Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Animals (Basel) ; 14(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38891575

RESUMO

The thyroid of dogs has not been extensively studied in 2D shear-wave elastography, making it challenging to apply this technique in the diagnosis of thyroid diseases in a non-invasive manner. The aim of this study is to evaluate the thyroid glands of healthy dogs using 2D shear-wave elastography in order to establish qualitative and quantitative parameters of tissue stiffness in dogs in different age groups. A total of 31 dogs of various breeds, sexes, and sizes were evaluated. Animals with clinical signs or ultrasound findings indicative of endocrine disease or thyroid lesions were excluded from the study. The shear-wave velocity data in meters per second (m/s) and color elastograms were evaluated and calculated using QelaXto™ 2D software. A healthy thyroid exhibits a blue-color elastogram, indicative of low stiffness. The reference range for the shear-wave velocity of thyroid tissue assessed by 2D shear-wave elastography can be between 1.6 and 2.0 m/s, with a variation of ±0.889 in adult and senior dogs.

2.
Animals (Basel) ; 13(11)2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37889644

RESUMO

The high incidence of mammary tumors in small animals is concerning. Patient history, clinical examination, physical evaluation, and imaging studies are important for clinical staging. Ultrasonography is commonly applied to investigate the presence of abdominal metastasis. However, it has been shown to provide important information regarding mammary tumors' architecture and advanced sonographic techniques can provide information regarding neovascularization, stiffness, and perfusion. Different techniques have been investigated to determine accuracy to predict the lesions' histological classification. This paper reviews the information regarding each sonographic technique in the evaluation of mammary tumors, describing the most common findings and their potential to accurately assess and predict malignancy. Even though the gold standard for the diagnosis of mammary lesions is the histopathological examination, some ultrasonographic features described can predict the potential of a lesion being malignant. Among the different sonographic techniques, elastography can be considered the most reliable modality to accurately differentiate benign from malignant tumors when malignant lesions present increased stiffness. However, the combination of all sonographic techniques can provide important information that can lead to a better therapeutic approach and clinical staging. Furthermore, the potential of the sonographic study, especially CEUS to monitor therapeutic progression, demonstrate the need of further studies.

3.
BMC Vet Res ; 19(1): 181, 2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37784120

RESUMO

BACKGROUND: Canine hip dysplasia is a common orthopedic disease in veterinary practice. The diagnosis is made by radiographic examinations that evaluate bone alterations associated with hip dysplasia. Although radiographic examination is the gold standard for diagnosis, it does not allow a detailed evaluation of soft tissues such as the joint capsule and periarticular muscles. This study aimed to evaluate the accuracy of B-mode ultrasonography and acoustic radiation force impulse (ARFI) elastography in assessing the joint capsule and periarticular muscles of dogs using the Orthopedic Foundation of Animals (OFA) classification and the distraction index (DI) in the early and late diagnosis of hip dysplasia. This study sought to propose a protocol for the ultrasonographic evaluation of the structures involved in canine hip dysplasia. METHODS: Radiographic and ultrasonographic evaluations were performed on 108 hip joints of 54 dogs. Thirty dogs were older than 2 years and 24 were aged between 4 and 10 months. RESULTS: It was verified that an increase in pectineus muscle stiffness (cutoff value > 2.77 m/s) by elastography in some dysplastic dogs and an increase in the thickness of the joint capsule (cutoff value > 0.9 mm) in B-mode ultrasonography, were associated with a distraction index > 0.5, with both having a positive correlation. In B-mode ultrasonographic evaluation, the presence of signs of degenerative joint disease, such as irregularities of the cranial edge of the acetabulum and femoral head, were associated with a distraction index > 0.5 in canines, with a specificity of 94%. In adult dogs, the findings of degenerative joint disease on ultrasound were associated with a diseased OFA classification (P < 0.05). Measurement of the joint capsule > 1.10 mm was diagnostic for dysplasia in unhealthy dogs by OFA. CONCLUSIONS: ARFI elastography has shown that the pectineus muscle may experience changes in stiffness in dysplastic animals. Additionally, changes in joint capsule thickness can be identified in B-mode in young and adult dogs with dysplastic joints, which contributes to the diagnosis of hip dysplasia.


Assuntos
Doenças do Cão , Técnicas de Imagem por Elasticidade , Luxação do Quadril , Displasia Pélvica Canina , Animais , Cães , Displasia Pélvica Canina/diagnóstico por imagem , Displasia Pélvica Canina/complicações , Técnicas de Imagem por Elasticidade/veterinária , Luxação do Quadril/complicações , Luxação do Quadril/veterinária , Articulação do Quadril/diagnóstico por imagem , Ultrassonografia/veterinária , Doenças do Cão/diagnóstico por imagem
4.
BMC Vet Res ; 19(1): 180, 2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37777757

RESUMO

BACKGROUND: Sepsis is a condition characterized by organic dysfunction, leading to hemodynamic instability and high morbidity and mortality rates in humans and animals. Early identification of perfusion changes and appropriate management of sepsis are crucial for improving patient prognosis. Currently, the Systemic Inflammatory Response Syndrome (SIRS) and Sequential Organ Failure Assessment (SOFA) scores are widely studied for sepsis identification and evaluation of organ dysfunction. However, these scores do not assess gastrointestinal involvement, which is common in this condition. Contrast-enhanced ultrasound (CEUS) and Doppler have been considered promising diagnostic techniques for detecting changes in vascularization and microcirculation in a non-invasive and safe manner, particularly in the gastrointestinal system. This study aimed to evaluate duodenal perfusion using CEUS, as well as abdominal aortic and cranial mesenteric artery blood flow using Doppler ultrasound, and systolic arterial pressure (SAP) in 17 bitches with pyometra and in 10 healthy animals. RESULTS: The variables were compared between the pyometra and control groups, as well between patients with and without sepsis determined by the SOFA or SIRS scores. Pyometra was found to cause a reduction in abdominal aortic blood flow volume, aortic peak systolic velocity, and resistivity index as evaluated by Doppler ultrasound. Patients with sepsis according to the SOFA criteria only presented lower SAP. In contrast, sepsis animals identified by the SIRS score exhibited lower SAP, aortic peak systolic velocity, aortic blood flow volume, and aortic resistivity index and additionally, higher peak intensity of contrast in the duodenal wall. CONCLUSIONS: Pyometra causes a reduction in abdominal aortic blood flow, which is more pronounced in animals with sepsis identified by the SIRS criteria. These animals also exhibited a decrease in systolic blood pressure and an increase in duodenal perfusion, as evident by CEUS. However, these changes were not observed in patients with sepsis identified by the SOFA criteria. The alterations in intestinal perfusion observed in animals with sepsis indicate the presence of inflammation or dysfunction. In this regard, CEUS proves to be a valuable technique for detecting subtle changes in tissue hemodynamics that may not be apparent in conventional exams.


Assuntos
Doenças do Cão , Piometra , Sepse , Feminino , Humanos , Animais , Cães , Piometra/veterinária , Sepse/diagnóstico por imagem , Sepse/veterinária , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico por imagem , Síndrome de Resposta Inflamatória Sistêmica/veterinária , Ultrassonografia Doppler , Prognóstico , Perfusão/veterinária , Estudos Retrospectivos , Doenças do Cão/diagnóstico por imagem
5.
Anim Reprod ; 20(2): e20220110, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37416868

RESUMO

The aim of this study was to investigate uterine involution using ultrasonography techniques during postpartum. Postpartum ultrasonography evaluation (B-mode, color Doppler and Acoustic Radiation Force Impulse elastography) of the uterus was performed by transabdominal approach at immediate after birth and sequentially every 48 hours, during 30 days. The uterine echotexture did not present significant variations (P >0.05) being homogeneous in most evaluations; echogenicity of the uterus increased along the evaluation period (P =0.0452). Progressive and remarkable decrease of the total uterine diameter (UD) were observed (P <0.0001), especially during the first days postpartum. The thickness of uterine wall gradually decreased, as well the endometrial, myometrium and lumen diameters (P <0.0001). Uterine blood flow was assessed by Doppler and decreased during postpartum period, being significantly lower (P=0.0225) on the 30th day of postpartum. Uterine parenchyma presented as homogeneous dark areas (not deformable) on qualitative ultrasound elastography and the means shear velocity values of the uterine wall on quantitative elastography did not differ. This is the first study that evaluate the stiffness of uterine wall in healthy ewes, providing baseline data about quantitative and qualitative stiffness of the normal uterus, and it may be a useful tool for early diagnosis of uterine alterations during the postpartum period, using the reference parameter established for the assessment of uterine integrity during postpartum period.

6.
Anim Reprod ; 20(1): e20230006, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37101426

RESUMO

The aim of this study was to evaluate and correlate modifications of vaginal mucous impedance, vulvar temperature and ultrasonographic measurements (echobiometric parameters) to parturition in pregnant Saanen does. 30 does were selected for the study and submitted to an estrus synchronization protocol and natural mating. The females were evaluated daily from Day 143 of pregnancy to parturition. For the sonographic evaluations, the following structures were measured: biparietal diameter, thoracic diameter, abdominal diameter, ocular orbit, kidney length, kidney height, cardiac area, placentome length, cervical measurement and fetal heart rate; by means of two different approaches: transrectal and transabdominal, using a 7.5 MHz linear transducer. The vaginal mucous impedance was assessed using an electric estrous detector and vulvar temperature was measured using a non-contact infrared thermometer. Statistical analysis was performed using the R-project software and the significance level was set at 5% for all tests. 25 Saanen does became pregnant, resulting in 80.33% pregnancy rate. Fetal heart rate was negatively correlated to the hours to parturition (p<0,001; r-Pearson= -0,451), as well as vaginal temperature (p= 0,001; r-Pearson= -0,275), while cervical thickness was positively correlated to hours to parturition (p<0,001; r-Pearson= 0,490). The echobiometric parameters (biparietal diameter, thoracic diameter, abdominal diameter, ocular orbit, kidney length and height, cardiac area, placentome length), as well as vaginal mucous impedance did not vary throughout the timepoints of evaluation and did not correlate to the moment of parturition. It was concluded that the parameters of fetal heartbeat, vaginal temperature and cervical effacement in the last week of pregnancy provide valuable information regarding the proximity of parturition.

7.
Theriogenology ; 198: 224-230, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36610372

RESUMO

The aim of this study was to evaluate B-mode ultrasonography and ARFI elastography of the central nervous system of canine fetuses as complementary methods to predict gestational age, monitor fetal development and establish standards. Ultrasound examinations were performed on 26 English Bulldog bitches at 34, 49 and 60 days of gestation. The circumference (C), area (A) and diameters of the short (D1) and long (D2) axis of the two cerebral hemispheres of the fetuses in cross-section were measured. Fetal cerebellum shape, echotexture, echogenicity, and transverse diameter (TCD) were evaluated in cross-section. Elastography was performed obtaining color elastograms and mean shear wave velocity (SWV m/s) of the fetal brain and cerebellar tissues. Ultrasound variables were correlated with gestational day (GD). Brain masses had a circular to oval shape, hyperechoic echogenicity, and homogeneous echotexture. C and D1 were the more accurate variables to predict gestational day, with the formulas: GD = 19.38 + 2,06∗C (R2 = 81%) and GD = 18.93 + 7.45∗D1 (R2 = 82%). Cerebellum had a "banana" shape, with hyperechogenic edges, hypoechoic echogenicity, and homogeneous echotexture. The TCD (P = 0.0001) and cerebellar stiffness (P = 0.0006) were greater at 60 days than at 49 days of gestation. The brain mass SWV was correlated positively with GD (P = 0.0001) and showed a gradual increase (P = 0.0001) in the three gestational timepoints evaluated. According to qualitative elastography, both brain mass and cerebellum became more rigid over the course of gestational days. It was possible to verify the development of the brain and cerebellum of canine fetuses during pregnancy by ultrasonographic characteristics and B-mode dimensions, as well as by evaluating the elasticity of these tissues through elastography. These unpublished findings allow a better follow-up of the central nervous system development in the prenatal period and may help in future studies with canine fetuses that present cerebral and cerebellar abnormalities.


Assuntos
Técnicas de Imagem por Elasticidade , Gravidez , Feminino , Cães , Animais , Ultrassonografia Pré-Natal , Ultrassonografia , Feto , Cerebelo/diagnóstico por imagem , Idade Gestacional
8.
Acta Vet. Brasilica ; 17(1): 21-27, 2023. tab
Artigo em Inglês | VETINDEX | ID: biblio-1436292

RESUMO

Laparoscopy procedures are useful tools to perform some assisted reproductive biotechnologies in ewes, it requi-res general anesthesia and manoeuvres that might result in alteration of the cardiopulmonary function. For this reason, this study aimed to investigate the effects of oxygen supplementation as a therapeutic measure to mitigate these alterations in ewes submitted to laparoscopic ovum pick-up (LOPU) under total intravenous anesthesia (TIVA). Twenty-four healthy adult ewes were submitted to two LOPUs with a 21 days interval, under ketamine-midazolam anesthesia, and receiving each of the two experimental in random order, oxygen treatment (OT) 50 mL/kg/min of oxygen via endotracheal tube and control treatment (CT) not receive any inhalation treatment. Heart rate (HR), respiratory rate (fR), peripheral oxygen saturation (SpO2), mean arterial pressure (MAP), rectal temperature (RT), end-tidal CO2 concentration (EtCO2) and recovery anesthesia time were evaluated during LOPU, arterial blood gases and electrolytes were evaluated after induction of anesthesia and at the end of the LOPU. Variables were compared between groups and moments using ANOVA. MAP, SpO2, PaO2, SaO2 and pH were higher in OT, while EtCO2, PaCO2, temperature loss and recovery time were lower. These results allow to conclude that oxy-gen supplementation in ewes submitted to LOPU under TIVA provides benefits in order to mitigate physiological alterations.(AU)


Os procedimentos de laparoscopia são ferramentas úteis para realizar algumas biotecnologias de reprodução assistida em ovelhas, requer anestesia geral e manobras que podem resultar em alteração da função cardiopulmonar. Por esse motivo, este estudo teve como objetivo investigar os efeitos da suplementação de oxigênio como medida terapêutica para atenuar as alterações em ovelhas submetidas à Aspiração Folicular guiada por Laparoscopia (LOPU) sob anestesia venosa total (TIVA). Vinte e quatro ovelhas adultas saudáveis foram submetidas a duas LOPUs com intervalo de 21 dias, sob anestesia com cetamina-midazolam, recebendo cada um dos dois experimentos em ordem aleatória, tratamento com oxigênio (OT) 50 mL/kg/min de oxigênio via tubo endotraqueal e tratamento de controle (CT) não recebem nenhum tratamento por inalação. Frequência cardíaca (FC), frequência respiratória (FR), saturação periférica de oxigênio (SpO2), pressão arterial média (PAM), temperatura retal (TR), concentração expirada de CO2 (EtCO2) e tempo de recuperação da anestesia foram avaliados durante LOPU, arterial gasometria e eletrólitos foram avaliados após a indução da anestesia e ao final da COL. As variáveis foram comparadas entre grupos e momentos por meio de ANOVA. PAM, SpO2, PaO2, SaO2 e pH foram maiores no TO, enquanto EtCO2, PaCO2, perda de temperatura e tempo de recuperação foram menores. Estes resultados permitem concluir que a suplementação de oxigênio em ovelhas submetidas a LOPU sob TIVA proporciona benefícios no sentido de atenuar as alterações fisiológicas.(AU)


Assuntos
Animais , Oxigênio/efeitos adversos , Ovinos/cirurgia , Laparoscopia/veterinária , Anestesia Intravenosa/métodos , Biotecnologia , Ketamina/análise
9.
Anim. Reprod. (Online) ; 20(1): e20230006, 2023. graf, tab, ilus
Artigo em Inglês | VETINDEX | ID: biblio-1427296

RESUMO

The aim of this study was to evaluate and correlate modifications of vaginal mucous impedance, vulvar temperature and ultrasonographic measurements (echobiometric parameters) to parturition in pregnant Saanen does. 30 does were selected for the study and submitted to an estrus synchronization protocol and natural mating. The females were evaluated daily from Day 143 of pregnancy to parturition. For the sonographic evaluations, the following structures were measured: biparietal diameter, thoracic diameter, abdominal diameter, ocular orbit, kidney length, kidney height, cardiac area, placentome length, cervical measurement and fetal heart rate; by means of two different approaches: transrectal and transabdominal, using a 7.5 MHz linear transducer. The vaginal mucous impedance was assessed using an electric estrous detector and vulvar temperature was measured using a non-contact infrared thermometer. Statistical analysis was performed using the R-project software and the significance level was set at 5% for all tests. 25 Saanen does became pregnant, resulting in 80.33% pregnancy rate. Fetal heart rate was negatively correlated to the hours to parturition (p<0,001; r-Pearson= -0,451), as well as vaginal temperature (p= 0,001; r-Pearson= -0,275), while cervical thickness was positively correlated to hours to parturition (p<0,001; r-Pearson= 0,490). The echobiometric parameters (biparietal diameter, thoracic diameter, abdominal diameter, ocular orbit, kidney length and height, cardiac area, placentome length), as well as vaginal mucous impedance did not vary throughout the timepoints of evaluation and did not correlate to the moment of parturition. It was concluded that the parameters of fetal heartbeat, vaginal temperature and cervical effacement in the last week of pregnancy provide valuable information regarding the proximity of parturition.(AU)


Assuntos
Animais , Feminino , Gravidez , Prenhez , Cabras/fisiologia , Impedância Elétrica , Composição Corporal/fisiologia , Biometria/métodos , Ultrassonografia Pré-Natal/veterinária
10.
Anim. Reprod. (Online) ; 20(2): e20220110, 2023. tab, ilus, graf
Artigo em Inglês | VETINDEX | ID: biblio-1444259

RESUMO

The aim of this study was to investigate uterine involution using ultrasonography techniques during postpartum. Postpartum ultrasonography evaluation (B-mode, color Doppler and Acoustic Radiation Force Impulse elastography) of the uterus was performed by transabdominal approach at immediate after birth and sequentially every 48 hours, during 30 days. The uterine echotexture did not present significant variations (P >0.05) being homogeneous in most evaluations; echogenicity of the uterus increased along the evaluation period (P =0.0452). Progressive and remarkable decrease of the total uterine diameter (UD) were observed (P <0.0001), especially during the first days postpartum. The thickness of uterine wall gradually decreased, as well the endometrial, myometrium and lumen diameters (P <0.0001). Uterine blood flow was assessed by Doppler and decreased during postpartum period, being significantly lower (P=0.0225) on the 30th day of postpartum. Uterine parenchyma presented as homogeneous dark areas (not deformable) on qualitative ultrasound elastography and the means shear velocity values of the uterine wall on quantitative elastography did not differ. This is the first study that evaluate the stiffness of uterine wall in healthy ewes, providing baseline data about quantitative and qualitative stiffness of the normal uterus, and it may be a useful tool for early diagnosis of uterine alterations during the postpartum period, using the reference parameter established for the assessment of uterine integrity during postpartum period.(AU)


Assuntos
Animais , Feminino , Útero/crescimento & desenvolvimento , Ovinos/fisiologia , Ultrassonografia/métodos , Período Pós-Parto/fisiologia , Rigidez Muscular/veterinária
11.
Anim Reprod ; 19(3): e20220014, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36277482

RESUMO

The objective was to evaluate the blood flow of the uterine artery (UA) and umbilical artery (UMB) in the physiological pregnancy of goats by means of Doppler throughout the gestational period. Twenty-five Saanen goats weighing 55 ± 10 kg and aged between 2 and 5 were evaluated weekly, from the 21st until the 143rd day of gestation, and daily from that period until parturition. Values for peak systolic velocity (PSV), end diastolic velocity (EDV) and resistance (RI) and pulsatility (PI) indices of the uterine and umbilical arteries were determined. The values obtained were correlated with gestational age by Spearman's test, tested for adjustment to regression models and compared with the number of fetuses by ANOVA. The umbilical cord was first visualized at 28 days. Of the variables evaluated, RIUMB and PIUMB correlated with gestational age (p<0.001; and 0.046; respectively) and RIUMB had a low negative correlation with the number of fetuses per pregnancy (p = 0.003; r- Spearman = - 0.218). PSVUMB and EDVUMB values did not correlate with gestational age (p=0.737 and 0.768, respectively), but there was a decrease in the mean values throughout pregnancy (PSVUMB= 0.07; 0.31 and EDVUMB= 0.01; 0.06) as well as the change in the flow pattern of the spectral trace. The mean values of the uterine artery dopplervelocimetric variables PSVUT, EDVUT, PIUT and RIUT did not correlate with gestational age (p= 0.324; 0.372, 0.143; 0.13; respectively). It is expected that the results obtained will contribute to a broader understanding of the hemodynamic changes resulting from pregnancy in goats.

12.
Vet Radiol Ultrasound ; 63(6): 790-797, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35969229

RESUMO

The objectives of this prospective, experimental study were to describe changes in the stiffness of the equine superficial digital flexor tendon (SDFT) after induced injury, deep digital flexor tendon (DDFT), accessory ligament (AL-DDFT), and suspensory ligament (SL) during 90 days of healing using acoustic radiation force impulse (ARFI) elastography. Eight healthy horses were selected. Preinjury B mode and ARFI evaluations were performed bilaterally in the palmar metacarpal region. Injury was induced only on the left forelimb (G2) by a single injection of collagenase in SDFT, 15 cm distal to the accessory carpal bone. The right forelimb was used as a control (G1). Evaluations were performed at eight timepoints: one before injury (T0) and seven (T1-T7) after injury (3, 15, 30, 40, 60, 75, and 90 days post-induction). Tendinopathies were visualized as hypoechoic areas with loss of parallel tendon fiber pattern. Injured SDFTs presented mainly cool colors (soft) from T1 to T3, and from T4, there was an increase in warm colors (hard), close to the appearance of tendons of G1. In the first four timepoints, there was a decrease in stiffness compared to G1 (P < 0.001). On T1 and T2, a cutoff value <6.21 m/s to determine tendinopathy of the SDFT was established (75.8% sensitivity and 92.03% specificity). Stiffness changes in the DDFT, AL-DDFT, and SL of injured limbs occurred at different timepoints. Tendinopathy significantly altered the stiffness of the injured tendon and the adjacent tissues. ARFI made it possible to detect these changes, helping to monitor the reparation of this injury.


Assuntos
Técnicas de Imagem por Elasticidade , Doenças dos Cavalos , Tendinopatia , Cavalos , Animais , Membro Anterior/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/veterinária , Estudos Prospectivos , Tendões/diagnóstico por imagem , Tendinopatia/veterinária , Elasticidade , Doenças dos Cavalos/diagnóstico por imagem
13.
J Med Primatol ; 51(4): 201-212, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35546084

RESUMO

BACKGROUND: Marmosets are small arboreal primates. Knowledge of normal radiographic parameters and frequent disorders is limited. The objectives of this study were to evaluate possible variations between quantitative analyses and injuries to the appendicular and axial skeleton of Callithrix jacchus and Callithrix penicillata and their relationship with the environment. METHODS: Radiographic images of 29 marmosets were used. Skeletal lesions were described, long bones were measured, and pelvimetry, vertebrae, and sternebras were counted. RESULTS: Measurements of long bones and pelvimetry were similar between species. Evaluation of vertebrae and sternebras exhibited variations relative to the literature. Lesions on the skull, spine, thoracic and pelvic limbs were present in 48%, 54%, 44%, and 52% of marmosets, respectively. CONCLUSION: Skeletal disorders, especially of traumatic and metabolic origin, have a high prevalence in marmosets.


Assuntos
Callithrix , Callitrichinae , Animais
14.
Sci Rep ; 12(1): 4252, 2022 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-35277580

RESUMO

The objective was to evaluate the accuracy of B-mode ultrasonography and ARFI elastography in detecting malignancy in canine splenic lesions. Thirty-seven spleens with abnormalities (16 benign and 21 malignant) from dogs of different breeds and ages were evaluated. Echogenicity, echotexture, organ length and height were evaluated using B-mode. By ARFI elastography, tissue stiffness was evaluated qualitatively (elastogram) and quantitatively (measuring the shear wave velocity-SWV). Lesions were classified as diffuse, focal or multifocal (cranial, medial or caudal portion) and comparisons of the SWV between the injured and non-injured areas were performed. In the B-mode, no features were associated to malignancy (P > 0.05). In the elastogram, 35 spleens were non-deformable and 2 deformable, having no association with malignancy. The greater SWV was observed in malignant lesions (3.4 ± 0.6 m/s), followed by areas free from alterations (2.1 ± 0.3 m/s) and benign lesions (1.7 ± 0.5 m/s), with difference between groups (P < 0.0001). It was found that a SWV > 2.6 m/s indicates malignancy of canine splenic lesions (sensitivity of 95%, specificity of 100%, PPV of 100%, NPV of 94% and accuracy of 97%), concluding that ARFI elastography is a promising technique for differentiating malignancy in these lesions.


Assuntos
Técnicas de Imagem por Elasticidade , Neuroblastoma , Esplenopatias , Animais , Cães , Técnicas de Imagem por Elasticidade/métodos , Sensibilidade e Especificidade , Esplenopatias/diagnóstico por imagem , Esplenopatias/veterinária , Ultrassonografia/veterinária
15.
BMC Vet Res ; 18(1): 10, 2022 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-34980124

RESUMO

BACKGROUND: Cutaneous and subcutaneous neoplasms are highly prevalent in dogs, ranging from benign to highly aggressive and metastatic lesions. The diagnosis is obtained through histopathology, however it is an invasive technique that may take a long time to obtain the result, delaying the beginning of the adequate treatment. Thus, there is a need for non-invasive tests that can help in the early diagnosis of this type of cancer. The aim of this study was to verify the accuracy of B-mode ultrasonography, Doppler, and ARFI elastography to predict malignancy in cutaneous and subcutaneous canine neoplasms. In addition, we aim to propose an ultrasonography evaluation protocol and perform the neoplasms characterization using these three proposed techniques. RESULTS: Twenty-one types of specific neoplasm were diagnosed, and using B-mode, we verified the association between heterogeneous echotexture, invasiveness, presence of hyperechoic spots, and cavity areas with malignancy. An increased pulsatility was verified in malignant neoplasms using Doppler (cut-off value > 0.93). When using the elastography, malignancy was associated with non-deformable tissues and shear wave velocity > 3.52 m/s. Evaluation protocols were proposed associating 4, 5, 6, or 7 malignancy predictive characteristics, and characterization was done for all tumors with at least two cases. CONCLUSIONS: We concluded that ultrasonography methods are promising and effective in predicting malignancy in these types of tumors, and the association of methods can increase the specificity of the results.


Assuntos
Doenças do Cão , Técnicas de Imagem por Elasticidade , Neoplasias , Ultrassonografia Doppler , Animais , Doenças do Cão/diagnóstico por imagem , Cães , Técnicas de Imagem por Elasticidade/veterinária , Neoplasias/diagnóstico por imagem , Neoplasias/veterinária , Sensibilidade e Especificidade , Ultrassonografia Doppler/veterinária
16.
Ciênc. anim. bras. (Impr.) ; 23: e-70728, 2022. ilus, tab, graf
Artigo em Inglês, Português | VETINDEX | ID: biblio-1370151

RESUMO

The use of tumescent anesthesia with lidocaine can provide better intra- and postoperative analgesia that would benefit extensive reconstructive surgery. However, lidocaine can interfere with the healing process. Therefore, this study aimed to assess the local interference of the healing of induced and closed skin defects in a geometric pattern associated with the use of tumescent anesthesia with lidocaine in rabbits. Furthermore, we assessed its influence on cardiorespiratory parameters and postoperative analgesia. This study included 27 rabbits divided into three groups: GC (without the use of tumescence), GS (use of tumescence with 0.9% NaCl solution), and GL (use of tumescent anesthesia with lidocaine). There was no statistically significant intergroup difference in any stage of the wound healing process on macroscopic evaluations, in the angiogenesis process, or in the process of collagenization and fibroblast deposition. There were significant differences in heart rate (lower in GL), respiratory rate (higher in GC), mean arterial pressure (higher in GL), and expired concentration of isoflurane (lower in GL). There was no significant intergroup difference in the von Frey filament test or the visual analog scale score used to evaluate postoperative analgesia. We concluded that tumescent anesthesia with lidocaine does not impair postoperative tissue repair. Its use features benefits such as reducing the volume of inhaled anesthetic, maintaining the anesthesia plan, stable heart and respiratory rates, and lower hypotension during the surgical procedure.


O uso da anestesia por tumescência com lidocaína pode proporcionar melhor analgesia transoperatória e pós-operatória, o que seria um benefício em cirurgias reconstrutivas extensas. Entretanto, a lidocaína pode interferir na cicatrização. Diante disso, delineou-se um estudo a fim de avaliar a interferência local da cicatrização de defeitos cutâneos induzidos e fechados em padrão de figura geométrica, associado ao emprego de anestesia por tumescência com lidocaína em coelhos. Ademais, avaliar sua influência em parâmetros cardiorrespiratórios e na analgesia pós-operatória. Foi realizado um estudo com 27 coelhos, separados em três grupos, compreendidos em GC (sem o emprego de tumescência), GS (emprego de tumescência com solução NaCl 0.9%) e GL (emprego de anestesia por tumescência com lidocaína). Não houve diferença estatística em nenhuma etapa do processo cicatricial da ferida entre os grupos, tampouco nas avaliações macroscópicas, e no processo de angiogênese, ou ainda no processo de colagenização e deposição de fibroblastos. Houve diferença significativa na frequência cardíaca (menor no GL) e na respiratória (maior no GC), na pressão arterial média (maior no GL) e na concentração expirada de isoflurano (menor no GL). Não houve diferença significativa entre os grupos no teste de filamentos de von Frey e na Escala Visual Analógica, utilizados para avaliar a analgesia pós-operatória. Conclui-se que anestesia por tumescência com lidocaína não prejudica a regeneração tecidual após a cirurgia. O seu uso oferece benefícios como a diminuição do volume de anestésico inalatório, manutenção do plano anestésico, estabilidade das frequências cardíaca e respiratória, além de menor hipotensão durante o procedimento cirúrgico.


Assuntos
Animais , Feminino , Procedimentos de Cirurgia Plástica/reabilitação , Analgesia/métodos , Lidocaína/administração & dosagem , Coelhos
17.
Rev. bras. reprod. anim ; 46(1): 17-27, Janeiro-Março 2022. tab
Artigo em Português | VETINDEX | ID: biblio-1378025

RESUMO

O objetivo desta revisão foi descrever as principais técnicas de avaliação e achados ultrassonográficos da próstata canina. A ultrassonografia é o método de escolha para avaliação da glândula prostática, sendo imprescindível como auxílio no diagnóstico na detecção de anormalidades, principalmente quando há suspeita da presença de tumores. Com inovação dos equipamentos, surgiram técnicas complementares à ultrassonografia modo Bidimensional (B), tais como Doppler, ultrassonografia contrastada e elastografia, que aumentam a acurácia diagnóstica. O Doppler fornece informações sobre arquitetura vascular e aspectos hemodinâmicos dos vasos sanguíneos. A ultrassonografia contrastada permite determinar parâmetros relacionados à perfusão sanguínea das estruturas pelos agentes de contraste (ex.: microbolhas), definindo, portanto, padrões de alta e baixa intensidade da arquitetura vascular. A elastografia proporciona a avaliação da rigidez tecidual tanto de forma qualitativa, por meio de elastogramas, quanto quantitativa, por meio das velocidades de cisalhamento. Espera-se que esta revisão possa contribuir com informações relevantes aos leitores e veterinários da área de ultrassonografia e reprodução animal.(AU)


The purpose of this review was to describe the main assessment techniques and ultrasound findings of the canine prostate. Ultrasonography is the method of choice for assessing the prostate gland, being essential as an aid in the diagnosis in the detection of abnormalities, especially when the presence of tumors is suspected. With the innovation of the equipment, complementary techniques to B-mode ultrasonography have emerged, such as Doppler, contrasted ultrasound and elastography, which increase the diagnostic accuracy. Doppler provides information on vascular architecture and hemodynamic aspects of blood vessels. Contrast ultrasonography allows to determine parameters related to the blood perfusion of structures by contrast agents (eg, microbubbles), thus defining high and low intensity patterns of vascular architecture. ARFI elastography provides assessment of tissue stiffness both qualitatively, using elastograms, and quantitative, using shear speeds. It is hoped that this review can contribute with relevant information to readers and veterinarians in the area of asound and animal reproduction.(AU)


Assuntos
Animais , Cães , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Doppler/métodos , Equipamentos para Diagnóstico/veterinária , Técnicas de Imagem por Elasticidade/métodos , Vasos Sanguíneos/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Microbolhas/veterinária , Imagem de Perfusão/veterinária , Rigidez Vascular/fisiologia
18.
Acta sci. vet. (Impr.) ; 50: Pub. 1892, 2022. ilus
Artigo em Inglês | VETINDEX | ID: biblio-1401102

RESUMO

Background: Pelvic limb claudication is a common problem in dogs. However, determining the location of the lesion can be challenging. Diagnostic imaging is essential for identifying and evaluating muscle injuries. Ultrasonographic evaluation is frequently performed to identify muscle injuries. Although some muscle changes have already been described as ultrasonography findings in veterinary studies, little is known about the standardization of these muscle structures, especially in hip muscles. The objective of this study was to describe the normal ultrasound anatomy of the lateral and medial muscles of the pelvic limb and establish an unprecedented protocol for the evaluation of these structures. Materials, Methods & Results: A total of 4 lateral and 4 medial musculatures of the pelvic limb of dogs were evaluated using ultrasound. An initial ex vivo study (1st phase) was performed to delineate anatomical and ultrasonographic assessments. The 2nd experimental phase proceeded with the application of in vivo scanning. The same operator performed all anatomical and ultrasonographic assessments. The gluteus medius, vastus lateralis, tensor fasciae latae, sartorius, pectineus, gracilis, adductor, and rectus femoris muscles were evaluated in longitudinal and transverse planes. Ten paired hips from 5 cadavers consisting of 3 females (60%) and 2 males (40%) were evaluated during the exvivo phase. The average age and weight of the dogs were 3.6 ± 0.87 years and 21.9 ± 5.2 kg, respectively. The invivo study included 4 females (40%) and 6 males (60%), for a total of 10 healthy animals consisting of 20 hips; the mean weight was 30.11 ± 7.45 kg and the average age was 4.5 ± 2.75 years. All muscles maintained the same ultrasound pattern when compared with each other and between different groups in the invivo study. The longitudinal section presented a hypoechoic structure permeated by thin hyperechoic longitudinal striations. The hypoechoic aspect was maintained, with striae identified as hyperechogenic points in the cross-sectional view. Discussion: B-mode ultrasonographic evaluation with a high-frequency transducer has facilitated the identification of the lateral and medial muscles of the pelvic limbs of medium and large dogs exvivo and invivo. This approach is an effective and safe way to access these muscles, and aids in the establishment of an unprecedented protocol for ultrasound evaluation of this region. Understanding the normal ultrasonographic anatomy is essential to identify muscle injuries such as contractures, tumors, ruptures, and stretch, which can lead to loss of muscle echogenicity and echotexture. Furthermore, ultrasound standardization reduces inter-observer error, facilitates technique reproducibility, assists in a more assertive assessment, and directs the patient's most appropriate therapy. In addition, anatomical dissection with the aid of acoustic gel injection into the evaluated musculature is essential to guide the examination because it allows the confirmation of the structures. In this study, the ultrasound scans of 6 fundamental muscles (gluteus medius, tensor fasciae latae, gracilis, adductor, pectineus, and rectus femoris) for hip mobility and 2 knee muscles (sartorius and vastus lateralis) were standardized. Exvivo evaluations facilitated the application of invivo techniques, and no difficulties were found during these evaluations.


Assuntos
Animais , Cães , Pelve/patologia , Pelve/diagnóstico por imagem , Músculos/anatomia & histologia , Neoplasias Pélvicas/veterinária , Ultrassonografia/métodos , Ultrassonografia/veterinária
19.
Anim. Reprod. (Online) ; 19(3): e20220014, set. 2022. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1396857

RESUMO

The objective was to evaluate the blood flow of the uterine artery (UA) and umbilical artery (UMB) in the physiological pregnancy of goats by means of Doppler throughout the gestational period. Twenty-five Saanen goats weighing 55 ± 10 kg and aged between 2 and 5 were evaluated weekly, from the 21st until the 143rd day of gestation, and daily from that period until parturition. Values for peak systolic velocity (PSV), end diastolic velocity (EDV) and resistance (RI) and pulsatility (PI) indices of the uterine and umbilical arteries were determined. The values obtained were correlated with gestational age by Spearman's test, tested for adjustment to regression models and compared with the number of fetuses by ANOVA. The umbilical cord was first visualized at 28 days. Of the variables evaluated, RIUMB and PIUMB correlated with gestational age (p<0.001; and 0.046; respectively) and RIUMB had a low negative correlation with the number of fetuses per pregnancy (p = 0.003; r- Spearman = - 0.218). PSVUMB and EDVUMB values did not correlate with gestational age (p=0.737 and 0.768, respectively), but there was a decrease in the mean values throughout pregnancy (PSVUMB= 0.07; 0.31 and EDVUMB= 0.01; 0.06) as well as the change in the flow pattern of the spectral trace. The mean values of the uterine artery dopplervelocimetric variables PSVUT, EDVUT, PIUT and RIUT did not correlate with gestational age (p= 0.324; 0.372, 0.143; 0.13; respectively). It is expected that the results obtained will contribute to a broader understanding of the hemodynamic changes resulting from pregnancy in goats.(AU)


Assuntos
Animais , Feminino , Gravidez , Artérias Umbilicais/diagnóstico por imagem , Cabras/anatomia & histologia , Ultrassonografia Doppler/veterinária , Artéria Uterina/diagnóstico por imagem , Circulação Placentária/fisiologia
20.
Anim Reprod ; 18(2): e20210002, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34276816

RESUMO

The aim of this study was to evaluate the blood flow of the uterine artery, fetal aorta and umbilical artery in the physiological pregnancy of sheep by means of pulsed Doppler throughout the gestational period. Thirty Santa Inês ewes weighing between 45.4±4.3 kg and aged 2 to 5 years were selected. The evaluations were carried out weekly from the 3rd to the 21st gestational week. Peak systolic velocity (PSV), end diastolic velocity (EDV) and resistance index (RI) were obtained. Analysis of variance was performed, and the minimum significant comparison of means was obtained by the BH test with adjusted P<0.05. The results were expressed as mean ± standard error. For the fetal aorta, there was an increase in the EDV values and a decrease in the PSV and RI throughout pregnancy. For the uterine artery, PSV and EDV did not present significant variation, whereas the RI showed a reduction in the last week. Increased EDV values were found for the umbilical artery throughout pregnancy. For the PSV there was no significant difference, as the RI was reduced at the end of pregnancy. The results obtained are expected to contribute to a more complete understanding of the hemodynamic changes resulting from pregnancy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA