Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Food Chem ; 399: 133902, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36027808

RESUMO

The aim of this manuscript was to validate and apply an analytical methodology for the simultaneous determination of 34 mycotoxins in cocoa. The extraction method used in the tests was a liquid-liquid partition by NaCl addition with a freezing step followed by quantification using LC-MS/MS. The results were discussed based on national and international directives for food contaminants. The recoveries and precision were adequate, except for the mycotoxins ionized with the ammonium adduct (NH4+), E-cristinine and ß-ZOL. This result directly influenced the measurement uncertainty of these mycotoxins, because the precision and the correction factor of the recovery were the factors with the greatest impact on the uncertainty of the method. The evaluation of the matrix effect showed considerable signal suppression for 53 % of the evaluated mycotoxins. Nevertheless, the mycotoxins exhibited relatively low quantification limits, with values between 1 and 75 µg kg-1. The validated methodology was applied to 15 cocoa samples collected in warehouses in Brazil. Positive results were found for all the evaluated samples, in which nine toxins were detected out of the 34 investigated.


Assuntos
Cacau , Micotoxinas , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Micotoxinas/análise , Espectrometria de Massas em Tandem/métodos , Incerteza
2.
Anal Bioanal Chem ; 412(8): 1757-1767, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32016569

RESUMO

This work proposes an extraction method based on the "dilute and shoot" approach and QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) for the simultaneous determination of 42 mycotoxins (34 quantified and 8 qualitatively studied) in dried cocoa bean samples. The purpose of the developed methodology was the reduction of co-extractives from the matrix and an efficient extraction without a cleanup step, and subsequent analysis by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). In order to obtain the best extraction conditions, gravimetric tests were performed and parameters that influenced the extraction efficiency were evaluated, such as the proportion of extraction phases, amount of salt, acidification, and extraction time. The performance of the developed method was evaluated to ensure its reliability. Considering the recovery range of 70-120% as an accuracy parameter, four of the mycotoxins under study (acetyl T-2, tenuazonic acid, wortmannin, and zearalenone) showed undesirable values at one of the levels evaluated. The repeatability of the method was assessed for 34 mycotoxins by the relative standard deviation (RSD%) of the responses, and all presented satisfactory values. The quantification limits ranged from 1.0 to 33.0 µg kg-1. Modification of the extraction methods made it possible to simultaneously analyze multiple mycotoxins, eliminating the need for the cleanup step, which led to analyte losses. The proposed methodology has a low cost, which makes it advantageous in routine analysis. It also has the potential for scope extension to cocoa-based foods, which are naturally exposed to a greater variety of mycotoxins. Graphical abstract.


Assuntos
Cacau/química , Cromatografia Líquida/métodos , Micotoxinas/análise , Espectrometria de Massas em Tandem/métodos , Limite de Detecção , Reprodutibilidade dos Testes
3.
Food Chem ; 211: 130-9, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27283616

RESUMO

Bee products can be produced in an environment contaminated by pesticides that can be transported by honey bees to the hive and incorporated into the honey. Therefore, rapid and modern methods to determine pesticide residues in honey samples are essential to guarantee consumers' health. In this study, a simple multiresidue method for the quantification of 116 pesticides in honey is proposed. It involves the use of a modified QuEChERS procedure followed by UHPLC-MS/MS analysis. The method was validated according to the European Union SANCO/12571/2013 guidelines. Acceptable values were obtained for the following parameters: linearity, limit of detection (0.005mg/kg) and limit of quantification (0.010 and 0.025mg/kg), trueness (for the four tested levels the recovery assays values were between 70 and 120%), intermediate precision (RSD<20.0%) and measurement uncertainty tests (<50.0%). The validated method was applied for determination of 100 honey samples from five states of Brazil.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Contaminação de Alimentos/análise , Mel/análise , Resíduos de Praguicidas/análise , Espectrometria de Massas em Tandem/métodos , Animais , Abelhas , Brasil , União Europeia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Talanta ; 144: 740-4, 2015 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-26452885

RESUMO

Carbadox (CBX) and olaquindox (OLA) were used in poultry and swine feed for growth promotion, to improve feed efficiency and increase the rate of weight gain. However, the use of these agents in feedingstuffs was prohibited because of concerns about their toxicity. Regulatory laboratories are required to have suitably validated analytical methods to ensure compliance with the ban. A quantitative and confirmatory method for determining the presence of CBX and OLA in poultry and swine feed by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed, optimized, and validated. The analytes extraction was performed with a mixture of water and acetonitrile (1:1v/v) and cleanup with hexane and C18 (dispersive phase). The method was evaluated by the following parameters: specificity, linearity, matrix effect, decision limits (CCα), detection capability (CCß), accuracy, precision, limits of detection (LoD), limits of quantification (LoQ) and measurement uncertainty. The validated method presented a broad linear study range and no significant matrix effect. The limit of detection (LoD) was defined at 9 µg kg(-1) for CBX and 80 µg kg(-1) for OLA, and the limit of quantification (LoQ) was defined at 12 µg kg(-1) and 110 µg kg(-1) for CBX and OLA, respectively. The accuracy of the method was adequate for CBX and OLA. The recovery values found in the repeatability conditions were 99.41% for CBX and 104.62% for OLA. Under intralaboratory reproducibility conditions, the values were 98.63% for CBX and 95.07% for OLA. It was concluded that the performance parameters demonstrated total method adequacy for the detection and quantification of CBX and OLA in poultry and swine feedingstuffs.


Assuntos
Ração Animal/análise , Carbadox/análise , Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Aves Domésticas , Quinoxalinas/análise , Suínos , Animais , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas em Tandem
5.
Artigo em Inglês | MEDLINE | ID: mdl-22059454

RESUMO

A method using QuEChERS extraction and LC-MS/MS in electrospray positive ionisation mode was developed and validated for the analysis of 90 pesticides in a high water content matrix (tomato) in a single chromatographic run. To assess the intra-laboratory reproducibility of the method, validation was conducted on four different days by two different analysts. The validation data was treated using a spreadsheet developed in-house, which sets the most appropriate model for linear fit by determining whether the residuals of the calibration curves are homocedastic or heterocedastic. A statistical test for the significance of regression was also carried out. Calibration was always matrix-matched and the curves were obtained over the range 0.0075-0.10 or 0.020-0.125 mg kg(-1). Identification of analytes was based on retention times and MRM ratios. Recoveries were assessed at four different levels for each analyte and were between 73 and 106%, with relative standard deviations under reproducibility conditions of <20%. The measurement uncertainties of the method for each pesticide analysed were below 50%. Previous validation of the same method, applied to papaya samples and satisfactory results obtained in various proficiency tests with different high water content matrices, demonstrated the applicability of the method to these classes of commodities, without clean-up. The validated method will be applied routinely in the pesticide residues monitoring programme that constitutes the National Residue and Contaminant Control Plan of Brazil.


Assuntos
Cromatografia Líquida/métodos , Contaminação de Alimentos/análise , Resíduos de Praguicidas/análise , Espectrometria de Massas em Tandem/métodos , Brasil , Análise de Alimentos/métodos , Análise de Alimentos/normas , Contaminação de Alimentos/prevenção & controle , Contaminação de Alimentos/estatística & dados numéricos , Frutas/química , Limite de Detecção , Solanum lycopersicum/química , Resíduos de Praguicidas/normas , Padrões de Referência , Verduras/química , Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA