1.
Chemosphere ; 341: 139948, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37648170

RESUMO

Environmental impacts caused by mining activities (mainly tailings and effluents) are presenting serious challenges for humanity worldwide. In Brazil, clay extraction activities in the Ceramic District of Santa Gertrudes (CDSG) have led to the formation of abandoned drainage wells causing environmental and human health concerns. In the 90's, it was discovered that in one of the production areas, known as the region of the lakes of Santa Gertrudes, several ceramic industries had contaminated lakes created by abandoned clay pits with industrial effluents containing toxic metals. In the present study, analysis of total and dissolved concentrations of Al, Cd, Co, Cu, Mn, Ni, Pb and Zn in the waters of these lakes were combined with the diffusive gradients in thin films (DGT) technique to assess the lability and bioavailability of the target elements, representing one of the first studies to investigate the real environmental impact of contamination caused by ceramic production wastes to an aquatic system. Furthermore, based on the total concentrations and main physicochemical characteristics of each lake, a speciation analysis was performed using the MINTEQ software which data was compared with other surface water systems. The results indicated the presence of metals associated with ceramic residues in total, dissolved and labile fractions. It was verified that Zn, Ni and Cu were the only target metals found in labile form and according to speciation were present in the form of "free" ions, and thus may present risk in terms of bioavailability, although the majority of the total concentrations are within the limits established by the national environmental agency.


Assuntos
Metais Pesados , Poluentes Químicos da Água , Humanos , Lagos/química , Argila , Brasil , Metais/análise , Mineração , Monitoramento Ambiental/métodos , Poluentes Químicos da Água/análise , Metais Pesados/análise
2.
Talanta ; 238(Pt 2): 123044, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34801901

RESUMO

The Diffusive Gradients in Thin-films (DGT) technique represents an ideal tool for monitoring water quality of inorganic species in systems with a high flow such as rivers, streams, lakes and seas. However, in low-flow systems (non-turbulent waters), the influence of a diffusive boundary layer (DBL) formed on the surface of the DGT device has been observed, which can lead to erroneous measurements by DGT. Therefore, the use of DGT in wells for groundwater monitoring is still very limited until now. In this sense, the present study evaluates the applicability of the DGT technique in non-turbulent and low-flow water systems. We propose a new way to calculate the DBL with the objective to carry out a robust DGT analysis in environmental monitoring wells. For this purpose, DGT devices with different diffusive gel thicknesses were deployed in an experimental set-up simulating a groundwater monitoring well. A DBL thickness (for each element) was calculated from the slopes of the linear regressions between the DGT accumulated mass of metal and the deployment time (4, 8, 12, 24 and 48 h) for each of the two diffusive gel thicknesses. The mean DBL thickness (averaging the individual DBL thicknesses calculated from the slopes) was 0.06 cm. The concentrations of the analysed elements were corrected with this DBL with the result that the metal concentrations measured by DGT improved and were highly approximated to their actual total values in this non-complexing medium.


Assuntos
Água Subterrânea , Poluentes Químicos da Água , Difusão , Monitoramento Ambiental , Lagos , Rios , Poluentes Químicos da Água/análise
3.
Talanta ; 179: 563-568, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29310275

RESUMO

A new method to determine iodine in drug samples by high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS) has been developed. The method measures the molecular absorption of a diatomic molecule, CaI or SrI (less toxic molecule-forming reagents), at 638.904 or 677.692nm, respectively, and uses a mixture containing 5µg of Pd and 0.5µg of Mg as chemical modifier. The method employs pyrolysis temperatures of 1000 and 800°C and vaporization temperatures of 2300 and 2400°C for CaI and SrI, respectively. The optimized amounts of Ca and Sr as molecule-forming reagents are 100 and 150µg, respectively. On the basis of interference studies, even small chlorine concentrations reduce CaI and SrI absorbance significantly. The developed method was used to analyze different commercial drug samples, namely thyroid hormone pills with three different iodine amounts (15.88, 31.77, and 47.66µg) and one liquid drug with 1% m v-1 active iodine in their compositions. The results agreed with the values informed by the manufacturers (95% confidence level) regardless of whether CaI or SrI was determined. Therefore, the developed method is useful for iodine determination on the basis of CaI or SrI molecular absorption.