Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J. oral res. (Impresa) ; 13(1): 160-169, mayo 29, 2024. ilus
Artigo em Inglês | LILACS | ID: biblio-1563437

RESUMO

Objective: To evaluate the influence of opacity and the layering technique on the fluorescence of different composite resins. Materials and Methods: Two opacities (enamel and dentin) and the layering technique (enamel + dentin) of the composite resins: Filtek® Z350 and Palfique LX5 were evaluated in vitro. Composite resin discs were fabricated using a preformed matrix of 10 mm diameter and 0.5 mm thick for the single opacity groups and 10 mm thick for the layering technique groups, using 2 layers of 0.5 mm thickness of each opacity (n = 5). Specimens were analyzed using the Raman spectroscopy method. Data were analyzed using the Kruskall-wallis and Mann-Whitney U tests. Results: When evaluating the intensity of fluorescence, no statistically significant difference was found when comparing the layering technique and enamel opacity (p2> 0.05) and an increase in the dentin opacity value for both brands of composite resin. Regarding wavelength, no statistically significant difference was found when comparing the layering technique with enamel opacity and dentin opacity for both Filtek® Z350 and Palfique LX5® composite resins (p2 > 0.05). Conclusions: The fluorescence intensity of the layering technique is similar to enamel opacity for both composite resins. Likewise, the wavelength of the layering technique is similar to the enamel opacity and dentin opacity for both brands.


Objetive: Evaluar la influencia de la opacidad y de la técnica de estratificación en la fluorescencia de diferentes resinas compuestas. Materiales y Métodos: Se evaluó in vitro 2 opacidades (Esmalte y Dentina) y la técnica de estratificación (Esmalte + Dentina) de las resinas compuestas: Filtek® Z350 y Palfique LX5. Se fabricaron discos de resina compuesta, utilizando una matriz preformada de 10 mm de diámetro y 0,5 mm de grosor para los grupos de opacidad única y 10 mm de grosor para los grupos de técnica estratificada, utilizando 2 capas de 0,5 mm de cada opacidad (n = 5). Los especímenes se analizaron mediante el método de Espectroscopía Raman. Los datos se analizaron utilizando la prueba de Kruskall-wallis y Prueba U de Mann Whitney. Resultado: Al evaluar la intensidad de fluorescencia no se encontró diferencia estadísticamente significativa entre los pares: Técnica estratificada versus Opacidad Esmalte para ambas marcas de resina compuesta Filtek® Z350 y para Palfique LX5® (p2 > 0,05). Para longitud de onda no se encontró diferencia estadísticamente significativa entre los pares: Técnica estratificada versus Opacidad Esmalte y Técnica estratificada VS Opacidad Dentina para ambas resinas compuesta Filtek® Z350 y Palfique LX5® (p2> 0,05). Conclusión: La intensidad de fluorescencia de la técnica estratificada es similar a la opacidad Esmalte para ambas resinas compuestas. De igual manera la longitud de onda de la técnica estratificada es similar a la opacidad Esmalte y opacidad Dentina para ambas marcas.


Assuntos
Humanos , Resinas Compostas/química , Nanotecnologia/métodos , Análise Espectral , Técnicas In Vitro
2.
Acta otorrinolaringol. cir. cuello (En línea) ; 51(4): 276-284, 2024/02/07. ilus, tab
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1531201

RESUMO

Introducción: las medidas auditivo-perceptuales subjetivas GRABS (Grade [grado de gravedad], Roughness [aspereza], Asthenia [astenia], Breathiness [soplosidad] y Strain [tensión] y CAPE-V (Consensus Auditory-Perceptual Evaluation of Voice) han sido el estándar de oro en evaluar la voz. La prominencia del pico cepstral suavizado (CPPS) se impone como la medida acústica objetiva más robusta para evaluar la gravedad de la disfonía. Se evaluó el análisis cepstral del programa PRAAT en pacientes con voz patológica y no patológica en hablantes de español colombiano y los valores estándar para el CPPS en lenguaje conectado (CPPSc), comparado con el análisis perceptual de la voz (GRBAS). Métodos: estudio observacional y analítico de prueba diagnóstica, de corte transversal y multicéntrico, con 120 individuos. Se grabó la voz y se analizó el CPPSc con el programa PRAAT. Se aplicó la valoración auditiva-perceptual por dos evaluadores expertos para la escala GRBAS. Resultados: el promedio de edad fue 43,3 años, 64,2 % mujeres. La media del CPPSc en el grupo disfónico fue de 6,40 dB y en el grupo de normofónicos fue 8,54 dB con p=0,000. Sensibilidad de 83,6% y especificidad de 96,2 % para la voz patológica en los pacientes con valores de CPPSc menores a 7,38 dB. Hubo alta correlación del valor de CPPSc con la gravedad de la disfonía. Conclusiones: el valor del CPPSc mediante el programa PRAAT es una medida eficiente por su alta validez, bajo costo y fácil aplicación para evaluar objetivamente la disfonía y su gravedad.


Introduction: Subjective auditory-perceptual measurements, GRABS (Grade, Roughness, Asthenia, Breathiness y Strain) and CAPE-V (Consensus Auditory Perceptual Evaluation of Voice) have been the gold standard in voice evaluation. Recently, the smoothed cepstral peak prominence (CPPS) has been imposed as the acoustic measurement, objective and more robust for dysphonia severity. Objectives: The cepstral analysis of the PRAAT program was evaluated in patients with a patho-logical and non-pathological voice in Colombian Spanish speakers and the standard values for the CPPS in connected language (CPPSc), compared with the perceptual analysis of the voice (GRBAS). Methods: An observational, analytical, cross-sec-tional, multicenter diagnostic test was performed with 120 individuals. The voice was recorded and the CPPSc was analyzed with the PRAAT program. The auditory-perceptual assessment was applied by two expert evaluators for the GRBAS scale. Results: The average age was 43.3 ± 18.1 years, 64.2% were women. The mean CPPSc in the dysphonic group was 6.40 dB, while in the group of normophonic indi-viduals it was 8.54 dB, with significant differences between both groups (p=0.000). Sensitivity of 83.6% and specificity of 96.2%; for pathological voice was established in patients with CPPSc values less than 7.38 dB. A high correlation was found in the CPPSc value with the severity of dysphonia. Conclusions: The value of CPPSc through the Praat program is an efficient measure, due to its high validity, low cost and easy application to objectively evaluate dysphonia and its severity.


Assuntos
Humanos , Masculino , Feminino
3.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1551100

RESUMO

La espectroscopía de reflectancia en el infrarrojo cercano (NIRS) es una tecnología rápida, multiparamétrica, amigable con el ambiente, de bajo costo y gran exactitud, para el análisis de diversos componentes en alimentos, en suelo y en agricultura. El objetivo del presente estudio fue construir modelos de calibración NIRS, para la predicción de nutrientes en tejido vegetal de caña de azúcar, para producción de panela, cultivada en la región de la Hoya del río Suárez. Un total de 416 muestras de tejido fueron escaneadas en el segmento espectral Vis-NIR. El análisis quimiométrico, se realizó con el software WinISI V4.10, aplicando la regresión de mínimos cuadrados parciales modificados, junto a una validación cruzada. Se evaluaron cuatro modelos con diferentes tratamientos matemáticos y el rendimiento de las calibraciones, se hizo por medio de la validación externa, analizando las medidas de bondad de ajuste, como el coeficiente de determinación de la predicción, el error estándar de la predicción ajustado por el sesgo y la desviación predictiva residual. Los resultados muestran que el modelo de calibración para N presentó el mayor poder predictivo. Para macronutrientes, las calibraciones, con mayor poder predictivo, fueron P y K y para micronutrientes, el modelo para B, mientras que para Cu presentó el más bajo poder predictivo. Se encontraron modelos adecuados para la predicción de los contenidos de N, Ca y P; para los demás nutrientes, se recomienda ampliar el conjunto de calibración.


Near Infrared Reflectance Spectroscopy (NIRS) is a fast, multiparametric, environmentally friendly, low-cost, and highly accurate technology for the analysis of components in food, soil, and agriculture. The purpose of this study was to generate NIRS calibration models for the prediction of nutrients in plant tissue of sugarcane to panela production cultivated in the Hoya del Río Suárez region. A total of 416 tissue samples were scanned in Vis-NIR spectral segment. Chemometric analysis was performed with the WinISI V4.10 software applying modified partial least squares regression with cross-validation. Four models with different mathematical treatments were evaluated, and the performance of calibrations was made through external validation analyzing the goodness-of-fit measures as prediction determination coefficient, standard error of the bias-adjusted prediction, and residual predictive deviation. The results showed that the calibration model for N had the highest predictive power. For macronutrients, the calibrations with the best predictive power were for P and K, and micronutrients for B, while Cu presented the lowest predictive power. Adequate models were found for the prediction of N, Ca, and P. In the case of the other nutrients, it is recommended to expand the calibration set.

4.
Biomédica (Bogotá) ; Biomédica (Bogotá);41(4): 803-809, oct.-dic. 2021. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1355751

RESUMO

Resumen | El monitoreo electroencefalográfico no invasivo continuo es una técnica indispensable en los pacientes neurológicos críticos, ya que muestra de forma directa e indirecta su actividad cerebral y permite relacionar los hallazgos con su estado clínico. Es muy sensible, aunque su especificidad es menor, por lo que puede demostrar la alteración del estado de conciencia sin aclarar su etiología. El uso del registro electroencefalográfico continuo en pacientes con alteraciones del estado de conciencia, convulsiones, o estado epiléptico convulsivo y no convulsivo, se ha incrementado en los últimos años porque permite obtener información en tiempo real de la función cerebral y de los cambios en el tiempo; además, facilita la detección de crisis epilépticas subclínicas y electrográficas, estas últimas de gran importancia, ya que no presentan correlación clínica. Los hallazgos del monitoreo permiten modificar el tratamiento farmacológico y anticonvulsivo, y constituyen una gran ventaja para el médico tratante en la toma de decisiones oportunas que redunden en la mejoría del pronóstico del paciente.


Abstract | Continuous non-invasive electroencephalographic monitoring is an essential technique for critical care patients as it shows directly and indirectly the patient's brain activity and makes it possible to relate it with findings in the clinical status. It is highly sensitive, although its specificity is lower, so they can show alterations of the state of consciousness without clarifying the etiology. Continuous electroencephalographic recording in patients with altered levels of consciousness, seizures, and convulsive and non-convulsive status epilepticus has been increasing in recent years as real-time feedback of the cerebral function shows evolution changes and allows for the identification of electric and subclinical epileptic seizures that are highly important since they do not have clinical correlations. These findings in electroencephalographic monitoring also help to modify pharmacological and antiseizure treatments. For practitioners, they are advantageous when making timely decisions that impact the prognosis of the patient.


Assuntos
Cuidados Críticos , Eletroencefalografia , Análise Espectral , Oximetria
5.
Rev. Méd. Inst. Mex. Seguro Soc ; Rev. Méd. Inst. Mex. Seguro Soc;59(6): 517-527, dic. 2021. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1357536

RESUMO

Introducción: la diabetes mellitus es uno de los problemas más graves de salud pública que enfrenta México. El factor más preocupante es la falta de control de la misma, lo que incide de manera directa, causando daños severos a la salud y la calidad de vida del paciente y familiares, así como una carga económica al país. Por lo tanto, el desarrollo de un método no invasivo para la medición de la glucemia proporcionaría a los pacientes una forma sencilla e indolora de monitoreo y, en consecuencia, un mejor control de la diabetes. Objetivo: investigar, desarrollar y validar un sensor no invasivo por medio de la espectroscopía para la estimación del nivel de glucosa en sangre. Material y métodos: se realizó un análisis de estudio transversal analítico de correlación realizado en las instalaciones del laboratorio de la UMAE No 1, Bajío. Se incluyeron pacientes adultos voluntarios que acudieron al laboratorio de dicha unidad para la toma de niveles de glucosa sérica y de manera simultánea se realizó la medición a través de método no invasivo por espectroscopía y, posteriormente, se compararon ambos resultados para demostrar la validez del dispositivo. Resultados: mediante el análisis de la diferencia de medias de Bland-Altman, se identificó que solamente un paciente tuvo un valor extremo, y que el método para medir la glucosa de manera no invasiva sobreestima hasta un 10.2% del valor de glucosa central. Conclusión: comparando dichos resultados con las normas para glucómetros digitales se concluye que nuestro dispositivo es capaz de proporcionar niveles de glucosa certeros.


Background: Diabetes mellitus is one of the most serious public health problems in Mexico. The most worrying factor is the lack of control of it, which has a direct impact, causing severe damage to the health and quality of life of the patient and its family, as well as an economic burden to the health system. Therefore, the development of a non-invasive method for measuring blood glucose would provide to patients a simple and painless way of monitoring and consequently better control of diabetes. Objective: Research, development and validation of a non-invasive sensor by means of spectroscopy for the estimation of the blood glucose level. Material and methods: An analysis of a cross-sectional analytical correlation study was carried out in the facilities of the laboratory at the UMAE No. 1, Bajío. Voluntary adult patients who attended the laboratory of the UMAE to take serum glucose levels were included, and simultaneously the measurement was carried out through a non-invasive method by spectroscopy and, later, both results were compared to demonstrate the validity of the device. Results: By the Bland-Altman mean difference analysis, it was identified that only one patient had an extreme value, and that the method to measure glucose non-invasively overestimates up to 10.2% of the central glucose value. Conclusion: Comparing these results with the standards for digital glucometers, it is concluded that our device is capable of providing accurate glucose levels.


Assuntos
Humanos , Masculino , Feminino , Análise Espectral , Glicemia , Diabetes Mellitus , México , Qualidade de Vida , Diagnóstico Clínico , Saúde Pública , Glucose , Glicosúria
6.
Rev. colomb. anestesiol ; 49(2): e201, Apr.-June 2021. tab, graf
Artigo em Inglês | LILACS, COLNAL | ID: biblio-1251498

RESUMO

Abstract Introduction The analysis of the electrical activity of the brain using scalp electrodes with electroencephalography (EEG) could reveal the depth of anesthesia of a patient during surgery. However, conventional EEG equipment, due to its price and size, are not a practical option for the operating room and the commercial units used in surgery do not provide access to the electrical activity. The availability of low-cost portable technologies could provide for further research on the brain activity under general anesthesia and facilitate our quest for new markers of depth of anesthesia. Objective To assess the capabilities of a portable EEG technology to capture brain rhythms associated with the state of consciousness and the general anesthesia status of surgical patients anesthetized with propofol. Methods Observational, cross-sectional study that reviewed 10 EEG recordings captured using OpenBCI portable low-cost technology, in female patients undergoing general anesthesia with propofol. The signal from the frontal electrodes was analyzed with spectral analysis and the results were compared against the reports in the literature. Results The signal captured with frontal electrodes, particularly α rhythm, enabled the distinction between resting with eyes closed and with eyes opened in a conscious state, and sustained anesthesia during surgery. Conclusions It is possible to differentiate a resting state from sustained anesthesia, replicating previous findings with conventional technologies. These results pave the way to the use of portable technologies such as the OpenBCI tool, to explore the brain dynamics during anesthesia.


Resumen Introducción El análisis de la actividad eléctrica cerebral mediante electrodos ubicados sobre el cuero cabelludo con electroencefalografía (EEG) podría permitir conocer la profundidad anestésica de un paciente durante cirugía. Sin embargo, los equipos de EEG convencionales, por su precio y tamaño, no son una alternativa práctica en quirófanos y los equipos comerciales usados en cirugía no permiten acceder a la actividad eléctrica. Disponer de tecnologías portables y de bajo costo aumentaría el número de investigaciones sobre la actividad cerebral bajo anestesia general y facilitaría la búsqueda de nuevos marcadores para la profundidad anestésica. Objetivo Evaluar la capacidad de una tecnología EEG portable de adquirir ritmos cerebrales relacionados con el estado consciente y el estado de anestesia general de pacientes en cirugía anestesiados con propofol. Métodos Estudio observacional de corte transversal en el que se analizaron datos de 10 registros EEG obtenidos mediante tecnología portable y de bajo costo OpenBCI, de pacientes de sexo femenino que fueron sometidas a anestesia general con propofol. La señal obtenida de los electrodos frontales se analizó mediante análisis espectral y se contrastaron los resultados con lo descrito en la literatura. Resultados La señal obtenida con electrodos frontales, especialmente el ritmo α, permitió diferenciar el reposo con ojos cerrados y ojos abiertos en estado consciente, del estado de mantenimiento de la anestesia durante cirugía. Conclusiones Se logra la diferenciación de estado de reposo y de mantenimiento de la anestesia replicando hallazgos previos de tecnologías convencionales. Estos resultados abren la posibilidad de utilizar las tecnologías portables como el OpenBCI para investigar la dinámica cerebral durante la anestesia.


Assuntos
Humanos , Análise Espectral , Tecnologia , Eletroencefalografia , Anestesia Geral , Mapeamento Encefálico , Propofol , Estudos Observacionais como Assunto
7.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1354919

RESUMO

Objetivo: Investigar la aplicación del niosoma como nanoportador de extracto de salvia (Salvia officinalis L.) mediante espectroscopia y quimiometría. Material y método: En este estudio, se prepararon nanopartículas de niosoma que contienen colesterol y sin colesterol mediante el método de hidratación de película fina. El extracto etanólico de salvia se extrajo mediante microondas y se cargó dentro de las nanopartículas de niosoma. El tamaño de las nanopartículas se determinó mediante microscopía electrónica de barrido de imágenes de campo (FE-SEM). El potencial zeta de los niosomas se determinó mediante dispersión dinámica de luz (DLS). Para investigar el tipo de interacciones entre los tensioactivos y el colesterol utilizados en la estructura del niosoma, se utilizó la espectroscopia infrarroja por transformada de Fourier (FT-IR). Se investigó la liberación de fármaco durante 5 días consecutivos en tampón fosfato salina (PBS) 0/01 M con pH = 7,4 a T = 37ºC. Resultados: El potencial zeta de los niosomas con colesterol y sin colesterol fue de -24 / 1 y -15 / 6 mv. La capacidad de carga del fármaco en el rango de concentración (1-3% p / p de niosum) para ambos tipos de niosoma estuvo entre 61% y 93%. Conclusión: Estos resultados muestran que la tasa de liberación de niosma con colesterol es significativamente más regular y más baja que la de niosoma sin colesterol. En general, se puede concluir que el niosoma puede ser un nanoportador adecuado para el suministro de extracto hidrófilo de la salvia.


Objetive:Investigation the application of niosome as a nanocarrier for sage (Salvia officinalis L.) extract by spectroscopy and chemometrics. In this Material and Method:study,niosomenanoparticlescontainingcholesterolandwithoutcholesterolwere prepared by thin film hydration method. Ethanol extract of sage was extracted by microwave and loaded inside the niosome nanoparticles. The size of the nanoparticles was determined by field imaging scanning electron microscopy (FE-SEM). The zeta potential of the niosomes was determined by Dynamic light scattering (DLS). to investigate the type of interactions between surfactants and cholesterol used in the niosome structure, Fourier transform infrared spectroscopy (FT-IR) was used. Drug release was investigated for 5 consecutive days in phosphate buffer salin (PBS) 0/01 M with pH=7.4 at T=370C. The zeta potential of the niosomes with cholesterol and without Results:cholesterol was -24/1&-15/6 mv . The loading capacity of the drug in the concentration range (1-3% w / w of niosum) for both types of niosome was between 61% and 93%. Conclusion:This results show that the release rate of niosme with cholesterol is significantly more regular and lower than of niosome without cholesterol. In general, it can be concluded that niosome can be a suitable nano-carrier for delivery of hydrophilic extract of the sage.

8.
Rev. cuba. med. mil ; 48(3)jul.-set. 2019.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1508281

RESUMO

Introducción: La exploración del sistema vestibular exige una evaluación precisa, sistemática y completa de la respuesta vestíbulo-ocular. Actualmente los sistemas solo analizan secciones definidas subjetivamente por especialistas clínicos en los registros del nistagmo, y se calculan parámetros en el dominio del tiempo, que a menudo se ven afectados por las interferencias y el ruido en el sistema de exploración durante las pruebas vestibulares. Objetivo: Presentar un nuevo sistema para la exploración y caracterización del nistagmo obtenido mediante electronistagmografía. Métodos: Los registros fueron adquiridos a partir de pruebas rotatorias en una muestra de 49 sujetos, se introdujo el análisis espectro temporal del nistagmo inducido, que permitió definir la zona de mayor interés clínico para el análisis durante las pruebas. Resultados: Se obtuvo un nuevo indicador espectro temporal, detector de enfermedades vestibulares, basado en la comparación del comportamiento del análisis espectral del nistagmo en la sección central de fases de velocidad constante y desaceleración de los registros clínicos. Se obtuvo una buena sensibilidad (90,32 %) y una buena especificidad (88,89 %) del nuevo indicador, relacionado con la determinación de personas enfermas en uno o ambos laberintos. Conclusiones: El método y el nuevo indicador definido, presentaron mayor capacidad diagnóstica, que el habitual análisis cuantitativo de las señales; mostraron una sensibilidad y especificidad superiores. Permiten llegar a conclusiones en la práctica clínica diaria, con mucha más rapidez que la valoración de los parámetros temporales habitualmente utilizados en los análisis, que presentan como debilidad, el amplio intervalo de valores normales.


Introduction: The exploration of the vestibular system requires an accurate, systematic and complete evaluation of the vestibule-ocular response. Currently, systems only analyze sections subjectively defined by clinical specialists in nystagmus records, and time domain parameters are calculated, which are often affected by interference and noise in the scanning system during vestibular tests. Objective: To present a new system for the exploration and characterization of nystagmus obtained by electronistagmography. Methods: The records were acquired from rotary tests in a sample of 49 subjects, the temporal spectrum analysis of the induced nystagmus was introduced, which allowed defining the area of ​​greatest clinical interest for the analysis during the tests. Results: A new temporal spectrum indicator was obtained, detector of vestibular diseases, based on the comparison of the behavior of the spectral analysis of nystagmus in the central section of constant velocity phases and deceleration of clinical records. A good sensitivity (90.32%) and a good specificity (88.89%) of the new indicator were obtained, related to the determination of sick people in one or both labyrinths. Conclusions: The method and the new defined indicator, presented greater diagnostic capacity, than the usual quantitative analysis of the signals; they showed superior sensitivity and specificity. They allow conclusions to be reached in daily clinical practice, much faster than the assessment of the temporal parameters usually used in the analyzes, which present as a weakness, the wide range of normal values.

9.
Rev. bras. med. esporte ; Rev. bras. med. esporte;23(3): 208-212, May-June 2017. tab, graf
Artigo em Português | LILACS | ID: biblio-898971

RESUMO

RESUMO Introdução: A variabilidade da frequência cardíaca (VFC) tem sido considerada um mecanismo de modulação do sistema nervoso autônomo. A diminuição da VFC pode estar associada à síndrome metabólica (SM). Objetivo: Comparar a VFC e variáveis de saúde em indivíduos com e sem SM. Métodos: Cento e dezenove participantes foram divididos em dois grupos: sem SM (SSM, n = 68) e com SM (CSM, n = 51). Foi avaliada a análise espectral da VFC em repouso, durante teste cardiopulmonar de exercício (TCPE) e na recuperação em bandas de baixa frequência (LF = 0,04-0,15 Hz), alta frequência (HF = 0,15-0,4 Hz) e razão LF/HF. Adicionalmente, a frequência cardíaca (FC) de repouso (FCrep), FC máxima (FCmáx), pressão arterial sistólica (PAS) e diastólica (PAD), glicemia, perfil lipídico, consumo de oxigênio pico (VO2pico) e composição corporal foram avaliados. Resultados: A FCrep e o VO2pico não apresentaram diferenças entre o CSM e o SSM (73,3 ± 9,1 vs. 70,1 ± 11,0 bpm) (26,8 ± 4,6 vs. 28,1 ± 6,6 ml.kg-1.min-1), respectivamente. A VFC foi similar entre os grupos nos diferentes momentos analisados. A glicemia (99,8 ± 22,5 vs. 87,6 ± 8,6 mg/dl) foi superior no CSM comparado ao SSM. Os valores de triglicérides (159,5 ± 68,8 vs. 89,2 ± 34,3 mg/dl) e VLDL-c (31,9 ± 13,8 vs. 17,8 ± 6,9 mg/dl) foram superiores no CSM comparado ao SSM. O HDL-c (40,7 ± 11,5 vs. 49,3 ± 9,8 mg/dl) foi menor no CSM comparado ao SSM. O IMC (33,1 ± 4,7 vs. 30,8 ± 3,8 Kg/m²) foi superior no CSM comparado ao SSM. A PAS (128,6 ± 12,9 vs. 119,5 ± 11,3 mmHg) e a PAD (77,2 ± 10,5 vs. 72,9 ± 8,1 mmHg) foram superiores no CSM comparado ao SSM, p < 0,05. Conclusão: Os resultados sugerem que a presença de SM não é suficiente para provocar alterações nos índices de VFC em repouso, durante teste cardiopulmonar de exercício (TCPE) e na recuperação quando os pacientes são comparados a indivíduos sem a doença.


ABSTRACT Introduction: Heart rate variability (HRV) has been considered a modulation mechanism of the autonomic nervous system. The reduction of HRV may be associated with metabolic syndrome (MS). Objective: To compare the HRV and health variables in individuals with and without MS. Methods: One hundred and nineteen participants were divided into two groups: without MS (WOMS, n=68) and with MS (WMS, n=51). We evaluated the spectral analysis of HRV at rest, during cardiopulmo-nary exercise testing (CPET) and recovery in low frequency bands (LF = 0.04-0.15 Hz), high frequency (HF = 0.15-0.4 Hz) and LF/HF ratio. Resting heart rate (HRres), maximum heart rate (HRmax), systolic blood pressure (SBP) and diastolic (DBP), blood glucose, lipid profile, peak oxygen consumption (VO2peak) and body composition were also evaluated. Results: There were no differences between HRres and VO2peak between the WMS and WOMS groups (73.3±9.1 vs. 70.1±11.0 bpm), (26.8±4.6 vs. 28.1±6.6 ml.kg-1.min-1), respectively. HRV was similar between the groups at the different moments analyzed. The blood glucose levels (99.8±22.5 vs. 87.6±8.6 mg/dl) were higher in WMS compared to WOMS. Triglyceride values (159.5±68.8 vs. 89.2±34.3 mg/dl) and VLDL-c (31.9±13.8 vs. 17.8±6.9 mg/dl) were higher in WMS compared to WOMS. HDL-c (40.7±11.5 vs. 49.3±9.8 mg/dl) was lower in WMS compared to WOMS. BMI (33.1±4.7 vs. 30.8±3.8 kg/m²) was higher in WMS compared to WOMS. The SBP (128.6±12.9 vs. 119.5±11.3 mmHg) and DBP (77.2±10.5 vs. 72.9± 8.1mmHg) were higher in WMS com-pared to WOMS, p<0.05. Conclusion: The results suggest that the presence of MS is not sufficient to induce changes in HRV at rest, during cardiopulmonary exercise test (CPET), and in recovery when patients are compared to healthy individuals.


RESUMEN Introducción: La variabilidad de la frecuencia cardiaca (VFC) ha sido considerada como un mecanismo de modulación del sistema nervioso autónomo. La disminución de VFC puede estar asociada con el síndrome metabólico (SM). Objetivo: Comparar la VFC y variables de salud en individuos con y sin SM. Métodos: Ciento diecinueve sujetos se dividieron en dos grupos: sin SM (SSM, n = 68) y con SM (CSM, n = 51). Se evaluó el análisis espectral de la VFC en reposo durante las pruebas de ejercicio cardiopulmonar (PECP) y la recuperación en banda de baja frecuencia (LF = 0,04-0,15 Hz), alta frecuencia (HF = 0,15-0,4 Hz) y la relación LF/HF. Además, se evaluaron la frecuencia cardiaca en reposo (FCrep), FC máxima (FCmáx), presión arterial sistólica (PAS) y diastólica (PAD), glicemia, perfil lipídico, consumo pico de oxígeno (VO2pico) y composición corporal. Resultados: FCrep y VO2pico no mostraron diferencias entre CSM y SSM (73,3 ± 9,1 vs. 70,1 ± 11,0 bpm) (26,8 ± 4,6 vs. 28,1 ± 6,6 ml.kg-1.min-1), respectivamente. La VFC fue similar entre los grupos en diferentes momentos analizados. La glicemia (99,8 ± 22,5 vs. 87,6 ± 8,6 mg/dl) fue mayor en CSM en comparación con SSM. Los valores de triglicéridos (159,5 ± 68,8 vs. 89,2 ± 34,3 mg/dl) y VLDL-C (31,9 ± 13,8 vs. 17,8 ± 6,9 mg/dl) fueron más altos en CSM en comparación con SSM. HDL-C (40,7 ± 11,5 vs. 49,3 ± 9,8 mg/dl) fue menor en CSM en comparación con el SSM. El IMC (33,1 ± 4,7 vs. 30,8 ± 3,8 kg/m²) fue mayor en CSM en comparación con SSM. La PAS (128,6 ± 12,9 vs. 119,5 ± 11,3 mmHg) y la PAD (77,2 ± 10,5 vs. 72,9 ± 8,1 mmHg) fueron más altas en CSM en comparación con SSM, p < 0,05. Conclusión: Los resultados sugieren que la presencia de SM no es suficiente para provocar cambios en los índices de VFC en reposo durante las pruebas de ejercicio cardiopulmonar (PECP) y en la recuperación cuando se comparan los pacientes y los individuos saludables.

10.
Medisan ; 21(3)mar. 2017.
Artigo em Espanhol | CUMED | ID: cum-70015

RESUMO

La introducción y aplicación de métodos matemáticos y cibernéticos para el estudio de la variabilidad del ritmo cardiaco, así como su regulación se inició en la Unión Soviética; su desarrollo estuvo vinculado principalmente a los estudios y análisis evaluativos realizados a los cosmonautas en la década del 60 del siglo pasado. Se expone la experiencia sobre el tema realizada por primera vez en el país, a inicios de la década siguiente, en la Facultad de Ciencias Médicas de Santiago de Cuba. De igual manera, se señalan las distintas etapas y facetas que tuvieron tales estudios y su significación. A través de este trabajo se puede constatar que aquellos enfoques y resultados abrieron las posibilidades para continuar dichos estudios en otros campos, estados y condiciones en los años posteriores hasta el presente(AU)


The introduction and implementation of mathematical and cybernetic methods for the study of the heart rhythm variability, as well as their regulation began in the Soviet Union; their development was linked mainly to the evaluative studies and analysis carried out to the cosmonauts last century during the 60s. The experience on the topic carried out for the first time in the country is exposed, at the beginnings of the following decade, in the Medical Sciences Faculty in Santiago de Cuba. In a same way, the different stages and sides that had such studies and their significance are pointed out. Through this work you can verify that those approaches and results opened the possibilities to continue these studies in other fields, states and conditions in the following years until the present time(AU)


Assuntos
Humanos , Frequência Cardíaca , Cibernética , História da Medicina , Análise Espectral
11.
Medisan ; 21(3)mar. 2017.
Artigo em Espanhol | LILACS | ID: biblio-1006067

RESUMO

La introducción y aplicación de métodos matemáticos y cibernéticos para el estudio de la variabilidad del ritmo cardiaco, así como su regulación se inició en la Unión Soviética; su desarrollo estuvo vinculado principalmente a los estudios y análisis evaluativos realizados a los cosmonautas en la década del 60 del siglo pasado. Se expone la experiencia sobre el tema realizada por primera vez en el país, a inicios de la década siguiente, en la Facultad de Ciencias Médicas de Santiago de Cuba. De igual manera, se señalan las distintas etapas y facetas que tuvieron tales estudios y su significación. A través de este trabajo se puede constatar que aquellos enfoques y resultados abrieron las posibilidades para continuar dichos estudios en otros campos, estados y condiciones en los años posteriores hasta el presente


The introduction and implementation of mathematical and cybernetic methods for the study of the heart rhythm variability, as well as their regulation began in the Soviet Union; their development was linked mainly to the evaluative studies and analysis carried out to the cosmonauts last century during the 60s. The experience on the topic carried out for the first time in the country is exposed, at the beginnings of the following decade, in the Medical Sciences Faculty in Santiago de Cuba. In a same way, the different stages and sides that had such studies and their significance are pointed out. Through this work you can verify that those approaches and results opened the possibilities to continue these studies in other fields, states and conditions in the following years until the present time.


Assuntos
Humanos , Análise Espectral , Cibernética , Frequência Cardíaca , Correlação de Dados , História da Medicina
12.
Rev. cuba. hig. epidemiol ; 52(3): 301-313, set.-dic. 2014. ilus
Artigo em Espanhol | LILACS | ID: lil-752964

RESUMO

Introducción: algunas variables meteorológicas pudieran influir en el estado de salud de las personas y se admite un cambio climático antrópico y global en marcha. Objetivo: identificar el comportamiento de las temperaturas secas extremas del aire y su posible relación con las infecciones respiratorias agudas. Métodos: se efectúa un análisis de series cronológicas en Ancash, Perú. El análisis se dirige a las temperaturas secas extremas del aire y la incidencia de las infecciones respiratorias agudas, en un período reciente sobre una base mensual. Se utilizó el método no paramétrico de espectro de potencia bivariado, se consideraron densidades espectrales, coherencias y fases para identificar regularidades en las estructuras de frecuencias de las series temporales. La variable dependiente en la fortaleza de enlace y relación de fase fue la incidencia de las infecciones respiratorias agudas. También su empleó el método paramétrico univariado ARIMA (p,d,q) para modelación univariada. Resultados: se identificaron periodicidades anuales de la temperatura diaria mínima mensual promedio en contrafase con análoga periodicidad de la incidencia local de las infecciones respiratorias agudas; y de la temperatura diaria máxima mensual promedio cuasi en fase con las infecciones respiratorias agudas. Conclusiones: el calentamiento no fue confirmado. Las infecciones respiratorias agudas mostraron tendencia oscilante en el periodo analizado(AU)


Introduction: some meteorological variables could influence the health of individuals and anthropogenic global climate change and launch is supported. Objectives: this study attempts to identify regularities of behavior of extreme dry air temperatures and their possible relation to acute respiratory infections (SARI). Method: a time series analysis in Ancash, Peru is made. The analysis addresses the extreme dry air temperatures and the incidence of HCAI, in a recent period on a monthly basis. Nonparametric method of bivariate power spectrum, considering spectral densities, coherences and phases to identify regularities in the structure of the time series frequencies, bond strength and phase relationship, where the dependent variable was the incidence of HCAI was used ; Also the parametric method univariate ARIMA (p, d, q) for univariate modeling. Result: annual periodicity of the average monthly daily minimum temperature in antiphase with periodicity comparable to the local incidence of HCAI and the monthly average daily maximum temperature in quasi-phase with the IRAS identified. To this persistence process first order is added. Conclusions: the heating was not confirmed. The IRAS showed oscillating trend in the period analyzed(AU)


Assuntos
Humanos , Infecções Respiratórias/epidemiologia , Mudança Climática , Estatísticas não Paramétricas , Peru
13.
Rev. bras. med. esporte ; Rev. bras. med. esporte;19(6): 457-461, nov.-dez. 2013. graf
Artigo em Português | LILACS | ID: lil-697998

RESUMO

INTRODUÇÃO: A reprodutibilidade da atividade eletromiográfica de superfície (EMG) é mais estudada em protocolos que envolvem contrações isométricas. Alguns fatores relacionados às contrações dinâmicas podem contribuir para a instabilidade do sinal mioelétrico e dificultar a reprodutibilidade da medida da EMG. OBJETIVO: Determinar a reprodutibilidade teste-reteste e quantificar o erro técnico da medida da frequência mediana (FM) e da amplitude (root mean square, RMS) da EMG, em contrações dinâmicas e estáticas. MÉTODOS: Dez sujeitos foram testados em dois dias, sendo a atividade EMG registrada na maior porção do bíceps braquial. No primeiro dia foi feito o teste de uma repetição máxima (1RM) e de contração voluntária máxima (CVM). No segundo dia foram realizadas duas séries de 10 contrações dos flexores do cotovelo com 75% de 1RM, entremeadas por 1 h em repouso. Antes de cada série foi realizada uma CVM. RESULTADOS: Para a FM e RMS foi observado alto coeficiente de correlação intraclasse para o sinal do bíceps braquial (CCI = 0,90-0,98 para a FM; CCI = 0,89-0,94 para o RMS) e de baixo para moderado coeficiente de variação (CV = 2,5-6,2% para a FM; CV = 14,6-16,3% para o RMS) em ambos os testes. Não foi observada diferença significativa entre teste e reteste (p > 0,05). CONCLUSÃO: A FM e o RMS apresentam alta confiabilidade e baixo a moderado erro em contrações estáticas e dinâmicas, possibilitando o uso da EMG para investigação da fadiga e de desordens neuromusculares.


INTRODUCTION: Reproducibility of electromyographic activity (EMG) is the most studied in protocols involving isometric contractions. Some factors related to dynamic contractions may contribute to the instability of the myoelectric signal and affect the reproducibility of the measurement of EMG. OBJECTIVE: To determine the test-retest reproducibility and quantify the technical error of the measurement of the median frequency (MF) and amplitude (root mean square, RMS) of the surface EMG in static and dynamic contractions. METHODS: Ten subjects were tested in two days with the EMG activity recorded for the greatest portion of the biceps brachii tendon. In the first day the subjects did one test of maximum repetition (1MR) and maximal voluntary contraction (MVC). On the second day the subjects performed two sets of 10 dynamic contractions of the elbow flexors at 75% of 1MR interspersed by 1 h at rest. Before each set one MVC was performed. RESULTS: For both MF and RMS, was observed high intraclass reliability for biceps brachii (ICC = 0.90-0.98 for MF; ICC = 0.89-0.94 for RMS) and low to moderate coefficient of variation (CV = 2.5-6.2% for MF; CV =14.6-16.3% for RMS) in both tests. No significant difference between test and retest was found (p>0.05). CONCLUSION: The MF and RMS have high reliability and low to moderate error in static and dynamic contractions, enabling the use of EMG for the investigation of fatigue and neuromuscular disorders.


INTRODUCCIÓN: La reproducibilidad de la actividad electromiográfica de superficie (EMG) es más estudiada en protocolos que involucran contracciones isométricas. Algunos factores relacionados con las contracciones dinámicas pueden contribuir para la inestabilidad de la señal mioeléctrica y dificultar la reproducibilidad de la medida de la EMG. OBJETIVO: Determinar la reproducibilidad prueba-nueva prueba y cuantificar el error técnico cuanto a la medida de la frecuencia mediana (FM) y de la amplitud (root mean square, RMS) de la EMG de superficie, en contracciones dinámicas y estáticas. MÉTODOS: diez individuos fueron examinados en dos días, siendo la actividad EMG registrada en el área más grande del bíceps braquial. En el primer día, se hizo la prueba de una repetición máxima (1RM) y de contracción voluntaria máxima (CVM). En el segundo día, se realizaron dos series de 10 contracciones de los flexores del codo, con 75% de 1RM, alternadas por 1 hora en reposo. Antes de cada serie, se hizo una CVM. RESULTADOS: Para la FM y el RMS se observó un alto coeficiente de correlación para la señal del bíceps braquial (CCI = 0,90-0,98 para la FM; CCI = 0,89-0,94 para el RMS) y un coeficiente de variación de bajo para moderado (CV = 2,5-6,2% para la FM; CV = 14,6-16,3% para el RMS) en ambas pruebas. No se observó una diferencia significativa entre prueba y nueva prueba (p > 0,05). CONCLUSIÓN: La FM y el RMS presentan alta confiabilidad, y error de bajo a moderado en contracciones estáticas y dinámicas, posibilitando el uso de la EMG para investigación de la fatiga y de desórdenes neuromusculares.

14.
Gac. méd. Caracas ; 116(1): 3-9, mar. 2008. ilus
Artigo em Espanhol | LILACS | ID: lil-630517

RESUMO

La tecnología ultrasónica Doppler ha resultado ser una herramienta fundamental para la evaluación de la fisiología fetal, dando información importante sobre el estado hemodinámico fetal. Teniendo en cuenta que no sólo el desarrollo y crecimiento normal del feto y su bienestar intraúterino depende de una adecuada función de la circulación útero placentaria y feto placentaria, sino de otras estructuras orgánicas, es por lo que este método abre una línea de investigación dentro del campo de la fisiología fetal. El propósito de esta revisión es exponer de forma clara los conceptos relacionados con el desarrollo y fisiología de la respiración fetal abordando técnicas no invasivas de evaluación del bienestar fetal como la tecnología Doppler color y con la cual es posible estudiar el movimiento del líquido amniotico a través del flujo trasnasal. Es pues factible analizar, cualitativa y cuantitativamente, las ondas de velocidad de dicho flujo a través del análisis espectral de los movimientos respiratorios fetales, relacionados intimamente con la máxima producción de esteroides fetales responsables de la madurez pulmonar fetal. Se presentan las diferentes metodologías y recursos diagnósticos aplicados en los últimos años en la evaluación de los movimientos respiratorios en el bienestar fetal y su importancia. Se realiza una breve descripción de la fisiología y desarrollo del sistema respiratorio fetal


Doppler ultrasound technology has been the main tool for monitoring fetal physiology, giving important information about fetal haemodinamic status. We are aware that normal fetal growing and development and its intra womb wellbeing depends on an accurate uterus-placental blood circulation as fetal-placental, but with other organic structures, and this is the reason why this method opens a wide investigation line in the field of fetal physiology. Our purpose is to expose clearly the concepts involved in fetal breath development and physiology with non invasive techniques of fetal wellbeing such as color Doppler technology, by witch is possible to study the movement of amniotic flux through transnasal flux, as we can evaluate quantitatively by the velo-city waves of such flux through the spectral analysis of fetal breath movement, closely related to the higher production of fetal steroids responsible of fetal lung maturation. Different methodologies are presented and diagnostic resources applied in this last years over the bresth movements and its relation to fetal wellbeing and its importance. We also do a description of fetal breath system development and physiology


Assuntos
Humanos , Feminino , Gravidez , Asfixia Neonatal/fisiopatologia , Asfixia Neonatal , Doenças Fetais/prevenção & controle , Lesões Pré-Natais/prevenção & controle , Líquido Amniótico , Movimento Fetal/fisiologia , Ultrassonografia Pré-Natal/métodos , Cuidado Pré-Natal/métodos , Fenômenos Fisiológicos/fisiologia
15.
Rev Neurol ; 44(3)Feb. 2007. ilus, tab, graf
Artigo em Espanhol | CUMED | ID: cum-39836

RESUMO

Objetivo. Evaluar la contribución de la monitorización prolongada videoelectroencefalográfica (video EEG) complementada con análisis espectral y de las fuentes generadoras del electroencefalograma (EEG) en la identificación de la zona epileptogénica de pacientes con epilepsia del lóbulo temporal medial candidatos a cirugía resectiva no lesional. Pacientesy métodos. Se evaluaron los patrones electrográficos del inicio ictal en más de 667 crisis correspondientes a 41 pacientes con diagnóstico clínico de epilepsia parcial resistente a fármacos. Para el análisis se utilizaron el software Harmonie y la tomografía eléctrica de resolución variable (VARETA). Resultados. Mediante video-EEG se determinó que el 53,6por ciento de lospacientes evaluados presentaba crisis parciales complejas de origen temporal; éstas se caracterizaron por una frecuencia media de 5,56 ± 1,56 Hz, mientras que las no temporales presentaron una frecuencia en el rango de 9,17 ± 3,32 Hz. La localizacióntopográfica de la frecuencia ictal dominante durante el período de energía espectral máxima en los pacientes conepilepsia del lóbulo temporal permitió distinguir a un grupo de pacientes con crisis mesiales y otros no mesiales que superaron el número determinado por la inspección visual del EEG: un 78,9 frente a un 47,3por ciento, respectivamente. Se evidenció unacoincidencia del 100por ciento entre la zona de inicio ictal definida por EEG de superficie complementada con análisis espectral, el generador de esta actividad definido por VARETA y la zona epileptogénica. Conclusiones. La información localizadora aportadapor el video-EEG complementada con el análisis espectral y de las fuentes del EEG permite localizar de forma no invasiva la zona epileptogénica en pacientes con epilepsia del lóbulo temporal medial aun cuando los estudios imaginológicos estructurales evidencian ausencia o bilateralidad de anomalías(AU)


Summary. Aim. To evaluate the value of prolonged video electroencephalographic (video-EEG) monitoring complemented with spectral and EEG source analysis in identifying the epileptogenic area in patients with medial temporal lobe epilepsy who are candidates for non-lesional resective surgery. Patients and methods. The electrographic patterns during the onset of seizures were evaluated in over 667 seizures from 41 patients with a clinical diagnosis of medication-resistant partial epilepsy. Analyses were performed using Harmonie software and variable resolution electrical tomography (VARETA). Results. Video- EEG was used to determine that 53.6percent of the patients evaluated suffered complex partial seizures of a temporal origin; these were characterised by having an average frequency of 5.56 ± 1.56 Hz, while the non-temporal seizures displayed a frequency within the range 9.17 ± 3.32 Hz. The topographic location of the dominant ictal frequency during the period of maximum spectral energy in patients with temporal lobe epilepsy enabled us to draw a distinction between a group of patients withmesial seizures and those with non-mesial seizures that exceeded the number that was determined by visual inspection of the EEG, that is, 78.9 versus 47.3percent, respectively. There was a 100percent coincidence between the area where the seizures began asdefined by surface EEG complemented with spectral analysis, the generator of this activity as defined by VARETA and the epileptogenic region. Conclusions. The localising information provided by video-EEG complemented with spectral and EEG source analysis allows for non-invasive location of the epileptogenic region in patients with medial temporal lobe epilepsy even when structural imaging studies show an absence or bilaterality of abnormalities(AU)


Assuntos
Humanos , Eletroencefalografia/métodos , Epilepsia do Lobo Temporal/diagnóstico , Epilepsia do Lobo Temporal/fisiopatologia , Epilepsia do Lobo Temporal/terapia , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA