Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 129(3): 456-463, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34238537

RESUMO

STATEMENT OF PROBLEM: Various strategies have been proposed to reduce the cement space of foundation restorations for endodontically treated teeth. However, they may add more operative steps, or the dentist must keep different sizes of drills and posts in stock. A 2-piece universal adjustable post system has been developed to overcome this problem, but whether the system has acceptable fatigue survival performance is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the fatigue survival and stress distribution of endodontically treated teeth without a ferrule and restored with different glass fiber post strategies versus a recently introduced universal 2-piece fiber post system. MATERIAL AND METHODS: Bovine incisor roots were randomly assigned to 3 groups as per the post used (n=13): adapted glass fiber post with post space preparation of the same size, composite resin-custom glass fiber post (CTM), and universal 2-piece glass fiber-reinforced composite resin post (UNI). The posts were adhesively luted, the composite resin core was added, and a composite resin crown was produced with computer-aided design and computer-aided manufacturing (CAD-CAM), and then adhesively luted to each core. A fatigue test was performed with the stepwise stress method (10 000 cycles/step; 20 Hz; load=100 N to 750 N; step=50 N) until fracture, and the failure mode analyzed. The stress distribution was evaluated by finite element analysis with the maximum principal stress criteria by following the parameters of the in vitro test. The solids were considered homogeneous, linear, and isotropic, except for the glass fiber post (orthotropic), and a load of 450 N at 30 degrees was applied. The fatigue failure load and the number of cycles for failure were analyzed with Kaplan-Meier and Mantel-Cox (log rank test) (α=.05). The finite element analysis results were analyzed with colorimetric graphs. RESULTS: The highest fatigue failure load and the number of cycles for failure were found in the UNI system, whereas the lowest results were found in the CTM group. All groups exhibited repairable failures. The finite element analysis showed the lowest stress in root dentin in the UNI system. The CTM system had the largest stress regions at the dentin and dentin-core interface. CONCLUSIONS: The use of a 2-piece universal glass fiber post system resulted in more fatigue behavior compared with composite resin-custom glass fiber posts.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Animais , Bovinos , Cerâmica , Resinas Compostas , Análise do Estresse Dentário , Vidro , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Dente não Vital/terapia
2.
J Clin Exp Dent ; 12(1): e38-e45, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31976042

RESUMO

BACKGROUND: This study evaluated the mechanical response of a removable partial denture (RPD) in Kennedy Class II according to being associated or not with implants. MATERIAL AND METHODS: Four RPDs were manufactured for a Kennedy Class II: CRPD - Conventional RPD, RPD+1M, RPD+2M and RPD+12M, respectively, signifying implant assisted RPDs with the implant installed in the first molar, second molar, and in the first and second molars. The finite element method was used to determine the most damaged support tooth under compressive load (300N, 10s) and strain gauge analysis was used to evaluate the microstrain. All groups were submitted to a retentive force analysis (0.5 mm/mm, 100kgf). Microstrain and retentive force data were submitted to One-way ANOVA and the Tukey test, all with α=5%. RESULTS: High microstrain was observed in the second premolar adjacent to the edentulous space under compression load (p< 0.01). RPD+12M presented lower microstrain, however being similar to RPD+2M. RPD+1M presented a higher mean value of retentive force, but similar to RPD+12M. FEM showed RPD assisted by implants concentrates less stress in the periodontal ligament. The association of two implants was sufficient to decrease the stress generated in the implants. The most stressed region for the o-ring abutment was the threads, and the group with two implants showed the lowest stress concentration. CONCLUSIONS: In cases of Kennedy Class II, the association of RPD with implants in the molar region is a favorable option for patient rehabilitation, reducing the movement of the direct retainer adjacent to the edentulous space, increasing the removal force and decreasing the stress magnitude in the periodontal ligament. Key words:Removable partial denture, Finite element analysis, Prosthetic dentistry, Implant-assisted RPD, Distal extension RPD considerations.

3.
Eur J Esthet Dent ; 5(3): 288-98, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20820458

RESUMO

The objective of the study was to evaluate the effect of immediate polishing, after 24 h and after 1 week, on the surface roughness of two micro-hybrid resins (Esthet-X; Opallis) and one nanoparticle resin (Filtek Z350), as well as verifying maintenance of the polish after 1 year, simulated by means of thermal cycling. Forty-three specimens of each material were made and divided into a control group and three experimental groups. The control group specimens received no surface treatment. Group 1 received finishing with an extra-fine diamond drill and posterior polishing with the systems Enhance and PoGo, immediately after polymerization. Group 2 received the same procedures; however, these were carried out after 24 h of storage. Group 3 received the surface treatment after 7 days of storage. After that, the surface roughness was evaluated by a profilometer. After the initial reading, the specimens were submitted to thermal cycling for 10,000 cycles. After thermal cycling, a new roughness reading was taken. The results showed a higher roughness value for the resin Esthet-X, and the resins Opallis and Z350 presented the same roughness values. As regards the time when polishing was performed, specimens polished immediately after polymerization presented higher roughness values in comparison with the other two periods. After thermal cycling, the statistical analysis showed that the Opallis resin polish had been maintained, whereas for the other two resins, there was a significant reduction in surface smoothness. The surface roughness was influenced by the material and also by the period of polishing; the surface roughness of all tested materials were at a clinically acceptable level.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Polimento Dentário/métodos , Nanopartículas/química , Silicatos de Alumínio/química , Compostos de Bário/química , Bis-Fenol A-Glicidil Metacrilato/química , Polimento Dentário/instrumentação , Diamante/química , Vidro/química , Humanos , Teste de Materiais , Polietilenoglicóis/química , Polímeros/química , Ácidos Polimetacrílicos/química , Propriedades de Superfície , Temperatura , Fatores de Tempo , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA