RESUMO
OBJECTIVE: To assess the association between two colposcopic indices, the Swede score and the 2011 International Federation of Cervical Pathology and Colposcopy (IFCPC) Nomenclature as well as to determine the efficacy of the Swede score with cutoffs of 7 and 8. METHODS: In the present cross-sectional pilot study, 34 women who had at least 1 colposcopy-directed biopsy due to abnormal cytology were enrolled. The colposcopic findings were scored by both the Swede score and the 2011 IFCPC Nomenclature and were compared with each other. The Kappa coefficient and the McNemar test were used. Accuracy, sensitivity, specificity, and positive and negative predictive values (NPV and PPV, respectively) were calculated, as well as the effectiveness with cutoffs of 7 and 8 in identifying cervical intraepithelial neoplasm (CIN) 2+ when using the Swede score. RESULTS: The correlation between the 2 colposcopic indices was 79.41%. The Kappa coefficient and the McNemar p-value were 0.55 and 0.37, respectively. The IFCPC Nomenclature had sensitivity, specificity, accuracy, PPV, and NPV of 85.71, 55.00, 67.64, 57.14, and 84.61%, respectively. The Swede score had sensitivity, specificity, accuracy, PPV, and NPV of 100, 63.15, 79.41, 68.18, and 100%, respectively. A Swede score cutoff of 7 for CIN 2+ detection had a specificity of 94.73%, while with a cutoff of 8 it increased to 100%. The sensitivity for both values was 60%. The PPV and NPV for cutoffs of 7 and 8 were 90 and 75 and 100 and 76%, respectively. CONCLUSION: Although both colposcopic indices have good reproducibility, the Swede score showed greater accuracy, sensitivity, and specificity in identifying CIN 2 + , especially when using a cutoff of 8.
OBJETIVO: Avaliar a associação entre dois índices colposcópicos, o escore Swede e a Nomenclatura International Federation of Cervical Pathology and Colposcopy (IFCPC, na sigla em inglês) 2011, assim como determinar a eficácia do escore Swede com os pontos de corte 7 e 8. MéTODOS: Trata-se de um estudo transversal, com 34 mulheres incluídas, que realizaram colposcopia com biópsia dirigida devido a uma citologia anormal. Os achados colposcópicos foram categorizados pelo escore Swede e pela Nomenclatura IFCPC 2011 e comparados um com o outro. Foram avaliados o coeficiente Kappa e o teste de McNemar e foram calculados a acurácia, a sensibilidade, a especificidade e valores preditivos negativos e positivos (VPN e VPP, respectivamente) de cada índice, assim como a eficácia com os pontos de corte 7 e 8 do escore Swede para determinar as lesões de neoplasia intraepitelial cervical (NIC) 2 + . RESULTADOS: A concordância entre os 2 índices foi de 79,41% e o coeficiente Kappa e o valor-p do teste de McNemar foram 0.55 e 0.37, respectivamente. Pela Nomenclatura IFCPC 2011, obtivemos como sensibilidade, especificidade, acurácia, VPP e VPN, respectivamente: 85,71, 55,00, 67,64, 57,14 e 84,61%. Pelo escore Swede obtivemos como sensibilidade, especificidade, acurácia, VPP e VPN, respectivamente: 100, 63,15, 79,41, 68,18 e 100%. O uso do escore Swede para detecção das lesões NIC 2+ obteve como especificidade 94,73% com o valor de corte de 7, enquanto o valor de corte 8 obteve 100%. A sensibilidade para ambos os cortes foi de 60%. O VPP e o VPN com os cortes 7 e 8 foram, respectivamente: 90,00 e 75,00 e 100,00 e 76,00%. CONCLUSãO: Ambos os índices colposcópicos tiveram boa reprodutibilidade; no entanto, o escore Swede mostrou melhor acurácia, sensibilidade e especificidade em identificar as lesões NIC 2+ e o melhor ponto de corte para identificar as lesões NIC2+ foi com o valor 8.
Assuntos
Displasia do Colo do Útero , Neoplasias do Colo do Útero , Gravidez , Feminino , Humanos , Colposcopia , Estudos Transversais , Projetos Piloto , Reprodutibilidade dos Testes , Neoplasias do Colo do Útero/diagnóstico , Displasia do Colo do Útero/diagnósticoRESUMO
Abstract Objective To assess the association between two colposcopic indices, the Swede score and the 2011 International Federation of Cervical Pathology and Colposcopy (IFCPC) Nomenclature as well as to determine the efficacy of the Swede score with cutoffs of 7 and 8. Methods In the present cross-sectional pilot study, 34 women who had at least 1 colposcopy-directed biopsy due to abnormal cytology were enrolled. The colposcopic findings were scored by both the Swede score and the 2011 IFCPC Nomenclature and were compared with each other. The Kappa coefficient and the McNemar test were used. Accuracy, sensitivity, specificity, and positive and negative predictive values (NPV and PPV, respectively) were calculated, as well as the effectiveness with cutoffs of 7 and 8 in identifying cervical intraepithelial neoplasm (CIN) 2+ when using the Swede score. Results The correlation between the 2 colposcopic indices was 79.41%. The Kappa coefficient and the McNemar p-value were 0.55 and 0.37, respectively. The IFCPC Nomenclature had sensitivity, specificity, accuracy, PPV, and NPV of 85.71, 55.00, 67.64, 57.14, and 84.61%, respectively. The Swede score had sensitivity, specificity, accuracy, PPV, and NPV of 100, 63.15, 79.41, 68.18, and 100%, respectively. A Swede score cutoff of 7 for CIN 2+ detection had a specificity of 94.73%, while with a cutoff of 8 it increased to 100%. The sensitivity for both values was 60%. The PPV and NPV for cutoffs of 7 and 8 were 90 and 75 and 100 and 76%, respectively. Conclusion Although both colposcopic indices have good reproducibility, the Swede score showed greater accuracy, sensitivity, and specificity in identifying CIN 2 + , especially when using a cutoff of 8.
Resumo Objetivo Avaliar a associação entre dois índices colposcópicos, o escore Swede e a Nomenclatura International Federation of Cervical Pathology and Colposcopy (IFCPC, na sigla em inglês) 2011, assim como determinar a eficácia do escore Swede com os pontos de corte 7 e 8. Métodos Trata-se de um estudo transversal, com 34 mulheres incluídas, que realizaram colposcopia com biópsia dirigida devido a uma citologia anormal. Os achados colposcópicos foram categorizados pelo escore Swede e pela Nomenclatura IFCPC 2011 e comparados um com o outro. Foram avaliados o coeficiente Kappa e o teste de McNemar e foram calculados a acurácia, a sensibilidade, a especificidade e valores preditivos negativos e positivos (VPN e VPP, respectivamente) de cada índice, assim como a eficácia com os pontos de corte 7 e 8 do escore Swede para determinar as lesões de neoplasia intraepitelial cervical (NIC) 2 + . Resultados A concordância entre os 2 índices foi de 79,41% e o coeficiente Kappa e o valor-p do teste de McNemar foram 0.55 e 0.37, respectivamente. Pela Nomenclatura IFCPC 2011, obtivemos como sensibilidade, especificidade, acurácia, VPP e VPN, respectivamente: 85,71, 55,00, 67,64, 57,14 e 84,61%. Pelo escore Swede obtivemos como sensibilidade, especificidade, acurácia, VPP e VPN, respectivamente: 100, 63,15, 79,41, 68,18 e 100%. O uso do escore Swede para detecção das lesões NIC 2+ obteve como especificidade 94,73% com o valor de corte de 7, enquanto o valor de corte 8 obteve 100%. A sensibilidade para ambos os cortes foi de 60%. O VPP e o VPN com os cortes 7 e 8 foram, respectivamente: 90,00 e 75,00 e 100,00 e 76,00%. Conclusão Ambos os índices colposcópicos tiveram boa reprodutibilidade; no entanto, o escore Swede mostrou melhor acurácia, sensibilidade e especificidade em identificar as lesões NIC 2+ e o melhor ponto de corte para identificar as lesões NIC2+ foi com o valor 8.
Assuntos
Humanos , Feminino , Neoplasias do Colo do Útero , Colposcopia , Lesões Intraepiteliais Escamosas , PapillomaviridaeRESUMO
BACKGROUND: Iron supplementation is a common recommendation to chronic kidney disease patients undergoing hemodialysis (HD). However, iron excess is closely associated with lipid peroxidation and, it is well known that electronegative low-density lipoproteins (LDL[-]) are present at higher plasma concentrations in diseases with high cardiovascular risk such as chronic kidney disease. Thus, the aim of this study was to investigate whether ferritin levels are associated with LDL(-) levels in HD patients. DESIGN: This was a cross-sectional study. SETTING: This study was conducted from a private clinic in Rio de Janeiro, Brazil. PATIENTS: The study included 27 HD patients and 15 healthy subjects. METHODS AND PROCEDURES: Twenty-seven HD patients (14 men, 58.6 ± 10 years, 62.2 ± 51.4 months on dialysis, and body mass index: 24.4 ± 4.2 kg/m(2)) were studied and compared with 15 healthy individuals (6 men, 53.8 ± 15.4 years, body mass index: 24.5 ± 4.3 kg/m(2)). Serum LDL(-) levels were measured using the enzyme-linked immunosorbent assay method; ferritin levels by commercially available kits, and tumor necrosis factor-α, interleukin-6, monocyte chemoattractant protein-1, and plasminogen activator inhibitor-1 were determined with a multiplex assay kit manufactured by R&D Systems. RESULTS: The HD patients presented higher LDL(-) and tumor necrosis factor-α levels (0.15 ± 0.13 U/L and 5.9 ± 2.3 pg/mL, respectively) than healthy subjects (0.07 ± 0.05 U/L and 2.3 ± 1.3 pg/mL, respectively) (P = .0001). The mean ferritin level in HD patients was 1,117.5 ± 610.4 ng/mL, and 90% of patients showed ferritin levels exceeding 500 ng/mL. We found a positive correlation between LDL(-) and ferritin in the patients (r = 0.48; P = .01), and ferritin was a significant contributor to LDL(-) concentrations independent of inflammation. CONCLUSIONS: Excess body iron stores for HD patients was associated with signs of increased oxidative stress, as reflected by increased LDL(-) levels in HD patients.