Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Catheter. cardiovasc. interv ; 93(1): 1-7, Jan. 2019. gráfico, tabela
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024591

RESUMO

BACKGROUND: There is still limited data on the very long term clinical outcomes after ABSORB BRS in daily practice. We sought to evaluate the 3 year-performance of the Absorb bioresorbable vascular scaffolds for the treatment of low/moderate complexity patients enrolled in the ABSORB EXTEND trial. METHODS: ABSORB EXTEND is a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. This study allowed the treatment of lesions ≤28 mm in length and reference vessel diameter of 2.0-3.8 mm (as assessed by on-line QCA). To determine the independent predictors of MACE, a multivariable logistic regression model was built using a stepwise (forward/backward) procedure. RESULTS: Average population age was 61 years and 26.5% had diabetes. Most patients had single target lesion (92.4%). Adequate scaffold deployment (PSP) was achieved in 14.2% of the cases. At three years, the composite endpoints of MACE and ischemia-driven target vessel failure were 9.2% and 10.6%, respectively. The cumulative rate of ARC definite/probable thrombosis was 2.2%, with 1.2% of the cases occurring after the 1st year. Independent predictors of MACE were hypertension and the need for "bail out" stent. CONCLUSION: At three-year follow-up, the use of ABSORB in low/moderate complex PCI was associated with low and acceptable rates of major adverse clinical events, despite the infrequent use of the recommended contemporary scaffold deployment technique. However, scaffold thrombosis rate was higher than reported with current generation of metallic DES. (AU)


Assuntos
Humanos , Trombose , Intervenção Coronária Percutânea , Everolimo
2.
Catheter Cardiovasc Interv ; 93(1): E1-E7, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30286520

RESUMO

BACKGROUND: There is still limited data on the very long term clinical outcomes after ABSORB BRS in daily practice. We sought to evaluate the 3 year-performance of the Absorb bioresorbable vascular scaffolds for the treatment of low/moderate complexity patients enrolled in the ABSORB EXTEND trial. METHODS: ABSORB EXTEND is a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. This study allowed the treatment of lesions ≤28 mm in length and reference vessel diameter of 2.0-3.8 mm (as assessed by on-line QCA). To determine the independent predictors of MACE, a multivariable logistic regression model was built using a stepwise (forward/backward) procedure. RESULTS: Average population age was 61 years and 26.5% had diabetes. Most patients had single target lesion (92.4%). Adequate scaffold deployment (PSP) was achieved in 14.2% of the cases. At three years, the composite endpoints of MACE and ischemia-driven target vessel failure were 9.2% and 10.6%, respectively. The cumulative rate of ARC definite/probable thrombosis was 2.2%, with 1.2% of the cases occurring after the 1st year. Independent predictors of MACE were hypertension and the need for "bail out" stent. CONCLUSION: At three-year follow-up, the use of ABSORB in low/moderate complex PCI was associated with low and acceptable rates of major adverse clinical events, despite the infrequent use of the recommended contemporary scaffold deployment technique. However, scaffold thrombosis rate was higher than reported with current generation of metallic DES. The study is registered on clinicaltrials.gov (unique identifier NCT01023789).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/epidemiologia , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
EuroIntervention ; 12(10): 1255-1262, 2016 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-27866134

RESUMO

AIMS: We sought to compare the outcomes of low/moderate complexity patients treated with the Absorb BVS from the ABSORB EXTEND trial with patients treated with the XIENCE everolimus-eluting stent (EES), using propensity score (PS) matching of pooled data from the SPIRIT trials (SPIRIT II, SPIRIT III, SPIRIT IV) and the XIENCE V USA trial. METHODS AND RESULTS: ABSORB EXTEND was a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. This study allowed the treatment of lesions ≤28 mm in length and with a reference vessel diameter of 2.0-3.8 mm (as assessed by online QCA). The propensity score was obtained by fitting a logistic regression model with the cohort indicator as the binary outcome and other variables as the predictor variables. At one-year clinical follow-up, there was no statistical difference between groups with regard to MACE (5.0% vs. 4.8%, p=0.83), target lesion failure (5.0% vs. 4.7%, p=0.74), ischaemia-driven target vessel revascularisation (2.3% vs. 3.0%, p=0.38) and device thrombosis (1.0% vs. 0.3%, p=0.11). Myocardial infarction was higher with Absorb (3.3% vs. 1.5%, p=0.02), at the expense of periprocedural CK-MB elevation. Independent predictors of MACE among patients receiving Absorb BVS were treatment of multivessel disease, insulin-dependent diabetes and performance of post-dilation. CONCLUSIONS: At one-year follow-up, propensity score-matched analysis demonstrated that the clinical safety and effectiveness of Absorb are comparable to those of XIENCE EES among non-complex patients treated with PCI.


Assuntos
Fármacos Cardiovasculares/uso terapêutico , Stents Farmacológicos , Everolimo/uso terapêutico , Imunossupressores/uso terapêutico , Infarto do Miocárdio/terapia , Implantes Absorvíveis , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/métodos , Fármacos Cardiovasculares/administração & dosagem , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
EuroIntervention ; 12(10): 1255-1262, 2016.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062697

RESUMO

We sought to compare the outcomes of low/moderate complexity patients treated with the Absorb BVS from the ABSORB EXTEND trial with patients treated with the XIENCE everolimus-eluting stent (EES), using propensity score (PS) matching of pooled data from the SPIRIT trials (SPIRIT II, SPIRIT III, SPIRIT IV) and the XIENCE V USA trial...


Assuntos
Serviço Hospitalar de Admissão de Pacientes , Stents
5.
EuroIntervention ; 10(12): 1396-401, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24769555

RESUMO

AIMS: The safety and performance of the Absorb Bioresorbable Vascular Scaffold (Absorb BVS) system (Abbott Vascular, Santa Clara, CA, USA) has been previously established in 131 patients from cohort A and cohort B of the first-in-man ABSORB trial. Following this trial, ABSORB EXTEND was initiated as a global continued access study (outside of the USA) to expand experience with the Absorb BVS system to different geographies with broader inclusion criteria to include the treatment of longer lesions and multiple vessels. We report in this manuscript the twelve-month clinical outcomes of the first 512 patients in this population. METHODS AND RESULTS: ABSORB EXTEND is a prospective, single-arm, open-label clinical study which will enrol up to 800 patients at up to 100 sites. Included are patients with lesions ≤28 mm in length and reference vessel diameter of 2.0-3.8 mm (as assessed by on-line QCA or IVUS). Treatment of a maximum of two de novo native coronary artery lesions is permitted when each lesion is located in a different epicardial vessel. An independent clinical events committee adjudicates all endpoint-related events. At one year, for the first 512 patients enrolled in the study, the composite endpoints of ischaemia-driven MACE and ischaemia-driven target vessel failure were 4.3% and 4.9%, respectively. The cumulative rate of ARC defined definite and probable scaffold thrombosis for this population was 0.8% at one year. CONCLUSIONS: This interim analysis of the ABSORB EXTEND study shows low rates of MACE and scaffold thrombosis. The study is registered on clinicaltrials.gov (unique identifier NCT01023789).


Assuntos
Implantes Absorvíveis , Antineoplásicos/uso terapêutico , Estenose Coronária/terapia , Stents Farmacológicos , Everolimo/uso terapêutico , Intervenção Coronária Percutânea , Alicerces Teciduais , Idoso , Estudos de Coortes , Trombose Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica , Estudos Prospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento
6.
EuroIntervention ; 10(12): 1396-1401, 2015. tab
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062689

RESUMO

Aims: The safety and performance of the Absorb Bioresorbable Vascular Scaffold (Absorb BVS) system(Abbott Vascular, Santa Clara, CA, USA) has been previously established in 131 patients from cohort A andcohort B of the first-in-man ABSORB trial. Following this trial, ABSORB EXTEND was initiated as a globalcontinued access study (outside of the USA) to expand experience with the Absorb BVS system to differentgeographies with broader inclusion criteria to include the treatment of longer lesions and multiple vessels.We report in this manuscript the twelve-month clinical outcomes of the first 512 patients in this population.Methods and results: ABSORB EXTEND is a prospective, single-arm, open-label clinical study whichwill enrol up to 800 patients at up to 100 sites. Included are patients with lesions ≤28 mm in length and referencevessel diameter of 2.0-3.8 mm (as assessed by on-line QCA or IVUS). Treatment of a maximum oftwo de novo native coronary artery lesions is permitted when each lesion is located in a different epicardialvessel. An independent clinical events committee adjudicates all endpoint-related events. At one year, for thefirst 512 patients enrolled in the study, the composite endpoints of ischaemia-driven MACE and ischaemiadriventarget vessel failure were 4.3% and 4.9%, respectively. The cumulative rate of ARC defined definiteand probable scaffold thrombosis for this population was 0.8% at one year.Conclusions: This interim analysis of the ABSORB EXTEND study shows low rates of MACE and scaffoldthrombosis. The study is registered on clinicaltrials.gov (unique identifier NCT01023789).


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Stents Farmacológicos
7.
EuroIntervention ; 9: 1-6, 2013. tab
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062736

RESUMO

Aims: The safety and performance of the Absorb Bioresorbable Vascular Scaffold (Absorb BVS) system(Abbott Vascular, Santa Clara, CA, USA) has been previously established in 131 patients from cohort A andcohort B of the first-in-man ABSORB trial. Following this trial, ABSORB EXTEND was initiated as a globalcontinued access study (outside of the USA) to expand experience with the Absorb BVS system to differentgeographies with broader inclusion criteria to include the treatment of longer lesions and multiple vessels. Wereport in this manuscript the twelve-month clinical outcomes of the first 512 patients in this population.Methods and results: ABSORB EXTEND is a prospective, single-arm, open-label clinical study whichwill enrol up to 800 patients at up to 100 sites. Included are patients with lesions ≤28 mm in length and referencevessel diameter of 2.0-3.8 mm (as assessed by on-line QCA or IVUS). Treatment of a maximum of twode novo native coronary artery lesions is permitted when each lesion is located in a different epicardial vessel.An independent clinical events committee adjudicates all endpoint-related events. At one year, for the first512 patients enrolled in the study, the composite endpoints of ischaemia-driven MACE and ischaemia-driventarget vessel failure were 4.3% and 4.9%, respectively. The cumulative rate of ARC defined definite andprobable scaffold thrombosis for this population was 0.8% at one year.Conclusions: This interim analysis of the ABSORB EXTEND study shows low rates of MACE and scaffoldthrombosis. The study is registered on clinicaltrials.gov (unique identifier NCT01023789).


Assuntos
Infarto do Miocárdio , Stents , Traumatismos Cardíacos
8.
Rev. bras. cardiol. invasiva ; 20(3): 239-246, 2012. tab
Artigo em Português | LILACS, Sec. Est. Saúde SP | ID: lil-656086

RESUMO

INTRODUÇÃO: Os estudos com stents farmacológicos têm avaliado predominantemente populações masculinas de descendência europeia. O estudo de braço único SPIRIT Women avalia o stent eluidor de everolimus XIENCE TM V em lesões de novo complexas em uma população feminina do mundo real, incluindo pacientes latino-americanas. Esta análise permite compreender como essa população responde ao implante de stent, comparativamente a pacientes não-latino-americanas. MÉTODOS: Das 1.572 pacientes matriculadas em 73 locais fora dos Estados Unidos, 138 (9%) foram recrutadas na Argentina, no Brasil e na Venezuela. RESULTADOS: As lesões-alvo tinham diâmetro de referência do vaso entre 2,25 mm e 4 mm e extensão da lesão ≤ 28 mm. As características basais foram semelhantes entre os grupos, com exceção de maior prevalência de hipertensão arterial, infarto do miocárdio (IM) de parede anterior e história familiar de doença arterial coronária na coorte latino-americana. As lesões tendiam a ser mais complexas em mulheres latino-americanas, com menor diâmetro de referência do vaso-alvo, maior extensão da lesão, maior excentricidade e angulação e mais lesões tipo B2/C. Os eventos foram adjudicados de acordo com as definições do Academic Research Consortium. Em um ano, o desfecho combinado de morte por todas as causas, IM e revascularização do vaso-alvo (RVA) foi de 12,1% na população não-latino-americana e de 10,1% na população latino-americana (P = 0,58). CONCLUSÕES: Em um ano, os baixos índices de eventos cardíacos adversos, incluindo trombose do stent, falha da lesão-alvo, morte cardíaca, IM e RVA nas mulheres latino-americanas foram comparáveis aos das mulheres não-latino-americanas, apesar da maior complexidade das lesões. Esses resultados demonstram a segurança e a eficácia do stent XIENCE TM V nessa pequena coorte de pacientes latino-americanas, à semelhança do que é observado com populações maiores e mais variadas.


BACKGROUND: Drug-eluting stent trials have predominantly examined male populations of European descent. SPIRIT Women single-arm study evaluates the XIENCE TM V everolimus-eluting stent in complex de novo lesions in a real world female population, including Latin American patients. This analysis provides an insight into how this population responds to stenting when compared to non-Latin American patients. METHODS: Of the 1,572 patients enrolled from 73 non-US sites, 138 (9%) were recruited from Argentina, Brazil and Venezuela. RESULTS: Target lesions had reference vessel diameter ranging between 2.25 mm and 4 mm and lesion length ≤ 28 mm. Baseline characteristics were similar between the groups, with exception to a higher prevalence of hypertension, anterior myocardial infarction (MI) and family history of coronary artery disease in the Latin American cohort. Lesions tended to be more complex in Latin American women with a smaller reference vessel diameter, longer lesion length, increased eccentricity and angulation, and more type B2/C lesions. Events were adjudicated according to the guidelines of the Academic Research Consortium. At 1 year, the composite endpoint of death, MI and target vessel revascularization (TVR) was 12.1% in the non-Latin American population and 10.1% in the Latin American population (P = 0.58). CONCLUSIONS: At 1 year, the low rates of adverse cardiac events, including stent thrombosis, target lesion failure, cardiac death, MI and TVR in Latin American women were comparable to those of the non-Latin American women, despite the higher complexity of lesions. These results demonstrate the safety and efficacy of the XIENCE TM V stent in this small cohort of Latin American patients, in line with what is observed in larger and more varied populations.


Assuntos
Humanos , Feminino , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Stents Farmacológicos , Causalidade , Estudos Prospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA