimentally, using the Laplace transform and a pole-zero map. Theory and experiments are in concordance. For our study, only the cosine function was considered, which is filtered from the interference pattern. In experimental work, two unperturbed low-finesse Fabry-Pérot interferometers were used. First, a Fabry-Pérot interferometer that has a cavity length of ~1.6 mm was used. Its optical path difference was 2.33 mm and the poles were localized at points ±i12. rad/nm. Secondly, a Fabry-Pérot interferometer with a cavity length of ~5.2 mm was used, and its optical path difference was 7.59 mm and the poles were localized at points ±i40.4 rad/nm. Experimental results confirmed the theoretical analysis. Our proposal finds practical application for interferometer analysis, signal processing of optical fiber sensors, communication system analysis, and multiplexing systems based on interferometers.

7.
Sensors (Basel) ; 17(10)2017 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-29065518

RESUMO

Fiber Bragg gratings are widely used optical fiber sensors for measuring temperature and/or mechanical strain. Nevertheless, the high cost of the interrogation systems is the most important drawback for their large commercial application. In this work, an in-line Fabry-Perot interferometer based edge filter is explored in the interrogation of fiber Bragg grating dynamic measurements up to 5 kHz. Two devices an accelerometer and an arterial pulse wave probe were interrogated with the developed approach and the results were compared with a commercial interrogation monitor. The data obtained with the edge filter are in agreement with the commercial device, with a maximum RMSE of 0.05 being able to meet the requirements of the measurements. Resolutions of 3.6 pm and 2.4 pm were obtained, using the optical accelerometer and the arterial pulse wave probe, respectively.

8.
Sensors (Basel) ; 17(4)2017 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-28420083

RESUMO

The application of the sensor optical fibers in the areas of scientific instrumentation and industrial instrumentation is very attractive due to its numerous advantages. In the industry of civil engineering for example, quasi-distributed sensors made with optical fiber are used for reliable strain and temperature measurements. Here, a quasi-distributed sensor in the frequency domain is discussed. The sensor consists of a series of low-finesse Fabry-Perot interferometers where each Fabry-Perot interferometer acts as a local sensor. Fabry-Perot interferometers are formed by pairs of identical low reflective Bragg gratings imprinted in a single mode fiber. All interferometer sensors have different cavity length, provoking frequency-domain multiplexing. The optical signal represents the superposition of all interference patterns which can be decomposed using the Fourier transform. The frequency spectrum was analyzed and sensor's properties were defined. Following that, a quasi-distributed sensor was numerically simulated. Our sensor simulation considers sensor properties, signal processing, noise system, and instrumentation. The numerical results show the behavior of resolution vs. signal-to-noise ratio. From our results, the Fabry-Perot sensor has high resolution and low resolution. Both resolutions are conceivable because the Fourier Domain Phase Analysis (FDPA) algorithm elaborates two evaluations of Bragg wavelength shift.

9.
Sensors (Basel) ; 15(10): 26128-42, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26501277

RESUMO

In this work a refractive index sensor based on a combination of the non-dispersive sensing (NDS) and the Tunable Laser Spectroscopy (TLS) principles is presented. Here, in order to have one reference and one measurement channel a single-beam dual-path configuration is used for implementing the NDS principle. These channels are monitored with a couple of identical optical detectors which are correlated to calculate the overall sensor response, called here the depth of modulation. It is shown that this is useful to minimize drifting errors due to source power variations. Furthermore, a comprehensive analysis of a refractive index sensing setup, based on an intrinsic micro Fabry-Perot Interferometer (FPI) is described. Here, the changes over the FPI pattern as the exit refractive index is varied are analytically modelled by using the characteristic matrix method. Additionally, our simulated results are supported by experimental measurements which are also provided. Finally it is shown that by using this principle a simple refractive index sensor with a resolution in the order of 2.15 × 10(-4) RIU can be implemented by using a couple of standard and low cost photodetectors.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Interferometria/instrumentação , Refratometria/instrumentação , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA