Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 354
Filtrar
1.
Ciênc. rural (Online) ; 54(2): e20220612, 2024. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1505986

RESUMO

The effect of ultrasound on Biceps femoris muscle tenderness was investigated using a 22 Central Composite Rotatable Design (CCRD) with triplicates at the central point. We evaluated the following independent variables: ultrasound intensity ranging from 11.30 to 33.90 W cm-2 and exposure time between 35 and 205 s. The ultrasound bath's frequency (80 kHz) and temperature (10 ºC) were the fixed ones. To validate the model, the muscle was treated at the CCRD's optimized condition (80 kHz, 22.60 W cm-2, 120 s, 10 ºC) evaluated, and compared with the muscle control sample (non-treated). A 22% shear force reduction was observed compared to the control sample (no ultrasound treatment) after 144 h, and stored at 5 ºC. Moreover, a sarcoplasmic calcium concentration increase was noted for ultrasound-treated muscle, probably activating the calpain enzyme system. In contrast, no significant influence (P > 0.05) was observed for pH, color index, lipid oxidation, water holding capacity, and drip loss by ultrasound treatment at the optimized conditions. Therefore, ultrasound application is promising and suitable for improving muscle tenderness without losing meat quality. This study highlighted the ultrasound effect on the tenderness of a less studied muscle (Biceps femoris) by combining short ultrasound exposure (120 s) and an 80 kHz frequency.


O efeito do ultrassom sob a maciez do músculo Biceps femoris foi avaliado usando um Delineamento Composto Central Rotacional (DCCR) 22 com triplicatas no ponto central. As variáveis independentes estudadas foram a intensidade do ultrassom que variou de 11,30 a 33,90 W cm-2 e o tempo de exposição de 35 e 205 s. A frequência do banho de ultrassom (80 kHz) e a temperatura (10 ºC) foram fixas. Para validar o modelo, a carne foi tratada na condição otimizada do DCCR (80 kHz, 22,60 W cm-2, 120 s, 10 ºC), avaliada e comparada à amostra controle (não tratada). Uma redução de 22% na força de cisalhamento foi observada em comparação à amostra controle após 144 h e armazenada a 5 ºC. Além disso, um aumento da concentração de cálcio sarcoplasmático foi observado para o músculo tratado com ultrassom, o que provavelmente ativou o sistema enzimático da calpaína. Em contraste, o tratamento com ultrassom nas condições otimizadas não influenciou significativamente (P > 0,05) o pH, cor, oxidação lipídica, capacidade de retenção de água e perda de gotejamento. Portanto, a aplicação do ultrassom é promissora e adequada para melhorar a maciez do músculo sem perder a qualidade da carne. Este estudo destacou o efeito do ultrassom na maciez de um músculo pouco estudado (Biceps femoris) ao combinar exposição curta ao ultrassom (120 s) e uma frequência de 80 kHz.


Assuntos
Animais , Bovinos , Ultrassom , Músculos Isquiossurais , Carne
2.
Braz. dent. sci ; 27(2): 1-10, 2024. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1563105

RESUMO

Objective: To evaluate the effect of saliva contamination and different decontamination protocols on the microshear bond strength of a universal adhesive to dentin. Material and Methods: 84 bovine teeth were divided into three groups according to bonding stage at which salivary contamination occurred; before curing of the adhesive, after curing of the adhesive, and a control group with no salivary contamination. Each group was further subdivided into four subgroups according to the decontamination protocol used (n=7): no decontamination protocol, rinsing then reapplication of the adhesive, grinding with sandpaper silicon carbide grit 600 then reapplication of the adhesive and finally ethanol application then reapplication of the adhesive. Specimens were tested in micro-shear mode. Results: All the decontamination protocols used in this study to reverse effect of salivary contamination before curing significantly improved the bond strength to contaminated dentin (p<0.001). Meanwhile, after curing, ethanol decontamination protocol recorded highest bond strength followed by rinsing and grinding compared to no decontamination (p<0.001). Conclusion: Saliva contamination led to significant deterioration in the bond strength regardless of the bonding stage at which saliva contamination occurred. All decontamination protocols improved the immediate microshear bond strength when contamination occurred before curing of the adhesive, while ethanol seemed to be the most effective both before curing and after curing (AU)


Objetivo: Avaliar o efeito da contaminação por saliva e de diferentes protocolos de descontaminação na resistência de união ao microcisalhamento de um adesivo universal à dentina. Material e Métodos: 84 dentes bovinos foram divididos em três grupos de acordo com o passo operatório do protocolo adesivo em que ocorreu a contaminação por saliva: antes da polimerização do adesivo, ou após a polimerização do adesivo e um grupo controle sem contaminação por saliva. Cada grupo foi subdividido em quatro subgrupos de acordo com o protocolo de descontaminação utilizado (n=7): sem protocolo de descontaminação; lavagem seguida da reaplicação do adesivo; lixar a região com lixa de carbeto de silício de granulação 600 e reaplicar o adesivo; aplicar etanol e reaplicar o adesivo. Os espécimes foram testados no modo de micro-cisalhamento. Resultados: Todos os protocolos de descontaminação utilizados neste estudo em busca de reverter o efeito da contaminação do adesivo por saliva melhoraram significativamente a resistência de união à dentina contaminada (p<0,001). Enquanto isso, após a polimerização, o protocolo de descontaminação com etanol resultou na maior resistência de união, seguido pela lavagem, e depois pelo lixamento, em comparação com nenhum protocolo de descontaminação (p<0,001). Conclusão: A contaminação por saliva levou a uma deterioração significativa na resistência de união, independentemente do passo operatório do protocolo adesivo em que ocorreu a contaminação por saliva. Todos os protocolos de descontaminação melhoraram a resistência de união ao microcisalhamento imediato quando a contaminação ocorreu antes da polimerização do adesivo, enquanto o etanol pareceu ser o protocolo mais eficaz nos dois tipos de contaminação (antes e depois da polimerização).


Assuntos
Saliva , Descontaminação , Adesivos Dentinários , Resistência ao Cisalhamento , Etanol
3.
Rev. Urug. med. Interna ; 8(3)dic. 2023.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1521629

RESUMO

Introducción: Las hepatopatías son un problema prevalente a nivel mundial. La biopsia hepática ha sido hasta la fecha el gold standard para valorar el grado de fibrosis, sin embargo, con el advenimiento de nuevos métodos no invasivos, costo-efectivos para el sistema sanitario, cada vez recurrimos menos a esta. En nuestro medio se introdujo recientemente la elastografía por onda cizallamiento con imagen biplanar, lo que implica una curva de aprendizaje por parte de los técnicos. Objetivo: Valorar la asociación de los grados de fibrosis hepática determinado por la elastografía por onda de cizallamiento con imagen biplanar (2D-SWE) y el score APRI en pacientes portadores de enfermedad hepática asistidos en el servicio de hepatología del Hospital Pasteur.Médica 2. Metodología: Se incluyeron los pacientes con enfermedad hepática de cualquier etiología, asistidos entre el 01/10/21 al 31/08/22, mayores de 15 años, de ambos sexos y que han sido valorados con elastografía por onda de cizallamiento con imagen biplanar (2D-SWE) y analítica sanguínea realizado por el equipo médico del servicio mencionado en los últimos 6 meses. Resultados: Se incluyeron 158 pacientes. Se encontró mayor prevalencia de enfermedad hepática en mujeres, con predominio de la etiología de enfermedad por hígado graso no alcohólico (EHGNA) e infección por virus de hepatitis C (VHC). Se evidenció asociación positiva entre la elastografía (2D-SWE) y el score APRI para el diagnóstico o exclusión de enfermedad hepática avanzada, sin diferencia estadísticamente significativa entre los dos médicos hepatólogos. Conclusiones: Existe asociación entre la elastografía por SWE y el score APRI para el diagnóstico de enfermedad hepática avanzada en la población general y por etiología.


Introduction: Liver diseases are a prevalent problem worldwide. To date, liver biopsy has been the gold standard for assessing the degree of fibrosis; however, with the advent of new non-invasive, cost-effective methods for the healthcare system, we are resorting to it less and less. Shear wave elastography with biplanar imaging was recently introduced in our setting, which implies a learning curve for technicians. Objective: To assess the association of the degrees of liver fibrosis determined by shear wave elastography with biplanar imaging (2D-SWE) and the APRI score in patients with liver disease treated in the hepatology service of the Pasteur Hospital. Methodology: Patients with liver disease of any etiology, attended between 01/10/21 and 08/31/22, over 15 years of age, of both sexes and who have been evaluated with shear wave elastography with biplanar image were included. (2D-SWE) and blood analysis performed by the medical team of the aforementioned service in the last 6 months. Results: 158 patients were included. A higher prevalence of liver disease was found in women, with a predominance of the etiology of nonalcoholic fatty liver disease (NAFLD) and hepatitis C virus (HCV) infection. A positive association was evident between elastography (2D-SWE) and the APRI score for the diagnosis or exclusion of advanced liver disease, with no statistically significant difference between the two hepatologists. Conclusions: There is an association between SWE elastography and the APRI score for the diagnosis of advanced liver disease in the general population and by etiology.


Introdução: As doenças hepáticas são um problema prevalente em todo o mundo. Até o momento, a biópsia hepática tem sido o padrão ouro para avaliar o grau de fibrose, porém, com o advento de novos métodos não invasivos e de baixo custo para o sistema de saúde, recorremos cada vez menos a ela. A elastografia por onda de cisalhamento com imagem biplanar foi introduzida recentemente em nosso meio, o que implica uma curva de aprendizado para os técnicos. Objetivo: Avaliar a associação dos graus de fibrose hepática determinados pela elastografia por ondas de cisalhamento com imagem biplanar (2D-SWE) e o escore APRI em pacientes com hepatopatia atendidos no serviço de hepatologia do Hospital Pasteur. Metodologia: Foram incluídos pacientes portadores de doença hepática de qualquer etiologia, atendidos entre 10/01/21 e 31/08/22, maiores de 15 anos, de ambos os sexos e que foram avaliados com elastografia por onda de cisalhamento com imagem biplanar. ( 2D-SWE) e análises sanguíneas realizadas pela equipa médica do referido serviço nos últimos 6 meses. Resultados: foram incluídos 158 pacientes. Foi encontrada maior prevalência de doença hepática em mulheres, com predomínio da etiologia da doença hepática gordurosa não alcoólica (DHGNA) e da infecção pelo vírus da hepatite C (HCV). Foi evidente uma associação positiva entre a elastografia (2D-SWE) e o escore APRI para o diagnóstico ou exclusão de doença hepática avançada, sem diferença estatisticamente significativa entre os dois hepatologistas. Conclusões: Existe associação entre a elastografia SWE e o escore APRI para o diagnóstico de doença hepática avançada na população geral e por etiologia.

4.
Semina ciênc. agrar ; 44(4): 1429-1440, set. 2023. tab
Artigo em Inglês | VETINDEX | ID: biblio-1512046

RESUMO

The influence exerted by different pre-slaughter fasting times on the meat quality of the male and female broilers, slaughtered at 35 and 42 days of age was evaluated, using 128, randomly selected birds from a larger batch, and rearing of the same management and diets. The treatments involved a diet of 4, 8, 12 and 16 h of feed and water restrictions, prior to slaughter. For each fasting time, eight birds of each sex were slaughtered. Meat quality was evaluated by assessing the pH, meat color using a CR400 Minolta Colorimeter, shear force using a Texture Analyzer device (model TA-XT2I) and lipid peroxidation, determined by the thiobarbituric acid-reactive substances method (TBARS). Fasting times and between males and females slaughtered at 35 and 42 days ofage showed no effect and hence no difference (P>0.05) in the pH, color and shear force. With respect to lipid oxidation, no difference was reported between fasting times at 35 days of age and between males and females; however, at 42 days a difference was evident between fasting times, in both males and females, and in 12 and 16 h it was higher whencompared to 4 and 8 h of fasting. The conclusion drawn was that the fasting timesexert no effect on the pH, color and, shear force of the broiler meat. However, the lipid oxidation values were higher after 12 h of fasting in the birds slaughtered at 42 days of age.(AU)


Foi avaliada a influência de diferentes tempos de jejum pré-abate sobre a qualidade da carne de frangos de corte machos e fêmeas, abatidos aos 35 e 42 dias de idade utilizando 128 aves selecionadas aleatoriamente de um lote maior e criadas nas mesmas condições de manejo e dietas. Aves ficaram 4, 8, 12 e 16 horas com restrição alimentar e hídrica antes do abate. Para cada período de jejum foram abatidas oito aves de cada sexo. A qualidade da carne foi avaliada através do pH, cor da carne em aparelho Colorímetro CR400 Minolta, força de cisalhamento em aparelho Texture Analyzer (modelo TA-XT2I) e a peroxidação lipídica, determinada pelo método de substâncias reativas ao ácido tiobarbitúrico (TBARS). Os tempos de jejum entre machos e fêmeas abatidos aos 35 e 42 dias de idade não apresentaram diferença e não houve diferença (P>0,05) no pH, cor e força de cisalhamento. Com relação à oxidação lipídica, não foi encontrada diferença entre os tempos de jejum aos 35 dias de idade e entre machos e fêmeas; entretanto, aos 42 dias ocorreu diferença entre os tempos de jejum, tanto em machos como fêmeas, sendo que nas 12 e 16 horas foi maior quando comparado com 4 e 8 horas de jejum. Conclue-se que o tempo de jejum não exerceu efeito sobre o pH, cor e força de cisalhamento da carne de frango. Entretanto, os valores de oxidação lipídica foram maiores após 12 horas de jejum nas aves abatidas aos 42 dias de idade.(AU)


Assuntos
Animais , Masculino , Feminino , Galinhas/fisiologia , Carne/análise , Dietoterapia , Oxidação , Abate de Animais
5.
Acta Vet. Brasilica ; 17(2): 91-98, 2023. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1513109

RESUMO

The objective of this work was to evaluate the use of an ultrafine bubble generator of own manufacture for oxygenation of Nile tilapia (Oreochromis niloticus) breeding tanks in a recirculating water system. The research was divided into two steps: 1) oxygen saturation test; 2) application of ultrafine bubble production technology for the breeding of Nile tilapia. In the first step, the water of a 2.0 m3 test tank was completely deoxygenated and the ultrafine bubble generator was turned on for 60 min. In the second step, the generator was connected to the water recirculating system for breeding of Nile tilapia to compare the overall performance of this system with other under conventional aeration system. The ultrafine bubble generator could reach 100% oxygen saturation in the test tank (27.8 °C) in approximately 21 min and, at the end of 60 min, the concentration was 21.8 mg L-1 (277.52% saturation). The results showed significant difference (p<0.05) between the mean dissolved oxygen concentration in the treatment with ultrafine bubbles (9.80 ±3.68 mg L-1) and the treatment with conventional aeration (3.47 ± 0.88 mg L-1). No significant difference (p>0.05) was found for the zootechnical performance parameters evaluated. The conclusion was that the ultrafine bubble generator is more efficient to maintain a high dissolved oxygen concentration in the recirculating water in Nile tilapia breeding tanks than the conventional aeration system


O objetivo da presente pesquisa foi avaliar a utilização do gerador de bolhas ultrafinas (fabricação própria) para oxigenação de tanques de criação de tilápia do Nilo em sistema de recirculação de água. A pesquisa foi dividida em duas etapas: 1) teste de saturação de oxigênio; 2) aplicação da tecnologia de produção de bolhas ultrafinas na criação da tilápia do Nilo. Na primeira, a água de um tanque teste (2,0 m³) foi completamente desoxigenada e o gerador de bolhas ultrafinas acionado por um período de 60 min. Na segunda, o gerador foi ligado a um sistema de recirculação para criação de tilápia para comparar o desempenho geral desse sistema ao de outro no qual utilizou-se aeração convencional. O gerador de bolhas ultrafinas foi capaz de atingir 100% de saturação de oxigênio no tanque teste (27,8 °C) em aproximadamente 21 min e, ao final de 60 min, a concentração foi 21,8 mg/L (saturação 277,52%). Foi observada diferença significativa (p<0,05) entre a concentração média de oxigênio dissolvido no tratamento com bolhas ultrafinas (9,80 ± 3,68 mg/L) e o tratamento com aeração convencional (3,47 ± 0,88 mg/L). Não foi observada diferença significativa (p>0,05) para nenhum dos parâmetros de desempenho zootécnico avaliados. Pode-se concluir que o gerador de bolhas ultrafinas é mais eficiente em manter alta a concentração de oxigênio dissolvido em tanques de criação de tilápia em sistema de recirculação de água quando comparado ao sistema convencional de aeração


Assuntos
Animais , Aeração/métodos , Recirculação da Água , Oxigenação , Ciclídeos/fisiologia , Pesqueiros
6.
São José dos Campos; s.n; 2023. 79 p. ilus, tab.
Tese em Português | BBO - Odontologia | ID: biblio-1437678

RESUMO

A irradiação da dentina com o laser Nd:YAG mostra-se promissora para a qualidade da adesão, desde que aplicada sob parâmetros específicos e em etapas definidas. O objetivo deste estudo é avaliar de forma comparativa, o impacto da irradiação com laser de Nd:YAG sobre a formação e estabilidade da camada híbrida em dentina humana, pré-tratada com ácido e primer de sistema adesivo convencional, "in vitro". Setenta molares hígidos tiveram suas raízes e porções coronárias seccionadas horizontalmente, até completa exposição de dentina oclusal. As amostras foram divididas em: G1 (controle n=20); G2 (experimental n=20), sendo 10 dentes de cada grupo destinados ao microcisalhamento (MC) e 10 dentes à microscopia eletrônica de varredura (MEV). Nos 30 dentes restantes analisou-se: textura por Tomografia Computadorizada de Feixe Cônico (AT=15); e Espectroscopia de Infravermelho por Transformada de Fourier (FTIR=15) em 3 momentos: dentina controle; após tratamento com ácido + primer; e posterior à irradiação a laser. Estatisticamente, optou-se por ANOVA 1 fator, Qui Quadrado de Pearson, teste T e múltiplas comparações de Tukey com significância de 5%. A FTIR evidenciou redução dos níveis de fosfato e carbonato nos momentos primer e após irradiação laser, porém não havendo desnaturação do colágeno exposto. A análise de textura evidenciou uma tendência à formação de um tecido mais padronizado após o uso do laser. O teste de MC evidenciou valores médios de 36,5 e 35,2MPa para G1 e G2 respectivamente (p>0,05) e portanto, de forma imediata, o laser não mostrou efeitos deletérios ao processo adesivo. Além disso, observou-se maior penetrabilidade do adesivo na avaliação em MEV após a aplicação do laser. Novas pesquisas com avaliação longitudinal mostram-se necessárias para verificar se o efeito do laser pode ter sido protetor da degradação hidrolítica, visto que há uma redução do conteúdo de água local durante a formação da camada híbrida (AU).


Irradiation of dentin with the Nd:YAG laser shows promise for the quality of adhesion, as long as it is applied under specific parameters and in defined steps. The objective of this study is to comparatively evaluate the impact of irradiation with Nd:YAG laser on the formation and stability of the hybrid layer in human dentin, pretreated with acid and primer of conventional adhesive system, "in vitro". Seventy healthy molars had their roots and coronal portions horizontally sectioned, until complete exposure of occlusal dentin. The samples were divided into: G1 (control n=20); G2 (experimental n=20), with 10 teeth from each group destined for microshearing (MC) and 10 teeth for scanning electron microscopy (SEM). In the 30 remaining teeth analyzed: texture by Cone Beam Computed Tomography (AT=15); and Fourier Transform Infrared Spectroscopy (FTIR=15) in 3 moments: dentin control; after treatment with acid + primer; and after laser irradiation. Statistically, we opted for 1-way ANOVA, Pearson's Chi Square, T test and Tukey's multiple comparisons with a significance of 5%. FTIR showed a reduction in phosphate and carbonate levels in the primer moments and after laser irradiation, but there was no denaturation of the exposed collagen. The texture analysis evidenced a trend towards the formation of a more expressive tissue after the use of the laser. The CM test showed mean values of 36.5 and 35.2MPa for G1 and G2 respectively (p>0.05) and therefore, immediately, the laser showed no deleterious effects on the adhesive process. In addition, greater penetrability of the adhesive was observed in the SEM evaluation after laser application. New studies with longitudinal evaluation are necessary to verify if the laser effect could have been protected from hydrolytic degradation, since there is a reduction in the local water content during the formation of the hybrid layer (AU).


Assuntos
Adesivos Dentinários , Espectroscopia de Infravermelho com Transformada de Fourier , Resistência ao Cisalhamento , Tomografia Computadorizada de Feixe Cônico , Lasers de Estado Sólido
7.
Ortho Sci., Orthod. sci. pract ; 16(61): 72-79, 2023. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-1509310

RESUMO

Resumo A produção contemporânea de bráquetes ortodônticos inclui tecnologia de injeção, com diferentes desenhos de base de colagem que interferem, diretamente, na força de adesão ao esmalte e na facilidade de remoção posterior. O objetivo foi avaliar a resistência ao cisalhamento de bráquetes metálicos de três diferentes bases de colagem, verificando a força necessária para descolagem e o remanescente de resina na base do bráquete. Foram utilizados 30 dentes bovinos, colados com bráquetes U-Clip (Orthometric, Marília, SP, Brasil); ID-ALL (ID-Logical, São José do Rio Preto, SP, Brasil) e Mini Twin, (3M ESPE, St Paul, Minnesota, EUA). Todos os bráquetes foram colados com a resina Transbond XT®, (3M ESPE, St Paul, Minnesota, EUA). Após a colagem, os corpos de prova foram submetidos ao teste de cisalhamento, com registro das forças de descolagem e, posteriormente, foram avaliados o adesivo remanescente e o padrão de falha em um estereomicroscópio óptico. As forças de cisalhamento foram semelhantes entre os grupos U-Clip e ID-ALL, que foram estatisticamente diferentes do grupo Mini-Twin. Os bráquetes U-Clip e Mini-Twin apresentaram todo o remanescente de resina aderido à base do bráquete, enquanto o bráquete ID-ALL apresentou mais da metade do remanescente aderido à base do bráquete, resultado estatisticamente significante. Conclui-se os bráquete nacionais apresentam menor força de cisalhamento, estatisticamente significante quando comparados ao bráquete Mini-Twin. O bráquete ID-ALL apresentou o menor remanescente de resina, denotando que a fratura ocorreu na camada de resina, enquanto que nos grupos U-Clip e Mini-Twin, a fratura ocorreu na interface resina/esmalte. (AU)


Abstract The contemporary production of orthodontic brackets includes injection technology, with different designs of bonding bases that interfere directly with the bond strength to enamel and the ease of subsequent removal. The aim was to evaluate the shear bond strength of metal brackets of three different bonding bases, checking the force required for debonding and the rates of resin remaining on the bracket base. The sample consisted of 30 bovine teeth bonded with brackets U-Clip (Orthometric, Marília, SP, Brazil), ID-ALL (ID-Logical, São José do Rio Preto, SP, Brazil), and Mini Twin (3M ESPE, St Paul, Minnesota, USA). All brackets were bonded with Transbond XT resin (3M ESPE, St Paul, Minnesota, USA). After bonding, the specimens were subjected to a shear bond test. The forces required for debonding were recorded. Posteriorly, the remaining adhesive and failure patterns were evaluated in an optical stereomicroscope. The shear forces were similar for U-Clip and ID-ALL, which were significantly different from the Mini-Twin group. The U-Clip and Mini-Twin brackets showed the resin remnant totally adhered to the bracket base, while the ID-ALL bracket had more than half of the resin remnant attached to the bracket base, a statistically significant result. It was concluded that shear forces were lower for the national brackets, statistically significant. Bracket ID-ALL had the least resin remnant in the base, denoting that the fracture occurred in the resin layer. In contrast, in the U-Clip and Mini-Twin brackets groups, the fracture occurred at the resin/enamel interface (AU)


Assuntos
Animais , Bovinos , Ortodontia , Braquetes Ortodônticos , Esmalte Dentário , Resistência ao Cisalhamento
8.
Belo Horizonte; s.n; 2023. 50 p. ilus.
Tese em Português | BBO - Odontologia | ID: biblio-1516448

RESUMO

Poliéter-éter-cetona (Polyetheretherketone - PEEK) é um polímero de excelentes propriedades mecânicas, o que o torna um potencial candidato para substituir ligas metálicas em diversas especialidades odontológicas. Quando utilizado como infraestrutura para confecção de próteses odontológicas, a adesão do PEEK ao material de revestimento estético é determinante para a longevidade do tratamento, embora a baixa energia de superfície e grande estabilidade química do polímero tornem essa adesão um desafio a ser superado. Objetivo: Responder à pergunta: "Outros tratamentos de superfície do PEEK geram resistências de união superiores ao adesivo comercial?" Métodos: A busca foi feita nas bases Pubmed, , LILACS, Scopus, Web of Science, EMBASE, ProQuest e Google Scholar em junho de 2023 e não houve restrição relativa ao idioma ou à data de publicação dos estudos. Foram utilizados os seguintes termos e operadores booleanos: "polyether ether ketone" [MH] OR "polyether ether ketone" OR "polyetheretherketone" OR "polyetherketoneketone" OR "PEEK" AND "shear strength" [MH] OR "shear strength" OR "shear bond strength" OR "tensile bond strength" OR "shear" OR "tensile" OR "microtensile" OR "microshear" OR "bonding" OR "bond strength" OR "microtensile strength" OR "microshear bond strength" OR "bond" OR "adhesion" OR "bond integrity" OR "bonded" OR "Bonding Strength" OR "Bonding Behavior" OR "Adhesive Performance" OR " surface bonding" OR "tensile strength" [MH] OR "tensile strength". Foram incluídos exclusivamente estudos in vitro. Resinas compostas e resinas acrílicas foram consideradas como materiais de revestimento para PEEK. A média e o desvio padrão expressos em MPa e obtidos a partir de testes de cisalhamento e tração foram utilizados para relatar a resistência de união entre o PEEK e os materiais de revestimento. As meta-análises foram realizadas e a ferramenta Cochrane Collaboration avaliou o risco de viés (RoBDEMAT). Resultados: Foram selecionados 23 estudos. A resistência de união entre PEEK e resina composta foi favorecida pelo uso do adesivo (P<0,00001), independentemente do tipo de adesivo. O pré-tratamento com jato de areia Al2O3 (P<0,00001), ácido sulfúrico (P<0,00001), plasma frio (P=0,0006) e laser (P<0,00001) mostrou-se eficiente, embora o condicionamento com solução piranha não tenha tido efeito estatisticamente significativo (P=0,47). Conclusão: A aplicação de ácido sulfúrico antes do adesivo apresentou melhores resultados de resistência de união em comparação ao uso isolado do adesivo.


Polyether-ether-ketone (Polyetheretherketone - PEEK) is a polymer with excellent mechanical properties, which makes it a potential candidate to replace metallic alloys in several dental specialties. When used as an infrastructure for the manufacture of dental prostheses, the adhesion of PEEK to the aesthetic coating material is decisive for the longevity of the treatment, although the low surface energy and great chemical stability of the polymer make this adhesion a challenge to be overcome. Objective: Answer the question: "Do other PEEK surface treatments generate bond strengths superior to commercial adhesive?" Methods: The search was carried out in the Pubmed, LILACS, Scopus, Web of Science, and EMBASE, ProQuest and Google Scholar databases in June 2023 and there were no restrictions regarding the language or publication date of the studies. The following terms and bolean operators were used: "polyether ether ketone" [MH] OR "polyether ether ketone" OR "polyetheretherketone" OR "polyetherketoneketone" OR "PEEK" AND "shear strength" [MH] OR "shear strength" OR " shear bond strength" OR "tensile bond strength" OR "shear" OR "tensile" OR "microtensile" OR "microshear" OR "bonding" OR "bond strength" OR "microtensile strength" OR "microshear bond strength" OR "bond" OR "adhesion" OR "bond integrity" OR "bonded" OR "Bonding Strength" OR "Bonding Behavior" OR "Adhesive Performance" OR "surface bonding" OR "tensile strength" [MH] OR "tensile strength". Only in vitro studies were included. Composite resins and acrylic resins were considered as coating materials for PEEK. The mean and standard deviation expressed in MPa and obtained from shear and tensile tests were used to report the bond strength between PEEK and coating materials. Meta-analyses were performed and the Cochrane Collaboration tool assessed the risk of bias (RoBDEMAT). Results: 23 studies were selected. The bond strength between PEEK and composite resin was favored by the use of the adhesive (P<0,00001), regardless of the type of adhesive. Pretreatment with Al2O3 sandblasting (P<0,00001), sulfuric acid (P<0,00001), cold plasma (P=0,0006) and laser (P<0,00001) proved to be efficient, although conditioning with piranha solution did not have a statistically significant effect (P=0,47). Conclusion: The application of sulfuric acid before the adhesive showed better results in bond strength compared to the use of the adhesive alone.


Assuntos
Polímeros , Resistência à Tração , Resinas Acrílicas , Resinas Compostas , Resistência ao Cisalhamento
9.
Ortho Sci., Orthod. sci. pract ; 16(64): 82-89, 2023. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-1551916

RESUMO

Resumo OBJETIVO: Avaliar a resistência ao cisalhamento e o Índice de Remanescente Adesivo (IRA) de bráquetes metálicos colados com três diferentes fotopolimerizadores LED de alta potência, quando comparados ao LED convencional. MATERIAIS E MÉTODOS: 80 incisivos bovinos foram divididos aleatoriamente em 4 grupos (n=20), nos quais foram realizadas colagens dos bráquetes utilizando-se os seguintes LEDs de alta potência por 3s: Grupo 1 ­ LEDX ­ T 2400, Orthometric; Grupo 2 ­ Flashmax P4 PRO Ortho, Rock Moutain Orthodontics; Grupo 3 ­ VALO CORDLESS, Ultradent e Grupo 4 ­ LED convencional por 40s (controle) POLY-WIRELESS, Kavo. O teste de resistência ao cisalhamento foi realizado utilizando-se uma máquina de ensaio universal (AME-2kN, Oswaldo Filizola, São Paulo, Brasil) com velocidade de 0,5mm/min e célula de carga de 50N. A determinação da diferença estatística entre os grupos em relação ao cisalhamento foi realizada usando-se a análise de variância (ANOVA). Para avaliação do IRA, foi aplicado o teste Kruskal-Wallis. RESULTADOS: O grupo 2 apresentou resistência ao cisalhamento significativamente superior aos demais LEDs de alta potência e foi similar ao LED convencional. Em relação ao IRA, houve diferença estatisticamente significante entre os grupos e o único que não diferiu do grupo controle foi o 2, enquanto os demais LEDs de alta potência (Grupos 1 e 3) apresentaram mais falhas adesivas entre a resina e o esmalte. CONCLUSÃO: Houve diferença entre os três tipos de fotopolimerizadores LED de terceira geração, sendo que maior resistência ao cisalhamento e menos falhas adesivas foram observadas no LED que apresentou maior potência (AU)


Abstract OBJECTIVE: To evaluate shear strength and Adhesive Remnant Index (ARI) of metallic brackets bonded to three types of high-power LED light curing, when compared to conventional LED. MATERIALS AND METHODS: 80 bovine incisors were divided into 4 groups (n = 20), in which brackets were bonded using the following high-power LEDs for 3s: Group 1 ­ LEDX ­ T 2400, Orthometric; Group 2 ­ Flashmax P4 PRO Ortho, Rock Mountain Orthodontics; Group 3 ­ VALO CORDLESS, Ultradent; and Group 4 ­ conventional LED for 40s (control) POLY-WIRELESS, Kavo. The shear strength test was performed using a universal test machine (AME-2kN, Oswaldo Filizola, São Paulo, Brasil) with 0.5 mm/min speed and 50N load cell. The determination of statistical difference between the groups in relation to shear strength was performed using analysis of variance (ANOVA). The Kruskal-Wallis test was used to assess the IRA. RESULTS: Group 2 showed shear strength significantly higher than other high-power LEDs and was similar to conventional LED. Regarding ARI, there was a statistically significant difference between the groups and the only one that did not differ from the control group was 2, while the other high-power LEDs (Groups 1 and 3) had more adhesive failures between the resin and the enamel. CONCLUSION: There was a difference between the three types of third generation LED light curing agents, with greater shear strength and less adhesive failures observed in the LED that presented higher power. (AU)


Assuntos
Braquetes Ortodônticos , Resistência ao Cisalhamento , Cura Luminosa de Adesivos Dentários
10.
Ortho Sci., Orthod. sci. pract ; 16(64): 101-105, 2023. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-1551963

RESUMO

Resumo Objetivou-se avaliar in vitro a resistência ao cisalhamento (RUC) do bráquete ortodôntico associado ao elástico Guard como absorvedor de impactos e o índice de remanescente adesivo (IRA). Sessenta pré-molares humanos foram selecionados e distribuídos aleatoriamente em três grupos (n = 20): G1) sem elástico; G2) com elástico convencional (3M Unitek) e G3) com elástico Guard (3M Unitek). Os bráquetes Kirium Roth 0.22 (3M ESPE) foram fixados no terço médio da face vestibular do dente com resina Transbond XT (3M Unitek) e fotoativados por 3 segundos em cada face do bráquete com o dispositivo Valo (Ultradent). Após armazenamento por 24 horas, as amostras foram submetidas a uma velocidade de 1 mm/minuto. Os bráquetes foram retirados e o IRA avaliado em estereomicroscópio (Olympus) em aumento de 8x. Os dados do RUC foram submetidos à análise de variância e teste de Tukey (α = 0,05), e os dados ARI foram submetidos ao teste exato de Fisher. G3 mostrou valores RUC (20,1 ± 4,5) significativamente mais elevados do que o Grupo G1 sem elástico (15,3 ± 3,7) (P < 0,05). Não foi observada diferença estatística entre G2 (16,9 ± 6,0) e os demais grupos (P > 0,05). Não houve diferença significativa entre os grupos na avaliação do IRA (P = 0,3303). Em conclusão, a resistência ao cisalhamento do bráquete foi maior quando associado ao elástico Guard, sendo estatisticamente significante em relação aos bráquetes sem elástico. Menos da metade da resina permaneceu no dente em todos os grupos estudados para o IRA.(AU)


Abstract This in vitro study aimed to evaluate the shear bond strength (RUC) of the orthodontic bracket associated with the Guard elastic as an impact absorber and the remaining adhesive index (ARI). Sixty human premolars were selected and randomly distributed in three groups (n = 20): G1) without elastic; G2) with conventional elastic (3M Unitek); and G3) with Guard elastic (3M Unitek). Kirium Roth slot brackets 0.22 inch (3M ESPE) was fixed to the middle third of the buccal face of the tooth with Transbond XT resin (3M Unitek) and photoactivated for 3 seconds on each bracket face with the Valo (Ultradent) device. After storage for 24 hours, the samples were subjected to a speed of 1 mm/minute. The brackets were taken off, and the ARI was evaluated in a tereomicroscope (Olympus) in 8x magnification. The RUC data were subjected to analysis of variance and Tukey's test (α = 0.05), and ARI data were subjected to Fisher's exact test. G3 showed RUC values (20.1 ± 4.5) significantly higher than the group without elastic G1 (15.3 ± 3.7) (P < 0.05). No statistical difference was observed between G2 (16.9 ± 6.0) and the other groups (P > 0.05). There was no significant difference between groups in the assessment of ARI (P = 0.3303). In conclusion, completing the RUC of the Guard and the conventional elastic band was superior concerning the other groups. Less than half of the resin remained in the tooth in all groups studied for the ARI. (AU)


Assuntos
Ortodontia , Braquetes Ortodônticos , Resistência ao Cisalhamento
11.
Ciênc. anim. bras. (Impr.) ; 24: e-75322E, 2023. tab
Artigo em Inglês | VETINDEX | ID: biblio-1447891

RESUMO

The aim was to evaluate the effect of replacing ground corn with spineless cactus from two species Orelha de Elefante Mexicana-OEM (Opuntia stricta Haw.) and Gigante (Opuntia ficus-indica Mill) in a total mixed ration for finishing lambs evaluating its effects on intake, ingestive behavior, performance, carcass traits, commercial cuts and physiochemical composition of the meat. Eighteen crossbred lambs with average body weight of 15.0 ± 2.32 kg were distributed in a completely randomized design with three treatments (OEM and Gigante spineless cactus and ground corn as control treatment) and six replications. Spineless cactus species replacing ground corn in lambs diets does not change the intake of dry matter (DMI), crude protein and neutral detergent fiber or time (min/d) of ingestion, rumination and idleness, or final body weight gain. Lambs fed with ground corn and "Gigante" cactus presented a higher total weigh gain (TWG) and average daily weight gain (ADG) when compared to OEM spineless specie. Ground corn diet promoted better hot and cold carcass yield in lambs receiving spineless cactus, regardless of species. Feed and total costs (kg/lamb) were higher for the ground corn diet. The replacement of ground corn with spineless cactus did not change moisture, protein, and ash meat contents, as well as water holding capacity, cooking loss, shear force, and a* color intensity. However, there was an effect for the meat lipid content, b* and L* color intensity and color index, where the species of cactus Gigante on ground corn presented the highest lipid content and yellowness (b*) intensity and lower L* color compared to OEM. Spineless cactus species Gigante can replace ground corn as a source of energy in diets for finishing lambs because it significantly improves the financial income for the producer without changing the ADG, DMI, ingestive behavior and yield of commercial cuts.


Objetivou-se avaliar o efeito da substituição do milho moído por duas espécies de palma forrageira, Orelha de Elefante Mexicana-OEM (Opuntia stricta Haw.) e espécie Gigante (Opuntia ficus-indica Mill) em uma ração completa para terminação de cordeiros avaliando seus efeitos sobre consumo, comportamento ingestivo, desempenho, características de carcaça, cortes comerciais e composição físico-química da carne. Foram utilizados dezoito cordeiros sem padrão racial definido com peso corporal médio de 15,0 ± 2,32 kg e foram distribuídos em delineamento inteiramente casualizado com três tratamentos (OEM e palma Gigante e grão de milho como controle) e seis repetições. As duas espécies de palma forrageira em substituição ao milho moído na dieta de cordeiros não modificaram o consumo de matéria seca (CMS) proteína bruta e fibra em detergente neutro nem o tempo (min/dia) de ingestão, ruminação e ócio ou ganho corporal final. Cordeiros alimentados com milho moído e palma Gigante apresentaram maior ganho de peso total (GPT) e médio diário (GMD) em relação à espécie OEM. A dieta com milho moído promoveu melhor rendimento de carcaça quente e fria comparando cordeiros recebendo palma forrageira, independente da espécie. Os custos com ração e total (kg/cordeiro) foram maiores para a dieta com milho moído. A substituição do milho moído pela palma forrageira não alterou os teores de umidade, proteína e cinzas da carne, bem como a capacidade de retenção de água, perda por cozimento, força de cisalhamento e intensidade de cor a*. No entanto, houve efeito para o teor de lipídios da carne, índice de intensidade de cor b* e L*, sendo que a espécie de palma Gigante e o milho grão moído apresentou o maior teor de lipídios e intensidade de amarelo (b*) e menor cor L* em relação ao OEM. A espécie palma forrageira Gigante pode substituir o milho moído como fonte de energia em dietas para cordeiros em terminação, pois melhora significativamente o rendimento financeiro do produtor sem alterar o GMD, CMS, comportamento ingestivo e rendimento dos cortes comerciais.


Assuntos
Animais , Ovinos , Zea mays , Opuntia , Dieta/veterinária , Ração Animal
12.
São José dos Campos; s.n; 2023. 79 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1443514

RESUMO

O objetivo deste estudo foi desenvolver e avaliar um adesivo resinoso modificado com a incorporação de partículas de vidro bioativas (SCHOTT Bioactive Glass) em diferentes concentrações. Foram avaliados a resistência ao cisalhamento (RU), o índice de remanescente dentário (IRA), o grau de conversão (GC) e a liberação de cálcio. Foram utilizados 50 incisivos bovinos que foram fixados, através de suas raízes, em um molde de PVC, com resina acrílica autopolimerizável. As amostras foram alocadas em 5 grupos (n=10): TXT - Adesivo Transbond XT (3M Unitek, Monrovia, CA, EUA) sem adição de partículas de vidro bioativas, TXT20, TXT30, TXT50 ­ Adesivo Transbond XT acrescido respectivamente de 20%, 30% e 50% de partículas de vidro bioativas e SH - Adesivo resinoso FL BOND ll (SHOFU Inc.) com biomaterial SPRG. As amostras receberam uma profilaxia com pedra pomes e condicionamento com ácido fosfórico à 37%. Em seguida foi aplicada uma fina camada do sistema adesivo indicado na face vestibular dos incisivos bovinos, em todos os grupos e fotopolimerizado por 20 segundos, utilizando-se um fotopolimerizador RADII-Cal (SDI, Victoria, Austrália). Depois foi aplicada uma pequena quantidade de pasta resinosa fotopolimerizável Transbond XT (3M Unitek, Monrovia, CA, EUA) sobre a superfície dos bráquetes autoligados (MORELLI, Sorocaba, São Paulo, Brasil) e estes foram devidamente colados na face vestibular, no centro da coroa clínica do incisivo bovino e fotopolimerizado por 20 segundos, em cada face. Posteriormente as amostras foram submetidas ao teste de resistência ao cisalhamento. O índice de remanescente adesivo foi avaliado em estereomicroscópio DISCOVERY V20 (ZEISS). Os adesivos resinosos foram submetidos ao teste de grau de conversão e liberação de cálcio. Os dados foram inicialmente submetidos ao teste de normalidade e depois submetidos ao teste de ANOVA um fator, seguido do teste de Tukey para análise de comparações múltiplas, com nível de significância de 0,05. De acordo com os resultados obtidos na resistência de união ao cisalhamento (MPa±Dp) a maior média foi observada no grupo TXT 19,50±1,40A, seguida do grupo TXT20 18,22±1,04AB, seguida do grupo SH 17,62±1,45B, seguida do grupo TXT30 14,48±1,46C e a menor média TXT50 14,13±1,02C. No grau de conversão a maior média foi observada no grupo TXT20 73,02±3,33A que foi estatisticamente semelhante ao grupo SH 68,50±1,09A, seguida do grupo TXT 60,28±1,06B e TXT30 58,84±4,06B e a menor média foi do grupo TXT50 40,67±1,21C.Para a liberação de cálcio a maior média foi TXT50 2,23±0,11D, seguida por TXT30 0,74±0,00C, TXT20 0,55±0,00B, SH 0,47±0,04B e TXT 0,14±0,00A. Concluiu-se que a incorporação de partículas de vidro bioativas influenciou na resistência de união ao cisalhamento, no grau de conversão e na liberação de cálcio (AU).


The objective of this study was to develop and evaluate a resin adhesive modified with the incorporation of bioactive glass particles (SCHOTT Bioactive Glass) in different concentrations. Shear bond strength (SBS), adhesive remnant index (ARI), degree of conversion (DC) and calcium release were evaluated. Fifty bovine incisors were used, which were fixed through their roots in a PVC mold with self-curing acrylic resin. The samples were allocated into 5 groups (n=10): TXT ­ Transbond XT Adhesive (3M Unitek, Monrovia, CA, USA) without addition of bioactive glass particles, TXT20, TXT30, TXT50 ­ Transbond XT Adhesive rescpectively increased by 20%, 30% and 50% bioactive glass particles and SH ­ FL BOND ll resin adhesive (SHOFU Inc.) with SPRG biomaterial. The samples received prophylaxis with pumice stoe and conditioning with 37% phosphoric acid. Then, a thin layer of the indicated adhesive system was applied to the buccal surface of the bovine incisors, in all groups, and light cured for 20 seconds, using a RADII-Call curing light (SDI, Victoria, Australia). Then, a small amount of Transbond XT light-curing resinous paste (3M Unitek, Monrovia, CA, USA) was applied on the surface of the self-ligating brackets (MORELLI, Sorocaba, São Paulo, Brazil) and these were duly bonded on the buccal surface, in the center of the clinical crown of the bovine incisor and light cured for 20 seconds, on each side. Subsequently, the samples were submitted to the shear bond test. The adhesive remnant index was evaluated using a DISCOVERY V20 stereomicroscope (ZEISS). The resin adhesives were submitted to the degree of conversion and calcium release test. The data were initially submitted to the normality test and then submitted to the one-way ANOVA test, followed by the Tukey test for analysis of multiple comparisons, with a significance level of 0.05. According to the results obtained in the shear bond strength (MPa±Dp), the highest average was observed in the TXT group 19.50±1.40A, followed by the TXT20 group 18.22±1.04AB, followed by the SH group 17.62±1.45B, followed by the TXT30 group 14.48±1.46C and the lowest mean TXT5014.13±1.02C. In the degree of conversion, the highest average was observed in the TXT20 73.02±3.33A group, wich was statiscally like the SH group 68.50±1.09A, followed by the TXT 60.28±1.06B and TXT30 group 58.84±4.06B and the lowest mean was for the TXT50 group 40.67±1.21C. For calcium release, the highest mean was TXT50 2.23±0.11D, followed by TXT30 0.74±0.00C, TXT20 0.55±0.00B, SH 0.47±0.04B and TXT 0.14±0.00A. It was concluded that the incorporation of bioactive glass particles influenced in the shear bond strength, in the degree of conversion and in the release of calcium (AU).


Assuntos
Animais , Bovinos , Ortodontia , Resistência ao Cisalhamento
13.
Braz. dent. sci ; 26(3): 1-13, 2023. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1437871

RESUMO

Objective: to evaluate the effect of novel zirconia surface treatment method on shear bond strength between zirconia and veneering porcelain compared to air abrasion and CoJet surface treatment methods. Material and Methods: twenty-one zirconia ceramic discs were fabricated with diameter of 7mm and 3mm thickness and divided according to surface treatment into three subgroups, control group I: Air Abrasion (n=7), group II: CoJet (n=7) and group III: Z-etch (n=7). Porcelain was built over the zirconia specimens with a customized mold and fired in a ceramic furnace. All specimens were thermocycled (20000 cycles) between 5°C ­ 55 °C with a dwell time of 30 seconds in distilled water and shear bond strength of veneering porcelain to each zirconia specimen was tested using a universal testing machine. Results: numerical data were explored for normality by checking the distribution of data and using tests of normality (Kolmogorov-Smirnov and Shapiro-Wilk tests). One-way ANOVA test was used to compare between the groups. There was a statistically significant difference between the three groups (P-value = 0.002, Effect size = 0.503). Pair-wise comparisons between groups revealed that Z-etch showed the statistically significantly highest mean shear bond strength. Conclusion: zirconia coating using z-etch is showing promising results in promoting higher bond strength than conventional surface treatment methods as air abrasion and silica coating (AU)


Objetivo: avaliar o efeito do novo método de tratamento de superfície de zircônia na resistência ao cisalhamento entre a zircônia e a porcelana de cobertura em comparação com os métodos de abrasão a ar e jateamento com CoJet. Material e Métodos: vinte e um discos de zircônia foram confeccionados com diâmetro de 7mm e espessura de 3mm e divididos de acordo com o tratamento de superfície em três subgrupos, grupo controle I: Abrasão a ar (n=7), grupo II: CoJet (n=7) e grupo III: Z-etch (n=7). A porcelana foi aplicada sobre os espécimes de zircônia com um molde personalizado e sinterizada em forno de cerâmica. Todos os espécimes foram termociclados (20.000 ciclos) entre 5°C - 55°C com um tempo de permanência de 30 segundos em água destilada e a resistência ao cisalhamento da porcelana de cobertura foi testada através de uma máquina de ensaio universal. Resultados: os dados numéricos foram avaliados quanto à normalidade, verificando a distribuição dos dados e utilizando testes de normalidade (testes de Kolmogorov-Smirnov e Shapiro-Wilk). O teste ANOVA de um fator foi utilizado para comparar os grupos. Houve uma diferença estatisticamente significativa entre os três grupos (P-valor = 0,002, tamanho do efeito = 0,503). As comparações pareadas entre os grupos revelaram que o Z-etch apresentou a resistência de união ao cisalhamento estatisticamente significativamente mais alta. Conclusão: o revestimento de zircônia utilizando Z-etch mostrou resultados promissores para o aumento da resistência de união em comparação aos métodos convencionais de tratamento de superfície, como abrasão a ar e revestimento de sílica (AU)


Assuntos
Abrasão Dental por Ar , Resistência ao Cisalhamento , Materiais Dentários
14.
Braz. dent. sci ; 26(3): 1-16, 2023. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1442916

RESUMO

Statement of problem: the bond strength between adhesive cement and root dentin can be affected by irrigation protocols. Purpose: therefore, the objective of this systematic review was to answer the following question: Do irrigation solutions used during root canal instrumentation influence the adhesion of glass fiber posts to root dentin? Material and Methods: this study followed the recommendations of PRISMA 2020 for writing. PubMed, Scopus, Web of Science, and LILACS databases were searched for articles published until 26 January, 2022. Grey literature and a manual search were also performed. The inclusion criteria were based on the PICO strategy: permanent human or animal teeth (P), which were irrigated during root canal instrumentation with endodontic substances (I) and compared to irrigation with sodium hypochlorite at various concentrations (C) to analyze the bond strength of glass fiber posts (O). Two authors independently performed data extraction and the risk of bias. Results: eight articles were included. Four articles were classified as having a high risk of bias, where the others as medium risk. Studies have reported conflicting results regarding the influence of irrigating solutions and the different concentrations of sodium hypochlorite on the adhesion of glass fiber posts to root dentin. Conclusion: the heterogeneity between studies did not allow the conclusion of a true estimate regarding this topic, and further well-designed studies are needed to clarify this issue. Register: CRD42020221835. (AU)


Definição do problema: a resistência de união entre o cimento adesivo e a dentina radicular pode ser afetada pelos protocolos de irrigação. Objetivo: portanto, o objetivo desta revisão sistemática foi responder à seguinte questão: As soluções de irrigação usadas durante a instrumentação do canal radicular influenciam a adesão de pinos de fibra de vidro à dentina radicular? Material e Métodos: este estudo seguiu as recomendações do PRISMA 2020 para sua redação. As bases de dados PubMed, Scopus, Web of Science e LILACS foram pesquisadas para artigos publicados até 26 de janeiro de 2022. A literatura cinza e uma pesquisa manual também foram realizadas. Os critérios de inclusão foram baseados na estratégia PICO: dentes humanos ou animais permanentes (P), que foram irrigados durante a instrumentação do canal radicular com substâncias endodônticas (I) e comparados à irrigação com hipoclorito de sódio em várias concentrações (C) para analisar a resistência de união de pinos de fibra de vidro (O). Dois autores realizaram independentemente a extração de dados e o risco de viés. Resultados:oito artigos foram incluídos. Quatro artigos foram classificados como de alto riscode viés, enquanto os demais como de médio risco. Estudos relataram resultados conflitantes sobre a influência de soluções irrigadoras e as diferentes concentrações de hipoclorito de sódio na adesão de pinos de fibra de vidro à dentina radicular. Conclusão: a heterogeneidade entre os estudos não permitiu a conclusão de uma estimativa verdadeira sobre este tópico, sendo necessários mais estudos bem delineados para esclarecer esta questão. Registo: CRD42020221835 (AU)


Assuntos
Irrigantes do Canal Radicular , Moldes Cirúrgicos , Resistência ao Cisalhamento , Dentina
15.
Braz. dent. sci ; 26(4): 1-10, 2023. ilus, tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1516476

RESUMO

Objective: to evaluate the effect of material type and veneer thickness on the final color and shear bond strength of PEEK bilayered restorations. Material and Methods: sixty-four square-shaped core specimens (7×7×2), were fabricated by CAD/CAM technology from two high-strength polymers, BioHPP (High-Performance Polymer, group B n=32), and Pekkton® ivory (PolyEtherKetoneKetone, group P n=32) then were veneered with resin composite (crea.lign dentin A3). Specimens from each group were divided (n=16) according to the veneer layer thickness (0.5 & 1 mm), then according to the test applied (n=8), either ΔE or shear bond strength (SBS). Specimen surfaces were treated according to the manufacturer's instructions. Specimens were veneered according to the manufacturer's instructions.The mode of failure was evaluated under a stereomicroscope at 40 x magnification after the shear bond strength test. Results: data showed parametric distribution and variance homogeneity and were analyzed using two-way ANOVA. The significance level was set at p<0.05 for all tests. Statistical analysis was performed with the R statistical analysis software version 4.3.1.Results of two-way ANOVA showed that material types and veneer thicknesses had an individual significant effect on the color change. For the shear bond strength, only the sample thickness (1mm) had a significant effect (p=0.033). The majority of samples in different groups presented a mixed failure mode with all the differences being not statistically significant (p>0.05). Conclusion: the thickness of the resin composite veneer can significantly affect the final esthetic outcome and shear bond strength of a bilayered restoration.(AU)


Objetivo: avaliar o efeito do tipo de material e da espessura do revestimento na cor final e na resistência ao cisalhamento de restaurações em duas camadas de PEEK. Material e Métodos: foram fabricados 64 espécimes com núcleo de formato quadrado (7x7x2) usando tecnologia CAD/CAM a partir de dois polímeros de alta resistência, BioHPP (Polímero de Alto Desempenho, grupo B n=32) e Pekkton ivory (Polieterecetona cetona, grupo P n=32), que foram então revestidos com resina composta (crea.lign dentin A3). Os espécimes de cada grupo foram divididos (n=16) de acordo com a espessura do revestimento (0,5 e 1 mm), e depois de acordo com o teste aplicado (n=8), seja ΔE ou resistência ao cisalhamento (SBS). As superfícies dos espécimes foram tratadas de acordo com as instruções do fabricante. Os espécimes foram revestidos de acordo com as instruções do fabricante. O modo de falha foi avaliado sob um estereomicroscópio com ampliação de 40x após o teste de resistência ao cisalhamento. Resultados: os dados apresentaram distribuição paramétrica e homogeneidade de variância e foram analisados por ANOVA de duas vias. O nível de significância foi estabelecido em p<0,05 para todos os testes. A análise estatística foi realizada com o software de análise estatística R, versão 4.3.1. Os resultados da ANOVA de duas vias mostraram que os tipos de materiais e as espessuras do revestimento tiveram um efeito significativo individual na mudança de cor. Para a resistência ao cisalhamento, apenas a espessura da amostra (1mm) teve um efeito significativo (p=0,033). A maioria das amostras em diferentes grupos apresentou um modo de falha misto, com todas as diferenças não sendo estatisticamente significativas (p>0,05). Conclusão:a espessura do revestimento de resina composta pode afetar significativamente o resultado estético final e a resistência ao cisalhamento de uma restauração em duas camadas.(AU)


Assuntos
Polímeros , Resinas Compostas , Resistência ao Cisalhamento
16.
Braz. dent. sci ; 26(4): 1-10, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1516481

RESUMO

Objective: This study was conducted to evaluate the influence of the G-CEM ONE adhesive enhancing primer on the shear bond strength of self-adhesive resin cement (G-CEM ONE) to both tooth structure and two different CAD/CAM blocks (GC Initial LiSi and Cerasmart 270). Material and Methods: Forty specimens (cylindrical-shaped, 5 mm in diameter and height) were milled from both CAD/CAM blocks (20 specimens from each block type). Forty sound upper premolars were sectioned to the level of peripheral dentin, then randomly divided into four groups (n = 10): A1: GC Initial LiSi without adhesive enhancing primer; B1: Cerasmart 270 without adhesive enhancing primer; A2: GC Initial LiSi with adhesive enhancing primer; B2: Cerasmart 270 group with adhesive enhancing primer application. The CAD/CAM blocks were cemented on teeth using a self-adhesive resin cement (G-cem one). The shear bond strength was assessed using a computerized universal testing machine. A digital microscope was used to study the mode of failure. The shear bond strength values data were analyzed statistically using paired t-test and independent t-test at the significance level of (0.05). Results: A significant difference was shown in the shear bond strength values among groups (P =0.000). The highest shear bond strength value was revealed in group A2, while group B1 exhibited the lowest shear bond strength value. Conclusion: Using the adhesive enhancing primer on the tooth's surface improved the resin cement's bond strength to CAD/CAM blocks. Additionally, GC Initial LiSi exhibited higher bond strength than Cerasmart 270, with or without the primer (AU)


Objetivo: Este estudo foi conduzido para avaliar a influência do primer adesivo G-CEM ONE na resistência ao cisalhamento do cimento resinoso autoadesivo (G-CEM ONE) tanto na estrutura dentária quanto em dois diferentes blocos CAD/CAM (GC Initial LiSi e Cerasmart 270). Material e Métodos: Quarenta corpos de prova (formato cilíndrico, 5 mm de diâmetro e altura) foram fresados em blocos CAD/CAM (20 corpos de prova de cada tipo de bloco). Quarenta pré-molares superiores sadios foram seccionados até o nível da dentina mais externa e, em seguida, divididos aleatoriamente em quatro grupos (n = 10): A1: GC Initial LiSi sem primer adesivo; B1: Cerasmart 270 sem primer adesivo; A2: GC Initial LiSi com primer adesivo; B2: Grupo Cerasmart 270 com aplicação de primer adesivo. Os blocos CAD/CAM foram cimentados nos dentes com cimento resinoso autoadesivo (G-CEM ONE). A resistência ao cisalhamento foi avaliada utilizando uma máquina de ensaios universal computadorizada. Um microscópio digital foi utilizado para estudar o modo de falha. Os dados dos valores de resistência ao cisalhamento foram analisados estatisticamente por meio do teste t pareado e teste t independente ao nível de significância de (0,05). Resultados: Foi demonstrada diferença significativa nos valores de resistência ao cisalhamento entre os grupos (P =0,000). O maior valor de resistência ao cisalhamento foi revelado no grupo A2, enquanto o grupo B1 exibiu o menor valor de resistência ao cisalhamento. Conclusão:A utilização do primer adesivo na superfície dentária melhorou a resistência de união do cimento resinoso aos blocos CAD/CAM. Além disso, o GC Initial LiSi apresentou maior resistência de união que o Cerasmart 270, com ou sem primer.(AU)


Assuntos
Adesivos Dentinários , Desenho Assistido por Computador , Cimentos de Resina , Resistência ao Cisalhamento , Dentina
17.
Rev. Cient. CRO-RJ (Online) ; 7(3): 52-57, Sept. - Dec. 2022.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1437880

RESUMO

Objective: this in vitro study compared the adhesive strengths of the resin sealant with the Giomer technology sealant under salivary contamination. Materials and Methods: fifty-two bovine incisors were randomly divided into four groups (n=13): GI, a resin sealant (Fluroshield®) without salivary contamination (control of GII); GII, Fluroshield sealant + salivary contamination; GIII, a Giomer technology sealant (BeautiSealant®) without salivary contamination (control of GIV); and GIV, BeautiSealant® sealant + salivary contamination. In the salivary contamination groups, artificial saliva was used through a pipette, and after 20 s, it was air-dried and the sealant was applied. Shear strength tests were performed using a universal testing machine. One-way ANOVA variance and Tukey's test were used for multiple comparisons. The fracture types were analyzed using a stereomicroscope with 40X magnification. Results: the means and standard deviations (SD) of adhesion for Fluroshield® and BeautiSealant® in the group without salivary contamination were 15.27 (±0.96) and 11.90 (±0.94), and for the group with salivary contamination, 13.14 (±1.03) and 8.95 (±1.33), respectively, indicating a statistically significant difference between GI and GII p=0.020, GIII and GIV p=0.041. Mixed failures were detected in GI (38%), GII (44%), GIII (38%), and GIV (62%). Conclusion: there was a statistically significant decrease in the adhesive strength values in the groups with salivary contamination for both the sealants studied. However, no significant difference was observed between the two sealants when the materials used were compared.


Objetivo: este estudo in vitro comparou as forças adesivas do selante resinoso com o selante da tecnologia Giomer sob contaminação salivar. Materiais e Métodos: cinquenta e dois incisivos bovinos foram divididos aleatoriamente em quatro grupos (n=13): GI, um selante resinoso (Fluroshield®) sem contaminação salivar (controle do GII); GII, selante Fluroshield + contaminação salivar; GIII, um selante com tecnologia Giomer (BeautiSealant®) sem contaminação salivar (controle do GIV); e GIV, selante BeautiSealant® + contaminação salivar. Nos grupos de contaminação salivar, a saliva artificial foi utilizada por meio de uma pipeta e, após 20 s, foi seca ao ar e aplicado o selante. Os testes de resistência ao cisalhamento foram realizados usando uma máquina de teste universal. A variância ANOVA de uma via e o teste de Tukey foram usados para comparações múltiplas. Os tipos de fratura foram analisados em estereomicroscópio com aumento de 40X. Resultados: as médias e desvios padrão (DP) de adesão para Fluroshield® e BeautiSealant® no grupo sem contaminação salivar foram 15,27 (±0,96) e 11,90 (±0,94), e após contaminação salivar foram 13,14 (±1,03) e 8,95 (±1,33), respectivamente, indicando haver diferença estatisticamente significante entre GI e GII p=0.020, GIII e GIV p=0.041. Falhas mistas foram detectadas em GI (38%), GII (44%), GIII (38%) e GIV (62%). Conclusão: houve diminuição estatisticamente significativa dos valores de resistência adesiva nos grupos com contaminação salivar para ambos os selantes estudados. No entanto, não foi observada diferença significativa entre os dois selantes quando comparados os materiais utilizados.


Assuntos
Selantes de Fossas e Fissuras , Saliva Artificial , Resistência ao Cisalhamento
18.
Ortho Sci., Orthod. sci. pract ; 15(58): 100-106, 2022. tab, graf
Artigo em Português | BBO - Odontologia | ID: biblio-1380518

RESUMO

O objetivo deste estudo experimental in vitro foi avaliar a Resistência de União ao Cisalhamento (RUC) da colagem de bráquetes em diferentes tratamentos de superfície de resina composta, associados a dois agentes de união. Foram confeccionados 90 corpos de prova com resina composta Filtek Z350 (3M/ESPE). Os corpos de prova foram aleatoriamente divididos em nove grupos (n=10): (1) grupo controle; (2) silano e primer; (3) adesivo universal (5) ácido fosfórico, silano e primer (4) ácido fosfórico, adesivo universal; (6) ácido fluorídrico, silano e primer; (7) ácido fluorídrico e adesivo universal; (8) broca, silano e primer e (9) broca e adesivo universal. Em seguida, foi aplicado na superfície de colagem do bráquete metálico (Standart Edgewise para incisivo central superior ­ Morelli, Sorocaba/SP) a resina ortodôntica Transbond XT/3M. O bráquete foi colado na resina composta Filtek Z350 (3M/ESPE). Após 24 horas foram submetidos ao teste de cisalhamento na máquina Instron, com velocidade de 0,5mm/min. Os dados foram submetidos à ANOVA e teste de Tukey. Em seguida foi avaliado o Índice de Remanescente Adesivo (IRA). Não houve diferença significativa entre os agentes de união quanto à resistência de união (p>0,05). Os oito grupos que receberam agentes de união apresentaram resistência significativamente maior do que o grupo controle (p<0,05). O grupo preparado com ácido fluorídrico apresentou menor resistência que os preparados com ácido fosfórico (com silano + primer transbond) e broca diamantada (com silano + primer transbond e com adesivo universal), p<0,05. Concluiu-se que o tratamento de superfície influencia na resistência de união. (AU)


Abstract The aim of this in vitro experimental study was to evaluate the shear bond strength of bracket bonding in different composite resin surface treatments associated with two bonding agents. Ninety specimens were made with Filtek Z350 composite resin (3M/ESPE). The specimens were randomly divided into nine groups (n=10): (1) control group; (2) silane and primer; (3) universal adhesive (5) phosphoric acid, silane and primer (4) phosphoric acid, universal adhesive; (6) hydrofluoric acid, silane and primer; (7) hydrofluoric acid and universal adhesive; (8) drill, silane and primer and (9) universal drill and adhesive. Transbond XT/3M orthodontic resin was then applied to the bonding surface of the metal bracket (Standart Edgewise for upper central incisor ­ Morelli, Sorocaba/SP). The bracket was bonded to the Filtek Z350 composite resin (3M/ ESPE). After 24 hours they were submitted to the shear bond test on the Instron machine at a speed of 0.5mm/min. Data were submitted to ANOVA and Tukey test. Then the Adhesive Remnant Index (ARI) was evaluated. There was no significant difference between bonding agents regarding bond strength (p> 0.05). The eight groups that received bonding agents showed significantly higher resistance than the control group (p <0.05). The group prepared with hydrofluoric acid presented lower resistance than those prepared with phosphoric acid (with silane + transbond primer) and diamond drill (with silane + transbond primer and universal adhesive), p <0.05. It was concluded that the surface treatment influences the bond strength.(AU)


Assuntos
Braquetes Ortodônticos , Resinas Compostas , Resistência ao Cisalhamento
19.
São José dos Campos; s.n; 2022. 55 p. tab, ilus.
Tese em Português | BBO - Odontologia | ID: biblio-1397524

RESUMO

Este estudo avaliou a resistência e a confiabilidade adesiva entre zircônias com diferentes graus de translucidez com o cimento resinoso, sinterizadas de forma convencional e rápida, além de avaliar a susceptibilidade ao envelhecimento térmico dessas interfaces. Espécimes de quatro diferentes zircônias (3YTZP/Translúcida [T], 3Y-TZP/Alta Translucidez [HT], 4Y-PSZ/Super Translúcida [ST] e 5Y-PSZ/Extra Translúcida [XT]) foram obtidos a partir de blocos de CAD/CAM e polidos. Todas as zircônias foram sinterizadas de forma convencional (ciclo de ~12h), entretanto as zircônias T e HT foram subdivididas em grupos também sinterizados na forma rápida (~2h), seguindo o protocolo do fabricante. As superfícies adesivas foram jateadas com Al2O3 50 µm e silanizadas com primer contendo MDP, um cilindro de cimento resinoso foi construído na superfície cerâmica (Ø = 1 mm; h = 2 mm). Metade dos espécimes foram submetidos a termociclagem previamente ao ensaio (6000 ciclos; 5 ­ 55ºC); a outra metade das amostras foi submetida diretamente ao ensaio de microcisalhamento com fio em uma máquina de ensaios universal. Os dados de resistência adesiva foram submetidos a ANOVA 2-fatores e teste de Tukey (95%), bem como à análise de Weibull para determinação da confiabilidade adesiva. A média do valor da resistência adesiva foi estatisticamente diferente entre os materiais, apenas as zircônias HT e ST não foram afetadas negativamente pelo envelhecimento térmico. A forma de sinterização rápida foi estatisticamente semelhante à convencional para a zircônia T, entretanto a HT com sinterização rápida mostrou maior resistência adesiva imediata do que a convencional. O módulo de Weibull foi superior paras zircônias HT convencional e ST. O envelhecimento térmico causa uma degradação das interfaces adesivas das zircônias 3Y-TZP (T) e 5Y-PSZ (XT) com o cimento resinoso, entretanto não afeta as interfaces das zircônias 3Y-TZP (HT) e 4YPSZ (ST). O método de sinterização rápido não altera a resistência de união das zircônias estudadas com o cimento resinoso a longo prazo. A confiabilidade adesiva segundo o módulo de Weibull é superior para a 3Y-TZP (HT convencional) e 4Y-PSZ (ST). (AU)


This study evaluated the adhesive strength and reliability of zirconia with different degrees of translucency with resin cement, sintered in a conventional and speed mode, in addition to evaluating the susceptibility to thermal aging of these interfaces. Specimens of four different zirconia (3Y-TZP/Translucent [T], 3Y-TZP/High Translucent [HT], 4Y-PSZ/Super Translucent [ST] and 5YPSZ/Extra Translucent [XT]) were obtained from CAD/CAM blocks and polished. All zirconia were conventionally sintered (~12h cycle), however the T and HT zirconia were subdivided into groups also sintered in the speed mode (~2h), following the manufacturer's protocol. The adhesive surfaces were sandblasted with 50 µm Al2O3 and silanized with a primer containing MDP, a resin cement cylinder was built on the ceramic surface (Ø = 1 mm; h = 2 mm). Half of the specimens were submitted to thermocycling prior to the assay (6000 cycles; 5 ­ 55ºC); the other half of the samples were directly subjected to the wire microshear test in a universal testing machine. The bond strength data were submitted to 2-way ANOVA and Tukey's test (95%), as well as Weibull analysis to determine the adhesive reliability. The average value of bond strength was statistically different between materials, only HT and ST zirconia were not negatively affected by thermal aging. The speed sintering form was statistically similar to the conventional one for T zirconia, however the speed sintered HT showed higher immediate bond strength than the conventional one. The Weibull modulus was superior for conventional HT and ST zirconia. Thermal aging causes a degradation of the adhesive interfaces of 3Y-TZP (T) and 5Y-PSZ (XT) zirconia with the resin cement, however it does not affect the interfaces of 3Y-TZP (HT) and 4Y-PSZ (ST) zirconia. The speed sintering method does not change the bond strength of the zirconia studied with the resin cement in the long term. Adhesive reliability according to the Weibull module is superior for 3Y-TZP (conventional HT) and 4Y-PSZ (ST). (AU)


Assuntos
Cimentos de Resina , Resistência ao Cisalhamento , Materiais Dentários , Análise de Variância
20.
São José dos Campos; s.n; 2022. 56 p. tab, ilus.
Tese em Português | BBO - Odontologia | ID: biblio-1401286

RESUMO

Objetivo: Avaliar, por meio de um ensaio biomecânico, a resistência ao cisalhamento dos braquetes cerâmicos confeccionados em impressora 3D. Metodologia: Foram testados três tipos distintos de braquetes: Braquetes cerâmicos LightForce Clear® - 3D - LFO System®, (Cambridge, Massac ­ EUA) (n=10), neste trabalho denominado como grupo LFC, braquetes cerâmicos LightForceWhite® - 3D ­ LFO System® - (Cambridge, Massac ­ EUA) (n=10), neste trabalho denominado como grupo LFW, e braquetes cerâmicos Clarity® da 3M® ­ UNITEK (Monrovia, Califórnia ­ EUA) (n=10), neste trabalho denominado como grupo C. Os braquetes do grupo C foram utilizados como controle. Foram colados em esmalte bovino, fixados em suportes para realização de teste em máquina universal de cisalhamento com acessórios de garra para suporte. Foi aplicada uma carga inciso-apical sobre o braquete com célula de carga de 50kgf e velocidade de deslocamento de 1 mm/min até o surgimento de falha na interface dente-braquete. O valor de força de pico registrado foi considerado como a força de cisalhamento (N) necessária para romper a união dente-suporte. A resistência ao cisalhamento foi obtida, em MPa, dividindo a carga de ruptura, em Newtons, pela área da superfície em mm2 . A análise da fratura foi feita com aumento de 15x utilizando microscópio estereoscópio binocular Discovery V20 - Carl Zeiss® (Oberkochen, Alemanha). Análise estatística: Foi realizada análise de variância utilizando teste ANOVA. O teste Tukey foi aplicado para determinar quaisquer diferenças significativas para valores de desempenho entre os grupos. Resultados: Os valores médios e desvio padrão obtidos no ensaio de resistência ao cisalhamento (Mpa) nos três grupos de braquetes foram: 12,00 ± 5,26 para C, 16,45 ± 3,57 para LFC e 14,58 ± 5,04 para LFW. Não houve diferença estatística na resistência ao cisalhamento de nenhum dos grupos testados, os grupos LFC e LFW se mostraram semelhantes ao grupo C (controle). Conclusão: Os braquetes cerâmicos confeccionados em impressora 3D apresentaram resultados satisfatórios de SBS quando comparados ao grupo controle. Todos os grupos apresentaram fratura adesiva semelhante demonstrando boas retenções em suas bases (AU)


Objective: to evaluate the shear strength of ceramic brackets produced in a 3D printer by a biomechanical test. Methodology: Three different types of brackets were tested: LightForce Clear® ceramic brackets - 3D - LFO System®, (Cambridge, Massac - USA) (n=10), referred to as the LFC group in this paper, LightForceWhite® ceramic brackets - 3D - LFO System® - (Cambridge, Massac - USA) (n=10), referred to as the LFW group in this paper, and Clarity® ceramic brackets from 3M® - UNITEK (Monrovia, California - USA) (n=10), referred to as Group C in this paper. Group C brackets were used as controls. They were bonded to bovine enamel and attached to holders for testing in a universal machine with shear claw accessories. The bracket was loaded with a load cell of 50 kgf and a displacement speed of 1 mm/min until failure occurred at the tooth-bracket interface. The peak force recorded was considered to be the shear force (N) required to break the tooth-bracket junction. The shear strength in MPa was determined by dividing the fracture load in Newtons by the area in mm2. Fracture analysis was performed at 15x magnification using a Discovery V20 binocular stereoscopic microscope - Carl Zeiss® (Oberkochen, Germany). Statistical analysis: Analysis of variance was performed using ANOVA test. The Tukey test was applied to determine any significant differences for performance values between groups. Results: The mean values and standard deviation obtained in the shear strength test (Mpa) in the three groups of brackets were: 12.00 ± 5.26 for C, 16.45 ± 3.57 for LFC and 14.58 ± 5.04 for LFW. There was no statistical difference in the shear strength of any of the groups tested, the LFC and LFW groups were similar to group C (control). Conclusion: Ceramic brackets printed on a 3D printer showed satisfactory SBS results when compared to the control group. All groups presented adhesive fracture demonstrating good retention at their bases (AU)


Assuntos
Animais , Bovinos , Análise de Variância , Braquetes Ortodônticos , Esmalte Dentário , Resistência ao Cisalhamento , Impressão Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA