Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
Eur J Dent ; 18(3): 950-956, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38744324

RESUMO

This case report addresses the treatment of excessive gingival display (EGD) in the context of maxillary asymmetry, zenith irregularities, and occlusal plane inclination. Digital planning was pivotal in formulating a precise treatment strategy by incorporating facial photographs, digital models, and cone-beam computed tomography data. Parameters, including occlusal plane inclination, teeth position, and lip-to-gingival margin relationships, were considered to ensure treatment alignment with the patient's facial characteristics. Notably, during the planning phase, it was evident that the conventional approach using the cementoenamel junction as the apical limit for incisions would result in asymmetry. Consequently, the gingival margin position was defined in accordance with facial and lip features. The chosen treatment, flapless crown lengthening, was tailored to the patient's thin phenotype and guided by measurements derived from digital planning. Postsurgery, the patient experienced a swift and painless recovery. A harmonious smile with a stable gingival margin position was achieved at the 1-year follow-up, seamlessly complementing the patient's facial attributes. This case underscores the importance of personalized EGD treatment and the value of digital planning in enhancing diagnostic accuracy and precise treatment planning, ultimately facilitating optimal treatment strategies.

2.
Dentomaxillofac Radiol ; 53(4): 207-221, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38429951

RESUMO

OBJECTIVES: The aim of this systematic review was to verify the accuracy of linear measurements performed on low-dose CBCT protocols for implant planning, in comparison with those performed on standard and high-resolution CBCT protocols. METHODS: The literature search included four databases (Pubmed, Web of Science, Embase, and Scopus). Two reviewers independently screened titles/abstracts and full texts according to eligibility criteria, extracted the data, and examined the methodological quality. Risk of bias assessment was performed using the Quality Assessment Tool For In Vitro Studies. Random-effects meta-analysis was used for pooling measurement error data. RESULTS: The initial search yielded 4684 titles. In total, 13 studies were included in the systematic review, representing a total of 81 samples, while 9 studies were included in the meta-analysis. The risk of bias ranged from medium to low. The main results across the studies indicate a strong consistency in linear measurements performed on low-dose images in relation to the reference methods. The overall pooled planning measurement error from low-dose CBCT protocols was -0.24 mm (95% CI, -0.52 to 0.04) with a high level of heterogeneity, showing a tendency for underestimation of real values. Various studies found no significant differences in measurements across different protocols (eg, voxel sizes, mA settings, or dose levels), regions (incisor, premolar, molar) and types (height vs. width). Some studies, however, noted exceptions in measurements performed on the posterior mandible. CONCLUSION: Low-dose CBCT protocols offer adequate precision and accuracy of linear measurements for implant planning. Nevertheless, diagnostic image quality needs must be taken into consideration when choosing a low-dose CBCT protocol.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Planejamento de Assistência ao Paciente , Doses de Radiação , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Implantação Dentária Endóssea/métodos , Implantes Dentários
3.
Braz Oral Res ; 37: e099, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38055517

RESUMO

This study aimed to investigate whether two acquisition parameters, voxel size and filter thickness, used in a micro-computed tomography (micro-CT) scan, together with the examiner's experience, influence the outcome of bone repair analysis in an experimental model. Bone defects were created in rat tibiae and scanned using two voxel sizes of 6- or 12-µm and two aluminum filter thickness of 0.5- or 1-mm. Then, bone volume fraction (BV/TV) and trabecular thickness (Tb.Th) were analyzed twice by two groups of operators: experienced and inexperienced examiners. For BV/TV, no significant differences were found between scanning voxel sizes of 6 and 12 µm for the experienced examiners; however, for the inexperienced examiners, the analysis performed using a 12-µm voxel size resulted in higher BV/TV values (32.4 and 32.9) than those acquired using a 6-µm voxel size (25.4 and 24.8) (p < 0.05). For Tb.Th, no significant differences between the analyses performed by experienced and inexperienced groups were observed when using the 6-µm voxel size. However, inexperienced examiners' analysis revealed higher Tb.Th values when using the 12-µm voxel size compared with 6 µm (0.05 vs. 0.03, p < 0.05). Filter thickness had no influence on the results of any group. In conclusion, voxel size and operator experience affected the measured Tb.Th and BV/TV of a region with new bone formation. Operator experience in micro-CT analysis is more critical for BV/TV than for Tb.Th, whereas voxel size significantly affects Tb.Th evaluation. Operators in the initial phases of research training should be calibrated for bone assessments.


Assuntos
Osso e Ossos , Tíbia , Animais , Ratos , Microtomografia por Raio-X , Tíbia/diagnóstico por imagem , Densidade Óssea
4.
Braz Dent J ; 34(5): 43-52, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38133472

RESUMO

This study evaluated the influence of a fluoride-modified titanium surface on osseointegration in rats with induced diabetes. One hundred and eighty rats were randomly allocated into 3 groups with 60 animals each: Control group (C): Animals without diabetes; Diabetes Group (D): Animals with uncontrolled induced diabetes; Controlled Diabetes Group (CD): Animals with diabetes induced controlled by the insulin administration. Diabetes was induced by streptozotocin injection. Each animal received 2 implants in the proximal tibial metaphysis, one with the machined surface (M) and the other one with a fluoride-modified titanium surface (F), after 4 weeks of induction of diabetes. The animals were submitted to euthanasia 2, 4, and 6 weeks after the implant placement (n = 20 animals/group). The osseointegration was evaluated by the implant removal torque test and the histometric analysis of the non-decalcified histological sections: 1) Contact bone/implant (%BIC); 2) Bone tissue area between implant threads (%BBT). Implants with F surface showed a higher removal torque than implants with surface M in all groups. There was no difference in %BIC between the groups regardless of the surface used. The F surface showed a tendency to present higher %BBT values for the 3 evaluation periods in the D group. The fluoride-modified implant surface has no impact on the %BIC and %BBT. However, the fluoride-modified implant surface increases the locking of the implants with the bone. The hyperglycemia was associated with lower removal torque values despite the surfaces of the implant used.


Assuntos
Implantes Dentários , Diabetes Mellitus , Ratos , Animais , Osseointegração , Fluoretos , Tíbia , Titânio , Propriedades de Superfície , Torque
5.
Braz. dent. j ; Braz. dent. j;34(5): 43-52, Sept.-Oct. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1528014

RESUMO

Abstract This study evaluated the influence of a fluoride-modified titanium surface on osseointegration in rats with induced diabetes. One hundred and eighty rats were randomly allocated into 3 groups with 60 animals each: Control group (C): Animals without diabetes; Diabetes Group (D): Animals with uncontrolled induced diabetes; Controlled Diabetes Group (CD): Animals with diabetes induced controlled by the insulin administration. Diabetes was induced by streptozotocin injection. Each animal received 2 implants in the proximal tibial metaphysis, one with the machined surface (M) and the other one with a fluoride-modified titanium surface (F), after 4 weeks of induction of diabetes. The animals were submitted to euthanasia 2, 4, and 6 weeks after the implant placement (n = 20 animals/group). The osseointegration was evaluated by the implant removal torque test and the histometric analysis of the non-decalcified histological sections: 1) Contact bone/implant (%BIC); 2) Bone tissue area between implant threads (%BBT). Implants with F surface showed a higher removal torque than implants with surface M in all groups. There was no difference in %BIC between the groups regardless of the surface used. The F surface showed a tendency to present higher %BBT values for the 3 evaluation periods in the D group. The fluoride-modified implant surface has no impact on the %BIC and %BBT. However, the fluoride-modified implant surface increases the locking of the implants with the bone. The hyperglycemia was associated with lower removal torque values despite the surfaces of the implant used.


Resumo Este estudo avaliou a influência de uma superfície de titânio modificada com flúor na osseointegração em ratos com diabetes induzida. Cento e oitenta ratos foram distribuídos aleatoriamente em 3 grupos com 60 animais cada: Grupo controle (C): Animais sem diabetes; Grupo Diabetes (D): Animais com diabetes induzida descompensada; Grupo Diabetes Controlado (CD): Animais com diabetes induzido controlado pela administração de insulina. O diabetes foi induzido por injeção de estreptozotocina. Cada animal recebeu 2 implantes na metáfise proximal da tíbia, um com superfície usinada (M) e outro com superfície de titânio modificado com flúor (F), após 4 semanas de indução do diabetes. Os animais foram submetidos à eutanásia 2, 4 e 6 semanas após a colocação do implante (n = 20 animais/grupo). A osseointegração foi avaliada pelo teste de torque de remoção do implante e pela análise histométrica dos cortes histológicos não descalcificados: 1) Contato osso-implante (%BIC); 2) Área de tecido ósseo entre as roscas do implante (%BBT). Os implantes com superfície F apresentaram maior torque de remoção do que os implantes com superfície M em todos os grupos. Não houve diferença no %BIC entre os grupos independente da superfície utilizada. A superfície F mostrou tendência a apresentar maiores valores de %BBT para os 3 períodos de avaliação no grupo D. As superfícies de implantes modificadas com flúor não influenciaram nos dados de %BIC e %BBT. Entretanto, essas superfícies aumentaram o travamento dos implantes no tecido ósseo. A hiperglicemia foi associada a menores torques de remoção dos implantes independentemente do tipo de superfície de implante utilizada.

6.
Clin Oral Implants Res ; 34(6): 543-554, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36939434

RESUMO

OBJECTIVE: The aim of this study was to systematically analyze the influence of smoking on the incidence of peri-implantitis. MATERIALS AND METHODS: The search was performed in the National Library of Medicine (MEDLINE-PubMed), SCOPUS, EMBASE, and ISI Web of Science databases (finished on November 30, 2022). Systematic review and meta-analysis were conducted according to PRISMA statement. Prospective cohort studies that evaluate the incidence of peri-implantitis in smokers and non-smokers were included. Two authors independently searched for eligible studies, screened titles, and abstracts, did the full-text analysis, extracted data, and performed the risk-of-bias assessment. The results were summarized through random-effects meta-analyses. The GRADE method was used to determine the certainty of evidence. RESULTS: A total of 7 studies with 702 patients and 1959 implants were included for analysis. The meta-analysis revealed a significant difference between smokers and non-smokers for the risk of peri-implantitis in the implant-based (p < .0001) and patient-based analysis (p = .003). A strong association between smoking and the risk for peri-implantitis was verified at the implant level (RR: 2.04, 95% CI: 1.46-1.85) and the patient level (RR: 2.79, 95% CI: 1.42-5.50). CONCLUSIONS: Moderate certainty evidence suggests that smoking is associated with peri-implantitis compared to non-smoking at the patient and implant levels.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Peri-Implantite/epidemiologia , Peri-Implantite/etiologia , Implantes Dentários/efeitos adversos , Incidência , Estudos Prospectivos , Bases de Dados Factuais
7.
Artigo em Inglês | MEDLINE | ID: mdl-36674057

RESUMO

The aim of this study was two-fold: (1) to describe the surveillance and biosafety measures adopted by dentists, dental hygienists, and dental assistants who worked in the Southern Region of Brazil and (2) to evaluate access to information in the context of the COVID-19 pandemic. This was a multicenter and cross-sectional design, using a self-applied and validated online questionnaire. The availability of health-care-related supplies and the adoption of biosafety measures recommended by the Technical Note of the National Health Surveillance Agency No. 04/2020 were analyzed. A total of 2560 Brazilian workers participated (75.8% dentists, 15.7% dental assistants and 8.5% dental hygienists), 52.7% from the public and 37.7% from the private sector. Approximately 70% of the individuals reported being away from work during the pandemic. The surveillance measures adopted with higher mean scores were the investigation of respiratory infection symptoms when scheduling appointments and the adoption of distancing in the waiting room. Of the biosafety measures to avoid aerosols, the procedures with lower compliance were those related to the use of intraoral radiographs and rubber dams. Moreover, the correct use of personal protective equipment at work seems to be related to self-perceived stress and anxiety. Worryingly, high access to information through non-governmental documents was observed. Permanent health education policies should reinforce safe practices and encourage workers to implement biosafety and surveillance measures in health services.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias , Brasil/epidemiologia , SARS-CoV-2 , Mão de Obra em Saúde , Estudos Transversais , Odontólogos , Aerossóis e Gotículas Respiratórios , Inquéritos e Questionários
8.
J Digit Imaging ; 36(3): 1158-1179, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36604364

RESUMO

Using computer vision through artificial intelligence (AI) is one of the main technological advances in dentistry. However, the existing literature on the practical application of AI for detecting cephalometric landmarks of orthodontic interest in digital images is heterogeneous, and there is no consensus regarding accuracy and precision. Thus, this review evaluated the use of artificial intelligence for detecting cephalometric landmarks in digital imaging examinations and compared it to manual annotation of landmarks. An electronic search was performed in nine databases to find studies that analyzed the detection of cephalometric landmarks in digital imaging examinations with AI and manual landmarking. Two reviewers selected the studies, extracted the data, and assessed the risk of bias using QUADAS-2. Random-effects meta-analyses determined the agreement and precision of AI compared to manual detection at a 95% confidence interval. The electronic search located 7410 studies, of which 40 were included. Only three studies presented a low risk of bias for all domains evaluated. The meta-analysis showed AI agreement rates of 79% (95% CI: 76-82%, I2 = 99%) and 90% (95% CI: 87-92%, I2 = 99%) for the thresholds of 2 and 3 mm, respectively, with a mean divergence of 2.05 (95% CI: 1.41-2.69, I2 = 10%) compared to manual landmarking. The menton cephalometric landmark showed the lowest divergence between both methods (SMD, 1.17; 95% CI, 0.82; 1.53; I2 = 0%). Based on very low certainty of evidence, the application of AI was promising for automatically detecting cephalometric landmarks, but further studies should focus on testing its strength and validity in different samples.


Assuntos
Algoritmos , Inteligência Artificial , Humanos , Reprodutibilidade dos Testes , Cefalometria/métodos , Processamento Eletrônico de Dados
9.
J Digit Imaging ; 36(1): 356-364, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36070014

RESUMO

The objective of this study was to evaluate the influence of the extraction socket (distal or lingual root) and the type of region of interest (ROI) definition (manual or predefined) on the assessment of alveolar repair following tooth extraction using micro-computed tomography (micro-CT). The software package used for scanning, reconstruction, reorientation, and analysis of images (NRecon®, DataViewer®, CT-Analyzer®) was acquired through Bruker < https://www.bruker.com > . The sample comprised the micro-CT volumes of seven Wistar rat mandibles, in which the right first molar was extracted. The reconstructed images were analyzed using the extraction sockets, i.e., the distal and intermediate lingual root and the method of ROI definition: manual (MA), central round (CR), and peripheral round (PR). The bone volume fraction (BV/TV) values obtained were analyzed by two-way ANOVA with Tukey's post hoc test (α = 5%). The distal extraction socket resulted in significantly lower BV/TV values than the intermediate lingual socket for MA (P = 0.001), CR (P < 0.001), and PR (P < 0.001). Regarding the ROI, when evaluating the distal extraction socket, the BV/TV was significantly higher (P < 0.001) for MA than for CR and PR, with a lower BV/TV for CR. However, no significant difference was observed for MA (P = 0.855), CR (P = 0.769), or PR (P = 0.453) in the intermediate lingual extraction socket. The bone neoformation outcome (BV/TV) for alveolar bone repair after tooth extraction is significantly influenced by the ROI and the extraction socket. Using the predefined method with a standardized ROI in the central region of the distal extraction socket resulted in the assessment of bone volume, demonstrating the most critical region of the bone neoformation process.


Assuntos
Extração Dentária , Alvéolo Dental , Animais , Ratos , Alvéolo Dental/cirurgia , Microtomografia por Raio-X , Ratos Wistar , Extração Dentária/métodos , Análise de Variância
10.
Braz. oral res. (Online) ; 37: e099, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520522

RESUMO

Abstract This study aimed to investigate whether two acquisition parameters, voxel size and filter thickness, used in a micro-computed tomography (micro-CT) scan, together with the examiner's experience, influence the outcome of bone repair analysis in an experimental model. Bone defects were created in rat tibiae and scanned using two voxel sizes of 6- or 12-µm and two aluminum filter thickness of 0.5- or 1-mm. Then, bone volume fraction (BV/TV) and trabecular thickness (Tb.Th) were analyzed twice by two groups of operators: experienced and inexperienced examiners. For BV/TV, no significant differences were found between scanning voxel sizes of 6 and 12 µm for the experienced examiners; however, for the inexperienced examiners, the analysis performed using a 12-µm voxel size resulted in higher BV/TV values (32.4 and 32.9) than those acquired using a 6-µm voxel size (25.4 and 24.8) (p < 0.05). For Tb.Th, no significant differences between the analyses performed by experienced and inexperienced groups were observed when using the 6-µm voxel size. However, inexperienced examiners' analysis revealed higher Tb.Th values when using the 12-µm voxel size compared with 6 µm (0.05 vs. 0.03, p < 0.05). Filter thickness had no influence on the results of any group. In conclusion, voxel size and operator experience affected the measured Tb.Th and BV/TV of a region with new bone formation. Operator experience in micro-CT analysis is more critical for BV/TV than for Tb.Th, whereas voxel size significantly affects Tb.Th evaluation. Operators in the initial phases of research training should be calibrated for bone assessments.

11.
Braz Dent J ; 33(4): 40-46, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36043567

RESUMO

The study aimed to evaluate the accuracy of Micro-CT in linear and volumetric measurements in native (NB) and grafted bone (GB) areas. A total of 111 biopsies of maxillary sinuses grafted with deproteinized bovine bone (DBB) in humans were evaluated. The linear measurements were performed to measure the length of the NB and GB. Furthermore, the amount of mineralized tissues at the NB and GB was performed. In the histomorphometry analysis the percentage of mineralized tissues at the NB and GB was obtained in two histological sections while the mineralized tissues were measure in the micro-CT varying the thresholds of the grayscale varying from 90-250 to 90-150 with 10 levels of variation between each one was applied. Then these data were correlated in order to check the higher r level between the histomorphometry and micro-CT thresholds intervals. The linear length of the NB was 2.44±0.91mm and 2.48±1.50mm, respectively, for micro-CT and histomorphometry (r =0.57), while the linear length of the GB was 3.63±1.66mm and 3.13±1.45mm, respectively, for micro-CT and histomorphometry (r =0.74) Histomorphometry showed 45.91±11.69% of bone in NB, and 49.57±5.59% of bone and biomaterial in the GB. The total volume of mineralized tissues that were closest to the histometric analysis were 43.75±15.39% in the NB (Threshold:90-240; r = 0.50) and 51.68±8.42% in the GB (Threshold:90-180; r =-0.028). The micro-CT analysis showed good accuracy in the linear analysis in both portions of the biopsies but for volumetric analysis just in NB.


Assuntos
Substitutos Ósseos , Osso e Ossos , Animais , Materiais Biocompatíveis , Bovinos , Humanos , Seio Maxilar , Microtomografia por Raio-X
12.
Braz. dent. j ; Braz. dent. j;33(4): 40-46, July-Aug. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1394093

RESUMO

Abstract The study aimed to evaluate the accuracy of Micro-CT in linear and volumetric measurements in native (NB) and grafted bone (GB) areas. A total of 111 biopsies of maxillary sinuses grafted with deproteinized bovine bone (DBB) in humans were evaluated. The linear measurements were performed to measure the length of the NB and GB. Furthermore, the amount of mineralized tissues at the NB and GB was performed. In the histomorphometry analysis the percentage of mineralized tissues at the NB and GB was obtained in two histological sections while the mineralized tissues were measure in the micro-CT varying the thresholds of the grayscale varying from 90-250 to 90-150 with 10 levels of variation between each one was applied. Then these data were correlated in order to check the higher r level between the histomorphometry and micro-CT thresholds intervals. The linear length of the NB was 2.44±0.91mm and 2.48±1.50mm, respectively, for micro-CT and histomorphometry (r =0.57), while the linear length of the GB was 3.63±1.66mm and 3.13±1.45mm, respectively, for micro-CT and histomorphometry (r =0.74) Histomorphometry showed 45.91±11.69% of bone in NB, and 49.57±5.59% of bone and biomaterial in the GB. The total volume of mineralized tissues that were closest to the histometric analysis were 43.75±15.39% in the NB (Threshold:90-240; r = 0.50) and 51.68±8.42% in the GB (Threshold:90-180; r =-0.028). The micro-CT analysis showed good accuracy in the linear analysis in both portions of the biopsies but for volumetric analysis just in NB.


Resumo Esse estudo tem como objetivo avaliar a acurácia da análise microtomográfica em mensurações lineares e volumétricas em osso nativo (ON) e enxertado (OE). Para isso, 111 biópsias removidas de seios maxilares de pacientes enxertados com osso bovino desproteinizado foram coletadas e avaliadas. As medidas lineares foram realizadas para medir o comprimento do ON e do OE. Além disso, foi realizada a mensuração da quantidade de tecidos mineralizados em ON e OE. Na análise histomorfométrica a porcentagem de tecidos mineralizados do ON e OE foi obtida em dois cortes histológicos enquanto os tecidos mineralizados foram medidos em microtomografias variando os thresholds da escala de cinza variando de 90-250 a 90-150 com 10 níveis de variação entre cada. Em seguida, esses dados foram correlacionados para verificar o maior nível de R entre os intervalos dos thresholds testados na análise microtomográfica em relação aos dados obtidos na histomorfometria. O comprimento linear do ON foi de 2,44±0,91mm e 2,48±1,50mm, respectivamente, para análises microtomográfica e histomorfométrica (r=0,57), enquanto o comprimento linear do OE foi de 3,63±1,66mm e 3,13±1,45mm, respectivamente, para para análises microtomográfica e histomorfométrica (r =0,74) A histomorfometria detectou 45,91±11,69% de osso na porção de ON e 49,57±5,59% de osso e biomaterial na porção de OE. O volume total de tecidos mineralizados detectados pela análise microtomográfica que apresentou valores mais próximos da análise histomorfométrica foi de 43,75±15,39% no ON (Thresholds:90-240; r = 0,50) e 51,68±8,42% no OE (Thresholds:90-180; r =- 0,028). A análise microtomográfica apresentou boa acurácia na análise linear em ambas as porções das biópsias, porém a mesma apresentou boa acurácia para análise volumétrica apenas em áreas de ON.

13.
BMC Oral Health ; 22(1): 233, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35698117

RESUMO

BACKGROUND: Implant installation with conventional drilling can create buccal bone defects in areas of limited ridge thickness. Implant installation with osseodensification may aid in preventing buccal bone defects in these situations. This in vitro pilot study evaluated the impact of osseodensification on the increase in alveolar ridge thickness and the prevention of buccal peri-implant defects. METHODS: Ten fresh pig mandibles with limited bone thickness were selected for use in an experimental randomized split mouth pilot study. Two site-preparation protocols were used: conventional drilling with cutting burs (CTL, n = 10) and osseodensification with Densah® burs (OD, n = 10). After implant bed preparation, 20 implants (4.5 × 10 mm) were placed in the prepared sites and the insertion torque was recorded. Clinical and photographic analysis evaluated ridge thickness and the extent (height, width, and area) of bone defects in the buccal and lingual bone walls following implant placement. Three-dimensional measurements were performed using STL files to analyze the increase in buccal ridge thickness following site preparation and implant placement. The height of the buccal bone defect was considered as the primary outcome of this study. Defect width, area, implant insertion torque, and linear buccal ridge increase after implant site preparation and installation were also assessed. Non-parametric evaluations were carried out with the Mann-Whitney test to verify intergroup differences. RESULTS: There was no statistically significant difference between groups in the baseline ridge thickness. OD presented a significantly higher insertion torque, associated with reduced buccal and lingual bone defect width, in comparison to CTL. CONCLUSIONS: The increase in buccal ridge thickness after site preparation and implant placement was significantly higher in OD compared to CTL. Osseodensification increased the ridge thickness through expansion and reduced buccal bone defects after implant installation.


Assuntos
Aumento do Rebordo Alveolar , Implantes Dentários , Processo Alveolar/cirurgia , Aumento do Rebordo Alveolar/métodos , Animais , Implantação Dentária Endóssea/métodos , Humanos , Boca , Projetos Piloto , Suínos
14.
Sci Rep ; 12(1): 1424, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-35082347

RESUMO

Despite the current advances in micro-CT analysis, the influence of some image acquisition parameters on the morphometric assessment outcome have not been fully elucidated. The aim of this study was to determine whether data binning and frame averaging affect the morphometric outcome of bone repair assessment using micro-CT. Four Wistar rats' tibiae with a surgically created bone defect were imaged with micro-CT six times each, frame averaging set to 1 and 2, and data binning set to 1, 2 and 4, for each of the averaging values. Two-way ANOVA followed by Bonferroni tests assessed the significance of frame averaging and data binning on a set of morphometric parameters assessed in the image volumes (p < 0.01). The effect of frame averaging was not significant for any of the assessed parameters. Increased data binning led to larger trabecular thickness. In contrast, smaller bone volume fraction and bone volume were found as data binning increased. Trabeculae number and trabecular separation were not influenced by any of the parameters. In conclusion, the morphometric outcome of bone repair assessment in micro-CT demonstrated dependency upon data binning, but not frame averaging. Therefore, image acquisition of small anatomical structures (e.g., rat trabeculae) should be performed without data binning.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/normas , Tíbia/diagnóstico por imagem , Microtomografia por Raio-X/normas , Animais , Regeneração Óssea/fisiologia , Masculino , Ratos , Ratos Wistar , Tíbia/lesões
15.
Rev. odontol. UNESP (Online) ; 51: e20220045, 2022. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1424231

RESUMO

Introdução: o desafio no uso do Micro-Ct tem sido estabelecer e padronizar padrões adequados para escaneamento e tratamento das imagens, para que se obtenha o máximo desempenho do equipamento, e permitir a comparação dos achados entre diferentes estudos. Objetivo: o presente estudo tem como objetivo comparar a porcentagem de volume ósseo em regiões com perda óssea periodontal utilizando diferentes metodologias para definição da área a ser analisada (ROI). Material e método: dez ratos foram submetidos à indução de doença periodontal, e, após a eutanásia, as mandíbulas foram escaneadas com cortes de 9 µ e 18 µm de espessura, com passo de rotação de 0.3mm. As imagens foram reconstituídas utilizando o software NRecon, e em seguida, utilizando o software CTAnalyser - CTAn, foram definidas as áreas de interesse (ROI) ao redor dos segundos molares. A primeira área de interesse (ROI1) foi definida em um padrão retangular que se restringiu às regiões interproximais e furca, onde a área total de tecido ósseo foi obtida somando os resultados dos 3 ROIs. A segunda área (ROI2) foi definida no sentido corono/apical ao redor do segundo molar até suas limitações proximais com os dentes vizinhos, onde a porcentagem de tecido ósseo pertencente às raízes foram excluídas das avaliações. As análises foram realizadas com cinco diferentes valores de thresholds (130-50, 130-60, 130-70, 130-80, 130-90 e 130-100). Resultado: a análise entre os diferentes ROIs demonstrou que em ambas as análises foi observada a tendência a menor porcentagem de tecido ósseo quanto maior o contraste de tons de cinza utilizado, no entanto, nos resultados obtidos no ROI2 essa diferença não foi estatisticamente significante. Conclusão: com os resultados obtidos pode se concluir que a utilização de diferentes thresholds para quantificação óssea, em áreas onde houve doença periodontal, pode trazer resultados divergentes; a definição da área de interesse interfere com os resultados obtidos e que a obtenção de uma área de interesse com a remoção das raízes mostrou-se menos susceptível à variação dos parâmetros de escaneamento.


Introduction: the challenge in the use of Micro-Ct has been to establish and standardize adequate standards for scanning and image processing to obtain the maximum performance of the equipment and to allow the comparison of findings between different studies. Objective: this study aims to compare the percentage of bone volume in regions with periodontal bone loss using different methodologies to define the area to be analysed (ROI). Material and method: ten rats were submitted to periodontal disease induction, and, after euthanasia, the mandibles were scanned with slices of 9µ and 18 µm thickness, with a rotation step of 0.3mm. The images were reconstructed using the NRecon software, and then, using the CTAnalyser - CTAn software, the areas of interest (ROI) around the second molars were defined. The first area of interest (ROI1) was defined in a rectangular pattern that was restricted to the interproximal and furcation regions, where the total area of bone tissue was obtained by adding the results of the 3 ROIs. The second area (ROI2) was defined in the coronal/apical direction around the second molar to its proximal limitations with the neighboring teeth, in which the percentage of bone tissue belonging to the roots was excluded from the evaluations. Analyses were performed with five different threshold values (130-50, 130-60, 130-70, 130-80, 130-90, and 130-100). Result: the analysis between the different ROIs showed that, in both analyses, there was a tendency towards a lower percentage of bone tissue the greater the grayscale contrast used. However, in the results obtained in ROI2, this difference was not statistically significant. Conclusion: with the results obtained, it can be concluded that the use of different thresholds for bone quantification, in areas where there was a periodontal disease, can bring divergent results; the definition of the area of ​​interest interferes with the results obtained; and that obtaining an area of interest with the removal of the roots, proved to be less susceptible to the variation of the scanning parameters.


Assuntos
Animais , Ratos , Doenças Periodontais , Periodontite , Perda do Osso Alveolar , Microtomografia por Raio-X , Mandíbula , Dente Molar , Análise de Variância
16.
Braz Dent J ; 32(1): 9-15, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33914008

RESUMO

Aiming to evaluate cortical bone microarchitecture and osteonal morphology after irradiation, twelve male New Zealand rabbits were used. The animals were divided: control group (no radiation-NIr); and 3 irradiated groups, sacrificed after: 7 (Ir7d); 14 (Ir14d) and 21 (Ir21d) days. A single radiation dose of 30 Gy was used. Computed microtomography analyzed the cortical microarchitecture: cortical thickness (CtTh), bone volume (BV), total porosity (Ct.Po), intracortical porosity (CtPo-cl), channel/pore number (Po.N), fractal dimension (FD) and degree of anisotropy (Ct.DA). After scan, osteonal morphology was histologically assessed by means: area and perimeter of the osteons (O.Ar; O.p) and of the Haversian canals (C.Ar; C.p). Microtomographic analysis were performed by ANOVA, followed by Tukey and Dunnet tests. Osteon morphology analyses were performed by Kruskal-Wallis, and test Dunn's. Cortical thickness was significant difference (p<0.010) between the NIr and irradiated groups, with thicker cortex at Ir7d (1.15±0.09). The intracortical porosity revealed significant difference (p<0.001) between irradiated groups and NIr, with lower value for Ir7d (0.29±0.09). Bone volume was lower in Ir14d compared to control. Area and perimeter of the osteons were statistically different (p<0.0001) between NIr and Ir7d. Haversian canals also revealed lower values (p<0.0001) in Ir7d (80.57±9.3; 31.63±6.5) compared to NIr and irradiated groups. Cortical microarchitecture was affected by radiation, and the effects appear to be time-dependent, mostly regarding the osteons morphology at the initial days. Cortex structure in Ir21d revealed similarities to control suggesting that microarchitecture resembles normal condition after a period.


Assuntos
Osso Cortical , Ósteon , Animais , Osso e Ossos , Osso Cortical/diagnóstico por imagem , Fractais , Masculino , Porosidade , Coelhos
17.
Braz. dent. j ; Braz. dent. j;32(1): 9-15, Jan.-Feb. 2021. graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1180725

RESUMO

Abstract Aiming to evaluate cortical bone microarchitecture and osteonal morphology after irradiation, twelve male New Zealand rabbits were used. The animals were divided: control group (no radiation-NIr); and 3 irradiated groups, sacrificed after: 7 (Ir7d); 14 (Ir14d) and 21 (Ir21d) days. A single radiation dose of 30 Gy was used. Computed microtomography analyzed the cortical microarchitecture: cortical thickness (CtTh), bone volume (BV), total porosity (Ct.Po), intracortical porosity (CtPo-cl), channel/pore number (Po.N), fractal dimension (FD) and degree of anisotropy (Ct.DA). After scan, osteonal morphology was histologically assessed by means: area and perimeter of the osteons (O.Ar; O.p) and of the Haversian canals (C.Ar; C.p). Microtomographic analysis were performed by ANOVA, followed by Tukey and Dunnet tests. Osteon morphology analyses were performed by Kruskal-Wallis, and test Dunn's. Cortical thickness was significant difference (p<0.010) between the NIr and irradiated groups, with thicker cortex at Ir7d (1.15±0.09). The intracortical porosity revealed significant difference (p<0.001) between irradiated groups and NIr, with lower value for Ir7d (0.29±0.09). Bone volume was lower in Ir14d compared to control. Area and perimeter of the osteons were statistically different (p<0.0001) between NIr and Ir7d. Haversian canals also revealed lower values (p<0.0001) in Ir7d (80.57±9.3; 31.63±6.5) compared to NIr and irradiated groups. Cortical microarchitecture was affected by radiation, and the effects appear to be time-dependent, mostly regarding the osteons morphology at the initial days. Cortex structure in Ir21d revealed similarities to control suggesting that microarchitecture resembles normal condition after a period.


Resumo Com o objetivo de avaliar a microarquitetura óssea cortical e a morfologia dos osteons após irradiação, foram utilizados doze coelhos machos da Nova Zelândia. Os animais foram divididos: grupo controle (sem radiação-NIr); e 3 grupos irradiados, sacrificados após: 7 (Ir7d); 14 (Ir14d) e 21 (Ir21d) dias. Foi utilizada uma dose única de radiação de 30 Gy. A microtomografia computadorizada analisou a microarquitetura cortical: espessura cortical (CtTh), volume ósseo (BV), porosidade total (Ct.Po), porosidade intracortical (CtPo-cl), número de canal/ poro (Po.N), dimensão fractal (DF) e grau de anisotropia (Ct.DA). Após a varredura, a morfologia dos osteosn foi avaliada histologicamente por meio de: Área e perímetro do osteon (O.Ar; O.p) e dos canais de Havers (C.Ar; C.p). A análise microtomográfica foi realizada por ANOVA, seguida pelos testes de Tukey e Dunnet. As análises morfológicas do osteon foram realizadas por Kruskal-Wallis e testadas por Dunn. A espessura cortical foi diferente (p<0,010) entre os grupos controle e irradiados, com córtex mais espesso no Ir7d (1,15±0,09). A porosidade intracortical revelou diferenças significativas (p<0,001) entre os grupos irradiados e o controle, com menor valor para Ir7d (0,29±0,09). O volume ósseo foi menor no Ir14d em relação ao controle. Área e perímetro do osteon foi diferente (p<0,0001) entre o controle e Ir7d. Os canais haversianos também revelaram valores mais baixos (p<0,0001) em Ir7d (80.57±9.3; 31.63±6.5) em relação ao controle e demais grupos irradiados. A microarquitetura cortical é afetada pela radiação e os efeitos parecem ser dependentes do tempo, principalmente em relação à morfologia dos osteons nos dias iniciais. A estrutura cortical em Ir21d revelou semelhanças com o controle, sugerindo que a microarquitetura se assemelha à condição normal após um período.


Assuntos
Animais , Masculino , Coelhos , Osso Cortical/diagnóstico por imagem , Ósteon , Osso e Ossos , Porosidade , Fractais
18.
Dentomaxillofac Radiol ; 50(1): 20200255, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32706986

RESUMO

OBJECTIVES: To assess quantitatively the combined effect of exomass-related- and motion artefacts on voxel value parameters in cone beam CT (CBCT). METHODS: A cylindrical phantom was manufactured, containing 21 tubes filled with a radiopaque solution, allowing the inclusion of three titanium implants in the periphery to induce exomass-related artefacts. The phantom was mounted on a robot simulating 0.75-, 1.5-, and 3 mm movements (nodding/lateral rotation/tremor). CBCT images with/without exomass and with/without movements were acquired in duplicate in three units: Cranex 3Dx, Orthophos SL-3D, and X1 (with motion-artefact correction). A cylindrical volume of interest was defined in each tube and voxel value mean and standard deviation were assessed. For each CBCT volume, the 21 mean voxel values were averaged providing the overall mean voxel value (MVV), and the standard deviation (among the 21 values) was calculated providing overall voxel value inhomogeneity (VVI). The standard deviation from each of the 21 volumes-of-interest were averaged, providing overall image noise (IN). The effect of the diverse tested situations was inferred from a repeated-measures analysis of variance, followed by Sidak's test (α = 0.05). RESULTS: Overall, images acquired with exomass showed significantly (p ≤ 0.05) lower MVV, and higher VVI and IN. Motion artefacts aggravated exomass-related alterations. MVV and VVI were mostly affected by 3 mm nodding movements. Motion-artefact correction eliminated the deleterious effect of movement. CONCLUSIONS: CBCT voxel-value parameters are altered by exomass-related artefacts, and this finding is aggravated in the presence of motion artefacts. Motion-artefact correction effectively eliminated the deleterious impact of movement.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Movimento , Imagens de Fantasmas , Rotação
19.
J Oral Maxillofac Surg ; 78(12): 2184-2194, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32961127

RESUMO

PURPOSE: The aim of this preclinical study was to evaluate the healing of critical-sized defects (CSDs) in the calvarial bone of rats grafted with deproteinized bovine bone graft (DBB) and with a combination of hydroxyapatite (HA) and ß-tricalcium phosphate (TCP) and bisphosphonate treatment. MATERIALS AND METHODS: Eighty-four animals were randomly divided into 2 groups according to the type of solution administered: the control group (CTR, saline solution) and the test group (alendronate [ALD]; sodium alendronate-50 µg/kg/day). Medications were administered via oral gavage starting 15 days before the surgical procedure until the end of the experiment. A CSD (5 mm in diameter) was made in the calvaria of each animal, and the rats were randomly allocated to 3 subgroups according to the biomaterial used to fill the defect: coagulum, DBB, and HA/TCP. The animals were sacrificed 15 and 60 days after the surgical procedure (n = 7 animals/period/subgroup). Microcomputed tomography was used to evaluate the percentage of mineralized tissues (volume). The amount of newly formed bone and remaining bone substitute material in the calvaria were analyzed by histomorphometry. RESULTS: There were no differences between the CTR and ALD groups with regard to the volume of mineralized tissues. The DBB and HA/TCP subgroups of CTR animals presented a significant increase in newly formed bone compared with these subgroups of ALD animals after 60 days of healing. CONCLUSIONS: Collectively, our findings indicate that the use of oral ALD reduced bone formation in CSD in the calvaria of rats grafted with DBB and HA/TCP.


Assuntos
Substitutos Ósseos , Transplantes , Alendronato/farmacologia , Animais , Regeneração Óssea , Substitutos Ósseos/uso terapêutico , Fosfatos de Cálcio , Bovinos , Ratos , Crânio/cirurgia , Microtomografia por Raio-X
20.
Clin Oral Implants Res ; 31(10): 959-967, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32716570

RESUMO

OBJECTIVES: To evaluate graft remodelling according to the distance from the native bone in maxillary sinuses grafted with anorganic bovine bone (ABB). MATERIAL AND METHODS: Bilateral sinus grafting was performed in twenty patients with residual bone height <5 mm before implant placement. After 8 months, biopsy samples were harvested, and histomorphometric analysis was performed to examine bone formation according to the distance (in mm) from the native bone (sinus floor). In the grafted area, the percentages of new bone (NB), residual graft material (rABB), and soft tissue (ST) were evaluated. RESULTS: A total of 103 biopsy samples were evaluated, and the percentages of NB, rABB, and ST were 31.62 ± 9.85%, 18.94 ± 7.88%, and 49.41 ± 9.52%, respectively, in the 1st mm; 27.15 ± 9.83%, 23.33 ± 9.45%, and 49.53 ± 11.73%, respectively, in the 2nd mm; 23.61 ± 13.02%, 21.35 ± 11.08%, and 55.03 ± 16.14%, respectively, in the 3rd mm; and 21.67 ± 12.29%, 19.67 ± 10.28%, and 58.66 ± 12.46%, respectively, in the 4th mm. The 1st millimetre of the grafted area (closer to the native bone) presented a larger amount of NB than the other portions of the grafted areas and a smaller amount of rABB than the 2nd mm of the grafted area (p < .05). The amount of ST was larger in the 3rd and 4th mm of the grafted area than in the first 2 millimetres (p < .05). CONCLUSION: The distance from the native bone influences bone formation following maxillary sinus augmentation.


Assuntos
Substitutos Ósseos , Levantamento do Assoalho do Seio Maxilar , Animais , Transplante Ósseo , Bovinos , Humanos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/cirurgia , Osteogênese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA