1.
Odovtos (En linea) ; 25(1)abr. 2023.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1422190

RESUMO

Dental fluorosis can cause changes in the enamel surface, conditioning its functionality and esthetics. The application of dental adhesives is a treatment option; however, their use on fluorotic teeth can result in limitations. The aim of this study was to compare the shear bond strength of two different adhesives, one with 10-MDP and one without 10-MDP, in different degrees of dental fluorosis.This is an in vitro study on dental enamel samples, a total of 180 samples with the inclusion criteria were treated, randomly divided into two groups of 90, according to the type of dental adhesive, where each group was again divided into three groups of 30 samples, representing different degrees of dental fluorosis according to the Thylstrup-Fejerskov index (Group I: TF1 and TF2; Group II: TF3; Group III: TF4). Normality tests, two-factor ANOVA, and post-hoc tests were used to determine differences between the groups, with a significance level of 95%. As results, a statistically significant difference was shown between the use of dental adhesive with 10-MDP and the three groups of dental fluorosis (p=0.011), in addition, a Tukey post-hoc test on the groups treated with 10-MDP adhesive revealed a statistically significant difference between group I versus group II, and group I versus group III, (p=<0.05). It is concluded that the use of adhesive systems with 10-MDP presents a better shear bond strength on enamel with dental fluorosis grades I and II in the Thylstrup-Fejerskov index.


La fluorosis dental puede ocasionar cambios en la superficie del esmalte, condicionando su funcionalidad y estética, la aplicación de adhesivos dentales es una opción de tratamiento, sin embargo, su uso en dientes fluoroticos puede resultar en limitaciones. El objetivo de este estudio consistió en comparar la fuerza de adhesión a la cizalladura de dos diferentes adhesivos, uno con 10-MDP y otro sin 10-MDP, en diferentes grados de fluorosis dental. Se trata de un estudio in vitro en muestras de esmalte dental, un total de 180 muestras con los criterios de inclusión fueron tratadas, aleatoriamente divididas en dos grupos de 90, de acuerdo al tipo de adhesivo dental, donde cada grupo fue dividido nuevamente en tres grupos de 30 muestras, representando diferentes grados de fluorosis dental según el índice de Thylstrup- Fejerskov (Grupo I: TF1 y TF2; Grupo II: TF3; Grupo III: TF4). Para determinar diferencias entre los grupos se utilizaron pruebas de normalidad, ANOVA de dos factores, y pruebas post-hoc, con un nivel de significancia de 95%. Como resultados, se mostró una diferencia estadísticamente significativa entre el uso de adhesivo dental con 10- MDP y los tres grupos de fluorosis dental (p=0.011), además, una prueba post hoc de Tukey sobre los grupos tratados con adhesivo 10-MDP revelaron una diferencia estadísticamente significativa entre el grupo I frente al grupo II, y el grupo I frente al grupo III, (p=<0.05) Se concluye que el uso de sistemas adhesivos con 10-MDP presentan una mejor resistencia de adhesión al cizallamiento en esmalte con grados de fluorosis dental I y II en el índice de Thylstrup-Fejerskov


Assuntos
Adesivos Dentinários/uso terapêutico , Fluorose Dentária/diagnóstico , Cimentos de Resina
2.
Materials (Basel) ; 15(15)2022 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-35955383

RESUMO

Bonding to different dental restorative materials is challenging. This study aimed to evaluate the effect of a 10-MDP-based dentin adhesive on the shear bond strength (SBS) of self-adhesive resin cement (RC) to implant abutment materials. One hundred and twenty specimens were obtained from zirconia (ZO), cobalt-chromium alloy (CoCr), and commercially pure titanium (Ti), which were treated as follows (n = 10): control group-non-treated (CG), 10-MDP-based dentin adhesive (SB), light-cured SB (SB-LC), and zirconia primer (ZP). Blocks of RC were buildup and, after 24 h, were tested for bond strength. Data of SBS (MPa) were submitted to two-way ANOVA and Tukey test (α = 0.05). There was no difference in SBS among materials for CG and ZP, higher SBS were recorded for Ti SB and Ti SB-LC compared to ZO upon the same surface treatments. For the comparisons among treatments, SB-LC showed the highest SBS for CoCr. For ZO and Ti, higher SBS were recorded with SB and SB-LC. No cohesive failures were observed. It was concluded that the surface treatment with 10-MDP-based materials increased the bond strength of the resin cement to abutment materials, which showed to be material dependent.

3.
Rev. Fac. Odontol. (B.Aires) ; 37(87): 25-33, 2022. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1537886

RESUMO

La Odontología Restauradora contemporánea no puede concebirse sin la adhesión de los materiales restauradores a las estructuras dentarias. En mu-chos procedimientos restauradores, no sólo el esmal-te sino también la dentina se encuentra involucrada, por lo tanto, la adhesión a esta última juega un rol cla-ve en el éxito clínico. No obstante, todavía supone un gran desafío lograr una adhesión estable y predeci-ble en el tiempo. El propósito del presente artículo es analizar las características principales de la dentina como sustrato adhesivo y describir los sistemas ad-hesivos actuales y sus mecanismos de acción (AU)


Contemporary Restorative Dentistry cannot be conceived without the adhesion of restorative materials to dental structures. In many restorative procedures not only the enamel, but also the dentin is involved, therefore dentin bonding plays a key role in their success. However, it is still a great challenge to achieve stable and predictable dentin bonding over time. The aim of this article is to analyze the main characteristics of dentin as an adhesive substrate and to describe current adhesive systems and their bonding mechanisms (AU)


Assuntos
Adesivos Dentinários/classificação , Dentina/efeitos dos fármacos , Dentina/ultraestrutura , Polímeros/classificação , Condicionamento Ácido do Dente/métodos , Desmineralização do Dente/fisiopatologia , Resinas Compostas/química , Metilmetacrilato/química , Restauração Dentária Permanente/tendências
4.
Rev. odontol. UNESP (Online) ; 48: e20190083, 2019. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1043176

RESUMO

Abstract Introduction Modern dentistry is reflected in the insertion of new materials with different adhesion forms in dental structures, such as the Universal adhesive system. Objective To evaluate the bond strength of the universal dentin adhesive system, in the form of self-etching and conventional application, compared with a simplified conventional adhesive system, in two distinct periods: 1 week and 6 months. Material and method 48 bovine incisors separated into 6 groups, stored for 7 days, were selected. Worn out the buccal enamel until dentin exposure. Adper Single Bond 2 (3M Espe) or SingleBond Universal (3M Espe) adhesives were applied, and catheters filled with Opallis Flow (FGM) composite were placed. After photoactivation, the catheters were removed and the specimens (n ​​= 48), stored in distilled water at 37 °C for one week and six months, were exposed. The specimens were fixed to a universal testing machine (EMIC DL 2000) with a speed of 0.5 mm / min. Bond strength (BS) was calculated in MPa, and data were statistically analyzed by Anova and Tukey test at 5% significance level. Result For Adper Single bond, the BS was equivalent in the times tested; for Universal conventional and self-conditioning time influenced the BS, with a decrease in the results. At 1 week, all stickers were different from each other, with higher BS for Universal conventional mode, followed by universal self-etching mode and then Adper Single bond. Conclusion The best results were achieved with universal adhesive in conventional mode for both tested times.


Resumo Introdução A odontologia moderna é refletida na inserção de novos materiais com diferentes formas de adesão nas estruturas dentárias, como o sistema adesivo Universal. Objetivo Avaliar a resistência adesiva do sistema adesivo universal em dentina, na forma de aplicação auto condicionante e convencional, comparando com um sistema adesivo convencional simplificado, em dois períodos distintos: 1 semana e 6 meses. Material e método Foram selecionados 48 incisivos bovinos separados em 6 grupos, armazenados por 7 dias. Desgastado o esmalte vestibular, até exposição da dentina. Aplicaram-se os adesivos Adper Single Bond 2 (3M Espe) ou SingleBond Universal (3M Espe), e sobre este, posicionados cateteres preenchidos com o compósito Opallis Flow (FGM). Após fotoativação, removeram-se os cateteres e expuseram-se os corpos de prova (n=48), armazenados em água destilada a 37 °C por uma semana e seis meses. Os corpos de prova foram fixados uma máquina universal de ensaios (EMIC DL 2000), com velocidade de 0,5 mm/min. A resistência de união (RU) foi calculada em MPa, e os dados foram analisados estatisticamente pela Anova e pelo teste de Tukey ao nível de 5% de significância. Resultado Para Adper Single bond, a RU foi equivalente nos tempos testados; para Universal modo convencional e autocondicionante o tempo influenciou na RU, havendo um decréscimo nos resultados. Em 1 semana, todos os adesivos foram diferentes entre si, com maior RU para Universal modo convencional, seguido por universal modo autocondicionante e então pelo Adper Single bond. Conclusão O melhor desempenho foi do adesivo universal na forma convencional nos dois tempos testados.


Assuntos
Cimentos Dentários , Materiais Dentários , Métodos , Resistência ao Cisalhamento , Dentina
5.
Bauru; s.n; 2016. 53 p. tab, graf.
Tese em Inglês | BBO - Odontologia | ID: biblio-881476

RESUMO

Propósito: Avaliar a influência de diferentes concentrações do 10-MDP no grau de conversão (%GC) de adesivos experimentais (AE) em diferentes protocolos de manipulação (PM). Material e Métodos: Os AE contêm um sistema iniciador triplo (CQ/DABE/sal diodônio) e diferentes concentrações de 10-MDP A1 = 0%, A2 = 3%, A3 = 6%, A4 = 9%, A5 = 12% ou A6 = 15% em peso foram adicionadas. Um adesivo comercialmente disponível foi utilizado para comparação (Ambar, FGM). Os adesivos foram divididos em 4 PM: I) Controle (sem manipulação), II) 5 s de evaporação, III) 20 s de evaporação e IV) adição de água. O GC foi avliado com o FTIR-ATR. Os dados foram analisados com Anova a dois critérios e Tukey (α = 0,05). Resultados: Diferenças significativas foram encontradas entre os adesivos (p < 0.0001) e PM (p = 0.000001). Também foi encontrado um efeito de interação (p < 0.0001). Para os adesivos, foi observado que o A5 obteve o maior resultado (89.70% ± 4.21) e o com menor valor foi o AE sem MDP (76.35% ± 8.45). O Ambar obteve valores intermediários (83.68% ± 9.46). Para o PM, o maior valor foi para: Controle (88.50% ± 2.72) > 20-s-evaporação (85.13% ± 6.95) ≈ 5-s-evaporação (85.18% ± 6.08) ≈ adição de água (85.80% ± 10.33). Conclusão: Os resultados obtidos sugerem que o 10- MDP pode aumentar a %GC dos AE com o sistema iniciador triplo.(AU)


Purpose: To evaluate the influence of different concentrations of 10-MDP in degree of conversion (%DC) of experimental adhesives (EA) applied with different manipulation protocols (MP). Materials and Methods: EA containing a three-component-photoinitiator system (CQ/DABE/iodonium salt) were prepared and different concentrations of 10-MDP were added A1 = 0%, A2 = 3%, A3 = 6%, A4 = 9%, A5 = 12%, or A6 = 15% by weight. A commercially available adhesive was used as comparison (Ambar, FGM). The adhesives were divided into 4 MP: I) Control (without any manipulation), II) 5 s of evaporation, III) 20 s of evaporation and IV) addition of water to the adhesive. DC was evaluated by FTIR-ATR. The data were analyzed with two-way Anova and Tukey´s HSD (α = 0.05). Results: Significant differences were found between the adhesives (p < 0.0001) and MP (p = 0.000001). An interaction effect (p < 0.0001) was also observed. For adhesives, it was observed that the A5 showed the highest value (89.70% ± 4.21) and the lowest values to EA without MDP (76.35% ± 8.45). Ambar showed intermediate values (83.68% ± 9.46). For MP, the highest DC was observed to Control (88.50% ± 2.72) > 20-s-evaporation (85.13% ± 6.95) ≈ 5-s-evaporation (85.18% ± 6.08) ≈ addition of water (85.80% ± 10.33). Conclusion: The results suggest that 10- MDP can enhance the %DC of the threecomponent- photoinitiator system EAs evaluated.(AU)


Assuntos
Cimentos Dentários/química , Metacrilatos/química , Teste de Materiais , Transição de Fase , Fotoiniciadores Dentários/química , Polimerização , Valores de Referência , Reprodutibilidade dos Testes , Espectroscopia de Infravermelho com Transformada de Fourier , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA