Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 591
Filtrar
1.
Clin Implant Dent Relat Res ; 26(5): 1056-1066, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39113398

RESUMO

INTRODUCTION: The implant disease risk assessment (IDRA) tool was designed to assess an individual's risk of developing peri-implant diseases by evaluating and integrating multiple risk factors. This study aimed to evaluate the IDRA tool to determine the risk of developing peri-implant disease in patients rehabilitated with dental implants. METHODS: A retrospective observational cross-sectional study was conducted, collecting data from 92 patients with 92 selected dental implants. Data included the history of periodontitis, sites with bleeding on probing (BoP), teeth and/or implants with probing depths (PDs) ≥ 5 mm, alveolar bone loss relative to the patient's age, susceptibility to periodontitis, the frequency of supportive periodontal therapy (SPT), the distance from the restorative margin (RM) of the implant-supported prosthesis to the marginal bone crest (MBC), and factors related to the prosthesis itself. Additionally, the validated instrument periodontal risk assessment (PRA) was employed for comparison. Statistical analyses utilized Chi-square, Mann-Whitney, and ROC curve. RESULTS: Outcomes indicated that 62 implants (67.4%) were classified as high-risk. Among the IDRA parameters, history of periodontitis was the primary factor contributing to an increased risk (p < 0.001). IDRA revealed high sensitivity (100%) and low specificity (63%) (AUC = 0.685; 95% CI: 0.554-0.816; p = 0.047), and there was a low agreement between the IDRA and PRA tools (Kappa = 0.123; p = 0.014). The peri-implant disease developed in 16 implants with 5.44 (±2.50) years of follow-up, however, no significant association was observed between the high- and low-medium risk groups and the occurrence of peri-implant diseases. CONCLUSION: Most of the evaluated implants presented high IDRA risk. The IDRA tool exhibited high sensitivity and low specificity; no significant association was observed between the risk profile and the development of peri-implant diseases.


Assuntos
Implantes Dentários , Humanos , Estudos Retrospectivos , Medição de Risco , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Transversais , Implantes Dentários/efeitos adversos , Idoso , Peri-Implantite/etiologia , Adulto , Fatores de Risco , Periodontite
2.
Photodiagnosis Photodyn Ther ; 49: 104293, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39098624

RESUMO

BACKGROUND: A clinical trial was conducted to measure the effectiveness of a combined wavelength of 660 nm and 808 nm Low-Level Laser Therapy (LLLT) in reducing postoperative pain in partially and totally edentulous patients who underwent dental implant surgery. MATERIALS AND METHODS: The study included 20 blinded individuals divided in a randomized split-mouth fashion; the experimental group in one hemiarch and the control group in the other hemiarch. The experimental group received a total of 22.5 Joules (J) of LLLT divided into 5 points per implant immediately after surgery. The control group received a placebo treatment. At 24 h, 72 h, and 7 days, a blinded surveyor administered a pain questionnaire using a Numerical Rating Scale (NRS) combined with a Verbal Rating Scale (VRS) to assess pain onset after surgery, duration of the first pain episode, and pain evolution. Group data were analyzed with an ANOVA test for repeated measures and a paired t-test at defined time intervals. RESULTS: The experimental group showed a significant decrease in postoperative pain at 24 h and at 72 h for fully edentulous patients. There was a non-significant difference in the duration of the first pain episode. The mean pain levels decreased over time for both the experimental and control treatments, but only statistically significantly for the experimental group in the 24-72 h and 24 h to 7 days intervals. The same was true for the control group when comparing 24 and 72 h and between 24 h and 1 week. The time range between 72 h and 1 week showed no statistically significant differences. CONCLUSION: Within the limitations of this study, a single dose of 22.5 J LLLT per implant helps to decrease postoperative pain in dental implant surgery at 24 h for partially edentulous patients and at 24 and 72 h for fully edentulous patients.


Assuntos
Terapia com Luz de Baixa Intensidade , Dor Pós-Operatória , Humanos , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/etiologia , Terapia com Luz de Baixa Intensidade/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Medição da Dor , Adulto , Idoso , Implantes Dentários , Implantação Dentária/métodos
3.
Artigo em Inglês | MEDLINE | ID: mdl-39041319

RESUMO

OBJECTIVE: To assess the relative position of mini-implants to retain a mandibular overdenture, according to the surgical protocol, technical and anatomical factors. METHODS: Mandibular cone-beam computed tomography (CBCT) scans were analyzed for 73 patients who received four one-piece titanium-zirconium mini-implants. Drilling was performed using a 1.6 mm needle drill and a 2.2 mm Pilot Drill, according to the bone density with a surgical stent. Post-insertion CBCT images in DICOM format were analyzed using the E-Vol-DX software with BAR filters. Divergence angle between implants and between implants and the overdenture path of insertion was measured using CliniView 10.2.6 software. RESULTS: Divergence between implants ranged from 0° to 22.3° (mean = 4.2; SD = 3.7) in the lateral and from 0° to 26.2° (mean = 5.3; SD = 4.1) in the frontal projections (p < .001). Only 1 (0.2%) and 3 (0.7%) of the measurements were higher than 20° in the lateral and frontal views, respectively. The mean angulations between the implant and the path of insertion for the overdenture were 9.3° (SD = 7.5) and 4.0° (SD = 2.9) for the lateral and frontal views, respectively (p < .001). Regression analyses showed a significant association between the divergence of implants and the frontal view projection (p < .001), greater distance between the paired implants (p = .017), the flapped surgical protocol (p = .002), higher final insertion torque (p = .011), and deeper preparation with the needle drill (p < .001). CONCLUSIONS: The mini-implants were placed with low divergence angles and satisfactory parallelism. Factors including shorter distances between the implants, higher density bone, and a flapless surgical approach all contributed positively to improved parallelism of the mini-implants.

4.
J Prosthodont Res ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39019591

RESUMO

PURPOSE: This study aimed to evaluate the risk of bone loss around single short molar crown-supporting implants in an atrophic mandible. METHODS: Implants of different lengths (L = 4 or 6 mm) and diameters (Ø = 4.1 or 4.8 mm) were placed in the molar area of an atrophic mandible. Additional control mandible models were simulated for 4.1 mm diameter implants (L = 4, 6, 8, and 10 mm). A vertical masticatory load of 200 N was applied to three or six occlusal contact areas (3ca or 6ca) of the prosthetic crown. The bone strain energy density (SED) of 109.6 µJ/mm3 was assumed to be the pathological threshold for cortical bone. The peri-implant bone resorption risk index (PIBRri) was calculated by dividing the maximum SED of the crestal cortical bone by the SED pathological threshold. RESULTS: Increasing the implant length from 4 to 6 mm, implant diameter from 4.1 to 4.8 mm, and number of contact areas from 3 to 6 reduced the SED and PIBRri values by approximately 20%, 35%, and 40%, respectively, when comparing pairs of models that isolated a specific variable. All models with 6ca had a low bone resorption risk (PIBRri<0.8), while the Ø4.1 short implant with 3ca had a medium (0.8≤PIBRri≤1.0) or high (PIBRri>1.0) resorption risk. CONCLUSIONS: Increasing the diameter or occlusal contact area of a 4 mm short implant in an atrophic mandible resulted in reduced bone resorption risks, similar to or lower than those observed in a regular mandible with standard-length implants.

5.
Artigo em Inglês | MEDLINE | ID: mdl-39037121

RESUMO

BACKGROUND: The aim of this case study is to present the rationality and scientific evidence of a new design for a double (DA) and triple (TA) dental abutment-implant with their specific new concept of biodynamic optimized peri-implant tissue (BOPiT). METHODS: The innovative design of these abutments with a paraboloid geometry was based on BOPiT, simultaneously involving the principles of mechanobiology, biotensegrity, and mechanotransduction. Thus, 37 consecutive individuals/43 cases rehabilitated with single dental implant using the innovative DA (n = 28) and TA (n = 15) on 43 implants were included in this case study. The DA and TA support 2 or 3 dental crowns on a single implant, respectively. Clinic and radiographic examinations were presented at T1 (loading after 4 months) and T2 [final examination with an average follow-up time of 7.2 years (>3 to 12 years)]. RESULTS: At T2, mean scores for plaque index, peri-implant bleeding on probing, and peri-implant probing depth were low, depicting healthy peri-implant conditions. All radiographic images showed insignificant annual marginal bone loss (0.022 ± 0.05 mm) when compared to T1, reflecting great bone stability. CONCLUSION: DA and TA, based on the BOPiT concept, represent an advantageous, simple and non-invasive mechanism for the longevity and healthy regulation of the peri-implant tissues.

6.
Dent J (Basel) ; 12(7)2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39057013

RESUMO

The objective of this study was to evaluate microbial leakage by means of genome counts, through the implant-abutment interface in dental implants with different Morse taper abutments. Fifty-six samples were prepared and divided in four groups: CMC TB (14 Cylindrical Implants-14 TiBase Abutments), CMX TB (14 Conical Implants-14 TiBase Abutments), CMX PU (14 Conical Implants-14 Universal Abutment) and CMX U (14 Tapered Implants-14 UCLA Abutments). Assemblies had their interface submerged in saliva as the contaminant. Samples were subjected either to thermomechanical cycling (2 × 106 mechanical cycles with frequency of 5 Hz and load of 120 N simultaneously with thermal cycles of 5-55 °C) or thermal cycling (5-55 °C). After cycling, the contents from the inner parts of assemblies were collected and analyzed using the Checkerboard DNA-DNA hybridization technique. Significant differences in the total genome counts were found after both thermomechanical or thermal cycling: CMX U > CMX PU > CMX TB > CMC TB. There were also significant differences in individual bacterial counts in each of the groups (p < 0.05). Irrespective of mechanical cycling, the type of abutment seems to influence not only the total microbial leakage through the interface, but also seems to significantly reflect differences considering individual target species.

7.
J Dent ; 149: 105267, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39067647

RESUMO

AIM: The positive impact of implant interventions on dental patient-reported outcomes is an essential parameter of treatment effectiveness. This study assessed the 2-year changes in patient satisfaction and oral health-related quality of life (OHRQoL) of edentulous patients treated with a four mini implant mandibular overdenture (IOD) METHODS: The study was planned as a 2 × 2 factorial randomized clinical trial that tested two surgical approaches (flapped or flapless) and two loading protocols (immediate and delayed) using a titanium-zirconium mini implant (Straumann Mini Implant System®) and a PEEK retentive system (Straumann® Optiloc® Retentive System). Outcome measures (OHIP-Edent scores and the McGill Denture Satisfaction questionnaire) were assessed before treatment and at the 3-, 6-, 12-, and 24-month follow-ups. The Friedman test and multiple regression using Generalized Estimating Equations (GEE) were used for data analysis, considering the per-protocol (PP) and intention-to-treat (ITT) approaches RESULTS: Seventy-four patients were randomized to the study groups. No implant failure occurred during the study period. Marked improvement in all post-treatment periods compared to baseline were observed for the two outcomes. No significant effect of patient's gender, age, and surgical protocol on the study outcomes. The effect of treatment provision was significant for the two outcomes in the PP and ITT approaches (p < 0.001). A barely significant positive effect of the immediate loading was observed for OHIP-Edent in the PP approach (p = 0.020) CONCLUSION: IOD treatment significantly improved patient-reported outcomes measures, with sustained benefits over the two years of overdenture use, and can be considered a promising treatment option in for the edentulous mandible.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Arcada Edêntula , Mandíbula , Medidas de Resultados Relatados pelo Paciente , Satisfação do Paciente , Qualidade de Vida , Titânio , Zircônio , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Mandíbula/cirurgia , Arcada Edêntula/reabilitação , Arcada Edêntula/cirurgia , Retenção de Dentadura , Resultado do Tratamento , Prótese Total Inferior , Planejamento de Dentadura , Saúde Bucal , Carga Imediata em Implante Dentário
8.
J Dent ; 149: 105266, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39067651

RESUMO

OBJECTIVE: This 2-year prospective study reports the incidence of prosthetic complications and maintenance events after treatment with mandibular overdenture retained by four mini implants opposed to a maxillary denture. METHODS: Implant intervention included flapless or flapped surgery combined with immediate or delayed loading, as part of a randomized clinical trial. Four one-piece titanium-zirconium mini-implants (Straumann Mini Implant System) were inserted, and the retentive PEEK elements (Optiloc) were incorporated into the overdenture using chairside procedures. Prosthodontic complications and maintenance events were recorded over a 2-year follow-up, and the final outcome was defined according to standardized criteria. Data analysis included descriptive statistics, incidence and incidence density rates, and Kaplan-Meier survival. RESULTS: 73 out of 74 patients (64.9 % female), mean age of 64 (SD=8.2) years, completed the study follow-up (one withdrew after 9 months). Implant survival was 100 %. A total of 163 prosthodontic events occurred in 53 patients (72.6 %), and 20 patients had no clinical complaints or maintenance needs. The most common procedures were adjustment/repair of the overdenture base (47.0 %), replacement of retentive inserts (19.8 %), and laboratory relining (12.9 %). A high prosthodontic success rate was achieved (93.2 %), and all patients presented serviceable overdentures and continuous use after the resolution of prosthodontic complications. The incidences of matrix replacement and laboratory relines were low in the first year, while denture base adjustments were common within the first year, especially in the first 6 months. CONCLUSION: The mini implant system showed high prosthodontic success rates. Minor adjustments/repairs during the initial follow-up were common. Relines and matrix replacements tend to occur after one year of overdenture use, and matrix replacements may occur as a consequence of the need for relining.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Retenção de Dentadura , Revestimento de Dentadura , Titânio , Zircônio , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Seguimentos , Estudos Prospectivos , Retenção de Dentadura/instrumentação , Idoso , Resultado do Tratamento , Mandíbula/cirurgia , Planejamento de Dentadura , Reparação em Dentadura , Prótese Total Inferior
9.
Dent Mater ; 40(9): 1332-1340, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38876825

RESUMO

OBJECTIVES: To evaluate structural damage and loosening of abutments placed on narrow diameter implants after cyclic fatigue. METHODS: Sixty Morse taper narrow diameter implants (Neodent, Brazil) received two types of abutments (1PA- one-piece abutment or 2PA- two-piece abutment), which were randomly divided into 3 fatigue experiments (n = 10). The implants were placed into a customized supporting holder and a software-assisted digital torque wrench secured the manufacturer recommended torque for each abutment. Cone beam computed tomography (CBCT) scans were acquired, before and after fatigue, and post-processed (software e-Vol DX) to assess damage and abutment displacement. The boundary fatigue method was adapted to use 2 × 106 cycles, 2 Hz of frequency and constant peak load of 80 N (first experiment) that varied according to the failure rate of previous specimens (second and third experiments). Failure was evaluated using CBCT scans and removal torque values. Data were used to estimate long-term torque degradation, probability of failure and Weibull modulus (software ALTA PRO9). RESULTS: All 2PA specimens became loosen independently of the applied fatigue load, and structural bending was observed in 14 abutments. Eight 1PA got loosen during the fatigue experiment. The Weibull analysis showed a lower modulus (m = 1.0; 0.7, 1.4) for 1PA than for 2PA (m = 2.6; 2, 3.4) resulting in longer predicted lifetimes and slower torque degradation for 1PA than for 2PA specimens. SIGNIFICANCE: 1PA showed greater long-term survival probability than 2PA. Predicting the lifetime and mechanical behavior of implant-abutment systems are useful information to clinicians during the decision-making process of oral rehabilitations.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Dente Suporte , Projeto do Implante Dentário-Pivô , Falha de Restauração Dentária , Análise do Estresse Dentário , Torque , Implantes Dentários , Teste de Materiais
10.
J Dent ; 147: 105148, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38909648

RESUMO

OBJECTIVE: This cohort study aimed to assess the incidence of somatosensory alterations after implant surgery using standardized quantitative and qualitative sensory testing. METHODS: 33 participants with single-tooth loss, undergoing immediate implant loading were included. Quantitative Sensory Testing (QST) and Qualitative Sensory Testing (QualST) were conducted at eight time points over a year (baseline to 1 year). Two-Way Repeated Measures ANOVA and post hoc Tukey test were used on QST values and Cochran Q test on QualST. RESULTS: The study revealed significant increase in thermal thresholds overtime. At the operated side, overall Cold Pain Threshold (extraoral: p = 0.030; intraoral: p < 0.001), and Cold Detection Threshold (intraoral: p < 0.001) increased overtime. In contralateral region, maxilla Cold Detection Threshold (extraoral: p = 0.024; intraoral: p = 0.031), Warm Detection Threshold (extraoral: p = 0.026; intraoral: p = 0.047) and overall Cold Pain Threshold (extraoral and intraoral: p < 0.001) also increased. QualST showed extraoral pinprick (p = 0.032) and intraoral pinprick (p = 0.000), cold (p = 0.000) and touch (p = 0.002) stimuli abnormalities overtime. CONCLUSIONS: Somatosensory alterations after implant surgery were detected in both quantitative and qualitative sensory assessments, but rapidly decreased during the first follow-ups, and then continuously until 1-year. CLINICAL SIGNIFICANCE: This study provides clinical and controlled evidence on the real effect of the somatosensory alterations overtime, leading to a better understanding of neurosensory behaviour after single-tooth dental implant rehabilitation.


Assuntos
Implantes Dentários para Um Único Dente , Carga Imediata em Implante Dentário , Limiar da Dor , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Seguimentos , Adulto , Limiar da Dor/fisiologia , Idoso , Limiar Sensorial/fisiologia , Temperatura Baixa , Estudos de Coortes , Maxila/cirurgia , Distúrbios Somatossensoriais/etiologia
11.
J Oral Rehabil ; 51(10): 1947-1955, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38873742

RESUMO

BACKGROUND: Limited data exist on the mid- to long-term masticatory capacity of mandibular overdenture (IOD) wearers, particularly regarding the use of posterior implants to retention. OBJECTIVES: To periodically evaluate mastication of IOD wearers, comparing the effectiveness of two to four implants to retain the prosthesis. METHODS: In a randomised controlled clinical trial, 20 complete edentulous patients (14 women), aged 51-84 years (mean age 69.1 ± 9.6), received new bimaxillary complete dentures (CD). After adaptation, baseline measurements of masticatory performance (X50) and swallowing threshold were conducted using the sieving method. Patients were then randomly assigned to groups: control (two intra-foraminal regular implants) and experimental (two intra-foraminal regular implants and two extra-short posterior implants) (n = 10 each). After 4 months, implants were splinted, and a new mandibular IOD was fabricated with bar/clip retention. Mastication was reassessed after 6, 12, and 48 months, and data analysed with repeated measures ANOVA and Sidak's post hoc (α = 0.05). RESULTS: Despite a loss of two patients per group, masticatory performance significantly improved after mandibular IOD installation (p = .031) in both groups (p = .670). A second improvement was observed after 6 months (p = .027), with no subsequent changes (p > .05). Swallowing threshold improvements were noted with IOD, and no discernible differences between groups were observed (p > .05). CONCLUSION: Masticatory function significantly improved after mandibular IOD installation, with the number of implants demonstrating minimal influence. CLINICAL TRIAL REGISTRATION: The present study was not registered in a public database, as mandated. It is important to note that the recommendation for registration was initiated in 2017 by the Committee of Medical Journal Editors, while patient inclusion in the research took place in 2016. Given that the data presented in this manuscript cover a follow-up period of up to 4 years post-surgical intervention, delayed registration was not feasible.


Assuntos
Prótese Dentária Fixada por Implante , Retenção de Dentadura , Prótese Total Inferior , Revestimento de Dentadura , Mandíbula , Mastigação , Humanos , Mastigação/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Mandíbula/cirurgia , Arcada Edêntula/reabilitação , Arcada Edêntula/fisiopatologia , Implantes Dentários , Resultado do Tratamento
12.
Eur J Oral Sci ; 132(4): e12992, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38771146

RESUMO

Finite element analysis (FEA) has been used to analyze the behavior of dental materials, mainly in implantology. However, FEA is a mechanical analysis and few studies have tried to simulate the biological characteristics of the healing process of loaded implants. This study used the rule of mixtures to simulate the biological healing process of immediate implants in an alveolus socket and bone-implant junction interface through FEA. Three-dimensional geometric models of the structures were obtained, and material properties were derived from the literature. The rule of mixtures was used to simulate the healing periods-immediate and early loading, in which the concentration of each cell type, based on in vivo studies, influenced the final elastic moduli. A 100 N occlusal load was simulated in axial and oblique directions. The models were evaluated for maximum and minimum principal strains, and the bone overload was assessed through Frost's mechanostat. There was a higher strain concentration in the healing regions and cortical bone tissue near the cervical portion. The bone overload was higher in the immediate load condition. The method used in this study may help to simulate the biological healing process and could be useful to relate FEA results to clinical practice.


Assuntos
Implantes Dentários , Módulo de Elasticidade , Análise de Elementos Finitos , Carga Imediata em Implante Dentário , Alvéolo Dental , Cicatrização , Humanos , Alvéolo Dental/fisiologia , Cicatrização/fisiologia , Fenômenos Biomecânicos , Simulação por Computador , Interface Osso-Implante/fisiologia , Estresse Mecânico , Processo Alveolar/fisiologia , Modelos Biológicos , Osseointegração/fisiologia , Força de Mordida , Análise do Estresse Dentário/métodos , Osteoblastos/fisiologia , Osso Cortical/fisiologia , Imageamento Tridimensional/métodos
13.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795258

RESUMO

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Assuntos
Benzofenonas , Coroas , Dente Suporte , Análise do Estresse Dentário , Análise de Elementos Finitos , Cetonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Titânio , Zircônio , Cetonas/química , Polietilenoglicóis/química , Humanos , Zircônio/química , Titânio/química , Fibra de Carbono/química , Projeto do Implante Dentário-Pivô , Incisivo , Materiais Dentários/química , Implantes Dentários para Um Único Dente , Osso Cortical , Vidro/química , Planejamento de Prótese Dentária
14.
Clin Oral Investig ; 28(6): 315, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748313

RESUMO

OBJECTIVES: To assess whether filter and contrast adjustments can improve the accuracy of CBCT in measuring the buccal bone thickness (BBT) adjacent to dental implants by reducing blooming artifacts. MATERIALS AND METHODS: Homogeneous bone blocks with peri-implant BBT of 0.3 mm, 0.5 mm, and 1 mm were scanned using the Orthophos SL system. Three dentists measured the BBT in 234 CBCT scans under different settings of contrast adjustments and 'Sharpen' filter activation. Additionally, implant diameter measurements were taken to assess blooming artifact expression. The differences between tomographic and actual measurements of BBT and implant diameter [(CBCT - actual) * 100 / actual] were subjected to Mixed ANOVA (α = 0.05). RESULTS: The group with the thinnest BBT (0.3 mm) had the greatest difference between tomographic and actual measurements (79.9% ± 29.0%). Conversely, the 0.5 mm (36.1% ± 38.4%) and 1 mm (29.4% ± 12.3%) groups exhibited lower differences (p < 0.05). 'Sharpen' filter activation reduced blooming expression since it resulted in a lower difference for implant diameter (p < 0.05), but it did not influence BBT measurements (p = 0.673). Contrast settings had no impact on BBT (p = 0.054) or implant diameter measurements (p = 0.079). CONCLUSION: Although filter activation reduced blooming artifacts, neither filter nor contrast adjustments improved the accuracy of CBCT in measuring peri-implant BBT; actual BBT influenced this task. CLINICAL RELEVANCE: When assessing the peri-implant buccal bone plate in the CBCT system studied, dental surgeons may find it beneficial to adjust contrast and apply filters according to their preferences, since such adjustments were found to have no adverse effects on the diagnostic accuracy of this task. The use of the 'Sharpen' filter may lead to improved representation of implant dimensions.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos
15.
J Oral Rehabil ; 51(8): 1459-1467, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38685704

RESUMO

OBJECTIVE: This prospective study is part of a randomised clinical trial and reports the changes in masticatory performance (MP) and bite force, and explores their influential factors, 1 year after the provision of mandibular overdentures retained by four titanium-zirconium mini implants. METHODS: Edentulous patients received conventional complete dentures, followed by placement of four mini implants (Straumann® Mini Implant System) in the anterior mandible and converting the conventional prosthesis into a mandibular overdenture. Treatment protocols were randomised using a 2×2 factorial design combining different surgical (flapped vs. flapless) and loading (immediate vs. delayed) protocols. MP was assessed using a two-colour mixing ability test and a colorimetric analysis to measure the level of colour mixing (Variance of Hue-VoH). Maximum voluntary bite force (MBF) was measured by a digital gnathodynamometer in the posterior and anterior regions. Sex, age, surgical and loading protocols and ridge morphology were tested as independent variables. MP and MBF tests were performed at baseline (pre-treatment) and the 3-, 6- and 12-month after implant loading. Descriptive statistics, independent t-test, and linear mixed-effect model (LMM) regression were used for data analysis. RESULTS: Seventy-four participants were assessed and 73 completed the 1-year follow-up. Statistically significant improvements in functional parameters were observed in all follow-up periods compared to baseline (p < .001). The flapless protocol was associated with higher improvement in MP at the 3-month follow-up (p = .004), while less resorbed ridges were associated with better MP (p = .038) and higher MBF (p < .001). CONCLUSION: The mandibular overdenture protocol using four titanium-zirconium mini implants was effective in improving MP and MBF of edentulous patients, compared to pre-treatment values. The findings also suggest that improvements in chewing function and bite force are impacted by clinical factors since better outcomes were observed for flapless surgeries and less resorbed edentulous ridges. CLINICAL TRIAL REGISTRATION: ClinicalTrials.Gov ID NCT04760457.


Assuntos
Força de Mordida , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Mandíbula , Mastigação , Titânio , Zircônio , Humanos , Masculino , Feminino , Mastigação/fisiologia , Estudos Prospectivos , Idoso , Mandíbula/cirurgia , Pessoa de Meia-Idade , Implantes Dentários , Resultado do Tratamento , Retenção de Dentadura/métodos , Prótese Total Inferior , Arcada Edêntula/reabilitação , Arcada Edêntula/cirurgia
16.
Bioengineering (Basel) ; 11(4)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38671818

RESUMO

Peri-implantitis is an inflammatory condition characterized by inflammation in the peri-implant connective tissue and a progressive loss of supporting bone; it is commonly associated with the presence of biofilms on the surface of the implant, which is an important factor in the development and progression of the disease. The objective of this study was to evaluate, using micro-CT, the bone regeneration of surgically created peri-implant defects exposed to a microcosm of peri-implantitis. Twenty-three adult New Zealand white rabbits were included in the study. Bone defects of 7 mm diameter were created in both tibiae, and a cap-shaped titanium device was placed in the center, counter-implanted with a peri-implantitis microcosm. The bone defects received a bone substitute and/or a resorbable synthetic PLGA membrane, according to random distribution. Euthanasia was performed 15 and 30 days postoperatively. Micro-CT was performed on all samples to quantify bone regeneration parameters. Bone regeneration of critical defects occurred in all experimental groups, with a significantly greater increase in cases that received bone graft treatment (p < 0.0001), in all measured parameters, at 15 and 30 days. No significant differences were observed in the different bone neoformation parameters between the groups that did not receive bone grafts (p > 0.05). In this experimental model, the presence of peri-implantitis microcosms was not a determining factor in the bone volume parameter, both in the groups that received regenerative treatment and in those that did not.

17.
Materials (Basel) ; 17(7)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38612181

RESUMO

The use of titanium as a biomaterial for the treatment of dental implants has been successful and has become the most viable and common option. However, in the last three decades, new alternatives have emerged, such as polymers that could replace metallic materials. The aim of this research work is to demonstrate the structural effects caused by the fatigue phenomenon and the comparison with polymeric materials that may be biomechanically viable by reducing the stress shielding effect at the bone-implant interface. A numerical simulation was performed using the finite element method. Variables such as Young's modulus, Poisson's coefficient, density, yield strength, ultimate strength, and the S-N curve were included. Prior to the simulation, a representative digital model of both a dental implant and the bone was developed. A maximum load of 550 N was applied, and the analysis was considered linear, homogeneous, and isotropic. The results obtained allowed us to observe the mechanical behavior of the dental implant by means of displacements and von Mises forces. They also show the critical areas where the implant tends to fail due to fatigue. Finally, this type of non-destructive analysis proves to be versatile, avoids experimentation on people and/or animals, and reduces costs, and the iteration is unlimited in evaluating various structural parameters (geometry, materials, properties, etc.).

18.
Int J Dent Hyg ; 22(4): 825-832, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38461485

RESUMO

OBJECTIVES: Since peri-implantitis is an increasing and prevalent concern in clinical practice and there is no consensus regarding the best therapeutic protocol, this study evaluated the knowledge and behaviours of dentists working in Implantology regarding implant-related infections modulating factors and therapeutic protocols used in the management of peri-implantitis. METHODS: Cross-sectional study was conducted with 86 Brazilian Implantology clinicians. Data were collected using a structured and online questionnaire evaluating socioeconomic characteristics, education, work/clinical practice, knowledge and attitudes regarding the risk factors and management of peri-implantitis. The reliability of the questionnaire was evaluated by test-retest technique. The questionnaire was developed based on the last consensus on peri-implant diseases (2018) and the current evidence related to implant-related infections. Descriptive, bivariate and logistic regression analyses were conducted adopting a significance level of 5%. RESULTS: In this study, 89.5% of included dentists reported that already treated patients with peri-implantitis. Approximately 80% of dentists use antibiotics and mouth rinses during the treatment, and surgical procedures seem the main choice to treat peri-implantitis (91.8%) by dentists. As a preventive approach, 94.2% of dentists reported that routinely assessed biofilm accumulation in the follow-up visits after implant placement. Logistic regression showed that the self-reported ability to treat peri-implantitis was statistically (p < 0.05) higher among dentists who reported abilities to diagnose the disease and use laser for peri-implantitis treatment. CONCLUSION: Dentists working in Implantology have a good level of knowledge and behaviors in the management of peri-implantitis. However, the lack of consensus regarding the best treatment protocols may reflect dentist's behaviours because different treatment protocols have been used by evaluated clinicians.


Assuntos
Odontólogos , Conhecimentos, Atitudes e Prática em Saúde , Peri-Implantite , Humanos , Peri-Implantite/terapia , Estudos Transversais , Masculino , Feminino , Inquéritos e Questionários , Brasil , Adulto , Odontólogos/psicologia , Padrões de Prática Odontológica/estatística & dados numéricos , Pessoa de Meia-Idade , Antibacterianos/uso terapêutico , Fatores de Risco , Atitude do Pessoal de Saúde , Implantes Dentários , Biofilmes
19.
Dentomaxillofac Radiol ; 53(4): 233-239, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38466923

RESUMO

OBJECTIVES: This study evaluated the effect of metal artefact reduction (MAR) level and tube current on the assessment of dental implant positioning relative to the mandibular canal (MC) through cone-beam computed tomography (CBCT). METHODS: Titanium dental implants were placed in dried mandibles at 0.5-mm superior to the MC (group 1/n = 8) and 0.5-mm inside the MC with perforation of the cortex (group 2/n = 10). CBCT scans were obtained with different levels of MAR (off, medium, and high) and 2 tube currents (4 and 8 mA). Four examiners analysed the images and scored the contact between the implant and the MC using a 5-point scale. Sensitivity, specificity, area under receiver operating characteristic curve (ROC), and frequency of scores were calculated. Data were compared with analysis of variance 2-way and Tukey's test and scores with Chi-square test. RESULTS: Specificity and area under ROC curve decreased significantly when MAR level was high compared with MAR-medium and MAR-off. The frequency of score 3 (inconclusive) was the highest, and scores 1 and 5 (definitely no contact and definitely contact, respectively) were the lowest with MAR-high, regardless of the tube current. When MAR was off, there were higher frequencies of scores 1 and 5. CONCLUSIONS: The level of MAR influences the assessment of the relationship between the dental implant and the MC. MAR-high led to lower diagnostic accuracy compared with MAR-medium and off. ADVANCES IN KNOWLEDGE: This article shows that high level of MAR can interfere in the diagnostic of dental implant positioning relative to the MC, decreasing its accuracy.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Mandíbula/diagnóstico por imagem , Titânio , Sensibilidade e Especificidade , Metais , Técnicas In Vitro
20.
Saudi Dent J ; 36(1): 20-27, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38375384

RESUMO

Background: Focal osteoporotic bone marrow defect (FOBMD) is a rare and poorly documented pathology corresponding to an unusual hematopoietic tissue in maxillary bones. Several studies have investigated FOBMD but reported different and heterogenous approaches to a correct diagnosis. Therefore, this systematic review evaluated the relevance of imaging exams in aiding FOBMD diagnosis and the implications in surgical planning for dental implants.The research question was: What is the relevance of imaging tests in aiding FOBMD diagnosis? Methods: Online databases were searched to select articles based on eligibility criteria. The studies included in the systematic review were submitted to bias and applicability assessments using the Joanna Briggs Institute tool for study quality assessment. Results: A total of 383 articles were obtained from all the databases, 27 studies were included, and all performed biopsies to confirm the diagnosis. The selected studies evaluated 698 patients, including approximately 80% of women, corroborating the literature that notes a higher prevalence of this lesion in women. The reviewed articles showed a low risk of bias for case series, moderate for case reports, and low for cross-sectional studies. Conclusion: The studies considered in this systematic review have shown that radiographic characteristics may sufficiently identify the lesion and provide a periodic radiographic follow-up. However, it is worth noting the need for CBCT for planning oral rehabilitation through implants to minimize the risks of such complications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA