Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Dent ; 143: 104897, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38395377

RESUMO

OBJECTIVES: This study aimed to evaluate the adhesive properties in dentine after the application of silver diamine fluoride (SDF) on carious dentine lesions immediately and after 2 years of water storage. METHODS: 96 human molars used were subjected to artificial dentine caries production, and then randomly divided into 12 experimental groups according to 1. application of an SDF solution (carious dentine lesion without SDF treatment [control], with 12 % silver diamine fluoride [SDF 12 %] or 38 % silver diamine fluoride [SDF 38 %]); 2. Universal adhesives (Clearfil Universal Bond Quick [CUQ] and Single Bond Universal [SBU]); 3. adhesive strategy (etch-and-rinse [ER] and self-etch [SE]). After restoration, the specimens were sectioned and submitted to the microtensile bond strength test (µTBS) and energy-dispersive X-ray spectrometry analysis (SEM/EDX). All tests were performed immediately and after 2 years of water storage. Data from the µTBS were analyzed using four-way ANOVA and Tukey's test (α = 0.05). RESULTS: Only the interaction of factors 'SDF' vs 'time' was significant (p = 0.03). After 2 years of storage, the groups where SDF was applied showed higher µTBS values compared to the control group. No significant decrease in µTBS values was observed for SBU when comparing immediate and 2-year results, but a significant reduction in µTBS values was observed after 2 years for CUQ. CONCLUSION: Independent of the adhesive strategy, the use of SDF may be a promising alternative to maintain the bonding of universal adhesives to carious dentinal lesions. CLINICAL SIGNIFICANCE: This study may clarify and support clinicians regarding the longevity of resin-based restoration in caries-affected dentine treated with silver diamine fluoride.


Assuntos
Bis-Fenol A-Glicidil Metacrilato , Colagem Dentária , Cárie Dentária , Compostos de Amônio Quaternário , Compostos de Prata , Humanos , Cimentos Dentários , Suscetibilidade à Cárie Dentária , Dentina , Água/química , Teste de Materiais , Resistência à Tração , Cimentos de Resina/farmacologia , Cimentos de Resina/química , Adesivos Dentinários/farmacologia , Adesivos Dentinários/química , Fluoretos Tópicos
2.
J Dent ; 140: 104800, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38056759

RESUMO

OBJECTIVE: This double-blind, split mouth randomized clinical trial aimed to assess the clinical performance of Clearfil Universal Bond Quick (CBUq) universal adhesive under different application times (no waiting and waiting) compared to Clearfil SE Bond adhesive in non-carious cervical lesions (NCCLs) over 18 months. METHODS: One hundred and eighty-three restorations were distributed randomly into three groups based on the adhesive system and waiting time: CUBq without waiting time (CUBq-NW), CUBq with a 20 s waiting time (CUBq-W), and CSE with a 20 s waiting time. After placement, restorations were evaluated after 18 months using the International Dental Federation (FDI) and United States Public Health Service (USPHS) criteria. Statistical analyses involved Friedman repeated measures analysis of variance and Wilcoxon tests, with a significance level set at 5 %. RESULTS: Over the 18-month period, no restorations were lost across the tested groups. Marginal adaptation evaluation indicated minor discrepancies in 21 restorations (8 CUBq-NW, 6 CUBq-W, and 7 CSE). There were no significant differences observed among the three groups following the 18-month clinical assessment (p > 0.05). Only two restorations showed marginal discoloration after 18 months (1 CUBq-NW and 1 CSE). CONCLUSIONS: The application of Clearfil Universal Bond Quick using either the "waiting" or "no-waiting" technique exhibited excellent clinical results in NCCLs during the 18-month follow-up period, demonstrating comparable performance to Clearfil SE Bond in all assessed outcomes. CLINICAL SIGNIFICANCE: The findings suggest that the new universal adhesive applied using the no-waiting technique demonstrates promising clinical performance when compared to conventional application methods. TRIAL REGISTRATION: ClinicalTrials.gov identifer RBR-69p7mpr.


Assuntos
Cimentos Dentários , Adesivos Dentinários , Cimentos Dentários/uso terapêutico , Resinas Compostas/química , Restauração Dentária Permanente/métodos , Cimentos de Resina/química , Boca , Colo do Dente/patologia , Adaptação Marginal Dentária
3.
Oper Dent ; 48(5): 500-512, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37503689

RESUMO

OBJECTIVES: To evaluate the absence of 2-hydroxyethyl methacrylate (HEMA) on the adhesive properties with enamel and dentin of universal adhesive systems containing 10-methacryloyloxydecyl dihydrogen phosphate (MDP). METHODS AND MATERIALS: One hundred and twelve caries-free third molars were used to test adhesion to dentin (n=64) and enamel (n=48). For each substrate, teeth were divided into eight experimental groups: four different adhesives each using two adhesive strategies. The adhesives used were: (1) Scotchbond Universal (SBU, 3M Oral Care, St Paul, MN, USA) as a HEMA-containing universal adhesive; (2) Gluma Bond Universal (GBU, Kulzer, Hanau, Germany); (3) Solare Universal Bond (SUB, GC, Tokyo, Japan); and (4) Zipbond Universal (ZIP, SDI, Victoria, Australia) as HEMA-free universal adhesives. The adhesive strategies used were etch-and-rinse (ER) and self-etch (SE). For dentin tests, the occlusal third of the crown of all teeth was removed and an adhesive protocol was applied. After completing the restoration, specimens were sectioned into bonded sticks (0.8 mm 2) and tested for microtensile bond strength (µTBS), in situ degree of conversion (DC), and nanoleakage (NL) by scanning electron microscopy. For enamel tests, teeth were sectioned into four parts (buccal, lingual, and proximal), and an adhesive protocol was applied. After completing the restoration, the specimens were tested for their microshear bond strength (µSBS). For in situ degree of conversion (DC) and nanoleakage (NL) evaluation of enamel, the specimens were sectioned in slices to be evaluated. The data for each substrate were subjected to two-way ANOVA and Tukey's test (α=0.05) for each property evaluated. RESULTS: The SBU and ZIP adhesives showed the highest µSBS, and DC (dentin and enamel) and lower NL (dentin) values compared to GBU and SUB (p=0.001). However, SBU showed better results in terms of µTBS and µSBS (SE strategy), and DC (dentin and enamel) than ZIP. Strategy ER presented higher values of µTBS and µSBS when compared to strategy SE (p=0.001), except for SBU. CONCLUSION: The effect of the absence of HEMA in commercial universal adhesive systems on enamel and dentin adhesive properties appears to be material-dependent.


Assuntos
Colagem Dentária , Cimentos Dentários , Cimentos Dentários/uso terapêutico , Cimentos Dentários/química , Dentina , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Metacrilatos/química , Resinas Compostas/química , Teste de Materiais , Resistência à Tração , Adesivos Dentinários/química
4.
Oper Dent ; 47(6): E253-E263, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36322381

RESUMO

PURPOSE: To evaluate the effect of application time and viscosity of meta-phosphoric acid (MPA) and ortho-phosphoric acid (OPA) on the push-out resin-dentin bond strength (PBS) and nanoleakage (NL) at the adhesive-root dentin interface. METHODS AND MATERIALS: Ninety-six roots of premolars were endodontically prepared and randomly assigned into groups according to the (i) acid (OPA and MPA), (ii) viscosity (gel and liquid), and (iii) application time (7 and 15 seconds). Fiber posts were cemented to the roots, which were then transversally sectioned into serial slices. The slices (cervical, medium, and apical) were subjected to PBS or NL. Analysis of the dentin etching pattern was performed using scanning electron microscopy (SEM). The PBS (MPa) and NL (%) data were subjected to three-way repeated-measures analysis of variance (ANOVA) and Tukey's test (α=0.05). RESULTS: The cross-product interaction was significant for both PBS and NL (p<0.001). No significant difference in the PBS was observed with the use of OPA compared to MPA (p>0.05). Higher PBS values were observed in the groups etched for 15 seconds compared to 7 seconds, regardless of the acid, viscosity, or root third (p<0.05). Lower NL was observed for MPA etching when compared to OPA etching (p<0.05), and these values were not affected by increasing the application time or acid viscosity (p>0.05). A more pronounced etching pattern was observed with OPA than MPA regardless of the acid viscosity. CONCLUSION: The use of 40% meta-phosphoric acid promoted adequate bond strength without increasing dentin demineralization or void spaces in the hybrid layer.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cavidade Pulpar , Dentina , Adesivos Dentinários/química , Teste de Materiais , Ácidos Fosfóricos/farmacologia , Cimentos de Resina/química , Viscosidade
5.
Oper Dent ; 47(4): 412-424, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35917253

RESUMO

OBJECTIVES: This study evaluated the influence of irradiance/exposure time on the Knoop hardness (KHN) and polymer cross-linking density (PCLD), as well as microtensile bond strength (µTBS), nanoleakage (NL), and in situ degree of conversion (DC) of universal adhesives. METHODS AND MATERIALS: Two universal adhesive systems, Clearfil Universal Bond Quick (CUQ) and Scotchbond Universal Adhesive (SBU), were light-cured using various irradiance/exposure times: 1400 mW/cm2 for 5 s (1400*5); 1400 mW/cm2 for 10 s (1400*10); 3200 mW/cm2 for 5 s (3200*5); and 3200 mW/cm2 for 10 s (3200*10). Adhesive disks from each group were used to measure PCLD by KHN. One hundred and twenty-eight human molars were randomly assigned to 16 groups according to the following variables: adhesive system vs adhesive strategies vs radiance/exposure times. After restoration, specimens were sectioned into resin-dentin sticks and tested for µTBS, NL, and DC. The data from PCLD (%), KHN, µTBS (MPa), NL (%), and DC (%) data were subjected to ANOVA and Tukey's test (α=0.05). RESULTS: Significant reductions in KHN, µTBS, and DC (p=0.00001) values and an increase in NL and PCLD (p=0.00001) values were observed for 3200*10 when compared with other groups. Higher KHN, µTBS, and DC (p=0.000001) values were observed for 3200*5 in comparison with the other groups. The 1400*5 (7 J/cm2) and 1400*10 (14 J/cm2) groups showed intermediate values (p=0.000001). CONCLUSION: Although similar results in terms of hardness, polymer cross-linking density and nanoleakage were observed when 5 seconds at 3200 mW/cm2 and 10 seconds at 1400 mW/cm2 groups were compared, the use of higher irradiance (3200 mW/cm2) for only 5 seconds showed better results in terms of bond strength and degree of conversion for both universal adhesives to dentin. The prolonged exposure time (10 seconds) at the higher irradiance (3200 mW/cm2) showed the worst results.


Assuntos
Colagem Dentária , Infiltração Dentária , Adesivos , Resinas Compostas/química , Cimentos Dentários/química , Dentina , Adesivos Dentinários/química , Humanos , Teste de Materiais , Cimentos de Resina/química , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA