Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 39(6Part13): 3754, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28517361

RESUMO

PURPOSE: Since the 2001 IOM Report Crossing the Quality Chasm: A New Health System for the 21st Century, the need to provide quality metrics in health care has increased. Quality metrics have yet to be defined for the field of radiation oncology. This study represents one institutes initial efforts defining and measuring quality metrics using our electronic medical record and verify system(EMR) as a primary data collection tool. This effort began by selecting meaningful quality metrics rooted in the IOM definition of quality (safe, timely, efficient, effective, equitable and patient-centered care) that were also measurable targets based on current data input and workflow. METHODS: Elekta MOSAIQ 2.30.04D1 was used to generate reports on the number of Special Physics Consults(SPC) charged as a surrogate for treatment complexity, daily patient time in department(DTP) as a measure of efficiency and timeliness, and time from CT-simulation to first LINAC appointment(STL). The number of IMRT QAs delivered in the department was also analyzed to assess complexity. RESULTS: Although initial MOSAIQ reports were easily generated, the data needed to be assessed and adjusted for outliers. Patients with delays outside of radiation oncology such as chemotherapy or surgery were excluded from STL data. We found an average STL of six days for all CT-simulated patients and an average DTP of 52 minutes total time, with 23 minutes in the LINAC vault. Annually, 7.3% of all patient require additional physics support indicated by SPC. CONCLUSIONS: Utilizing our EMR, an entire year's worth of useful data characterizing our clinical experience was analyzed in less than one day. Having baseline quality metrics is necessary to improve patient care. Future plans include dissecting this data into more specific categories such as IMRT DTP, workflow timing following CT-simulation, beam-on hours, chart review outcomes, and dosimetric quality indicators.

2.
Med Phys ; 39(6Part28): 3968, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28519643

RESUMO

PURPOSE: To examine and facilitate the feasibility of the ArcCheck cylindrical diode array system as a patient specific QA device for CyberKnife radiosurgery delivery. METHODS: There is an obvious necessity for CyberKnife robotic radiosurgery patient QA procedures for hypofractionated treatment of larger planned treatment volumes (PTV), e.g. prostate. This need will increase when the future CyberKnife MLC is introduced. The small unflattened CyberKnife fields, along with the variation of beam-to-detector spatial angles, pose a significant detection challenge for dosimetric systems. The feasibility of the ArcCheck (Sun Nuclear Inc.) cylindrical diode array system for patient-specific QA on the CyberKnife is demonstrated using a beam-to-diode specific angular correction that was developed and has been applied. For localization and tracking, four gold seed fiducial markers were embedded in the system's central plug. We used a Monte Carlo 1% uncertainty for the dose calculation. RESULTS: By disabling the Linac based corrections and applying the custom CyberKnife correction that we developed, the passing rate increased from 39.6% to 99.8% using a 3%3mm gamma criteria for a given lung case. An additional lung case passed 98.5%. In both cases, a 10% dose threshold was used. In addition, brain, trigeminal nerve and lung cases with synchrony tracking are being investigated. CONCLUSIONS: We demonstrated the ArcCheck feasibility for CyberKnife patient specific QA performance. The custom CK angular correction that we developed and applied showed a high passing rate for the lung cases. A verification of the polar angle response should be conducted, in addition to the azimuthal angle that was verified for Linacs. Any data that is being retrieved is additional data to the current chamber point measurement procedures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA