Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Polymers (Basel) ; 16(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38257043

RESUMO

Additive manufacturing has garnered significant attention as a versatile method for fabricating green and complex composite materials. This study delves into the fabrication of polymer composites by employing polylactic acid (PLA) in conjunction with rice husk as a reinforcing filler. The filaments were made by an extruded filament maker and then were used to make tensile and impact samples by another extrusion technology, fused deposition modeling (FDM). The structural and morphological characteristics of the composite materials were analyzed using scanning electron microscopy SEM. Results show that both the filament and samples are very reliable in producing polymer parts with this rice husk solid waste. This research contributes to increasing materials' circularity and potentially creating a local social economy around rice production, where this waste is not much used.

2.
Pharmaceutics ; 16(1)2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38258088

RESUMO

This work aimed to develop a three-dimensional (3D) wearable drug-loaded earring tap to treat affections caused by aesthetic perforations. The initial phase involved a combination of polymers to prepare filaments for fused deposition modeling (FDM) 3D printing using a centroid mixture design. Optimized filament compositions were used in the second phase to produce 3D printed earring taps containing the anti-inflammatory naringenin. Next, samples were assessed via physicochemical assays followed by in vitro skin permeation studies with porcine ear skin. Two filament compositions were selected for the study's second phase: one to accelerate drug release and another with slow drug dissolution. Both filaments demonstrated chemical compatibility and amorphous behavior. The use of the polymer blend to enhance printability has been confirmed by rheological analysis. The 3D devices facilitated naringenin skin penetration, improving drug recovery from the skin's most superficial layer (3D device A) or inner layers (3D device B). Furthermore, the devices significantly decreased transdermal drug delivery compared to the control containing the free drug. Thus, the resulting systems are promising for producing 3D printed earring taps with topical drug delivery and reinforcing the feasibility of patient-centered drug administration through wearable devices.

3.
Odovtos (En línea) ; 25(2)ago. 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1448737

RESUMO

The objective is to determine which biopolymer has the best 3D printing characteristics and mechanical properties for the manufacture of a bioscaffold, using the fused deposition printing technique, with models generated from an STL file obtained from a Micro-CT scan taken from a bovine iliac crest bone structure. Through an experimental exploratory study, three study groups of the analyzed biopolymers were carried out with thirteen printed structures of each one. The first is made of 100% PLA. The second, 90B, we added 1g of diatom extract, and the third, 88C, differs from the previous one in that it also contains 1g of calcium phosphate. The 39 printed structures underwent a visual inspection test, which required the fabrication of a gold standard scaffold in resin, with greater detail and similarity to the scanned bone structure. Finally, the structures were subjected to a compressive force (N) to obtain the modulus of elasticity (MPa) and compressive strength (MPa) of each one of them. A statistically significant difference (p=0.001) was obtained in the printing properties of the biomaterial 88C, compared to 90B and pure PLA and the 88C presented the best 3D printing characteristics. In addition, it also presented the best mechanical properties compared to the other groups of materials. Although the difference between these was not statistically significant (p=0.388), in the structures of the 88C biomaterial, values of compressive strength (8,84692 MPa) and modulus of elasticity (43,23615 MPa) were similar to those of cancellous bone in the jaws could be observed. Because of this result, the 88C biomaterial has the potential to be used in the manufacture of bioscaffolds in tissue engineering.


El objetivo es determinar cuál biopolímero presenta las mejores características de impresión 3D y propiedades mecánicas para la fabricación de un bioandamiaje, utilizando la técnica de impresión por deposición fundida, con modelos generados a partir de un archivo en formato STL que se obtuvo de un Micro-CT Scan de una estructura osea de cresta iliaca bovina. Mediante un estudio exploratorio, se realizaron 3 grupos de estudio con trece estructuras impresas de cada uno. El primero, se compone 100% de PLA. El segundo, 90B, se le agrega 1g de extracto de diatomea, y el tercero, 88C, se diferencia del anterior ya que contiene además, 1g de fosfato de calcio. A las 39 estructuras impresas se les realizó una prueba de inspección visual, por lo que se requirió la confección de un patrón de oro en resina, con mayor detalle y similitud a la estructura ósea escaneada. Finalmente, las estructuras fueron sometidas a una fuerza compresiva (N) para la obtención del módulo de elasticidad (MPa) y de la resistencia compresiva (MPa) de cada una de ellas. Se obtuvo una diferencia estadísticamente significativa (p=0,001) en las propiedades de impresión del biomaterial 88C, con respecto al 90B y al PLA puro, presentando las mejores características de impresión 3D. Además, obtuvo las mejores propiedades mecánicas en comparación con los otros grupos de materiales. Aunque la diferencia entre estos no fue estadísticamente significativa (p=0,388), en las estructuras del biomaterial 88C, se pudieron observar valores de resistencia compresiva (8,84692 MPa) y módulo de elasticidad (43,23615 MPa) que son semejantes a los del hueso esponjoso de los maxilares. A razón de este resultado, el biomaterial 88C cuenta con el potencial para ser utilizado en la fabricación de bioandamiajes en la ingeniería tisular.

4.
Micromachines (Basel) ; 13(10)2022 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-36296028

RESUMO

Modifying the natural characteristics of PLA 3D-printed models is of interest in various research areas in which 3D-printing is applied. Thus, in this study, we describe the simple impregnation of FDM 3D-printed PLA samples with well-defined silver nanoparticles and an iron metal salt. Quasi-spherical and dodecahedra silver particles were strongly attached at the channels of 3D-printed milli-fluidic reactors to demonstrate their attachment and interaction with the flow, as an example. Furthermore, Fenton-like reactions were successfully developed by an iron catalyst impregnated in 3D-printed stirrer caps to induce the degradation of a dye and showed excellent reproducibility.

5.
Talanta ; 250: 123727, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-35850056

RESUMO

Although studies have demonstrated the inactivity of hydroxychloroquine (HCQ) towards SARS-CoV-2, this compound was one of the most prescribed by medical organizations for the treatment of hospitalized patients during the coronavirus pandemic. As a result of it, HCQ has been considered as a potential emerging contaminant in aquatic environments. In this context, we propose a complete electrochemical device comprising cell and working electrode fabricated by the additive manufacture (3D-printing) technology for HCQ monitoring. For this, a 3D-printed working electrode made of a conductive PLA containing carbon black assembled in a 3D-printed cell was associated with square wave voltammetry (SWV) for the fast and sensitive determination of HCQ. After a simple surface activation procedure, the proposed 3D-printed sensor showed a linear response towards HCQ detection (0.4-7.5 µmol L-1) with a limit of detection of 0.04 µmol L-1 and precision of 2.4% (n = 10). The applicability of this device was shown to the analysis of pharmaceutical and water samples. Recovery values between 99 and 112% were achieved for tap water samples and, in addition, the obtained concentration values for pharmaceutical tablets agreed with the values obtained by spectrophotometry (UV region) at a 95% confidence level. The proposed device combined with portable instrumentation is promising for on-site HCQ detection.


Assuntos
Tratamento Farmacológico da COVID-19 , Hidroxicloroquina , Eletrodos , Humanos , Hidroxicloroquina/análise , Poliésteres , SARS-CoV-2 , Fuligem , Comprimidos/química , Água
6.
Rev. Círc. Argent. Odontol ; 80(231): 6-13, jul. 2022. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1391619

RESUMO

Este trabajo tuvo como objetivo conocer la fiabilidad de la impresora 3D (i3D) aditiva por Matriz de Proceso Digital de Luz (MDLP) Hellbot modelo Apolo®, a través de verificar la congruencia dimensional entre las mallas de modelos impresos (MMi) y su correspondiente archivo digital de origen (MMo), obtenido del software de planificación ortodontica Orchestrate 3D® (O3D). Para determinar su uso en odontología y sus posibilidades clínicas, fue comparada entre cinco i3D de manufactura aditiva, dos DLP, dos por estereolitografía (SLA) y una por Depósito de Material Fundido (FDM). La elección de las cinco i3D se fundamentó en su valor de mercado, intentando abarcar la mayor diversidad argentina disponible. Veinte modelos fueron impresos con cada i3D y escaneados con Escáner Intraoral (IOS) Carestream modelo 3600® (Cs3600). Las 120 MMi fueron importadas dentro del programa de ingeniería inversa Geomagic® Control X® (Cx) para su análisis 3D, consistiendo en la superposición de MMo con cada una de las MMi. Luego, una evaluación cualitativa de la desviación entre la MMi y MMo fue realizada. Un análisis estadístico cuidadoso fue realizado obteniendo como resultado comparaciones en 3d y 2d. Las coincidencias metrológicas en la superposición tridimensional permitieron un análisis exhaustivo y fácilmente reconocible a través de mapas colorimétricos. En el análisis bidimensional se plantearon planos referenciados dentariamente desde la MMo, para hacer coincidir las mediciones desde el mismo punto de partida dentaria. Los resultados fueron satisfactorios y muy alentadores. Las probabilidades de obtener rangos de variabilidad equivalentes a +/- 50µm fueron de un 40,35 % y de +/- 100µm un 71,04 %. Por lo tanto, te- niendo en cuenta las exigencias de congruencia dimensional clínicas de precisión y exactitud a las cuales es sometida nuestra profesión odontológica, se evitan problemas clínicos arrastrados por los errores dimensionales en la manufactura (Cam) (AU)


The objective of this study was to determine the reliability of the Hellbot Apollo® model additive 3D printer (i3D) by Matrix Digital Light Processing (MDLP) by verifying the dimensional congruence between the printed model meshes (MMi) and their corresponding digital source file (MMo), obtained from the Orchestrate 3D® (O3D) orthodontic planning software. A comparison was made between five i3D of additive manufacturing, two DLP, two by stereolithography (SLA), and one by Fused Material Deposition (FDM), to determine its use in dentistry and its clinical possibilities. The choice of the five i3D was based on their market value, trying to cover most of the Argentinean diversity available. Twenty models were printed with each i3D and scanned with Carestream Intraoral Scanner (IOS) model 3600® (Cs3600). The 120 MMi were imported into the reverse engineering program Geomagic® Control X® (Cx) for 3D analysis, consisting of overlaying MMo with each MMi. Then, a qualitative evaluation of the deviation between MMi and MMo. Also, a careful statistical analysis was performed, resulting in 3d and 2d comparisons. Metrological coincidences in three-dimensional overlay allowed a comprehensive and easily recognizable analysis through colorimetric maps. In the two-dimensional analysis, dentally referenced planes were proposed from the MMo, to match the measurements from the same dental starting point. The results were satisfactory and very encouraging. The probabilities of obtaining ranges of variability equivalent to +/- 50µm were 40.35 % and +/- 100µm 71.04 %. Therefore, considering the demands of clinical dimensional congruence, precision, and accuracy to which our dental profession it is subjected, clinical problems caused by dimensional errors in manufacturing (Cam) are avoided (AU)


Assuntos
Modelos Dentários , Impressão Tridimensional , Estereolitografia , Ortodontia/métodos , Técnicas In Vitro , Algoritmos , Software , Interpretação de Imagem Assistida por Computador/métodos , Interpretação Estatística de Dados , Estudos de Avaliação como Assunto
7.
J Mech Behav Biomed Mater ; 125: 104891, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34689030

RESUMO

Polyvinylidene fluoride - hydroxyapatite composite filaments were processed by twin-screw extrusion at different processing angular velocities and characterized by scanning electron and atomic force microscopies, differential scanning calorimetry and tensile tests. Polymer-ceramic composites with a 0-3 connectivity were successfully obtained. Regardless of the used processing parameters, all composite filaments present very similar melting (∼152°C) and solidification (∼139°C) points and elastic moduli (∼1.0 GPa) for hydroxyapatite as dispersed phase in the composite with concentrations up to 25 wt%, indicating that they are adequate for twin-screw extrusion and 3D printing. However, the yield strength (∼29 MPa), ultimate tensile strength (∼36 MPa) and tensile point (∼29 MPa) parameters are similar only for hydroxyapatite concentrations up to 15 wt%, once higher concentrations of hydroxyapatite as dispersed phase result in fragile samples (∼50% lower for each studied property).


Assuntos
Durapatita , Polivinil , Polímeros de Fluorcarboneto , Polímeros , Impressão Tridimensional
8.
Pharmaceutics ; 13(11)2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-34834360

RESUMO

3D printing has been widely used for the personalization of therapies and on-demand production of complex pharmaceutical forms. Recently, 3D printing has been explored as a tool for the development of topical dosage forms and wound dressings. Thus, this review aims to present advances related to the use of 3D printing for the development of pharmaceutical and biomedical products for topical skin applications, covering plain dressing and products for the delivery of active ingredients to the skin. Based on the data acquired, the important growth in the number of publications over the last years confirms its interest. The semisolid extrusion technique has been the most reported one, probably because it allows the use of a broad range of polymers, creating the most diverse therapeutic approaches. 3D printing has been an excellent field for customizing dressings, according to individual needs. Studies discussed here imply the use of metals, nanoparticles, drugs, natural compounds and proteins and peptides for the treatment of wound healing, acne, pain relief, and anti-wrinkle, among others. The confluence of 3D printing and topical applications has undeniable advantages, and we would like to encourage the research groups to explore this field to improve the patient's life quality, adherence and treatment efficacy.

9.
Anal Chim Acta ; 1169: 338568, 2021 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-34088376

RESUMO

3D printing is a hot topic in electroanalytical chemistry, allowing the construction of custom cells and sensors at affordable prices. In this work, we describe a novel small and practical 3D-printed electrochemical cell. The cell's body, manufactured in ABS on a 3D printer, is composed by three parts easily screwed: solution vessel, stick and cover with two embedded 3D-pen-printed carbon black-polylactic acid (CB-PLA) electrodes (counter and pseudo-reference). The cell is compatible with any planar working electrode, in which boron-doped diamond, graphite sheet (GS) and 3D-printed CB-PLA were shown as examples. A new alternative protocol to quickly produce 3D-printed sensors using a 3D pen and other low-cost apparatus is also proposed. The voltammetric performance of each evaluated sensor was carried out in the presence of redox probe ferricyanide and paracetamol as model analyte, and the surfaces were characterized by electrochemical impedance spectroscopy and scanning electrochemical microscopy. To present an analytical application of the 3D-printed cell, low-cost flexible sensors (GS and CB-PLA) were used as integrated platforms for sampling and detection of solid drugs. As a proof-of-concept, traces of drugs with a historic of counterfeit or adulteration (sildenafil citrate, tadalafil, losartan and 17α-ethinylestradiol) were abrasively sampled over the sensor and assembled on 3D-printed cell to perform a fast voltammetric scan in the presence of only 500 µL of electrolyte. This protocol is attractive for pharmaceutical and forensic sciences as a simple preliminary screening method which could identify the presence or absence of the suspicious drug as well as impurities or adulterants. The 3D-printed cell was also used for the determination of 17α-ethinylestradiol in a contraceptive pill to demonstrate a quantitative analysis. The cell is quickly printed (90 min), cheap (US$ 0.30) and requires low electrolyte volumes (0.5-3.0 mL), being suitable to be used in several other electroanalyses, especially for on-site applications.


Assuntos
Grafite , Avaliação Pré-Clínica de Medicamentos , Eletrodos , Oxirredução , Impressão Tridimensional
10.
Anal Chim Acta ; 1141: 57-62, 2021 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-33248662

RESUMO

We report in this communication a ready-to-use fused deposition modeling (FDM) based 3D-printed spectroelectrochemical cell to perform for the first time voltammetry of immobilized microparticles (VIMP) and Raman spectroscopy in situ using acrylonitrile butadiene styrene (ABS) as the filament material for printing. The 3D-printed cell was applied to evaluate solid state electrochemical behavior of tadalafil as a proof-of-concept. Several advantages were achieved in the use of the developed device, such as less manipulation of the working electrode, monitoring the same region of the solid microparticles before and after electrochemical measurements, better control of the laser incidence, low-cost and low-time production. Furthermore, the device was printed in a single-step, without handling to assembly and it has an estimated material cost of approximately 2 $. The use of 3D-printing technology was significantly important to integrate Raman spectroscopic method with VIMP measurements and to support mechanism elucidation and characterization of the compounds with less manipulation of the working electrode, avoiding loss of solid products formed from electrochemical reactions.

11.
Mater Sci Eng C Mater Biol Appl ; 114: 111013, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32993985

RESUMO

Ceramic materials such as calcium phosphates (CaPs) with a composition similar to the mineral phase of bones and polymeric polylactic acid (PLA) are potential candidates for the manufacturing of scaffolds to act as bone substitutes and for tissue engineering applications, due to their bioresorbability and biocompatibility. Variables such as porosity, topography, morphology, and mechanical properties play an essential role in the scaffolds response. In this paper, a polymer/ceramic composite filament of 1.7 mm in diameter based on PLA and biphasic calcium phosphates (BCPs) was obtained by hot-melt extrusion in a single screw extruder. The particles of BCP were obtained by solution-combustion synthesis, and the PLA used was commercial grade. The BCPs ceramics were characterized by X-ray diffraction (XRD), scanning electron microscopic (SEM), transmission electron microscopy (TEM), and Brunauer, Emmett, and Teller (BET). It was possible to confirm that the main inorganic phases were hydroxyapatite (HAP) and tricalcium phosphate (TCP) with grain sizes below 100 nm and with high porosity. The Filaments obtained are a bit fragile but were able to be used in fused deposition modelling (FDM) using low-cost commercial printers. The filaments were characterized by SEM and energy dispersive X-ray (EDX). The in-vitro tests of filaments showed deposition of apatite phases on their surface, non-cytotoxic behavior, adequate cell proliferation and cell adhesion.


Assuntos
Fosfatos de Cálcio , Hidroxiapatitas , Cerâmica , Durapatita , Teste de Materiais , Poliésteres , Porosidade , Engenharia Tecidual , Alicerces Teciduais
12.
Data Brief ; 29: 105295, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32154341

RESUMO

In additive manufacturing (AM), thermoplastic components made by fused deposition modeling (FDM) offer low strength and stiffness, as required for fully functional and load-bearing parts. Composite materials are a practical solution to improve mechanical properties [1,2]. A new technology to reinforce thermoplastics with continuous fibers has been developed recently by Markforged [3]. It introduces continuous fiber to reinforce a thermoplastic matrix, thus, taking static mechanical performance close to Aluminum alloys [4]. These printers for continuous fiber reinforced thermoplastic composites (CFRTPC) have taken this technology to a whole new level in terms of mechanical properties and efficient production. Mechanical properties under monotonic load were studied for different kinds of printing configurations. Tensile monotonic tests under controlled displacement were performed until rupture. Raw data showing tensile monotonic behavior provides the researchers with the ability to perform data fitting, to validate more advanced constitutive models, or to perform a further interpretation of the data, among others. Data is presented here as plain text files without any analysis. A preliminary data analysis has been published already in [5]. The text files contain information about time, displacement, and force. The data is useful for design engineers and researchers involved with AM.

13.
Brain Topogr ; 32(2): 229-239, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30341590

RESUMO

Accurate source localization of electroencephalographic (EEG) signals requires detailed information about the geometry and physical properties of head tissues. Indeed, these strongly influence the propagation of neural activity from the brain to the sensors. Finite difference methods (FDMs) are head modelling approaches relying on volumetric data information, which can be directly obtained using magnetic resonance (MR) imaging. The specific goal of this study is to develop a computationally efficient FDM solution that can flexibly integrate voxel-wise conductivity and anisotropy information. Given the high computational complexity of FDMs, we pay particular attention to attain a very low numerical error, as evaluated using exact analytical solutions for spherical volume conductor models. We then demonstrate the computational efficiency of our FDM numerical solver, by comparing it with alternative solutions. Finally, we apply the developed head modelling tool to high-resolution MR images from a real experimental subject, to demonstrate the potential added value of incorporating detailed voxel-wise conductivity and anisotropy information. Our results clearly show that the developed FDM can contribute to a more precise head modelling, and therefore to a more reliable use of EEG as a brain imaging tool.


Assuntos
Eletroencefalografia/métodos , Neuroimagem/métodos , Algoritmos , Anisotropia , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Mapeamento Encefálico , Interpretação Estatística de Dados , Eletroencefalografia/estatística & dados numéricos , Cabeça , Humanos , Imageamento por Ressonância Magnética , Modelos Anatômicos , Reprodutibilidade dos Testes
14.
Materials (Basel) ; 11(12)2018 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-30551631

RESUMO

In this work, we assess the effects of sterilization in materials manufactured using additive manufacturing by employing a sterilization technique used in the food industry. To estimate the feasibility of the hydrostatic high-pressure (HHP) sterilization of biomedical devices, we have evaluated the mechanical properties of specimens produced by commercial 3D printers. Evaluations of the potential advantages and drawbacks of Fused Deposition Modeling (FDM), Digital Light Processing (DLP) technology, and Stereolithography (SLA) were considered for this study due to their widespread availability. Changes in mechanical properties due to the proposed sterilization technique were compared to values derived from the standardized autoclaving methodology. Enhancement of the mechanical properties of samples treated with Hydrostatic high-pressure processing enhanced mechanical properties, with a 30.30% increase in the tensile modulus and a 26.36% increase in the ultimate tensile strength. While traditional autoclaving was shown to systematically reduce the mechanical properties of the materials employed and damages and deformation on the surfaces were observed, HHP offered an alternative for sterilization without employing heat. These results suggest that while forgoing high-temperature for sanitization, HHP processing can be employed to take advantage of the flexibility of additive manufacturing technologies for manufacturing implants, instruments, and other devices.

15.
Ther Deliv ; 8(11): 957-966, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29061104

RESUMO

The production process of 3D-printed drugs offers unique advantages such as the possibility of individualizing the drug therapy and easily associating different drugs and release technologies in the same pharmaceutical unit. Fused deposition modeling, a 3D printing technique, seems especially interesting for pharmaceutical applications, due to its low cost, precise and reproducible control of the printed structures, and versatility for industrial and laboratory scale. This technique combined with another technology already adapted for the pharmaceutical industry, the hot melt extrusion, is able to incorporate various mechanisms of modified drug release. This special report aims to bring together data of the experimental progress achieved using the fused deposition modeling 3D printing combined with hot melt extrusion technique and its potential in drug delivery. [Formula: see text].


Assuntos
Portadores de Fármacos/química , Medicina de Precisão , Impressão Tridimensional , Temperatura Alta , Nanoestruturas/química , Polímeros/química , Tecnologia Farmacêutica
16.
Electron. j. biotechnol ; Electron. j. biotechnol;29: 22-31, sept. 2017. ilus, tab, graf
Artigo em Inglês | LILACS | ID: biblio-1017065

RESUMO

Background: Reconstruction of customized cranial implants with a mesh structure using computer-assisted design and additive manufacturing improves the implant design, surgical planning, defect evaluation, implant-tissue interaction and surgeon's accuracy. The objective of this study is to design, develop and fabricate cranial implant with mechanical properties closer to that of bone and drastically decreases the implant failure and to improve the esthetic outcome in cranial surgery with precision fitting for a better quality of life. A customized cranial mesh implant is designed digitally, based on the Digital Imaging and Communication in Medicine files and fabricated using state of the Art-Electron Beam Melting an Additive Manufacturing technology. The EBM produced titanium implant was evaluated based on their mechanical strength and structural characterization. Results: The result shows, the produced mesh implants have a high permeability of bone ingrowth with its reduced weight and modulus of elasticity closer to that the natural bone thus reducing the stress shielding effect. Scanning electron microscope and micro-computed tomography (CT) scanning confirms, that the produced cranial implant has a highly regular pattern of the porous structure with interconnected channels without any internal defect and voids. Conclusions: The study reveals that the use of mesh implants in cranial reconstruction satisfies the need of lighter implants with an adequate mechanical strength, thus restoring better functionality and esthetic outcomes for the patients.


Assuntos
Humanos , Desenho de Prótese/métodos , Crânio , Telas Cirúrgicas , Titânio/química , Desenho Assistido por Computador , Procedimentos de Cirurgia Plástica/instrumentação , Fenômenos Mecânicos , Próteses e Implantes , Porosidade , Imageamento Tridimensional , Elasticidade , Elétrons
17.
J Magn Reson ; 243: 74-80, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24747788

RESUMO

Krylov Basis Diagonalization Method (KBDM) is a numerical procedure used to fit time domain signals as a sum of exponentially damped sinusoids. In this work KBDM is used as an alternative spectral analysis tool, complimentary to Fourier transform. We report results obtained from (13)C Nuclear Magnetic Resonance (NMR) by Steady State Free Precession (SSFP) measurements in brucine, C23H26N2O4. Results lead to the conclusion that the KBDM can be successfully applied, mainly because it is not influenced by truncation or phase anomalies, as observed in the Fourier transform spectra.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA