Int J Cardiol ; 400: 131768, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38211668

RESUMO

BACKGROUND: Transcatheter edge-to-edge repair (TEER) has become an established treatment for primary and secondary mitral regurgitation (PMR and SMR). The objective of this study was to compare the accuracy of different risk scores for predicting 1-year mortality and the composite endpoint of 1-year mortality and/or heart failure (HF) hospitalization after TEER. METHODS: We analyzed data from 206 patients treated for MR at a tertiary European center between 2011 and 2023 and compared the accuracy of different mitral and surgical risk scores: EuroSCORE II, GRASP, MITRALITY, MitraScore, TAPSE/PASP-MitraScore, and STS for predicting 1-year mortality and the composite of 1-year mortality and/or HF hospitalization in PMR and SMR. A subanalysis of SMR-only patients with the addition of COAPT Risk Score and baseline N-Terminal pro-Brain Natriuretic Peptide (NT-proBNP) list was also performed. RESULTS: MITRALITY had the best discriminative ability for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with an area under the curve (AUC) of 0.74 and 0.74, respectively, in a composed group of PMR and SMR. In a SMR-only population, MITRALITY also presented the best AUC for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with values of 0.72 and 0.72, respectively. CONCLUSION: MITRALITY was the best mitral TEER risk model for both 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization in a population of PMR and SMR patients, as well as in SMR patients only. Surgical risk scores, MitraScore, TAPSE/PASP-MitraScore and NT-proBNP alone showed poor predictive values.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Hospitalização , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Fatores de Risco , Resultado do Tratamento
2.
Front Cardiovasc Med ; 10: 1228305, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028447

RESUMO

Background: Periprocedural myocardial injury (PPMI) frequently occurs after transcatheter aortic valve implantation (TAVI), although its impact on long-term mortality is uncertain. Methods: We performed a pooled analysis of Kaplan-Meier-derived individual patient data to compare survival in patients with and without PPMI after TAVI. Flexible parametric models with B-splines and landmark analyses were used to determine PPMI prognostic value. Subgroup analyses for VARC-2, troponin, and creatine kinase-MB (CK-MB)-defined PPMI were also performed. Results: Eighteen observational studies comprising 10,094 subjects were included. PPMI was associated with lower overall survival (OS) after two years (HR = 1.46, 95% CI 1.30-1.65, p < 0.01). This was also observed when restricting the analysis to overall VARC-2-defined PPMI (HR = 1.23, 95% CI 1.07-1.40, p < 0.01). For VARC-2 PPMI criteria and VARC-2 troponin-only, higher mortality was restricted to the first 2 months after TAVI (HR = 1.64, 95% CI 1.31-2.07, p < 0.01; and HR = 1.32, 95% CI 1.05-1.67, p = 0.02, respectively), while for VARC-2 defined CK-MB-only the increase in mortality was confined to the first 30 days (HR = 7.44, 95% CI 4.76-11.66, p < 0.01). Conclusion: PPMI following TAVI was associated with lower overall survival compared with patients without PPMI. PPMI prognostic impact is restricted to the initial months after the procedure. The analyses were consistent for VARC-2 criteria and for both biomarkers, yet CK-MB was a stronger prognostic marker of mortality than troponin.

3.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
4.
N Engl J Med ; 385(23): 2150-2160, 2021 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-34449183

RESUMO

BACKGROUND: The role of direct oral anticoagulants as compared with vitamin K antagonists for atrial fibrillation after successful transcatheter aortic-valve replacement (TAVR) has not been well studied. METHODS: We conducted a multicenter, prospective, randomized, open-label, adjudicator-masked trial comparing edoxaban with vitamin K antagonists in patients with prevalent or incident atrial fibrillation as the indication for oral anticoagulation after successful TAVR. The primary efficacy outcome was a composite of adverse events consisting of death from any cause, myocardial infarction, ischemic stroke, systemic thromboembolism, valve thrombosis, or major bleeding. The primary safety outcome was major bleeding. On the basis of a hierarchical testing plan, the primary efficacy and safety outcomes were tested sequentially for noninferiority, with noninferiority of edoxaban established if the upper boundary of the 95% confidence interval for the hazard ratio did not exceed 1.38. Superiority testing of edoxaban for efficacy would follow if noninferiority and superiority were established for major bleeding. RESULTS: A total of 1426 patients were enrolled (713 in each group). The mean age of the patients was 82.1 years, and 47.5% of the patients were women. Almost all the patients had atrial fibrillation before TAVR. The rate of the composite primary efficacy outcome was 17.3 per 100 person-years in the edoxaban group and 16.5 per 100 person-years in the vitamin K antagonist group (hazard ratio, 1.05; 95% confidence interval [CI], 0.85 to 1.31; P = 0.01 for noninferiority). Rates of major bleeding were 9.7 per 100 person-years and 7.0 per 100 person-years, respectively (hazard ratio, 1.40; 95% CI, 1.03 to 1.91; P = 0.93 for noninferiority); the difference between groups was mainly due to more gastrointestinal bleeding with edoxaban. Rates of death from any cause or stroke were 10.0 per 100 person-years in the edoxaban group and 11.7 per 100 person-years in the vitamin K antagonist group (hazard ratio, 0.85; 95% CI, 0.66 to 1.11). CONCLUSIONS: In patients with mainly prevalent atrial fibrillation who underwent successful TAVR, edoxaban was noninferior to vitamin K antagonists as determined by a hazard ratio margin of 38% for a composite primary outcome of adverse clinical events. The incidence of major bleeding was higher with edoxaban than with vitamin K antagonists. (Funded by Daiichi Sankyo; ENVISAGE-TAVI AF ClinicalTrials.gov number, NCT02943785.).


Assuntos
4-Hidroxicumarinas/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Inibidores do Fator Xa/uso terapêutico , Piridinas/uso terapêutico , Tiazóis/uso terapêutico , Substituição da Valva Aórtica Transcateter , Vitamina K/antagonistas & inibidores , 4-Hidroxicumarinas/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Inibidores do Fator Xa/efeitos adversos , Feminino , Hemorragia Gastrointestinal/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Mortalidade , Fenindiona/análogos & derivados , Fenindiona/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Piridinas/efeitos adversos , Tiazóis/efeitos adversos , Tromboembolia/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos
5.
JACC Cardiovasc Interv ; 13(11): 1303-1311, 2020 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-32499020

RESUMO

OBJECTIVES: The aim of this study was to assess acute regurgitation following transcatheter aortic valve replacement, comparing different implanted transcatheter heart valves. BACKGROUND: Regurgitation following transcatheter aortic valve replacement influences all-cause mortality. Thus far, no quantitative comparison of regurgitation among multiple commercially available transcatheter heart valves has been performed. METHODS: Aortograms from a multicenter cohort of consecutive 3,976 transcatheter aortic valve replacements were evaluated in this pooled analysis. A total of 2,258 (58.3%) were considered analyzable by an independent academic core laboratory using video densitometry. Results of quantitative regurgitation are shown as percentages. The valves evaluated were the ACURATE (n = 115), Centera (n = 11), CoreValve (n = 532), Direct Flow Medical (n = 21), Evolut PRO (n = 95), Evolut R (n = 295), Inovare (n = 4), Lotus (n = 546), Lotus Edge (n = 3), SAPIEN XT (n = 239), and SAPIEN 3 (n = 397). For the main analysis, only valves with more than 50 procedures (7 types) were used. RESULTS: The Lotus valve had the lowest mean regurgitation (3.5 ± 4.4%), followed by Evolut PRO (7.4 ± 6.5%), SAPIEN 3 (7.6 ± 7.1%), Evolut R (7.9 ± 7.4%), SAPIEN XT (8.8 ± 7.5%), ACURATE (9.6 ± 9.2%) and CoreValve (13.7 ± 10.7%) (analysis of variance p < 0.001). The only valves that statistically differed from all their counterparts were Lotus (as the lowest regurgitation) and CoreValve (the highest). The proportion of patients presenting with moderate or severe regurgitation followed the same ranking order: Lotus (2.2%), Evolut PRO (5.3%), SAPIEN 3 (8.3%), Evolut R (8.8%), SAPIEN XT (10.9%), ACURATE (11.3%), and CoreValve (30.1%) (chi-square p < 0.001). CONCLUSIONS: In this pooled analysis stemming from daily clinical practice, the Lotus valve was shown to have the best immediate sealing. This analysis reflects the objective evaluation of regurgitation by an academic core laboratory (nonsponsored) in a real-world cohort of patients using a quantitative technique.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
6.
Am. j. cardiol ; Am. j. cardiol;125(9): 1369-1377, May., 2020. graf.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1099637

RESUMO

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on preBAV was available for 1,262 patients (99.9%). Primary endpoints were pre-discharge moderate-tosevere paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation (PPI), and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n=1,051) or without predilatation (n=211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs. 3.4%, p=0.214; 30-day PPI 9.0% vs. 8.0%, p=0.660; 30-day death or stroke 4.9% vs. 4.4%, p=0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification. (AU)


Assuntos
Substituição da Valva Aórtica Transcateter , Valva Aórtica
7.
JACC cardiovasc. interv ; 12(5): 433-443, Mar. 2019. tabela, gráfico
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024526

RESUMO

Abstract OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: (AU)


Assuntos
Humanos , Substituição da Valva Aórtica Transcateter
8.
EuroIntervention ; 13(4): 432-439, 2017.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062707

RESUMO

AIMS: We aimed to assess the safety and performance of the DREAMS 2G scaffold up to 24 months post implant. METHODS AND RESULTS: The present study population comprises a total of 184 patients with 189 lesions who were enrolled in the prospective, multicentre BIOSOLVE-II and BIOSOLVE-III trials. Clinical follow-up was scheduled at one, six, 12, 24 and 36 months. The present report includes pooled follow-up data at six months and BIOSOLVE-II data at 24 months. Patients were 65.5±10.8 years old, and lesions were 12.5±5.1 mm long with reference diameters of 2.7±0.4 mm. Procedural success was obtained in 97.8%. At six months, the composite clinical endpoint target lesion failure was 3.3% (95% CI: 1.2-7.1), based on two cardiac deaths (1.1%, one unknown and one not device-related), one target vessel myocardial infarction (0.6%), and three clinically driven target lesion revascularisations (1.7%). For BIOSOLVE-II at 24 months, the target lesion failure rate was 5.9% (95% CI: 2.4-11.8), based on two cardiac deaths (1.7%), one target vessel myocardial infarction (0.9%) and four target lesion revascularisations (3.4%). There was no definite or probable scaffold thrombosis...


Assuntos
Coração , Doenças Cardiovasculares , Estudos de Casos e Controles , Stents Farmacológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA