J Craniovertebr Junction Spine ; 14(3): 299-305, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37860022

RESUMO

Placement of pedicle screw in the subaxial cervical spine is a challenging and complex technique but provides significant biomechanical advantages. Despite its potential complications, the role and use of cervical pedicle screw (CPS) are growing. A literature review of the significant articles on applying pedicle screws in the subaxial cervical spine was done (articles between 1994 and 2020). Furthermore, our center´s experience of 15 years related to CPS is also discussed in this study. Transpedicular instrumentation in the subaxial cervical spine requires profound anatomical knowledge and meticulous surgical technique. This technique provides superior biomechanical stability compared to the other cervical fixation techniques. Pull-out strength of CPS is twice as compared to the lateral mass screws. There have been numerous variations in the technique of CPS, varying from open techniques to minimally invasive and the use of biomodels and templates during this procedure. Clinically, CPS can be used in different cervical trauma situations, such as fracture-dislocations, floating lateral mass, and fractures associated with ankylosing spondylitis. Despite the possibility of neurovascular injury due to the proximity of the vertebral artery, spinal cord, and spinal nerves to the cervical pedicles, scientific literature, and our center × s experience show low risk, and this technique can be performed safely. CPS placement is a safe procedure, and it has great potential in the management of cervical spine trauma.

2.
Int. j. morphol ; 41(1): 111-117, feb. 2023. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1430506

RESUMO

SUMMARY: Anatomical variation of the foramina transversaria (FT) is associated with vertebral neurovascular symptoms and can cause complications after lower spine surgery, especially cervical pedicle screw (CPS) insertion. FT variation has been documented and classified in various populations, as this information can help increase cervical stability in subaxial vertebral surgery. Although the morphometry of the upper cervical spine in Thai populations has been reported, there have yet been no studies examining the features of FT. The FT of dried cervical spines (C3-C7; left and right side; n = 107, male = 53 and female = 54) were examined for morphological variation, and their anteroposterior (AP) and transverse (T) diameters were measured using a digital vernier caliper. Morphometric data and variations were compared by sex and lateral side. It was that the C3-C6 FT in both sexes were round, and the C7 FT was elliptical with an oblique right side. FT diameters did not differ significantly by sex except for the AP diameters of C6-C7 and for T diameters of C4 and C7. The left AP diameters of C3-C6 were significantly longer than the right, as were the T diameters of C4 and C7 FT. Additionally, T diameter was significantly longer than that of the AP, except that of the left C6 in male spines, which did not differ from the AP. Most FT examined were round. These findings should be considered in the provisional diagnosis of vertebral neurovascular symptoms caused by FT variation as well as that of neurovascular damage after cervical pedicle screw placement.


La variación anatómica del foramen transverso (FT) se asocia con síntomas neurovasculares vertebrales y puede causar complicaciones después de la cirugía de columna cervical inferior, especialmente la inserción de tornillos pediculares cervicales (TPC). La variación del FT se ha documentado y clasificado en varias poblaciones, ya que esta información puede ayudar a aumentar la estabilidad cervical en la cirugía vertebral subaxial. Aunque se ha informado sobre la morfometría de la columna cervical superior en poblaciones tailandesas, aún no se han realizado estudios que examinen las características de FT. Se examinó la variación morfológica del FT de vértebras cervicales secas (C3-C7; lado izquierdo y derecho; n = 107, hombres = 53 y mujeres = 54), y se midieron sus diámetros anteroposterior (AP) y transverso (T) usando un pie de metro digital. Se compararon datos morfométricos y variaciones por sexo y lado. Los FT de C3-a C6 en ambos sexos eran redondos, y el FT C7 era elíptico con el lado derecho oblicuo. Los diámetros del FT no difirieron significativamente por sexo excepto para los diámetros AP de C6- C7 y para los diámetros transversos de C4 y C7. Los diámetros AP izquierdos de C3-C6 eran significativamente más largos que los del lado derecho, al igual que los diámetros transversos de C4 y C7. Además, el diámetro transverso fue significativamente mayor que el AP, excepto el C6 izquierdo en las vértebras de hombres, que no difirió del AP. La mayoría de los FT examinados eran redondos. Estos hallazgos deben ser considerados en el diagnóstico provisional de síntomas neurovasculares vertebrales causados por la variación del FT, así como en el de daño neurovascular tras la colocación de tornillos pediculares cervicales.


Assuntos
Humanos , Masculino , Feminino , Vértebras Cervicais/anatomia & histologia , Variação Anatômica , Tailândia , Caracteres Sexuais