Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Atten Disord ; 24(3): 447-455, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-30526190

RESUMO

Objective: This study evaluated the hypothesis that methylphenidate immediate release (MPH-IR) treatment would improve Default Mode Network (DMN) within-connectivity. Method: Resting-state functional connectivity of the main nodes of DMN was evaluated in a highly homogeneous sample of 18 drug-naive male adult participants with ADHD. Results: Comparing resting-state functional connectivity functional magnetic resonance imaging (R-fMRI) scans before and after MPH treatment focusing exclusively on within-DMN connectivity, we evidenced the strengthening of functional connectivity between two nodes of the DMN: posterior cingulate cortex (PCC) and left lateral parietal cortex (LLP). Conclusion: Our results contribute to the further understanding on how MPH affects functional connectivity within DMN of male adults with ADHD and corroborate the hypothesis of ADHD being a delayed neurodevelopmental disorder.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade , Metilfenidato , Adulto , Transtorno do Deficit de Atenção com Hiperatividade/diagnóstico por imagem , Transtorno do Deficit de Atenção com Hiperatividade/tratamento farmacológico , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Giro do Cíngulo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Metilfenidato/farmacologia , Metilfenidato/uso terapêutico
2.
Clin Nucl Med ; 36(8): 656-60, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21716015

RESUMO

Attention deficit/hyperactivity disorder (ADHD) is one of the most frequent behavioral problems in school-age children. Although the etiology remains unclear, the involvement of the dopaminergic system has been suggested by genetic studies that report an overexpression of the dopamine transporter (DAT) gene. In spite of these abnormalities being directly related to the decrease of dopamine (DA) in the striatum (STR), abnormalities in brain perfusion have also been observed in cortical-subcortical structures. Functional neuroimaging studies have suggested that the DA concentration may cause changes in the cerebral blood flow (CBF). The objective of our study was to evaluate the relationship between DAT density in STR and cortical-subcortical impairment in CBF. Based on the hypothesis that there is a correlation between DA availability and brain perfusion, we postulated that individuals with ADHD, with a higher DAT density in the basal ganglia, will have lower perfusion in the fronto-striatal-cerebellar networks. We used Tc-99m TRODAT-1 SPECT to measure DAT density and Tc-99m ECD SPECT to assess brain perfusion. Ten adolescents diagnosed with ADHD by Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria were investigated. Analysis with Statistical Parametric Mapping 5 corrected for multiple comparisons, using small volume correction, showed a significant negative correlation between the DAT density in the STR and CBF in the cingulate gyrus, frontal lobe, temporal lobe, and cerebellum (pFDR <0.01). Our findings suggest that higher DAT density in the STR was associated with a decrease in the regional CBF in the cortical and subcortical attention network.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade/metabolismo , Transtorno do Deficit de Atenção com Hiperatividade/fisiopatologia , Circulação Cerebrovascular , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Adolescente , Transtorno do Deficit de Atenção com Hiperatividade/diagnóstico por imagem , Gânglios da Base/irrigação sanguínea , Gânglios da Base/diagnóstico por imagem , Gânglios da Base/metabolismo , Cisteína/análogos & derivados , Dopamina/metabolismo , Humanos , Masculino , Neostriado/irrigação sanguínea , Neostriado/diagnóstico por imagem , Neostriado/metabolismo , Compostos de Organotecnécio , Tomografia Computadorizada de Emissão de Fóton Único , Tropanos , Adulto Jovem
3.
Nucl Med Commun ; 30(7): 565-8, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19424099

RESUMO

AIM: To simulate the effects of previous wide cutaneous melanoma excision in sentinel lymph node (SLN) biopsy feasibility through a change in the radiotracer injection site. MATERIALS AND METHODS: Thirty-three patients with cutaneous melanoma underwent two preoperatory lymphoscintigraphic studies. In the first, the radiopharmaceutical was injected intradermally 0.3 cm away from the lesion/scar. Dynamic images were acquired to find the SLN. On the following day, the procedure was repeated with the radiopharmaceutical injected 1 cm farther from the previous injection sites. The number of lymph nodes and sites of drainage were compared with the findings of the first study. All the patients underwent SLN biopsy using a gamma probe and patent blue. RESULTS: Seventy-five SLNs were identified with radiopharmaceutical injected at 0.3 cm from the lesion versus 82 SLNs when injected at 1.3 cm. All lymph nodes visualized with close injection were identified with the farther injection. Twenty-seven (81%) patients presented the same number and location of SLNs. Six (19%) patients presented more SLNs with the expanded technique, three patients in the same basin and three in a new lymph node station. All metastatic SLNs were harvested by the two injection techniques. CONCLUSION: The value of the SLN biopsy in patients with cutaneous melanoma is maintained even after the primary lesion has been removed with a margin of up to 1 cm. Some patients might show an increased number of SLNs and some might show drainage to additional lymph node stations.


Assuntos
Melanoma/patologia , Melanoma/cirurgia , Biópsia de Linfonodo Sentinela , Neoplasias Cutâneas/patologia , Estudos de Viabilidade , Feminino , Humanos , Injeções , Metástase Linfática/diagnóstico por imagem , Masculino , Melanoma/diagnóstico por imagem , Estadiamento de Neoplasias , Traçadores Radioativos , Cintilografia , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/cirurgia
4.
Nucl Med Commun ; 26(12): 1081-6, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16264354

RESUMO

OBJECTIVE: To describe the reproducibility of the sentinel lymph node technique in patients with prostate cancer and verify if there is improved accuracy over modified lymphadenectomy. MATERIAL AND METHODS: Twenty-three patients with biopsy proven prostate cancer were enrolled in this study. Lymphoscintigraphy was performed after the transrectal administration of Tc sulfur colloid guided by ultrasound, with one injection in each prostate lobe. Images were obtained 15 and 180 min after injection. Sentinel lymph node was harvested during surgery using a gamma probe, followed by extended lymphadenectomy. RESULTS: The mean age of the patients in this study was 66 years. An average of 3.36 sentinel lymph nodes was found for each patient. Radioactive lymph nodes were identified by the gamma probe in 21 out of 23 patients. In one of the patients there was no radiopharmaceutical migration from the injection site and in another the sentinel lymph node was visualized by lymphoscintigraphy but was not found during surgery. Three patients had lymph node metastasis; in one of these patients the sentinel lymph node was the only positive node and was found outside the modified lymphadenectomy region (obturator fossa and the external iliac). CONCLUSION: Sentinel lymph node biopsy in prostate cancer adds important information to the staging of patients, not always attained through the lymphadenectomy restricted to the obturator fossa and external iliac. Such information is essential for the choice of the best treatment to be applied.


Assuntos
Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Biópsia de Linfonodo Sentinela/métodos , Idoso , Biópsia , Humanos , Excisão de Linfonodo , Linfonodos/patologia , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Biópsia de Linfonodo Sentinela/instrumentação , Tecnécio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA