RESUMO
OBJECTIVE: To evaluate the feasibility and accuracy of an unprecedented COVID-19 antigen testing program in schools, which required a healthcare provider order, laboratory director, a Clinical Laboratory Improvement Amendments certificate of waiver, as well as training of school personnel. STUDY DESIGN: Descriptive report of a point-of-care, school-based antigen testing program in California from August 1st, 2021 through May 30, 2022, in which participants grades K-12 self-swabbed and school personnel performed testing. Participants included 944 009 students, personnel, and community members from 4022 California kindergarten through high schools. Outcomes measured include sensitivity and specificity (with polymerase chain reaction [PCR] as comparator) of the Abbott BinaxNOW antigen test, number of tests performed, and active infections identified. RESULTS: Of 102 022 paired PCR/antigen tests, the overall sensitivity and specificity for the antigen test was 81.2% (95% CI: 80.5%-81.8%) and 99.6% (95% CI: 99.5%-99.6%), respectively, using cycle threshold values <30. During January through March 2022, the highest prevalence period, the positive predictive value of antigen testing was 94.7% and the negative predictive value was 94.2%. Overall, 4022 school sites were enrolled and 3 987 840 million antigen tests were performed on 944 009 individuals. A total of 162 927 positive antigen tests were reported in 135 163 individuals (14.3% of persons tested). CONCLUSIONS: Rapidly implementing a school-based testing program in thousands of schools is feasible. Self-swabbing and testing by school personnel can yield accurate results. On-site COVID-19 testing is no longer necessary in schools, but this model provides a framework for future infectious disease threats.
Assuntos
COVID-19 , Testes Imediatos , Sensibilidade e Especificidade , Humanos , COVID-19/diagnóstico , COVID-19/epidemiologia , California , Criança , Adolescente , Instituições Acadêmicas , Feminino , Masculino , Teste para COVID-19/métodos , Teste Sorológico para COVID-19/métodos , Serviços de Saúde Escolar , SARS-CoV-2 , Estudos de ViabilidadeRESUMO
Until recently, the incidence of COVID-19 was primarily estimated using molecular diagnostic methods. However, the number of cases is vastly underreported using these methods. Seroprevalence studies estimate cumulative infection incidences and allow monitoring of transmission dynamics, and the presence of neutralizing antibodies in the population. In February 2020, the Mexican Social Security Institute began conducting anonymous unrelated sampling of residual sera from specimens across the country, excluding patients with fever within the previous two weeks and/or patients with an acute respiratory infection. Sampling was carried out weekly and began 17 days before Mexico's first officially confirmed case. The 24,273 sera obtained were analyzed by chemiluminescent-linked immunosorbent assay (CLIA) IgG S1/S2 and, later, positive cases using this technique were also analyzed to determine the rate of neutralization using the enzyme-linked immunosorbent assay (ELISA). We identified 40 CLIA IgG positive cases before the first official report of SARS-CoV-2 infection in Mexico. The national seroprevalence was 3.5% in February and 33.5% in December. Neutralizing activity among IgG positives patients during overall study period was 86.1%. The extent of the SARS-CoV-2 infection in Mexico is 21 times higher than that reported by molecular techniques. Although the general population is still far from achieving herd immunity, epidemiological indicators should be re-estimated based on serological studies of this type.
RESUMO
The new coronavirus that was first identified in December 2019 in Wuhan China, now called SARS-CoV-2, which causes the disease called COVID-19, has spread from China to the entire world in a few months. Due to its contagious potential (R0: 5.7) and because there is still no effective treatment to stop the infection, and a vaccine for prevention it is not yet available to the general population, COVID-19 is currently considered a global health problem. The need to implement sensitive methods for the identification of individuals with COVID-19 has led to the development of different molecular and immunological tests. The importance of a timely and accurate diagnosis is essential to determine the course of the pandemic. The interpretation of the results obtained by each test as well as the factors that affect these results have not been fully described. In this review, we describe and analyze the different SARS-CoV-2 detection methods that have been performed in Mexico and are available worldwide, outlining their strengths and weaknesses. Further, a broader perspective of the correct use and interpretation of the results obtained with these diagnostic tools is proposed to improve the containment strategy and identify the true impact of the pandemic.
RESUMO
The glutathione S-transferase (GST)-L1 multiplex serology assay has favorable properties for use in clinical trials and epidemiologic studies, including low cost, high throughput capacity, and low serum volume requirement. Therefore, we evaluated the GST-L1 assay as a measure of HPV16/18 vaccine immunogenicity. Our study population included 65 women selected from the Costa Rica Vaccine Trial who received the bivalent HPV16/18 virus-like particle (VLP) vaccine at the recommended 0/1/6-month schedule. We tested replicate serum samples from months 0/1/12 (i.e., after 0/1/3 doses) by GST-L1 and 3 other commonly used serology assays, VLP-ELISA, SEAP-NA, and cLIA. We calculated the percentage of women seropositive by GST-L1 by time point and HPV type (14 HPV types), and compared GST-L1 to other assays using Spearman rank correlation coefficients. After 1 vaccine dose, seropositivity by GST-L1 was 40% each for HPV16 and HPV18, increasing to 100% and 98%, respectively, after 3 doses. Seropositivity after 3 doses ranged from 32% to 69% for HPV types 31/33/45, for which partial vaccine efficacy is reported, though increases also occurred for types with no evidence for cross-protection (e.g., HPV77). GST-L1 correlated best after 3 doses with VLP-ELISA (HPV16 and HPV18 each ρ = 0.72) and SEAP-NA (HPV16 ρ = 0.65, HPV18 ρ = 0.71) (all P < 0.001); correlation was lower with cLIA. The GST-L1 is suitable for evaluating HPV16/18 vaccine immunogenicity after 3 vaccine doses, although in contrast to other assays it may classify some samples as HPV16/18 seronegative. The assay's utility is limited for lower antibody levels such as after receipt of 1 dose.
Assuntos
Bioensaio/métodos , Papillomavirus Humano 16/imunologia , Papillomavirus Humano 18/imunologia , Infecções por Papillomavirus/imunologia , Vacinas contra Papillomavirus/imunologia , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Formação de Anticorpos/imunologia , Costa Rica , Proteção Cruzada , Feminino , Glutationa Transferase/metabolismo , Humanos , Imunização Secundária , Infecções por Papillomavirus/prevenção & controle , Reprodutibilidade dos Testes , VacinaçãoRESUMO
Una de las más importantes pero la menos común de las manifestaciones de enfermedad autoinmune la constituye la vasculitis, la cual modifica la historia de la enfermedad, dependiendo del órgano afectado. Esta revisión incluye las más importantes manifestaciones y complicaciones de los sistemas nerviosos central y periférico que se desarrollan por vasculitis en las enfermedades reumáticas, ya sea como una primera manifestación de enfermedad o como acompañante de enfermedad sistémica. También hacemos una revisión de la inmunopatogénesis, los principales hallazgos radiológicos, hallazgos en las biopsias de tejido cerebral o de nervio periférico, en las biopsias de músculo, con los posibles diagnósticos diferenciales conocidos.
The vasculitis is one of the most common manifestations of autoimmune diseases, it will change the medical evolution depending on the affected organ. This review includes the most important manifestations and complications in the central and peripheral nervous system, due to vasculitis developed in the setting of rheumatic diseases, as a primary manifestation or as a part of other symptoms, as well. Also, an up date in immunopathogenesis, radiology, peripheral and central nervous biopsy, muscle biopsy findings, and differential diagnosis is made.