Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Talanta ; 281: 126818, 2025 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-39277935

RESUMO

This study introduces an innovative approach for quantifying isomeric pollutants utilizing an amperometric sensor. The determination of the isomers hydroquinone and catechol is based on the use of a glassy carbon electrode modified with Cu@PtPd/C nanoparticles (Cu@PtPd/C/GCE) in core-shell form, showing significant electrocatalytic activity in the oxidation of the later compounds. The determination was carried out at two different potentials: one at which where only hydroquinone is oxidized, and another in which where both hydroquinone and catechol are oxidized. Using these potentials, two calibration curves were built, one for the quantification of hydroquinone and the other for both isomers. Subsequently, the quantification of catechol was performed using a strategy based on the calculation of a difference using the information collected in the first step. The experiments using hydrogen peroxide as a redox probe demonstrate a clear synergistic effect in the catalytic reduction of hydrogen peroxide at -0.100 V, when Pt, Pd and Cu are incorporated into the core-shell nanostructure. The best performance was achieved with Cu@PtPd/C/GCE 1.00 mg mL-1. For the selected sensor, the analytical parameters are very competitive compared to similar devices reported in recent years for hydroquinone and catechol, with comparable linearity ranges of 0.010-0.200 mmol L-1 (hydroquinone) and 0.005-0.500 mmol L-1 (catechol), low limits of detection (LODs) of 14.0 nmol L-1 (S/N = 3.3) and 1.75 nmol L-1 (S/N = 3.3) for hydroquinone and catechol. The resulting sensor platform has been successfully applied for the quantification of hydroquinone and catechol in river and tap water and could be a promising candidate for environmental monitoring and drinking water safety.

2.
Talanta ; 186: 354-361, 2018 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-29784372

RESUMO

This study reports the preparation and characterization of nickel/lead hydroxide nanoparticles used to construct electrochemical sensors, which were investigated for amperometric quantification of N-acetylcysteine (NAC). The newly synthesised material presents good uniformity, with the lead (II) ions homogenously incorporated into the alpha nickel hydroxide crystal structure, confirmed by X-ray diffraction, transmission electron microscopy and X-ray photoelectron spectroscopy analyses. Films of nanoparticles (3 nm in size) were prepared on conductive fluorine-doped tin oxide-coated glass slides and used connected to a specially built batch injection analysis (BIA) cell with a capacity of only 4 mL and the electrode positioned in the bottom. To attain optimal analytical performance, the main parameters for BIA measurements (volume injected, different velocities of injection and best distance of the pipette from the electrode) were evaluated, as was the working potential, to determine the optimal conditions. Linear responses were obtained for the concentration range from 20 to 220 µmol L-1, and the limits of detection (3σ/slope) and quantification (10σ/slope) were calculated as 0.23 µmol L-1 and 0.70 µmol L-1, respectively. The new NAC sensor does not exhibit a memory effect and has enormous potential utility in the quantitative determination of N-acetylcysteine in drugs. The results of the analysis of NAC obtained using BIA presented good concordance with those obtained by chromatography. The analytical frequency attained using BIA (120 analysis h-1) compares very favourably with the one obtained using chromatography (6 analysis h-1).


Assuntos
Acetilcisteína/análise , Técnicas Eletroquímicas , Análise de Injeção de Fluxo , Hidróxidos/química , Nanoestruturas/química , Técnicas Eletroquímicas/instrumentação , Eletrodos , Análise de Injeção de Fluxo/instrumentação
3.
J Colloid Interface Sci ; 468: 34-41, 2016 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-26821149

RESUMO

Hexagonal close packed (hcp) nickel nanoparticles stabilized by polyvinylpyrrolidone (PVP) were synthesized through the thermal treatment of face centered cubic (fcc) nickel nanoparticles. Controlling both the temperature of the heat treatment and the amount of PVP was possible the control of the hcp/fcc rate in the samples, where the higher Ni/PVP ratio produces only the hcp-nickel phase (average size of 8.9 nm) highly stable in air. The crystalline structure, the presence of PVP, the size of the nanoparticles and the stability of the hcp-nickel were confirmed using X-ray diffractometry, Fourier transform infrared spectroscopy, transmission electron microscopy, Raman spectroscopy, scanning electron microscopy and thermogravimetric analysis. Thin films of hcp and fcc nickel nanoparticles were prepared through a biphasic system and deposited over indium-doped tin oxide (ITO) substrates, which were electrochemically characterized and applied as glycerol amperometric sensors in NaOH medium. Parameters as the number of cycles applied and the scan rate were evaluated and indicate that hcp nickel nanoparticles are more reactive to form Ni(OH)2 and lead to more electroactive Ni(OH)2 structure. The hcp nickel nanoparticles-modified electrode showed the best sensitivity (0.258 µA L µmol(-1)) and detection limit (2.4 µmol L(-1)) toward glycerol.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA