Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Clinics (Sao Paulo) ; 72(10): 637-641, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29160427

RESUMO

Uterine leiomyoma is the most frequently occurring solid pelvic tumor in women during the reproductive period. Magnetic resonance-guided high-intensity focused ultrasound is a promising technique for decreasing menorrhagia and dysmenorrhea in symptomatic women. The aim of this study is to review the role of Magnetic resonance-guided high-intensity focused ultrasound in the treatment of uterine fibroids in symptomatic patients. We performed a review of the MEDLINE and Cochrane databases up to April 2016. The analysis and data collection were performed using the following keywords: Leiomyoma, High-Intensity Focused Ultrasound Ablation, Ultrasonography, Magnetic Resonance Imaging, Menorrhagia. Two reviewers independently performed a quality assessment; when there was a disagreement, a third reviewer was consulted. Nineteen studies of Magnetic resonance-guided high-intensity focused ultrasound-treated fibroid patients were selected. The data indicated that tumor size was reduced and that symptoms were improved after treatment. There were few adverse effects, and they were not severe. Some studies have reported that in some cases, additional sessions of Magnetic resonance-guided high-intensity focused ultrasound or other interventions, such as myomectomy, uterine artery embolization or even hysterectomy, were necessary. This review suggests that Magnetic resonance-guided high-intensity focused ultrasound is a safe and effective technique. However, additional evidence from future studies will be required before the technique can be recommended as an alternative treatment for fibroids.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Leiomioma/cirurgia , Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias Uterinas/cirurgia , Feminino , Humanos , Histerectomia/métodos , Leiomioma/diagnóstico por imagem , Leiomioma/patologia , Qualidade de Vida , Resultado do Tratamento , Carga Tumoral , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/patologia
2.
Clinics ; Clinics;72(10): 637-641, Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-890682

RESUMO

Uterine leiomyoma is the most frequently occurring solid pelvic tumor in women during the reproductive period. Magnetic resonance-guided high-intensity focused ultrasound is a promising technique for decreasing menorrhagia and dysmenorrhea in symptomatic women. The aim of this study is to review the role of Magnetic resonance-guided high-intensity focused ultrasound in the treatment of uterine fibroids in symptomatic patients. We performed a review of the MEDLINE and Cochrane databases up to April 2016. The analysis and data collection were performed using the following keywords: Leiomyoma, High-Intensity Focused Ultrasound Ablation, Ultrasonography, Magnetic Resonance Imaging, Menorrhagia. Two reviewers independently performed a quality assessment; when there was a disagreement, a third reviewer was consulted. Nineteen studies of Magnetic resonance-guided high-intensity focused ultrasound-treated fibroid patients were selected. The data indicated that tumor size was reduced and that symptoms were improved after treatment. There were few adverse effects, and they were not severe. Some studies have reported that in some cases, additional sessions of Magnetic resonance-guided high-intensity focused ultrasound or other interventions, such as myomectomy, uterine artery embolization or even hysterectomy, were necessary. This review suggests that Magnetic resonance-guided high-intensity focused ultrasound is a safe and effective technique. However, additional evidence from future studies will be required before the technique can be recommended as an alternative treatment for fibroids.


Assuntos
Humanos , Feminino , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Leiomioma/cirurgia , Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias Uterinas/cirurgia , Histerectomia/métodos , Leiomioma/diagnóstico por imagem , Leiomioma/patologia , Qualidade de Vida , Resultado do Tratamento , Carga Tumoral , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/patologia
3.
Clinics ; Clinics;69(3): 185-189, 3/2014. tab
Artigo em Inglês | LILACS | ID: lil-703605

RESUMO

OBJECTIVE: Minimally invasive methods are used as alternatives to treat leiomyomas and include uterine artery embolization, which has emerged as a safe, effective method. This study aims to evaluate the magnetic resonance imaging predictors for a reduction in leiomyoma volume in patients undergoing uterine artery embolization. METHODS: This prospective longitudinal study was performed at a university hospital. We followed 50 symptomatic premenopausal women with uterine leiomyomas who underwent uterine artery embolization. We examined 179 leiomyomas among these patients. Magnetic resonance imaging was performed one month before and six months after uterine artery embolization. Two radiologists who specialized in abdominal imaging independently interpreted the images. Main Outcome Measures: The magnetic resonance imaging parameters were the uterus and leiomyomas volumes, their localizations, contrast perfusion pattern and node-to-muscle ratio. RESULTS: Six months after treatment, the average uterine volume reduction was 38.91%, and the leiomyomas were reduced by 55.23%. When the leiomyomas were submucosal and/or had a higher node-to-muscle ratio in the T2 images, the volume reduction was even greater (greater than 50%). Other parameters showed no association. CONCLUSIONS: We conclude that symptomatic uterine leiomyomas in patients undergoing uterine artery embolization exhibit volume reductions greater than 50% by magnetic resonance imaging when the leiomyomas are submucosal and/or had a high node-to-muscle ratio in the T2 images. .


Assuntos
Adulto , Feminino , Humanos , Leiomioma/terapia , Imageamento por Ressonância Magnética/métodos , Neoplasias Pélvicas/terapia , Embolização da Artéria Uterina/métodos , Neoplasias Uterinas/terapia , Leiomioma/patologia , Análise Multivariada , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Neoplasias Pélvicas/patologia , Fatores de Tempo , Resultado do Tratamento , Carga Tumoral , Neoplasias Uterinas/patologia , Útero/irrigação sanguínea , Útero/patologia
4.
Rev Bras Ginecol Obstet ; 32(2): 77-81, 2010 Feb.
Artigo em Português | MEDLINE | ID: mdl-20305945

RESUMO

PURPOSE: to determine the dose of ionizing radiation absorbed by the ovaries and the skin of patients undergoing uterine fibroid embolization (UFE), and to suggest a radiologic protocol directed at reducing the risks involved in this procedure. METHODS: seventy-three consecutive women (mean age: 27 years) participating in an institutional research protocol, having symptomatic uterine fibroids with indication for minimally invasive treatment, underwent UFE. We estimated the radiation absorbed by the ovaries by means of vaginal dosimeters and the radiation dose absorbed by the skin by means of indirect calculations of radiation absorption. The first 49 patients belonged to the Pre-modification Group, and the last 24, to the Post-modification Group. The second group received a modified protocol of X-ray imaging, with a reduction by half of the frames number per second during arteriography, in an attempt to match the values obtained to those of the literature, and avoiding as much as possible unnecessary exposure to the X-ray beam. RESULTS: there were no technical complications in any of the procedures performed. There were no differences in the mean fluoroscopy time or in the mean number of arteriographies between the two groups. We obtained a 57% reduction in the estimated absorbed ovarian dose between groups (29.0 versus 12.3 cGy) and a 30% reduction in the estimated dose absorbed by the skin (403.6 versus 283.8 cGy). CONCLUSIONS: a significant reduction in the absorption of radiation in patients undergoing UFE can be achieved by changing the number of frames per second in angiographic series, and by the routine use of radiological protection standards.


Assuntos
Embolização Terapêutica , Leiomioma/terapia , Doses de Radiação , Neoplasias Uterinas/terapia , Adulto , Feminino , Humanos , Lesões por Radiação/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA