1.
Acta cir. bras. ; 26(5): 329-332, Sept.-Oct. 2011. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-7713

RESUMO

PURPOSE: To investigate the effects of a new electrocautery device to provoke endovascular venous thermal injury. METHODS: An experimental endovascular electrocautery was placed inside eight ex-vivo bovine saphenous veins models. Each one was divided in eight segments and progressive intensities of electric energy liberated. The macroscopic and microscopic effects were analyzed. RESULTS: Forty bovine saphenous veins segments were studied. The higher the electric energy applied the greater the nuclear picnosis and more intense the cytoplasmatic shrinkage and electrocoagulation effects. CONCLUSION: The experimental endovascular electrocautery device demonstrated to be both capable of inducing the destruction of the intimal layers of the studied vein model and provoke endovascular thermal injury.(AU)


OBJETIVO: Investigar os efeitos de um modelo experimental de eletrocautério em provocar lesão venosa térmica endovascular. MÉTODOS: O eletrocautério endovascular foi colocado dentro de oito modelos experimentais de veia safena bovina. Cada uma foi dividida em oito segmentos e intensidades progressivas de energia elétrica liberada. Os efeitos macroscópicos e microscópicos foram analisados. RESULTADOS: Foram estudados quarenta segmentos de veia safena bovina. Quanto maior a energia elétrica aplicada pelo eletrocauterizador endovascular maiores foram as alteraçoes de picnose nuclear e mais intensa a retração citoplasmática observada. CONCLUSÃO: O eletrocautério endovascular experimental demonstrou ser capaz de induzir a destruição da camada íntima e provocar lesão térmica endovascular.(AU)


Assuntos
Bovinos , Eletrocoagulação/métodos , Ferimentos e Lesões , Varizes/genética
2.
Acta cir. bras ; Acta cir. bras;26(5): 329-332, Sept.-Oct. 2011. ilus, tab
Artigo em Inglês | LILACS, Sec. Est. Saúde SP | ID: lil-599632

RESUMO

PURPOSE: To investigate the effects of a new electrocautery device to provoke endovascular venous thermal injury. METHODS: An experimental endovascular electrocautery was placed inside eight ex-vivo bovine saphenous veins models. Each one was divided in eight segments and progressive intensities of electric energy liberated. The macroscopic and microscopic effects were analyzed. RESULTS: Forty bovine saphenous veins segments were studied. The higher the electric energy applied the greater the nuclear picnosis and more intense the cytoplasmatic shrinkage and electrocoagulation effects. CONCLUSION: The experimental endovascular electrocautery device demonstrated to be both capable of inducing the destruction of the intimal layers of the studied vein model and provoke endovascular thermal injury.


OBJETIVO: Investigar os efeitos de um modelo experimental de eletrocautério em provocar lesão venosa térmica endovascular. MÉTODOS: O eletrocautério endovascular foi colocado dentro de oito modelos experimentais de veia safena bovina. Cada uma foi dividida em oito segmentos e intensidades progressivas de energia elétrica liberada. Os efeitos macroscópicos e microscópicos foram analisados. RESULTADOS: Foram estudados quarenta segmentos de veia safena bovina. Quanto maior a energia elétrica aplicada pelo eletrocauterizador endovascular maiores foram as alteraçoes de picnose nuclear e mais intensa a retração citoplasmática observada. CONCLUSÃO: O eletrocautério endovascular experimental demonstrou ser capaz de induzir a destruição da camada íntima e provocar lesão térmica endovascular.


Assuntos
Animais , Bovinos , Queimaduras por Corrente Elétrica/etiologia , Eletrocoagulação/efeitos adversos , Veia Safena/lesões , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Modelos Teóricos , Veia Safena/cirurgia , Condutividade Térmica , Fatores de Tempo
3.
Acta Cir Bras ; 26(5): 329-32, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21952653

RESUMO

PURPOSE: To investigate the effects of a new electrocautery device to provoke endovascular venous thermal injury. METHODS: An experimental endovascular electrocautery was placed inside eight ex-vivo bovine saphenous veins models. Each one was divided in eight segments and progressive intensities of electric energy liberated. The macroscopic and microscopic effects were analyzed. RESULTS: Forty bovine saphenous veins segments were studied. The higher the electric energy applied the greater the nuclear picnosis and more intense the cytoplasmatic shrinkage and electrocoagulation effects. CONCLUSION: The experimental endovascular electrocautery device demonstrated to be both capable of inducing the destruction of the intimal layers of the studied vein model and provoke endovascular thermal injury.


Assuntos
Queimaduras por Corrente Elétrica/etiologia , Eletrocoagulação/efeitos adversos , Veia Safena/lesões , Animais , Bovinos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Modelos Teóricos , Veia Safena/cirurgia , Condutividade Térmica , Fatores de Tempo
4.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;1(1): 20-31, ago. 1986. ilus, tab
Artigo em Português | LILACS | ID: lil-41483

RESUMO

Trata-se de um método de preservaçäo do conjunto coraçäo-pulmäo isolado em condiçöes fisiológicas. Após abertura do tórax, é instituída a autoperfusäo ex-corpore, que se obtém pela canulaçäo do tronco braquicefálico e veia cava superior, conectando-se a um reservatório situado a 1 metro de altura, de tal maneira que, pela contraçäo ventricular esquerda, o sangue é impulsionado ao reservatório, retorna ao coraçäo direito e segue as vías normais, passando pelos pulmöes, onde é oxigenado. A seguir, sem qualquer interrupçäo dos batimentos e da avaliaçäo, o bloco é retirado do tórax e accondicionado no Recipiente para Conservaçäo e Transporte do Conjunto Cardiopulmonar à temperatura normal. Foram empregados 28 cäes, com peso entre 18 e 28 kg, tendo sido feito 8 preservaçöes, para se testar o método, e 10 preservaçöes, para transplante cardiopulmonar em 10 cäes receptores. Foram monitorizados, continuamente, eletrocardiograma, pressäo intraórtica, pressäo ventricular esquerda, DP/DT, índice tempo-tensäo e trabalho cardíaco que mostram valores estáveis e satisfatórios, tanto na fase de preservaçäo, quanto após o transplante. Os gases sangüíneos guardam relaçäo com as diferentes misturas administradas à ventilaçäo. A análise microscópica de fragmentos do músculo cardíaco e tecido pulmonar retirado ao final dos procedimentos näo revelou alteraçöes significativas decorrentes do método


Assuntos
Cães , Animais , Masculino , Coração/transplante , Preservação de Órgãos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA