RESUMO
An improved LC-MS/MS method for the quantitation of indapamide in human whole blood was developed and validated. Indapamide-d3 was used as internal standard (IS) and liquid-liquid extraction was employed for sample preparation. LC separation was performed on Synergi Polar RP-column (50 × 4.6 mm i.d.; 4 µm) and mobile phase composed of methanol and 5 mm aqueous ammonium acetate containing 1 mm formic acid (60:40), at flow rate of 1 mL/min. The run time was 3.0 min and the injection volume was 20 µL. Mass spectrometric detection was performed using electrospray ion source in negative ionization mode, using the transitions m/z 364.0 â m/z 188.9 and m/z 367.0 â m/z 188.9 for indapamide and IS, respectively. Calibration curve was constructed over the range 0.25-50 ng/mL. The method was precise and accurate, and provided recovery rates >80% for indapamide and IS. The method was applied to determine blood concentrations of indapamide in a bioequivalence study with two sustained release tablet formulations. The 90% confidence interval for the geometric mean ratios for maximum concentration was 95.78% and for the area under the concentration-time curve it was 97.91%. The tested indapamide tablets (Eurofarma Laboratórios S.A.) were bioequivalent to Natrilix®, according to the rate and extent of absorption.
Assuntos
Cromatografia Líquida/métodos , Indapamida/sangue , Indapamida/farmacocinética , Espectrometria de Massas em Tandem/métodos , Adolescente , Adulto , Humanos , Indapamida/química , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray , Equivalência Terapêutica , Adulto JovemRESUMO
A new method was developed for the quantitation of 3-α-hydroxy tibolone, in human plasma, after oral administration of a tablet formulation containing tibolone (2.5 mg). 3-α-Hydroxy tibolone was extracted by a liquid-liquid procedure, using cyproterone acetate as internal standard and chlorobutane as extraction solvent. After extraction, samples were submitted to a derivatization step with p-toluenesulfonyl isocyanate. A mobile phase consisting of acetonitrile and water (72:28 v/v) was used and chromatographic separation was achieved using Agilent XDB C18 column (100 × 4.6 mm i.d.; 5 µm particle size), at 40°C. Mass spectrometric detection was performed using atmospheric pressure chemical ionization in negative mode for 3-α-hydroxy tibolone and in positive mode for cyproterone acetate. The fragmentation transitions were m/z 510.2 â m/z 170.1 and m/z 417.0 â m/z 357.1 for 3-α-hydroxy tibolone and cyproterone acetate, respectively. Calibration curves were constructed over the range 100-30,000 pg/mL and the method was shown to be specific, precise and accurate, with a mean recovery rate of 94.2% for 3-α-hydroxy tibolone. No matrix effect or carry-over was detected in the samples. The validated method was applied in a pharmacokinetic study with a tibolone formulation in healthy female volunteers.