Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Intern Med J ; 53(4): 492-496, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36053990

RESUMO

BACKGROUND: Suspected organising pneumonia (OP) is a common finding in patients with severe coronavirus disease 2019 (COVID-19), but the impact on outcomes of the radiological patterns of diffuse parenchymal lung disease on outcome of these patients is still uncertain. AIMS: Investigate the presence of radiological images compatible with OP and its association with clinical outcomes in patients with COVID-19 submitted to invasive mechanical ventilation (IMV). METHODS: Retrospective, unicentric cohort study composed of patients who required IMV and underwent chest computerized tomography to investigate secondary complications of COVID-19. We compared patients with radiological findings characteristic of suspected OP with those without this condition. The main outcome was hospital mortality. RESULTS: Two hundred and ten patients were included, and 65 had signals compatible with OP. All patients with suspected OP were treated with corticosteroids. There was no difference in IVM-free days until day 28 between the groups (median, 0 days; interquartile range [IQR], 0-14.8) in the group with suspected OP vs 0 days (IQR, 0-11) in the group without suspected OP (P = 0.14). In univariate analysis, the presence of suspected OP was associated with lower hospital mortality; however, after correction for potential confounding variables, it was not associated with the outcome, even after matching by propensity score in patients without this condition. CONCLUSION: OP radiologic pattern in patients with severe COVID-19 is not associated with worse outcomes.


Assuntos
COVID-19 , Doenças Pulmonares Intersticiais , Humanos , COVID-19/diagnóstico por imagem , Respiração Artificial , Estudos Retrospectivos , Estudos de Coortes , Prognóstico
2.
Intensive Crit Care Nurs ; 69: 103162, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34895796

RESUMO

PURPOSE: To verify whether there is an association between the Nursing Activities Score (NAS) on the day of discharge from the intensive care unit and readmission.. MATERIALS AND METHODS: A retrospective cohort study of all patients admitted to the intensive care unit of Hospital Ernesto Dornelles, Porto Alegre, Brazil, who were discharged to the ward from October 2018 to December 2019. We collected demographic and clinical variables of the patients and the Nursing Activities Scoreon the day of discharge. Patients were followed up until the day of hospital discharge or death. RESULTS: We included 1045 patients in the final sample. One hundred eighty-eight (18.0%) patients were readmitted, in addition there were two (0.2%) unexpected deaths that occurred in the ward. The median NAS was 59.9 (50.9-67.3), which was higher in the bivariate analysis in patients who were readmitted (64.0, 55.7-71.4) than in patients who were not readmitted (58.7, 49.7-66.1) (p < 0.001). Patients with a Nursing Activities Score  ≥ 60.0 and < 60.0 had rates of readmission of 23.4% and 12.7%, respectively (p < 0.001). After multivariable adjustment, the Nursing Activities Score at discharge maintained an association with readmission. In addition, in the Cox regression, the Nursing Activities Score as a dichotomous variable was independently associated with readmission (adjusted HR 1.560; CI 1.146-2.125; p = 0.005). CONCLUSIONS: We found that the nursing workload, assessed by the Nursing Activities Score at the time of discharge from the intensive care unit, was associated with risk of readmission..


Assuntos
Alta do Paciente , Readmissão do Paciente , Humanos , Unidades de Terapia Intensiva , Estudos Retrospectivos , Carga de Trabalho
5.
Arq Bras Endocrinol Metabol ; 57(8): 636-41, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24343633

RESUMO

OBJECTIVE: To assess serum levels of the main factors that regulate the activation of the zona glomerulosa and aldosterone production in patients with septic shock, as well as their response to a high-dose (250 µg) adrenocorticotropic hormone (ACTH) stimulation test. SUBJECTS AND METHODS: In 27 patients with septic shock, baseline levels of aldosterone, cortisol, ACTH, renin, sodium, potassium, and lactate were measured, followed by a cortrosyn test. RESULTS: Renin correlated with baseline aldosterone and its variation after cortrosyn stimulation. Baseline cortisol and its variation did not correlate with ACTH. Only three patients had concomitant dysfunction of aldosterone and cortisol secretion. CONCLUSIONS: Activation of the zona glomerulosa and zona fasciculata are independent. Aldosterone secretion is dependent on the integrity of the renin-angiotensin-aldosterone system, whereas cortisol secretion does not appear to depend predominantly on the hypothalamic-pituitary-adrenal axis. These results suggest that activation of the adrenal gland in critically ill patients occurs by multiple mechanisms.


Assuntos
Aldosterona/sangue , Hidrocortisona/metabolismo , Renina/sangue , Choque Séptico/metabolismo , Zona Glomerulosa/metabolismo , Hormônio Adrenocorticotrópico/administração & dosagem , Adulto , Idoso , Cosintropina/administração & dosagem , Cosintropina/metabolismo , Feminino , Humanos , Sistema Hipotálamo-Hipofisário , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Sistema Hipófise-Suprarrenal , Estudos Prospectivos , Sistema Renina-Angiotensina , Choque Séptico/mortalidade , Choque Séptico/fisiopatologia , Zona Fasciculada
6.
Arq. bras. endocrinol. metab ; Arq. bras. endocrinol. metab;57(8): 636-641, Nov. 2013. graf, tab
Artigo em Inglês | LILACS | ID: lil-696904

RESUMO

OBJECTIVE: To assess serum levels of the main factors that regulate the activation of the zona glomerulosa and aldosterone production in patients with septic shock, as well as their response to a high-dose (250 µg) adrenocorticotropic hormone (ACTH) stimulation test. SUBJECTS AND METHODS: In 27 patients with septic shock, baseline levels of aldosterone, cortisol, ACTH, renin, sodium, potassium, and lactate were measured, followed by a cortrosyn test. RESULTS: Renin correlated with baseline aldosterone and its variation after cortrosyn stimulation. Baseline cortisol and its variation did not correlate with ACTH. Only three patients had concomitant dysfunction of aldosterone and cortisol secretion. CONCLUSIONS: Activation of the zona glomerulosa and zona fasciculata are independent. Aldosterone secretion is dependent on the integrity of the renin-angiotensin-aldosterone system, whereas cortisol secretion does not appear to depend predominantly on the hypothalamic-pituitary-adrenal axis. These results suggest that activation of the adrenal gland in critically ill patients occurs by multiple mechanisms.


OBJETIVO: Avaliar os níveis séricos dos principais fatores que regulam a ativação da zona glomerulosa e a produção de aldosterona em pacientes com choque séptico, assim como sua resposta ao teste de cortrosina em alta dose (250 µg). SUJEITOS E MÉTODOS: Em 27 portadores de choque séptico, foram aferidos níveis basais de aldosterona, cortisol, ACTH, renina, sódio, potássio e lactato, bem como realizado teste de cortrosina. RESULTADOS: Renina se correlacionou com níveis basais de aldosterona e sua variação após teste de cortrosina. Cortisol basal e sua variação não se correlacionaram com ACTH. Apenas três pacientes apresentaram disfunção concomitante da secreção de aldosterona e cortisol. CONCLUSÕES: Ativação das zonas fasciculada e glomerulosa são independentes. Secreção de aldosterona é dependente da integridade do sistema renina-angiotensina-aldosterona, enquanto secreção de cortisol não parece predominantemente dependente do eixo hipotálamo-hipófise-adrenal. Esses resultados sugerem que a ativação da adrenal em pacientes críticos ocorre por múltiplos mecanismos.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aldosterona/sangue , Hidrocortisona , Renina/sangue , Choque Séptico/metabolismo , Zona Glomerulosa , Hormônio Adrenocorticotrópico/administração & dosagem , Cosintropina/administração & dosagem , Cosintropina/metabolismo , Sistema Hipotálamo-Hipofisário , Estimativa de Kaplan-Meier , Sistema Hipófise-Suprarrenal , Estudos Prospectivos , Sistema Renina-Angiotensina , Choque Séptico/mortalidade , Choque Séptico/fisiopatologia , Zona Fasciculada
7.
J Bras Pneumol ; 36(5): 554-61, 2010.
Artigo em Inglês, Português | MEDLINE | ID: mdl-21085820

RESUMO

OBJECTIVE: To compare the influence of two different ventilation strategies-volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV)-on the functional performance of lung grafts in a canine model of unilateral left lung transplantation using donor lungs harvested after three hours of normothermic cardiocirculatory arrest under mechanical ventilation. METHODS: The study comprised 40 mongrel dogs, randomized into two groups: VCV and PCV. Of the 20 recipients, 5 did not survive the transplant, and 5 died before the end of the post-transplant assessment period. The remaining 10 survivors (5 in each group) were evaluated for 360 min after lung transplantation. The functional performance of the grafts was evaluated regarding respiratory mechanics, gas exchange, and lung graft histology. RESULTS: There were no significant differences between the groups regarding respiratory mechanics (peak inspiratory pressure, plateau pressure, mean airway pressure, dynamic compliance, and static compliance) or gas exchange variables (PaO2, venous oxygen tension, PaCO2, venous carbon dioxide tension, and the arterial-venous oxygen content difference). The histopathological findings were consistent with nonspecific acute lung injury and did not differ between the groups. CONCLUSIONS: This model of lung transplantation showed that the functional performance of lung grafts was not influenced by the ventilation strategy employed during the first six hours after reperfusion.


Assuntos
Transplante de Pulmão/fisiologia , Pulmão/fisiopatologia , Respiração Artificial/métodos , Animais , Cães , Pulmão/patologia , Transplante de Pulmão/métodos , Modelos Animais , Preservação de Órgãos , Distribuição Aleatória
8.
J. bras. pneumol ; J. bras. pneumol;36(5): 554-561, set.-out. 2010. ilus
Artigo em Português | LILACS | ID: lil-564197

RESUMO

OBJETIVO: Comparar a influência de duas estratégias ventilatórias - ventilação controlada a volume (VCV) e ventilação controlada a pressão (VCP) - no desempenho funcional de enxertos pulmonares em um modelo canino de transplante pulmonar unilateral esquerdo, utilizando-se doadores cujos pulmões foram captados após três horas de parada cardiocirculatória em temperatura ambiente e sob ventilação mecânica. MÉTODOS: O estudo incluiu 40 cães mestiços randomizados nos grupos VCV e VCP. Dos 20 receptores, 5 não sobreviveram ao transplante, e 5 não sobreviveram ao período de avaliação pós-transplante. Os 10 receptores sobreviventes (5 em cada grupo) foram avaliados durante 360 min após o término do transplante pulmonar. O desempenho funcional dos enxertos foi estudado através da avaliação da mecânica respiratória, trocas gasosas e histologia do enxerto. RESULTADOS: Não houve diferenças significativas entre os grupos quanto às variáveis de mecânica respiratória (pressão de pico inspiratória, pressão de platô, pressão média de vias aéreas, complacência dinâmica e complacência estática) e de trocas gasosas (PaO2, pressão venosa mista de oxigênio, PaCO2, pressão venosa mista de CO2 e diferença arteriovenosa de oxigênio). As alterações histopatológicas foram compatíveis com o padrão de lesão pulmonar aguda não específica e não diferiram entre os grupos. CONCLUSÕES: Este modelo de transplante pulmonar mostrou que o desempenho funcional do enxerto não foi influenciado pela estratégia ventilatória utilizada até seis horas após a reperfusão.


OBJECTIVE: To compare the influence of two different ventilation strategies-volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV)-on the functional performance of lung grafts in a canine model of unilateral left lung transplantation using donor lungs harvested after three hours of normothermic cardiocirculatory arrest under mechanical ventilation. METHODS: The study comprised 40 mongrel dogs, randomized into two groups: VCV and PCV. Of the 20 recipients, 5 did not survive the transplant, and 5 died before the end of the post-transplant assessment period. The remaining 10 survivors (5 in each group) were evaluated for 360 min after lung transplantation. The functional performance of the grafts was evaluated regarding respiratory mechanics, gas exchange, and lung graft histology. RESULTS: There were no significant differences between the groups regarding respiratory mechanics (peak inspiratory pressure, plateau pressure, mean airway pressure, dynamic compliance, and static compliance) or gas exchange variables (PaO2, venous oxygen tension, PaCO2, venous carbon dioxide tension, and the arterial-venous oxygen content difference). The histopathological findings were consistent with nonspecific acute lung injury and did not differ between the groups. CONCLUSIONS: This model of lung transplantation showed that the functional performance of lung grafts was not influenced by the ventilation strategy employed during the first six hours after reperfusion.


Assuntos
Animais , Cães , Transplante de Pulmão/fisiologia , Pulmão/fisiopatologia , Respiração Artificial/métodos , Transplante de Pulmão/métodos , Pulmão/patologia , Modelos Animais , Preservação de Órgãos , Distribuição Aleatória
9.
Intensive Care Med ; 33(10): 1840-7, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17673974

RESUMO

OBJECTIVE: To assess the accuracy of direct examination and quantitative cultures of BAL to diagnose pneumonia with or without antibiotic treatment. DESIGN: Experimental rat models. INTERVENTIONS: Pneumonia was induced by intratracheal inoculation of S. pneumoniae (10(9) cfu/ml) or P. aeruginosa (10(8)cfu/ml). Controls (n = 10) received sterile inoculum. Study animals received penicillin (n = 19) or saline (n = 18) (pneumococcal model); amikacin (n = 13), ceftazidime (n = 11), or saline (n = 13) (Pseudomonas model). BAL was assessed 48 h after infection. The animals were killed for histopathological analysis. RESULTS: All study animals developed pneumonia, which was more extensive in the pneumococcal than in the Pseudomonas model. In pneumococcal pneumonia the sensitivity of BAL cultures (10(3) cfu/ml or higher) was 77.8% with saline and 21.0% with penicillin. In the Pseudomonas ceftazidime group all specimens were negative, precluding diagnosis. The sensitivity of cultures with amikacin was 23.1% vs. 30.8% with saline. In the pneumococcal model intracellular organism (ICO) count of 2% or higher had a sensitivity of 100% for detecting pneumonia with saline and 57.9% with penicillin. In the Pseudomonas model the sensitivity of ICO was 69.2% with both amikacin and saline and 36.3% with ceftazidime. The sensitivity of neutrophil count above 50% in pneumococcal pneumonia was 77.8% and 64.7% with saline and penicillin, respectively, and 69.2%, 61.5%, and 81.8% with saline, amikacin, and ceftazidime, respectively, in Pseudomonas pneumonia. CONCLUSIONS: BAL-positive intracellular organisms were more accurate than cultures for the diagnosis of recent pneumonia, and were less affected by antibiotic treatment.


Assuntos
Líquido da Lavagem Broncoalveolar/citologia , Pneumonia Bacteriana/diagnóstico , Pneumonia Bacteriana/microbiologia , Animais , Antibacterianos/uso terapêutico , Técnicas Bacteriológicas , Líquido da Lavagem Broncoalveolar/microbiologia , Contagem de Colônia Microbiana , Pulmão/microbiologia , Pulmão/patologia , Pneumonia Bacteriana/tratamento farmacológico , Pneumonia Bacteriana/patologia , Pneumonia Pneumocócica/diagnóstico , Pneumonia Pneumocócica/tratamento farmacológico , Pneumonia Pneumocócica/microbiologia , Infecções por Pseudomonas/diagnóstico , Infecções por Pseudomonas/tratamento farmacológico , Infecções por Pseudomonas/microbiologia , Pseudomonas aeruginosa/isolamento & purificação , Ratos , Ratos Wistar , Sensibilidade e Especificidade , Streptococcus pneumoniae/isolamento & purificação
10.
J Heart Lung Transplant ; 23(2): 242-51, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14761773

RESUMO

BACKGROUND: The purpose of this study was to evaluate canine lungs obtained from non-heart-beating donors after unilateral lung transplantation subjected to partial liquid ventilation with perfluorodecalin. METHODS: Twelve donor dogs were killed and kept under mechanical ventilation for 3 hours. Heart-lung blocks were harvested after retrograde pulmonary hypothermic flush with Perfadex. Left lung grafts were randomly transplanted into 12 weight-matched recipient animals. Animals were divided into 2 groups: control (standard mechanical ventilation, n = 6) and PLV (partial liquid ventilation, n = 6). Forty-five minutes after transplantation, the animals in the PLV group received perfluorodecalin (15 ml/kg) via orotracheal tube. All animals received volume-controlled ventilation (FIO2) 1.0, PEEP 5 cm H(2)O) over 6 consecutive hours. Thereafter, blood-gas analysis, ventilatory mechanics and hemodynamics were registered at 30-minute intervals. After 6 hours of reperfusion the animals were killed and the transplanted lungs were extracted to obtain the wet/dry weight ratio. RESULTS: There were significant differences in pulmonary arterial pressure, which were higher in control group animals (p < 0.009). The control animals also showed higher arterial PaO(2) than those in the PLV group (p < 0.00001), but lower PaCO(2) (p < 0.008). The peak and plateau pressures were higher in the PLV group (p < 0.00001). Neither static compliance nor wet/dry weight ratios were different in between groups. CONCLUSIONS: PLV with perfluorodecalin yields functional results compatible with life in this model. Nonetheless, pulmonary gas exchange and mechanics were superior after reperfusion in animals given conventional mechanical ventilation up to 6 hours after left lung allotransplantation.


Assuntos
Substitutos Sanguíneos , Fluorocarbonos , Ventilação Líquida , Transplante de Pulmão , Animais , Estudos de Casos e Controles , Cães , Ventilação Líquida/métodos , Transplante de Pulmão/fisiologia , Troca Gasosa Pulmonar , Respiração Artificial , Mecânica Respiratória , Doadores de Tecidos , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA