1.
Injury ; 55(7): 111587, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38761709

RESUMO

AIM: to assess the small-scale 3D printing feasibility and cost estimation of a device for controlled dynamization. MATERIALS AND METHOD: The two-part device previously developed by our research group was printed with a carbon fiber-reinforced nylon filament (Gen3 CarbonX™ PA6+CF, 3DXTECH Additive Manufacturing) by a professional 3D printer (FUNMAT HT, Intamsys). Electricity, material, and labor costs for production in a Brazilian city in the Santa Catarina state were calculated. RESULTS: The devices for controlled dynamization were successfully printed in accordance with the planned design and dimensions. Six out of 38 printed devices presented defects in the bolt hole and were discarded. The average printing time per device was 1.9 h. The average electricity, material, and labor costs per printed device were respectively US$0.71, US$13.55, and US$3.04. The total production cost per device reaches approximately US$20 by adding the average cost of defective devices (15 %). CONCLUSION: 3D printing of the controlled dynamization device is feasible and its cost seems affordable to most healthcare services, which could optimize the consolidation of diaphyseal fractures and reduce treatment time for patients.


Assuntos
Estudos de Viabilidade , Impressão Tridimensional , Impressão Tridimensional/economia , Humanos , Desenho de Equipamento , Fixadores Externos/economia , Fixação de Fratura/instrumentação , Fixação de Fratura/métodos , Fixação de Fratura/economia , Brasil , Fraturas Ósseas/cirurgia
2.
Rev Bras Ortop (Sao Paulo) ; 59(2): e206-e212, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38606135

RESUMO

Objective To compare the functional outcomes of two circular external fixation techniques to treat complex fractures of the proximal end of the tibia. Materials and Methods The present is a retrospective cohort study with 51 patients who underwent surgical treatment for complex fractures of the tibial plateau with a circular external fixator. There were two groups of patients: 12 subjects underwent treatment with the classic assembly technique, and 39 subjects underwent treatment with the simplified technique. The variables analyzed included age, sex, injury mechanism, trauma energy, associated injuries, fixator type, time of fixator use, and clinical-radiographic outcomes. The classic technique mainly uses transfixing Kirschner wires, while the simplified one replaces the Kirschner wires with Schanz pins in the distal block of the circular external fixator. Result There were no statistically significant differences ( p > 0.05) between the two groups concerning the clinical-radiographic outcomes, including fracture consolidation, quality of joint fracture reduction, range of motion, lower limbs residual discrepancy, and postoperative pain. Conclusion We suggest that the simplified technique, using Schanz pins instead of Kirschner wires, can be a viable and effective alternative to treat complex fractures of the proximal end of the tibia with a circular external fixator. This simplified approach can offer benefits, such as a lower infection rate and greater patient comfort, without compromising clinical and radiographic outcomes, thus justifying its use.

3.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1533693

RESUMO

Introducción: Las fracturas supracondíleas del húmero en el niño son por lo general de tratamiento quirúrgico, mediante reducción cerrada o abierta asociada a la colocación de alambres. Por su parte, la fijación externa es una opción aceptada en ciertas circunstancias. Objetivo: Actualizar sobre el uso de la fijación externa en pacientes con fractura supracondílea del húmero en el niño. Métodos: Se realizó una búsqueda y análisis de la información en un periodo de 61 días (primero de junio al 31 de julio de 2023) y se emplearon las siguientes palabras: pediatric supracondylar humeral fractures AND external fixation, external fixation AND elbow, complex fractures AND pediatric supracondylar. A partir de la información obtenida se realizó una revisión bibliográfica de un total de 177 artículos publicados en las bases de datos PubMed, Hinari, SciELO y Medline mediante el gestor de búsqueda y administrador de referencias EndNote. De ellos, se utilizaron 34 citas seleccionadas para realizar la revisión, 32 de los últimos cinco años. Resultados: Se hizo referencia a las indicaciones y contraindicaciones, además de las ventajas de la fijación externa. Se mencionaron las principales diferencias entre la fijación con alambres de Kirschner y la fijación externa. Se expuso la técnica en cinco pasos. Se plasmaron los cuidados posoperatorios, complicaciones y comentarios sobre los resultados. Conclusiones: La fijación externa constituye una modalidad de tratamiento efectiva para pacientes pediátricos con patrones de fractura complejos. Es una técnica factible de realizar y reproducir. Los resultados son iguales o superiores al ser comparados con las otras modalidades quirúrgicas.


Introduction: Supracondylar humerus fractures in children are generally treated surgically, through closed or open reduction associated with placement of the wires. For its part, external fixation is an accepted option in certain circumstances. Objective: To update on the use of external fixation in patients with supracondylar fracture of the humerus in children. Methods: The search and analysis of the information was carried out in a period of 61 days (June 1st to July 31st, 2023) and the following words were used: pediatric supracondylar humeral fractures AND external fixation, external fixation AND elbow, complex fractures AND pediatric supracondylar. Based on the information obtained, a bibliographic review of a total of 177 articles published in the PubMed, Hinari, SciELO and Medline databases was carried out using the EndNote search engine and reference administrator. Of these, 34 selected citations were used to carry out the review, 32 of the last five years. Results: References are made to the indications and contraindications, in addition to the advantages of external fixation. The main differences between Kirschner wire fixation and external fixation are mentioned. The technique is exposed in five steps. Postoperative care, complications and comments on the results are reflected. Conclusions: External fixation is an effective treatment modality for pediatric patients with complex fracture patterns. It is a feasible technique to perform and reproduce. The results are equal or superior when compared with other surgical modalities.

4.
Rev. Bras. Ortop. (Online) ; 59(2): 206-212, 2024. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1565376

RESUMO

Abstract Objective To compare the functional outcomes of two circular external fixation techniques to treat complex fractures of the proximal end of the tibia. Materials and Methods The present is a retrospective cohort study with 51 patients who underwent surgical treatment for complex fractures of the tibial plateau with a circular external fixator. There were two groups of patients: 12 subjects underwent treatment with the classic assembly technique, and 39 subjects underwent treatment with the simplified technique. The variables analyzed included age, sex, injury mechanism, trauma energy, associated injuries, fixator type, time of fixator use, and clinical-radiographic outcomes. The classic technique mainly uses transfixing Kirschner wires, while the simplified one replaces the Kirschner wires with Schanz pins in the distal block of the circular external fixator. Result There were no statistically significant differences (p> 0.05) between the two groups concerning the clinical-radiographic outcomes, including fracture consolidation, quality of joint fracture reduction, range of motion, lower limbs residual discrepancy, and postoperative pain. Conclusion We suggest that the simplified technique, using Schanz pins instead of Kirschner wires, can be a viable and effective alternative to treat complex fractures of the proximal end of the tibia with a circular external fixator. This simplified approach can offer benefits, such as a lower infection rate and greater patient comfort, without compromising clinical and radiographic outcomes, thus justifying its use.


Resumo Objetivo Comparar os resultados funcionais entre duas técnicas de fixação externa circular utilizadas no tratamento de fraturas complexas da extremidade proximal da tíbia. Materiais e Métodos Trata-se de um estudo de coorte retrospectivo, com 51 pacientes submetidos ao tratamento cirúrgico de fraturas complexas do planalto tibial com fixador externo circular. Os pacientes foram divididos em dois grupos: 12 pacientes tratados com a técnica clássica e 39 pacientes tratados com a técnica simplificada. As variáveis analisadas incluíram idade, sexo, mecanismo da lesão, energia do trauma, lesões associadas, tipo de fixador, tempo de uso do fixador e resultados clínico-radiográficos. A técnica clássica lança mão principalmente de fios de Kirschner transfixantes, e a simplificada substitui os fios de Kirschner por pinos de Schanz no bloco distal do fixador externo circular. Resultados A partir da comparação das montagens, não encontramos diferenças estatisticamente significativas (p> 00,5) entre os dois grupos em relação aos resultados clínico-radiográficos, incluindo a consolidação da fratura, a qualidade da redução da fratura articular, a amplitude de movimento, a discrepância residual na medida dos membros inferiores e a dor do paciente no pós-operatório. Conclusão Sugerimos que a técnica simplificada, utilizando pinos de Schanz no lugar dos fios de Kirschner, pode ser uma alternativa viável e eficaz no tratamento de fraturas complexas da extremidade proximal da tíbia com fixador externo circular. Essa abordagem simplificada pode oferecer benefícios, como menor taxa de infecção e maior conforto para o paciente, sem comprometer os resultados clínicos e radiográficos, o que justifica, o seu uso.


Assuntos
Humanos , Fios Ortopédicos , Fixadores Externos , Técnica de Ilizarov , Fraturas do Planalto Tibial/terapia
5.
Rev. Bras. Ortop. (Online) ; 58(2): 351-355, Mar.-Apr. 2023. graf
Artigo em Inglês | LILACS | ID: biblio-1449808

RESUMO

Abstract Chronic distal radioulnar joint (DRUJ) dislocation has been treated historically with complex osteotomies and reconstructive procedures, often resulting in intractable stiffness and loss of function. It is desirable to use a technique of fixation that will not only restore the wrist biomechanics but also be cosmetically appealing to the individual. We present a novel technique of reduction and fixation of a chronically dislocated DRUJ in a 26-year-old male using a minimally invasive approach, with successful restoration of DRUJ function and no postoperative complications.


Resumo Luxação crônica da articulação radioulnar distal (ARUD) foi tratada historicamente com osteotomias complexas e procedimentos reconstrutivos, geralmente resultando em rigidez intratável e perda de função. É desejável usar uma técnica de fixação que não apenas restaure a biomecânica do punho, mas também seja esteticamente atraente para o indivíduo. Apresentamos uma nova técnica de redução e fixação de uma ARUD deslocada cronicamente em um homem de 26 anos, usando uma abordagem minimamente invasiva, com restauração bem-sucedida da função da ARUD e sem complicações pós-operatórias.


Assuntos
Humanos , Masculino , Adulto , Ortopedia/tendências , Traumatismos do Punho/cirurgia , Traumatismos do Punho/diagnóstico , Traumatismos do Punho/psicologia , Fixadores Externos
6.
Rev. venez. cir. ortop. traumatol ; 54(2): 53-61, dic. 2022. ilus
Artigo em Espanhol | LILACS, LIVECS | ID: biblio-1516086

RESUMO

La Impresión 3D es una tecnología emergente utilizada cada vez más en medicina. En los países en vías de desarrollo, donde las fracturas por motocicletas y automóviles se encuentran en aumento, la disponibilidad de fijadores externos para el manejo de fracturas abiertas es un problema frecuente. La impresión 3D puede ser una alternativa económica e igualmente confiable a los dispositivos tradicionales elaborados con acero o titanio. El objetivo de este trabajo es mostrar la experiencia con el uso de Impresión 3D y su aplicación en el manejo clínico de fracturas abiertas diafisiarias de tibia. Se realizó un estudio pre-experimental y prospectivo. Se incluyeron 14 pacientes con fracturas de tibia AO/ASIF 42A, 42B y 42C tratados con un fijador externo con rótulas elaboradas con Impresión 3D como medida de Control de Daños en Ortopedia desde su ingreso hasta su resolución definitiva. Todos los pacientes fueron de sexo masculino, con un promedio de edad 23,16 años con 50% entre 20-23 años. Las fracturas fueron 42,85% tipo 42A, 37,71% 42B y 21,42% 42C. El 78,57% de las fracturas fueron ocasionadas por motocicletas: 57,14% grado II según Gustilo y Anderson, un 28,57% grado III y 14,28% grado I. El 37,71% eran politraumatizados. Ninguno de los pacientes presentó complicaciones como pérdida de la reducción, aflojamiento de las rótulas, ruptura o fatiga de las rótulas ni fatiga de la barra. La impresión 3D demostró ser una herramienta y alternativa útil en el manejo agudo de fracturas abiertas diafisiarias de tibia(AU)


3D Printing is an emerging technology used more and more in medicine. In developing countries, where motorcycle and automobile fractures are on the rise, the availability of external fixators for the management of open fractures is a frequent problem. 3D printing can be a cheap and equally reliable alternative to traditional devices made of steel or titanium. The objective of this work is to show the experience with the use of 3D Printing and its application in the clinical management of open diaphyseal fractures of the tibia. A pre-experimental and prospective study was made. 14 patients with AO/ASIF tibia fractures 42A, 42B and 42C treated with an external fixator with 3D-printed ball-caps as a Damage Control measure in Orthopedics from admission to final resolution were included. All patients were male, with an average age of 23,16 years, 50% between 20-23 years. The fractures were 42,85% type 42A, 37,71% 42B and 21,42% 42C. 78,57% of the fractures were caused by motorcycles: 57,14% grade II according to Gustilo and Anderson, 28,57% grade III and 14.28% grade I. 37,71% were polytraumatized. None of the patients had complications such as loss of reduction, loosening of the patellas, rupture or fatigue of the patellas, or rod fatigue. 3D printing proved to be a useful tool and alternative in the acute management of open diaphyseal fractures of the tibia(AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Fraturas Expostas , Acidentes de Trânsito , Prontuários Médicos , Coleta de Dados
7.
Rev. Bras. Ortop. (Online) ; 57(6): 899-910, Nov.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1423637

RESUMO

Abstract Objective Over the last decades, volar locking plates (VLPs) have been the mainstay treatment for distal radius fractures (DRFs). With the growing body of evidence, we systematically reviewed studies on recent VLP modifications. Methods A systematic search was performed in the PubMed/MEDLINE database for studies published in English in the past five years. The inclusion criteria were randomized controlled trials (RCTs) on the operative treatment of DRFs. We excluded ongoing trials and studies not directly addressing DRF. The primary outcomes assessed were subjective (such as the scores on the Disabilities of the Arm, Shoulder and Hand [DASH] questionnaire, the Patient-rated Wrist Evaluation [PRWE], the European Quality of Life-5 Dimensions [EQ-5D], the 36-item Short Form Health Survey [SF-36], and the Visual Analog Scale [VAS]) and objective clinical outcomes (the complication rate). Results We identified 29 articles published from 2016 to 2020 with high quality of evidence, except for one, which had evidence of moderate quality. In total, 3,079 DRFs were analyzed in the present study. All studies except one had a greater proportion of female participants, and only in 1 study the mean age of the sample was < 40 years old. There were no significant differences between the VLP and external fixation (EF) in terms of the scores on the DASH (p= 0.18) and PRWE (p= 0.77). The VLP alone without pronator quadratus (PQ) repair yielded significantly better outcomes. Conclusion In unstable fractures, the VLP and EF yielded comparable long-term results. There is no clear benefit of adding PQ repair to current the VLP surgical technique. Level of EvidenceLevel I


Resumo Objetivo Nas últimas décadas, a placa volar bloqueada (PVB) tem sido o tratamento principal para fraturas do rádio distal (FRDs). Com o crescente conjunto de evidências, revisamos sistematicamente estudos sobre modificações recentes na PVB. Métodos Uma pesquisa sistemática foi realizada utilizando o banco de dados PubMed/MEDLINE por estudos publicados em inglês nos últimos cinco anos. Os critérios de inclusão foram ensaios clínicos controlados e randomizados (ECCRs) sobre o tratamento cirúrgico de FRDs. Excluímos ensaios e estudos em andamento que não abordavam diretamente a FRD. Os desfechos primários avaliados foram desfechos clínicos subjetivos (como as pontuações no questionário de Deficiências do Braço, Ombro e Mão [Disabilities of the Arm, Shoulder and Hand, DASH, em inglês], na Avaliação do Punho Classificada pelo Paciente [Patient-rated Wrist Evaluation, PRWE, em inglês], no questionário Qualidade de Vida Europeia - 5 Dimensões [European Quality of Life-5 Dimensions, EQ-5D, em inglês], na Pesquisa de Saúde por Formulário Curto de 36 Itens [36-item Short Form Health Survey, SF-36, em inglês], e na Escala Visual Analógica [EVA]) e objetivos (taxa de complicações). Resultados Identificamos 29 artigos publicados entre 2016 e 2020 com alta qualidade de evidência, exceto por um, de qualidade moderada. Ao todo, foram analisadas 3.079 FRDs neste estudo, Todos os estudos analisados, exceto por um, tinham maior proporção de participantes do gênero feminino, e somente em 1 estudo a idade média da amostra foi < 40 anos. Não houve diferença significativa entre a PVB e fixação externa (FE) em termos das pontuações no DASH (p= 0,18) e na PRWE (p= 0,77). Os resultados da PVB isolada, sem qualquer reparo do pronador quadrado (PQ), foram significativamente melhores. Conclusão Em fraturas instáveis, a PVB e a FE produziram resultados comparáveis no longo prazo. Não há um benefício claro em se adicionar reparo do PQ à técnica cirúrgica atual da PVB. Nível de EvidênciaNível I


Assuntos
Fraturas do Rádio/cirurgia , Traumatismos do Punho/cirurgia , Placas Ósseas , Fixadores Externos
8.
Acta Ortop Bras ; 30(4): e250322, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36092181

RESUMO

Introduction: Indications for provisional external fixation prior to the definitive treatment of fractures are associated with the control of local and systemic damage and the impossibility of definitive osteosynthesis in the emergency. Objective: To identify complications associated with external fixation prior to definitive internal osteosynthesis. Methods: This is a comparative, prospective study (Level II). Inclusion criteria: patients treated as emergencies (November 2019 and March 2020) who underwent provisional external correction followed by definitive osteosynthesis. We look for signs of inadequacies in external correction and correlation with infections (erythema, hyperemia, fistulae in the path of the pins or surgical scars), systemic symptoms of infection, and radiographic parameters for treatment up to eight weeks after surgery. Results: The average time for conversion to definitive osteosynthesis was 15.9 days and 47 lower limbs and three upper limbs were fixed. Of the participants who had deep infections, three (6%) showed signs during initial treatment (external fixator) and nine (18%), after definitive internal osteosynthesis. We found no correlation between provisional external correction and complications in the definitive treatment with osteosynthesis. Conclusion: The use of temporary external fixation before definitive internal osteosynthesis in fractures of the appendicular skeleton failed to increase complication rates even if the path of the implants in both procedures overlapped. Level of Evidence II, Comparative Prospective Study.


Introdução: As indicações para a fixação externa provisória que antecedem o tratamento definitivo das fraturas está associado ao controle do dano local e sistêmico e à impossibilidade de osteossíntese definitiva na urgência. Objetivo: Identificar complicações associadas à fixação externa precedente à osteossíntese interna definitiva. Métodos: Estudo prospectivo comparativo realizado com pacientes atendidos em situação de urgência entre novembro de 2019 e março de 2020, que sofreram a fixação externa provisória seguida de osteossíntese definitiva. Buscamos indícios de inadequações na fixação externa e correlação com: infecção (eritema, hiperemia, fístula do trajeto dos pinos ou da cicatriz cirúrgica), sintomas sistêmicos de infecção e parâmetros radiográficos da evolução do tratamento até oito semanas do pós-operatório. Resultados: O tempo médio para conversão em osteossíntese definitiva foi de 15,9 dias, e foram fixados 47 membros inferiores e 3 membros superiores. Dos participantes que apresentaram quadros de infecções profundas, três (6%) apresentaram os sinais durante o tratamento inicial (fixador externo) e nove (18%) após a osteossíntese interna definitiva. Não foi encontrada correlação entre a fixação externa provisória e complicações no tratamento definitivo com osteossíntese. Conclusão: O emprego da fixação externa temporária antes da osteossíntese interna definitiva em fraturas do esqueleto apendicular não provocou aumento nas taxas de complicações, mesmo quando houve sobreposição no trajeto dos implantes usados nos dois procedimentos. Nível de Evidência II, Estudo Prospectivo Comparativo.

9.
Rev Bras Ortop (Sao Paulo) ; 57(2): 214-217, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35652033

RESUMO

Objective To evaluate the quality of life of patients using an Ilizarov type external fixator for the treatment of complicated fractures and their sequelae. Method This is an observational and cross-sectional study, in which the 36-item short form survey (SF-36) questionnaire (translated into Portuguese) was applied during outpatient consultations in 2 periods, in the months of July 2018 and January 2019. The patients who participated in the study underwent their surgical procedures between January and June 2018. Results We evaluated 36 patients using an external Ilizarov fixator. We observed a predominance of male patients, with a mean age of 37.9 years. Fractures of leg bones and their complications represented half of the sample. Improvement in functional capacity and emotional aspects of the patients was observed throughout the treatment. Conclusion The use of the circular external fixator is an important and effective method for the surgical treatment of complex fractures and their sequelae. This study allowed us to conclude that, after treatment, patients achieved functional return to daily activities with adequate quality of life.

10.
Rev. Bras. Ortop. (Online) ; 57(2): 214-217, Mar.-Apr. 2022. tab
Artigo em Inglês | LILACS | ID: biblio-1387989

RESUMO

Abstract Objective To evaluate the quality of life of patients using an Ilizarov type external fixator for the treatment of complicated fractures and their sequelae. Method This is an observational and cross-sectional study, in which the 36-item short form survey (SF-36) questionnaire (translated into Portuguese) was applied during outpatient consultations in 2 periods, in the months of July 2018 and January 2019. The patients who participated in the study underwent their surgical procedures between January and June 2018. Results We evaluated 36 patients using an external Ilizarov fixator. We observed a predominance of male patients, with a mean age of 37.9 years. Fractures of leg bones and their complications represented half of the sample. Improvement in functional capacity and emotional aspects of the patients was observed throughout the treatment. Conclusion The use of the circular external fixator is an important and effective method for the surgical treatment of complex fractures and their sequelae. This study allowed us to conclude that, after treatment, patients achieved functional return to daily activities with adequate quality of life.


Resumo Objetivo Avaliar a qualidade de vida dos pacientes em uso do fixador externo do tipo Ilizarov para tratamento de fraturas complexas e de suas sequelas Método Trata-se de um estudo observacional e transversal, em que foi aplicado o questionário 36-item short form survey (SF-36) (traduzido para a língua portuguesa) durante as consultas ambulatoriais em 2 períodos, nos meses de julho de 2018 e janeiro de 2019. Os pacientes que participaram do estudo realizaram seus procedimentos cirúrgicos no período de janeiro a junho de 2018. Resultados Foram avaliados 36 pacientes em uso de fixador externo do tipo Ilizarov. Foi observado predomínio do sexo masculino e idade média de 37,9 anos. As fraturas de ossos da perna e suas complicações representaram metade da amostra. Foi observada melhora na capacidade funcional e nos aspectos emocionais dos pacientes ao longo do tratamento. Conclusão O uso do fixador externo circular constitui um método importante e eficaz para o tratamento cirúrgico de fraturas complexas e de suas sequelas. Este trabalho permitiu concluir que, após o tratamento, os pacientes alcançaram retorno funcional às atividades diárias com adequada qualidade de vida.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Qualidade de Vida , Atividades Cotidianas , Perfil de Impacto da Doença , Técnica de Ilizarov/reabilitação , Fraturas Ósseas/reabilitação , Inquéritos e Questionários
11.
Acta ortop. bras ; Acta ortop. bras;30(4): e250322, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1393789

RESUMO

ABSTRACT Introduction: Indications for provisional external fixation prior to the definitive treatment of fractures are associated with the control of local and systemic damage and the impossibility of definitive osteosynthesis in the emergency. Objective: To identify complications associated with external fixation prior to definitive internal osteosynthesis. Methods: This is a comparative, prospective study (Level II). Inclusion criteria: patients treated as emergencies (November 2019 and March 2020) who underwent provisional external correction followed by definitive osteosynthesis. We look for signs of inadequacies in external correction and correlation with infections (erythema, hyperemia, fistulae in the path of the pins or surgical scars), systemic symptoms of infection, and radiographic parameters for treatment up to eight weeks after surgery. Results: The average time for conversion to definitive osteosynthesis was 15.9 days and 47 lower limbs and three upper limbs were fixed. Of the participants who had deep infections, three (6%) showed signs during initial treatment (external fixator) and nine (18%), after definitive internal osteosynthesis. We found no correlation between provisional external correction and complications in the definitive treatment with osteosynthesis. Conclusion: The use of temporary external fixation before definitive internal osteosynthesis in fractures of the appendicular skeleton failed to increase complication rates even if the path of the implants in both procedures overlapped. Level of Evidence II, Comparative Prospective Study.


RESUMO Introdução: As indicações para a fixação externa provisória que antecedem o tratamento definitivo das fraturas está associado ao controle do dano local e sistêmico e à impossibilidade de osteossíntese definitiva na urgência. Objetivo: Identificar complicações associadas à fixação externa precedente à osteossíntese interna definitiva. Métodos: Estudo prospectivo comparativo realizado com pacientes atendidos em situação de urgência entre novembro de 2019 e março de 2020, que sofreram a fixação externa provisória seguida de osteossíntese definitiva. Buscamos indícios de inadequações na fixação externa e correlação com: infecção (eritema, hiperemia, fístula do trajeto dos pinos ou da cicatriz cirúrgica), sintomas sistêmicos de infecção e parâmetros radiográficos da evolução do tratamento até oito semanas do pós-operatório. Resultados: O tempo médio para conversão em osteossíntese definitiva foi de 15,9 dias, e foram fixados 47 membros inferiores e 3 membros superiores. Dos participantes que apresentaram quadros de infecções profundas, três (6%) apresentaram os sinais durante o tratamento inicial (fixador externo) e nove (18%) após a osteossíntese interna definitiva. Não foi encontrada correlação entre a fixação externa provisória e complicações no tratamento definitivo com osteossíntese. Conclusão: O emprego da fixação externa temporária antes da osteossíntese interna definitiva em fraturas do esqueleto apendicular não provocou aumento nas taxas de complicações, mesmo quando houve sobreposição no trajeto dos implantes usados nos dois procedimentos. Nível de Evidência II, Estudo Prospectivo Comparativo.

12.
Rev. méd. Urug ; 37(3): e37308, set. 2021. tab, graf
Artigo em Espanhol | LILACS, BNUY | ID: biblio-1341556

RESUMO

Resumen: Introducción: la luxación traumática de la rodilla constituye una lesión rara dentro de la patología ortopédica. En muchas ocasiones su diagnóstico pasa desapercibido dado que se dan en el contexto de pacientes politraumatizados, y la falla en el mismo puede derivar en un pronóstico potencialmente letal para el compromiso vital del miembro lesionado. Objetivo: realizar una revisión de la literatura disponible en los últimos veinte años acerca de cuáles son las indicaciones del uso del fijador externo (FFEE) en la luxación traumática aguda de rodilla en la urgencia. Materiales y métodos: se realizó una búsqueda sistematizada a través de los buscadores electrónicos Cochrane, Lilacs, Scielo, Pubmed, Science direct y el portal Timbó. La misma alcanzó un total de 6.495 artículos, y de acuerdo con los criterios de inclusión y exclusión se seleccionaron 14 trabajos para realizarla. Resultados: se destaca que la mayoría de los artículos encontrados son de nivel de evidencia IV. La utilización del uso de la fijación externa en la urgencia como parte de la estabilización temporal y el manejo inicial estaría indicado en los siguientes escenarios clínicos: pacientes politraumatizados, lesión vascular, luxación expuesta, inestabilidad de la articulación, luxación recidivante, luxofracturas, lesiones a nivel del aparato extensor, obesidad mórbida, intolerancia del uso de la férula u ortesis. Conclusión: la sistematización y protocolización a la hora de la toma de decisiones permite disminuir de forma mayoritaria las complicaciones vinculadas a la patología traumática; éstas deben estar dirigidas a la estabilización del paciente en primera instancia, y en segunda instancia a estabilizar la articulación de la rodilla. La fijación externa tiene indicaciones en escenarios clínicos puntuales; sin embargo algunas de estas indicaciones aún son objeto de debate.


Abstract: Introduction: traumatic dislocation of the knee constitutes an unusual lesion in orthopedic pathology, the diagnosis of which is often missed. This is because it occurs in the context of multiple trauma patients, and failure to diagnose it may result in a potentially fatal outcome for the life-threatening compromise of the injured limb. Objective: to perform a literature review of literature on indications for the use of the external fixator in the acute knee dislocation at the emergency room that has been available in the last twenty years. Method: we conducted a systematized search by means of electronic search engines Cochrane, Lilacs, Scielo, Pubmed, Science direct and the Timbó portal. The search included 6495 articles and according to the criteria of inclusion and exclusion 14 studies were selected. Results: the review highlights that most articles found are level of evidence IV. The use of the external fixator in the emergency room as part of the temporary stabilization and initial handling of the condition would be indicated in the following clinical scenarios: multiple trauma patients, vascular lesion, exposed dislocation, joint instability, recurrent dislocation, fracture dislocation, lesions of the extensor apparatus, morbid obesity, splint or orthosis intolerance. Conclusion: systematization and the observation of protocols when it comes to the making of decisions enables the decrease of most complications associated to trauma pathologies. Actions must be geared to stabilizing patients first and to stabilize the knee joint. The external fixator is indicated for specific clinical scenarios. However, some of these indications are still a matter of debate.


Resumo: Introdução: a luxação traumática do joelho é uma lesão rara na patologia ortopédica. Em muitas ocasiões, seu diagnóstico passa despercebido, por ocorrer no contexto de pacientes politraumatizados, e que sua falha pode levar a um prognóstico potencialmente letal para o envolvimento vital do membro lesado. Objetivo: realizar uma revisão da literatura disponível nos últimos vinte anos sobre as indicações do uso do fixador externo na luxação traumática aguda do joelho em pronto-socorro. Materiais e métodos: foi realizada uma busca sistemática nas bases LILACS, SciELO, PubMed, Science Direct, na Biblioteca Cochrane e no portal Timbó. Foram obtidas 6.495 referencias dos quais 14 artigos foram selecionados de acordo com os critérios de inclusão e exclusão. Resultados: a maioria dos artigos encontrados apresentam evidência de nível IV. O uso de fixação externa na emergência como parte da estabilização temporária e manejo inicial, seria indicado nos seguintes cenários clínicos: pacientes politraumatizados, lesão vascular, luxação exposta, instabilidade articular, luxação recorrente, luxação, lesões ao nível do aparelho extensor, obesidade mórbida, intolerância ao uso de tala ou órtese. Conclusão: a sistematização e protocolização no momento da tomada de decisão é o que possibilita reduzir, em sua maioria, as complicações relacionadas à patologia traumática. Estas devem ter como objetivo em primeiro lugar estabilizar o paciente e, em segundo lugar, estabilizar a articulação do joelho. A fixação externa tem indicações em contextos clínicos específicos; no entanto, algumas delas ainda geram controvérsia.


Assuntos
Fixadores Externos , Luxação do Joelho , Traumatismos do Joelho , Serviços Médicos de Emergência
13.
Arch. méd. Camaguey ; 25(2): e7003, mar.-abr. 2021. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1248833

RESUMO

RESUMEN Fundamento: las luxaciones puras del tobillo son lesiones muy infrecuentes, causadas por trauma de alta energía en especial los accidentes del tránsito y caídas de alturas. El tratamiento es por lo general quirúrgico. Objetivo: conocer una paciente con luxación traumática, pura y abierta de la articulación del tobillo. Presentación del caso: paciente de 50 años de edad, mestiza, femenina sin antecedentes mórbidos de salud, la cual sufrió caída de una altura aproximada de tres metros y es traída al cuerpo de guardia del Servicio de Ortopedia y Traumatología por presentar dolor e impotencia funcional total del tobillo derecho. Mediante la exploración física se detectó luxación abierta del tobillo derecho con franca exposición de las superficies articulares de la tibia distal y el astrágalo, además de tendones y partes blandas. Al tener en cuenta todos los elementos anteriores, se decidió llevar la paciente al quirófano, para tratamiento de tipo quirúrgico. De manera inmediata se realizó limpieza, irrigación pulsátil y desbridamiento de la herida en la articulación del tobillo, sutura de las partes blandas dañadas y se colocó fijación externa tipo Hoffman® en configuración de tipo triangular. Conclusiones: el tratamiento por general consiste en la reducción e inmovilización por seis semanas, sin embargo, en caso de afección severa de las partes blandas, donde se necesite la observación y cura de las heridas de forma sistemática, está justificado el uso de la fijación externa como lo es en el caso que se presentó.

14.
Rev Bras Ortop (Sao Paulo) ; 56(1): 36-41, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33627897

RESUMO

Objective To virtually prototype a device for external circular fixation of long bone fractures with controlled dynamization made of two different materials and predict their mechanical behavior by using the finite element analysis (FEA) method. Method A software was used for 3D modeling two metal parts closely attached by a sliding dovetail joint and a high-density silicone damper. Distinctive FEAs were simulated by considering two different materials (stainless steel or titanium), modes (locked or dynamized) and loading conditions (static/point or dynamic/0.5 sec) with uniform 150 kg axial load on top of the device. Results The finite elements (FEs) model presented 81,872 nodes and 45,922 elements. Considering stainless steel, the maximum stress peak (140.98 MPa) was reached with the device locked under static loading, while the greatest displacement (2.415 × 10 -3 mm) was observed with the device locked and under dynamic loading. Regarding titanium, the device presented the maximum stress peak (141.45 MPa) under static loading and with the device locked, while the greatest displacement (3.975 × 10 -3 mm) was found with the device locked and under dynamic loading. Conclusion The prototyped device played the role of stress support with acceptable deformation in both locked and dynamized modes and may be fabricated with both stainless steel and titanium.

15.
Rev Bras Ortop (Sao Paulo) ; 56(1): 61-68, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33627901

RESUMO

Objective To evaluate and compare the clinical and radiological outcomes of patients with comminuted distal radius fractures treated with an external fixator or a dorsal bridge plate. Methods In total, 45 patients were analyzed 1 year after surgery; 18 were treated with an external fixator, and 25 received a dorsal bridge plate. An analog pain scale and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire were applied, in addition to radiographic, strength and range of motion assessments. Statistical analyzes were performed using the chi-squared test and the Mann-Whitney non-parametric test. Results Fractures were more common in women over 60 years old who suffered falls from their own height. Both methods demonstrated similar functional and radiological results. Infections were more prevalent in patients receiving external fixators, but their residual grip strength was better. Reflex sympathetic neuropathy was more common in subjects treated with a dorsal bridge plate. Conclusion Our analysis showed no consensus on the superiority of one method over the other. Each method had advantages and disadvantages, but both led to good, similar outcomes. The treatment must be chosen according to the profile of the trauma, the patient's clinical conditions, the surgeon's experience, and the availability of materials.

16.
Rev. Bras. Ortop. (Online) ; 56(1): 61-68, Jan.-Feb. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1288645

RESUMO

Abstract Objective To evaluate and compare the clinical and radiological outcomes of patients with comminuted distal radius fractures treated with an external fixator or a dorsal bridge plate. Methods In total, 45 patients were analyzed 1 year after surgery; 18 were treated with an external fixator, and 25 received a dorsal bridge plate. An analog pain scale and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire were applied, in addition to radiographic, strength and range of motion assessments. Statistical analyzes were performed using the chi-squared test and the Mann-Whitney non-parametric test. Results Fractures were more common in women over 60 years old who suffered falls from their own height. Both methods demonstrated similar functional and radiological results. Infections were more prevalent in patients receiving external fixators, but their residual grip strength was better. Reflex sympathetic neuropathy was more common in subjects treated with a dorsal bridge plate. Conclusion Our analysis showed no consensus on the superiority of one method over the other. Each method had advantages and disadvantages, but both led to good, similar outcomes. The treatment must be chosen according to the profile of the trauma, the patient's clinical conditions, the surgeon's experience, and the availability of materials.


Resumo Objetivo Avaliar e comparar os resultados clínicos e radiológicos de pacientes com fraturas cominutivas distais do rádio tratados com fixador externo ou placa ponte dorsal. Métodos Foram analisados 45 pacientes, sendo 18 tratados com fixador externo, e 25, com placa ponte dorsal, após 1 ano de pós-operatório. Aplicou-se uma escala analógica de dor e o questionário Disabilities of the Arm, Shouder and Hand (DASH), além de análise radiográfica, da avaliação de força, e da amplitude de movimento. As análises estatísticas foram realizadas utilizando o teste qui-quadrado e o teste não paramétrico de Mann-Whitney. Resultados A fratura foi mais comum em mulheres acima de 60 anos por queda do mesmo nível. Ambos os métodos demonstraram resultados funcional e radiológico similares. A infecção foi mais prevalente com o uso do fixador externo, mas a força de preensão residual foi melhor. Neuropatia simpático-reflexa foi mais comum com o uso da placa ponte dorsal. Conclusão Não houve consenso da superioridade de um método em relação ao outro em nossa análise. Cada um dos métodos apresenta vantagens e desvantagens, mas ambos mostraram resultados bons e semelhantes. A escolha do tratamento deve ser atribuída ao perfil do trauma, às condições clínicas do paciente, à experiência do profissional, e à disponibilidade de materiais.


Assuntos
Humanos , Período Pós-Operatório , Placas Ósseas , Fixadores Externos
17.
Rev. Bras. Ortop. (Online) ; 56(1): 36-41, Jan.-Feb. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1288660

RESUMO

Abstract Objective To virtually prototype a device for external circular fixation of long bone fractures with controlled dynamization made of two different materials and predict their mechanical behavior by using the finite element analysis (FEA) method. Method A software was used for 3D modeling two metal parts closely attached by a sliding dovetail joint and a high-density silicone damper. Distinctive FEAs were simulated by considering two different materials (stainless steel or titanium), modes (locked or dynamized) and loading conditions (static/point or dynamic/0.5 sec) with uniform 150 kg axial load on top of the device. Results The finite elements (FEs) model presented 81,872 nodes and 45,922 elements. Considering stainless steel, the maximum stress peak (140.98 MPa) was reached with the device locked under static loading, while the greatest displacement (2.415 × 10−3 mm) was observed with the device locked and under dynamic loading. Regarding titanium, the device presented the maximum stress peak (141.45 MPa) under static loading and with the device locked, while the greatest displacement (3.975 × 10−3 mm) was found with the device locked and under dynamic loading. Conclusion The prototyped device played the role of stress support with acceptable deformation in both locked and dynamized modes and may be fabricated with both stainless steel and titanium.


Resumo Objetivo Construir um protótipo virtual de um dispositivo de fixação circular externa para fraturas em ossos longos com dinamização controlada a partir de dois materiais diferentes e prever seu comportamento mecânico por meio da análise de elementos finitos AEF). Método Modelos tridimensionais compostos de duas peças metálicas unidas por uma junta deslizante em rabo de andorinha e um amortecedor de silicone de alta densidade foram criados em um software. Análises de elementos finitos distintas foram simuladas considerando dois materiais (aço inoxidável ou titânio), modos (bloqueado ou dinamizado) e condições de carregamento (estático/pontual ou dinâmico/0,5 segundo) diferentes com carga axial uniforme de 150 kg na porção superior do dispositivo. Resultados O modelo de elementos finitos (EFs) apresentou 81.872 nós e 45.922 elementos. Com aço inoxidável, o pico de tensão máxima (140,98 MPa) foi alcançado com o dispositivo bloqueado e sob carga estática, enquanto o maior deslocamento (2.415 × 10−3 mm) foi obtido com o dispositivo bloqueado e sob carga dinâmica. Com titânio, o pico de tensão máxima (141,45 MPa) ocorreu com o dispositivo bloqueado e sob carga estática, enquanto o maior deslocamento (3.975 × 10−3 mm) foi observado com o dispositivo bloqueado e sob carga dinâmica. Conclusão O protótipo do dispositivo desempenhou o papel de suporte de tensão com deformação aceitável nos dois modos, bloqueado ou dinamizado, e pode ser fabricado com aço inoxidável ou titânio.


Assuntos
Humanos , Adulto , Escoliose/fisiopatologia , Escoliose/terapia , Análise de Elementos Finitos , Degeneração do Disco Intervertebral
18.
Medisur ; 18(6): 1225-1232, nov.-dic. 2020. graf
Artigo em Espanhol | LILACS | ID: biblio-1149425

RESUMO

RESUMEN La fractura luxación del tobillo se presenta con alguna frecuencia en la práctica médica. La asociación de una luxación en las fracturas de tobillo modifica su abordaje terapéutico puesto que la articulación no debe permanecer por más de seis horas en dicha situación y por ende se requerirá del tratamiento quirúrgico de urgencia. Son conocidas las complicaciones relacionadas con la no reducción de una luxación en el periodo de tiempo mencionado anteriormente, dentro de estas, la necrosis avascular del astrágalo representa la más temida debido a la incapacidad que genera. Por tales razones se decidió presentar un caso que muestra el tratamiento de una fractura -luxación del tobillo derecho, en una paciente de 30 años de edad, estabilizada mediante el empleo de un mini fijador RALCA, la cual fue seguida por un periodo de cinco años.


ABSTRACT Ankle fracture dislocation occurs with some frequency in medical practice. The association of a dislocation in ankle fractures modifies its therapeutic approach since the joint should not remain for more than six hours in this situation and therefore emergency surgical treatment will be required. Complications related to the non-reduction of a dislocation in the previously mentioned period of time are known; within these, avascular necrosis of the talus represents the most feared due to the disability it generates. For these reasons, it was decided to present a case that shows the treatment of a fracture -luxation of the right ankle, in a 30-year-old patient, stabilized by using a RALCA mini fixator, which was followed for a period of five years.


Assuntos
Humanos , Feminino , Adulto , Fraturas do Tornozelo/complicações , Fraturas do Tornozelo/terapia , Fraturas do Tornozelo/cirurgia
19.
Rev. salud bosque ; 10(2): 1-23, Septiembre 18, 2020.
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1284324

RESUMO

Introducción. La fijación externa es un método para tratar diferentes tipos de fracturas mediante el posicionamiento de agujas o clavos en sitios periféricos a los segmentos de la ruptura Objetivo. Identificar las complicaciones más frecuentes derivadas de la implantación de fijadores externos. Materiales y métodos. Se realizó una revisión de la literatura en las bases de datos ScienceDirect, SpringerLink, Proquest, PubMed, SciELO, ClinicalKey, Elsevier y Redalyc. Se incluyeron estudios publicados entre 2014 y 2018, y en idioma inglés y español. Resultados. Se encontraron 1.104 artículos y se excluyeron 1.058 por no cumplir los criterios de inclusión o por no contar con información de interés para el estudio, por lo que finalmente se incluyeron 46 publicaciones. Conclusiones. Las infecciones fueron las complicaciones más frecuentes asociadas al uso de la fijación externa y por tanto son un importante reto para los profesionales de la salud.


Introduction: External fixation is the method of treating different types of fractures using needles or pins that are positioned at peripheral sites of the fracture segments. Materials and methods: A descriptive documentary study was carried out, reviewing the literature, taking into account the review of 46 scientific articles, belonging to databases such as: Science Direct, SpringerLink, Proquest, PubMed, SciELO, ClinicalKey, Elsevier and Redalyc; studies were included between 2014 - 2018, in English and Spanish language. Results: We located 1104 articles, excluding 1058 because they did not meet the inclusion criteria or did not have information of interest to the study. Conclusions: The most frequent complications associated with the use of external fixation are those related to infection, generating an important challenge for health professionals.


Introdução. A fixação externa é um método de tratamento de diferentes tipos de fraturas, com posicionamento de agulhas ou pregos em locais periféricos aos segmentos de ruptura e precisa de cuidados especiais. Objetivo. Identificar as complicações mais frequentes derivadas do implante de fixadores externos. Materiais e métodos. Foi realizada uma revisão da literatura nas bases de dados (ScienceDirect, SpringerLink, Proquest, PubMed, SciELO, ClinicalKey, Elsevier e Redalyc) de estudos publicados entre 2014 e 2018 em língua inglesa e espanhola. Resultados. No total foram analizados 46 artigos dos 1.058 achados, 1.104 foram excluídos por não atenderem os critérios de inclusão ou por não possuirem informações de interesse do estudo. Conclusões. As infecções foram as complicações mais frequentes associadas ao uso de fixação externa, são o maior desafio para os profissionais de saúde.


Assuntos
Ortopedia , Procedimentos Cirúrgicos Operatórios , Disciplinas das Ciências Naturais
20.
Arch. méd. Camaguey ; 24(4): e6417, jul.-ago. 2020. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1131151

RESUMO

RESUMEN Fundamento: las fracturas de la meseta tibial son lesiones traumáticas frecuentes por lo general son provocadas por mecanismos de compresión vertical en varo o valgo, de allí la incidencia de fracturas abiertas con pérdida de piel no son frecuentes, ya que estas responden por lo general a mecanismos directos. Objetivo: presentar el caso de una paciente con fractura abierta de la meseta tibial tipo VI de Schatzker J. Presentación del caso: paciente de 61 años de edad, mestiza, femenina sin antecedentes mórbidos de salud, la cual sufre accidente del tránsito al proyectarse contra un camión y es traída al servicio de urgencias de Ortopedia y Traumatología por presentar dolor e inflamación a nivel de la rodilla y pierna izquierda, que le impide la marcha y los movimientos, además de presentar herida avulsiva de base distal que se comunicaba con el foco de fractura. El examen radiográfico simple de la rodilla izquierda en proyecciones anteroposterior y lateral mostró solución de continuidad del tejido óseo a nivel de la zona metafiso-epifisaria de la tibia proximal izquierda. El tratamiento definitivo de la paciente consistió en la colocación de tornillo canulado y fijación externa tipo Hoffman 1® mediante dos anclajes en el fémur y tibia. Conclusiones: las fracturas de la meseta tibial tipo VI de Schatzker J, son lesiones traumáticas de difícil tratamiento debido a su asociación a complicaciones como: comunicación con el exterior y pérdida de piel. La fijación externa es un método de osteosíntesis útil y de fácil aplicación, que permite el tratamiento de estas lesiones complicadas.


ABSTRACT Background: tibial plateau fractures are common traumatic lesions due to vertical compression in varus and valgus. That is why open fractures associated to skin loss are not so frequent, because they are caused by direct mechanisms. Objetive: to present the case of a patient with an open fracture of the tibial plateau type VI by Schatzker J. Case report: a 61 year old mixed race, woman without health morbid antecedents, who after having a traffic accident was taken to emergency room of Orthopedics and Traumatology complaining of pain, swelling and limitation of movement of the left knee and leg. Simple imaging examination in antero-posterior and lateral views showed a structural break in the continuity of bone at epiphysis and metaphysis in the left proximal tibia. Definite treatment consisted of an osteosynthesis with cannulated screw and fixation by an external device type Hoffmann 1 with two pins in femur and tibia respectively. Conclusions: tibial plateau fractures type VI according to Schatzker J classification system are difficult to treat because of associated lesions and complications as open fractures and skin loss. External fixation is a useful and easy method to fix complex fractures as tibial plateau fractures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA