Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Acta Ortop Bras ; 32(3): e269705, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39119246

RESUMO

Objective: Tibial plateau fractures are common intra-articular fractures that pose classification and treatment challenges for orthopedic surgeons. Objective: This study examines the value of 3D printing for classifying and planning surgery for complex tibial plateau fractures. Methods: We reviewed 54 complex tibial plateau fractures treated at our hospital from January 2017 to January 2019. Patients underwent preoperative spiral CT scans, with DICOM data processed using Mimics software. 3D printing technology created accurate 1:1 scale models of the fractures. These models helped subdivide the fractures into seven types based on the tibial plateau's geometric planes. Surgical approaches and simulated operations, including fracture reduction and plate placement, were planned using these models. Results: The 3D models accurately depicted the direction and extent of fracture displacement and plateau collapse. They facilitated the preoperative planning, allowing for precise reconstruction strategies and matching intraoperative details with the pre-printed models. Post-surgery, the anatomical structure of the tibial plateau was significantly improved in all 54 cases. Conclusion: 3D printing effectively aids in the classification and preoperative planning of complex tibial plateau fractures, enhancing surgical outcomes and anatomical restoration. Level of Evidence IV, Prospective Study.


Objetivo: As fraturas do planalto tibial são fraturas intra-articulares comuns de classificação e tratamento desafiadores aos cirurgiões ortopédicos. Objetivo: Este estudo investiga o uso de impressão 3D para classificar e planejar a cirurgia de fraturas complexas do planalto tibial. Métodos: 54 fraturas complexas do planalto tibial tratadas em nosso hospital de janeiro de 2017 a janeiro de 2019 foram revisadas. Os pacientes foram submetidos a tomografias computadorizadas em espiral pré-operatórias, com dados DICOM processados usando o software Mimics. A tecnologia de impressão 3D gerou modelos precisos em escala 1:1 das fraturas. Estes modelos ajudaram a subdividir as fraturas em sete tipos com base nos planos geométricos do planalto tibial. As abordagens cirúrgicas e as operações simuladas, incluindo a redução da fratura e a colocação de placa, foram planejadas utilizando estes modelos. Resultados: Os modelos 3D representaram com precisão a direção e a extensão da deslocação da fratura e do colapso do planalto. Os modelos facilitaram o planejamento pré-operatório, viabilizando estratégias de reconstrução precisas e a correspondência dos detalhes intraoperatórios com os modelos pré-impressos. Após a cirurgia, a estrutura anatômica do planalto tibial melhorou significativamente em todos os 54 casos. Conclusão: A impressão 3D ajuda na classificação e no planejamento pré-operatório de fraturas complexas do planalto tibial, melhorando os resultados cirúrgicos e a restauração anatômica. Nível de Evidência IV, Estudo Prospectivo.

2.
Acta ortop. bras ; Acta ortop. bras;32(3): e269705, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1568749

RESUMO

ABSTRACT Objective: Tibial plateau fractures are common intra-articular fractures that pose classification and treatment challenges for orthopedic surgeons. Objective: This study examines the value of 3D printing for classifying and planning surgery for complex tibial plateau fractures. Methods: We reviewed 54 complex tibial plateau fractures treated at our hospital from January 2017 to January 2019. Patients underwent preoperative spiral CT scans, with DICOM data processed using Mimics software. 3D printing technology created accurate 1:1 scale models of the fractures. These models helped subdivide the fractures into seven types based on the tibial plateau's geometric planes. Surgical approaches and simulated operations, including fracture reduction and plate placement, were planned using these models. Results: The 3D models accurately depicted the direction and extent of fracture displacement and plateau collapse. They facilitated the preoperative planning, allowing for precise reconstruction strategies and matching intraoperative details with the pre-printed models. Post-surgery, the anatomical structure of the tibial plateau was significantly improved in all 54 cases. Conclusion: 3D printing effectively aids in the classification and preoperative planning of complex tibial plateau fractures, enhancing surgical outcomes and anatomical restoration. Level of Evidence IV, Prospective Study.


RESUMO Objetivo: As fraturas do planalto tibial são fraturas intra-articulares comuns de classificação e tratamento desafiadores aos cirurgiões ortopédicos. Objetivo: Este estudo investiga o uso de impressão 3D para classificar e planejar a cirurgia de fraturas complexas do planalto tibial. Métodos: 54 fraturas complexas do planalto tibial tratadas em nosso hospital de janeiro de 2017 a janeiro de 2019 foram revisadas. Os pacientes foram submetidos a tomografias computadorizadas em espiral pré-operatórias, com dados DICOM processados usando o software Mimics. A tecnologia de impressão 3D gerou modelos precisos em escala 1:1 das fraturas. Estes modelos ajudaram a subdividir as fraturas em sete tipos com base nos planos geométricos do planalto tibial. As abordagens cirúrgicas e as operações simuladas, incluindo a redução da fratura e a colocação de placa, foram planejadas utilizando estes modelos. Resultados: Os modelos 3D representaram com precisão a direção e a extensão da deslocação da fratura e do colapso do planalto. Os modelos facilitaram o planejamento pré-operatório, viabilizando estratégias de reconstrução precisas e a correspondência dos detalhes intraoperatórios com os modelos pré-impressos. Após a cirurgia, a estrutura anatômica do planalto tibial melhorou significativamente em todos os 54 casos. Conclusão: A impressão 3D ajuda na classificação e no planejamento pré-operatório de fraturas complexas do planalto tibial, melhorando os resultados cirúrgicos e a restauração anatômica. Nível de Evidência IV, Estudo Prospectivo.

3.
J. oral res. (Impresa) ; 12(1): 195-203, abr. 4, 2023. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1516516

RESUMO

Aim: Correct orientation of the occlusal plane plays a vital role in achieving the perfect occlusal balance and function of complete dentures. This study aimed to evaluate the most reliable posterior reference point of the ala-tragus line (ATL) concerning occlusal plane (OP) in a sample of the dentate Sudanese population. Materials and Methods: A total of 150 subjects with healthy and well-aligned permanent teeth were randomly selected. Right lateral profile photographs were taken with subjects having a fox plane placed intra-orally, contacting the occlusal plane. Reference points corresponding to inferior, middle, and superior borders of the tragus and inferior border of the ala of the nose were marked on photographs. The angles between the lines were measured using the Auto-CAD software program, and the most parallel relationship was determined. Descriptive statistics in terms of means and standard deviations were presented. Independent t-test and one-way ANOVA tests were used to compare as appropriate. A p-value < 0.05 was considered significant. Results: The mean angle formed by the OP and ATL was 8.5±3.69º for the superior level, 4.68±3.13º for the middle line, and 2.89±2.57º for the inferior line. A significant difference was found between the means of the three angles (p< 0.001), while no significant difference (p> 0.05) was found between both genders regarding the measured angles. Conclusions: The line joining the inferior border of the ala of the nose with the inferior border of the tragus of the ear was the most reliable line in terms of parallelism to determine the occlusal plane orientation.


Antecedentes: La orientación correcta del plano oclusal juega un papel vital para lograr el equilibrio oclusal perfecto y la función de las prótesis completas. Este estudio tuvo como objetivo evaluar el punto de referencia posterior más confiable de la línea ala-trago (ATL) con respecto al plano oclusal (OP) en una muestra de la población dentada de Sudán. Materiales y Métodos: Se seleccionaron aleatoriamente un total de 150 sujetos con dientes permanentes sanos y bien alineados. Se tomaron fotografías de perfil lateral derecho de sujetos a los que se les colocó un plano de zorro intraoralmente, en contacto con el plano oclusal. En las fotografías se marcaron los puntos de referencia correspondientes a los bordes inferior, medio y superior del trago y al borde inferior del ala de la nariz. Los ángulos entre las líneas se midieron utilizando el programa de software Auto-CAD y se determinó la relación más paralela. Se presentaron estadísticas descriptivas en términos de medias y desviaciones estándar. Se utilizaron prueba-t independiente y prueba ANOVA unidireccional para las comparaciones, según correspondiera. Se consideró significativo un valor de p<0,05. Resultados: El ángulo medio formado por OP y ATL fue de 8,5±3,69º para el nivel superior, 4,68±3,13º para la línea media y 2,89±2,57º para la línea inferior. Se encontró una diferencia significativa entre las medias de los tres ángulos (p< 0,001), mientras que no se encontró diferencia significativa (p>0,05) entre ambos sexos con respecto a los ángulos medidos. Conclusión: La línea que une el borde inferior del ala de la nariz con el borde inferior del trago de la oreja fue la línea más confiable en términos de paralelismo para determinar la orientación del plano oclusal.


Assuntos
Masculino , Feminino , Adolescente , Adulto , Adulto Jovem , Pontos de Referência Anatômicos , Prostodontia , Sudão , Cefalometria , Estudos Transversais , Prótese Total
4.
Forensic Sci Res ; 8(3): 211-218, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38221974

RESUMO

The establishment of anthropometric measurements is of fundamental importance for the correct identification of human bodies. The objective of this study was to evaluate the accuracy and reliability of two-dimensional craniometric landmarks obtained from three-dimensional cone beam computed tomography reconstructions for forensic identification of humans. Computed tomography images with voxel sizes of 0.25, 0.3, and 0.4 mm were obtained using i-CAT® three-dimensional equipment. Ten landmarks were randomly selected, and 10 measurements were demarcated in the three-dimensional reconstruction to evaluate the mandibular condyle, ramus, and body. This study demonstrated that protocols with voxels of 0.3 mm should be preferentially indicated for the evaluation of linear and angular measurements. Implementing our methodology using prototypes for clinical and forensic simulations allows comparisons with human databases in identification issues.

5.
Acta Paul. Enferm. (Online) ; 36: eAPE00662, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS, BDENF - Enfermagem | ID: biblio-1439045

RESUMO

Resumo Objetivo Sumarizar as evidências científicas sobre os marcos anatômicos, na radiografia, utilizados para avaliar a ponta distal do cateter central de inserção periférica em recém-nascidos. Métodos Trata-se de uma revisão integrativa da literatura realizada nas bases de dados Web of Science, National Library of Medicine (PubMed/MEDLINE) e Scopus, entre os anos de 2017 e 2021. Resultados Dos 263 documentos encontrados nas bases, 13 preencheram os critérios de elegibilidade e foram selecionados para análise. Destes, 12 eram estudos observacionais e um experimental. Quanto ao país de origem, apenas um estudo foi publicado no Brasil, cinco na China, dois nos Estados Unidos da América e um estudo na Itália, Alemanha, Canadá, Irã e Índia. As evidências encontradas demonstraram a existência de sete marcos anatômicos utilizados na radiografia para visualização da ponta do cateter percutâneo em neonatos, sendo a unidade vertebral o referencial norteador predominante. Conclusão Para cateteres inseridos em membros superiores, os marcos anatômicos que mais se aproximam da junção cavo-atrial são a quinta e sétima vértebra torácica, ou duas unidades vertebrais abaixo da carina. Para os membros inferiores, o posicionamento da ponta do cateter deve estar entre a nona e décima vértebra torácica ou acima da quarta vértebra lombar.


Resumen Objetivo Sintetizar las evidencias científicas sobre los puntos anatómicos, en radiografías, utilizados para evaluar el extremo distal del catéter central de inserción periférica en recién nacidos. Métodos Se trata de una revisión integradora de la literatura realizada en las bases de datos Web of Science, National Library of Medicine (PubMed/MEDLINE) y Scopus, entre los años 2017 y 2021. Resultados De los 263 documentos encontrados en las bases, 13 cumplieron con los criterios de elegibilidad y fueron seleccionados para análisis. Entre ellos, 12 eran estudios de observación y uno era experimental. Con relación al país de origen, únicamente un estudio fue publicado en Brasil, cinco en China, dos en Estados Unidos de América y un estudio en Italia, Alemania, Canadá, Irán e India. Las evidencias encontradas demostraron la existencia de siete puntos anatómicos utilizados en la radiografía para la visualización de la extremidad del catéter percutáneo en neonatos, y la unidad vertebral fue el referente orientador predominante. Conclusión Para catéteres insertados en miembros superiores, los puntos anatómicos que más se aproximaron a la unión cavoatrial son la quinta y la séptima vértebra torácica o dos unidades vertebrales por debajo de la carina. Para los miembros inferiores, la ubicación de la extremidad del catéter debe estar entre la novena y la décima vértebra torácica o sobre la cuarta vértebra lumbar.


Abstract Objective To summarize the scientific evidence on anatomical landmarks on radiography used to evaluate the distal tip of the peripherally inserted central catheter in newborns. Methods This is an integrative literature review performed between 2017 and 2021 in Web of Science, National Library of Medicine (PubMed/MEDLINE) and Scopus databases. Results Thirteen out of 263 documents found in the databases met the eligibility criteria and were selected for analysis. Of these, 12 were observational studies and one was experimental. As for the country of origin, only one study was published in Brazil, five in China, two in the United States of America; and Italy, Germany, Canada, Iran and India with one study each. The evidence found demonstrated the existence of seven anatomical landmarks used in radiography to visualize the tip of the percutaneous catheter in newborns, and the vertebral body as the predominant guiding reference. Conclusion For catheters inserted in the upper limbs, the anatomical landmarks closer to the cavo-atrial junction are the fifth and seventh thoracic vertebrae, or two vertebral bodies below the level of the carina. For the lower limbs, the catheter tip should be positioned between the ninth and tenth thoracic vertebrae or above the fourth lumbar vertebra.

6.
World Neurosurg ; 167: e475-e506, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35970294

RESUMO

OBJECTIVE: To evaluate the relationship between the oculomotor nerve (CNIII) and the internal carotid artery (ICA) as a new anatomic-radiologic landmark for distinguishing the exact location of a paraclinoid intracranial aneurysm (IA). METHODS: Microanatomic dissections were performed in 20 cavernous sinuses to evaluate the ICA paraclinoid region. Based on anatomic observations, a new magnetic resonance (MRI) protocol to classify paraclinoid aneurysms was proposed. MRI of 42 IAs from 34 patients was independently analyzed and classified as intracavernous, extracavernous, or transitional by 2 neuroradiologists. To validate the proposed MRI protocol, each IA was classified by a three-dimensionally (3D) printed biomodel and agreement with the radiologic classifications was evaluated. Of 42 IAs, 23 undergoing microsurgeries were also classified by direct visualization. RESULTS: We observed that the true cavernous sinus roof is defined by the carotid-oculomotor membrane, which has an intimate relationship with the intersection between the superior limit of the CNIII and the ICA. Based on this intersection, all 42 IAs were radiologically classified and agreement with the 3D printed biomodels was observed in 95% IAs. Concordance tests showed a statistically significant (P < 0.05) agreement between the classifications. All 23 IAs treated had the radiologic and 3D biomodel classification confirmed. CONCLUSIONS: The intersection between the ICA and the CNIII, which crosses it transversely in its entire diameter, is a reliable anatomic-radiologic landmark to correctly classify paraclinoid aneurysms. Through a new MRI protocol, it is possible to radiologically identify this intersection and to easily distinguish the intracavernous and extracavernous ICA paraclinoid aneurysms.


Assuntos
Doenças das Artérias Carótidas , Aneurisma Intracraniano , Humanos , Artéria Carótida Interna/cirurgia , Nervo Oculomotor/diagnóstico por imagem , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/patologia , Imageamento por Ressonância Magnética/métodos , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/cirurgia , Doenças das Artérias Carótidas/patologia , Impressão Tridimensional
7.
Coluna/Columna ; 21(2): e263305, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1384654

RESUMO

ABSTRACT Objective: Rate and compare radiographic measurements of thoracic kyphosis and lumbar lordosis using anatomical and dynamic parameters. Methods: Measurements were performed on lateral radiographs of 10 adults of both sexes without spinal disease or deformity. Thoracic kyphosis and lumbar lordosis were measured using anatomical parameters (T1-T12, T4-T12, T5-T12 and L1-S1) or dynamic parameters (cervicothoracic or thoracolumbar inflection point). Results: Thoracic kyphosis and lumbar lordosis were different in 30% of subjects. Differences in thoracic kyphosis values were observed according to the anatomical reference used for measurement. Lumbar lordosis wasn`t statistical difference considering the anatomical or dynamic reference, but in 30% of the individuals the inflection point was different from the anatomical reference. Conclusions: Thoracic kyphosis and lumbar lordosis values differ according to anatomical and dynamic references. The reference used must be considered in the measurement and interpretation of values. Level of evidence IV; Case series.


RESUMO: Objetivo: Avaliar e comparar as mensurações radiográficas da cifose torácica e lordose lombar utilizando parâmetros anatômicos e dinâmicos. Métodos: As mensurações foram realizadas nas radiografias em perfil de 10 adultos de ambos os sexos sem doença ou deformidade da coluna vertebral. A cifose torácica e a lordose lombar foram mensuradas utilizando parâmetros anatômicos (T1-T12,T4-T12, T5-T12 e L1-S1) ou dinâmicos (ponto de inflexão cervicotorácico ou toracolombar) Resultados: As referências anatômicas e dinâmicas para a identificação da cifose torácica e lordose lombar foram diferentes em 30% dos indivíduos. Foi observado diferença dos valores da cifose torácica de acordo com a referência anatômica utilizada para a mensuração. A lordose lombar não apresentou diferença estatística considerando a referência anatômica ou dinâmica, mas em 30% dos indivíduos o ponto de inflexão era diferente da referência anatômica. Conclusões: Os valores da cifose torácica e lordose lombar apresentam diferenças de acordo com as referências anatômicas e dinâmicas. A referência utilizada deve ser considerada na mensuração e interpretação dos valores. Nível de evidência IV; Série de casos.


RESUMEN: Objetivo: Calificar y comparar medidas radiográficas de cifosis torácica y lordosis lumbar utilizando parámetros anatómicos y dinámicos. Métodos: Las mediciones se realizaron en radiografías laterales de 10 adultos de ambos sexos sin enfermedad o deformidad de la columna. La cifosis torácica y la lordosis lumbar se midieron mediante parámetros anatómicos (T1-T12, T4-T12, T5-T12 y L1-S1) o dinámicos (punto de inflexión cervicotorácico o toracolumbar). Resultados: La cifosis torácica y la lordosis lumbar fueron diferentes en el 30% de los sujetos. Se observaron diferencias en los valores de cifosis torácica según la referencia anatómica utilizada para la medición. La lordosis lumbar no fue diferencia estadística considerando la referencia anatómica o dinámica, pero en el 30% de los individuos el punto de inflexión fue diferente de la referencia anatómica. Conclusiones: Los valores de cifosis torácica y lordosis lumbar difieren según referencias anatómicas y dinámicas. La referencia utilizada debe ser considerada en la medición e interpretación de los valores. Nivel de evidencia IV; Series de casos.


Assuntos
Humanos , Adulto , Ortopedia
8.
Int. j. odontostomatol. (Print) ; 15(2): 397-402, jun. 2021. tab, ilus
Artigo em Espanhol | LILACS | ID: biblio-1385776

RESUMO

La Dimensión Vertical Oclusal, es la distancia entre un punto anatómico fijo en el maxilar y otro sobre la parte móvil de la mandíbula cuando los órganos dentarios están en contacto oclusal. La obtención de este registro determina el espacio vertical necesario para la rehabilitación de los pacientes. En la actualidad existen distintos métodos para el registro de la Dimensión Vertical Oclusal, en este estudio se analizaron: Métodos fisiológicos y métodos mecánicos. El objetivo fue realizar una revisión sistemática, sobre los métodos de registro, para determinar la Dimensión Vertical Oclusal en pacientes dentados. Se recopiló información científica desde Mayo 2019 hasta Julio 2020 en diferentes bases de datos electrónicas, encontrando un tota l de 13948 artículos, después de eliminar artículos repetidos, por título, por resumen y por metodología PICO se seleccionaron un total de 24 artículos para su análisis y clasificación. Más de un autor menciona que no existe un método unirversalmente aceptado o exacto para determinar la Dimensión Vertical Oclusal. Se sugiere la combinación de varios métodos de registro de Dimensión Vertical Oclusal, se debe de considerar la manera más adecuada para lograr un registro más acertado.


Occlusal Vertical Dimension is the distance between an anatomical point in the maxilla and another on the mobile part of the mandible when the teeth are in occlusal contact. Obtaining this record determines the vertical space necessary for the rehabilitation of patients. Nowadays there are different methods for the record of the Occlusal Vertical Dimension, in this study the following were analyzed: physiological methods and mechanical methods. The objective was to do a systematic review of the registration methods to determine the Occlusal Vertical Dimension in dentate patients. Scientific information was collected from May 2019 to July 2020 in different electronic databases, finding a total of 13,948 articles, after eliminating repeated articles, by title, by abstract and by PICO methodology, a total of 24 articles were selected for analysis and classification. More than one author mentions that there is no universally accepted or exact method for determining Occlusal Vertical Dimension. A combination of several methods of Occlusal Vertical Dimension registration is suggested; it should be considered the most appropriate way to achieve a more accurate registration.


Assuntos
Humanos , Oclusão Dentária , Mandíbula , Prostodontia , Dimensão Vertical , Prática Clínica Baseada em Evidências
9.
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1135515

RESUMO

Abstract Objective: To assess the effect of experience in landmark identification on two-dimensional (2D) lateral cephalograms on performance of dental students concerning landmark identification on three-dimensional (3D) cone-beam computed tomography (CBCT) scans. Material and Methods: This quasi-experimental study evaluated 40 dental students in two groups (n=20). Group 1 included senior dental students who had experience in landmark identification on 2D lateral cephalograms and Group 2 included third-year dental students with no such experience. Both groups received instructions on identification of eight landmarks on 3D CBCT scans. The coordinates of the landmarks were determined in x, y and z axes. One orthodontist determined the mean coordinates of each landmark as a reference by twice measurements with a one-week interval. The mean distance from the identified points to the reference points was reported as the mean consistency (MC), and the standard deviation of the mean was considered as precision of landmark identification. Data were analyzed using independent samples t-test. Results: The mean distances from the points identified as nasion, point B, orbitale, anterior nasal spine (ANS), menton, coronoid process and pogonion in x, y and z axes and point A in x and z axes (p<0.001) to the reference points in Group 1 were greater than those in Group 2 with no such experience. Conclusion: Previous experience in landmark identification on 2D cephalograms does not help in landmark identification on 3D CBCT scans and may even adversely affect the results.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Estudantes de Odontologia , Educação em Odontologia , Tomografia Computadorizada de Feixe Cônico , Ortodontistas , Cefalometria/instrumentação , Estatísticas não Paramétricas , Irã (Geográfico)/epidemiologia
10.
J Back Musculoskelet Rehabil ; 30(4): 735-744, 2017 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-28453451

RESUMO

BACKGROUND: Evidence on the diagnostic performance of palpatory methods and possible confounding factors is scarce. OBJECTIVES: To examine the sensitivity of palpatory methods for location of lumbopelvic landmarks and to assess its association with personal characteristics. METHODS: Eighty-three participants (41 men, 55.6 (16.5) years, 25.9 (4.8) kg/m2 [mean (SD)]) were enrolled in this single-blinded study. Fourteen body and softy-tissue landmarks were sequentially palpated from the spinous process of L4 to the ischial tuberosity. CT-scan images were used to assess what landmark was located. RESULTS: Sensitivity for location was in range 22-86% for soft-tissues and 26-69% for bony landmarks. Reduction in sensitivity was observed from the quadratus lumborum to the inferior and lateral angle of the sacrum (86-26% and 75-33%, left and right sides, respectively). Palpations of L4 and L5 spinous processes were systematically more cephalic than other landmarks. Gender was weakly correlated to almost all landmarks (rp⁢b= 0.333 or weaker). Body mass index was weakly correlated to the accurate location of ILAS and quadratus lumborum, great trochanter, PSIS, and piriformis (rp⁢b=-0.307 or weaker). CONCLUSIONS: Systematic and propagation errors were present using sequential palpatory methods. Palpation in men was more sensitive and higher BMI was associated with lower sensitivity for lumbopelvic landmarks.


Assuntos
Pontos de Referência Anatômicos , Região Lombossacral , Palpação/métodos , Adulto , Idoso , Estatura , Índice de Massa Corporal , Peso Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Palpação/estatística & dados numéricos , Sacro , Método Simples-Cego , Tomografia Computadorizada por Raios X
11.
Coluna/Columna ; 14(4): 317-319, Oct.-Dec. 2015. graf
Artigo em Inglês | LILACS | ID: lil-770238

RESUMO

Microsurgical landmarks of the facet joint complex were defined to provide guidance and security within the tubular retractor during transforaminal surgery. A retrospective observational study was performed in segments L4-L5 by the left side approach. Microsurgical relevant photos, anatomical models and drawing were used to expose the suggested landmarks. The MI-TLIF technique has advantages compared with conventional open TLIF technique, however minimally invasive technique implies lack of security for the surgeon due to the lack of defined microanatomical landmarks compared to open spine surgery, and disorientation within the tubular retractor, the reason why to have precise microsurgical references and its recognition within the surgical field provide speed and safety when performing minimally invasive technique.


Foram definidas referências anatômicas microcirúrgicas do complexo facetário para obter orientação e segurança no interior do retrator tubular durante a cirurgia transforaminal. Realizou-se um estudo observacional retrospectivo dos procedimentos MI-TLIF nos segmentos L4-L5 com acesso lateral esquerdo. Foram empregados fotos microcirúrgicas relevantes, modelo anatômico e esquemas para expor as referências sugeridas. A técnica de MI-TLIF tem vantagens quando comparada com a técnica TLIF a céu aberto convencional, no entanto, a técnica minimamente invasiva implica falta de segurança para o cirurgião, devido à ausência de referências microanatômicas definidas em comparação com a cirurgia a céu aberto, além de falta de orientação no interior do retrator tubular. Por isso, ter referências microcirúrgicas precisas e seu reconhecimento dentro do campo cirúrgico proporciona rapidez e segurança ao realizar a técnica minimamente invasiva.


Se definieron las referencias anatómicas microquirúrgicas del complejo facetario para aportar orientación y seguridad dentro del portal tubular durante la cirugía transforaminal. Se realizó un estudio observacional retrospectivo de procedimientos MI-TLIF en segmentos L4-L5 abordados del lado izquierdo. Se utilizaron fotos microquirúrgicas relevantes, modelo anatómico y esquemas para exponer las referencias anatómicas sugeridas. La técnica de MI-TLIF tiene ventajas comparada con la técnica abierta convencional de TLIF, sin embargo la técnica mínimamente invasiva confiere falta de seguridad para el cirujano debido a la carencia de referencias microanatómicas definidas comparado con la cirugía abierta y desorientación dentro del acceso tubular por lo que tener referencias microquirúrgicas precisas y su reconocimiento dentro del campo quirúrgico aportan rapidez y seguridad al realizar la técnica mínimamente invasiva.


Assuntos
Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Fusão Vertebral , Pontos de Referência Anatômicos , Vértebras Lombares
12.
Braz. dent. j ; Braz. dent. j;26(3): 297-302, May-Jun/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-751856

RESUMO

The aim of this study was to measure and compare the dimensions of the dental arches on three-dimensional digital study models in children with and without cleft lip and palate before the primary surgery. The sample consisted of 223 digital models of children aged 3-9 months, divided into 5 groups: without craniofacial deformities, unilateral and bilateral incomplete cleft lip and alveolus, unilateral and bilateral complete cleft lip and alveolus, unilateral cleft lip and palate, and bilateral cleft lip and palate. Dental casts of the maxillary dental arches of the children were used. The dental casts underwent a process of scanning through 3D scanner and the measurements used for the correlation among groups were made on the scanned images. Statistical analysis was performed by t test and ANOVA followed by Tukey test. The results showed that the intercanine distance and anterior cleft width was wider in children with unilateral cleft lip and palate. The intertuberosity distances and posterior cleft width was wider in children with bilateral cleft lip and palate among the groups. Children with cleft lip and palate before the primary surgery had wider maxillary arch dimensions than the children without cleft lip and palate.


O propósito deste trabalho foi mensurar e comparar as dimensões dos arcos dentários em modelos digitais tridimensionais de crianças com ou sem fissuras de lábio e palato antes das cirurgias primárias. A amostra foi composta de 223 modelos de gesso de crianças, de 3 a 9 meses, divididas em 5 grupos: sem deformidades craniofaciais, fissura pré-forame incompleta, fissura pré-forame completa, fissura transforame unilateral e fissura transforame bilateral. Modelos de gesso dos arcos dentários superiores das crianças foram utilizados para avaliação. Os modelos passaram por um processo de digitalização, por meio de escâner 3D e as medidas utilizadas para a correlação entre os grupos foram realizadas diretamente nas imagens escaneadas. A análise estatística foi realizada por meio do teste t e ANOVA seguido pelo teste de Tukey. Os resultados mostraram que a distância intercaninos e a amplitude anterior da fissura foram maiores nas crianças com fissura transforame unilateral. A distância intertuberosidades e a amplitude posterior da fissura foi maior nas com fissura transforame bilateral entre os grupos estudados. As crianças com fissura de lábio e palato apresentam as dimensões dos arcos maxilares maiores que as crianças sem fissura labiopalatina antes das cirurgias primárias.


Assuntos
Humanos , Masculino , Feminino , Lactente , Fenda Labial/patologia , Fissura Palatina/patologia , Arco Dental/anatomia & histologia , Reprodutibilidade dos Testes
13.
Braz. dent. sci ; 17(4): 74-81, 2014. tab
Artigo em Inglês | LILACS | ID: lil-742514

RESUMO

Objective: Mandibular foramen (MF) is located on the internal surface of the ramus through which blood vessels and nerves pass. Determination of the anatomic position of the MF is very important in inferior alveolar nerve block anesthesia (IANBA), ramus osteotomy and surgical procedures of the posterior angle of mandibular ramus. The aim of this study was to determine anatomic position of the MF using anatomic landmarks on the three dimensional CBCT images. Material and Methods: A total of 103 CBCT images was evaluated. The NNT Viewer software program was used to measure the distances between the lines tangent on the MF periphery and the anterior border of the ramus, the posterior border of the ramus, the inferior border of the mandible, and the coronoid notch in mm by to age and gender. Results: The results showed a slight difference in anatomic dimensions between the right and left sides, with no significant differences. The anatomic dimensions of the MF on both sides were a little bigger in males than in females. There were no significant differences in the anatomic dimensions of superior inferior and anterior-posterior dimensions of the left and right sides in different age groups. Conclusion: No significant changes occur in the position of the MF with age. The anatomic differences between males and females should be taken into account during IANBA procedures. Males have bigger jaws than females; therefore, there is a longer distance between the MF and the anatomic landmarks evaluated...


Objetivo: O forame mandibular (FM) localiza-se na superfície interna do ramo mandíbula, onde passam vasos sanguíneos e nervos. A determinação da posição anatômica do FM é muito importante para anestesia por bloqueio do nervo alveolar inferior (ABNAI), durante osteotomiano ramo da mandíbula e para procedimentos cirúrgicos do ângulo posterior do ramo mandibular. O objetivo deste estudo foi determinar a posição anatômica do FM utilizando referências anatômicas em imagens tridimensionais de CBCT. Material e Métodos: Um total de 103 imagens de CBCTforam avaliadas. O programa de software NNT Viewer foi utilizado para medir as distâncias em milímetros entre as linhas tangentes na periferia do FM e borda anterior do ramo, borda posterior do ramo, borda inferior da mandíbula e processo coronóide, em relação à idade e o gênero. Resultados: Os resultados mostraram uma ligeira diferença de dimensões anatômicas entre os lados direito e esquerdo, sem diferenças significativas. As dimensões anatômicas do FM em ambos os lados foram um pouco maior no sexo masculino do que no feminino. Não houve diferenças significativas nas dimensões anatômicas superior-inferior e ânteroposterior, tanto do lado direito quanto esquerdo,em diferentes faixas etárias. Conclusão: Mudanças significativas na posição do FM não são observadas em função da faixa etária. As diferenças anatômicas entre homens e mulheres devem ser levadas em consideração durante procedimento ABNAI. Mandíbulas maiores são encontradas no gênero masculino, portanto, há uma maior distância entre o FM e as referências anatômicas avaliadas...


Assuntos
Humanos , Masculino , Feminino , Pontos de Referência Anatômicos , Tomografia Computadorizada de Feixe Cônico , Mandíbula
14.
J. appl. oral sci ; J. appl. oral sci;21(5): 437-442, Sep-Oct/2013. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-690087

RESUMO

OBJECTIVE: The purpose of this present study was to compare, by means of 3D digital casts, the anterior transverse dimension of the dental arch of newborns with and without cleft lip and palate. MATERIAL AND METHODS: The sample was composed of ninety-four children aged from 3 to 9 months divided into three study groups: Group I - children without craniofacial deformities (control group); Group II - children with unilateral cleft lip and palate; Group III - children with bilateral cleft lip and palate. Impressions were executed before lip and palate repair in patients with clefts. Dental casts were digitized using a 3D scanner linked to a computer. Measurements of the intercanine distance were measured on the digital casts. Intergroup comparisons were performed using ANOVA (p<0.05). RESULTS: The results showed a mean of 36.5 mm for unilateral cleft lip and palate group, 34.8 mm for bilateral cleft lip and palate group and 27.52 mm for the control group. There was a statistically significant difference between the control group and both groups of patients with cleft lip and palate. There was no statistically significant difference between complete unilateral and bilateral cleft lip and palate groups. CONCLUSIONS: Patients with complete cleft lip and palate were born with an increased anterior dimension of the maxillary dental arch compared to non cleft patients. .


Assuntos
Humanos , Masculino , Feminino , Lactente , Fenda Labial/patologia , Fissura Palatina/patologia , Arco Dental/anatomia & histologia , Modelos Dentários , Análise de Variância , Pontos de Referência Anatômicos , Estudos de Casos e Controles , Arco Dental/patologia , Técnica de Moldagem Odontológica , Imageamento Tridimensional , Ilustração Médica , Valores de Referência
15.
Rev. gastroenterol. Perú ; 33(1): 52-58, ene.-mar. 2013. ilus, tab
Artigo em Inglês | LILACS, LIPECS | ID: lil-692421

RESUMO

A pesar del uso globalizado y masivo de la Esofagogastroduodenoscopia estándar (EGD), el cáncer gástrico (CG) sigue siendo uno de los cánceres más comunes y continúa posicionado como el tumor maligno más frecuente en el Este de Asia, Este de Europa y partes de América Latina. Las limitaciones actuales de usar un examen no sistemático durante la EGD pueden parcialmente ser responsables de la baja incidencia del diagnóstico de CG temprano en países con una alta prevalencia de la enfermedad. Originalmente propuesta por Emura et al., la Endoscopia Sistemática Alfanumérica Codificada (SACE) es un nuevo método que facilita el examen completo y sistemático del tracto gastrointestinal alto basado en la foto-documentación secuencial con imágenes parcialmente superpuestas y que, usando una nomenclatura alfanumérica endoluminal compuesta de ocho regiones y 28 áreas proporciona el cubrimiento del total de la superficie gastrointestinal durante una endoscopia alta. Para la localización precisa tanto de zonas normales o anormales, SACE incorpora un sistema sencillo de coordenadas basado en la identificación de ciertos ejes naturales, paredes, curvaturas y puntos de referencia anatómicos endoluminales. La efectividad de SACE fue recientemente demostrada en un estudio de tamizaje que diagnosticó CG temprano con una frecuencia de 0,30% (2/650) en voluntarios sanos con riesgo promedio. Este nuevo método de examen endoscópico si se aplica de manera uniforme en el mundo, podría considerablemente aumentar la detección temprana del cáncer gástrico y cambiar significativamente la manera en que realizamos endoscopia digestiva en en nuestra era.


Despite extensive worldwide use of standard esophagogastroduodenoscopy (EGD) examinations, gastric cancer (GC) is one of the most common forms of cancer and ranks as the most common malignant tumor in East Asia, Eastern Europe and parts of Latin America. Current limitations of using non systematic examination during standard EGD could be at least partially responsible for the low incidence of early GC diagnosis in countries with a high prevalence of the disease. Originally proposed by Emura et al., systematic alphanumeric-coded endoscopy (SACE) is a novel method that facilitates complete examination of the upper GI tract based on sequential systematic overlapping photo-documentation using an endoluminal alphanumeric-coded nomenclature comprised of eight regions and 28 areas covering the entire surface upper GI surface. For precise localization or normal or abnormal areas, SACE incorporates a simple coordinate system based on the identification of certain natural axes, walls, curvatures and anatomical endoluminal landmarks. Efectiveness of SACE was recently demonstrated in a screening study that diagnosed early GC at a frequency of 0.30% (2/650) in healthy, average-risk volunteer subjects. Such a novel approach, if uniformly implemented worldwide, could significantly change the way we practice upper endoscopy in our lifetimes.


Assuntos
Humanos , Detecção Precoce de Câncer/métodos , Gastroscopia/métodos , Gastroscopia/estatística & dados numéricos , Neoplasias Gástricas/patologia , Melhoria de Qualidade
16.
Rev. Fac. Odontol. Porto Alegre ; 53(3): 1-5, set.-out. 2012. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-786820

RESUMO

Objective: To assess, using a mathematical simulation model, the participation of each coordinate involved in the formation of cephalometric angles and to determine the extent to which errors in the identification of cephalometric landmarks can, individually and collectively, influence the measurement of these angles. Material and Methods: The reference values and standard errors of 13 landmarks obtained from the analysis of 30 cephalograms were used. For each landmark, 1000 observations were simulated using the Monte Carlo method. On the basis of linear regression models, equations designed to estimate measurement errors due to landmark identification errors were obtained and analysed. Results: The coordinates most involved in the formation of the angles SNA, SNB, ANB, FMA, PPL, DFC, and AEF were Ny, Ny, Ax, Goy, Poy, Poy, and Ptmx, respectively, and the standard measurement errors for these angles were 1.2, 0.9, 0.8, 1.6, 1.5, 1.5, and 1.4, respectively. Conclusion: The standard measurement error of the angle depends on the geometric impact coefficient and the standard error of the coordinates involved in the formation of the angles, and the geometric impact coefficient varies according to the angle analysed.


Objetivos: Avaliar, empregando um modelo matemático de simulação, a participação de cada coordenada envolvida na formação de ângulos cefalométricos, assim como determinar a extensão da influência dos erros na identificação dos pontos cefalométricos, individual e coletivamente, na mensuração destes ângulos. Materiais e métodos: Foram utilizados os valores de referência e os erros padrão de 13 pontos anatômicos obtidos a partir da análise de 30 cefalogramas. Para cada ponto anatômico, foram simuladas 1000 observações utilizando o método de Monte Carlo. Com base em modelos de regressão linear, foram obtidas e analisadas equações destinadas a estimar os erros de medição devido a erros na identificação dos pontos cefalométricos. Resultados: As coordenadas mais envolvidas na formação dos ângulos SNA, SNB, ANB, FMA, PPL, DFC, e AEF foram Ny, Ny, Ax, Goy, Poy, Poy, e Ptmx, respectivamente, e os erros padrão de mensuração destes ângulos foram 1,2; 0,9; 0,8; 1,6; 1,5; 1,5 e 1,4, respectivamente. Conclusões: O erro padrão de mensuração de cada ângulo cefalométrico depende do coeficiente de impacto geométrico e do erro padrão das coordenadas dos pontos anatômicos envolvidos na formação dos mesmos, sendo que o coeficiente de impacto geométrico varia de acordo com o ângulo analisado.


Assuntos
Humanos , Pontos de Referência Anatômicos , Cefalometria/estatística & dados numéricos , Arcada Osseodentária
17.
Rev. Fac. Odontol. Porto Alegre ; 52(1/3): 39-43, jan.-dez. 2011. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-719552

RESUMO

Objetivo: A análise cefalométrica é utilizada por dentistas no auxílio ao diagnóstico, planejamento e acompanhamento dos tratamentosortodôntico, ortopédico e cirúrgico. Entretanto, a cefalometria não éuma ferramenta precisa e há erros significativos nas medidas obtidaspor examinadores diferentes ou pelo mesmo avaliador em momentosdistintos. O objetivo deste estudo foi avaliar a reprodutibilidade das medidas cefalométricas de três especialistas em radiologia odontológica e compará-las com os resultados obtidos por trêsclínicas de radiologia. Materiais e métodos: Os examinadores traçaram os cefalogramas de 39 telerradiografias convencionais da amostra utilizada por Silveira e Silveira (2006). Resultados:O teste de ANOVA revelou uma boa reprodutibilidade para 17 dos 32 fatores nas análises realizadas pelos dentistasespecialistas. Houve concordância entre os especialistas para 53,1% dos fatores, enquanto que para as clínicas de radiologia a concordância foi de somente 12,5%. Conclusão: Os resultados mostraram que os três especialistas em radiologia obtiveram maior concordância nas aanálises cefalométricas realizadas do que aquelas recebidas pelas clínicas de radiologia estudadas previamente.


Objectives: Cephalometric analysis is used by dentists to assist in thediagnosis, planning and follow-up of orthodontic, orthopedic and surgical treatments. However, cephalometry is not a precise tool, and there are significant errors in the measures obtained by the same or different examiners. The purpose of this study was to evaluate the reproducibility of cephalometric measures obtained by three specialists in oral radiology, and to compare them with the results obtained by three radiology clinics. Materials and Methods : Examiners traced cephalograms from 39 conventional cephalograms from the sample used by Silveira and Silveira (2006). ANOVA revealed good reproducibility of 17 of the 32 factors in the analyses conducted by dental specialists. Results: Agreement between dental specialists was found for 53.1% of the factors, whereas agreement for the results obtained by radiology clinics was only 12.5%. Conclusion: Results showed that tracings by the 3 radiology specialists had greater agreement than those by the radiology clinics under study.


Assuntos
Humanos , Análise de Variância , Cefalometria , Diagnóstico por Imagem , Revisão por Pares , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA