Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Arch. cardiol. Méx ; Arch. cardiol. Méx;93(2): 172-182, Apr.-Jun. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1447248

RESUMO

Abstract Aim: To analyse the potential usefulness and clinical relevance of the assessment by echocardiography with left atrial strain, based on the myocardial atrial deformation curves with speckle-tracking velocity vector imaging (VVI), in the analysis of short-form recurrent atrial extra systoles in ambulatory patients not suffering from organic cardiopathy. Methods: We designed a descriptive, prospective, and observational study including 270 patients between the ages of 18 and 75 assessed during an outpatient cardiology consultation attended due to palpitations over a period of two years. Using ambulatory electrocardiographic monitoring, we selected cases with short forms of repetitive atrial extrasystole, isolated or recurrentatrial fibrillation and a control group formed by those patients without repetitive ectopia. All patients underwent a thorough echocardiographic study during their first cardiological visit. Results: The analysis of the dynamic curves segmental deformation generated after an atrial extrasystole can reveal different points of origin of the extrasystole and detect specific anatomical alterations in the interatrial conduction at the level of the Bachmann's fascicle showing different models of electro anatomical activation possibly involved in the appearance of repetitive forms. Higher values of dyssynchrony between the septal and lateral wall and elongation in the time of interatrial electromechanical conduction could also be related to the existence of repetitive ectopic beats. Conclusions: Our ambulatory study employing the left atrial longitudinal strain, particularly in its segmental analysis, provides new insights into its the usefulness and potential clinical relevance.


Resumen Objetivo: Analizar la utilidad y relevancia clínica de la evaluación mediante ecocardiografía basada en las curvas de deformación auricular miocárdica con imágenes vectoriales de velocidad (VVI) de speckle-tracking, en el análisis de las extrasístoles auriculares recurrentes de corta duración en pacientes ambulatorios sin cardiopatía orgánica. Métodos: Se diseñó un estudio descriptivo, prospectivo y observacional que incluyó a 270 pacientes de entre 18 y 75 años evaluados durante una consulta externa de cardiología a la que acudieron por palpitaciones durante un periodo de dos años. Mediante el uso de monitorización electrocardiográfica ambulatoria, se seleccionaron casos con formas cortas de extrasistolia auricular repetitiva, fibrilación auricular aislada o repetitiva y un grupo control formado por aquellos pacientes sin ectopia repetitiva. Todos los pacientes se sometieron a un estudio ecocardiográfico exhaustivo durante su primera visita cardiológica. Resultados: El análisis de las curvas dinámicas de deformación segmentaria generadas tras un extrasístole auricular diferentes modelos de activación electroanatómica posiblemente implicados en la aparición de formas repetitivas. Valores mayores de disincronía entre la pared septal y lateral y el alargamiento en el tiempo de conducción electromecánica intraauricular pudieran también relacionarse con la existencia de latidos ectópicos repetitivos. Conclusiones: Nuestro estudio ambulatorio empleando la deformación longitudinal auricular izquierda, particularmente en su análisis segmentario, proporciona nuevas perspectivas sobre su utilidad y potencial relevancia clínica.

2.
Arch Cardiol Mex ; 93(2): 172-182, 2023 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-36288196

RESUMO

Aim: To analyse the potential usefulness and clinical relevance of the assessment by echocardiography with left atrial strain, based on the myocardial atrial deformation curves with speckle-tracking velocity vector imaging (VVI), in the analysis of short-form recurrent atrial extra systoles in ambulatory patients not suffering from organic cardiopathy. Methods: We designed a descriptive, prospective, and observational study including 270 patients between the ages of 18 and 75 assessed during an outpatient cardiology consultation attended due to palpitations over a period of two years. Using ambulatory electrocardiographic monitoring, we selected cases with short forms of repetitive atrial extrasystole, isolated or recurrentatrial fibrillation and a control group formed by those patients without repetitive ectopia. All patients underwent a thorough echocardiographic study during their first cardiological visit. Results: The analysis of the dynamic curves segmental deformation generated after an atrial extrasystole can reveal different points of origin of the extrasystole and detect specific anatomical alterations in the interatrial conduction at the level of the Bachmann's fascicle showing different models of electro anatomical activation possibly involved in the appearance of repetitive forms. Higher values of dyssynchrony between the septal and lateral wall and elongation in the time of interatrial electromechanical conduction could also be related to the existence of repetitive ectopic beats. Conclusions: Our ambulatory study employing the left atrial longitudinal strain, particularly in its segmental analysis, provides new insights into its the usefulness and potential clinical relevance.


Objetivo: Analizar la utilidad y relevancia clínica de la evaluación mediante ecocardiografía basada en las curvas de deformación auricular miocárdica con imágenes vectoriales de velocidad (VVI) de speckle-tracking, en el análisis de las extrasístoles auriculares recurrentes de corta duración en pacientes ambulatorios sin cardiopatía orgánica. Métodos: Se diseñó un estudio descriptivo, prospectivo y observacional que incluyó a 270 pacientes de entre 18 y 75 años evaluados durante una consulta externa de cardiología a la que acudieron por palpitaciones durante un periodo de dos años. Mediante el uso de monitorización electrocardiográfica ambulatoria, se seleccionaron casos con formas cortas de extrasistolia auricular repetitiva, fibrilación auricular aislada o repetitiva y un grupo control formado por aquellos pacientes sin ectopia repetitiva. Todos los pacientes se sometieron a un estudio ecocardiográfico exhaustivo durante su primera visita cardiológica. Resultados: El análisis de las curvas dinámicas de deformación segmentaria generadas tras un extrasístole auricular diferentes modelos de activación electroanatómica posiblemente implicados en la aparición de formas repetitivas. Valores mayores de disincronía entre la pared septal y lateral y el alargamiento en el tiempo de conducción electromecánica intraauricular pudieran también relacionarse con la existencia de latidos ectópicos repetitivos. Conclusiones: Nuestro estudio ambulatorio empleando la deformación longitudinal auricular izquierda, particularmente en su análisis segmentario, proporciona nuevas perspectivas sobre su utilidad y potencial relevancia clínica.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Estudos Prospectivos , Sístole , Átrios do Coração/diagnóstico por imagem , Ecocardiografia/métodos
3.
Arq. bras. cardiol ; Arq. bras. cardiol;120(3): e20220077, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1429777

RESUMO

Resumo Fundamento A terapia de ressincronização cardíaca (TRC) pode beneficiar pacientes com insuficiência cardíaca (IC) avançada. O índice de excentricidade anormal por gated SPECT está relacionado a alterações estruturais e funcionais do ventrículo esquerdo (VE). Objetivo O objetivo do presente estudo foi avaliar a viabilidade do implante de eletrodos do VE guiado por análise de fase e sua relação com o remodelamento ventricular. Métodos Dezoito pacientes com indicação de TRC foram submetidos à cintilografia miocárdica para orientar o implante, avaliando-se os parâmetros de excentricidade e forma ventricular. P < 0,05 foi adotado como significância estatística. Resultados Na linha de base do estudo, a maioria dos pacientes foi classificada como NYHA 3 (n = 12). Após a TRC, 11 dos 18 pacientes foram reclassificados para um menor grau de limitação funcional. Além disso, a qualidade de vida dos pacientes melhorou após a TRC. Foram observadas reduções significativas na duração do QRS, intervalo PR, índice de forma diastólica final, índice de forma sistólica final, volume sistólico e massa miocárdica pós-TRC. O eletrodo do VE da TRC foi posicionado concordante, adjacente e discordante em 11 (61,1%), 5 (27,8%) e 2 (11,1%) pacientes, respectivamente. A excentricidade sistólica e diastólica final demonstrou remodelamento reverso após a TRC. Conclusões O implante de eletrodo do VE em TRC guiado por cintilografia gated SPECT é viável. A colocação do eletrodo concordante ou adjacente ao último segmento a se contrair foi um determinante do remodelamento reverso.


Abstract Background Cardiac resynchronization therapy (CRT) may benefit patients with advanced heart failure (HF). Abnormal eccentricity index by gated SPECT is related to structural and functional alterations of the left ventricle (LV). Objective The aim of this study is to evaluate the feasibility of LV lead implantation guided by phase analysis and its relationship to ventricular remodeling. Methods Eighteen patients with indication for CRT underwent myocardial scintigraphy for implant orientation, and eccentricity and ventricular shape parameters were evaluated. P < 0.05 was adopted as statistical significance. Results At baseline, most patients were classified as NYHA 3 (n = 12). After CRT, 11 out of 18 patients were reclassified to a lower degree of functional limitation. In addition, patients' quality of life was improved post-CRT. Significant reductions were observed in QRS duration, PR interval, end-diastolic shape index, end-systolic shape index, stroke volume, and myocardial mass post-CRT. The CRT LV lead was positioned concordant, adjacent, and discordant in 11 (61.1%), 5 (27.8%), and 2 (11.1%) patients, respectively. End-systolic and end-diastolic eccentricity demonstrated reverse remodeling post-CRT. Conclusions LV lead implantation in CRT guided by gated SPECT scintigraphy is feasible. The placement of the electrode concordant or adjacent to the last segment to contract was a determinant of reverse remodeling.

4.
Int J Cardiol ; 348: 102-107, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34890764

RESUMO

BACKGROUND: We aimed to identify, among Chronic Chagas Cardiomyopathy (CCC) patients with left ventricular dysfunction (LVD) and non-left bundle branch block (non-LBBB), subgroups with different functional and mechanical patterns of global longitudinal strain (GLS) and intraventricular dyssynchrony (IVD) at rest and after exercise stress test, and reclassify them using a new echocardiographic approach. METHODOLOGY: In this single-center cross-sectional study, 40 patients with CCC, left ventricular ejection fraction (LVEF) ≤ 35% and non-LBBB underwent rest echocardiography and then treadmill exercise stress echocardiography with GLS and IVD analysis. The sample was divided into four groups, based on GLS and IVD significant variation between rest and exercise: GLS + IVD+ (9 patients); GLS + IVD- (9 patients); GLS-IVD+ (10 patients); GLS-IVD- (10 patients). RESULTS: At rest, median LVEF was 28% (21.3%-33%) and GLS (-7% (-5%/-9.3%), were not different among groups. The average response of GLS was an increase of 0.74% over rest values, and the average response of IVD was a decrease of 6.9 ms. Group GLS-IVD+ presented more dyssynchrony at rest (p = 0.01). Left atrial (LA) volume (higher in GLS-IVD-) (p = 0.022) and TAPSE (higher in GLS + IVD+) (p = 0.015) were also different among groups at baseline. Of the 40 patients evaluated, 27 (67.5%) had very severe LVD (GLS < -8%). In addition, among these patients, 11 patients had contractile reserve after undergoing stress echocardiography. CONCLUSIONS: In patients with CCC, severe LVD and non-LBBB, the evaluation of GLS and IVD between rest and exercise was able to reclassify myocardial function and to identify subgroups with contractile reserve and significant dyssynchronopathy.


Assuntos
Cardiomiopatia Chagásica , Disfunção Ventricular Esquerda , Cardiomiopatia Chagásica/diagnóstico por imagem , Estudos Transversais , Ecocardiografia , Humanos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/epidemiologia , Função Ventricular Esquerda
5.
J Nucl Cardiol ; 29(3): 952-961, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33083983

RESUMO

BACKGROUND: Gated myocardial perfusion scintigraphy (GMPS) phase analysis is an important tool to investigate the physiology of left ventricular (LV) dyssynchrony. We aimed to test the performance of GMPS LV function and phase analysis in different clinical settings and on a diverse population. METHODS: This is a post hoc analysis of a prospective, non-randomized, multinational, multicenter cohort study. Clinical evaluation and GMPS prior to cardiac resynchronization therapy (CRT)(baseline) and 6-month post CRT (follow-up) were done. LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV), LV ejection fraction (LVEF), LV phase standard deviation (LVPSD), and percentage of left ventricle non-viable (PLVNV) were obtained by 10 centers and compared to the core lab. RESULTS: 276 GMPS studies had all data available from individual sites and from core lab. There were no statistically significant differences between all variables except for LVPSD. When subjects with no mechanical dyssynchrony were excluded, LVPSD difference became non-significant. LVESV, LVEF, LVPSD and PLVNV had strong correlation in site against core lab comparison. Bland-Altman plots demonstrated good agreement. CONCLUSIONS: The presented correlation and agreement of LV function and dyssynchrony analysis over different sites with a diverse sample corroborate the strength of GMPS in the management of heart failure in clinical practice.


Assuntos
Disfunção Ventricular Esquerda , Estudos de Coortes , Humanos , Perfusão , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Disfunção Ventricular Esquerda/diagnóstico por imagem
6.
J Nucl Cardiol ; 29(3): 1166-1174, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33152098

RESUMO

PURPOSE: We sought to evaluate the behavior of cardiac mechanical synchrony as measured by phase SD (PSD) derived from gated MPI SPECT (gSPECT) in patients with super-response after CRT and to evaluate the clinical and imaging characteristics associated with super-response. METHODS: 158 subjects were evaluated with gSPECT before and 6 months after CRT. Patients with an improvement of LVEF > 15% and NYHA class I/II or reduction in LV end-systolic volume > 30% and NYHA class I/II were labeled as super-responders (SR). RESULTS: 34 patients were classified as super-responders (22%) and had lower PSD (32° ± 17°) at 6 months after CRT compared to responders (45° ± 24°) and non-responders 46° ± 28° (P = .02 for both comparisons). Regression analysis identified predictors independently associated with super-response to CRT: absence of previous history of CAD (odds ratio 18.7; P = .002), absence of diabetes mellitus (odds ratio 13; P = .03), and history of hypertension (odds ratio .2; P = .01). CONCLUSION: LV dyssynchrony after CRT implantation, but not at baseline, was significantly better among super-responders compared to non-super-responders. The absence of diabetes, absence of CAD, and history of hypertension were independently associated with super-response after CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Hipertensão , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Hipertensão/complicações , Razão de Chances , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Resultado do Tratamento
7.
Discoveries (Craiova) ; 9(2): e128, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34849395

RESUMO

BACKGROUND: Permanent right ventricular apical pacing may have negative effects on ventricular function and contribute to development of heart failure. We aimed to assess intra- and interventricular mechanical dyssynchrony in patients with permanent right ventricular apical pacing, and to establish electrocardiographic markers of dyssynchrony. METHODS: 84 patients (46:38 male:female) who required permanent pacing were studied. Pacing was done from right ventricular apex in all patients. We measured QRS duration and dispersion on standard 12-lead ECG. Intra- and interventricular mechanical dyssynchrony and left ventricular ejection fraction were assessed by transthoracic echocardiography. Patients were followed-up for 24 months.  Results: Six months after implantation, QRS duration increased from 128.02 ms to 132.40 ms, p≤0.05. At 24 months, QRS dispersion increased from 43.26 ms to 46.13 ms, p≤0.05. Intra- and interventricular dyssynchrony increased and left ventricular ejection fraction decreased during follow-up. A QRS dispersion of 47 ms predicted left ventricular dysfunction and long-term electromechanical dyssynchrony with a sensitivity of 80% and a specificity of 76%.  Conclusion: In patients with permanent right ventricular apical pacing there is an increased duration and dispersion of QRS related to dyssynchrony and decreased left ventricular ejection fraction. This study shows that QRS dispersion could be a better predictive variable than QRS duration for identifying left ventricular ejection fraction worsening in patients with permanent right ventricular apical pacing. The electrocardiogram is a simple tool for predicting systolic function worsening in these patients and can be used at the bedside for early diagnosis in the absence of clinical symptoms, allowing adjustments of medical treatment to prevent progression of heart failure and improve the patient's quality of life.

8.
J Interv Card Electrophysiol ; 62(3): 479-485, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34014454

RESUMO

INTRODUCTION: Electrical transmission disorders have a deleterious effect on cardiac depolarization, resulting in a disorganized ventricular contraction that reduces global mechanical efficiency; this mechanical dyssynchrony can be corrected by cardiac resynchronization therapy. However, despite adjustments in the electrical criteria selection of QRS for the recognition of mechanical dyssynchrony, a significant proportion of patients do not currently respond to this therapy. PURPOSE: To find if a new predictor of dyssynchrony, the electrocardiogram spatial variance, is a better marker of mechanical dyssynchrony than QRS duration. METHODS: Forty-seven electrocardiograms and 47 strain (2D speckle tracking) echocardiograms were prospectively collected simultaneously in consecutive, non-selected patients; the left ventricular mechanical dispersion was measured in all the cases. The electrocardiographic analysis of variance was made with a digital superposition of the electrocardiographic leads and generates different indexes of variance of both QRS complex and repolarization phase. RESULTS: ROC analysis probed that the best area under the curve (AUC) value correlated with left ventricular mechanical dispersion and was obtained combining several spatial variance markers (considering depolarization and repolarization spatial variance together; AUC = 0.97); the same analysis using the QRS duration versus mechanical dispersion showed a significantly lower AUC value (AUC = 0.64). CONCLUSION: Spatial variance combining depolarization and repolarization markers is a superior predictor of left ventricular mechanical dispersion than QRS duration.


Assuntos
Terapia de Ressincronização Cardíaca , Disfunção Ventricular Esquerda , Ecocardiografia , Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/terapia
9.
Int J Cardiovasc Imaging ; 37(5): 1789-1798, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33442855

RESUMO

Transient alterations in ventricular conduction and synchronized cardiac performance have been reported in experimental models of myocardial ischemia. In post-stress 99mTc-sestamibi-gated-SPECT myocardial perfusion imaging (MPI), the time elapsed between tracer injection and image acquisition could influence the detection of ischemic left ventricular mechanical dyssynchrony (LVMD). We aimed at evaluating whether early vs. delayed post-stress MPI improve ischemic LVMD detection using the phase analysis parameters standard deviation (SD) and histogram bandwidth (HB) and to assess the correlation between stress-induced changes in SD and HB and other functional parameters. We prospectively studied 32 control subjects (Group-1) and 60 ischemic patients (Group-2). Stress-induced changes were calculated as stress minus rest (Δ). LVMD was defined as post-stress increases of either SD or HB. Group-2 showed higher ΔSD and ΔHB in early than in delayed images: early ΔSD: 1.63 (- 0.37 to 4.83) vs. delayed ΔSD: - 0.39 (- 3.82 to 1.74); early ΔHB: 2.50 (- 4 to 12) vs. ΔHB delayed: - 4 (- 15.75 to 4), all p < 0.01. ΔSD and ΔHB correlated linearly with ΔLV-ejection-fraction (EF) and ΔLV-end systolic-volume (ESV) in early images, all p < 0.01. Early images detected LVMD in more patients than delayed scans (78% vs. 38%; p < 0.01) All patients with LVEF drop in early post-stress evaluation had LVMD. Early post-stress images improve ischemic LVMD detection. Ischemic LVEF and LVESV changes correlate with ΔSD and ΔHB.


Assuntos
Imagem de Perfusão do Miocárdio , Disfunção Ventricular Esquerda , Eletrocardiografia , Humanos , Valor Preditivo dos Testes , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia
10.
J Nucl Cardiol ; 28(4): 1413-1421, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-31410734

RESUMO

BACKGROUND: Left ventricular diastolic dyssynchrony (LVDD) can be assessed by gated myocardial perfusion single-photon emission computed tomography (GMP-SPECT). LVDD is an area of interest in subjects who underwent cardiac resynchronization therapy (CRT). The aim of this post hoc analysis was to assess the role of LVDD in subjects with CRT who were followed up at 6-month period. MATERIAL & METHODS: Left ventricular diastolic dyssynchrony was assessed by GMP-SPECT at baseline and after CRT procedure in 160 subjects from 10 different cardiological centers. CRT procedure was performed as per current guidelines. Outcomes were defined as improvement in ≥1 New York Heart Association (NYHA) class, left ventricular ejection fraction (LVEF) by 5%, and reduction in end-systolic volume (ESV) by 15% and 5% points in Minnesota Living with Heart Failure Questionnaire. LVDD was defined as diastolic phase standard deviation ≥40 ± 14°. RESULTS: Improvement in NYHA functional class occurred in 105 (65.6%), LVEF in 74 (46.3%), decrease in ESV in 86 (53.8%), and Minnesota score in 85 (53.1%) cases. Baseline LV diastolic standard deviation was 53.53° ± 20.85 and at follow-up 40.44° ± 26.1283; (P < 0.001). LVDD was not associated with improvement in clinical outcomes at follow-up. CONCLUSION: CRT improves both systolic and diastolic dyssynchrony values at 6-month follow-up. LVDD at baseline is correlated with cardiac functionality at follow-up, but not with overall favorable clinical outcomes.


Assuntos
Terapia de Ressincronização Cardíaca , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Imagem de Perfusão do Miocárdio , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Diástole , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/terapia
11.
J Nucl Cardiol ; 28(3): 1055-1063, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31267412

RESUMO

BACKGROUND: To detect ischemia in patients with angina and normal coronaries frequently represents a complex diagnosis. METHODS: To investigate whether left ventricular mechanical dyssynchrony by phase analysis contributes in the evaluation of patients with chest pain and normal coronaries, gated-SPECT myocardial perfusion imaging (MPI) at rest and 30 minutes post-stress was performed in 218 patients with normal epicardial coronaries, who were divided into two groups: those with summed difference score (SDS) ≥ 4 (54 patients, Group 1), and those with SDS < 4 (164 patients, Group 2). Intraventricular synchronism-phase standard deviation (PSD) and histogram bandwidth (HBW)-was evaluated by phase analysis. RESULTS: Women were significantly more frequent in Group 2 (those without ischemia in SPECT MPI): 113 (69%) vs 25 (46%), P = .00001. In males, left ventricular ejection fraction (LVEF) and ventricular volumes were not significantly different between patients with or without ischemia. However, ischemic females showed significantly higher ventricular volumes, minor post-stress LVEF and more negative delta LVEF (- 3.9 vs 0.34, P = .0008) than the non-ischemic ones. There was a significant post-stress increase of PSD and HBW among males, although not among females. According to SSS (≥ 4, with ischemia/necrosis; < 4, without ischemia/necrosis), post-stress PSD and HBW significantly increase both in male and female, and PSD and HBW were significantly higher in females with SSS ≥ 4 compared to those with SSS < 4 (PSD rest: 19.04° vs 11.72°, P < .0001; HBW rest: 58.85° vs 38.21°, P < .0001). PSD and HBW were also higher among males with SSS ≥ 4 compared to those with SSS < 4, although not significantly. CONCLUSION: Higher ventricular volumes in females and dyssynchrony are associated with inducible ischemia in MPI in patients with chest pain and normal coronaries. Stress-induced ischemia increases degree of dyssynchrony.


Assuntos
Angina Pectoris/diagnóstico por imagem , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Imagem de Perfusão do Miocárdio , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Angina Pectoris/etiologia , Angina Pectoris/fisiopatologia , Estudos Transversais , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio , Fatores Sexuais , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia
12.
J Nucl Cardiol ; 28(1): 55-64, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-30684258

RESUMO

BACKGROUND: Placing the left ventricular (LV) lead in a viable segment with the latest mechanical activation (vSOLA) may be associated with optimal cardiac resynchronization therapy (CRT) response. We assessed the role of gated SPECT myocardial perfusion imaging (gSPECT MPI) in predicting clinical outcomes at 6 months in patients submitted to CRT. METHODS: Ten centers from 8 countries enrolled 195 consecutive patients. All underwent gSPECT MPI before and 6 months after CRT. The procedure was performed as per current guidelines, the operators being unaware of gSPECT MPI results. Regional LV dyssynchrony (Phase SD) and vSOLA were automatically determined using a 17 segment model. The lead was considered on-target if placed in vSOLA. The primary outcome was improvement in ≥1 of the following: ≥1 NYHA class, left ventricular ejection fraction (LVEF) by ≥5%, reduction in end-systolic volume by ≥15%, and ≥5 points in Minnesota Living With Heart Failure Questionnaire (MLHFQ). RESULTS: Sixteen patients died before the follow-up gSPECT MPI. The primary outcome occurred in 152 out of 179 (84.9%) cases. Mean change in LV phase standard deviation (PSD) at 6 months was 10.5°. Baseline dyssynchrony was not associated with the primary outcome. However, change in LV PSD from baseline was associated with the primary outcome (OR 1.04, 95% CI 1.01-1.07, P = .007). Change in LV PSD had an AUC of 0.78 (0.66-0.90) for the primary outcome. Improvement in LV PSD of 4° resulted in the highest positive likelihood ratio of 7.4 for a favorable outcome. In 23% of the patients, the CRT lead was placed in the vSOLA, and in 42% in either this segment or in a segment within 10° of it. On-target lead placement was not significantly associated with the primary outcome (OR 1.53, 95% CI 0.71-3.28). CONCLUSION: LV dyssynchrony improvement by gSPECT MPI, but not on-target lead placement, predicts clinical outcomes in patients undergoing CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Imagem de Perfusão do Miocárdio , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Resultado do Tratamento
13.
Medicina (B.Aires) ; Medicina (B.Aires);80(6): 726-728, dic. 2020. graf
Artigo em Espanhol | LILACS | ID: biblio-1250303

RESUMO

Resumen La disfunción ventricular secundaria a disincronía eléctrica y mecánica es una complicación de la estimulación ventricular desde el ápex del ventrículo derecho. No existen informes de disincronía secundaria a los efectos de fármacos antiarrítmicos. Se presenta el caso de una niña de 10 días de vida con taquicardia supraventricular incesante que se internó en terapia intensiva neonatal. Se inició tratamiento con propranolol por vía oral y ante la persistencia de la taquicardia se agregó amiodarona endovenosa. La paciente estuvo predominantemente en taquicardia con frecuencias cardíacas entre 200 y 290 latidos por minuto durante una semana a pesar del tratamiento instaurado. La función ventricular fue normal en los ecocardiogramas realizados. Se agregó flecainida por vía oral al esquema de tratamiento y luego de 24 horas presentó una taquicardia más lenta con QRS ancho e imagen de bloqueo completo de rama izquierda. Un nuevo ecocardiograma evidenció deterioro de la función ventricular izquierda e insuficiencia mitral moderada lo que motivó la suspensión de la flecainida y el propranolol. A las 24 horas de la suspensión se observó la normalización de la función ventricular a pesar de la persistencia de episodios intermitentes de taquicardia. Se reinició el propranolol logrando el control de la taquicardia. La presencia de disincronía ventricular generada por el bloqueo de rama izquierda secundario al tratamiento farmacológico con flecainida constituye una novedosa explicación posible para el desarrollo de disfunción ventricular.


Abstract Ventricular dysfunction secondary to electrical and mechanical dyssynchrony in chronic right ventricular apical pacing is a well-recognized complication. There are no previous reports of pharmacologically induced dyssynchrony. A 10-day old infant with incessant supraventricular tachycardia was admitted to the neonatal intensive care unit. Therapy with oral propranolol was initiated and due to persistence of tachycardia intravenous amiodarone was administered. The patient remained predominantly in tachycardia with heart rates between 200-290 beats per minute for a week with serial echocardiograms showing preserved ventricular function. Oral flecainide was started. After 24 hours of treatment the patient developed a slower incessant wide QRS with a left bundle branch block pattern. The echocardiogram showed deterioration of left ventricular systolic function and moderate mitral regurgitation. Flecainide and propranolol were discontinued. The QRS complex narrowed and despite intermittent breakthroughs of supraventricular tachycardia, ventricular function normalized. Propranolol was restarted to achieve definitive control of the tachycardia. The presence of ventricular dyssynchrony generated by the left bundle branch block pattern secondary to pharmacological treatment with flecainide is a novel possible explanation for the development of ventricular dysfunction.


Assuntos
Humanos , Recém-Nascido , Lactente , Taquicardia Supraventricular/induzido quimicamente , Taquicardia Supraventricular/tratamento farmacológico , Preparações Farmacêuticas , Bloqueio de Ramo , Eletrocardiografia , Ventrículos do Coração
14.
Medicina (B Aires) ; 80(6): 726-728, 2020.
Artigo em Espanhol | MEDLINE | ID: mdl-33254125

RESUMO

Ventricular dysfunction secondary to electrical and mechanical dyssynchrony in chronic right ventricular apical pacing is a well-recognized complication. There are no previous reports of pharmacologically induced dyssynchrony. A 10-day old infant with incessant supraventricular tachycardia was admitted to the neonatal intensive care unit. Therapy with oral propranolol was initiated and due to persistence of tachycardia intravenous amiodarone was administered. The patient remained predominantly in tachycardia with heart rates between 200-290 beats per minute for a week with serial echocardiograms showing preserved ventricular function. Oral flecainide was started. After 24 hours of treatment the patient developed a slower incessant wide QRS with a left bundle branch block pattern. The echocardiogram showed deterioration of left ventricular systolic function and moderate mitral regurgitation. Flecainide and propranolol were discontinued. The QRS complex narrowed and despite intermittent breakthroughs of supraventricular tachycardia, ventricular function normalized. Propranolol was restarted to achieve definitive control of the tachycardia. The presence of ventricular dyssynchrony generated by the left bundle branch block pattern secondary to pharmacological treatment with flecainide is a novel possible explanation for the development of ventricular dysfunction.


La disfunción ventricular secundaria a disincronía eléctrica y mecánica es una complicación de la estimulación ventricular desde el ápex del ventrículo derecho. No existen informes de disincronía secundaria a los efectos de fármacos antiarrítmicos. Se presenta el caso de una niña de 10 días de vida con taquicardia supraventricular incesante que se internó en terapia intensiva neonatal. Se inició tratamiento con propranolol por vía oral y ante la persistencia de la taquicardia se agregó amiodarona endovenosa. La paciente estuvo predominantemente en taquicardia con frecuencias cardíacas entre 200 y 290 latidos por minuto durante una semana a pesar del tratamiento instaurado. La función ventricular fue normal en los ecocardiogramas realizados. Se agregó flecainida por vía oral al esquema de tratamiento y luego de 24 horas presentó una taquicardia más lenta con QRS ancho e imagen de bloqueo completo de rama izquierda. Un nuevo ecocardiograma evidenció deterioro de la función ventricular izquierda e insuficiencia mitral moderada lo que motivó la suspensión de la flecainida y el propranolol. A las 24 horas de la suspensión se observó la normalización de la función ventricular a pesar de la persistencia de episodios intermitentes de taquicardia. Se reinició el propranolol logrando el control de la taquicardia. La presencia de disincronía ventricular generada por el bloqueo de rama izquierda secundario al tratamiento farmacológico con flecainida constituye una novedosa explicación posible para el desarrollo de disfunción ventricular.


Assuntos
Preparações Farmacêuticas , Taquicardia Supraventricular , Bloqueio de Ramo , Eletrocardiografia , Ventrículos do Coração , Humanos , Lactente , Recém-Nascido , Taquicardia Supraventricular/induzido quimicamente , Taquicardia Supraventricular/tratamento farmacológico
15.
EJNMMI Res ; 10(1): 125, 2020 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-33079263

RESUMO

PURPOSE: To analyze the evolution post-cardiac resynchronization therapy (CRT) in left ventricular non-compaction (LVNC) cardiomyopathy (CM) patients compared to other types of CM, according to clinical and functional variables, by using gated-SPECT myocardial perfusion imaging (MPI). METHODS: Ninety-three patients (60 ± 11 years, 28% women) referred for pre-CRT assessment were studied and divided into three groups: 1 (non-ischemic CM with LVNC, 11 patients), 2 (ischemic CM, 28 patients), and 3 (non-ischemic CM, 53 patients). All were studied by a 99mTc-MIBI gated-SPECT MPI at rest pre-CRT implantation and 6 ± 1 months after, including intraventricular dyssynchrony assessment by phase analysis. Quality of life was measured by the Minnesota Living with Heart Failure Questionnaire (MLHFQ). RESULTS: No differences in sex, atherosclerotic risk factors other than smoking habit, and MLHFQ results were found among groups. LVNC CM patients were younger, with greater QRS width and lower left ventricular ejection fraction (LVEF) at baseline, but the differences were not significant. No significant differences were found at baseline regarding ventricular function, although end-systolic volume was slightly higher in LVNC CM patients. Mean SRS was significantly higher (p < 0.0001) in ischemic patients (14.9) versus non-ischemic ones (8.7 in group 1 and 9 in group 2). At baseline, LVNC CM patients were significantly more dyssynchronous: Their phase standard deviation (PSD) was higher (89.5° ± 14.2°) versus groups 2 (65.2° ± 23.3°) and 3 (69.7° ± 21.7°), p = 0.007. Although the quality of life significantly improved in all groups, non-ischemic patients (with or without LVNC) showed a higher LVEF increase and volumes reduction at 6 months post-CRT. Dyssynchrony reduced post-CRT in all groups. Nevertheless, those more dyssynchronous at baseline (LVNC CM) exhibited the most significant intraventricular synchronism improvement: PSD was reduced from 89.5° ± 14.2° at baseline to 63.7° ± 20.5° post-CRT (p = 0.028). Six months post-CRT, 89% of patients were responders: 11 (100%) of those with LVNC CM, 25 (86%) of those with ischemic CM, and 47 (89%) of patients with non-ischemic CM. No patient with LVNC CM had adverse events during the follow-up. CONCLUSION: CRT contributes to a marked improvement in non-ischemic CM patients with non-compaction myocardium. Phase analysis in gated-SPECT MPI is a valuable tool to assess the response to CRT.

16.
Arch Cardiol Mex ; 90(3): 328-335, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32952162

RESUMO

La estimulación apical permanente del ventrículo derecho (VD) puede producir asincronía del ventrículo izquierdo (VI) desde los puntos de vista eléctrico y mecánico. Este fenómeno es efecto de una alteración de la activación normal del VI que lleva al deterioro de la función sistólica y la aparición de insuficiencia cardíaca y sus efectos deletéreos relacionados. Para el estudio de la asincronía eléctrica del VI se ha propuesto en fecha reciente el nuevo sistema electrocardiográfico no invasivo Synchromax, que puede cuantificar el grado de asincronía eléctrica que causa una subsecuente asincronía mecánica. Esta última se ha estudiado casi siempre mediante la ecocardiografía transtorácica bidimensional (ETT2D) a través del Doppler tisular y la deformación miocárdica y ahora con la ecocardiografía tridimensional transtorácica en tiempo real (E3DTR). La relación entre estos fenómenos ha sido motivo de estudio a fin de identificar a los pacientes que se benefician de la transición a un tratamiento de resincronización cardíaca. Conclusiones: La estimulación artificial permanente del VD produce asincronía eléctrica del VI que puede cuantificarse mediante el nuevo sistema electrocardiográfico Synchromax y desencadenar asincronía mecánica estudiada mediante la ecocardiografía transtorácica para reconocer a los pacientes que pueden beneficiarse de un tratamiento de resincronización cardíaca.Permanent apical pacing of right ventricle (RV) can produce dyssynchrony of the left ventricle (LV) from an electrical and mechanical point of view. This phenomenon is caused by an alteration in the normal activation of LV leading to a deterioration of systolic function and the appearance of heart failure and its associated deleterious effects. For the study of the electrical asynchrony of the LV, a new noninvasive electrocardiographic system Synchromax has recently been proposed, being able to quantify the degree of electrical asynchrony that leads to a subsequent mechanical dyssynchrony. Th e latter has been traditionally studied by two-dimensional transthoracic echocardiography (2DTTE) through tissue Doppler and myocardial deformation and lately by real-time 3-dimensional echocardiography (RT3DE). The relationship between these phenomena has been the subject of study to predict those patients who benefit from an "upgrade" to cardiac resynchronization therapy. Conclusions: Permanent apical pacing of the RV produces electrical dyssynchrony of the LV that can be quantified using a new electrocardiographic system Synchromax and trigger mechanical asynchrony studied through transthoracic echocardiography allowing to predict those patients who benefit from cardiac resynchronization therapy.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Disfunção Ventricular Esquerda/etiologia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia , Ecocardiografia Doppler , Ecocardiografia Tridimensional , Humanos , Disfunção Ventricular Esquerda/diagnóstico por imagem
17.
Arch. cardiol. Méx ; Arch. cardiol. Méx;90(3): 328-335, Jul.-Sep. 2020. graf
Artigo em Espanhol | LILACS | ID: biblio-1131051

RESUMO

Resumen La estimulación apical permanente del ventrículo derecho (VD) puede producir asincronía del ventrículo izquierdo (VI) desde los puntos de vista eléctrico y mecánico. Este fenómeno es efecto de una alteración de la activación normal del VI que lleva al deterioro de la función sistólica y la aparición de insuficiencia cardíaca y sus efectos deletéreos relacionados. Para el estudio de la asincronía eléctrica del VI se ha propuesto en fecha reciente el nuevo sistema electrocardiográfico no invasivo Synchromax, que puede cuantificar el grado de asincronía eléctrica que causa una subsecuente asincronía mecánica. Esta última se ha estudiado casi siempre mediante la ecocardiografía transtorácica bidimensional (ETT2D) a través del Doppler tisular y la deformación miocárdica y ahora con la ecocardiografía tridimensional transtorácica en tiempo real (E3DTR). La relación entre estos fenómenos ha sido motivo de estudio a fin de identificar a los pacientes que se benefician de la transición a un tratamiento de resincronización cardíaca. Conclusiones: La estimulación artificial permanente del VD produce asincronía eléctrica del VI que puede cuantificarse mediante el nuevo sistema electrocardiográfico Synchromax y desencadenar asincronía mecánica estudiada mediante la ecocardiografía transtorácica para reconocer a los pacientes que pueden beneficiarse de un tratamiento de resincronización cardíaca.


Abstract Permanent apical pacing of right ventricle (RV) can produce dyssynchrony of the left ventricle (LV) from an electrical and mechanical point of view. This phenomenon is caused by an alteration in the normal activation of LV leading to a deterioration of systolic function and the appearance of heart failure and its associated deleterious effects. For the study of the electrical asynchrony of the LV, a new noninvasive electrocardiographic system Synchromax has recently been proposed, being able to quantify the degree of electrical asynchrony that leads to a subsequent mechanical dyssynchrony. The latter has been traditionally studied by two-dimensional transthoracic echocardiography (2DTTE) through tissue Doppler and myocardial deformation and lately by real-time 3-dimensional echocardiography (RT3DE). The relationship between these phenomena has been the subject of study to predict those patients who benefit from an “upgrade” to cardiac resynchronization therapy. Conclusions: Permanent apical pacing of the RV produces electrical dyssynchrony of the LV that can be quantified using a new electrocardiographic system Synchromax and trigger mechanical asynchrony studied through transthoracic echocardiography allowing to predict those patients who benefit from cardiac resynchronization therapy.


Assuntos
Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Disfunção Ventricular Esquerda/etiologia , Ecocardiografia , Estimulação Cardíaca Artificial/métodos , Ecocardiografia Doppler , Disfunção Ventricular Esquerda/diagnóstico por imagem , Ecocardiografia Tridimensional , Terapia de Ressincronização Cardíaca/métodos
18.
J Nucl Cardiol ; 27(4): 1158-1167, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32246407

RESUMO

BACKGROUND: Left ventricular contraction dyssynchrony (LVCD) has been related to induced ischemia and transmural scar but the interplay of myocardial viability and dyssynchrony is unknown. The aim of the present study was to establish the role of dyssynchrony in the context of a viability study performed with nitrate augmentation gated single photon emission computed tomography (GSPECT) myocardial perfusion imaging (MPI). METHODS: Fifty-four consecutive patients with ischemic dilated cardiomyopathy (IDC) and depressed left ventricular ejection fraction (LVEF) were included. They underwent a two-day rest/nitroglycerine (NTG) study GSPECT MPI to determine the myocardial viability. Patients with a nitrate-induced uptake increase of > 10% vs baseline, in at least, two consecutive dysfunctional segments were considered viable as well as those who showed no improvement in the uptake but the uptake was > 50% on post NTG study. Patients with no nitrate-induced uptake increase of > 10% and the uptake of < 50% were considered non-viable. Perfusion, function and LVCD were compared in 25 viable patients vs 29 non-viable patients at baseline and after NTG administration. RESULTS: After NTG administration, in the viable group, the LVEF increased (36.44 ± 6.64% vs 39.84 ± 6.39%) and the end-systolic volume decreased significantly (119.28 ± 31.77 mL vs 109.08 ± 33.17 mL) (P < 0.01). These patients also experienced a significant reduction in the LVCD variables: phase standard deviation was reduced in the post NTG study (57.77° ± 19.47° vs 52.02° ± 17.09°) as well as the phase histogram bandwidth (190.20° ± 78.83° vs 178.0° ± 76.14°) (P < 0.05). Functional and LVCD variables remained similar in the non-viable patients (P > 0.05). CONCLUSION: In patients with IDC and depressed LVEF, the myocardial viability detected by rest/ NTG GSPECT MPI, might determine LVCD improvement.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Cardiomiopatia Dilatada/fisiopatologia , Contração Miocárdica/fisiologia , Isquemia Miocárdica/fisiopatologia , Imagem de Perfusão do Miocárdio/métodos , Função Ventricular Esquerda/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
19.
Insuf. card ; 15(1): 2-9, mar. 2020. ilus, tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1124856

RESUMO

Introducción. En el complejo universo de la falla cardíaca, el pronóstico y el tratamiento de la misma sumaron un aspecto de valor durante la última década del siglo pasado, a partir del reconocimiento de la disincronía mecánica durante la sístole y las consiguientes propuestas de resincronización cardíaca. Desde los inicios la predicción de disincronía mecánica se ha fundamentado en la duración del complejo QRS, las imágenes y más recientemente el análisis del índice de varianza del QRS. Objetivo. Tomando como estándar la dispersión mecánica ventricular izquierda medida por ecocardiografía, valorar la concordancia entre duración promedio del QRS del electrocardiograma (ECG) versus el índice de varianza, en cuanto a sensibilidad, especificidad y valor predictivo de dispersión anormal. Métodos. Población de pacientes consecutivos citados para ecocardiografía strain, sin escara ventricular, para medir dispersión mecánica, duración promedio del QRS del ECG e índice de varianza espacial. Resultados. Se evaluaron 54 pacientes y 57 escenarios distintos. Edad promedio: 66,3±14,2 años; duración promedio del QRS fue de 119,7±31,5 mseg. El índice de varianza promedio fue 0,52±0,35. Un índice de varianza >0,4 demostró sensibilidad y especificidad de 82,6% y 64,7% respectivamente, para diagnóstico de dispersión mecánica anormal (e"56 mseg); valor predictivo positivo: 61,3%, negativo: 84,6%. La duración promedio de QRS e"130 mseg logró sensibilidad y especificidad de 52,6% y 71%, con valores predictivos positivo y negativo de 54,5% y 68,6%, respectivamente. La duración promedio del QRS no guarda dependencia con la disincronía mecánica (p=0,1458); la disincronía mecánica (>56 mseg) y la electrocardiografía de varianza, por otra parte, sí guardan dependencia muy significativa (p=0,0012). Los métodos no son comparables para diagnosticar disincronía (kappa=0,376). Conclusión. El ECG de varianza tiene mejor sensibilidad y valor predictivo negativo para el diagnóstico de dispersión mecánica ventricular izquierda valorada por ecocardiografía.


Introduction. The prediction of mechanical dyssynchrony has generally been based on the duration of the QRS complex, although other resources are available, such as the QRS variance index; these methods have not been compared with each other. Objective. Taking as a standard the left ventricular mechanical dispersion measured by speckle-tracking strain echocardiography, to assess the concordance between the average QRS duration of the standard electrocardiogram versus the spatial variance index in terms of sensitivity, specificity and predictive value of abnormal mechanical dispersion. Methods. Population of consecutive patients cited for strain echocardiography and without ventricular scar tissue, to measure mechanical dispersion, average QRS duration of the standard electrocardiogram and the variance index. Results. Fifty-four patients and 57 different scenarios were evaluated; the average age was 66.3±14.2 years, the QRS average duration on standard electrocardiogram was 119.7±31.5 ms. Average ID was 0.52±0.35. A spatial variation index >0.4 showed sensitivity and specificity of 82.6% and 64.7% respectively, for the diagnosis of abnormal mechanical dispersion (e"56 ms); positive predictive value: 61.3%, negative: 84.6%. The average duration of QRS e"130 ms achieved sensitivity and specificity of 52.6% and 71%, and the positive and negative predictive values were 54.5 and 68.6%, respectively. The average QRS duration are not interdependent with mechanical dyssynchrony (p=0.1458); mechanical dyssynchrony (>56 ms) and spatial variance electrocardiography are, nevertheless, clearly interdependent (p=0.0012). The methods are not comparable between them (kappa=0.376). Conclusion. The QRS variation electrocardiogram has better sensitivity and negative predictive value respect to the average QRS duration for the diagnosis of left ventricular mechanical dispersion prevalence, measured by echocardiography.


Introdução. No complexo universo da insuficiência cardíaca, seu prognóstico e tratamento agregaram valor durante a última década do século passado, com base no reconhecimento da dissincronia mecânica durante a sístole e nas propostas subsequentes de ressincronização cardíaca. Desde o início, a previsão da dissincronia mecânica tem sido baseada na duração do complexo QRS, nas imagens e, mais recentemente, na análise do índice de variância QRS. Objetivo. Tomando como padrão a dispersão mecânica do ventrículo esquerdo medida pelo ecocardiograma, avalie a concordância entre a duração média do QRS do eletrocardiograma (ECG) versus o índice de variância, em termos de sensibilidade, especificidade e valor preditivo de dispersão anormal. Métodos População de pacientes consecutivos citados para ecocardiograma de deformação, sem escara ventricular, para medir dispersão mecânica, duração média do QRS do ECG e índice de variância espacial. Resultados. Foram avaliados 54 pacientes e 57 cenários diferentes. Idade média: 66,3±14,2 anos; a duração média do QRS foi de 119,7±31,5 mseg. O índice de variância médio foi de 0,52±0,35. Um índice de variância >0,4 mostrou sensibilidade e especificidade de 82,6% e 64,7%, respectivamente, para diagnóstico de dispersão mecânica anormal (e"56 mseg); valor preditivo positivo: 61,3%, negativo: 84,6%. A duração média do QRS e"130 mseg alcançou sensibilidade e especificidade de 52,6% e 71%, com valores preditivos positivos e negativos de 54,5% e 68,6%, respectivamente. A duração média do QRS não depende de dissincronia mecânica (p=0,1458); dissincronia mecânica (>56 mseg) e eletrocardiografia de variância, por outro lado, têm dependência muito significativa (p=0,0012). Os métodos não são comparáveis para diagnosticar dissincronia (kappa=0,376). Conclusão. A variância do ECG apresenta melhor sensibilidade e valor preditivo negativo para o diagnóstico de dispersão mecânica do ventrículo esquerdo avaliada pelo ecocardiograma.

20.
Echocardiography ; 37(2): 293-301, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31957094

RESUMO

BACKGROUND: Fabry disease (FD) is a rare X-linked storage disorder caused by deficiency of the lysosomal enzyme α-galactosidase A, and it typically causes multiorgan dysfunction. The main cause of death is heart disease resulting from left ventricular (LV) diastolic dysfunction, LV systolic dysfunction, severe LV hypertrophy (LVH), and sudden death. In several cardiac disorders, LV systolic dysfunction and ventricular arrhythmias are associated with mechanical dispersion (MD). MD has until now not been studied in patients with FD. OBJECTIVE: To investigate the prevalence of MD in patients with FD. METHODS: Complete echocardiographic data and speckle tracking echocardiographic data were collected. MD is an index of inter-segmental discoordination of contraction and is defined as the standard deviation (SD) of the time-to-peak longitudinal negative strain in 17 LV segments with a value >49 milliseconds. Patients with FD were divided into the following 2 groups: group I (patients with FD but no LVH, n = 64) and group II (patients with FD and LVH, n = 25). These groups were compared with a group of healthy subjects (group III, n = 50). Parametric variables were expressed as mean ± SD, and nonparametric variables were expressed as median and inter-quartile range. A P value <.05 was considered significant. RESULTS: A total of 113 patients with FD were included in this study. Of these, 24 (21%) were excluded because of poor imaging quality or presence of comorbidities, and the final study population consisted of 89 patients (mean age of 33.5 ± 14.5 years, 64% female). Group II patients were older than group I patients (46 ± 13 years vs 27 ± 11 years, P < .0001). There was no difference in LV ejection fraction between the 3 groups. There was also no difference in MD between groups I and III (32.4 ms [26-39] vs 32 ms [26-39]). In group II, the MD in 19 patients (76%) was 56 ms (39-80). CONCLUSIONS: To the best of our knowledge, this is the first study to assess the prevalence of MD in patients with FD. MD was observed in 76% of patients with FD and LVH. The use of MD in strain echocardiography may be beneficial in the assessment of patients with FD who develop heart failure.


Assuntos
Doença de Fabry , Disfunção Ventricular Esquerda , Adulto , Ecocardiografia , Doença de Fabry/complicações , Doença de Fabry/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA