Rev. cuba. oftalmol ; 26(3): 399-409, sep.-dic. 2013.
Artigo em Espanhol | LILACS | ID: lil-706671

RESUMO

Objetivo: caracterizar el comportamiento del cálculo de la lente intraocular mediante biometría ultrasónica. Métodos: se realizó un estudio descriptivo y prospectivo, con un grupo de pacientes atendidos por el Servicio de Catarata del Centro Oftalmológico Enrique Cabrera, que recibieron tratamiento quirúrgico por catarata con implante de lente intraocular, mediante técnica de Blumenthal. La muestra se conformó con 160 ojos y se estudiaron las variables: sorpresa refractiva, edad, longitud axial y promedio queratométrico según resultado refractivo, poder dióptrico de la lente y componente esférico según edad. Resultados: como resultados más sobresalientes, se obtuvo que el 78,7 por ciento no presentó error en el cálculo de la lente, la mayoría de los pacientes tenían 60 años y más, predominó el rango de longitud axial entre 22 y 24,4 (67,5 por ciento), el promedio queratométrico de 43 a 44,99 (64,3 por ciento), el poder dióptrico del lente de + 20 a + 23 dioptrías (48,2 por ciento) y el componente esférico entre 0,00 y +/-1,00 dioptrías (78,8 por ciento). Conclusiones: se considera que la biometría ultrasónica resulta adecuada para el cálculo correcto del lente


Objective: to characterize the behavior of the intraocular lens calculation through ultrasound biometrics. Methods: a prospective and descriptive study was conducted in a group of patients whose cataract was surgically treated with intraocular lens implantation by means of Blumental technique at the cataract service of Enrique Cabrera ophthalmological center. The sample was made up of 160 eyes. The studied variables included refractive surprise, age, axial length and keratometric average according to refractive result, dioptric power of the lens and spheral component by age. Results: the main results were 78.7 percent of patients did not present lens power calculation errors, most of them were 60 years-old and over, the axial length range of 22 to 24.4(67.5 percent) prevailed, the keratometric average was 43 to 44.9 (64.3 percent), the dioptric power of the lens ranged +20 to +23 dioptries (48.2 percent) and the spheral component yielded 0.00 and+/ - 1.00 dioptries (78.8 percent). Conclusions: it is considered that ultrasound biometrics is suitable for a correct lens calculation


Assuntos
Humanos , Biometria/métodos , Extração de Catarata/métodos , Implante de Lente Intraocular/métodos , Ultrassonografia , Epidemiologia Descritiva , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA