Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Rev. Bras. Ortop. (Online) ; 54(1): 53-59, Jan.-Feb. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1003603

RESUMO

Abstract Objective Floating knee injuries are complex injuries and are usually caused by highvelocity trauma. These injuries are often associated with life treating injuries, which should take precedent over extremity injuries. The authors reviewed the outcomes of floating knee injuries managed in this institute from 2003 to 2015. Method A retrospective study was conducted of all patients with floating knee injuries from2003 to 2015. Twelve patients were included in the study. Data related to fracture type, associated injuries, treatmentmodalities, and complications were noted. Functional assessment was performed using themodified Karlstromand Olerud criteria after complete bony union. Result The mechanism of injury was motor vehicle accident in all patients. The mean follow up was four years. The mean age of patients was 34.75 year. The mean union time was 6.5 months in femurs and 6.7 month in tibias. The complications were knee stiffness, delayed union, and infection. According to modified Karlstrom criteria, there were three - excellent, five - good, three - fair, and one poor result. Conclusion Floating knee injuries are severe injuries and are usually associated withmultiorgan injuries. Early detection and appropriate management of associated injuries, early fixation of fractures, and postoperative rehabilitation are needed for good outcome. Complications are frequent, in the form of delayed union, knee stiffness, and infection.


Resumo Objetivo As lesões do tipo joelho flutuante (FKIs, na sigla em inglês) são complexas e são geralmente causadas por trauma de alta velocidade. Estas lesões são frequentemente associadas a lesões que causamrisco demorte, que devemter precedente sobre lesões nas extremidades. Os autores revisaram os resultados das lesões do tipo joelho flutuante tratadas nesta instituição entre 2003 e 2015. Método Foi realizado um estudo retrospectivo de todos os pacientes com FKIs de 2003 a 2015. Doze pacientes foram incluídos no estudo. Os dados relacionados ao tipo de fratura, lesões associadas, modalidades de tratamento e complicações foram observados. A avaliação funcional foi realizada utilizando os critérios de Karlstrom modificados após a união óssea completa. Resultados Omecanismo de lesão foi acidente automobilísticoemtodos os pacientes.O acompanhamentomédio foi de 4 anos.Amédia de idade dos pacientes foi de 34,75 anos.O tempo médio de união óssea foi de 6,5 meses nos fêmures e de 6,7 meses nas tíbias. As complicações foram rigidez do joelho, união óssea tardia e infecção. De acordo com os critérios modificados de Karlstrom, três resultados foram considerados excelentes, cinco bons, três razoáveis e um resultado foi considerado ruim. Conclusão Lesões do tipo joelho flutuante são graves e são geralmente associadas a lesões de vários órgãos. A detecção precoce e o tratamento adequado das lesões associadas, a afixação precoce das fraturas e a reabilitação pós-operatória são necessários para um bom resultado. As complicações são frequentes, sob a forma de união óssea tardia, rigidez do joelho e infecção.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Fraturas da Tíbia , Fraturas do Fêmur , Fixação de Fratura , Traumatismos do Joelho
2.
Rev. Bras. Ortop. (Online) ; 53(5): 632-635, Sept.-Oct. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-977890

RESUMO

ABSTRACT The authors report the first case of traumatic late dissociation of the polyethylene insert with patellar tendon rupture after total knee arthroplasty using a high-flex posterior-stabilized Genesis II prosthesis in a 60-year-old Parkinson's disease patient. Insert dislodgement has been described most commonly with mobile-bearing and cruciate-retaining TKAs. Only four cases of insert dissociation in a high-flex fixed-bearing prosthesis have been described to date. This case report paves the way to understanding the potential reasons for insert dissociation and its management strategy.


RESUMO Os autores relatam o primeiro caso de dissociação tardia traumática do inserto de polietileno com ruptura do tendão patelar após artroplastia total do joelho, com o uso de uma prótese Genesis II de alta flexibilidade e estabilização posterior, em paciente com 60 anos com doença de Parkinson. A luxação do inserto plástico tem sido mais comumente descrita em ATJs com suporte de carga móvel e que pouparam o ligamento cruzado. Até o presente, foram descritos apenas quatro casos de dissociação dos insertos de polietileno em próteses de suporte fixo e alta flexibilidade. Este relato de caso abre caminho para a compreensão das potenciais causas de dissociação inserto de polietileno e sua conduta.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Artroplastia , Desenho de Prótese , Artroplastia de Substituição , Articulação do Joelho , Prótese do Joelho
3.
Rev Bras Ortop ; 53(5): 632-635, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30258829

RESUMO

The authors report the first case of traumatic late dissociation of the polyethylene insert with patellar tendon rupture after total knee arthroplasty using a high-flex posterior-stabilized Genesis II prosthesis in a 60-year-old Parkinson's disease patient. Insert dislodgement has been described most commonly with mobile-bearing and cruciate-retaining TKAs. Only four cases of insert dissociation in a high-flex fixed-bearing prosthesis have been described to date. This case report paves the way to understanding the potential reasons for insert dissociation and its management strategy.


Os autores relatam o primeiro caso de dissociação tardia traumática do inserto de polietileno com ruptura do tendão patelar após artroplastia total do joelho, utilizando uma prótese Genesis II de alta flexibilidade e estabilização posterior, em paciente com 60 anos de idade com doença de Parkinson. A luxação do inserto plástico tem sido mais comumente descrita em ATJs com suporte de carga móvel e que pouparam o ligamento cruzado. Até o presente, foram descritos apenas quatro casos de dissociação dos insertos de polietileno em próteses de suporte fixo e alta flexibilidade. Este relato de caso abre caminho para a compreensão das potenciais causas de dissociação inserto de polietileno e sua conduta.

4.
Rev. Bras. Ortop. (Online) ; 53(4): 489-492, July-Aug. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-959164

RESUMO

ABSTRACT Musculoskeletal injuries such as dislocation of the shoulder and hip joints and fractures of the femoral neck are known complications of seizures. Bilateral central subluxation of the hip joint with associated bilateral quadrilateral plate fracture is a rare entity and is prone to delayed diagnosis, even more so in patients who experience post-seizure disorientation. The authors report the case of a 74-year-old male patient with bilateral central subluxation of the hip joint with associated bilateral quadrilateral plate fracture due to seizure activity. Bilateral open reconstruction and fixation of the quadrilateral plate with a 3.5-mm pre-bent reconstruction plate reinforced with 3.5-mm pelvic brim reconstruction plate was performed. In conclusion, this case is an example of rare bilateral quadrilateral plate fracture caused due to seizure activity, a fracture for which a high level of suspicion should be kept in mind while evaluating the patient post-seizure episode.


RESUMO Lesões musculoesqueléticas, tais como luxação das articulações do ombro e quadril e fraturas do colo do fêmur, são complicações conhecidas de convulsões. A subluxação central bilateral da articulação do quadril associada a fratura bilateral da lâmina quadrilátera do acetábulo é uma entidade rara e propensa ao diagnóstico tardio, ainda mais em pacientes que experimentam desorientação pós-convulsão. Os autores relatam o caso de um paciente masculino de 74 anos com subluxação central bilateral da articulação do quadril associada a fratura bilateral da lâmina quadrilátera decorrente de atividade convulsiva. Foi feita reconstrução bilateral aberta e a lâmina quadrilátera foi fixada com uma placa de reconstrução pré-dobrada de 3,5 mm, reforçada com uma placa de reconstrução da borda pélvica de 3,5 mm. Conclui-se que este caso é um raro exemplo de fratura bilateral das lâminas quadriláteras causada pela atividade convulsiva. Os profissionais de saúde devem manter um alto nível de suspeita para esse tipo de fratura ao avaliar pacientes após um episódio convulsivo.


Assuntos
Idoso , Placas Ósseas , Parafusos Ósseos , Fraturas do Úmero
5.
Rev Bras Ortop ; 53(4): 489-492, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30027084

RESUMO

Musculoskeletal injuries such as dislocation of the shoulder and hip joints and fractures of the femoral neck are known complications of seizures. Bilateral central subluxation of the hip joint with associated bilateral quadrilateral plate fracture is a rare entity and is prone to delayed diagnosis, even more so in patients who experience post-seizure disorientation. The authors report the case of a 74-year-old male patient with bilateral central subluxation of the hip joint with associated bilateral quadrilateral plate fracture due to seizure activity. Bilateral open reconstruction and fixation of the quadrilateral plate with a 3.5-mm pre-bent reconstruction plate reinforced with 3.5-mm pelvic brim reconstruction plate was performed. In conclusion, this case is an example of rare bilateral quadrilateral plate fracture caused due to seizure activity, a fracture for which a high level of suspicion should be kept in mind while evaluating the patient post-seizure episode.


Lesões musculoesqueléticas, tais como luxação das articulações do ombro e quadril e fraturas do colo do fêmur, são complicações conhecidas de convulsões. A subluxação central bilateral da articulação do quadril associada a fratura bilateral da alâmina quadrilátera do acetábulo é uma entidade rara e propensa ao diagnóstico tardio, ainda mais em pacientes que experimentam desorientação pós-convulsão. Os autores relatam o caso de um paciente masculino de 74 anos de idade com subluxação central bilateral da articulação do quadril associada a fratura bilateral da lâmina quadrilátera decorrente de atividade convulsiva. Foi feita reconstrução bilateral aberta e a lâmina quadrilátera foi fixada com uma placa de reconstrução pré-dobrada de 3.5 mm, reforçada com uma placa de reconstrução da borda pélvica de 3,5 mm. Conclui-se que este caso é um raro exemplo de fratura bilateral das lâminas quadriláteras causada pela atividade convulsiva. Os profissionais de saúde devem manter um alto nível de suspeita para esse tipo de fratura ao avaliar pacientes após um episódio convulsivo.

6.
Rev Bras Ortop ; 53(3): 323-331, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29892584

RESUMO

OBJECTIVE: The use of open reduction and internal fixation (ORIF) for unstable pelvic injuries is associated with extensive blood loss, iatrogenic neurovascular injury, and infection. Moreover, the placement of sacroiliac (SI) screws is a blinded procedure, guided primarily by palpation and two-dimensional radiological screening, which demands expertise. The complex three-dimensional anatomy of SI joint and its proximity to neurovascular structure require a safe and precise technique. Computed tomography (CT)-guided SI joint stabilization allows an accurate intra-operative assessment of screw placement. This study demonstrated a technique of CT-guided closed reduction and screw fixation of the SI joint in unstable pelvic fractures. METHODS: This was a retrospective non-randomized cohort study conducted at a tertiary care hospital. Six patients with unstable pelvic fractures were operated; the anterior rim was stabilized first by ORIF with plate on the superior and anterior aspects of the pubic symphysis. Subsequently, the posterior stabilization was made percutaneously under CT guidance with a 7-mm cannulated cancellous screw. RESULTS: The mean operative time was 48 min (35-90 min), the mean effective radiation dose was 9.32 (4.97-13.27), and the mean follow-up was 26 months (6-72 months). All patients had satisfactory healing, with near-anatomic reduction and no complications, except in one case where the plate broke at 61 months post surgery, but no intervention was required. The mean VAS score at the final follow-up was 1.8, and all patients returned to their original occupation without any limitations. CONCLUSION: CT-guided SI joint stabilization offers many advantages, including safe and accurate screw placement, reduced operating time, decreased blood loss, early definitive fixation, immediate mobilization, and fewer infections and wound complications.


OBJETIVO: O uso de redução aberta e fixação interna (RAFI) em lesões pélvicas instáveis está associado a hemorragia ampla, lesão neurovascular iatrogênica e infecção. Além disso, os parafusos sacroilíacos (SI) são colocados às cegas − o procedimento é guiado principalmente pela palpação e triagem radiológica bidimensional, o que exige especialização. A complexa anatomia tridimensional da articulação SI e sua proximidade à estrutura neurovascular requerem o uso de uma técnica segura e precisa. A estabilização da articulação SI guiada por tomografia computadorizada (TC) permite uma avaliação intra-operatória precisa do posicionamento do parafuso. Este estudo demonstrou uma técnica, guiada por TC, de redução fechada e fixação da articulação SI com parafusos em fraturas pélvicas instáveis. MÉTODOS: Trata-se de um estudo de coorte retrospectivo, não randomizado, realizado em um hospital terciário. Seis pacientes com fraturas pélvicas instáveis foram operados. A borda anterior foi estabilizada primeiro por RAFI com placa nos aspectos superior e anterior da sínfise púbica. Então, a estabilização posterior foi feita de forma percutânea, guiada por TC, com um parafuso esponjoso canulado de 7 mm. RESULTADOS: O tempo médio de cirurgia foi de 48 min (35-90 min); a dose média efetiva de radiação foi de 9,32 (4,97-13,27) e o seguimento médio foi de 26 meses (6-72 meses). Todos os pacientes apresentaram cura satisfatória, com redução quase anatômica e sem complicações, exceto em um caso em que a placa quebrou 61 meses após a cirurgia, sem a necessidade de intervenção. O escore EVA médio no seguimento final foi de 1,8 e todos os pacientes retornaram às suas ocupações originais sem quaisquer limitações. CONCLUSÃO: A estabilização da articulação SI guiada por TC apresenta muitas vantagens, incluindo um posicionamento seguro e preciso do parafuso, redução do tempo de cirurgia, diminuição da perda de sangue, fixação definitiva precoce, mobilização imediata e redução no número de infecções e complicações da ferida cirúrgica.

7.
Rev. Bras. Ortop. (Online) ; 53(3): 323-331, May-June 2018. graf
Artigo em Inglês | LILACS | ID: biblio-959142

RESUMO

ABSTRACT Objective The use of open reduction and internal fixation (ORIF) for unstable pelvic injuries is associated with extensive blood loss, iatrogenic neurovascular injury, and infection. Moreover, the placement of sacroiliac (SI) screws is a blinded procedure, guided primarily by palpation and two-dimensional radiological screening, which demands expertise. The complex three-dimensional anatomy of SI joint and its proximity to neurovascular structure require a safe and precise technique. Computed tomography (CT)-guided SI joint stabilization allows an accurate intra-operative assessment of screw placement. This study demonstrated a technique of CT-guided closed reduction and screw fixation of the SI joint in unstable pelvic fractures. Methods This was a retrospective non-randomized cohort study conducted at a tertiary care hospital. Six patients with unstable pelvic fractures were operated; the anterior rim was stabilized first by ORIF with plate on the superior and anterior aspects of the pubic symphysis. Subsequently, the posterior stabilization was made percutaneously under CT guidance with a 7-mm cannulated cancellous screw. Results The mean operative time was 48 min (35-90 min), the mean effective radiation dose was 9.32 (4.97-13.27), and the mean follow-up was 26 months (6-72 months). All patients had satisfactory healing, with near-anatomic reduction and no complications, except in one case where the plate broke at 61 months post surgery, but no intervention was required. The mean VAS score at the final follow-up was 1.8, and all patients returned to their original occupation without any limitations. Conclusion CT-guided SI joint stabilization offers many advantages, including safe and accurate screw placement, reduced operating time, decreased blood loss, early definitive fixation, immediate mobilization, and fewer infections and wound complications.


RESUMO Objetivo O uso de redução aberta e fixação interna (RAFI) em lesões pélvicas instáveis está associado a hemorragia ampla, lesão neurovascular iatrogênica e infecção. Além disso, os parafusos sacroilíacos (SI) são colocados às cegas − o procedimento é guiado principalmente pela palpação e triagem radiológica bidimensional, o que exige especialização. A complexa anatomia tridimensional da articulação SI e sua proximidade com a estrutura neurovascular requerem o uso de uma técnica segura e precisa. A estabilização da articulação SI guiada por tomografia computadorizada (TC) permite uma avaliação intraoperatória precisa do posicionamento do parafuso. Este estudo demonstrou uma técnica, guiada por TC, de redução fechada e fixação da articulação SI com parafusos em fraturas pélvicas instáveis. Métodos Estudo de coorte retrospectivo, não randomizado, feito em um hospital terciário. Seis pacientes com fraturas pélvicas instáveis foram operados. A borda anterior foi estabilizada primeiro por RAFI com placa nos aspectos superior e anterior da sínfise púbica. Então, a estabilização posterior foi feita de forma percutânea, guiada por TC, com um parafuso esponjoso canulado de 7 mm. Resultados O tempo médio de cirurgia foi de 48 min (35-90 min); a dose média efetiva de radiação foi de 9,32 (4,97-13,27) e o seguimento médio foi de 26 meses (6-72 meses). Todos os pacientes apresentaram cura satisfatória, com redução quase anatômica e sem complicações, exceto em um caso em que a placa quebrou 61 meses após a cirurgia, sem a necessidade de intervenção. O escore EVA médio no seguimento final foi de 1,8 e todos os pacientes retornaram às suas ocupações originais sem quaisquer limitações. Conclusão A estabilização da articulação SI guiada por TC apresenta muitas vantagens, inclusive um posicionamento seguro e preciso do parafuso, redução do tempo de cirurgia, diminuição da perda de sangue, fixação definitiva precoce, mobilização imediata e redução no número de infecções e complicações da ferida cirúrgica.


Assuntos
Humanos , Masculino , Feminino , Ossos Pélvicos , Parafusos Ósseos , Fixadores Externos , Fraturas Ósseas , Fixação Interna de Fraturas
8.
Rev Bras Ortop ; 52(3): 363-365, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28702399

RESUMO

Simultaneous bilateral neck femur fracture is a rare entity that has been associated with underlying bone disease, various metabolic diseases, high-energy trauma, and seizure disorders. Its occurrence following minimal trauma is very rare. This article presents the case of a 66-year-old female who sustained bilateral intracapsular fracture neck femur following a slip and fall at home. Single-stage bilateral cemented total hip replacement was done using a direct lateral approach with alternate right and left lateral positions. The authors report a satisfactory outcome, with Harris hip score of 98 at one year, which persisted until her last follow-up at 30 months.


A fratura simultânea bilateral do colo do fêmur é uma entidade rara que tem sido associada a doenças ósseas, diversas doenças metabólicas, traumas de alta energia e distúrbios convulsivos. Sua ocorrência após trauma mínimo é muito rara. Este artigo apresenta o caso de uma mulher de 66 anos de idade que sofreu fratura intracapsular bilateral do colo do fêmur após um deslize e queda em casa. Uma artroplastia total do quadril, bilateral e cimentada foi feita em um único momento, usando uma abordagem lateral direta, alternando as posições laterais direita e esquerda. Os autores relatam um resultado satisfatório, com Harris Hip Score de 98 após um ano, que persistiu até o último seguimento, aos 30 meses.

9.
Rev. bras. ortop ; 52(3): 363-365, May.-June 2017. graf
Artigo em Inglês | LILACS | ID: biblio-899144

RESUMO

ABSTRACT Simultaneous bilateral neck femur fracture is a rare entity that has been associated with underlying bone disease, various metabolic diseases, high-energy trauma, and seizure disorders. Its occurrence following minimal trauma is very rare. This article presents the case of a 66-year-old female who sustained bilateral intracapsular fracture neck femur following a slip and fall at home. Single-stage bilateral cemented total hip replacement was done using a direct lateral approach with alternate right and left lateral positions. The authors report a satisfactory outcome, with Harris hip score of 98 at one year, which persisted until her last follow-up at 30 months.


RESUMO A fratura simultânea bilateral do colo do fêmur é uma entidade rara que tem sido associada a doenças ósseas, diversas doenças metabólicas, traumas de alta energia e distúrbios convulsivos. Sua ocorrência após trauma mínimo é muito rara. Este artigo apresenta o caso de uma mulher de 66 anos que sofreu fratura intracapsular bilateral do colo do fêmur após um deslize e queda em casa. Uma artroplastia total do quadril, bilateral e cimentada foi feita em um único momento, com o uso de uma abordagem lateral direta, em que se alternaram as posições lateral direita e esquerda. Os autores relatam um resultado satisfatório, com Harris Hip Score de 98 após um ano, que persistiu até o último seguimento, aos 30 meses.


Assuntos
Idoso , Artroplastia de Substituição , Fraturas do Colo Femoral , Quadril
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA