RESUMO
Abstract Sudden cardiac death is a common occurrence. Out-of-hospital cardiac arrest is a global public health problem suffered by ≈3.8 million people annually. Progress has been made in the knowledge of this disease, its prevention, and treatment; however, most events occur in people without a previous diagnosis of heart disease. Due to its multifactorial and complex nature, it represents a challenge in public health, so it led us to work in a consensus to achieve the implementation of cardioprotected areas in Mexico as a priority mechanism to treat these events. Public access cardiopulmonary resuscitation (CPR) and early defibrillation require training of non-medical personnel, who are usually the first responders in the chain of survival. They should be able to establish a basic and efficient CPR and use of the automatic external defibrillator (AED) until the emergency services arrive at the scene of the incident. Some of the current problems in Mexico and alternative solutions for them are addressed in the present work.
Resumen La muerte súbita cardíaca (SCD) es un acontecimiento común. El paro cardiaco extrahospitalario (OHCA) es un problema de salud pública mundial que sufren ≈3.8 millones de personas al año. Se ha avanzado en el conocimiento de esta enfermedad, su prevención y tratamiento, sin embargo, la mayoría de los eventos se producen en personas sin diagnóstico previo de cardiopatía. Debido a su carácter multifactorial y complejo, representa un reto en salud pública, lo que obliga a trabajar en un consenso para lograr la implementación de "Espacios Cardio protegidos" en México, como mecanismo prioritario de atención a estos eventos. La reanimación cardiopulmonar básica (RCPB) y la desfibrilación temprana de acceso público requieren de entrenamiento al personal no médico, que suelen ser los primeros respondientes para iniciar la cadena de la supervivencia. Ellos deberían instaurar una RCPB eficiente y el uso del desfibrilador automático externo (AED) hasta que lleguen al lugar del incidente los servicios de emergencias. El presente trabajo menciona algunos de los problemas actuales en México y algunas opciones de solución para los mismos.
RESUMO
OBJETIVO: Conocer el nivel de preparación de colegios y profesores de educación física en prevención de muerte súbita (MS) y soporte vital básico, incluyendo disponibilidad y uso del desfibrilador externo automático (DEA). MÉTODOS: Estudio descriptivo de corte transversal, en profesores de educación física de establecimientos educacionales de distintos tipos de sostenedores (municipales, subvencionados y particulares) de Santiago, Chile, a través de un cuestionario online. Se analizaron datos demográficos del profesor, antecedentes de preparación y disposición de reanimación cardiopulmonar (RCP), presencia y uso de DEA y preparación del establecimiento ante un caso de MS. RESULTADOS: De 97 profesores encuestados, 71,1% no se siente capacitado para realizar RCP a pesar que un 70% del total ha realizado un curso. La disposición para realizar reanimación en aquellos que han realizado un curso, es 99%, comparado con 83% en quienes no lo han realizado (p=0,003). Existe una marcada diferencia en disponibilidad de DEA según tipo de sostenedor (52,4% en particulares, 29,6% en municipales y 15% en subvencionados, p=0,001), pero transversalmente no saben cómo utilizarlo (42,9 %, 40,7% y 25%, p=0,43). La mayoría de los colegios no cuenta con un plan de acción ante MS. CONCLUSIONES: Los colegios y profesores de educación física tienen una preparación insuficiente y desactualizada en prevención de muerte súbita y soporte vital básico, con una distribución heterogénea de DEA en establecimiento según tipo de sostenedor.
OBJECTIVE: To assess the competence of schools and physical education teachers in the prevention of sudden death (SD) and basic life support meassures, including availability and use of the automatic external defibrillator (AED). METHODS: A descriptive cross-sectional study included physical education teachers from different Schools (public, subsidized and private) in Santiago, Chile. An online questionnaire was applied including demographic data of the teacher, comentence and willingness to perform cardiopulmonary resuscitation (CPR), presence and use of AED and school preparation in case of a SD. RESULTS: From a total of 97 teachers surveyed do not feel capable of performing CPR, in spite of the fact that 70% of them completed a CPR course. Among those who took a course, their willingness to perform resuscitation was 99%, compared to 83% en those not having taken the course (p = 0.003). There was a marked difference in DEA availability according to class of school (private 52,4%, public 29,6 subsidized 15%, p=0,001), but the knowledge on how to use de DEA was uniformly insufficient (42,9 %, 40,7% and 25%, p=0,43) Most schools do not have a protocol to face SD. CONCLUSIONS: We observed that schools and physical education teachers have an insufficient and outdated preparation in sudden death prevention and basic life support. The availability of AED differed according to the class of establishment.
Assuntos
Humanos , Masculino , Feminino , Adulto , Educação Física e Treinamento , Reanimação Cardiopulmonar/educação , Conhecimento , Morte Súbita/prevenção & controle , Professores Escolares/psicologia , Chile , Estudos Transversais , Inquéritos e Questionários , DesfibriladoresRESUMO
Resumen Introducción: son pocos los datos documentados sobre los resultados de la reanimación cardiopulmonar en el paro cardiorrespiratorio extrahospitalario por causa de electrocución. El paro cardiorrespiratorio se produce cuando una descarga eléctrica interrumpe de forma abrupta la actividad eléctrica normal del corazón, lo que genera una electrocución y una alteración en los movimientos cardiacos y, por consiguiente, bombeo anormal de sangre y oxígeno a los tejidos. Ello constituye una emergencia clínica que puede ocasionar nefastas consecuencias de no tomarse medidas enérgicas e inmediatas. Presentación del caso: hombre con paro cardiorrespiratorio producido por electrocución y manejado en un ámbito extra-hospitalario, quien respondió con éxito a las maniobras aplicadas. Personal técnico y de salud iniciaron precozmente la reanimación cardiopulmonar y luego fue reforzada por personal médico, que aplicó desflbrilación en dos ocasiones con desflbrilador externo automático (DEA). Con ello se logró recuperar los signos vitales del paciente y trasladarlo a un centro asistencial para continuar su manejo intrahospitalario. Conclusión: la realización de una reanimación precoz y la desfibrilación de pacientes electrocutados, así como las medidas encaminadas a la protección del cerebro, son la norma prioritaria en la asistencia pre-hospitalaria de estos pacientes, quienes son potencialmente recuperables. Por tal razón, es importante que la comunidad, en general, esté preparada y que el personal de salud se reentrene en soporte vital básico, que incluye el manejo del DEA para dar oportunidad de sobrevivir a personas que sufran un paro cardiorrespiratorio extrahospitalario.
Abstract Introduction: There are few the documented data about the cardiopulmonary resuscitation results in the cardiorespiratory arrest extra-hospital due to the electrocution. The cardiorespiratory arrest occurs when the heart's normal electrical activity is abruptly interrupted by electric shocks generated by electrocution, causing the disturbance in the cardiac movements and, consequently, abnormal pumping of blood and oxygen to the tissues. The cardiorespiratory arrest due to electrocution is one clinic emergency that can cause disastrous consequences, if energetic measures are not taken immediately. Case presentation: A man with cardiorespiratory arrest produced by electrocution and managed in an extra-hospital area, who responded successfully to the maneuvers applied. The cardiopulmonary resus-citation maneuvers were precociously started by the health technical staff; next, reinforced by medical it, applying the defibrillation on two occasions, with external automatic defibrillator (AED), recovering the patient's vital signs and allowing his transfer to a healthcare center to continue in-hospital management. Conclusion: The performing of early resuscitation and defibrillation of electrocuted patients, as well as the measures aimed at protecting the brain, are the priority rules in the pre-hospital scene of these patients, who are potentially recoverable. For this reason, it is important that the community, in general, be ready, and the health staff gets trained in basic vital support that includes the management of AED to give the opportunity of surviving to people that suffer a cardiorespiratory arrest.
Resumo Introdução: são poucos os dados documentados sobre os resultados da reanimação cardiopulmonar na parada cardiorrespiratória extra-hospitalar por causa de eletrocussão. A parada cardiorrespiratória se produz quando a atividade elétrica normal do coração é interrompida abruptamente pela descarga elétrica que gera a eletrocussão causando alterado nos movimentos cardíacos e por conseguinte bombeamento anormal de sangue e oxigeno aos tecidos. A parada cardiorrespiratória causada por eletrocussão é uma emergência clínica que pode ocasionar nefastas consequências, de não tomar medidas enérgicas e imediatas. Apresentação do caso: homem com parada cardiorrespiratória, produzida por eletrocussão e manejado em um âmbito extra-hospitalar, quem respondeu com sucesso ás manobras aplicadas. A rearrumação cardiopulmonar foi iniciada precocemente por pessoal técnico de saúde, posteriormente reforjadas por pessoal médico, aplicando a desfibrilação em duas ocasiões, com desfibrilador automático externo (DEA), recuperando os signos vitais do paciente e permitindo seu traslado e um centro assistencial para continuar manejo intra-hospitalar. Conclusão: a realizado de uma rearrumação precoce e desfibrilação de pacientes eletrocutados, assim como as medidas encaminhadas á proteção do cérebro, são a norma prioritária na assistência pré-hospitalar destes pacientes, os quais são potencialmente recuperáveis; por esta razão é importante que a comunidade, em geral, esteja preparada e que o pessoal de saúde se retreine em suporte vital básico que inclua o manejo do DEA para dar oportunidade de sobrevida a pessoas que sofram uma parada cardiorrespiratória extra-hospitalar.
Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Parada Cardíaca , Reanimação Cardiopulmonar , Traumatismos por Eletricidade , Parada Cardíaca Extra-HospitalarRESUMO
OBJETIVOS: Avaliar a eficácia da desfibrilação em resposta à fibrilação ventricular induzida e descrever as mudanças macroscópicas ocorridas nos corações de suínos após choque de descarga capacitiva exponencial truncada aplicado por protótipo de desfibrilador produzido no Brasil e por um desfibrilador de referência, líder de mercado internacional.MÉTODOS: Dezesseis suínos foram agrupados em quatro grupos de quatro animais, para verificar a eficácia da desfibrilação em resposta à fibrilação ventricular induzida, aplicando cargas de 50 J e 100 J, assim como avaliar a segurança dos desfibriladores usados, através de análises macroscópicas da pele e do coração. Foram avaliados eritema, edema, bolhas, líquido na cavidade pericárdica, queimaduras e tecido carbonizado pós-choque.RESULTADOS: Todos os suínos, após um minuto da indução à fibrilação ventricular, desenvolveram taquicardia que progrediu à fibrilação ventricular. Quando utilizada baixa energia, o equipamento protótipo obteve 25% de sucesso com um suíno revertido, enquanto o equipamento referência obteve 50% de sucesso, com duas reversões. Entretanto, com energia a 100 J, o equipamento protótipo reestabeleceu o ritmo sinusal em três suínos (75%) e o equipamento referência realizou somente uma desfibrilação eficaz (25%). A aplicação de energia 100 J associou-se com queimadura cutânea de Grau II em apenas um suíno com o desfibrilador protótipo e em quatro suínos com o equipamento referência. As lesões do tecido cardíaco ocorreram em igual número com ambos os desfibriladores.CONCLUSÕES: O desfibrilador protótipo, quando aplicado com energia 100 J, demonstrou maior eficácia na reversão da fibrilação ventricular e apresentou menor injúria que o desfibrilador de referência com a mesma energia. Este estudo ajudará a elevar o padrão tecnológico e a ampliar a oferta qualificada de equipamentos para a saúde produzidos no Brasil, substituindo e/ou diminuindo importações e oferecendo um dispositivo seguro de última geração.
AIMS: To evaluate the efficacy of defibrillation in response to induced ventricular fibrillation and to describe the macroscopic changes in porcine hearts after truncated exponential capacitive discharge shock applied by a prototype defibrillator produced in Brazil and a reference, international market leader defibrillator.METHODS: Sixteen pigs were divided into four groups of four animals each, to verify the effectiveness of the defibrillator in response to induced ventricular fibrillation by applying loads of 50 J to 100 J, and assess the safety of the defibrillator by macroscopic analysis of the skin and heart. Erythema, edema, blistering, fluid in the pericardial cavity, burns, and post-shock charred tissue were evaluated.RESULTS: All pigs, after one minute of inducing ventricular fibrillation, developed tachycardia and progressed to ventricular fibrillation. When used low energy, the prototype equipment obtained 25% of success, with one reversed pig, while the reference equipment has obtained a success rate of 50%, with two reversals. However, with energy 100 J, the prototype equipment reestablished sinus rhythm in three pigs (75%) and the reference product only made effective defibrillation in one (25%). The application of 100 J energy was associated with skin burns Grade II in only one pig with the prototype defibrillator and four pigs with the reference equipment. The heart tissue injuries occurred in equal numbers with both defibrillators.CONCLUSIONS: The prototype defibrillator, when applied with 100 J energy, was more effective in reversing ventricular fibrillation and showed less injury than the reference defibrillator with the same energy. This study may help to raise the technological standard and to increase the supply of qualified health equipment produced in Brazil, replacing and/or decreasing imports and providing a secure next-generation device.