RESUMO
OBJECTIVE: To evaluate the effect of different hydrofluoric acid concentrations and etching times on the surface, chemical composition and microstructure of lithium disilicate. MATERIAL AND METHODS: Ninety specimens of pressed lithium disilicate (LDS) were obtained (IPS e.max Press, Rosetta SP and LiSi Press). The specimens of each material were divided in two groups according to the hydrofluoric acid concentration: 5% and 10% (n = 15/group), and subdivided according to the etching time: 20, 40 and 60 s (n = 5/group). Crystalline evaluations and chemical composition were performed through x-ray diffraction (XRD) and energy-dispersive x-ray spectroscopy (EDS), respectively. Microstructural analyses were performed by scanning electron microscope (SEM), surface roughness (Ra), and material thickness removal evaluation. Thickness removal and Ra data were analyzed by ANOVA and Tukey test (p < 0.05). RESULTS: XRD demonstrated characteristic peaks of lithium disilicate crystals, lithium phosphate and of a vitreous phase for all materials. EDS identified different compositions and SEM confirmed different surface responses to acid etching protocols. Material and etching time influenced Ra and material thickness removal (p < 0.05). CONCLUSION: Hydrofluoric acid concentration and etching time affect the surface characteristics of LDS differently. LiSi Press presented higher resistance to hydrofluoric acid etching compared to e.max Press and Rosetta SP. CLINICAL SIGNIFICANCE: Applying the appropriate etching protocol is pivotal to avoid excessive material removal and to prevent jeopardize the mechanical and optical properties of the material.
Assuntos
Colagem Dentária , Ácido Fluorídrico , Ácido Fluorídrico/química , Teste de Materiais , Porcelana Dentária/química , Cerâmica/química , Propriedades de Superfície , Colagem Dentária/métodos , Cimentos de Resina/químicaRESUMO
Abstract This study verified the effect of the combination of preheated hydrofluoric acid/silane/electric current in the adhesion of the resin cement to ceramic. IPS E.max Press ceramic discs embedded in PVC rigid tubes were divided into four groups associating preheated hydrofluoric acid and silane applied with electrical current (n=10): Ha+S (Heated acid + silane); Ha+S+Ec (Heated acid + silane + electrical current); A+S (Acid + silane) and A+S+Ec (Acid + silano + electrical current). Resin cement/ceramic samples were stored in water at 37°C for 24h. After storage, they were submitted to the microshear test, fracture analysis, and contact angle at 24h or after thermocycling (10,000 cycles/5-55ºC). Bond strength data were evaluated by two-way ANOVA. For comparison between evaluation times (24h or thermocycling) was applied unpaired t-test. A significance post-hoc test of p=0.05 was assumed for analyses and graphs (GraphPad Prism 9.0 software). At 24h, the microshear strength showed similar values between Ha+S, Ha+S+Ec, and A+S+Ec groups, while A+S showed the lowest value with a statistical difference. After thermocycling, Ha+S and Ha+S+Ec were similar, as well as A+S and A+S+Ec. There was a significant difference in all groups comparing 24h (highest value) with after thermocycling (lowest value). Adhesive fracture was predominant in all groups and evaluation times. Ha+S and A+S groups showed higher contact angle values compared to the Ha+S+Ec and A+S+Ec with lower values. In conclusion, the association of preheated hydrofluoric acid/silane applied or not with electric current promoted different microshear strength values, fracture types, and contact angles in the resin cement/ceramic bond.
Resumo Este estudo verificou o efeito da combinação ácido fluorídrico pré-aquecido/silano/corrente elétrica na adesão do cimento resinoso à cerâmica. Os discos cerâmicos IPS E.max Press embutidos em tubos rígidos de PVC foram separados em quatro grupos associando ácido fluorídrico pré-aquecido e silano aplicado com corrente elétrica (n=10): Ha+S (ácido aquecido + silano); Ha+S+Ec (Ácido aquecido + silano + corrente elétrica); A+S (Ácido + silano) e A+S+EC (Ácido + silano + corrente elétrica). Amostras de cimento resinoso/cerâmica foram armazenadas em água a 37°C por 24 horas. Após o armazenamento foram submetidas ao ensaio de micro cisalhamento, análise de fratura e ângulo de contato no período de 24 horas ou após termociclagem (10.000 ciclos/5-55ºC). Os dados de resistência de união foram avaliados por ANOVA dois fatores. Para comparação entre os tempos de avaliação (24 horas ou termociclagem) foi aplicado o teste t não pareado. Foi assumida significância de 5% para análises e gráficos (software GraphPad Prism 9.0). Em 24 horas, a resistência ao micro cisalhamento apresentou valores similares entre os grupos Ha+S, Ha+S+Ec e A+S+Ec, enquanto A+S apresentou menor valor com diferença estatística. Após a termociclagem, Ha+S e Ha+S+Ec foram similares, assim como A+S e A+S+Ec. Houve diferença significativa em todos os grupos comparando 24 horas (maior valor) com após termociclagem (menor valor). A fratura adesiva foi predominante em todos os grupos e tempos de avaliação. Os grupos Ha+S e A+S apresentaram maiores valores de ângulos de contato comparados aos grupos Ha+S+Ec e A+S+Ec com valores menores. Em conclusão, a associação ácido fluorídrico pré-aquecido/silano aplicado com corrente elétrica promoveu diferentes valores de resistência ao micro cisalhamento, tipos de fratura e ângulos de contato na adesão do cimento resinoso à cerâmica.
RESUMO
Abstract The aim was to evaluate the effect of stress distribution on vertical, horizontal, and oblique forces on the tooth model after reattaching the fragments of the maxillary incisor with vertical root fracture (VRF) using different materials, by 3D finite element analysis (FEA). Tooth with a root canal, spongious, and cortical bone models were designed. VRF was modeled on a tooth with 4 different re-attachment models: Group 1: dual-cure cement (DC)+fiber reinforced composite (FRC), Group 2: DC+polyethylene fiber, Group 3: DC+glass fiber, and Group 4:DC. 100 N force was applied in 3 different directions. Maximum principal stresses (σmax) of dentin, and re-attachment materials were evaluated on colored images. The highest σmax values were on the repair materials under vertical forces for Groups 1 and 4, respectively; Groups 2 and 3 showed similarity. The highest σmax values in repair materials under horizontal and oblique forces were observed in Group 3 however the lowest σmax values in repair materials under oblique and horizontal forces were observed in Group 1. The stress values on repair materials gradually increased respectively starting from horizontal to vertical. As the elasticity modulus of the repair materials increased, the stress values on root dentin increased. Through all force directions, except vertical forces, lower stress values were observed with FRC. The fracture resistance was bigger when using solely FRC or dual-cure resin cement in comparison to fiber-supported designs. Adding polyethylene fiber to re-restorations decreased stress values compared to glass fiber addition. Therefore, when adding fibers, polyethylene fiber will be advantageous.
Resumo O objetivo foi avaliar o efeito da distribuição de estresse nas forças verticais, horizontais e oblíquas no modelo de dente após a recolocação dos fragmentos do incisivo superior com fratura radicular vertical (FRV) usando diferentes materiais, por meio da análise de elementos finitos (FEA) em 3D. Métodos: Foram projetados modelos de dentes com canal radicular, osso esponjoso e cortical. A FRV foi modelada em um dente com 4 modelos diferentes de reataque, como Grupo 1: cimento de cura dupla (DC) + compósito reforçado com fibra (FRC), Grupo 2: DC + fibra de polietileno, Grupo 3: DC + fibra de vidro e Grupo 4: DC. Foi aplicada uma força de 100 N em 3 direções diferentes. As tensões principais máximas (σmax) da dentina e os materiais de recolocação foram avaliados em imagens coloridas. Resultados: Os valores mais altos de σmax foram registrados nos materiais de reparo sob forças verticais para os Grupos 1 e 4, respectivamente; os Grupos 2 e 3 apresentaram semelhança. Os valores mais altos de σmax nos materiais de reparo sob forças horizontais e oblíquas foram observados no Grupo 3; no entanto, os valores mais baixos de σmax nos materiais de reparo sob forças oblíquas e horizontais foram observados no Grupo 1. Os valores de tensão nos materiais de reparo aumentaram gradualmente, respectivamente, começando da holizontal para a vertical. À medida que o módulo de elasticidade dos materiais de reparo aumentava, os valores de tensão na dentina da raiz aumentavam. Em todas as direções de força, exceto nas forças verticais, foram observados valores de tensão mais baixos com o FRC. Conclusões: a resistência à fratura foi maior quando se utilizou apenas FRC ou cimento resinoso de cura dupla em comparação com os designs com suporte de fibra. A adição de fibra de polietileno às restaurações diminuiu os valores de tensão em comparação com a adição de fibra de vidro. Portanto, ao adicionar fibras, a fibra de polietileno será vantajosa.
RESUMO
Abstract This study was designed to investigate the impact of access cavity designs on fracture resistance of endodontically treated maxillary first premolars. The study sample consisted of 72 intact maxillary first premolars, randomly divided into six groups (n = 12). A standardized proximal cavity preparation was prepared for all samples using standard bur. Groups I: control group with only standard proximal cavity and no endodontic access, group II: Truss access cavity, group III: Separated access to buccal and palatal canals without removal of dentine in between, group IV: Access to buccal and palatal canals with removal of dentine in between, group V: Traditional access cavity, group VI: Mesio-occlusal-distal cavity (MOD). For groups I and VI, only composite restoration was used to restore the proximal cavity, while for groups II- V, the access was prepared and endodontic treatment was performed on all teeth, then composite restoration was placed. The root canals were instrumented using nickel-titanium files, irrigated with sodium hypochlorite, and filled with AH plus sealer and gutta-percha using warm vertical condensation. All samples were then placed in an acrylic mold and underwent thermal aging for 10,000 cycles between 5 and 55°C. The samples were fixed in a universal testing machine with the long axis of the roots positioned at 20° to a load applied at a crosshead speed of 1 mm/min using a stainless steel semi-spherical indenter (Ø = 3 mm) until fracture occurred to determine the fracture resistance force in Newton. The normality test (Shapiro-Wilk) showed that data are normally distributed. Group II exhibited the highest mean fracture resistance, and group VI was the least likely to resist the fracture. No statistically significant differences between tested groups (p-value = 0.237). The MOD group showed a more unfavorable mode of fracture compared to other groups. No significant difference in fracture resistance between conservative and traditional access cavities. The missing marginal ridges, such as in MOD cavities played an important role in decreasing the fracture resistance of endodontically treated teeth.
Resumo O objetivo deste estudo foi investigar o impacto do design da cavidade de acesso na resistência à fratura de primeiros pré-molares superiores tratados endodonticamente. MÉTODOS: A amostra do estudo consistiu em 72 primeiros pré-molares superiores intactos, divididos aleatoriamente em seis grupos (n = 12). Um preparo padronizado da cavidade proximal foi realizado para todas as amostras usando broca padrão. Grupos I: grupo de controle com apenas cavidade proximal padrão e sem acesso endodôntico, grupo II: cavidade de acesso Truss, grupo III: acesso separado aos canais vestibular e palatino sem remoção de dentina entre eles, grupo IV: acesso aos canais vestibular e palatino com remoção de dentina entre eles, grupo V: cavidade de acesso tradicional, grupo VI: cavidade mesio-oclusal-distal (MOD). Para os grupos I e VI, apenas a restauração de compósito foi usada para restaurar a cavidade proximal. Já nos grupos II e V, o acesso foi preparado e o tratamento endodôntico foi realizado em todos os dentes e, em seguida, foi colocada a restauração de resina composta. Os canais radiculares foram instrumentados com limas de níquel-titânio, irrigados com hipoclorito de sódio e preenchidos com AH plus sealer e guta-percha usando condensação vertical quente. Todas as amostras foram então colocadas em molde de acrílico e submetidas a envelhecimento térmico por 10.000 ciclos entre 5 e 55°C. As amostras foram fixadas em uma máquina de teste universal com o eixo longo das raízes posicionado a 20° para uma carga aplicada a uma velocidade de cruzeta de 1 mm/min usando indentador semiesférico de aço inoxidável (Ø = 3 mm) até que ocorresse a fratura para determinar a força de resistência à fratura em Newton. RESULTADOS: O teste de normalidade (Shapiro-Wilk) mostrou que os dados são normalmente distribuídos. O grupo II apresentou a maior resistência média à fratura, e o grupo VI foi o menos propenso a resistir à fratura. Não houve diferenças estatisticamente significativas entre os grupos testados (p-valor = 0,237). O grupo MOD apresentou um modo de fratura mais desfavorável em comparação com os outros grupos. CONCLUSÕES: Não houve diferença significativa na resistência à fratura entre as cavidades de acesso conservador e tradicional. A ausência de cristas marginais, como nas cavidades MOD, desempenhou um papel importante na diminuição da resistência à fratura dos dentes tratados endodonticamente.
RESUMO
Abstract Objective This study aimed to analyze the longitudinal bond strength of a universal adhesive and chemically characterize the dentin substrate under different acid etching protocols. Methodology Dentin samples were etched with polyacrylic acid 25% (PAA) for 10 seconds (n=3) and phosphoric acid 32% (PA) for 15 seconds (n=3) and analyzed by Fourier transform infrared spectroscopy - attenuated total reflectance (FTIR-ATR) before and after treatment. For collagen degradation, samples (n=12) were divided into 3 groups: PAA, PA, and Deionized water (control), and analyzed by the quantity of solubilized type I collagen C-terminal cross-linked telopeptides and solubilized C-terminal peptide in relation to total protein concentration (ICTPtp and CTXtp) and by their ultimate tensile strength (UTS). For the adhesive interface analysis, dentin samples (n=72) were divided into 3 groups: PAA, PA, and Self-etch (SE), and subdivided into 2 groups: 24 h (baseline) and 1 year. The following tests were performed: microtensile bond strength (μTBS) (n=48), scanning electron microscopy (SEM) (n=12), and nanoleakage (n=12). Results The FTIR of PAA showed lower reduction of the peaks in the phosphate group when compared to PA. For ICTPtp, PA showed a significantly higher value. For CTXtp, PA and PAA groups failed to statically differ from each other. UTS was significantly lower for PA. For μTBS, storage time significantly affected bond strength. The results were unaffected by the etching protocol. For SEM, after 1 year, PA had little evidence of degradation in the upper third of the adhesive interface in comparison to the other groups. Nanoleakage showed no considerable silver impregnation after 1 year in the SE group. Conclusion The use of PAA prior to a universal adhesive (when compared to PA) represents a less aggressive type of etching to dentin. However, self-etching still seems to be the best option for universal adhesive systems that have functional monomers in their composition.
RESUMO
ABSTRACT Objectives: This clinical trial was conducted to evaluate the stability and failure rate of surface-treated orthodontic mini-implants and determine whether they differ from those of non-surface-treated orthodontic mini-implants. Trial Design: Randomized clinical trial with a split-mouth study design. Setting: Department of Orthodontics, SRM Dental College, Chennai. Participants: Patients who required orthodontic mini-implants for anterior retraction in both arches. Methods: Self-drilling, tapered, titanium orthodontic mini-implants with and without surface treatment were placed in each patient following a split-mouth design. The maximum insertion and removal torques were measured for each implant using a digital torque driver. The failure rates were calculated for each type of mini-implant. Results: The mean maximum insertion torque was 17.9 ± 5.6 Ncm for surface-treated mini-implants and 16.4 ± 9.0 Ncm for non-surface-treated mini-implants. The mean maximum removal torque was 8.1 ± 2.9 Ncm for surface-treated mini-implants and 3.3 ± 1.9 Ncm for non-surface-treated mini-implants. Among the failed implants, 71.4% were non-surface-treated mini-implants and 28.6% were surface-treated mini-implants. Conclusion: The insertion torque and failure rate did not differ significantly between the groups, whereas the removal torque was significantly higher in the surface-treated group. Thus, surface treatment using sandblasting and acid etching may improve the secondary stability of self-drilling orthodontic mini-implants. Trial registration: The trial was registered in the Clinical Trials Registry, India (ICMR NIMS). Registration number: CTRI/2019/10/021718
RESUMO Objetivos: Este ensaio clínico foi conduzido para avaliar a estabilidade e a taxa de falha de mini-implantes ortodônticos com superfície tratada, e determinar se elas diferem das dos mini-implantes ortodônticos sem superfície tratada. Desenho do estudo: Ensaio clínico randomizado com desenho de boca dividida. Instituição: Department of Orthodontics, SRM Dental College, Chennai/India. Participantes: Pacientes que necessitavam de mini-implantes ortodônticos para retração anterior em ambas as arcadas. Métodos: Mini-implantes ortodônticos autoperfurantes, cônicos, de titânio com ou sem tratamento de superfície, foram colocados em cada paciente, seguindo um desenho de boca dividida. Os torques máximos de inserção e de remoção foram medidos para cada mini-implante, usando um torquímetro digital. As taxas de falha foram calculadas para cada tipo de mini-implante. Resultados: O valor médio do torque máximo de inserção foi de 17,9 ± 5,6 Ncm para mini-implantes com superfície tratada e 16,4 ± 9,0 Ncm para mini-implantes sem superfície tratada. O valor médio do torque máximo de remoção foi de 8,1 ± 2,9 Ncm para mini-implantes com superfície tratada e 3,3 ± 1,9 Ncm para mini-implantes sem superfície tratada. Entre os implantes que falharam, 71,4% eram mini-implantes sem superfície tratada e 28,6% eram mini-implantes com superfície tratada. Conclusão: O torque de inserção e a taxa de falha não diferiram significativamente entre os grupos; porém, o torque de remoção foi significativamente maior no grupo com superfície tratada. Assim, o tratamento de superfície com jateamento e condicionamento ácido pode melhorar a estabilidade secundária dos mini-implantes ortodônticos autoperfurantes. Registro do estudo: Esse estudo foi registrado no Clinical Trials Registry, Índia (ICMR NIMS). Número de registro: CTRI/2019/10/021718
RESUMO
ABSTRACT Objective: This study assessed whether the use of a silane coupling agent influence the bond strength of two universal adhesives to ceramic or resin CAD/CAM blocks. Methods: Forty-eight samples were obtained from each resin nano-ceramic hybrid block (RCBs) and lithium disilicate ceramic blocks (LD). Samples were treated with silane with MDP (Monobond - S-MDP), silane without MDP (Prosil - PS), and no silane application (Control - Ctr) followed by universal adhesive with silane (UAS) and without silane (UA) (n=8). Three polyurethane tubes (1.5 mm of internal diameter) were positioned in each sample treated surface and filled with a dual cured resin cement. Bond strength was assessed by microshear bond strength test and failure analysis was performed for all samples. Results: For the RCBs, UAS presented the highest bond strength values (p=0.004). Silane application was not significant in bond strength values (p=0.444). For LD, silane application was significant in bond strength values (p<0.001), but the adhesive was not (p=0.066). Failure analysis showed high prevalence of adhesive failures for both substrates. Conclusion: A silane-containing universal adhesive promoted the best bond strength results to the resin nano-ceramic hybrid block. For bonding to a glass-ceramic CAD/CAM material, additional silane (without MDP) application presented the best results.
RESUMO Objetivo: Este estudo avaliou se o uso de um agente de união silano influencia na resistência de união de dois adesivos universais a blocos CAD/CAM cerâmicos ou resinosos. Métodos: Quarenta e oito amostras foram obtidas de blocos resinosos (RCBs) e cerâmicos de dissilicato de lítio (LD). As amostras foram tratadas com silano contendo: MDP (Monobond - S-MDP), silano sem MDP (Prosil - PS) ou sem aplicação de silano (Control - Ctr) seguido de adesivo universal com silano (UAS) ou sem silano (UA) (n=8). Três tubos de poliuretano (1,5 mm de diâmetro interno) foram posicionados em cada superfície tratada da amostra e preenchidos com um cimento resinoso dual. A resistência de união foi avaliada pelo teste de microcisalhamento e a análise de falha foi realizada para todas as amostras. Resultados: Para os RCBs, UAS apresentou os maiores valores de resistência de união (p=0,004). A aplicação de silano não foi significativa nos valores de resistência adesiva (p=0,444). Para LD, a aplicação de silano foi significativa nos valores de resistência de união (p<0,001), mas o adesivo não (p=0,066). A análise de falhas mostrou alta prevalência de falhas adesivas para ambos os substratos. Conclusão: O adesivo universal contendo silano promoveu os melhores valores de resistência adesiva ao bloco de resina. Para o bloco cerâmico, a aplicação adicional de silano (sem MDP) apresentou melhores resultados.
RESUMO
ABSTRACT Objective: To find out what the acid-base resistant zone (ABRZ) is and the mechanism of its formation. Material and Methods: This systematic review was based on the search of laboratory studies in which selfetching adhesive systems were used. The electronic database PubMed was used for the search. The search began on August 2021 and ended on June 2022. We have analyzed the materials and methods of each research and entered them in the appropriate tables to give a clearer assessment of the obtained results. Results: This systematic review included 15 full-text articles published from 2011 to 2019. The ABRZ is formed on both dentine and enamel. On dentine, the ABRZ is formed only when using self-etching adhesive systems; on the enamel, on the contrary, the step of preliminary etch and rinse contributes to the formation of a thicker ABRZ. The functional monomer MDP and fluorine increase the thickness of the ABRZ and provide a hybrid layer /ABRZ boundary without defects and erosions. Conclusion: Self-etching adhesive systems ensure the creation of an ABRZ resistant to acid-base tests. This phenomenon can provide the resistance of tooth tissues to demineralization, and therefore increase their resistance to caries.
Assuntos
Condicionamento Ácido do Dente , Colagem Dentária/métodos , Adesivos Dentinários/químicaRESUMO
RESUMEN Introducción: Buscando satisfacer la demanda con procedimientos adhesivos más rápidos, menos sensibles a la técnica y facilidad de uso, se han desarrollado los adhesivos universales, que brindan al profesional la opción de seleccionar la estrategia de adhesión con diferentes modos de grabado, ya sea con grabado y enjuague, autograbado o grabado selectivo. Debido a la poca información existente, se han generado dudas sobre el rendimiento, propiedades y la aplicación de una técnica adhesiva adecuada sobre los tejidos dentales. Objetivo: Determinar el nivel de adhesión con el uso de adhesivos universales en modo de grabado y enjuague y autograbado. Métodos: Se realizó una revisión de la literatura, a través de la búsqueda electrónica en las bases de datos: SciELO, Scopus, PubMed, Springer y EBSCO. Inicialmente se seleccionaron por título y resumen, artículos duplicados se consideraron solo una vez, se incluyeron artículos de acceso libre y pagos, escritos en idioma español e inglés, publicados desde el año 2015, de los cuales 39 artículos fueron seleccionados para el estudio. Conclusiones: El uso de adhesivos universales sobre dentina presenta un nivel de adhesión mayor cuando se aplica en modo de autograbado. La aplicación activa del adhesivo universal en esmalte mejora la fuerza y resistencia de unión. El nivel de adhesión en el esmalte es mayor cuando se aplica en modo de grabado y enjuague. La resistencia inicial y por fatiga del adhesivo, no mejora con los tiempos prolongados del grabado ácido.
ABSTRACT Introduction: universal adhesives have been developed to satisfy the demand with faster adhesive procedures, less sensitive to the technique and ease of use, which offer the professional the option of selecting the adhesion strategy with different etching modes, either with etch-and-rinse, self-etch or selective etching ones. Doubts have been generated about the performance, properties and application of an adequate adhesive technique on dental tissues due to the little existing information. Objective: to determine the level of adhesion with the use of universal adhesives in etch-and-rinse and self-etch modes Methods: an electronic search of the literature was carried out in SciELO, Scopus, PubMed, Springer and EBSCO databases. Initially, articles were selected by title and abstract, duplicate ones were considered only once, free and paid access articles, written in Spanish and English and published since 2015 were included; 39 of them were selected for the study. Conclusions: the use of universal adhesives on dentin presents a higher level of adhesion when applied in self-etch mode. The active application of the universal adhesive improves the enamel bond strength. The level of adhesion on the enamel is higher when applied in etch-and-rinse. The initial fatigue resistance of the adhesive does not improve with prolonged acid etching times.
Assuntos
Condicionamento Ácido do Dente , Colagem Dentária , Adesivos DentináriosRESUMO
Aim: Recent reports indicate that deproteinization of acid-etched dentin surface can extend penetration depth of adhesive agents. The main goal of the present research was to investigate the deproteinization effect of Nd:YAG and diode 940 lasers on acid-etched dentin and microleakage grade in class V composite restorations. Methods: 36 extracted human premolar teeth were selected to make standard buccal and lingual class V cavities. These samples were randomly split into three sub-groups: 1.Control group, in which composite was applied for restoration after etch and bonding process without deproteinization; 2.Nd:YAG laser group, in which the teeth were deproteinized with Nd:YAG laser after etching and painting internal surfaces of cavities with Van Geison stain and then composite restorations applied just as control group; 3.Diode laser group, in which the process was similar to Nd:YAG laser group, but instead, diode 940 laser was irradiated. The teeth were bisected into two equal longitudinal buccal and lingual halves. Marginal microleakage of samples was scored by using a stereomicroscope. Kruskal- Wallis, Mann-Whitney U and Fisher's statistical tests were employed for analysis of the obtained data. Results: A significant reduction in marginal microleakage was observed for both groups treated with laser (Nd:YAG and diode 940)compared to control (p=0.001 & p=0.047). There was no significant difference in marginal microleakage between Nd:YAG laser and diode 940groups (P = 0.333). Conclusion: Nd:YAG and diode 940 laser deproteinization of acid-etched dentin decreased the marginal microleakage of in-vitro class V resin composite restorations
Assuntos
Humanos , Condicionamento Ácido do Dente , Adesivos Dentinários , Infiltração Dentária , LasersRESUMO
INTRODUCTION: The most used product for surface acid conditioning for enamel is 37-40% phosphoric acid, which promotes greater mechanical retention. AIM: The objective of this study was to compare the shear bond strength (SBS) of brackets bonded to bovine enamel with different acid conditioning protocols and to analyze the surface morphology. MATERIALS AND METHODS: 169 teeth (n = 13) were divided into 4 groups: control group without conditioning (G1), Dental Gel 37% phosphoric acid (Dentsply) (G2), Ultra Etch 35% (Ultradent) (G3) and Attaque gel 37% (Biodinâmica) (G4). Groups G2, G3 and G4 were subdivided according to the conditioning time into: 10 s (a), 15 s (b), 30 s (c) and 60 s (d). The superficial enamel morphology (n = 3) was analyzed using a scanning electron microscopy (SEM) to analyze the depth of the microporosities. The samples were submitted to the shear test (SBS) with the aid of a universal testing machine (INSTRON) with a speed of 1 mm/min. The enamel after debonding was analyzed to determine the adhesive remnant index (ARI) in a stereoscopic magnifying glass. STATISTICAL ANALYSIS USED: The SBS data were analyzed using two-way ANOVA. ARI data were analyzed using generalized linear models and SEM measurements were analyzed using Kruskal Wallis and Dunn tests. The 95% significance level was used. RESULTS: The SBS within G2, G3 and G4 ranged from 11.11 to 12.66 MPa. ARI score 3 was observed in 35% of the samples. The samples analyzed in the SEM showed microporosity depth rangingfrom 1.28 to 2.48 µm. CONCLUSIONS: There was no difference between the acids and times evaluated for SBS. The ARI analysis showed that the studied acids provide protection to the enamel surface, keeping the adhesive attached to the buccal surface after debonding. The increase in conditioning time is directly proportional to the deterioration of the prismatic and interprismatic content.
RESUMO
El secado es uno de los factores clave para lograr una adhesión micromecánica exitosa en la dentina con los sistemas adhesivos de grabado independiente. El objetivo de este trabajo fue comparar los residuos remanentes luego de cuatro procedimientos diferentes de secado en preparaciones ex vivo en dentina. Se utilizaron cinco terceros molares ex-vivo, en cada uno de los cuales se realizó una preparación dentinaria en piso y paredes con al menos un socavado. Las unidades experimentales fueron almacenadas en solución fisiológica durante 7 días. Las distintas técnicas de secado (G1- G8) se aplicaron, luego de que las preparaciones fueron tratadas con gel de ácido fosfórico al 37% (Blue Gel etch Megadental) durante 15s y lavadas con jeringa y agua a presión durante 15s (Técnica de Grabado Ácido o TGA), de la siguiente manera: algodón común (Condesa) (G1), papel tisú (Achiss) cortado a mano (G2) y con tijera (G3), esponja (Sharpys) (G4), papel tisú (Simplicity) cortado a mano (G5)(AU)
Assuntos
Resíduos , Dentina/efeitos dos fármacos , Condicionamento Ácido do Dente , Colagem Dentária , Abrasão Dental por Ar , Preparo da Cavidade DentáriaRESUMO
Abstract: Objective: To evaluate non-carious cervical lesions (NCCLs) restored with different adhesion strategies. Methodology: This is a prospective, randomized, double-blind, split-mouth study. An adhesive restorative system (Single Bond Universal/Filtek Z350XT - SBU) was evaluated both without and with selective enamel conditioning (E-SBU), resin-modified glass-ionomer cements (Vitremer; RMGIC), and ethylenediaminetetraacetic acid pretreatment (EDTA; E-RMGIC). In total, 200 restorations, placed in 50 patients, were evaluated at baseline and at a 3-year follow-up using the modified United States Public Health Service (USPHS) criteria. Data were analyzed using the two-proportion equality test, multinomial logistic regression, Wilcoxon test, and Kaplan-Meier survival curves. Results: In total, 42 (84%) patients returned for the 3-year follow-up. SBU showed restoration losses statistically different from RMGIC. Retention was also statistically different in SBU between baseline and the 3-year follow-up. Marginal defects and surface texture were statistically significant for all groups in the period studied, except for the surface texture of SBU and the marginal integrity in E-RMGIC. We observed no statistically significant difference in wear, secondary caries, anatomical form, surface staining, and color over time. Recession degree was the only factor to influence retention rates. Cumulative survival (%) was 89, 98, 98, and 95.3, for SBU, SE-SBU, RMGIC, and E-RMGIC, respectively, without significant differences among them. There was a statistically significant difference between survival curves; however, multiple comparison procedures found no statistical differences. Conclusion: Selective enamel etching affected the retention of non-carious cervical restorations. Adhesion using EDTA and resin-modified glass-ionomer cements delayed marginal defects over time. The degree of gingival recession influenced retention rates. Resin composite restorations showed initial marginal defects, and ionomer restorations, reduced surface luster. EDTA pre-treatment followed by resin-modified glass-ionomer cements may be a promising adhesion strategy for NCCL restorations.
Assuntos
Humanos , Cárie Dentária/terapia , Restauração Dentária Permanente , Estudos Prospectivos , Seguimentos , Adaptação Marginal Dentária , Resinas Compostas , Cimentos de Resina , Cimentos de Ionômeros de Vidro/uso terapêuticoRESUMO
Introduction: This study aimed to evaluate the effect of dentin surface treatment with 37% phosphoric acid or 17% ethylenedia-minetetraacetic acid (EDTA) before Internal Bleaching with 35% hydrogen peroxide using the walking bleach technique. Material and Methods: This experimental in vitro study used 66 human premolars extracted for orthodontic reasons, which were debrided, endodontically prepared, and pigmented with chromogens derived from blood decomposition. The samples were randomly divided into three groups (n=22). Group A: bleaching agent without dentin conditioning; group B: bleaching agent in dentin conditioned with phosphoric acid 37%; group C: bleaching agent in dentin conditioned with 17% EDTA. 4 applications of bleaching agent were used with a separation of 4 days between each session. The initial color (baseline) and after each application was determined by spectrophotometry, recording the CIE L*a*b* values and the total color variation between the initial parameters and the different evaluation times. Results: Data were statistically analyzed with the Wilcoxon test. This showed statistically significant differences for the total variation of the color between the study groups, with the control group in no case inferior to the rest. Conclusion: The application of 37% phosphoric acid increased the effectiveness of the bleaching agent when compared to 17% EDTA. However, these did not increase the effectiveness compared to the application of the bleaching agent without a previous dentin surface treatment.
Introducción: El objetivo de este estudio fue evaluar el efecto del tratamiento de superficie dentinaria con ácido fosfórico al 37% o EDTA al 17% previo al blanqueamiento Interno con peróxido de hidrógeno al 35% por medio de la técnica Walking Bleach. Material y Métodos:Para este estudio experimental in vitro, se utilizaron 66 premolares humanos extraídos por indicación ortodóncica, los cuales fueron desbridados, preparados endodónticamente, y pigmentados con cromógenos derivados de la descomposición sanguínea. Las muestras fueron divididas aleatoriamente en 3 grupos (n=22). Grupo A: agente blanqueador sin acondicionamiento dentinario, grupo B: agente blanqueador en dentina acondicionada con ácido fosfórico 37% y grupo C: agente blanqueador en dentina acondicionada con EDTA 17%. Se utilizaron 4 aplicaciones de agente blanqueador con una separación de 4 días entre cada sesión. El color inicial (baseline) y tras cada aplicación fue determinado mediante espectrofotometría, registrando los valores CIE L*a*b* y la variación total de color entre los parámetros iniciales y los diferentes tiempos de evaluación. Resultados: Los datos fueron analizados estadísticamente con la prueba de Wilcoxon, arrojando diferencias estadísticamente significativas para la variación total del color entre los grupos de estudio, siendo en ningún caso el grupo control inferior al resto. Conclusión: La aplicación de ácido fosfórico al 37% aumenta la eficacia del agente blanqueador al compararlo con el EDTA 17%, sin embargo, no aumentan la eficacia respecto a la aplicación del agente blanqueador sin un tratamiento de superficie dentinaria previo.
Assuntos
Humanos , Ácido Edético/química , Cor , Esmalte Dentário/química , Dentina/química , Peróxido de Hidrogênio/química , Espectrofotometria , Dente Pré-Molar , Técnicas In Vitro , Chile , Ensaio ClínicoRESUMO
BACKGROUND: There are different etching gels available, which have different composition, different pH, and different viscosity, and there is little information in the literature comparing all these products. OBJECTIVE: To evaluate the mean microshear bond strength and morphological characteristics of tooth enamel by evaluating different phosphoric acids combined with a universal adhesive system. MATERIALS AND METHODS: Eighty-four enamel samples were used, which were divided according to the acid conditioning: G1: Scotchbond Etchant (3M Oral Care), G2: Ultra-Etch (Ultradent), G3: Eco-Etch (IvoclarVivadent), G4: ETCH-37 with BAC (Bisco), G5: Etching gel (Densell), G6: Condac 37 (FGM), and G7: Scotchbond Universal Adhesive (3M Oral Care) in self-etch mode. For the adhesive procedure, Scotchbond Universal Adhesive was the one used as indicated the manufacturer's instructions, 0.9-mm-diameter resin cylinders were placed. The microshear bond strength test was performed after being stored for 24 hours in water. The morphological characteristics of tooth enamel were analyzed using the Raman confocal microscope alpha300RA. The analysis of variance (ANOVA) test and Tukey post-test were used to analyze the differences between the groups. RESULTS: The mean microshear bond strength values obtained for groups 1, 4, 5 were significantly greater than groups 2, 3, 6 and 7 (p < .05). All groups presented demineralization after the application of the etching acid, and few signs of demineralization were evident in group 7. CONCLUSIONS: Acid-etching with ETCH-37 with BAC, Etching gel, and Scotchbond Etchant improved the adhesive strength in the enamel using an universal adhesive, and acid-etching with Condac 37, Ultra-Etch, and Eco-Etch provides similar adhesive strength values to self-etch mode of universal adhesive. CLINICAL SIGNIFICANCE: All acid etchants should be considered as different. The test confirms that enamel etching prior to the application of a universal adhesive system depends on the selected acid etchand product.
Assuntos
Colagem Dentária , Ácidos Fosfóricos , Condicionamento Ácido do Dente , Cimentos Dentários , Esmalte Dentário , Adesivos Dentinários , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de SuperfícieRESUMO
BACKGROUND: When a phosphoric acid is used, before applying an adhesive system, it is known that obtaining an effective adhesion to the root canal walls is a challenge. The aim of the present study was to evaluate the influence of phosphoric acid viscosity and application mode on the push-out bond strength (BS) values of fiberglass post to root dentin. The conditioning pattern on the root dentin was also evaluated. MATERIALS AND METHODS: The roots of 44 endodontically treated premolars were divided into 4 groups, of eleven teeth each, according to the combination of the main factors: phosphoric acid viscosity (liquid or gel) and application mode (passive or sonic). After application of the two-step etch-and-rinse adhesive system, the fiberglass posts were cemented with a dual-cure resin-cement. Roots were sectioned transversely into six 1-mm slices for push-out BS test at 0.5 mm/min. Some roots of each group were selected for evaluation of the conditioning pattern by scanning electron microscopy. BS results (three-way ANOVA and Tukey's test) and the conditioning pattern (Kruskal-Wallis test and Mann-Whitney test) were statistically evaluated (α= 0.05). RESULTS: The highest BS value was observed with a liquid phosphoric acid under sonic application mode (p < 0.05), being all other groups similar to one another (p < 0.05). Also, the highest BS value was observed in the cervical third, followed by the medium and the apical thirds (p < 0.05). The sonic application produced better smear layer removal and opening of dentinal tubules for both viscosities (p = 0.015). CONCLUSION: A better bonding of fiberglass posts to root canals can be achieved when the post spaces are conditioned with a liquid phosphoric acid under sonic application.
RESUMO
Abstract The aim of this study was to investigate the influence of shortening of etching time for dentin on the restoration survival after selective carious tissue removal in primary molars. This two-arm randomized clinical trial included sixty-two subjects (5-8 year-old) and 100 primary molars presenting moderate dentin carious lesions on occlusal surface. The sample was randomly assigned into groups previously to adhesive application (Adper Single Bond 2; 3M ESPE): etching time recommended by manufacturer (15 s) or reduced (7 s). Resin composite (Filtek Bulk Fill Posterior Restorative; 3M ESPE) was inserted in a single increment for all restorations. Restorations were evaluated at 1, 6, 12, and 18 months using FDI criteria. Survival estimates for restorations' longevity were evaluated with Kaplan-Meier method. Multivariate Cox regression analysis with shared frailty was used to assess the factors associated with failures (p < 0.05). The etching time did not influence the restorations' survival (HR 0.35 95%CI 0.11-1.12; p = 0.06). Mean estimated time of survival was 17.6 months (95%CI, 17.2-17.9). The survival rates at the 18-month follow-up were 75.7% and 91.4% (AFR: 16.9% and 5.7%) when primary dentin was acid etched for 15 and 7 s, respectively (log-rank p = 0.06). In conclusion, the etching time for dentin did not influence the clinical behavior of adhesives restorations. However, there was a tendency for better clinical outcome when using etching time of 7 s.
Assuntos
Dente Decíduo , Adesivos Dentinários , Resinas Compostas , Restauração Dentária Permanente , Dentina , Dente MolarRESUMO
Introduction: Microleakage has been reported to cause dentin hypersensitivity because of the passage of bacteria and their products through the restoration-tooth interface and is one of the main reasons for replacement of restorations. CO2 laser can be used for treatment of dentin hypersensitivity. Thus, this study aimed to evaluate in vitro the microleakage in composite restorations following surface pretreatment with acid etching and CO2 laser. Methods: Twelve human caries-free primary molars were selected. Class II cavities were prepared on occlusal mesial and occlusal distal surfaces. Specimens were randomly divided into four groups (n=6): Group 1 (G1) - 37% phosphoric acid gel etching + Beautiful-Bulk Restorative - Giomer (Shofu Inc); Group 2 (G2) - 37% phosphoric acid gel etching + SDR Bulk-Fill Flow (Dentsply); Group 3 (G3) - CO2 laser irradiation + Beautiful-Bulk Restorative - Giomer (Shofu Inc); Group 4 (G4) - CO2 laser irradiation + SDR Bulk-Fill Flow (Dentsply). Surfaces were restored with bonding agent (Natural Bond DE, DFL). Specimens were cut longitudinally and immersed in 0.5% methylene blue solution for 4 hours. Microleakage scores were assessed under a magnifying glass at x3,5 and qualitatively analyzed by scanning electron microscope (SEM). Data were analyzed using nonparametric Wilcoxon test (P < 0.05). Results: Scores prevailed between 0 and 2, however, no statistically significant difference was found among the groups (P = 0.05). Conclusion: It could be concluded that all composite resins bulk fill did not show significant difference among them regarding microleakage using either CO2 laser or 37% phosphoric acid etching.
RESUMO
The aim of this study was to evaluate the shear bond strength of orthodontic tubes adhered to ceramics with the Transbond™ XT bonding resin (3M, Maplewood, MN, USA) while varying the surface treatment. Then, the adhesive remaining index (ARI) was verified, and the representative fracture patterns were evaluated via scanning electron microscopy. Forty-eight zirconia blocks were divided into three groups, varying the number of layers of the 10-methacryloyloxy-decyl dihydrogen phosphate (MDP) primer: one, two, or three applications. In addition, 16 lithium disilicate IPS E.max ceramic disks (Ivoclar Vivadent, Schaan, Liechtenstein) were conditioned with 10% hydrofluoric acid for 20 s and underwent a single-layer primer application regimen. The four groups were further stratified to undergo bond testing after either 24 h (control) or 5000 cycles in a thermocycling machine. A shear bond strength test was performed (0.5 mm/min), and the MPa values obtained were submitted to a two-way analysis of variance and Tukey's test. There was no statistical difference among the control group ceramics that received the varying surface treatments. After thermocycling, it was verified that both the E.max disks and the zirconia ceramics with three primer applications obtained the highest bond strength values. In the 24 h groups, a total displacement of the resin from the orthodontic tubes was observed (ARI of 1). After thermocycling, the highest prevalence of an ARI of 5 (adhesive failure) was observed among the zirconia ceramics with single-coat primer application, followed by those with triple-coat primer application (mixed failure). Three applications of the MDP-containing ceramic primer achieved the best result in the present study. Zirconia surface should be treated with three coats of MDP primer to achieve a level of bond strength similar to silica-rich phase ceramic.
RESUMO
Objetivos: O condicionamento da superfície dos tecidos dentários duros com ácido fosfórico 35% é normalmente utilizado para fornecer retenção micromecânica para adesivos odontológicos. Quando lavado da superfície, o ácido pode gerar gosto amargo e desagradável ao paladar do paciente. O objetivo deste estudo foi analisar o efeito da adição de um agente aromatizante à composição do gel de ácido fosfórico 35% e investigar se existe alteração de características fundamentais deste material, como sua capacidade de desmineralizar a superfície dentária. Métodos: Além de um grupo controle (sem flavorizante), foram testados grupos de ácido fosfórico 35% com a adição de 0,5% ou 3% do aromatizante (Aroma Abacaxi Pó; Bio Green Ingredients). Foram realizadas análises de viscosidade, estabilidade do pH e de desmineralização da superfície de esmalte condicionada por microscopia eletrônica de varredura, além de teste de resistência de união ao esmalte por microcisalhamento. Resultados: Apesar dos grupos apresentarem pequenas diferenças entre si, nenhuma das alterações se mostrou significativa, exceto o aumento da viscosidade do gel contendo 3% do aromatizante. Conclusões: A adição de agente aromatizante ao gel condicionador de ácido fosfórico 35% parece ser alternativa viável para reduzir os problemas relacionados ao contato com o sabor desagradável do material, uma vez que não promoveu alteração negativa significativa nas características e comportamento do ácido(AU)
Objectives: Etching of dental hard tissues surfaces with 35% phosphoric acid is usually used to provide micromechanical interlocking with dental adhesives. When washed from the surface, the acid can cause a bitter taste unpleasant to the patient. The aim of this study was to analyze the effect of the addition of a flavoring agent to 35% phosphoric acid gel and investigate whether there is change in the fundamental characteristics of this material, including its ability to demineralize dental surfaces. Methods: In addition to a control group (without flavoring agent), groups were tested with the addition of 0.5% or 3% of the flavoring compound (pineapple flavor powder, Bio Green Ingredients) to 35% phosphoric acid. Analyses of viscosity, pH stability and demineralization of enamel surfaces by scanning electron microscopy were carried out, as well microshear bond strength to enamel. Results: Although the groups had minor differences among themselves, none of the changes were significant, except the increased viscosity of the gel containing 3% of the flavoring agent. Conclusions: The addition of flavoring agent to 35% phosphoric acid gel conditioner seems to be a viable alternative to reduce the problems related to contact with the unpleasant taste of the material, since it promoted no negative changes in the characteristics and behavior of the acid(AU)