Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J. health med. sci. (Print) ; 9(3): 3-9, jul.2023. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1519661

RESUMO

ABSTRACT: The aim of this work is to provide a methodology for evaluating the committed effective dose E(50) due to the incorporation of [18F] FDG in the occupationally exposed worker (OEW) of the Cyclotron-PET/CT Laboratory of the Centro de Investigación en Ciencias Atómicas, Nucleares y Moleculares (CICANUM) at Universidad de Costa Rica using in vivo measurements. The measurement system was calibrated to perform in vivo measurements and defined as the corresponding bioassay function for the radiopharmaceutical used. The conversion factor was assessed with a known activity of 18F in the geometry and measurement time established. Among the most relevant results, the measurement parameters and the calibration procedure were defined. A value of 1.73 x 103 Bq/cps for in vivo brain measurements was obtained as a conversion factor. This study provides a methodology, to evaluate the committed effective dose due to the incorporation of 18F-FDG in a radionuclide production and diagnostic center


Assuntos
Proteção Radiológica , Exposição Ocupacional/efeitos adversos , Ciclotrons/instrumentação , Doses de Radiação
2.
J. health med. sci. (Print) ; 9(3): 17-24, jul.2023. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1523952

RESUMO

RESUMEN Durante los procedimientos intervencionistas que utilizan fluoroscopia, se entrega a los pacientes diferentes niveles de dosis de radiación, que pueden tener un impacto a corto, mediano o largo plazo, así como en su severidad. Esto en función del tipo de radiación utilizada y de la sensibilidad a la radiación del tipo(s) de órgano(s) irradiado, es en este punto que se vuelve determinante conocer la dosis a órganos entregada durante los procedimientos con el fin de asegurar el bienestar de los pacientes, este procedimiento no se puede realizar directamente en los órganos del paciente, por lo que se utilizan programas especializado en cálculos dosimétricos. El software PCXMC 2.0 logra estimar la dosis efectiva a través del método determinístico Monte Carlo, a su vez, agregando la dosis equivalente y evaluación de riesgo para estudios dosimétricos, por lo cual, el objetivo del presente trabajo fue proponer una metodología estandarizada para la utilización del programa PCXMC en el cálculo de estas dos magnitudes


ABSTRACT During interventional procedures that utilize fluoroscopy, patients are exposed to varying levels of radiation doses, which can have short, medium, or long term impacts, as well as varying severities. This depends on the type of radiation used and the radiation sensitivity of the organ(s) being irradiated. At this point, it becomes crucial to determine the organ doses delivered during procedures in order to ensure patient well-being. Since direct measurements cannot be made on the patient's organs, specialized software is used for dosimetric calculations. PCXMC 2.0 software achieves the estimation of effective dose through the deterministic Monte Carlo method, while also incorporating equivalent dose and risk assessment for dosimetric studies. Therefore, the objective of this work was to propose a standardized methodology for the use of the PCXMC 2.0 sofware in the calculation of these two magnitudes.it is important to outline a working method for this software and provide instructions on its operation


Assuntos
Doses de Radiação , Software , Fluoroscopia/métodos , Saúde Radiológica , Método de Monte Carlo , Relação Dose-Resposta à Radiação , Órgãos em Risco/efeitos da radiação
3.
Rev. méd. Urug ; 38(3): e38310, sept. 2022.
Artigo em Espanhol | LILACS, BNUY | ID: biblio-1450177

RESUMO

Introducción: la técnica de imagen híbrida de SPECT-CT combina la imagen de la tomografía por emisión de fotón único (SPECT) con el estudio de tomografía computada (TC), obteniendo información funcional y anatómica en un mismo estudio. La dosis efectiva total de radiación ionizante recibida en los estudios SPECT-CT puede ser estimada a partir de la dosis efectiva atribuible a la actividad administrada del radiofármaco y la dosis efectiva del componente de tomografía computada (TC). Objetivos: estimar la dosis efectiva total en los protocolos SPECT-CT utilizados en población adulta y determinar el aporte adicional del estudio TC sobre la dosis efectiva total. Método: se evaluaron 258 estudios SPECT-CT para estimar la dosis efectiva total aportada por la administración de los radiofármacos y los estudios de TC de baja dosis. Para estimar el aporte de ambos componentes se utilizaron factores de conversión específicos de cada radiofármaco y región explorada mediante TC. Resultados: la dosis efectiva total (media ± DS) en los estudios SPECT-CT fueron: 12,4 ± 1,44 mSv en el estudio de perfusión miocárdica, 1,14 ± 0,25 mSv en ganglio centinela de mama, 8,6 ± 0,6 mSv paratiroides, 1,48 ± 1,02 mSv tiroides y los estudios óseos de las regiones de cuello 4,5 ± 0,3, tórax 6,07 ± 0,3 mSv, abdomen y pelvis 6,1 ± 0,3 mSv. La dosis de radiación aportada por el estudio TC se encuentra entre 0,46 mSv para la región del tórax en el estudio de ganglio centinela de mama y 2,3 mSv para el SPECT-CT óseo en la región de abdomen y pelvis. Conclusión: se logró estimar la dosis efectiva en los protocolos SPECT-CT de uso clínico más frecuente en población adulta y el aporte de los estudios TC a la dosis efectiva total siendo relativamente baja comparado con la dosis aportada por los radiofármacos administrados con la excepción del estudio de ganglio centinela donde la contribución del componente TC es aproximadamente la mitad de la dosis efectiva total.


Introduction: SPECT-CT Hybrid image technique combines the SPECT (single-photon emission computed tomography) image with the CT (computerized tomography) image to obtain both functional and anatomical images in the same study. The total effective ionizing radiation dose received in SPECT-CT studies may be estimated based on the effective dose from the radiopharmaceutical administered and the effective dose from the CT (computerized tomography) component. Objectives: the study aims to estimate the total effective dose in SPECT-CT protocols applied for the adult population, and to determine the additional contribution from the CT component to the total effective dose. Method: 258 SPECT-CT studies were evaluated to estimate the total effective dose from the administration of radiopharmaceuticals and low dose CT studies. Specific conversion factors for each radiopharmaceutical and area of the body explored with the CT were used to estimate radiation doses from both components. Results: total effective dose (average ± SD) in the SPECT-CT studies was: 12.4 ± 1.44 mSv in the myocardial perfusion study, 1.14 ± 0.25 mSv in the breast sentinel lymph node study, 8.6 ± 0.6 mSv in the parathyroid study, 1.48 ± 1.02 mSv in the thyroid study. As to bone studies, doses found were: 4.5 ± 0.3, in neck studies, 6.07 ± 0.3 mSv in thoracic studies and 6.1 ± 0.3 mSv in abdominal and pelvic studies. The radiation dose from the CT study ranges from 0.46 mSv for the thoracic region on the breast sentinel lymph node study to 2.3 mSv for the bone SPECT-CT study of the abdominal and pelvic region. Conclusions: we managed to estimate the effective dose in the the most frequently used SPECT-CT protocols for the adult population and the contribution of CT studies to the total effective dose. It was found to be relatively low when compared to the dose contributed by the radiopharmaceuticals administered, with the exception of the sentinel lymph node study for which the contribution from the CT study is approximately half the total effective dose.


Introdução: a técnica de imagem híbrida SPECT-CT combina a imagem de tomografia por emissão de fóton único (SPECT) com o estudo de tomografia computadorizada (TC), obtendo informações funcionais e anatômicas no mesmo estudo. A dose efetiva total de radiação ionizante recebida em estudos SPECT-CT pode ser estimada a partir da dose efetiva atribuível à atividade administrada do radiofármaco e da dose efetiva do componente de tomografia computadorizada (TC). Objetivos: estimar a dose efetiva total nos protocolos SPECT-CT utilizados na população adulta e determinar a contribuição adicional do estudo de TC na dose efetiva total. Método : 258 estudos SPECT-CT foram avaliados para estimar a dose efetiva total fornecida pela administração de radiofármacos e estudos de TC de baixa dose. Para estimar a contribuição de ambos os componentes, foram utilizados fatores de conversão específicos para cada radiofármaco e região explorada pela TC. ⁠ Resultados: a dose efetiva total (média ± DP) nos estudos SPECT-CT foi: 12,4 ± 1,44 mSv no estudo de perfusão miocárdica, 1,14 ± 0,25 mSv no linfonodo sentinela mamário, 8,6 ± 0,6 mSv paratireoide, 1,48 ± 1,02 mSv estudos de tireoide e ossos das regiões do pescoço 4,5 ± 0,3, tórax 6,07 ± 0,3 mSv, abdômen e pelve 6,1 ±0,3mSv. A dose de radiação fornecida pelo estudo de TC está entre 0,46 mSv para a região do tórax no estudo do linfonodo sentinela da mama e 2,3 mSv para o SPECT-CT ósseo na região do abdome e pelve. Conclusão: foi possível estimar a dose efetiva nos protocolos de SPECT-CT mais utilizados clinicamente na população adulta e a contribuição dos estudos de TC para a dose efetiva total, sendo relativamente baixa em relação à dose fornecida pelos radiofármacos administrados com a exceção do estudo do linfonodo sentinela onde a contribuição do componente TC é aproximadamente metade da dose efetiva total.


Assuntos
Proteção Radiológica/normas , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/normas , Guias como Assunto , Medicina Nuclear
4.
Rev. chil. radiol ; 23(3): 130-139, 2017. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-900118

RESUMO

The objective of this study was to quantify the radiation dose reduction without impairing image quality, using 100 and 120 kiloVolts acquisition protocols. We analyzed 37 non-obese patients in a private hospital in Santiago, Chile, of which 20 were obtained with a protocol of 120 kiloVolts and the remaining 17 with low energy protocol. The quality of the image was evaluated quantitatively and qualitatively. The average image quality score for the 120 and 100 kiloVolts groups was 3.25 ± 0.8 and 3.41 ± 0.7 respectively, demonstrating an improvement in the image quality, although at a non-significant value (p= 0.58). In the images obtained with the 100 kiloVolts protocol, a reduction of 41.99% in the radiation dose was demonstrated in addition to a significant increase of the intensity of the signal and the noise. It was possible to demonstrate a decrease of the radiation dose without detriment in the diagnostic image quality in coronary angiography using computed tomography.


El objetivo de este estudio fue cuantificar la disminución de la dosis de radiación sin perjudicar la calidad de imagen, utilizando protocolos de adquisición de 100 y 120 kilovolts. Se analizaron 37 pacientes no obesos en un hospital privado de Santiago de Chile, de los cuales 20 fueron obtenidos con un protocolo de 120 kilovolts y los 17 restantes con protocolo de baja energía. Se evaluó la calidad de imagen cuantitativa y cualitativamente. El promedio de puntuación de la calidad de imagen para los grupos de 120 y 100 kilovolts fue de 3,25 ± 0,8 y 3,41 ± 0,7 respectivamente, demostrando una mejora en la calidad de imagen, aunque en un valor no significativo (p= 0,58). En las imágenes obtenidas con el protocolo de 100 kilovolts, se demostró una reducción en la dosis de radiación de un 41,99% además de un aumento significativo de la intensidad de la señal y del ruido. Se logró demostrar una disminución de la dosis de radiación sin perjuicio en la calidad de imagen diagnóstica en angiografía coronaria por tomografía computarizada.


Assuntos
Humanos , Masculino , Feminino , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA