J Prosthet Dent ; 88(5): 516-21, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12474002

RESUMO

STATEMENT OF PROBLEM: Two problems found in prostheses with soft liners are bond failure to the acrylic resin base and loss of elasticity due to material aging. PURPOSE: This in vitro study evaluated the effect of thermocycling on the bond strength and elasticity of 4 long-term soft denture liners to acrylic resin bases. MATERIAL AND METHODS: Four soft lining materials (Molloplast-B, Flexor, Permasoft, and Pro Tech) and 2 acrylic resins (Classico and Lucitone 199) were processed for testing according to manufacturers' instructions. Twenty rectangular specimens (10 x 10-mm(2) cross-sectional area) and twenty cylinder specimens (12.7-mm diameter x 19.0-mm height) for each liner/resin combination were used for the tensile and deformation tests, respectively. Specimen shape and liner thickness were standardized. Samples were divided into a test group that was thermocycled 3000 times and a control group that was stored for 24 hours in water at 37 degrees C. Mean bond strength, expressed in megapascals (MPa), was determined in the tensile test with the use of a universal testing machine at a crosshead speed of 5 mm/min. Elasticity, expressed as percent of permanent deformation, was calculated with an instrument for measuring permanent deformation described in ADA/ANSI specification 18. Data from both tests were examined with 1-way analysis of variance and a Tukey test, with calculation of a Scheffé interval at a 95% confidence level. RESULTS: In the tensile test under control conditions, Molloplast-B (1.51 +/- 0.28 MPa [mean +/- SD]) and Pro Tech (1.44 +/- 0.27 MPa) liners had higher bond strength values than the others (P <.05). With regard to the permanent deformation test, the lowest values were observed for Molloplast-B (0.48% +/- 0.19%) and Flexor (0.44% +/- 0.14%) (P <.05). Under thermocycling conditions, the highest bond strength occurred with Molloplast-B (1.37 +/- 0.24 MPa) (P <.05). With regard to the deformation test, Flexor (0.46% +/- 0.13%) and Molloplast-B (0.44% +/- 0.17%) liners had lower deformation values than the others (P <.05). CONCLUSION: The results of this in vitro study indicated that bond strength and permanent deformity values of the 4 soft denture liners tested varied according to their chemical composition. These tests are not completely valid for application to dental restorations because the forces they encounter are more closely related to shear and tear. However, the above protocol serves as a good method of investigation to evaluate differences between thermocycled and control groups.


Assuntos
Materiais Biocompatíveis/química , Colagem Dentária , Reembasadores de Dentadura , Resinas Acrílicas/química , Adesividade , Análise de Variância , Intervalos de Confiança , Bases de Dentadura , Dimetilpolisiloxanos/química , Elasticidade , Humanos , Teste de Materiais , Metacrilatos/química , Ácidos Polimetacrílicos/química , Elastômeros de Silicone/química , Estatística como Assunto , Estresse Mecânico , Propriedades de Superfície , Temperatura , Resistência à Tração , Termodinâmica , Fatores de Tempo , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA