RESUMO
OBJECTIVES: To assess the accuracy of three immunochromatographic rapid tests for salivary detection of immunoglobulin M (IgM) and immunoglobulin G (IgG) antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigens and the reliability of these tests comparing saliva with plasma samples. MATERIALS AND METHODS: Plasma and saliva samples from 62 patients diagnosed with coronavirus disease 2019 (COVID-19) and 20 healthy volunteers were assayed. IgM/IgG antibody against SARS-COV-2 was detected using three immunochromatographic rapid tests and compared with real-time reverse transcription-polymerase chain reaction (qRT-PCR). RESULTS: The tests' overall accuracy for detecting anti-SARS-CoV-2 antibodies ranged from 75.6 to 79.3 for saliva and 86.6-87.8 for plasma tests. The sensitivity of saliva and plasma tests increased with the severity of COVID-19 signs and symptoms. The chance of a positive plasma test in participants with a positive qRT-PCR test was 2.27 greater than a positive saliva test. CONCLUSIONS: Although rapid immunochromatographic tests are more accurate using plasma than saliva, which was expected considering its original use, our findings support the use of saliva as a straightforward supplementary method to assess seroconversion in patients with COVID-19, with important sensitivity and sensibility, especially in severe and critical cases.