RESUMO
Cestodes use own lipid-binding proteins to capture and transport hydrophobic ligands, including lipids that they cannot synthesise as fatty acids and cholesterol. In E. granulosus s.l., one of these lipoproteins is antigen B (EgAgB), codified by a multigenic and polymorphic family that gives rise to five gene products (EgAgB8/1-5 subunits) assembled as a 230 kDa macromolecule. EgAgB has a diagnostic value for cystic echinococcosis, but its putative role in the immunobiology of this infection is still poorly understood. Accumulating research suggests that EgAgB has immunomodulatory properties, but previous studies employed denatured antigen preparations that might exert different effects than the native form, thereby limiting data interpretation. This work analysed the modulatory actions on macrophages of native EgAgB (nEgAgB) and the recombinant form of EgAg8/1, which is the most abundant subunit in the larva and was expressed in insect S2 cells (rEgAgB8/1). Both EgAgB preparations were purified to homogeneity by immunoaffinity chromatography using a novel nanobody anti-EgAgB8/1. nEgAgB and rEgAgB8/1 exhibited differences in size and lipid composition. The rEgAgB8/1 generates mildly larger lipoproteins with a less diverse lipid composition than nEgAgB. Assays using human and murine macrophages showed that both nEgAgB and rEgAgB8/1 interfered with in vitro LPS-driven macrophage activation, decreasing cytokine (IL-1ß, IL-6, IL-12p40, IFN-ß) secretion and ·NO generation. Furthermore, nEgAgB and rEgAgB8/1 modulated in vivo LPS-induced cytokine production (IL-6, IL-10) and activation of large (measured as MHC-II level) and small (measured as CD86 and CD40 levels) macrophages in the peritoneum, although rEgAgB8/1 effects were less robust. Overall, this work reinforced the notion that EgAgB is an immunomodulatory component of E. granulosus s.l. Although nEgAgB lipid's effects cannot be ruled out, our data suggest that the EgAgB8/1 subunit contributes to EgAgB´s ability to regulate the inflammatory activation of macrophages.
Assuntos
Echinococcus granulosus , Humanos , Animais , Camundongos , Echinococcus granulosus/genética , Echinococcus granulosus/metabolismo , Interleucina-6/metabolismo , Lipopolissacarídeos/metabolismo , Ativação de Macrófagos , Lipoproteínas/genética , Lipoproteínas/metabolismo , Macrófagos , Citocinas/metabolismoRESUMO
Nanobodies are the smallest antibody fragments which bind to antigens with high affinity and specificity. Due to their outstanding physicochemical stability, simplicity and cost-effective production, nanobodies have become powerful agents in therapeutic and diagnostic applications. In this work, the advantages of nanobodies were exploited to develop generic and standardized anti-human IgM reagents for serology and IgM+ B-cell analysis. Selection of anti-IgM nanobodies was carried out by evaluating their yields, stability, binding kinetics and cross-reactivity with other Ig isotypes. High affinity nanobodies were selected with dissociation constants (KDs) in the nM range and high sensitivities for detection of total IgM by ELISA. The nanobodies also proved to be useful for capturing IgM in the serodiagnosis of an acute infection as demonstrated by detection of specific IgM in sera of dengue virus patients. Finally, due to the lack of an Fc region, the selected nanobodies do not require Fc receptor blocking steps, facilitating the immunophenotyping of IgM+ cells by flow cytometry, an important means of diagnosis of immunodeficiencies and B-cell lymphoproliferative disorders. This work describes versatile anti-IgM nanobodies that, due to their recombinant nature and ease of reproduction at low cost, may represent an advantageous alternative to conventional anti-IgM antibodies in research and diagnosis.
Assuntos
Anticorpos Anti-Idiotípicos , Indicadores e Reagentes , Anticorpos de Domínio Único , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina MRESUMO
Our group has previously developed immunoassays for noncompetitive detection of small molecules based on the use of phage borne anti-immunocomplex peptides. Recently, we substituted the phage particles by biotinylated synthetic anti-immunocomplex peptides complexed with streptavidin and named these constructs nanopeptamers. In this work, we report the results of combining AlphaLisa, a commercial luminescent oxygen channeling bead system, with nanopeptamers for the development of a noncompetitive homogeneous assay for the detection of small molecules. The signal generation of AlphaLisa assays relies on acceptor-donor bead proximity induced by the presence of the analyte (a macromolecule) simultaneously bound by antibodies immobilized on the surface of these beads. In the developed assay, termed as nanoAlphaLisa, bead proximity is sustained by the presence of a small model molecule (atrazine, MW = 215) using an antiatrazine antibody captured on the acceptor bead and an atrazine nanopeptamer on the donor bead. Atrazine is one of the most used pesticides worldwide, and its monitoring in water has relevant human health implications. NanoAlphaLisa allowed the homogeneous detection of atrazine down to 0.3 ng/mL in undiluted water samples in 1 h, which is 10-fold below the accepted limit in drinking water. NanoAlphaLisa has the intrinsic advantages for automation and high-throughput, simple, and fast homogeneous detection of target analytes that AlphaLisa assay provides.
Assuntos
Aptâmeros de Peptídeos/química , Atrazina/análise , Luminescência , Oxigênio/química , Triazinas/análise , Poluentes Químicos da Água/análise , Rios/químicaRESUMO
Single domain heavychain binders (nanobodies) obtained from camelid antibody libraries hold a great promise for immunoassay development. However, there is no simple method to select the most valuable nanobodies from the crowd of positive clones obtained after the initial screening. In this paper, we describe a novel nanobody-based platform that allows comparison of the reactivity of hundreds of clones with the labeled antigen, and identifies the best nanobody pairs for two-site immunoassay development. The output clones are biotinylated in vivo in 96-well culture blocks and then used to saturate the biotin binding capacity of avidin coated wells. This standardizes the amount of captured antibody allowing their sorting by ranking their reactivity with the labeled antigen. Using human soluble epoxide hydrolase (sEH) as a model antigen, we were able to classify 96 clones in four families and confirm this classification by sequencing. This provided a criterion to select a restricted panel of five capturing antibodies and to test each of them against the rest of the 96 clones. The method constitutes a powerful tool for epitope binning, and in our case allowed development of a sandwich ELISA for sEH with a detection limit of 63 pg/mL and four log dynamic range, which performed with excellent recovery in different tissue extracts. This strategy provides a systematic way to test nanobody pairwise combinations and would have a broad utility for the development of highly sensitive sandwich immunoassays.
Assuntos
Ensaio de Imunoadsorção Enzimática , Anticorpos de Domínio Único/imunologia , Anticorpos de Domínio Único/isolamento & purificação , Reações Antígeno-Anticorpo , Antígenos/química , Antígenos/metabolismo , Epóxido Hidrolases/química , Epóxido Hidrolases/metabolismo , Humanos , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , SolubilidadeRESUMO
Recombinant single domain antibodies (nanobodies) constitute an attractive alternative for the production of neutralizing therapeutic agents. Their small size warrants rapid bioavailability and fast penetration to sites of toxin uptake, but also rapid renal clearance, which negatively affects their performance. In this work, we present a new strategy to drastically improve the neutralizing potency of single domain antibodies based on their fusion to a second nanobody specific for the complement receptor CD11b/CD18 (Mac-1). These bispecific antibodies retain a small size (~30 kDa), but acquire effector functions that promote the elimination of the toxin-immunocomplexes. The principle was demonstrated in a mouse model of lethal toxicity with tetanus toxin. Three anti-tetanus toxin nanobodies were selected and characterized in terms of overlapping epitopes and inhibition of toxin binding to neuron gangliosides. Bispecific constructs of the most promising monodomain antibodies were built using anti Mac-1, CD45 and MHC II nanobodies. When co-administered with the toxin, all bispecific antibodies showed higher toxin-neutralizing capacity than the monomeric ones, but only their fusion to the anti-endocytic receptor Mac-1 nanobody allowed the mice to survive a 10-fold lethal dose. In a model of delayed neutralization of the toxin, the anti- Mac-1 bispecific antibodies outperformed a sheep anti-toxin polyclonal IgG that had shown similar neutralization potency in the co-administration experiments. This strategy should have widespread application in the development of nanobody-based neutralizing therapeutics, which can be produced economically and more safely than conventional antisera.
Assuntos
Anticorpos Neutralizantes/imunologia , Antígeno CD11b/imunologia , Antígenos CD18/imunologia , Anticorpos de Domínio Único/imunologia , Antitoxina Tetânica/imunologia , Animais , Afinidade de Anticorpos/imunologia , Sítios de Ligação de Anticorpos/imunologia , Modelos Animais de Doenças , Ensaio de Imunoadsorção Enzimática , Mapeamento de Epitopos , Camundongos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por MatrizRESUMO
The development of immunosensors for the detection of small molecules is of great interest because of their simplicity, high sensitivity and extended analytical range. Due to their size, small compounds cannot be simultaneously recognized by two antibodies impeding their detection by noncompetitive two-site immunoassays, which are superior to competitive ones in terms of sensitivity, kinetics, and working range. In this work, we combine the advantages of magneto-electrochemical immunosensors with the improved sensitivity and direct proportional signal of noncompetitive immunoassays to develop a new Phage Anti-Immunocomplex Electrochemical Immunosensor (PhAIEI) for the detection of the herbicide atrazine. The noncompetitive assay is based on the use of recombinant M13 phage particles bearing a peptide that specifically recognizes the immunocomplex of atrazine with an anti-atrazine monoclonal antibody. The PhAIEI performed with a limit of detection (LOD) of 0.2 pg mL(-1), which is 200-fold better than the LOD obtained using the same antibody in an optimized conventional competitive ELISA, with a large increase in working range. The developed PhAIEI was successfully used to assay undiluted river water samples with no pretreatment and excellent recoveries. Apart from the first demonstration of the benefits of integrating phage anti-immunocomplex particles into electrochemical immunosensors, the extremely low and environmentally relevant detection limits of atrazine attained with the PhAIEIS may have direct applicability to fast and sensitive detection of this herbicide in the environment.
Assuntos
Anticorpos Antivirais/imunologia , Atrazina/análise , Bacteriófago M13/imunologia , Técnicas Biossensoriais/instrumentação , Condutometria/instrumentação , Imunoensaio/instrumentação , Atrazina/imunologia , Eletrodos , Desenho de Equipamento , Análise de Falha de Equipamento , Herbicidas/análise , Herbicidas/imunologia , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
Short peptide loops selected from phage libraries can specifically recognize the formation of hapten-antibody immunocomplexes and can thus be used to develop phage anti-immunocomplex assays (PHAIA) for noncompetitive detection of small molecules. In this study, we generated recombinant chimeras by fusing anti-immunocomplex peptides selected from phage libraries to the N- or C-termini of core streptavidin and used them to setup phage-free noncompetitive assays for the herbicide clomazone (MW 240 Da). The best conditions for refolding were optimized by a high throughput screening allowing to obtain tens of mg of purified protein per liter of culture. The noncompetitive assay developed with these chimeras performed with a 50% saturating concentration (SC50) of 2.2 ± 0.3 ng/mL and limit of detection (LOD) of 0.48 ng/mL. Values that are 13- and 8-fold better that those obtained for the SC50 and LOD of the competitive assay setup with the same antibody. Apart from the first demonstration that recombinant peptide-streptavidin chimeras can be used for sensitive immunodetection of small molecules with a positive readout, this new assay component is a highly standardized reagent with a defined stoichiometry, which can be used in combination with the broad option of existing biotinylated reagents offering a great versatility for the development of conventional immunoassay and biosensors. The utility of the test was demonstrated analyzing the clomazone runoff during the rice growing season in northern Uruguay.
Assuntos
Aptâmeros de Peptídeos/química , Técnicas de Química Analítica/métodos , Herbicidas/química , Imunoensaio , Proteínas Recombinantes/química , Estreptavidina/química , Aptâmeros de Peptídeos/genética , Isoxazóis/química , Limite de Detecção , Oryza/química , Oxazolidinonas/química , Dobramento de Proteína , Proteínas Recombinantes/genéticaRESUMO
Small compounds cannot bind simultaneously to two antibodies, and thus, their immunodetection is limited to competitive formats in which the analyte is indirectly quantitated by measuring the unoccupied antibody binding sites using a competing reporter. This limitation can be circumvented by using phage-borne peptides selected for their ability to specifically react with the analyte-antibody immunocomplex, which allows the detection of these small molecules in a noncompetitive format (PHAIA) with increased sensitivity and a positive readout. In an effort to find substitutes for the phage particles in PHAIA, we explore the use of the B subunit of the Shiga-like toxin of Escherichia coli, also known as verotoxin (VTX), as a scaffold for multivalent display of anti-immunocomplex peptides. Using the herbicides molinate and clomazone as model compounds, we built peptide-VTX recombinant chimeras that were produced in the periplasmic space of E. coli as soluble pentamers, as confirmed by multiangle light scattering analysis. These multivalent constructs, which we termed nanopeptamers, were conjugated to a tracer enzyme and used to detect the herbicide-antibody complex in an ELISA format. The VTX-nanopeptamer assays performed with over a 10-fold increased sensitivity and excellent recovery from spiked surface and mineral water samples. The carbon black-labeled peptide-VTX nanopeptamers showed great potential for the development of a lateral-flow test for small molecules with a visual positive readout that allowed the detection of up to 2.5 ng/mL of clomazone.
Assuntos
Peptídeos/química , Toxina Shiga/química , Escherichia coli Shiga Toxigênica/química , Azepinas/análise , Ensaio de Imunoadsorção Enzimática , Herbicidas/análise , Imunotoxinas/química , Isoxazóis/análise , Mutagênese , Oxazolidinonas/análise , Conformação Proteica , Toxinas Shiga/química , Tiocarbamatos/análise , Proteínas Virais de Fusão/química , Poluentes Químicos da Água/análiseRESUMO
There is a great demand for rapid tests that can be used on-site for the detection of small analytes, such as pesticides, persistent organic pollutants, explosives, toxins, medicinal and abused drugs, hormones, etc. Dipsticks and lateral flow devices, which are simple and provide a visual readout, may be the answer, but the available technology for these compounds requires a competitive format that loses sensitivity and produces readings inversely proportional to the analyte concentration, which is counterintuitive and may lead to potential misinterpretation of the result. In this work, protein-multipeptide constructs composed of anti-immunocomplex peptides selected from phage libraries and streptavidin/avidin as core protein were used for direct detection of small compounds in a noncompetitive two-site immunoassay format that performs with increased sensitivity and positive readout. These constructs that we termed "nanopeptamers" allow the development of rapid point-of-use tests with a positive visual end point of easy interpretation. As proof of concept, lateral flow assays for the herbicides molinate and clomazone were developed and their performance was characterized with field samples.
Assuntos
Azepinas/análise , Isoxazóis/análise , Nanotecnologia , Oxazolidinonas/análise , Tiocarbamatos/análise , Estrutura MolecularRESUMO
Immunosensors for small analytes have been a great addition to the analytical toolbox due to their high sensitivity and extended analytical range. In these systems the analyte is detected when it competes for binding to the detecting antibody with a tracer compound. In this work we introduce the use of phage particles bearing peptides that mimic the target analyte as surrogates for conventional tracers. As a proof of concept, we developed a magneto-electrochemical immunosensor (EI) for the herbicide molinate and compare its performance with conventional formats. Using the same anti-molinate antibody and phage particles bearing a molinate peptidomimetic, the EI performed with an IC(50) of 0.15 ngmL(-1) (linear range from 4.4 × 10(-3) to 10 ngmL(-1)). Compared to the conventional ELISA, the EI was faster (minutes), performed with a much wider linear range, and the detection limit that was 2500-fold lower. The EI produced consistent measurements and could be successfully used to assay river water samples with excellent recoveries. By using the same EI with a conventional tracer, we found that an important contribution to the gain in sensitivity is due to the filamentous structure of the phage (9 × 1000 nm) which works as a multienzymatic tracer, amplifying the competitive reaction. Since phage-borne peptidomimetics can be selected from phage display libraries in a straightforward systematic manner and their production is simple and inexpensive, they can contribute to facilitate the development of ultrasensitive biosensors.
Assuntos
Azepinas/análise , Técnicas Eletroquímicas/métodos , Herbicidas/análise , Imunoensaio/métodos , Biblioteca de Peptídeos , Peptidomiméticos/química , Tiocarbamatos/análise , Anticorpos/imunologia , Azepinas/imunologia , Herbicidas/imunologia , Sensibilidade e Especificidade , Tiocarbamatos/imunologiaRESUMO
Due to their simplicity, speed, low cost, and specificity, immunoassays have become a useful tool for the analysis of environmental pollutants. Once the anti-hapten antibodies are produced, the same hapten or a related molecule is conjugated to a tracer enzyme or coating protein to set up the assay. Here we report the use of peptides that mimic the analyte as advantageous substitutes of competing haptens. These peptides, which open opportunities for innovation in the development of tracer reagents, can be selected from phage display libraries in a straightforward systematic manner. The concept was proven using assays for the herbicides molinate and atrazine as model systems. Several characteristics of the selection process that may affect the final assay were analyzed, such as the phage coat proteins fused to the peptide, the use of linear or constrained peptide libraries, the effect of the concentration of analyte used during the selection process, and the use of monoclonal or polyclonal antibodies as selector molecules. In all cases we found that the selected peptides performed with improved sensitivity as compared with the chemical hapten conventional assays, showing an analogous cross-reactivity pattern. Interestingly, the phage particles perform as robust and highly standardized assay reagents, and due to their filamentous repetitive structure, they function as sensitive multienzymatic reporters.